january, 20.pdf · glass kits: flush doors only. astragals: not available factory installed - field...

178
CURRIES Tech Manual Door Section Revised January, 2020

Upload: others

Post on 18-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

CURRIES Tech Manual

Door Section

Revised

January, 2020

Page 2: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

iIndex

Door Technical DataAugust, 2018

DESCRIPTION PAGE(S)

2-1/4” Thick Door .......................................................................................................................137 Astragals

Flat ......................................................................................................................................89“h” Type ...............................................................................................................................125Z Type ...................................................................................................................................90

Behavioral Healthcare Patient Room Access Door .......................................................................171 Bevels ...................................................................................................................................26-27

Bi-Fold Doors ..............................................................................................................................124Bottom (Semi-mortise) .................................................................................................................95Caps (Flush) ..............................................................................................................................31-32

Clearances ...............................................................................................................................24-25Construction Type (Series) 607 .....................................................................................................................................1-2 707 .......................................................................................................................................3

707 Honeycomb Core ...........................................................................................................162707 Stainless Steel ................................................................................................See Specialty Section

727 .......................................................................................................................................4 747 .......................................................................................................................................6

747 Stainless Steel .................................................................................................See Specialty Section747 Temperature Rise ..........................................................................................................170767 Stile and Rail Door Construction .................................................................................133-134777 Trio ................................................................................................................................161777 Trio-E ............................................................................................................................164797 Mercury Door .................................................................................................................165

847 ...................................................................................................................................10-14 857 ...................................................................................................................................15-19

Bullet Resistant Door and Frame .............................................................................See Specialty SectionSTC Quiet Noise Door .............................................................................................See Specialty SectionLead-Lined Door and Frame ...................................................................................See Specialty SectionWater Resistant Door and Frame.............................................................................See Specialty SectionAttack Resistant Door .............................................................................................See Specialty SectionForced Entry Bullet Resistant Door and Frame ........................................................See Specialty SectionFlood Resistant Door and Frame .............................................................................See Specialty Section

CURRIStain Door .........................................................................................................................125Dutch Doors .................................................................................................................................40Dutch Door Shelves ..................................................................................................................41-42Edge Seams ................................................................................................................................28End Channels ...............................................................................................................................29Face Types 1 & 2 (old style) .......................................................................................... 44-47, 60-65, 71-72Face Types 9 & 10 (standard kit).............................................................................................138-160Glass - Factory Installed in Doors

Karalite Filmed and Karalite Laminated .................................................................................166FireLite NT and FireLite Plus .................................................................................................1671/4” Tempered .....................................................................................................................1681/4” Filmed Wire ..................................................................................................................1685/8” and 1” Insulated Glass ..................................................................................................169

Glass Sizes (Visible) ..................................................................................................................48-59Glass Moulding

Type 1 (old style) .......................................................................................................... 66-67, 73-75Type 2 (old style wide pocket) .............................................................................................75-76Type 3 (Custom) ..............................................................................................................73, 77, 79Type 4 (Custom) .................................................................................................................78-79Type 7 & 8 (Custom) .............................................................................................................127Type 11 ................................................................................................................................131Window Kit Pocket Sizes .......................................................................................................126

Page numbers are linked

Page 3: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

iiIndexDoor Technical Data

November, 2014

DESCRIPTION PAGE(S)

Hardware ElectroLynx System ...............................................................................................................129 Locations .............................................................................................................................35-39 Reinforcement - Preparation Closer/Holder ................................................................................................................91-92 Concealed Closer ..........................................................................................................93-94 Flush Bolts ..................................................................................................................120-121 Hinge Hinge Preparation, 10” Blank ...........................................................................................34 Standard Mortise ..............................................................................................................2 Surface Mounted .............................................................................................................20 Overmortise-double Mortise ..............................................................................................9 Locks Cylindrical ....................................................................................................................96-102 Cylindrical Lock - Deadlock .............................................................................................115 Deadlocks ...................................................................................................................116-117 Pocket ............................................................................................................................118 Exit Device Preparations Concealed Vertical Rod ...................................................................................................111 Mortise Exit .....................................................................................................................110 Rim Panic ...................................................................................................................108, 128 Rim Vertical Rod .....................................................................................................109, 114, 128 Mortise Lock .............................................................................................................. 103-106, 112-113 Unit .......................................................................................................................................107 Push - Pulls ...........................................................................................................................119 Strikes Deadlock Strikes ...........................................................................................................82-83 Electric Strikes ..............................................................................................................86-88 Lip Strikes.....................................................................................................................80-81 Open Back Strike ..........................................................................................................84-85 Surface Bolts .........................................................................................................................122 Pivots Top and Bottom ............................................................................................................22 Pivots Intermediate .................................................................................................................23 Pocket Pivot ............................................................................................................................21 Louvers (Size and Location) ......................................................................................................68-70 Non-Rated Door Louver .........................................................................................................163 Monorail Preparation....................................................................................................................43 Rabbit Edge .................................................................................................................................76 Replacement Door .......................................................................................................................33 Panels Hollow Metal - Labeled ...........................................................................................................30 Hollow Metal - Non-Labeled...................................................................................................30a Mineral Fibreboard - Labeled .................................................................................................30b Composite Core - Non-Labeled ..............................................................................................30c Pocket Door .................................................................................................................................29 Wicket Doors ..........................................................................................................................135-136

Page 4: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

1607 Door Construction

Door Technical DataOctober, 2009

L14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

18 GA. (1.2)TOP END CHANNEL

POLYSTYRENE CORE

16 GA. (1.4)LOCK CHANNEL(WITH 1/2” (12.7)LEG LENGTH)

LOCK PREPARATION

18 GA. (1.2)BOTTOM END CHANNEL

20 GA. (0.9) & 18 GA. (1.2) SKINS(C.R.S. ONLY)

FACE SKINSBONDED TO CORE

14 GA. (1.9) HINGE CHANNEL(WITH 1/2” (12.7) LEG LENGTH)

Page 5: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

2607 Door SpecificationsDoor Technical Data

March, 2011

LNOTES:THICKNESS: 1-3/4” (44.5) ONLY!HANDING: Non-handed only. (square edges)EDGE: “S” type only.WIDTH: 2’0” (609.2) to 4’0” (1219.2), standard size increments only.HEIGHT: 6’8” (2032), 7’0” (2133.6), 7’2” (2184.4), and 8’0” (2438.4) onlyDOOR CLEARANCES: Standard – 1/8” (3.1) top, 3/8” (9.5) and 5/8” (15.8) bottom, 3/32” (2.3) hinge edge, 1/8” (3.1) lock edge.HARDWARE PREPARATIONS: Locks: Cylindrical – G2, G2B, G2EO Cylindrical deadlock – G16 Mortise – G3, G3EO (edge only), G3AEO (edge only), G3ARO (reinforce only). Strikes: E1B (Cut lip on strike in field) Flushbolt: H1, H1HO Surface Bolt: SB Push-Pull Reinf: G18 Hinges: 4-1/2” (114.3) x 4-1/2” (114.3) x .134” (3.4) Thickness and .180” heavy weight – 1/4” (6.3) backset. Panic Devices: G11 (rim exit), G11A (surface vertical rod), both reinforce only. Closer: CLGLASS KITS: Flush doors only.ASTRAGALS: Not available factory installed - field installation only.Hinge and lock locations are SDI manufacturers standard locations.

Steel Top/Bottom Filler Cap Hinge Edge

L L(Optional)20 GA. (.9) Galvanealed

COUNTERSINK #6–20SELF TAPPING SCREW.

CAP NOTCHED AT BOTH ENDS TO FIT HINGE AND LOCK CHANNELS.

SCREW APPLIED

DOOR SKIN MORTISED FORHEAVY WEIGHT NONHANDED4-1/2” (114.3) HINGE

18 GA. (1.2) HINGE FILLER HOLE PATTERN SIZED FOR 4-1/2” (114.3) HINGE

PROVIDED WITH DOOR

END VIEW

Page 6: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

3707 Door Construction

Door Technical DataFebruary, 2010

L14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

POLYSTYRENE COREURETHANE (OPTIONAL)

14 GA. (1.9)LOCK CHANNEL

LOCK PREPARATIONAS REQUIRED

16 GA. (1.4)BOTTOM END CHANNEL

20 GA. (0.9) - 14 GA. (1.9)FACE SKINS

BONDED TO CORE

14 GA. (1.9) STANDARDHINGE CHANNEL

12 GA. (2.6) SPECIAL ORDER

NOTE: SEE PAGE 162 FOR HONEYCOMB OPTION

3/8” AND 5/8” (15.8) UNDERCUT ONLY!

Page 7: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

4727 Door ConstructionDoor Technical Data

March, 2015

L 250˚F Temperature Rise Rating450˚F Temperature Rise Rating

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

12 GA. (2.6)TOP END CHANNEL

TEMPERATURE RISECOREBOARD

14 GA. (1.9)LOCK CHANNEL

LOCK PREPARATIONAS REQUIRED

16 GA. (1.4)BOTTOM END CHANNEL

18 GA. (1.2) AND 16 GA. (1.4)FACE SKINS

BONDED TO CORE

12 GA. (2.6) STANDARDHINGE CHANNEL

Page 8: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

5Notes

Door Technical Data

Page 9: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

6747 Door ConstructionDoor Technical Data

September, 2014

12 GA. (2.6)HINGE CHANNEL

16 GA. (1.4)BOTTOM END CHANNEL

A STEEL STIFFENED DOOR DESIGN IS AVAILABLE WITH A 450˚ TEMPERATURE RISE FIRE RATING ON PAGE 169.

22 GA. (.75) RIBS STANDARD20 GA. (.9), 18 GA. (1.2), 16 GA. (1.4)

(OPTIONAL)

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

FIBERGLASSINSULATION

14 GA. (1.9)LOCK CHANNEL

LOCK PREPARATIONAS REQUIRED

18 GA. (1.2), 16 GA. (1.4)OR 14 GA. (1.9) FACE SKINS

SPOT WELDED TO RIBSAT 6” (152) MAX. SPACING

RIBS WELDED TOGETHER AT ENDS

RIB PROFILE MAY VARY DEPENDING ON STIFFENER APPLICATION AND GAUGE.

6” (152) MAXIMUM SPACING

Page 10: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

7Notes

Door Technical Data

Page 11: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

8Hinge Channel ReinforcementDoor Technical Data

April, 2002

L

CONTINUOUS HINGE CHANNEL14 GA. (1.9) STANDARD12 GA. (2.6) SPECIAL ORDER - STANDARD AS NOTED PER DOOR SERIES

4-1/2” HINGE ONLY ULTIMA SHIM STANDARD FOR 4-1/2” HINGE STANDARD AND HEAVYWEIGHT

SCREW HOLES ARE EXTRUDED TO PROVIDE THREAD DEPTH EQUAL TO 10 GA. (3.4) PLATE (14 GA. (1.9))3/16” (4.8) PLATE (12 GA. (2.6))

1/4”(6.4)

SIZE AND TAPPER TEMPLATE

CONTINUOUS HINGE CHANNEL14 GA. (1.9) STANDARD12 GA. (2.6) SPECIAL ORDER - STANDARD AS NOTED PER DOOR SERIES

SIZE AND TAPPER TEMPLATE

HANDED - A BEVEL “ULTIMA”

NON HANDED - B BEVEL - “ULTIMA”

4-1/2” HINGE ONLY

HINGE PREPARATIONS OTHER THAN 4-1/2” ARE SIZE AND TAP PER TEMPLATE.

Page 12: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

9Over Mortise and Double Mortise Hinges on Doors

Door Technical DataApril, 2002

.268 (6.8) DEEP

HINGES SURFACE APPLIED TO FRAME

.226 (5.7) DEEP

STANDARD MORTISE IN FRAME .134 (3.4)

.360 (9.1) DEEP

HINGES SURFACE APPLIED TO FRAME

.292 (7.4) DEEP

HINGES SURFACE APPLIED TO FRAME

.234 (5.9) DEEP

STANDARD MORTISE IN FRAME .146 (3.7)

.380 (9.7) DEEP

HINGES SURFACE APPLIED TO FRAME

4-1/2” (114.3) STANDARD WEIGHT (.134) (3.4)DOUBLE MORTISE

HINGESS.D.M.

4-1/2” (114.3) HEAVY WEIGHT (.180) (4.6)OVER MORTISE

HINGESH.O.M.

4-1/2” (114.3) HEAVY WEIGHT (.180) (4.6)DOUBLE MORTISE

HINGESH.D.M.

5” (127) STANDARD WEIGHT (.146) (3.7)DOUBLE MORTISE

HINGESS.D.M.

5” (127) HEAVY WEIGHT (.190) (4.8)OVER MORTISE

HINGESH.O.M.

5” (127) HEAVY WEIGHT (.190) (4.8)DOUBLE MORTISE

HINGESH.D.M.

NOTE: ULTIMA 4-1/2” (114.3) HINGE GIVES THE OPTION OF STANDARD OR HEAVY WEIGHT.

Page 13: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

10847 Security Door ConstructionDoor Technical Data

April, 2002

L

INSULATION BETWEENRIBS 1 LB. (.45) DENSITY

LOCK PREPARATION AS REQUIRED

FACE SHEETS (STANDARD)14 GA. (1.9)

RIBS, SPOT WELDED TO EACH SKIN AT 4” (102) MAX. SPACING 18 GA. (1.2) AND WELDED FULL

WIDTH ON ENDS.

RIBS WELDED TOGETHER AT ENDS

1-3/4” (35)

LOCK CHANNEL REINFORCING14 GA. (1.9)

1/8” IN 2” BEVEL(3.2) IN (50.5)

TOP AND BOTTOM END CHANNEL16 GA. (1.4)

CLOSER REINFORCEMENT (OPTIONAL)12 GA. (2.6)

12 GA. (2.6) HINGE CHANNEL REINFORCING1/8” IN 2” BEVEL.

(3.2) IN (50.8)

*�*�*�*�*�

4” (102) MAX. SPACING

Page 14: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

11847 Security Door Rib Construction

Door Technical DataApril, 2002

L

NOTE: RIBS ARE WELDED TOGETHER FULL WIDTH ON ENDS OF RIB.

*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�

14 GA. (1.9) FACE SHEET

RIBS WELDED TO FACE SHEETS4” (101.6) ON CENTER MAX.

18 GA. (1.2) RIBS STANDARD.

12 GA. (2.6) HINGE CHANNEL EXTRUDED AND TAPPED FOR HINGES

14 GA. (1.9) LOCK CHANNEL

4” (102)MAX.

1-3/4”(44.5)

Page 15: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

12847 Security Door Hinge Channel ReinforcementDoor Technical Data

April, 2002

L

SIZE AND TAPPER TEMPLATE

1/4” (25.6)

1-3/4” (44.5)

(STD) TAP 12-24(OPTIONAL) TAP 1/4-20

EXTRUDED TO PROVIDETHREAD DEPTH EQUIVALENT

TO 3/16” (4.8) PLATE

HOLE FOR PRISON SAFETY FEATURE (PSF)

STUD (OPTIONAL)

CONTINUOUSHINGE CHANNEL

12 GA. (2.6)

Page 16: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

13847 Standard Hardware Location

Door Technical DataApril, 2002

LSTANDARD HINGE BACKSET

“G” BEVEL DOOR SHOWN

1-15/16”(49.3)

1/16” (1.6) CLEARANCE

1/4” (6.4)

1-3/4” (44.5)

1/8” (3.2) REVEAL

1/8” (3.2)

5/8” (15.9)

A

B

C

D

CLCLCLCL

40”(1017.1)

42”(1068)

PERTEMPLATE

48”(1220.6)

A = DEADLOCK STRIKE HEIGHTB = HOSPITAL LATCH STRIKE AND PUSH PLATE HEIGHTC = PUSH BAR AND PULLD = STRIKE HEIGHT

STRIKE LOCATIONS

Page 17: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

14847 Top (Bottom Optional) Flush CapDoor Technical Data

April, 2002

16 GA. (1.4) STANDARD

NOTCHED AT BOTH ENDS TO FIT HINGE AND LOCK CHANNELS.

ARC WELDS

FILL AND FINISH SMOOTH. (OPTIONAL)

WELDED (STANDARD)

Page 18: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

15857 Security Door Construction

Door Technical DataNovember, 2004

*�*�*�

12 GA. (2.6) HINGE CHANNEL REINFORCING 1/8” IN 2” BEVEL.(3.2) IN (50.8)

CLOSER REINFORCEMENT (OPTIONAL) 12 GA. (2.6).

TOP AND BOTTOM END CHANNEL 14 GA. (1.9)

INSULATION BETWEEN RIBS1 LB. (.45)

LOCK CHANNEL REINFORCING14 GA. (1.9)1/8” IN 2” BEVEL(3.2) IN (50.5)

LOCK PREPARATIONAS REQUIRED

2” (50.8)

FACE SHEETS (STANDARD)14 GA. (1.9)

RIBS, SPOT WELDED TO EACH SKIN ON 4” (101.6) CENTERS AND FULL WIDTH

ON ENDS. 18 GA. (1.2)

RIBS WELDED TOGETHER AT ENDS

16 GA. (1.4) WELDED TOP CAP

2” DOOR L

Page 19: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

16857 Security Door Rib Cross SectionDoor Technical Data

April, 2002

L

*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�*�

14 GA. (1.9)FACE SKINS

14 GA. (1.9) LOCK CHANNEL

RIBS WELDED TO FACE SHEETS 4” (101.6) ON CENTER MAX18 GA. (1.2) RIBS STANDARD

12 GA. HINGE CHANNEL PUNCHED AND PIERCED

2”(50.8)

4” (101.6)MAX.

