Job Performance Requirement 17-2
Conventional Forcible Entry—Door Swinging Toward
the Forcible Entry Team
JPR 17-2A
A Check the door to determine swing; the number, type, and location of locking devices; and the
type of door frame and hinges.
JPR 17-2B
B Create a gap between the door and jamb by driving the adz or fork end of the Halligan tool
between the door and frame 6 inches above or below the lock.
JPR 17-2C
C On tight doors, the gap maybe started with the fork end.
JPR 17-2D
D If door is tight, work tool up and down to open up gap.
JPR 17-2E
E Set the tool by driving the adz or forkend past the door around the doorstop.
JPR 17-2F
F This inside view showshow the adz is set.
JPR 17-2G
G Force the door by pulling thetool away from the door.