NOTE: RIBS ARE WELDED FULL WIDTH ON ENDS

2” DOOR

Page 20: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

17857 Security Hinge Channel Reinforcement

Door Technical DataApril, 2002

L

CONTINUOUS HINGE CHANNEL12 GA. (2.6)

SIZE AND TAPPER TEMPLATE

1/2” (12.7)

2” (50.8)

(STD) TAP 12-24(OPTIONAL) TAP 1/4-20

EXTRUDED TO PROVIDE THREAD DEPTH EQUIVALENT TO

3/16” (4.8) PLATE

HOLE FOR PRISON SAFETY FEATURE (PSF) STUD (OPTIONAL)

2” DOOR

Page 21: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

18857 Standard Hardware LocationsDoor Technical Data

April, 2002

L STANDARD HINGE BACKSET

2-3/16”(55.6)

1/8” (3.2) CLEARANCE

1/2” (12.7)

2” (50.8)

1/16” (1.6) REVEAL

1/8” (3.2)

5/8” (15.9)

A

B

C

D

CLCLCLCL

40”(1017.1)

42”(1068)

PERTEMPLATE

48”(1220.6)

A = DEADLOCK STRIKE HEIGHTB = HOSPITAL LATCH STRIKE AND PUSH PLATE HEIGHTC = PUSH BAR AND PULLD = STRIKE HEIGHT

5/8” (15.9)

STRIKE LOCATIONS

2” DOOR

2” DOOR

“G” BEVEL DOOR SHOWN

Page 22: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

19857 Top (Bottom Optional) Flush Channel

Door Technical DataApril, 2002

L

16 GA. (1.4) STANDARD

CAP NOTCHED AT BOTH ENDS TO FIT HINGE AND LOCK CHANNELS.

ARC WELDS

FILL AND FINISH SMOOTH. (OPTIONAL)

WELDED (STANDARD)

2”(50.8)

****

2” DOOR

Page 23: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

20Surface Mounted Hinge ReinforcementDoor Technical Data

April, 2002

L

NOTE: DOOR SIZE REQUIREMENTS DETERMINED BY HINGE MANUFACTURERS TEMPLATES AND MOUNTING INSTALLATION.

CONTINUOUS GEAR HINGE APPLICATIONS(CLEARANCE VARIES PER MANUFACTURER)

CLEARANCE:11/32” (8.7) PLUS STANDARDLOCKSIDE CLEARANCE

CLEARANCE:NONE REQUIRED1-5/8” (41.3) MINIMUM FRAME FACEREQUIRED PLUS 3/16” (4.8)ROTATIONAL CLEARANCE

12 GA. (2.6)CONTINUOUS HINGE

CHANNEL FULL HEIGHTOF DOOR

4-1/8”(104.8)

CONTINUOUS LOCK CHANNEL

USE FOR SURFACE APPLIED BUTT AND CONTINUOUS HINGES WITHOUT THE NEED FOR THRU-BOLTS.

Page 24: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

21Door Pocket PivotDoor Technical Data

April, 2002

L12 GA. (2.6) CONTINUOUS HINGE CHANNEL

EXTRUDED AND TAPPED PER TEMPLATESCREW HOLES ARE EXTRUDED TO PROVIDE THREAD DEPTH EQUAL TO 3/16” (4.8)

Page 25: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

22Door Top and Bottom Pivot Preparation “D” BevelDoor Technical Data

April, 2002

L“D” BEVEL CONTINUOUS CHANNEL

7 GA. (4.5) REINFORCEMENT

SIZE AND TAP PER TEMPLATE

TOP PIVOT

PERTEMPLATE

PER TEMPLATE

“D” BEVELCONTINUOUS CHANNEL

7 GA. (4.5) REINFORCEMENT

PERTEMPLATE

PERTEMPLATE

SIZE AND TAP PER TEMPLATE

BOTTOM PIVOT

PERTEMPLATE

Page 26: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

23Door Intermediate Pivot Preparation “D” Bevel

Door Technical DataApril, 2002

L

NOTE: CURRIES PIVOTLOCATIONS ARE EQUALLY SPACED.

“D” BEVEL CONTINUOUS CHANNEL

SIZE AND TAP PER TEMPLATE

PER TEMPLATE

PERTEMPLATE

1-1/8” (34.9)

7 GA. (4.5) REINFORCEMENTPER PIVOT

PERTEMPLATE

PERTEMPLATE

10”(254)

Page 27: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

24Standard Door ClearancesDoor Technical Data

March, 2012

SINGLE PAIR

1/8” (3.2)

5/8” (15.9) *

1/8” (3.2)

*5/8” (15.9)

“A”BEVEL

“A”BEVEL

“A”BEVEL

3/32” (2.9) 3/32” (2.9)

3/32”(2.9)

3/32” (2.9)

WITHOUT ASTRAGAL

WITH “Z” ASTRAGAL

DOUBLE EGRESS (E )

3/16” (4.8)

3/32”(2.9)

3/32”(2.9)

1/8”(3.2)

3/32” (2.9)

3/32” (2.9)1/16” (1.6) A, D, & G BEVELS

* NOTE: The 5/8” (15.9) standard bottom undercut shown on the above drawings are for 1-3/4” (44.5) doors, 1-3/8” (34.9) doors have a 3/4” (19.1) standard bottom undercut.

1/8” (3.2)

5/8” (15.9) *

“A”BEVEL

“A”BEVEL

1/8” (3.2) NON HANDED “B” BEVEL

1/4” (6.4) NON HANDED “B” BEVEL

1/8” (3.2) NON HANDED “B” BEVEL3/16” (4.8) E AND F BEVELS

L

+

+ NOTE: E code (double opening) doors are oversize 1/16” from standard for double egress.

Doors ordered for other than CURRIES locations will get the standard undercut of the specified manufacturer.

Page 28: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

25857 Standard Door Clearances

Door Technical DataMarch, 2012

NET DOOR HEIGHT

NOMINALHEIGHT

1/8” (3.2)

5/8” (15.9) STD. UNDERCUT

SINGLE PAIR

FLOOR LINE

WITH “Z” ASTRAGALWITHOUT ASTRAGAL

3/32” (2.9) 3/16” (4.8) 3/32” (2.9)NET DOOR WIDTH NET DOOR WIDTH

NOMINAL OPENING WIDTH

3/32” (2.9) 1/8” (3.2) 3/32” (2.9)NET DOOR WIDTH NET DOOR WIDTH

NOMINAL OPENING WIDTH

SINGLE

3/32” (2.9)NET DOOR WIDTH

NOMINAL OPENING WIDTH

3/32” (2.9)

1/8” (3.2)

1/16” (1.6)

2”

1/8” (3.2)IN 2” (50.8)BEVEL

3/32” (2.4)

2-3/16” (55.6)

2” DOOR L

Doors ordered for other than CURRIES locations will get the standard undercut of the specified manufacturer.

Page 29: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

26Bevels (Door Edge)Door Technical Data

April, 2002

SQUARE

SQUARE

1/8” IN 2” BEVEL(3.2) IN (50.8)

1/8” IN 2” BEVEL(3.2) IN (50.8)

1/8” IN 2” BEVEL(3.2) IN (50.8)

SQUARE

STANDARD DOOR BEVEL

DOOR BEVEL (NON-HANDED)POCKET DOOR, TRANSOM PANEL,

SIDELITE PANEL

SPECIAL DOOR BEVEL(DOUBLE BEVEL)

HINGE LOCK

HINGE LOCK

HINGE LOCK

“A” BEVEL

“B” BEVEL

1/8” IN 2” BEVEL(3.2) IN (50.8)WITH 1/4” (6.4) RADIUSLOW SIDE

1/8” IN 2” BEVEL(3.2) IN (50.8)

REQUIRED WITH ALL OFFSET PIVOT HARDWAREVERIFY ALL HARDWARE ADAPTABILITY

HINGE LOCK“D” BEVEL

“G” BEVEL

2-5/8” (66.8)RADIUS OR*HARDWARE WILL DETERMINE THE RADIUS

2-5/8” (66.8)RADIUS

RADIUS SHOULD MATCH HINGE EDGE

BULL NOSE BOTH ENDS (“N” OR “T” EDGE ONLY)REQUIRED WITH SOME DOUBLE ACTING HARDWARE

VERIFY ALL HARDWARE ADAPTABILITY

HINGE LOCK“E” BEVEL

2-5/8” (66.8)RADIUS SQUARE

BULL NOSE BOTH ENDS (“N” OR “T” EDGE ONLY)REQUIRED WITH DOUBLE ACTING HARDWARE

VERIFY ALL HARDWARE ADAPTABILITY

HINGE LOCK“F” BEVEL

L

Page 30: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

HINGE LOCK

HINGE LOCK

27Bevels (Door Edge)

Door Technical DataJanuary, 2010

L

HINGE LOCK“G” BEVEL

“A” BEVEL

“B” BEVEL

“D” BEVEL

HINGE LOCK

1/8” IN 2” BEVEL(3.2) IN (50.8)

1/8” IN 2” BEVEL(3.2) IN (50.8)

SQUARE

1/8” IN 2” BEVEL(3.2) IN (50.8)

1/8” IN 2” BEVEL(3.2) IN (50.8)

1/8” IN 2” BEVEL(3.2) IN (50.8)

WITH 1/4” (6.4) RADIUSLOW SIDE

SQUARE

SQUARE

OPTIONAL DOOR BEVEL (NON-HANDED & HANDED) SLIDING DOORS

REQUIRED WITH ALL OFFSET PIVOT HARDWARE VERIFY ALL HARDWARE ADAPTABILITY

OPTIONAL

OPTIONAL DOOR BEVEL

STANDARD DOOR BEVEL(DOUBLE BEVEL)

2” DOOR

847 - 857 - Security Door Bevels

HINGE LOCK“P” BEVEL 1/8” IN 2” BEVEL(3.2) IN (50.8)RECESSED HINGE EDGE

FOR POCKET PIVOTS

HINGE LOCK“Q” BEVEL SQUARERECESSED HINGE EDGE

FOR POCKET PIVOTS

Page 31: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

28Edge Seam Types “S” - “N” - “T”Door Technical Data

December, 2014

LVisible Edge Seam Types “S”

Filled Flush Edge Seam Type “N”

Flush Edge Seam Welded and Filled Type “T”

1. Skins are spot welded to hinge and lock channels

2. Spot welds are filled and ground smooth

1. Skins are spot welded to hinge and lock channels

2. Spot weld seams at stress points and between each “S” weld location

3. All welds and seams are filled and ground smooth

1. Skins are spot welded to hinge and lock channels

NOTE: NOT AVAILABLE ON 20 GAUGE DOORS

2. Continuously weld seam full height of edges

3. All welds and seams are filled and ground smooth

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

**

*

*

*

* *

*

**

*

*

*

* *

*

**

*

* **************************************************

**

****

**

****

*

Page 32: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

29End Channels and Pocket Door

Door Technical DataApril, 2002

L

**

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

*

*

*

*

*

*

Standard Top/Bottom End Channels

Pocket Door

**

*

*

*

*

*

*

*

*

*

*

L

**

*

*

*

*

*

*

*

*

*

*

SPOT WELDS2” (50.8) FROM ENDS6” (152.4) ON CENTER

WEEP HOLES

* 3/4” (19.1) FOR 1-3/4” (44.5) DOOR15/16” (23.8) FOR 1-3/8” (34.9) DOOR

* 3/4” (19.1) FOR 1-3/4” (44.5) DOOR15/16” (23.8) FOR 1-3/8” (34.9) DOOR

* MOST AUTOMATIC DOOR BOTTOMS REQUIRE SPECIAL DEPTH CHANNEL

**

*

*

*

*

*

*

*

*

*

*

BOTTOM CHANNEL16 GA. (1.4)

DOOR SKIN**

* *

*

*

*

*

*

*

*

*

*

*

TOP CHANNEL16 GA. (1.4)

DOOR SKIN

* *

“B” BEVEL BOTH EDGES SQUARE

NOMINAL DOOR WIDTHLESS STANDARD, UNDER SIZE

3’0” (914.4)

2’11” (889)

EXAMPLE

**

*

*

*

*

*

*

*

*

*

*

TOP OFDOOR

NOMINAL 3’0” (914.4) POCKET DOOR AND FRAME HAS A NET 2’11” (889) FRAME OPENING.

12 GA. (2.6) STANDARD OR 7 GA. (4.5) REINFORCEMENT AVAILABLE INSTALLED FULL WIDTH OF DOOR TOP CAP.

VERIFY HARDWARE HANGER ADAPTABILITY TO REINFORCEMENT AND FRAME OPENING

NOTE - CHANNEL GAUGE MAY VARY WITH DOOR SERIES

OPENFRAME

INSIDEDIMENSION

Page 33: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

30Hollow Metal Panels - Transom/Side Areas 1-3/4”Door Technical Data

September, 2010

L

WIDTH8’0” (2438)MAXIMUM

HEIGHT4’0” (1219.2)

MAXIMUM

TRANSOM PANELS

LABELED

SPECIFY USE OF PANEL AND LIST NOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1-3/4”(44.5) PANEL 707 OR 747 - 18, 16, OR 14 GA.

HORIZONTAL CHANNELS

“B” BEVEL BOTH EDGES SQUARE

NOTE: SEE PAGES 81 AND 82 IN LABEL SECTION FOR OVERSIZE TRANSOM PANEL CAPABILITIES. REFERENCE LABEL SECTION OF TECH DATA MANUAL FOR MAXIMUM SQUARE INCH SIZE REQUIREMENTS AND OTHER FIRE LABEL CAPABILITIES.

SIDE PANELS

SPECIFY USE OF PANEL AND LISTNOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1-3/4”(44.5) PANEL 707 OR 747 - 18, 16, OR 14 GA.

HEIGHT8’0” (2438)MAXIMUM

WIDTH4’0” (1219.2)

MAXIMUM

VERTICAL CHANNELS

“B” BEVEL BOTH EDGES SQUARE

TRANSOM PANEL INSTALLATION OPTIONS:

1. PANEL WELDED INTO FRAME2. PANEL INSTALLED WITH SCREWS3. PANEL INSTALLED WITH GLASS STOP 4. PANEL INSTALLED WITH SLIP-IN CHANNEL. SEE PAGE 134 IN THE FRAME SECTION (MUST NOTE ON BOTH DOOR AND FRAME ORDER)

Page 34: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

30AHollow Metal Panels - Transom/Side Areas 1-3/4”

and 1-3/8” ThickDoor Technical Data

September, 2010

L

WIDTH10’0” (3048)MAXIMUM

HEIGHT4’0” (1219.2)

MAXIMUM

TRANSOM PANELS

SPECIFY USE OF PANEL AND LIST NOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1-3/4”(44.5) PANEL 707 OR 747 - 20, 18, 16, OR 14 GA. 1-3/8” (34.9) PANEL 707 ONLY - 20, 18, 16, OR 14 GA.

HORIZONTAL CHANNELS

“B” BEVEL BOTH EDGES SQUARE

SIDE PANELS AND DOOR PANELS

SPECIFY USE OF PANEL AND LISTNOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1-3/4”(44.5) PANEL 707 OR 747 - 20, 18, 16, OR 14 GA.1-3/8” (34.9) PANEL 707 ONLY - 20, 18, 16, OR 14 GA.

HEIGHT10’0” (3048)MAXIMUM

WIDTH4’0” (1219.2)

MAXIMUM

VERTICAL CHANNELS

“B” BEVEL BOTH EDGES SQUARE

TRANSOM PANEL INSTALLATION OPTIONS:

1. PANEL WELDED INTO FRAME2. PANEL INSTALLED WITH SCREWS3. PANEL INSTALLED WITH GLASS STOP 4. PANEL INSTALLED WITH SLIP-IN CHANNEL. SEE PAGE 134 IN THE FRAME SECTION (MUST NOTE ON BOTH DOOR AND FRAME ORDER)

NON-LABELEDStandard Top/Bottom End Channels

Page 35: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

30BMineral Fibreboard Core Panel-Transom/Side Areas 1/2” ThickDoor Technical Data

September, 2010

L

WIDTH4’0” (1219.2)

MAXIMUM

PANEL INSTALLATION OPTIONS:

1. PANEL INSTALLED WITH GLASS STOP 2. PANEL INSTALLED INTO DOOR WINDOW KIT

WIDTH8’0” (2438)MAXIMUM

HEIGHT4’0” (1219.2)

MAXIMUM

TRANSOM PANELS

SPECIFY USE OF PANEL AND LIST NOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1/2” (12.7) PANEL MINERAL FIBREBOARD CORE20, 18, OR 16 GA. FACE SKINS

SIDE PANELS AND/OR DOOR PANELS

SPECIFY USE OF PANEL AND LISTNOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1/2” (12.7) PANEL MINERAL FIBREBOARD CORE20, 18, OR 16 GA. FACE SKINS

HEIGHT8’0” (2438)MAXIMUM

FRAMEAPPLICATION

DOOR APPLICATION

1/8” (3.2)MAXIMUM

NOTE: REFERENCE LABEL SECTION OF TECH DATA MANUAL FOR MAXIMUM SQUARE INCH SIZE CAPABILITIES FOR DOORS AND FRAMES.

1/8” (3.2)MAXIMUM

LABELED

Page 36: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

30CComposite Core Panels - Transom/Side Areas 3/8” to 1” Thick

Door Technical DataJanuary, 2011

WIDTH4’0” (1219.2)

MAXIMUM

TRANSOM PANEL INSTALLATION OPTIONS:

1. PANEL WELDED INTO FRAME2. PANEL INSTALLED WITH SCREWS3. PANEL INSTALLED WITH GLASS STOP

L

WIDTH10’0” (3048)MAXIMUM

HEIGHT4’0” (1219.2)

MAXIMUM

TRANSOM PANELS

SPECIFY USE OF PANEL AND LIST NOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1”(25.4) PANEL COMPOSITE CORE7/8” (22.2) PANEL COMPOSITE CORE3/4” (19.1) PANEL COMPOSITE CORE5/8” (15.9) PANEL COMPOSITE CORE1/2” (12.7) PANEL COMPOSITE CORE 3/8” (9.5) PANEL COMPOSITE CORE

20, 18, 16, AND 14 GA. FACE SKINS

SIDE PANELS AND/OR DOOR PANELS

SPECIFY USE OF PANEL AND LISTNOMINAL FRAME OPENING FOR CORRECT PANEL UNDERSIZING.

1”(25.4) PANEL COMPOSITE CORE7/8” (22.2) PANEL COMPOSITE CORE3/4” (19.1) PANEL COMPOSITE CORE5/8” (15.9) PANEL COMPOSITE CORE1/2” (12.7) PANEL COMPOSITE CORE 3/8” (9.5) PANEL COMPOSITE CORE

20, 18, 16, AND 14 GA. FACE SKINS

HEIGHT10’0” (3048)MAXIMUM

FRAMEAPPLICATION

DOOR APPLICATION

1/8” (3.2)MAXIMUM

NON-LABELED

1/8” (3.2)MAXIMUM

Page 37: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

30DNotesDoor Technical Data

September, 2010

Page 38: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

31Filler Caps

Door Technical DataDecember, 2013

Steel Top/Bottom Filler Cap

SCREW APPLIED

STANDARD 20 GA. (.9) GALVANEALED

COUNTERSINK #6–20 SELF TAPPING SCREW

CAP NOTCHED AT BOTH ENDS TO FITHINGE AND LOCK CHANNELS

END VIEWBOTTOM CAP

END VIEWTOP CAP

WELDED (OPTIONAL)

ARC WELDS

INSTALL CAP, WELD, GRIND, FILLED(OPTIONAL)

AVAILABLE FOR 1-3/4” (44.5)AND 1-3/8” (34.9) DOORS.

FILL AND FINISH SMOOTH CAPS ARE RECESSEDTO ALLOW FOR FILLAND FINISH

L

Page 39: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

32Snap-In Steel Top CapDoor Technical Data

April, 2002

L

INSTALLATION INSTRUCTIONS

1) PLACE ONE LEG OF THE TOP CAP 1/8” INTO THE THROAT OF THE END CHANNEL. PLACE A STRAIGHT BLADE SCREW DRIVER IN THE BEND RADIUS AT ONE END OF THE TOP CAP AS SHOWN. USING A HAMMER TAP ON THE SCREW DRIVER TO START THE TOP CAP INTO THE THROAT OF THE END CHANNEL. PROCEED BY INCREMENTS FROM ONE END OF THE TOP CAP ACROSS TO THE OPPOSITE END. CARE SHOULD BE TAKEN NOT TO FORCE THE TOP CAP.

2) BOTH LEGS OF THE TOP CAP SHOULD BE COMPLETELY STARTED INTO THE THROAT OF THE END CHANNEL. THE TOP CAP CAN NOW BE PUSHED INTO THE END CHANNEL. A RUBBER HAMMER MAY BE NECESSARY TO SEAT THE TOP CAP COMPLETELY INTO THE END CHANNEL.

3) THE TOP CAP IS DESIGNED TO BE FLUSH TO SLIGHTLY BELOW THE LEGS OF THE END CHANNEL.

TOP CAP

BOTTOM CAP

SCREWRECOMMENDED

END VIEW

Push

1)

2) 3)

AVAILABLE FOR 1-3/4” (44.5) DOORS ONLY.607 AND 707 SERIES WITH 14 GAUGE HINGE CHANNEL.

24 GA. (.6) GALVANEAL

Screwdriver

Page 40: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

33Replacement Door

Door Technical DataDecember, 2014

L

“S” EDGE ONLY

HINGE CHANNELPREPARATION

4-1/2” (114.3) NON-HANDED ULTIMA HINGE SHIM

MORTISE DOOR SKIN .230” (5.8) DEEP

NOTCH SKINS, DRILL AND TAP AS PER HINGE TEMPLATE707 FLUSH DOOR ONLY

4-1/2”(114.3)

10”(254)

OF MORTISE LOCK MAY VARY 2-1/2” (63.5)CL

G3AROMORTISE LOCK REINFORCEMENT

6’8” (2032) - 39-1/4” (997)7’0” (2133.6) - 43-1/4” (1098.6)7’2” (2184.4) - 45-1/4” (1149.4)

DOOR WIDTH CLEARANCE IS1/8” (3.2) AT LOCK EDGE,3/32” (2.4) AT HINGE EDGE.

OF REINFORCEMENTCL

40-5/8” (1031.9)

5/8” (15.9)

FINISHED FLOOR

6’8” (2032) - 9-3/8” (238.1)7’0” (2133.6) - 9-3/8” (238.1)7’2” (2184.4) - 9-3/8” (238.1)

6’8” (2032) - 39-1/2” (1003.3)7’0” (2133.6) - 41-1/2” (1054.1)7’2” (2184.4) - 42-1/2” (1079.5)

6’8” (2032) - 69-5/8” (1768.5)7’0” (2133.6) - 73-5/8” (1870)7’2” (2184.4) - 75-5/8” (1920.9)

6’8” (2032) - 79-1/4” (2013)7’0” (2133.6) - 83-1/4” (2114.6)7’2” (2184.4) - 85-1/4” (2165.4)

20” (508)CLOSER REINF.

14 GA. (1.9) LOCK CHANNEL

14 GA. (1.9) HINGE CHANNELWITH 12 GA. (2.6) BACKERON EACH OFFSET

LOCK REINF.

OPTIONAL

1/8” (3.2) FRAME OPENING

HINGE RAIL OFFSET IS 10” LONG AT EACH LOCATION

CL

CL

CL

14 GA. (1.9)CHANNEL REINFORCEMENT

12” (304.8)

4-3/4” (120.6)

Page 41: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

3410” Blank Hinge PreparationDoor Technical Data

April, 2002

L

• CAN BE USED FOR ANY SDI MEMBER HINGE LOCATION FOR THE FOLLOWING DOOR HEIGHTS:

6’8”, 7’0”, 7’2”, 8’0”, 10’0”.

• “A” AND “B” BEVEL EDGES.

• AVAILABLE ON 707, E6, AND 747 DOORS.

• STANDARD REINFORCEMENTS, LOCKS, OR STRIKES FOR APPLICABLE DOOR SERIES.

• .230” DEEP OFFSET; 4-1/2” ULTIMA HINGE SHIM MUST BE ORDERED SEPARATELY FOR STANDARD

AND HEAVYWEIGHT HINGES.

• 3 AND 4 HINGE LOCATIONS AVAILABLE.

• 12 OR 14 GA. HINGE CHANNEL AVAILABLE.

DOOR A B C D E *HEIGHT

6’8” 9-3/8” 30-1/8” 30-1/8” 9-5/8” —(2032) (238) (765.2) (765.2) (244.5)

7’0” 9-3/8” 32-1/8” 32-1/8” 9-5/8” —(2134) (238) (816) (816) (244.5)

7’2” 9-3/8” 33-1/8” 33-1/8” 9-5/8” —(2184) (238) (841.4) (841.4) (244.5)

8’0” 9-3/8” 25-1/4” 25-1/4” 25-1/4” 10-1/8”(2438) (238) (641.4) (641.4) (641.4) (257.2)

10’0” 9-3/8” 33-1/4” 33-1/4” 33-1/4” 10-1/8”(3048) (238) (845) (845) (845) (257.2)

LOCATION OF HINGE PREPARATIONS

* LOCATION OF 4TH HINGE FOR 8’0” AND 10’0” DOOR

10” (254)

CL

CL

CL

B

A

C

D

Page 42: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

35Standard Locations For 1-3/8” Doors

Door Technical DataSeptember, 2013

L

1/8” (3.2) HEAD CLEARANCE

SIZE A B C D6’8” (2032) 9-5/8” (244.5) 59-7/8” (1520.8) 9-5/8” (244.5) 39-9/16” (1004.9)

7’0” (2133.6) 9-5/8” (244.5) 63-7/8” (1622.4) 9-5/8” (244.5) 39-9/16” (1004.9)

7’2” (2184.4) 9-5/8” (244.5) 65-7/8” (1673.2) 9-5/8” (244.5) 39-9/16” (1004.9)

TWO HINGES

* DIMENSION SHOWN IS FOR LOCKS WITH A COMMON ON LOCK AND STRIKE. (EXAMPLE–CYLINDRICAL LOCK)

CL

HINGE BACKSET 1/4” (6.4)

3/4” (19.1) UNDERCUT STANDARD

A

CL

CL

B

C

CL

* D

HINGE SIZE MAY VARY - LOCATION REMAINS THE SAMECL

FINISHED FLOOR

NOTE: FOR DOORS UNDER 60” TALL WE WILL CENTER THE LOCK FOR ALL MANUFACTURERS LOCATIONS UNLESS NOTED OTHERWISE ON THE ORDER.

Page 43: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

36Standard Locations For 1-3/8” DoorsDoor Technical Data

September, 2013

L

1/8” (3.2) HEAD CLEARANCE

SIZE A B C D6’8” (2032) 9-5/8” (244.5) 29-15/16” (760.4) 9-5/8” (244.5) 39-9/16” (1004.9)

7’0” (2133.6) 9-5/8” (244.5) 31-15/16” (811.2) 9-5/8” (244.5) 39-9/16” (1004.9)

7’2” (2184.4) 9-5/8” (244.5) 32-15/16” (836.6) 9-5/8” (244.5) 39-9/16” (1004.9)

THREE HINGES HINGE BACKSET 1/4” (6.4)

3/4” (19.1) UNDERCUT STANDARD

A

CL

CL

B

C

CL

* D

CL

B

HINGE SIZE MAY VARY - LOCATION REMAINS THE SAMECL

FINISHED FLOOR

* DIMENSION SHOWN IS FOR LOCKS WITH A COMMON ON LOCK AND STRIKE. (EXAMPLE–CYLINDRICAL LOCK)

CL

NOTE: FOR DOORS UNDER 60” TALL WE WILL CENTER THE LOCK FOR ALL MANUFACTURERS LOCATIONS UNLESS NOTED OTHERWISE ON THE ORDER.

Page 44: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

37Standard Locations For 1-3/4” Doors

Door Technical DataSeptember, 2013

L

1/8” (3.2)HEAD CLEARANCE

SIZE A B C D 6’8” (2032) 7-1/8” (181) 30-1/4” (768.4) 11-5/8” (295.3) 39-3/8” (1000.1) 6’10” (2082.8) 7-1/8” (181) 31-1/4” (793.8) 11-5/8” (295.3) 39-3/8” (1000.1) 7’0” (2133.6) 7-1/8” (181) 32-1/4” (819.2) 11-5/8” (295.3) 39-3/8” (1000.1) 7’2” (2184.4) 7-1/8” (181) 33-1/4” (844.6) 11-5/8” (295.3) 39-3/8” (1000.1) 7’4” (2235.2) 7-1/8” (181) 34-1/4” (870) 11-5/8” (295.3) 39-3/8” (1000.1) 7’6” (2286) 7-1/8” (181) 35-1/4” (895.4) 11-5/8” (295.3) 39-3/8” (1000.1) 7’8” (2336.8) 7-1/8” (181) 36-1/4” (920.8) 11-5/8” (295.3) 39-3/8” (1000.1) 7’10” (2387.6) 7-1/8” (181) 37-1/4” (946.2) 11-5/8” (295.3) 39-3/8” (1000.1) 8’0” (2438.4) 7-1/8” (181) 38-1/4” (971.6) 11-5/8” (295.3) 39-3/8” (1000.1) 9’0” (2743.2) 7-1/8” (181) 44-1/4” (1124) 11-5/8” (295.3) 39-3/8” (1000.1) 10’0” (3048) 7-1/8” (181) 50-1/4” (1276.4) 11-5/8” (295.3) 39-3/8” (1000.1)

THREE HINGES

** DIMENSION SHOWN IS FOR LOCKS WITH A COMMON ON LOCK AND STRIKE. (EXAMPLE–CYLINDRICAL LOCK)

CL

HINGE BACKSET 1/4” (6.4)

ACL

B

CL

B

CL

5/8” (15.9) UNDERCUT STANDARD

C

CL

** D

LLLLL

HINGE SIZE MAY VARY - LOCATION REMAINS THE SAMECL

FINISHED FLOOR

NOTE: FOR DOORS UNDER 60” TALL WE WILL CENTER THE LOCK FOR ALL MANUFACTURERS LOCATIONS UNLESS NOTED OTHERWISE ON THE ORDER.

Page 45: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

38Standard Locations For 1-3/4” DoorsDoor Technical Data

September, 2013

L SIZE A B C D

6’8” (2032) 7-1/8” (181) 20-1/8” (511.2) 11-3/4” (298.5) 39-3/8” (1000.1) 6’10” (2082.8) 7-1/8” (181) 20-7/8” (530.2) 11-1/2” (292.1) 39-3/8” (1000.1) 7’0” (2133.6) 7-1/8” (181) 21-1/2” (546.1) 11-5/8” (295.3) 39-3/8” (1000.1) 7’2” (2184.4) 7-1/8” (181) 22-1/8” (562) 11-3/4” (298.5) 39-3/8” (1000.1) 7’4” (2235.2) 7-1/8” (181) 22-7/8” (581) 11-1/2” (292.1) 39-3/8” (1000.1) 7’6” (2286) 7-1/8” (181) 23-1/2” (597) 11-5/8” (295.3) 39-3/8” (1000.1) 7’8” (2336.8) 7-1/8” (181) 24-1/8” (612.8) 11-3/4” (298.5) 39-3/8” (1000.1) 7’10” (2387.6) 7-1/8” (181) 24-7/8” (631.8) 11-1/2” (292.1) 39-3/8” (1000.1) 8’0” (2438.4) 7-1/8” (181) 25-1/2” (647.7) 11-5/8” (295.3) 39-3/8” (1000.1) 9’0” (2743.2) 7-1/8” (181) 29-1/2” (749.3) 11-5/8” (295.3) 39-3/8” (1000.1) 10’0” (3048) 7-1/8” (181) 33-1/2” (850.9) 11-5/8” (295.3) 39-3/8” (1000.1)

* DIMENSION SHOWN IS FOR LOCKS WITH A COMMON ON LOCK AND STRIKE. (EXAMPLE–CYLINDRICAL LOCK)

CL

CL

B

CL

B

CL

CL

B

A

C

CL

* D

HINGE BACKSET 1/4” (6.4)FOUR HINGES

1/8” (3.2)HEAD CLEARANCE

5/8” (15.9) UNDERCUT STANDARD

HINGE SIZE MAY VARY - LOCATION REMAINS THE SAMECL

FINISHED FLOOR

NOTE: FOR DOORS UNDER 60” TALL WE WILL CENTER THE LOCK FOR ALL MANUFACTURERS LOCATIONS UNLESS NOTED OTHERWISE ON THE ORDER.

Page 46: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

39Standard Locations For 1-3/4” Dutch Doors

Door Technical DataNovember, 2004

L SIZE A B C D E F

6’8” (2032) 7-1/8” (181) 24-1/4” (616) 6-5/16” (160.3) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 6’10” (2082.8) 7-1/8” (181) 26-1/4” (666.8) 6-5/16” (160.3) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’0” (2133.6) 7-1/8” (181) 28-1/4” (717.6) 6-5/16” (160.3) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’2” (2184.4) 7-1/8” (181) 30-1/4” (768.4) 6-5/16” (160.3) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’4” (2235.2) 7-1/8” (181) 29-1/4” (743) 9-5/16” (236.5) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’6” (2286) 7-1/8” (181) 31-1/4” (793.8) 9-5/16” (236.5) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’8” (2336.8) 7-1/8” (181) 33-1/4” (844.6) 9-5/16” (236.5) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 7’10” (2387.6) 7-1/8” (181) 35-1/4” (895.4) 9-5/16” (236.5) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3) 8’0” (2438.4) 7-1/8” (181) 37-1/4” (946.2) 9-5/16” (236.5) 7” (177.8) 22-3/4” (577.9) 11-5/8” (295.3)

CL

B

CLC

CL

CL

E

A

F

FOUR HINGES

DCL

34-3/8”(873.1)

HINGE BACKSET 1/4” (6.4)

1/8” (3.2)HEAD CLEARANCE

5/8” (15.9) UNDERCUT STANDARD

3/16”(4.8)

SHELF HEIGHT IS42” (1066.8) STANDARD

DIMENSION SHOWN IS FOR LOCKS WITH A COMMON ON LOCK AND STRIKE. (EXAMPLE–CYLINDRICAL LOCK)

CL

LLLLL

HINGE SIZE MAY VARY - LOCATION REMAINS THE SAMECL

FINISHED FLOOR

CL

49-3/8”(1254.1)*

* PLEASE INDICATE WHEN ADA COMPLIANCE IS REQUIRED. 48” CL IS NOT PRACTICAL WITH SOME DEADLOCKS.

Page 47: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

40747 Dutch DoorDoor Technical Data

July, 2015

L NOTE: 747 FLUSH DUTCH DOORS ARE LABEL LISTED! * FOR LABEL REQUIREMENTS THE TOP LEAF MUST EITHER LATCH INTO THE BOTTOM LEAF OR INTO THE FRAME.

DUTCH DOOR MAY BEMODIFIED AND LABELED ATAN APPROVED SECOND LOCATIONMANUFACTURERS FACILITY.

FRAME STRIKE JAMB

FLAT SURFACE APPLIED ASTRAGAL(OPTIONAL)

NOTCHED FOR E2 STRIKELIP IF REQUIRED

ASTRAGAL MAY BE EITHER WELDED OR SCREW APPLIED

DUTCH HALF SHELF AVAILABLE WITH E2 STRIKE PREP PUNCHED IN SHELF

OPTIONAL: (SHIP LOOSE)E2 STRIKE PREP IN HALF DUTCH DOOR SHELF(DUTCH DOOR SHELF IS LABEL LISTED)(STRIKE IN DOOR SHELF IS NOT ALLOWED ON LABEL DUTCH DOOR)

3’6” (1067) X 7’2” (2184.4) 15 MAX. LABEL SIZES FOR 747, 18 OR 16 GAUGE.** PLEASE INDICATE WHEN ADA COMPLIANCE IS REQUIRED. 48” CL IS NOT PRACTICAL WITH SOME DEADLOCKS.

WELDED IN PLACESTEEL FLUSH CAP(OPTIONAL)

G2 CYLINDRICAL LOCKPREP50” FROM FINISH FLOOR.**

STEEL FLUSH CAP WELDED IN PLACE AND FILLED SMOOTH(OPTIONAL)

E2 STRIKE PREP

G2 LOCK PREP

STANDARD STRIKE PREP

3/16”(4.8)

5/8”(15.9)

UNDERCUT

41-3/8”(1050.9)

7’2” (2184.4) SIZETOP LEAF

43-11/16” (1109.7)

6’8” (2032) SIZETOP LEAF

37-11/16” (957.3)

7’0” (2133.6) SIZETOP LEAF

41-11/16” (1058.9)

APPLIED TO BOTTOM OF TOP LEAFCL

FINISHED FLOOR

Page 48: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

41Dutch Door ShelfDoor Technical Data

April, 2002

LCUSTOMER TO CUT OR GRIND BEVELON END OF SHELF AS REQUIRED TO MATCH DOOR BEVEL AT INSTALLATION

DOOR WIDTH

NOTE: DOORS 3’4” (1016) AND WIDER ADD A THIRD BRACKET LOCATED MIDWAY BETWEEN TWO SHOWN

1-3/4” (44.5)

1” (25.4)

16 GA. (1.4) STANDARD

TOP VIEW

CORNERS WELDED ANDGROUND SMOOTH

16 GA. (1.4) STANDARD 4”(101.6) 1-1/2”

(38.1)

3/4” (19.1)

BOTTOM VIEW

8”(203.2)

10” (254)

Page 49: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

42Dutch Door Double ShelfDoor Technical Data

April, 2002

LCUSTOMER TO CUT OR GRIND BEVELON END OF SHELF AS REQUIRED TO MATCH DOOR BEVEL AT INSTALLATION

NETDOOR WIDTH8” (203.2)

1”(25.4)

16 GA. (1.4) STANDARD

TOP VIEW

16 GA. (1.4) STANDARD

1-1/2”(38.1)

1-3/4”(44.5)

BOTTOM VIEW

4”(101.6)

1-3/4”(445)

17-7/8”(454)

CORNERS WELDED ANDGROUND SMOOTH

10” (254)

8-15/16”(277)

Page 50: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

43Monorail Cutout

Door Technical DataJanuary, 2006

L

FIELD NOTCH FOR MONORAIL

SURFACE MOUNTED 1/4” (6.4) NEOPRENE CLOSING SHEETS

12 GA. (2.6) X 1-1/2” (38.1) ASTRAGAL PLATES

NEOPRENE SHEETS AND ASTRAGAL PLATES ATTACHED TO DOORWITH SCREWS IN A STAGGERED PATTERN.

Page 51: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

44Door TypesDoor Technical Data

June, 2008

L

CURRIES-FSDI-F

E6 PANEL DOOR

FVV

FRV FNVN

FNV4 FNV5

FNV6 2FNV 2FNV 3FNV HGG

HG2G2

HG3G3

HG4G4

HG6G6

HG9 FGFG

FG2 FG3FG3

FG4

FLL

F2LLL

F3L F4L FGL

NOTE: SDI NOMENCLATURE SYMBOLS APPEAR UNDER CURRIES SYMBOLS WHERE APPLICABLE

L L L L

L L L

LLLLLLLL

*

* SEE EMBOSSED DOOR SECTION FOR MORE FACE TYPE DETAILS.

Page 52: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

45Door Types

Door Technical DataSeptember, 2008

L

NOTE: SDI NOMENCLATURE SYMBOLS APPEAR UNDER CURRIES SYMBOLS WHERE APPLICABLE

CURRIES-FVLSDI-VL

FNVLNL

HGLGL

FP F2P FDD

FDFV

FDFNV FDHG FDL FDFVL FDHGL FDFNVL FMS

HGMS FVMS FNVMS

L L L L

L L L L L L L

L LL

2P 2PA 2PAP

Page 53: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

46847 Door Face TypesDoor Technical Data

April, 2002

CURRIES-FSDI-F

FVV

FRV FNVN

FNV4 FNV5

FNV6 2FNV 2FNV 3FNV HGG

HG2G2

HG3G3

HG4G4

HG6G6

HG9 FGFG

FG2 FG3FG3

FG4

FLL

F2LLL

F3L F4L FGL

NOTE: SDI NOMENCLATURE SYMBOLS APPEAR UNDER CURRIES SYMBOLS WHERE APPLICABLE

L

Page 54: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

47847 & 857 Door Face Types

Door Technical DataApril, 2002

NOTE: SDI NOMENCLATURE SYMBOLS APPEAR UNDER CURRIES SYMBOLS WHERE APPLICABLE

CURRIES-FVLSDI-VL

FNVLNL

HGLGL

FP F2P FDD

FDFV

FDFNV FDHG FDL FDFVL FDHGL FDFNVL FMS

HGMS FVMS FNVMS

L

Page 55: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

48Glass Sizes (Visible) and Lite Locations FV, FRBDoor Technical Data

May, 2010

L

FV 10” (254) X 10” (254)FV1 12” (304.8) X 12” (304.8)FRV 12” (304.8) DIA. CUTOUT VISIBLE = 10”FRV1 18” (457.2) DIA. CUTOUT VISIBLE = 16”FRV2 24” (609.6) DIA. CUTOUT VISIBLE = 22”

FLOORLINE

FV FRV

CL

CL

EQUALEQUAL

CL

CL

EQUALEQUAL

65”(1651)

65”(1651)

Type 1 & 2 Window Moulding

Page 56: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

49Glass Sizes (Visible) and Lite Locations FNV

Door Technical DataMay, 2010

L

48” (1219.2)FNV2

6”(152.4)

7-3/4” (196.9)

16” (406.4)FNV

36” (914.4)FNV1

54” (1371.6)FNV3

6”(152.4)

VARIESVARIES

VARIES

VARIES

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS 7’2” (2184.4) AND UNDER

48” (1219.2)FNV2

6”(152.4)

VARIES

16” (406.4)FNV

36” (914.4)FNV1

54” (1371.6)FNV3

6”(152.4)

24-1/4”(616)

30-1/4”(768.4)

42-1/4”(1073.2)

62-1/4”(1581.2)

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS OVER 7’2” (2184.4)

Type 1 & 2 Window Moulding

Page 57: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

50Glass Sizes (Visible) and Lite Locations FNVDoor Technical Data

May, 2010

L6”

(152.4)

7-3/4” (196.9)

33”(838.2)

3”(76.2)

VARIES

FNV4

6”(152.4)

7-3/4” (196.9)

24”(609.6)

4”(101.6)

VARIES

FNV5

6”(152.4)

7-3/4” (196.9)

20”(508)

5”(127)

VARIES

FNV6

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

FINISHED FLOOR

Type 1 & 2 Window Moulding

Page 58: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

51Glass Sizes (Visible) and Lite Locations FNV

Door Technical DataMay, 2010

L6”

(152.4)

7-3/4” (196.9)

24”(609.6)

6”(152.4)

VARIES

FNV7

6”(152.4)

7-3/4” (196.9)

30”(762)

6”(152.4)

VARIES

FNV8

6”(152.4)

7-3/4” (196.9)

25”(635)

4”(101.6)

VARIES

FNV9

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

FINISHED FLOOR

Type 1 & 2 Window Moulding

Page 59: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

52Glass Sizes (Visible) and Lite Locations 2FNVDoor Technical Data

May, 2010

L

48” (1219.2)2FNV2

6”(152.4)

7-3/4” (196.9)

16” (406.4)2FNV

36” (914.4)2FNV1

54” (1371.6)2FNV3

6”(152.4)VARIES

VARIES

VARIES

VARIES

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS 7’2” (2184.4) AND UNDER

6”(152.4)

6”(152.4)

48” (1219.2)2FNV2

6”(152.4)

VARIES

16” (406.4)2FNV

36” (914.4)2FNV1

54” (1371.6)2FNV3

6”(152.4)

24-1/4”(616)

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS OVER 7’2” (2184.4)

6”(152.4)

6”(152.4)

30-1/4”(768.4)

42-1/4”(1073.2)

62-1/4”(1581.2)

Type 1 & 2 Window Moulding

Page 60: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

53Glass Sizes (Visible) and Lite Locations 2FNV

Door Technical DataMay, 2010

L6”

(152.4)

7-3/4” (196.9)

33”(838.2)

3”(76.2)

VARIES

* 2FNV4

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

6”(152.4)

3”(76.2)

6”(152.4)

7-3/4” (196.9)

24”(609.6)

4”(101.6)

VARIES

6”(152.4)

4”(101.6)

* 2FNV56”

(152.4)

7-3/4” (196.9)

20”(508)

5”(127)

VARIES

6”(152.4)

* 2FNV6

5”(127)

FINISHED FLOOR

* MINIMUM 6” (152.4) STILES TO BE LABEL APPROVED

Type 1 & 2 Window Moulding

Page 61: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

54Glass Sizes (Visible) and Lite Locations 2FNVDoor Technical Data

May, 2010

L6”

(152.4)

VARIES

33”(838.2)

3”(76.2)

45-1/4”(1149.4)

* 2FNV4

STANDARD LOCATIONS FORDOORS OVER 7’2”

FINISHED FLOOR

6”(152.4)

3”(76.2)

6”(152.4)

VARIES

24”(609.6)

4”(101.6)

54-1/4”(1378)

6”(152.4)

4”(101.6)

* 2FNV56”

(152.4)

VARIES

20”(508)

5”(127)

58-1/4”(1479.6)

6”(152.4)

* 2FNV6

5”(127)

FINISHED FLOOR

* MINIMUM 6” (152.4) STILES TO BE LABEL APPROVED

Type 1 & 2 Window Moulding

Page 62: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

55Glass Sizes (Visible) and Lite Locations HG, HG2

Door Technical DataMay, 2010

L6”

(152.4)6”

(152.4)

7-3/4” (169.9)

VARIES

HG

6”(152.4)

6”(152.4)

7-3/4” (169.9)

VARIES (EQUAL)

HG2

L L

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-13/16” (300)

2’4” (711.2) 15-13/16” (401.6)

2’6” (762) 17-13/16” (452.4) 6’8” (2032) 28” (711.2)

2’8” (812.8) 19-13/16” (503.2)

2’10” (863.6) 21-13/16” (554)

3’0” (914.4) 23-13/16” (604.8) 7’0” (2133.6) 32” (812.8)

3’4” (1016) 27-13/16” (706.4)

3’6” (1066.8) 29-13/16” (757.2)

3’8” (1117.6) 31-13/16” (808) 7’2” (2184.4) 34” (863.6)

3’10” (1168.4) 33-13/16” (858.8)

4’0” (1219.2) 35-13/16” (909.6)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-13/16” (330)

2’4” (711.2) 15-13/16” (401.6)

2’6” (762) 17-13/16” (452.4) 6’8” (2032) 13-9/16” (344.5)

2’8” (812.8) 19-13/16” (503.2)

2’10” (863.6) 21-13/16” (554)

3’0” (914.4) 23-13/16” (604.8) 7’0” (2133.6) 15-9/16” (395.3)

3’4” (1016) 27-13/16” (706.4)

3’6” (1066.8) 29-13/16” (757.2)

3’8” (1117.6) 31-13/16” (808) 7’2” (2184.4) 16-9/16” (420.7)

3’10” (1168.4) 33-13/16” (858.8)

4’0” (1219.2) 35-13/16” (909.6)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

44-1/8” (1120.8)44-1/8” (1120.8)

SEE MUNTIN BAR

FINISHED FLOOR

Type 1 & 2 Window Moulding

Page 63: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

56Glass Sizes (Visible) and Lite Locations HG2, HG4Door Technical Data

May, 2010

L6”

(152.4)6”

(152.4)

7-3/4” (169.9)

VARIES (EQUAL)

HG3

6”(152.4)

6”(152.4)

7-3/4” (169.9)

VARIES (EQUAL)

HG4

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-13/16” (300)

2’4” (711.2) 15-13/16” (401.6)

2’6” (762) 17-13/16” (452.4) 6’8” (2032) 8-3/4” (222.3)

2’8” (812.8) 19-13/16” (503.2)

2’10” (863.6) 21-13/16” (554)

3’0” (914.4) 23-13/16” (604.8) 7’0” (2133.6) 10-5/64” (256)

3’4” (1016) 27-13/16” (706.4)

3’6” (1066.8) 29-13/16” (757.2)

3’8” (1117.6) 31-13/16” (808) 7’2” (2184.4) 10-3/4” (273)

3’10” (1168.4) 33-13/16” (858.8)

4’0” (1219.2) 35-13/16” (909.6)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 5-15/32” (138.9)

2’4” (711.2) 7-15/32” (189.7)

2’6” (762) 8-15/32” (215.1) 6’8” (2032) 13-9/16” (344.5)

2’8” (812.8) 9-15/32” (240.5)

2’10” (863.6) 10-15/32” (265.9)

3’0” (914.4) 11-15/32” (291.3) 7’0” (2133.6) 15-9/16” (395.3)

3’4” (1016) 13-15/32” (342.1)

3’6” (1066.8) 14-15/32” (367.5)

3’8” (1117.6) 15-15/32” (392.9) 7’2” (2184.4) 16-9/16” (420.7)

3’10” (1168.4) 16-15/32” (418.3)

4’0” (1219.2) 17-15/32” (443.7)

VARIES (EQUAL)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

SEE MUNTIN BAR

FINISHED FLOOR

44-1/8” (1120.8) 44-1/8” (1120.8)

Type 1 & 2 Window Moulding

Page 64: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

57Glass Sizes (Visible) and Lite Locations HG6, HG9

Door Technical DataMay, 2010

L6”

(152.4)6”

(152.4)

7-3/4” (169.9)

VARIES (EQUAL)

HG6

6”(152.4)

6”(152.4)

7-3/4” (169.9)

VARIES (EQUAL)

HG9

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 3-5/16” (84.1)

2’4” (711.2) 4-5/8” (117.5)

2’6” (762) 5-5/16” (134.9) 6’8” (2032) 8-3/4” (222.3)

2’8” (812.8) 6” (152.4)

2’10” (863.6) 6-5/8” (168.3)

3’0” (914.4) 7-5/16” (185.7) 7’0” (2133.6) 10-5/64” (256)

3’4” (1016) 8-5/8” (219.1)

3’6” (1066.8) 9-5/16” (236.5)

3’8” (1117.6) 10” (254) 7’2” (2184.4) 10-3/4” (273)

3’10” (1168.4) 10-5/8” (269.9)

4’0” (1219.2) 11-5/16” (287.3)

VARIES (EQUAL)VARIES (EQUAL)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 5-15/32” (138.9)

2’4” (711.2) 7-15/32” (189.7)

2’6” (762) 8-15/32” (215.1) 6’8” (2032) 8-3/4” (222.3)

2’8” (812.8) 9-15/32” (240.5)

2’10” (863.6) 10-15/32” (265.9)

3’0” (914.4) 11-15/32” (291.3) 7’0” (2133.6) 10-5/64” (256)

3’4” (1016) 13-15/32” (342.1)

3’6” (1066.8) 14-15/32” (367.5)

3’8” (1117.6) 15-15/32” (392.9) 7’2” (2184.4) 10-3/4” (273)

3’10” (1168.4) 16-15/32” (418.3)

4’0” (1219.2) 17-15/32” (443.7)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

FINISHED FLOOR

SEE MUNTIN BAR

44-1/8” (1120.8) 44-1/8” (1120.8)

Type 1 & 2 Window Moulding

Page 65: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

58Glass Sizes (Visible) and Lite Locations FG, FGLDoor Technical Data

May, 2010

L6”

(152.4)6”

(152.4)

7-3/4” (169.9)

VARIES

FG

EQUAL EQUAL

7-7/8” (200)

VARIES

FGL

12”(304.8)

12”(304.8)FINISHED FLOOR LL

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-13/16” (300)

2’4” (711.2) 15-13/16” (401.6)

2’6” (762) 17-13/16” (452.4) 6’8” (2032) 60-1/8” (1527.2)

2’8” (812.8) 19-13/16” (503.2)

2’10” (863.6) 21-13/16” (554)

3’0” (914.4) 23-13/16” (604.8) 7’0” (2133.6) 64-1/8” (1628.8)

3’4” (1016) 27-13/16” (706.4)

3’6” (1066.8) 29-13/16” (757.2)

3’8” (1117.6) 31-13/16” (808) 7’2” (2184.4) 66-1/8” (1679.6)

3’10” (1168.4) 33-13/16” (858.8)

4’0” (1219.2) 35-13/16” (909.6)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 12” (304.8)

2’4” (711.2) 16” (406.4)

2’6” (762) 18” (457.2) 6’8” (2032) 60” (1524)

2’8” (812.8) 20” (508)

2’10” (863.6) 22” (558.8)

3’0” (914.4) 24” (609.6) 7’0” (2133.6) 64” (1625.6)

3’4” (1016) 28” (711.6)

3’6” (1066.8) 30” (762)

3’8” (1117.6) 32” (812.8) 7’2” (2184.4) 66” (1676.4)

3’10” (1168.4) 34” (863.6)

4’0” (1219.2) 36” (914.4)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

Type 1 & 2 Window Moulding

Page 66: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

59Glass Sizes (Visible) and Lite Locations FG2, FG3, FG4

Door Technical DataMay, 2010

L6”

(152.4)

7-3/4” (169.9)

FG2

6”(152.4)

VARIES (EQUAL)

6” (152.4)

VARIES (EQUAL)

12” (304.8)

6”(152.4)

7-3/4” (169.9)

FG3

6”(152.4)

VARIES (EQUAL)

6” (152.4)

VARIES (EQUAL)

12” (304.8)

VARIES (EQUAL)

6” (152.4)

6”(152.4)

7-3/4” (169.9)

6”(152.4)

VARIES (EQUAL)

6” (152.4)

12” (304.8)

6” (152.4)

VARIES (EQUAL)

VARIES (EQUAL)

VARIES (EQUAL)

6” (152.4)

FG4

FINISHED FLOOR

DOOR VISIBLE DOOR VISIBLE DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT HEIGHT HEIGHT HEIGHT HEIGHT

2’0” (609.6) 11-13/16” (330)

2’4” (711.2) 15-13/16” (401.6)

2’6” (762) 17-13/16” (452.4) 6’8” (2032) 27-1/16” 6’8” (2032) 16-1/16” 6’8” (2032) 10-9/16” (687.4) (408) (268.3)

2’8” (812.8) 19-13/16” (503.2)

2’10” (863.6) 21-13/16” (554)

3’0” (914.4) 23-13/16” (604.8) 7’0” (2133.6) 29-1/16” 7’0” (2133.6) 17-3/8” 7’0” (2133.6) 11-9/16” (738.2) (441.3) (293.7)

3’4” (1016) 27-13/16” (706.4)

3’6” (1066.8) 29-13/16” (757.2)

3’8” (1117.6) 31-13/16” (808) 7’2” (2184.4) 30-1/16” 7’2” (2184.4) 18-1/16” 7’2” (2184.4) 12-1/16” (763.6) (458.8) (306.4)

3’10” (1168.4) 33-13/16” (858.8)

4’0” (1219.2) 35-13/16” (909.6)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

FG2 FG3 FG4

* * *

* NOTE: A MINIMUM 6” STILE AND 6” RAIL IS REQUIRED FOR FIRE LABEL LISTED DOOR)

Type 1 & 2 Window Moulding

Page 67: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

60Face Type Locations FVL, FNVLDoor Technical Data

May, 2010

12”(304.8)

FINISHED FLOOR

EQUAL EQUAL

VARIES

VARIES

12”(304.8)

VARIES

6”(152.4)

7-3/4” (196.9)

VARIES

VARIES

12”(304.8)

12”(304.8)

FVL FV = FULL VISION STANDARDS L = LOUVER STANDARDS

FNVL FNV = FULL NARROW VISION STANDARDS L = LOUVER STANDARDS

EXAMPLE: 12” X 12” (305 X 305) FULL VISION LITE

18” X 12” (457 X 305) LOUVER

EXAMPLE:6” X 36” (152 X 914) NARROW VISION LITE

18” X 12” (457 X 305) LOUVER

FV1L2 FNV1L2

L

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

CL

65”(1651)

Type 1 & 2 Window Moulding

Page 68: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

61Face Type Locations HGL

Door Technical DataMay, 2010

6”(152.4)

6”(152.4)

7-3/4” (169.9)

VARIES

12”(304.8)

VARIES12”(304.8)

L

HGL HG = HALF GLASS STANDARDS L = LOUVER STANDARDS

FINISHED FLOOR

EXAMPLE: WINDOW PANE-HALF GLASS

18” X 12” (457 X 305) LOUVER

HG L2

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

Type 1 & 2 Window Moulding

Page 69: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

62Glass Sizes (Visible) and Lite Locations F2NV, 3FNVDoor Technical Data

May, 2010

L6”

(152.4)

FINISHED FLOOR

7-3/4” (196.9)

16” (406.4)

16” (406.4)

6” (152.4)

6”(152.4)

F2NV

6”(152.4)

7-3/4” (196.9)

16” (406.4)

3FNV

EQUAL

6”(152.4)

6”(152.4)

6”(152.4)

6”(152.4)

6”(152.4)

42”(1066.8)

FD

EQUAL

VARIES

FDFV

EQUAL

VARIES

42”(1066.8)

L L

DOOR WIDTH FOR 3FNV MUST BE AT LEAST 3’6” (1066.8) WIDE!

Face Type Locations FD, FDFV

FDFV 10” (254) X 10” (254)FDFV1 12” (304.8) X 12” (304.8)

* NOTE: MINIMUM 6” STILES TO BE FIRE LABEL LISTED.

CL

65”(1651)

Type 1 & 2 Window Moulding

Page 70: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

63Face Type Locations FDFNV, FDHG

Door Technical DataMay, 2010

L

6”(152.4)

7-3/4” (169.9)

VARIES

FINISHED FLOOR

VARIES

42”(1066.8)

6”(152.4)

7-3/4” (169.9)

VARIES

42”(1066.8)

6”(152.4)

5-15/16” (150.8)

FDFNV FD = FLUSH DUTCH FNV = FULL NARROW VISION STANDARDS

FDHG FD = FLUSH DUTCH HG = HALF GLASS STANDARDS

EXAMPLE: FLUSH DUTCH

6” X 36” (152 X 914) NARROW VISION LITE

EXAMPLE:FLUSH DUTCH

(3) WINDOW PANE-HALF GLASS

FDFNV1 FDHG

Type 1 & 2 Window Moulding

Page 71: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

64Face Type Locations FDL, FDFVLDoor Technical Data

May, 2010

L

FINISHED FLOOR

42”(1066.8)

VARIES

42”(1066.8)

FDL FD = FLUSH DUTCH L = LOUVER STANDARDS

FDFVL FD = FLUSH DUTCH FV = FULL VISION STANDARDS L = LOUVER STANDARDS

EXAMPLE: FLUSH DUTCH

20” X 12” (508 X 305) LOUVER

EXAMPLE:FLUSH DUTCH

12” X 12” (305 X 305) FULL VISION LITE20” X 12” (508 X 305) LOUVER

FDL3

12”(304.8)

12”(304.8)

EQUAL EQUAL

VARIES

12”(304.8)

12”(304.8)

VARIES

FDFV1L3

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

CL

65”(1651)

Type 1 & 2 Window Moulding

Page 72: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

65Face Type Locations FDHGL, FDFNVL

Door Technical DataMay, 2010

L

FINISHED FLOOR

FDHGL FD = FLUSH DUTCH HG = HALF GLASS STANDARDS L = LOUVER STANDARDS

FDFNVL FD = FLUSH DUTCH FNV = FULL NARROW VISION STANDARDS L = LOUVER STANDARDS

EXAMPLE: FLUSH DUTCH

(3) WINDOW PANE-HALF GLASS18” X 12” (457 X 305) LOUVER

EXAMPLE:FLUSH DUTCH

6” X 36” (152 X 914) NARROW VISION LITE18” X 12” (457 X 305) LOUVER

FDHG3L2

6”(152.4)

7-3/4” (169.9)

VARIES

42”(1066.8)

6”(152.4)

5-15/16” (150.8)

12”(304.8)

12”(304.8)

VARIES

6”(152.4)

7-3/4” (169.9)

VARIES

42”(1066.8) 12”

(304.8)

12”(304.8)

VARIES

VARIES

FDFNV1L2

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

Type 1 & 2 Window Moulding

Page 73: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

66Door Vision Lite Frame 1-3/8” DoorDoor Technical Data

May, 2010

L

18 GA. (1.2) GALV. STEELVISION LITE FRAME

1/4” (6.3) GLASS3/8” (9.5) POCKET ONLY

VISIBLE GLASSAREA

VISIBLE GLASSAREA

4-7/8” (123.8) MINIMUMBETWEEN VISIBLE GLASS AREAS.

(INCLUDES MOULDING)6” MIN. VISIBLE FOR FIRE LABEL

NOTE: ORDER GLASS SIZE 1” LARGER THANVISIBLE GLASS DIMENSION CORNER DETAIL WITH

CORNER CLIP WELDED IN

20 GA. (.91)WINDOWSUB CHANNELUSED ONDOORS ONLY

1-3/8” DOOR(34.9)

9/16” (14.3)APPROX.

POP RIVET

REMOVABLEINTERIORFRAME

#6-20 OVALHEAD SCREW

GLASS

EXTERIOR FRAME

L

20 GA. (.91) MOULDING RETAINING CLIP

5/8”(15.9)

5/8”(15.9)

11/16”(17.5)1-5/16”

(33.3)

3/8”(9.5)

1-5/16”(33.6)

Type 1 & 2 Window Moulding

Page 74: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

67Window Kit Cutout on Door

Door Technical DataMay, 2010

L

1-5/16”(33.3)

DOOR

7/8”

DOOR CUT-OUT1-3/4” LARGER THAN VISIBLE

3/32”

1-5/16”7/16”

1/2”(GLASS SIZE 1” LARGER THAN

VISIBLE)

WINDOW KIT

GLASS SIZE

CUT-OUT

KIT BEYOND CUT-OUT

VISIBLEGLASS

1/2”(12.7)

7/8”(22.2)

7/16”(11)

Type 1 & 2 Window Moulding

Page 75: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

68Louver Sizes and Locations FL, F2L, F3L, F4LDoor Technical Data

April, 2002

L

EQUAL EQUAL

VARIES

12”(304.8)

12”(304.8) FINISHED FLOOR

L

EQUAL EQUAL

VARIES

12”(304.8)

12”(304.8)

12”(304.8)

7-7/8” (200)

FL F2L

FINISHED FLOOR

F3L F4L

L

EQUAL EQUAL

VARIES

12”(304.8)

12”(304.8)

12”(304.8)

7-7/8” (200)

12”(304.8)

EQUAL

EQUAL

L

EQUAL EQUAL

VARIES

12”(304.8)

12”(304.8)

12”(304.8)

7-7/8” (200)

12”(304.8)

EQUAL

EQUAL

12”(304.8)

EQUAL

FL F2L F3L F4L 12” (304.8) X 12” (304.8)FL2 F2L2 F3L2 F4L2 18” (457.2) X 12” (304.8)FL3 F2L3 F3L3 F4L3 20” (508) X 12” (304.8)FL4 F2L4 F3L4 F4L4 24” (609.6) X 12” (304.8)

Page 76: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

69Louver Cutout on Door

Door Technical DataApril, 2002

L

5/8”(15.9)

Louver Cutout Reinforcing (Optional)

L

LOUVERS ARE SIZED TO FITSTANDARD OPENING DIMENSIONEXAMPLE: A 12” (304.8) X 12” (304.8) LOUVERREQUIRES A 12” (304.8) X 12” (304.8) CUTOUT IN DOOR

MUST BE LABELAPPROVED LOUVER

CUTOUTSIZE

LOUVERSIZE

12”(304.8)

12”(304.8)

12”(304.8)

12”(304.8)

NOTE: LOUVER CUTOUT REINFORCING IS NOT PROVIDED AS STANDARD BUT MAY BE FURNISHED ON REQUEST.

REINFORCING IS REQUIRED ON FIRE LABELED DOORS AND IS PROVIDED AS STANDARD.

1-1/2”(38.1)

20 GA. (.91) CHANNEL

CUTOUT SIZE = LOUVER SIZE

Page 77: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

70Face Type Locations FP, F2PDoor Technical Data

April, 2002

L

Transfer Core Type Louver Moulding

EQUAL EQUAL

CL

CL

60”(1524)

1/2” DIA.(12.7)

EQUAL EQUAL

CL

CL

45”(1143)

1/2” DIA.(14.3)

CL

60”(1524)

FLOORLINE

FP F2PFP F2P 1/2” (12.7) DIA.FP1 F2P1 9/16” (14.3) DIA.

1/2” (12.7) TRANSFER CORE TYPE LOUVER BY OTHERS

CUSTOM MOULDING

9/16”(14.3)

1/2”(12.7)

1/2”(50.8)

5/8”(15.9)

L

TYPE 3

Page 78: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

71Face Type Locations FMS, HGMS

Door Technical DataMay, 2010

L

FINISHED FLOOR

EQUAL EQUAL

PER TEMPLATE

30”(762)

6”(152.4)

6”(152.4)

VARIES

EQUAL EQUAL

PER TEMPLATE

30”(762)

FMS FMS = FLUSH MAIL SLOT

HGMS HG = HALF GLASS STANDARDS MS = MAIL SLOT

EXAMPLE: (3) WINDOW PANE-HALF GLASS

MAIL SLOT

HG3MS

7-3/4” (169.9)

Type 1 & 2 Window Moulding

Page 79: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

72Face Type Locations FVMS, FNVMSDoor Technical Data

May, 2010

VARIES

FINISHED FLOOR

EQUAL

EQUAL

PER TEMPLATE

30”(762)

6”(152.4)

VARIES

EQUAL EQUAL

PER TEMPLATE

30”(762)

FVMS FV = FULL VISION STANDARDS MS = MAIL SLOT

FNVMS FNV = FULL NARROW VISION STANDARDS MS = MAIL SLOT

EXAMPLE: 6” X 36” (152 X 914) NARROW VISION LITE

MAIL SLOT

FNV1MS

L

EQUAL

VARIES

VARIES

EQUAL

7-3/4”(196.9)

FVMS 10” (254) X 10” (254)FV1MS 12” (304.8) X 12” (304.8)

CL

65”(1651)

Type 1 & 2 Window Moulding

Page 80: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

73Muntin Bar - Muntin Bar Joints

Door Technical DataNovember, 2012

L

VERTICAL MUNTIN FOR1/4” (6.4) GLASS ONLY!

5/16” (7.9) INSIDE

11/32”(8.7)

HORIZONTAL MUNTIN FOR1/4” (6.4) GLASS ONLY!

NOTCH VERTICAL MUNTIN 3/16” (4.8) TO FIT INSIDE HORIZONTAL MUNTIN

MULTIPLE GLASS SIZES MAY VARYSLIGHTLY DUE TO MUNTINPOCKET DEPTH

3/16”(4.8)

9/16” (14.3)OUTSIDE

7/32”(5.6)

29/32”(23)

3/8”(9.5)

3/8”(9.5)

AVAILABLE FOR TYPE 1, 3, 9 AND 11 WITH 3/8” POCKET ONLY.AVAILABLE WITH CURRISTAIN DOORS. MUNTIN BAR IS NOT STAINED.

MUNTIN BAR PART NUMBER: CD002402

VISION LITE FRAME

HORIZONTAL MUNTIN

NOTCH HORIZONTAL MUNTIN 3/8” (9.5) TO FIT INSIDE WINDOW KIT FRAME

4-7/8” (123.8) MINIMUMBETWEEN VISIBLEGLASS AREAS.(INCLUDES MOULDING)

VISIBLE GLASS

Page 81: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

74Cut Away View FG MouldingDoor Technical Data

April, 2002

L

HINGE OR LOCK CHANNEL

20 GAUGE (.91) STANDARDCHANNEL REINFORCING

18 GA. (1.2) GALV. STEELGLASS MOULDING

#6 OVALHEAD SCREW

INVERTED TOP ORBOTTOM CHANNEL

OUTSIDE SKIN

STANDARD WINDOW MOULDINGTYPE 1

Page 82: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

75Door Vision Lite Kit (Old Style)

Door Technical DataFebruary, 2008

LTYPE 1 - POCKET SIZE: 3/8” (9.5)TYPE 2 - POCKET SIZE: 5/8” (15.9) 7/8” (22.3) 1-1/8” (28.6)

CORNER DETAIL WITH CORNER CLIP WELDED IN

13/16”(20.6)

*

13/16”(20.6)

*11/16”(17.5)

1-5/16”(33.3)

1-5/16”(33.3)

20 GA. (.91) MOULDING RETAINING CLIP

*VARIES WITH POCKET

EXTERIOR FRAME

GLASS

9/16” (14.3)APPROX.

#6 SCREW

REMOVABLE INTERIOR FRAME

POP RIVET

20 GA. (.91)U.L. SUB-CHANNEL

CLIP

1-3/4” (44.5)

18 GA. (1.2) GALVANIZED STEEL VISION LITE FRAME

STEEL VISION LITE FRAME KITS AND STICK LENGTH PARTS ARE AVAILABLE FOR USE ON 847 SERIES DOORS.

VISIBLE GLASS AREA

VISIBLE GLASS AREA

4-7/8” (124) MINIMUM BETWEEN VISIBLE GLASS AREAS. (INCLUDES MOULDING)

NOTE: ON FIRE LABEL DOORS USE A 6” (152.4) MINIMUM STILE BETWEEN VISIBLE GLASS AREAS AND BETWEEN VISIBLE GLASS AND EDGES OF DOOR.

TYPES 1 & 2

NOTE: PLEASE NOTE WHEN KITS SHOULD BE USED ON 14 GAUGE DOORS.

SEE PAGE 155 FOR CURRIES STANDARD WINDOW KIT INFORMATION.

Page 83: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

76Wide Pocket Glass MouldingDoor Technical Data

June, 2017

7/8”(22.2)

L

Rabbeted Door and Panel

L

U.L. APPROVED

PANEL

DOOR

1/8” (3.2)

5/8” (15.9) STANDARDRABBET DEPTH

1/16” (1.6)

NOMINALPANEL HEIGHT

NOMINALPANEL HEIGHT

“A” SKIN

“B” SKIN

TYPE 2 (old style kits)

1-1/8” POCKET 7/8” POCKET 5/8” POCKET

1-3/4” (44.5)DOOR

1-3/4” (44.5)DOOR

1-3/4” (44.5)DOOR

1-5/16” (33.3)

11/16” (17.5)

7/16” (11.1)

7/16” (11.1) 1-1/8”

(28.6)

1-5/16” (33.3)

11/16” (17.5)

9/16” (14.3)

9/16” (14.3) 5/8”

(15.9)

1-5/16” (33.3)

11/16” (17.5)

9/16” (14.3)

13/16” (20.6)

1-3/4” (44.5) ONLY

SEE PAGE 155 FOR CURRIES STANDARD WINDOW KIT INFORMATION.

Page 84: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

77Concealed Glass Moulding - Type 3

Door Technical DataMay, 2013

L

THIS SURFACE PUNCHED AND COUNTERSUNK, ON CEN-TER, FOR #6-20 OVAL HEAD SCREW.

GLASS THICKNESS PLUS.125 = POCKETGLASS SIZE IS 1” LARGER THAN VISIBLECUTOUT SIZE IS 1-1/4” LARGER THAN VISIBLE

REMOVABLE MOULDING

NOTE:REMOVABLE MOULDING IS ALWAYS ON THE INTERIOR SIDE UNLESS NOTED DIFFERENTLY ON THE ORDER.

DOOR SKINMOULDING WELDED

3/8” (9.5)POCKET

5/8” (15.9)

7/8” (22.2)

3/8”, 1/2” AND 5/8” POCKETS ONLY1-3/4” DOORS ONLY

*

*

*

**

3-1/8” (79.3) MINIMUM STILE AND RAIL AVAILABLE WITH TYPE 3 MOULDING. “NO FIRE LISTING,” LIM-ITED HARDWARE.

*

1-1/2” (38.1)

Page 85: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

78Special Concealed Moulding - “Z” TypeDoor Technical Data

August, 2013

LVARIES3/8” (9.5) MIN.1-1/8” (28.6) MAX.

18 GA. (1.2) REMOVABLE MOULDING

TYPE 4

THIS SURFACE PUNCHED ANDCOUNTERSUNK FOR #6–20 OVAL HEAD SCREW.6” ON CENTER FOR

NOTE: REMOVABLE MOULDING IS TO BE ON INTE-RIOR SIDE OF DOOR UNLESS NOTED DIFFERENTLY ON THE ORDER.

16 GA. (1.4)“Z” CHANNEL REINFORCEMENT

VARIES

5/8” (15.9)

5/8” (15.9)

5/8” (15.9)

DOOR SKIN1-3/4” (44.5) DOOR ONLY

L

2-7/8” (73) MINIMUM RAIL TO VISIBLE BETWEEN KITS

GLASS THICKNESS PLUS.125 = POCKETGLASS SIZE IS 1” LARGER THAN VISIBLEREMOVABLE SIDE CUTOUT SIZE IS 1-1/4” LARGER THAN VISIBLE

Page 86: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

79857 Standard 18 Ga. Concealed Moulding

Door Technical DataNovember, 2016

L3/8” (9.5), 1/2” (12.7), OR 5/8” (15.8) POCKETS

REMOVABLE STOP (18 GA.)5/8” (15.9) X 5/8” (15.9)

SPOT WELD

#6 SCREW9/16”(14.3)MIN.

5/8” (15.9)

SPOT WELD

WELD

18 GA.

TYPE 3 TYPE 3CONCEALED MOULDING

18 GA. (1.2)

3/8” (9.5) TO1-1/8” (28.6) POCKETSIN 1/8” (3.2) INCREMENTS

#6 SCREW

REMOVABLE STOP (18 GA.)5/8” (15.9) X 5/8” (15.9)

SPOT WELD

SPOT WELD

5/8” (15.9)

16 GA.

TYPE 4 TYPE 4CONCEALED MOULDING

WIDE POCKET18 GA. (1.2)

2” (50.8)

2” (50.8)

2” DOOR

NOTE: REMOVABLE MOULDING IS TO BE ON INTERIOR SIDE OF DOOR UNLESS NOTED DIFFERENTLY ON THE ORDER

Page 87: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

80E1 ANSI Strike Preparation in Inactive LeafDoor Technical Data

April, 2011

L

4-7/8”(123.8)

FINISHED FLOOR

CL

1-1/4”(31.8)

1/8” (3.2)LIP DEPTH

CONTINUOUS LOCK CHANNEL

40” (1016) TO STANDARDCL

NOTES1. MORTISE AND TAP PER ANSI/BHMA A156.1152. REINFORCED IN ACCORDANCE WITH ANSI A250.6

3-3/8”(85.7)

TABS FORMED INTEGRAL WITH LOCK CHANNEL

PIERCE AND EXTRUDEMOUNTING HOLES

Page 88: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

81E2 Strike Preparation in Inactive Leaf

Door Technical DataApril, 2002

L

1-1/2”(38.1)

FINISHED FLOOR

CL

12 GA. (2.6)REINFORCEMENT

1-1/4”(31.8)

1/8” (3.2)LIP DEPTH

CONTINUOUS LOCK CHANNEL

40” (1016) TO STANDARDCL

2-3/4”(69.9)

Page 89: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

82E3 ANSI Deadlock Strike Preparation in Inactive LeafDoor Technical Data

April, 2002

L

3-1/2”(88.9)

FINISHED FLOOR

CL

12 GA. (2.6)REINFORCEMENT

1-1/8”(28.6)

CONTINUOUS LOCK CHANNEL

48” (1219) TO STANDARDCL

SIZE AND TAP PER ANSI A115.5 FOR MORTISE DEADLOCKS

Page 90: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

83E4 Strike Preparation in Inactive Leaf

Door Technical DataApril, 2002

L

2-3/4”(69.9)

FINISHED FLOOR

CL

12 GA. (2.6)TABS

1-1/8”(28.6)

CONTINUOUS LOCK CHANNEL

48” (1219) TO STANDARDCL

Page 91: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

84Open Back Strike (SOB)Door Technical Data

April, 2002

L

PER TEMPLATE

FINISHED FLOOR

CL

PER TEMPLATE

CONTINUOUS LOCK CHANNEL

SIZE AND TAP PER TEMPLATE

PER TEMPLATE

PER TEMPLATE

PER TEMPLATE

12 GA. (2.6)TABS

PER TEMPLATETO ALIGN WITH

LOCK

Page 92: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

85857 Security Door Open Back Strike (SOB)

Door Technical DataApril, 2002

ADDITIONAL REINFORCEMENT INSTALLED IF LIP DEPTH IS LONGER THAN LOCK CHANNEL LEG.

PER TEMPLATE

PER TEMPLATE

PER TEMPLATE

PER TEMPLATECL

FINISHED FLOOR

PER TEMPLATETO ALIGN WITH LOCK

12 GA. (2.6) REIN-FORCE AND TAP PER TEMPLATE

PER TEMPLATE

2” (50.8)

L2” DOOR

Page 93: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

86Door Electric Strike (E9)Door Technical Data

April, 2002

L

PER TEMPLATECL

12 GA. (2.6)TABS

ELECTRICRACEWAY

CONTINUOUS LOCK CHANNELFOAM

HINGE CHANNEL

PER TEMPLATE

PER TEMPLATE

FINISHED FLOOR

PER TEMPLATETO ALIGN WITH

LOCK

SIZE AND TAP PER TEMPLATE

Page 94: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

87Steel Stiffened Door Electric Strike (E9)

Door Technical DataApril, 2002

L

PER TEMPLATECL

12 GA. (2.6)TABS

ELECTRICRACEWAY

CONTINUOUS LOCK CHANNELFIBERGLASS INSULATION

HINGE CHANNEL

PER TEMPLATE

PER TEMPLATE

FINISHED FLOOR

PER TEMPLATETO ALIGN WITH

LOCK

SIZE AND TAP PER TEMPLATE

Page 95: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

88857 E9 Security Door Electric StrikeDoor Technical Data

April, 2002

ADDITIONAL REINFORCEMENT INSTALLED IF LIP DEPTH IS LONGER THAN LOCK CHANNEL LEG.

2” (50.8)

PER TEMPLATE

PER TEMPLATE

PER TEMPLATE

PER TEMPLATECL

FLOOR

PER TEMPLATETO ALIGN WITH LOCK

12 GA. (2.6) REIN-FORCE AND TAP PER TEMPLATE

L 2” DOOR

Page 96: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

89Flat Surface Astragal Locations

Door Technical DataOctober, 2010

L

CURRIES STANDARD PRACTICE IS TOSUPPLY ASTRAGAL 5/8” (15.9) SHORT OF DOOR HEIGHT TO CLEAR FRAME STOP AT HEAD ON INAC-TIVE DOOR ONLY!

HIGHSIDEAPPL.

1 2

DOORHEIGHTACTIVE

DOORHEIGHTLESS

5/8” (15.9)INACTIVE

(*)

AS REQ’D

6” (152) TYP.

STANDARD SCREW PLACEMENT USING#6 OVAL HEAD SCREWS (ALSOAVAILABLE WELDED) “MIN. REQ’D FOR U.L. LISTING”

(*) SPECIAL STOP HEIGHTS CAN VARY LENGTHS

ACTIVE INACTIVE

INACTIVELEAF

INACTIVELEAF

INACTIVELEAF

BEVELED EDGE

BEVELED EDGE

SQUARE EDGE

7/8” (22.2) 7/8” (22.2)

7/8” (22.2)

SINGLE ASTRAGAL ON LOW SIDE OF INACTIVE LEAF STANDARD.

SINGLE ASTRAGAL ON HIGH SIDE OF ACTIVE LEAF. E1 STRIKE ON ACTIVE LEAF REQUIRES NOTCH ON ASTRAGAL.

DOUBLE ASTRAGAL ON HIGH SIDE OF ACTIVE LEAF AND LOW SIDE OF INACTIVE LEAF.

1

2

1

2

LOWSIDEAPPL.

STRIKE NOTCH WHEN REQUIRED

GAUGE: 12STEEL TYPE: CR OR GALVANNEAL

1-1/2” (38.1)

1-1/2” (38,1)

FLAT-OFFSET ASTRAGAL AVAILABLE

Page 97: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

90“Z” Astragal Locations and HandingDoor Technical Data

October, 2002

L#6 OVAL HEAD SCREWS(ALSO AVAILABLE WELDED)

RUNS FULL HEIGHT AND ISNOTCHED FOR THE STOP

DOORHEIGHT

5/8” NOTCHEDTO CLEARFRAMESTOP ATHEAD.

REVERSE ANGLE:HARDWARE REINF. TABS FORMED INTEGRAL WITH ASTRAGAL

DOOR EDGE PREPARATION TO RECEIVE ASTRAGAL WITH E1/H1 PREP.

RHACTIVE

LHACTIVE RH ASTRAGAL

RHR ASTRAGAL (LH)LHRACTIVE

RHRACTIVE

LH ASTRAGAL

LHR ASTRAGAL (RH)

BEVELED ASTRAGAL SQUARE ASTRAGAL

ACTIVELEAF

INACTIVELEAF

ACTIVELEAF

INACTIVELEAF

GAUGE: 14STEEL TYPE: GALVANEAL

Page 98: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

91CL Standard Closer Reinforcement

Door Technical DataOctober, 2002

L

14 GA. (1.9) REINFORCING

LEGS OF REINFORCING ARE WELDED TO END CHANNELHINGE EDGE

5-1/4”(133.4)

1”(25.4)

20”(508)

12 GA. (2.6) REINFORCING

LEGS OF REINFORCING ARE WELDED TO END CHANNELHINGE EDGE

5-1/4”(133.4)

1”(25.4)

20”(508)

C2 Optional Closer Reinforcement

L

DOOR SERIES607, 707, 727737, 747

12 GAUGE OPTIONDOOR SERIES707, 727737, 747

Page 99: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

92857 Standard Surface Closer ReinforcementDoor Technical Data

October, 2002

L

HINGE EDGE

LEGS OF REINFORCING ARE WELDED TO END CHANNEL.

16 GA. (1.4)TOP CAP(STANDARD)

12 GA. (2.6) REINFORCING CHANNEL

2” (50.8)

5-1/4”(133.4)

1-1/8”(28.6)

20”(508)

Page 100: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

93Concealed Holder/Closer Reinforcement

Door Technical DataJuly, 2003

L

END CHANNEL IS MODIFIED FOR CORRECT DEPTHDIMENSIONS VARY AS PER TEMPLATE

TOP OF DOOR SKIN AND END CHANNEL ARECUT AWAY PER TEMPLATE

HINGE CHANNEL

LOCK CHANNEL

12 GA. (2.6) REINFORCING

END VIEW

END CHANNEL

DOOR SKIN

MOUNTING HOLES SHALL BE DRILLED AND TAPPED IN THE FIELD FOR DESIRED HOLD OPEN ANGLE.

Page 101: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

94857 Concealed Overhead Stop ReinforcementDoor Technical Data

April, 2002

L

14 GA. (1.9) CONTINUOUS LOCK CHANNEL2”

(50.8)

16 GA. (1.4) TOP CAP

TOP OF DOOR SKIN AND END CHANNEL ARE CUT AWAY PER TEMPLATE

12 GA. (2.6) CONTINUOUS HINGE CHANNEL

END CHANNEL IS MODIFIED FOR CORRECT DEPTH DIMENSIONS VARY AS PER TEMPLATE

SIZE AND TAP PER TEMPLATE

END CHANNEL14 GA. (1.9)

12 GA. (2.6) REIN-FORCEMENT

END VIEW

TOP CAP 16 GA. (1.4)

2” DOOR

Page 102: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

95Semi-Mortise Door Bottom Preparation

Door Technical DataApril, 2002

L

NOTE: CHANNEL DIMENSIONS DETERMINED BY SEMI-MORTISE BOTTOM TEMPLATE.

14 GA. (1.9) OR CHANNEL REINFORCEMENT

14 GA. (1.9) ORCHANNEL REINFORCEMENT

SIZE PER TEMPLATE

PERTEMPLATE

PERTEMPLATE

Page 103: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

96G1 Govt. 160 Reinf. Cylindircal Lock 1-3/8” DoorDoor Technical Data

April, 2002

L

SIZE AND TAP PER ANSI A115.2

14 GA. (1.9) CONTINUOUS CHANNEL

12 GA. (2.6) TABS

16 GA. (1.4)REINFORCING

2-1/4”(57.2)

CL

1”(25.4)

40-5/16” (1023.9) TO STRIKEON FRAME

(STANDARD)

CL

FLOOR

CL

CL

2-3/4” (69.9) BACKSET FROM TO CENTEROF DOOR

CL

FACE PUNCH2-1/8” (53.9)(STANDARD)

4-7/32” (107.2)

3-27/64”(86.9)

NOTE: NO LATCH BOLT GUIDE REQUIRED FOR 1-3/8” DOOR

Page 104: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

97G1A Cylindrical Thru Bolt Preparation 1-3/8” Door

Door Technical DataApril, 2002

L14 GA. (1.9) CONTINUOUS LOCK CHANNEL

16 GA. (1.4) CYLINDRICAL LOCK REINFORCEMENT

NOTE: LEVER HANDLE LOCKS REQUIRING INDEXING HOLES MUST BE SPECIFIED WHEN ORDERING.

1”(25.4)

FACE PUNCH2-1/8” (54.0)(STANDARD)

CLCL

2-1/4”(57.2)

40-5/16” (1024)TO OF STRIKE ON FRAME (STANDARD)

CL

2-3/4” (69.9) BACK-SET

TO OF DOOR EDGE

CL

CL

FLOOR LINE

4-7/32” (107.2)

SIZE AND TAP PER ANSI 115.2

3-27/64”(86.9)

Page 105: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

98G1B Cylindrical Thru Bolt Preparation 1-3/8” DoorDoor Technical Data

April, 2002

L14 GA. (1.9) CONTINUOUS LOCK CHANNEL

16 GA. (1.4) CYLINDRICAL LOCK REINFORCEMENT 1”

(25.4)

CLCL

2-1/4”(57.2)

40-5/16” (1024)TO OF STRIKE ON FRAME (STANDARD)

CL 2-3/4” (69.9) BACK-SET

TO OF DOOR EDGE

CL

CL

FLOOR LINE

4-7/32” (107.2)

SIZE AND TAP PER ANSI 115.2

3-27/64”(86.9)

2-1/8” (54)

3-1/4”(82.5) TYP.

5/16”(7.9) 2 PLS

7/16”(11.0) 4 PLS

45˚

Page 106: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

99G2 Govt. 161 Reinf. Cylindrical Lock 1-3/4” Door

Door Technical DataJune, 2018

L14 GA. (1.9) CONTINUOUS LOCK CHANNEL

16 GA. (1.4) CYLINDRICAL LOCKREINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

2-1/4”(57.2)

CL

1-1/8”(28.6)

FACE PUNCH2-1/8” (54)(STANDARD)

CL

CL

2-3/4” (69.9)BACKSET

40” (1016) TO STRIKEON FRAME

(STANDARD)

FLOOR

CLSIZE AND TAP PER ANSI 115.2

Page 107: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

100857 G2 Govt. 161 Reinf. Cylindrical LockDoor Technical Data

April, 2002

L

SIZE AND TAP PER ANSI 115.2

14 GA. (1.9) CONTINUOUS CHANNEL

12 GA. (2.6) CYLINDRICALLOCK REINFORCEMENT

16 GA. (1.4)REINFORCING

2-1/4”(57.2)

CL

1-1/8”(28.6)

40” (1016) TO STRIKEON FRAME

(STANDARD)

CL

FINISHED FLOOR

CL

CL

2-3/4” (69.9) BACKSET FROM TO CENTEROF DOOR (STANDARD)

CL

FACE PUNCH2-1/8” (53.9)(STANDARD)

2” DOOR

Page 108: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

101G2A Cylindrical Thru Bolt Preparation 1-3/4” Door

Door Technical DataJanuary, 2008

L

HOLE SIZEAND LOCATIONPER TEMPLATE

2-1/4”(57.2)

CL

FACE PUNCH2-1/8” (54)(STANDARD)

CL

CL

2-3/4” (69.9)BACKSET

40” (1016) TO STRIKEON FRAME

(STANDARD)

FLOOR

CL

16 GA. (1.4) CYLINDRICAL LOCKREINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

14 GA. (1.9) CONTINUOUSLOCK CHANNEL

4-7/32” (107.2)

3-27/64”(86.9)

NOTE: LEVER HANDLE LOCKS REQUIRING INDEXING HOLES MUST BE SPECIFIED WHEN ORDERING.

SIZE AND TAP PER ANSI 115.2

Page 109: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

102G2B Cylindrical Thru Bolt Preparation 1-3/4” DoorDoor Technical Data

April, 2002

L

4-7/32” (107.2)

2-1/8” (54)

3-1/4” (82.5) TYP.

3-27/64”(86.9)

5/16” (7.9)2 PLS

7/16” (11)4 PLS

2-1/4”(57.2)

CL

1-1/8”(28.6)

CL

CL

2-3/4” (69.9)BACKSET

40” (1016) TO STRIKEON FRAME

(STANDARD)

FINISHED FLOOR

CL

16 GA. (1.4) CYLINDRICAL LOCKREINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

14 GA. (1.9) CONTINUOUSLOCK CHANNEL

SIZE AND TAP PER ANSI 115.18

45˚

Page 110: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

103G3 Govt. 86 Esch. Trim Mortise Lock Preparation

Door Technical DataApril, 2004

14 GA. (1.9) CONTINUOUSLOCK CHANNEL

L

16 GA. (1.4) REINFORCEMENT

LOCK SUPPORT CLIPS

9.25” (235.0)

4-5/8”(117.5)

8” (203.2)CLOF

PREP.

3/8” (9.5)

1-1/4” (31.8)FOR 1-3/4” (44.5) DOORS1-1/16” (27)FOR 1-3/8” (34.9)

1-1/2” (38.1)FOR 1-3/4” (44.5) DOORS1-9/16” (39.6)FOR 1-3/8” (34.9) DOORS

TAP 12-24

40” (1016) TO STRIKEON FRAME

(STANDARD FOR 1-3/4” (44.5) DOOR)

40-5/16” (1023.9) TO STRIKEON FRAME

(STANDARD FOR 1-3/8” (34.9) DOOR)

CL

CL

FLOOR

INTEGRAL TAB EXTRUDED AND TAPPED TO 12 GA. (2.6)

DOOR FACE AND EDGE PREPARATIONCONFORM TO ANSI A115.1

7-3/16” (182.6)FOR 1-3/4” (44.5) DOORS5-9/16” (141.3)FOR 1-3/8” (34.9) DOORS

Page 111: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

104G3A Sectional Trim Mortise Lock PreparationDoor Technical Data

April, 2004

L

16 GA. (1.4) REINFORCEMENT

14 GA. (1.9) CONTINUOUSLOCK CHANNEL

LOCK SUPPORTCLIPS

4-5/8”(117.5)

9.25” (235.0) CL

OFPREP.

3/8” (9.5)

8” (203.2)

1-1/4” (31.8)FOR 1-3/4” (44.5) DOORS1-1/16” (27)FOR 1-3/8” (34.9) DOORS

FLOOR

40” (1016) TO STRIKEON FRAME

(STANDARD FOR 1-3/4” (44.5) DOOR)

40-5/16” (1023.9) TO STRIKEON FRAME

(STANDARD FOR 1-3/8” (34.9) DOOR)

CL

CL

SECTIONAL TRIM FACE PREPARATION PER TEMPLATE.

SIZE AND TAP EDGE ONLY PER ANSI 115.1

FACE PUNCHPER FUNCTIONTEMPLATE

INTEGRAL TAB EXTRUDED AND TAPPED TO 12 GA. (2.6)

Page 112: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

105G3AEO Edge Only Preparation

Door Technical DataApril, 2013

16 GA. (1.4) REINFORCEMENT

14 GA. (1.9) CONTINUOUSLOCK CHANNEL

LOCK SUPPORTCLIPS

4-5/8”(117.5)

12”(304.8) CL

OFPREP.

3/8” (9.5)

8” (203.2)

1-1/4” (31.8)FOR 1-3/4” (44.5) DOORS1-1/16” (27)FOR 1-3/8” (34.9) DOORS

FLOOR

40” (1016) TO STRIKEON FRAME

(STANDARD FOR 1-3/4” (44.5) DOOR)

40-5/16” (1023.9) TO STRIKEON FRAME

(STANDARD FOR 1-3/8” (34.9) DOOR)

CL

CL

SECTIONAL TRIM FACE PREPARATION PER TEMPLATE.

SIZE AND TAP EDGE ONLY PER ANSI 115.1

FACE PUNCHPER FUNCTIONTEMPLATE

INTEGRAL TAB EXTRUDED AND TAPPED TO 12 GA. (2.6)

L

Page 113: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

106857 G3AEO Govt. 86 Esch. Trim Mortise LockDoor Technical Data

April, 2002

L

40” (1016) TO STRIKEON FRAME

(STANDARD)

CL

FINISHED FLOOR

8” (203.2)

CL

1-1/4” (28.6)

12 GA. (2.6)REINFORCEMENT

OFPREP.

3/8”(9.5)

TAP 12-24

16 GA. (1.4)LOCK CENTERING CLIPS

12 GA. (2.6)CHANNEL REINFORCEMENT

14 GA. (1.9)CONTINUOUS LOCK CHANNEL

12” (304.8)

4-3/4” (120.6)

DOOR EDGE PREPARATIONCONFORM TO ANSI A115.1

2” DOOR

Page 114: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

107G6 Unit Lock Reinforcement

Door Technical DataApril, 2002

L14 GA. (1.9) 2 PIECE LOCK CHANNEL

16 GA. (1.4) CHANNEL REINFORCEMENT

PER TEMPLATE

PER TEMPLATE

CL

PER TEMPLATE

FLOOR

40” (1016) TO STRIKEON FRAME

(STANDARD FOR 1-3/4” (44.5) DOOR)

40-5/16” (1023.9) TO STRIKEON FRAME

(STANDARD FOR 1-3/8” (34.9) DOOR)

CL

CLNOTE: SPECIFY HARDWARE MANUFACTURER AND MODEL NUMBER.

Page 115: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

108G11 Rim Exit ReinforcementDoor Technical Data

March, 2007

L

14 GA. (1.9)CHANNELREINFORCEMENT

18”(457.2)(STD)

12”(304.8)(STD)

4-7/8”(123.8)(STD)

4-11/16”(119)(STD)

28”(711.2)(STD)

34”(863.6)(STD)

FINISHED FLOOR

BLANK FACE STANDARD

NOTE:FACE PREPARATION AND REINFORCEMENT PERTEMPLATE WHEN SPECIFIED.

LOCKSIDE

Page 116: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

109G11A, G11B, G11C Rim Vertical Rod Exit Reinforcement

Door Technical DataMarch, 2007

L

14 GA. (1.9)CHANNEL REINFORCEMENT

NOTE:TOP AND BOTTOM ROD PREPARATION PER TEMPLATE.

14 GA. (1.9)CHANNELREINFORCEMENT

18”(457.2)(STD)

12”(304.8)(STD)

4-1/8”(104.8)(STD)

3-3/16”(96.8)(STD)

BLANK FACE STANDARD

NOTE:

FACE PREPARATION AND REINFORCEMENT PERTEMPLATE WHEN SPECIFIED.

27”(685.8)(STD)

33”(838.2)(STD)

FINISHED FLOOR

6” (152.4)(STD)

6” (152.4)(STD)

LOCKSIDE

G11B - 3 POINT LATCHING IS REIN-FORCED THE SAME AS G11A SHOWN

G11C - TOP LATCH ONLY. BOTTOM LOCK SIDE REINFORCING CHANNEL IS OMITTED.

14 GA. (1.9)CHANNEL

REINFORCEMENT

FIRE PLUNGER REQUIRED FOR LABEL.

Page 117: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

110G12 Mortise Exit ReinforcementDoor Technical Data

March, 2007

L

1-1/4”(31.8)(STD)

MOUNTING TABS EXTRUDED AND TAPPED TO 12 GA.

14 GA. (1.9)CHANNELREINFORCEMENT

18”(457.2)(STD)

12”(304.8)(STD)

4-1/8”(104.8)(STD)

3-3/16”(96.8)(STD)

BLANK FACE STANDARD

NOTE:

FACE PREPARATION ANDREINFORCEMENT PER TEMPLATE WHEN SPECIFIED

27”(685.8)(STD)

33”(838.2)(STD)

FINISHED FLOOR

* LOCATE PER TEMPLATE ON PAIRS WITH EXIT DEVICE ON BOTH DOORS.

8”(203.2)(STD)

CL

40” (1016) TO STRIKEON FRAME*

(STD)

CL

LOCKSIDE

Page 118: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

111G12A, G12B, G12C Concealed Vertical Rod

Door Technical DataMarch, 2007

L

NOTE:TOP AND BOTTOM ROD PREPARATION PER TEMPLATE.

14 GA. (1.9)CHANNELREINFORCEMENT

18”(457.2)(STD)

12”(304.8)(STD)

4-1/8”(104.8)(STD)

3-3/16”(96.8)(STD)

27”(685.8)(STD)

33”(838.2)(STD)

FINISHED FLOOR

OPEN SPACE FOR VERTICAL ROD

NOTE: FINISH FLOOR, BOTTOM UNDERCUT, AND BOLT PROTRUSION CRITICAL FOR BOLT ENGAGEMENT TO FLOOR.

LOCK SIDE

G12B - LESS BOTTOM ROD. BOTTOM ROD PREPARATION IS OMITTED.

G12C - LESS BOTTOM ROD. BOT-TOM ROD PREP. IS OMITTED. FIRE PLUNGER REQUIRED FOR LABEL.

REINFORCE, DRILL, TAP PER TEMPLATE

BLANK FACE STANDARD

NOTE:

FACE PREPARATION AND REINFORCEMENT PER TEMPLATE WHEN SPECIFIED

Page 119: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

112G13B SARGENT Recessed Latch Top and Mortise Lock (LBR)Door Technical Data

May, 2006

L14 (1.9) GA. REINFORCEMENT

TOP ROD PREPARATION

CL

41”(1041.4)

FLOOR LINE

A

A

NOMINALCUTOUT WIDTH DOOR WIDTH *30-5/32” (765.9) 3’0” (914.4) ONLY36-5/32” (918.3) 3’6” (1066.8) OR 3’8” (1117.6)40-5/32” (1019.9) 3’10” (1168) OR 4’0” (1219.2), 4’0” (1219.2) -5’0” (1524)

*STANDARD HINGE AND LOCK CLEARANCES

THE DEVICE IS FIRE RATED UP TO 90 MINUTES IN DOORS UP TO 4’0” (1219.2) X 10’0” (3048)(SINGLES) AND 8’0” (2438.4) X 10’0” (3048) (PAIRS).

SECTION A–A

16 (1.4) GA. REINFORCEMENT

12 (2.6) GA. REINFORCEMENT

1/4”(6.3) RETURN FORMEDIN SKIN

2-9/32” (57.9)

Page 120: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

113G13 “VON DUPRIN” Recessed Latch Top and Mortise Lock (LBR)

Door Technical DataApril, 2004

L

CL

39-5/8”(1006.4)

FLOOR LINE

A

A NOMINALCUTOUT WIDTH DOOR WIDTH, W *24-5/32” (613.6) 2’6” (762.0) < W < 2’10” (863.6)30-5/32” (765.9) 2’10” (863.6) < W < 5’0” (1524)

THE DEVICE IS FIRE RATED UP TO THREE HOURS IN DOORS UP TO 4’0” (1219.2) X 10’0” (3048) (SINGLES).

* STANDARD HINGE AND LOCK CLEARANCES

1-3/4” DOOR ONLYNOT AVAILABLE ON:EMBOSSED PANEL DOORS20 (.91) GAUGE DOORS607 SERIES DOORS737 SERIES DOORS2” (50.8) THICK DOORS

SECTION A–A

7 (4.5) GA. REINFORCEMENT

1/4” (6.3)RETURN FORMEDIN SKIN

4-1/4” (107.9)

16 (1.4) GA. REINFORCEMENT

CL 8-1/2”(215.9)

Page 121: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

114G13A “VON DUPRIN” Recessed Vertical Rod Exit DeviceDoor Technical Data

April, 2004

L7 (4.5) GA. REINFORCEMENT

TOP ROD PREPA-RATION

CL

39-5/8”(1006.4)

FLOOR LINE

A

A NOMINALCUTOUT WIDTH DOOR WIDTH, W *24-5/32” (613.6) 2’6” (762.0) < W < 2’10” (863.6)30-5/32” (765.9) 2’10” (863.6) < W < 5’0” (1524)

THE DEVICE IS FIRE RATED FOR USE ON PAIRS UP TO 8’0” X 10’0”, 3 HOURS DOUBLE EGRESS DOORS AND 90 MINUTE DOORS SWINGING IN THE SAME DIRECTION.

* STANDARD HINGE AND LOCK CLEARANCES

1-3/4” (44.4) DOOR ONLYNOT AVAILABLE ON:EMBOSSED PANEL DOORS 20 (.91) GAUGE DOORS607 SERIES DOORS737 SERIES DOORS2” (50.8) THICK DOORS

SECTION A–A

7 GA. (4.5)REINFORCEMENT

1/4” (6.3)RETURN FORMEDIN SKIN

4-1/4” (107.9)

16 (1.4)GA. REINFORCEMENT

BOTTOM ROD PREPA-RATION

Page 122: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

115G16 Cylindrical Deadlock Preparation

Door Technical DataApril, 2002

L

1-1/8” STANDARD(28.6)

CONTINUOUS LOCK CHANNEL

16 GA. (1.4) CYLINDRICAL LOCKREINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

2-1/4”(57.2)

CL

CL

CL

2-3/4” (69.9)

BACKSET

FACE PUNCH1-1/2” (38.1) (STANDARD)

48” (1219.2) TO STRIKEON FRAME

(STANDARD)

CL

FLOOR

SIZE AND TAP PER TEMPLATE

Page 123: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

116G2 Lock G16 Deadlock Combination (G25)Door Technical Data

April, 2002

L

4” (101.2)MIN.

CONTINUOUS LOCK CHANNEL

16 GA. (1.4) CYLINDRICALLOCK REINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

SIZE AND TAP PER TEMPLATE

16 GA. (1.4) CYLINDRICALLOCK REINFORCEMENT

16 GA. (1.4) LATCHBOLT GUIDE

2-1/4”(57.2)

2-1/4”(57.2)

CL

CL

1-1/8”(28.6)

1-1/8”(28.6)

CL

CL

CL

FACE PUNCH1-1/2” (38.1)(STANDARD)

FACE PUNCH2-1/8” (54)(STANDARD)

FINISHED FLOOR

40” (1016) TO STRIKE ON FRAME

(STANDARD)

CL

Page 124: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

117G17 Mortise Deadlock Preparation

Door Technical DataApril, 2013

L

48” (1219.2) TO STRIKEON FRAME

(STANDARD)

CL

FINISHED FLOOR

14 GA. (1.7) CHANNEL REINFORCEMENT

LOCK SUPPORT CLIPS

4-5/8” (117.5)

12” (304.8)

CONTINUOUS LOCK CHANNEL

PER TEMPLATE

CL

PERTEMPLATE

12 GA. (2.6)REINFORCEMENT

FACE PUNCHPER FUNCTION

TEMPLATE

TRIM HOLESNOT PUNCHED

Page 125: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

118857 G30 Door Mounted Pocket LockDoor Technical Data

February, 2016

LLOCK PREPARATION IS FOR COVER PLATE TO BE SURFACE AP-PLIED.COVER PLATE IS FURNISHED BY OTHERS.

STANDARD CURRIES BACKSETLOCATION IS FOR POCKETLOCK MOUNTED ONMOUNTING PLATE WITHOUT SHIMS.

12 GA. (2.6)REINFORCEMENT

(BLANK - NO DRILL AND TAP)

CUT OUTPER TEMPLATE

CUT OUTPER TEMPLATE

2”(50.8)

PERTEMPLATE

PERTEMPLATE

2” DOOR

Page 126: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

119G18 Push Pull Reinforcement

Door Technical DataApril, 2002

L

14 GA. (1.9) CHANNEL REINFORCEMENT

33”(838.2)

FLOOR LINE

25”(635)

4-5/8”(117.5)

Page 127: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

120Flush Bolt Preparation (H1)Door Technical Data

April, 2011

L

CL

(H1)12” (304.8)

FROMTOP/BOTTOM OF DOOR STANDARD

(H124)24” (609.6) FROM TOP12” (304.8)

FROM BOTTOM

(H136)36” (914.4) FROM TOP12” (304.8)

FROM BOTTOM

CL

6-3/4”(171.5)

13/16”(.81)

1-1/16”(25.46)

TABS FORMED INTEGRAL WITH LOCK CHANNEL

PIERCE AND EXTRUDEMOUNTING HOLES

NOTES1. MORTISE AND TAP PER ANSI/BHMA A156.1152. REINFORCED IN ACCORDANCE WITH ANSI A250.6

Page 128: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

121857 H1 ANSI Mortise Flush Bolt Preparation

Door Technical DataApril, 2002

L

CL

CL

(H1)12” (304.8)

FROMTOP/BOTTOM

OF DOOR STANDARD

(H124)24” (609.6) FROM TOP 12” (304.8)

FROM BOTTOM

(H136)36” (914.4) FROM TOP 12” (304.8)

FROM BOTTOM

6-3/4”(171.5)

SIZE AND TAP PER ANSI 115.4

12 GA. (2.6) REINFORCING

1”(25.4)

2”(50.8)

2” DOOR

Page 129: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

122(SB) Surface Bolt ReinforcementDoor Technical Data

April, 2002

L

12”(304.8)

4-13/16”(122.2)

14 GA. (1.9)CHANNEL REINFORCEMENT

7/8”(22.2)

12”(304.8)

4-13/16”(122.2)

14 GA. (1.9)CHANNEL REINFORCEMENT

7/8”(22.2)

Page 130: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

123Notes

Door Technical Data

Page 131: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

124Bi-Fold DoorsDoor Technical Data

December, 2012

L 2 PAIR

1/16” (1.6)

1/16” (1.6)

1/16” (1.6)

1/16” (1.6)

1/4” (6.3)

NET DOOR

DOOR A DOOR B DOOR C DOOR D

DOOR A DOOR B DOOR C DOOR D

DOOR A DOOR B DOOR C DOOR D

NET DOOR NET DOOR NET DOOR

RHLH LH RH

LR LR RR RR

STANDARD CLEARANCES SHOWN WITH SQUARE EDGE DOORS AND MORTISE HINGES. HARDWARE APPLICATIONS CAN CHANGE STILES, BEVELS, AND BOTTOM UNDERCUT. ALWAYS ADVISE FACTORY OF FRAME SIZE AND COMPLETE HARDWARE SET WHEN ORDERING.

FRAME OPENING

Page 132: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

125CURRIStain (A1) Door and “h” Astragal

Door Technical DataNovember, 2018

Steel code - A118 (1.1) or 16 (1.3) gauge galvanneal steel with .005” deep oak wood grain embossment. Available 707 or 727 series “S” edge seam only.4090 (1219 x 2743.2) max. door size for 707.4080 (1219 x 2438.4) max. door size for 727.Type 1 and Type 2 window kits available.

CURRIStain Finish ColorsNatural CocoaWheat CabernetCashew Java

Custom Color MatchCustom stain color matching is available. Send physical sample to be matched to your Customer Service Professional. Additional lead-times may apply.

“h” astragal 18 (1.1) gauge woodgrain embossment (code k). Inactive leaf preparations only! Blank, strike (E1), and or flush bolt (H1) preparations. Screw applied available for CURRIStain door only. 90 (2743.2) maximum height will fit both beveled edge and square edge doors.

CURRIStain Astragal (code k)

Stain – Stains used are solvent based products. Uniform application of stain by spraying 1 mil thickness over the entire door surface area and removing the excess stain by brushing or wiping the surface to obtain the desired color and effect. Six standard color choices are available (natural, wheat, cashew, cocoa, cabernet, or java). Custom color matching available for virtually any color.

Topcoat – A urethane with UV inhibitors topcoat is spray applied evenly across the surfaces. This UV resistant topcoat provides excellent resistance to normal wear and abuse. This topcoat is proven to be a solid performer for exterior as well as interior installations. The coating system was successfully tested to ANSI Standard A250.3.

Warranty – CURRIES steel doors have a warranty for one year on materials and craftsmanship after deliv¬ery to the jobsite. CURRIStain factory finish products include this one year warranty. Incidental nicks and scratched may be repaired using touch up “pens” available from the CURRIES factory.

Note: Substitute door series 727 for 707 when temperature rise listed openings are required. 727 doors use a “temperature rise core” in lieu of polystyrene or polyurethane core.

Specifications – Stainable wood grained steel doors shall be as manufactured by CURRIES, Mason City, Iowa. Doors shall be 707 series construction with continuous hinge and lock channel construction the full height of the door. Hinge and lock mounting preparations are integrally formed into these channels. Inverted top and bottom channel construction provides a full perimeter channel door infrastructure with door face skins supported by either a polystyrene core or polyurethane core permanently bonded to the face skins as required for insulating values on all openings. Doors shall be manufactured of galvanneal steel for corrosion resistance. Door face skins are grained .005 deep to accent the color stain application requested by the building owner. Doors are available handed as single doors or pairs of doors with or without fire resistance ratings. Doors are factory stained and sealed with the owner’s choice of CURRIES standard colors.

Page 133: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

126Window Kit Pocket SizesDoor Technical Data

July, 2014

GLASS THICKNESS POCKET SIZE TYPE 1 AND 2 CURRIES AND WOODGRAIN KITS

0.1875” to 0.25” Standard Pocket 0.3750”

0.3125” to 0.50” Special Pocket 0.6250”

0.5625” to 0.75” Special Pocket 0.8750”

0.8125” to 1.00” Special Pocket 1.1250”

TYPE 3 KIT0.25” Standard Pocket 0.375”

0.375” Special Pocket 0.50”

0.50” Special Pocket 0.625”

TYPE 4 KIT0.25” Standard Pocket 0.375”

0.375” Special Pocket 0.50”

0.50” Special Pocket 0.625”

0.625” Special Pocket 0.75”

0.75” Special Pocket 0.875”

0.875” Special Pocket 1.00”

1.00” Special Pocket 1.125”

TYPE 7 KIT0.25” Standard Pocket 0.375

0.375” Special Pocket 0.50”

0.5” Special Pocket 0.625”

0.625” Special Pocket 0.750”

0.75” Special Pocket 0.875”

TYPE 8 KIT0.25” Standard Pocket 0.375

0.375” Special Pocket 0.50”

0.50” Special Pocket 0.625”

0.625” Special Pocket 0.75”

0.75” Special Pocket 0.875”

0.875” Special Pocket 1.00”

1.00” Special Pocket 1.125”

1.125” Special Pocket 1.250”

1.25” Special Pocket 1.375”

1.375” Special Pocket 1.50”

1.50” Special Pocket 1.625”

TYPE 9 AND 10 ASSA KITS0.1875” to 0.3125” Standard Pocket 0.375”

0.375” to 0.50” Special Pocket 0.5625”

0.5625” to 0.75” Special Pocket 0.8125”

0.8125” to 1.00” Special Pocket 1.0625”

Page 134: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

127Glass Moulding Type 7

Door Technical DataMay, 2013

L

Glass Moulding Type 8

* POCKET SIZE 3/8” (9.5), 1/2” (12.7), 5/8” (15.9), 3/4” (19.1), 7/8” (22.2), FOR 1-3/4” (44.45) DOORS 3/8” (9.5) THROUGH 1-1/8” (28.6) IN 1/8” INCREMENTS FOR 2” (50.8) DOORS

5/8” (15.9),3/4” (19),1” (25.4) OR1-1/4” (31.8)

* POCKET SIZE 3/8” (9.5), THROUGH 1-5/8” (41.3) FOR 1-3/4” (44.5) DOORS 3/8” (9.5) THROUGH 1-7/8” (47.6) IN 1/8” INCREMENTS FOR 2” (50.8) DOORS

5/8” (15.9),3/4” (19),1” (25.4) OR1-1/4” (31.8)

TYPE 7

TYPE 8

14 GA.

14 GA. *

*

GLASS THICKNESS PLUS.125 = POCKET

GLASS THICKNESS PLUS.125 = POCKET

CALL FACTORY FOR GLASSAND CUTOUT SIZE

CALL FACTORY FOR GLASSAND CUTOUT SIZE

Page 135: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

128G13C “VON DUPRIN” Recessed Vertical Rod Exit Device (LBR)Door Technical Data

June, 2004

L7 (4.5) GA. REINFORCEMENT

TOP ROD PREPARATION

CL

39-5/8”(1006.4)

FLOOR LINE

A

A NOMINALCUTOUT WIDTH DOOR WIDTH, W *24-5/32” (613.6) 2’6” (762.0) < W < 2’10” (863.6)30-5/32” (765.9) 2’10” (863.6) < W < 5’0” (1524)

THE DEVICE IS FIRE RATED FOR USE ON PAIRS UP TO 8’0” X 10’0”, 3 HOURS DOUBLE EGRESS DOORS AND 90 MINUTE DOORS SWINGING IN THE SAME DIRECTION.

* STANDARD HINGE AND LOCK CLEARANCES

1-3/4” (44.4) DOOR ONLYNOT AVAILABLE ON:EMBOSSED PANEL DOORS 20 (.91) GAUGE DOORS607 SERIES DOORS737 SERIES DOORS2” (50.8) THICK DOORS

SECTION A–A

7 GA. (4.5)REINFORCEMENT

1/4” (6.3)RETURN FORMEDIN SKIN

4-1/4” (107.9)

16 (1.4)GA. REINFORCEMENT

7/8” (22.2) DIA.PLUNGER HOLE

Page 136: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

129ElectroLynxTM System

Door Technical DataAugust, 2017

LLO

CK E

DGE

HING

E ED

GE

3 HI

NGE

DOOR

4 HI

NGE

DOOR

5 HI

NGE

DOOR

HARDWARELOCATION

12” (304.8)

CL

3/4” (19) *

6” (152.4) 6” (152.4)

2” (50.8) *

6” (152.4)FULL GLASS & STEEL RIBBED DOOR ROUTE

CABLEROUTINGAREA

EXCESSCABLEAREA

VERIFY CABLE LOCATION BEFORE MODIFYING DOOR OR SURFACE AP-PLICATION OF HARDWARE.

* BASED ON 3/4” (19) END CHANNEL DEPTH. VARIES FOR HARDWARE MOUNTED IN BOTTOM OF DOOR (EG-DOOR BOTTOMS).

** MINIMUM OF THREE HINGES WHEN ELECTROLYNX CABLE IS ORDERED. STANDARD LOCATION SHOWN. SOME HARDWARE AND TRIM COMBINATIONS WILL REQUIRE MULTIPLE ELECTROLYNX CABLES. ADDITIONAL ELECTRIC HINGE PREPARATIONS FOR MULTIPLE ELECTOLYNX CABLES ARE REQUIRED.

AVAILABLE IN THESE CUR-RIES DOOR SERIES707 757727 777737 847747 857

CAUTION IS RECOMMENDED WHEN INSTALLING SURFACE APPLIED HARDWARE IN AREAS HOLDING SYSTEM WIRING.

THE CURRIES ELECTROLYNX CABLE IS EQUIPPED WITH THE ELECTROLYNX SYSTEM OF PLUG IN CONNECTORS FOR FAST, EASY, CONNECTION TO SIMILARLY EQUIPPED ASSA ABLOY HARDWARE.

THE ELECTROLYNX CABLE HAS 12 CONDUCTORS OF 22 GA. WIRE IN A JACKET, WITH ELECTROLYNX CONNECTORS ON THE HARDWARE PREP END ONLY.

POWER OVER ETHERNET (POE) CABLES ARE ALSO AVAILABLE.

NEITHER CABLE WILL FIT OUR RACEWAY. RACEWAY IS INTENDED FOR PULLING NONJACKETED INDIVIDUAL CONDUCTORS.

SINGLE CABLE

MULTIPLE CABLES

**

**

**

**

**

ELECTRIC HINGE LOCATION

ELECTRIC HINGE LOCATION

ELECTRIC HINGE LOCATION

ELECTRIC HINGE LOCATION

ELECTRIC HINGE LOCATION

Page 137: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

130NotesDoor Technical Data

Page 138: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

131Glass Moulding Type 11

Door Technical DataAugust, 2013

L

THIS SURFACE PUNCHED AND COUNTERSUNK, ON CENTER, FOR #6-20 OVAL HEAD SCREW.

GLASS THICKNESS PLUS .125 = POCKETGLASS SIZE IS 1” LARGER THAN VISIBLEREMOVABLE SIDE CUTOUT SIZE IS 1-1/4” LARGER THAN VISIBLE

REMOVABLE MOULDING

NOTE:REMOVABLE MOULDING IS ALWAYS ON THE INTERIOR SIDE UNLESS NOTED DIFFER-ENTLY ON THE ORDER.

DOOR SKIN

MOULDING WELDED

3/8” (9.5), 1/2” (12.7), AND 5/8” (15.8) POCKETS ONLY1-3/4” (44.5) DOORS ONLY

*

*

*

**

3-1/8” (79.3) MINIMUM STILE AND RAIL AVAILABLE WITH TYPE 11 MOULDING. “NO FIRE LISTING,” LIMITED HARDWARE.

*

VARIES#6 SCREW

REMOVABLE STOP(18 GA.) 5/8” (15.9) X 5/8” (15.9)

5/8” (15.9)

18 GA.*SPOT WELD * SPOT

WELD

Page 139: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

132NotesDoor Technical Data

Page 140: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

133767 Stile and Rail Door

Door Technical DataJune, 2013

L

• 16 GA. INSULATED TUBULAR STEEL• FLUSH TOP• CONTINUOUSLY WELDED CORNERS• FLUSH GLAZING• 5-5/8” STILES AND TOP RAIL (OPTIONAL 3-5/8” and 7-5/8”)• 12-5/8” BOTTOM RAIL (OPTIONAL 10-5/8”, 14-5/8” OR 16-5/8”)• OPTIONAL CENTER RAIL• BEVELED LOCK & HINGE EDGE

NOTE: RACEWAYS, ELECTRIC HINGES, OR EPT PREPS ARE NOT ALLOWED

Page 141: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

134767 Stile and Rail DoorDoor Technical Data

June, 2013

L

TOP RAIL – FLUSH SEAMLESS DESIGN, 5-5/8” RAIL STANDARD, 3-5/8” RAIL AND 7-5/8” OPTIONALOPTIONAL CENTER RAIL – FLUSH SEAMLESS DESIGN, 5-5/8” RAIL STANDARD, 3-5/8” RAIL AND 7-5/8” OPTIONALBOTTOM RAIL – FLUSH SEAMLESS DESIGN, 12-5/8” BOTTOM RAIL STANDARD, 10-5/8”, 14-5/8” OR 16-5/8” RAIL OPTIONAL

CYLINDRICAL LOCK(ANSI A115.2)

2-3/4” BACKSETGOV. 160/161

MORTISE LOCK(ANSI A115.1)

2-3/4” BACKSETGOV. 86

HINGE PREPARATION4-1/2” OR 5” HIGH STAN-

DARD OR HEAVY WEIGHT, FULL MORTISEANSI A156.7,

HANDED

FLUSH GLAZINGINTEGRAL FLUSH GLAZING WITH

REMOVABLE GLASS BEAD

Page 142: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

135Wicket Doors

Door Technical DataApril, 2006

L14 GA. (1.9) CHANNEL SURROUND FLUSH WITH SEAM EDGE NEXT TO SKINS

• DOOR IN A DOOR - 2 DOORS

• USE NEXT SIZE DOOR UP FOR EACH DOOR.

• LARGER DOOR MUST BE 747 CONSTRUCTION.

• MOST HINGE AND LOCK PREPARATIONS ARE AVAILABLE.

• EACH WICKET DOOR ASSEMBLY MUST BE ENGINEERED FOR PRACTICAL APPLICATION

AND CLEARANCES TO ENSURE QUALITY PRODUCT SATISFACTION.

MAN DOOR PASS THRU DOOR

Page 143: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

136Wicket Door HandingDoor Technical Data

April, 2006

L

Page 144: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

137747 2-1/4” Thick Door

Door Technical DataJuly, 2009

LSTANDARD HINGE BACKSET

2-7/16”(62)

1/8” (3.2) CLEARANCE

1/2” (12.7)

2-1/4” (57)

1/16” (1.6) REVEAL

5/8” (15.9)

2-1/4” DOOR“G” BEVEL DOOR SHOWN

NOTE: TYPE 3 AND 4 CONCEALED MOULDING ONLY

Page 145: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

138Glass Sizes (Visible) and Lite Locations FVDoor Technical Data

February, 2010

L

FV 10” (254) X 10” (254)

FV1 12” (304.8) X 12” (304.8)

FLOORLINE

FV

CL

CL

EQUALEQUAL

65”(1651)

Type 9 & 10 Window Moulding

Page 146: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

139Glass Sizes (Visible) and Lite Locations FNV

Door Technical DataFebruary, 2009

L

48” (1219.2)FNV2

6-1/4”(158.8)

16” (406.4)FNV

36” (914.4)FNV1

54” (1371.6)FNV3

6”(152.4)

VARIESVARIES

VARIES

VARIES

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS 7’2” (2184.4) AND UNDER

48” (1219.2)FNV2

6-1/4”(158.8)

VARIES

16” (406.4)FNV

36” (914.4)FNV1

54” (1371.6)FNV3

6”(152.4)

24”(609.6)

30” (762)

42”(1066.8)

62”(1574.8)

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS OVER 7’2” (2184.4)

8-1/4” (209.6)

Type 9 & 10 Window Moulding

Page 147: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

140Glass Sizes (Visible) and Lite Locations FNVDoor Technical Data

February, 2009

L6-1/4”(158.8)

8-1/4” (209.6)

33”(838.2)

3”(76.2)

VARIES

FNV4

6-1/4”(158.8)

8-1/4” (209.6)

24”(609.6)

4”(101.6)

VARIES

FNV5

6-1/4”(158.8)

8-1/4” (209.6)

20”(508)

5”(127)

VARIES

FNV6

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

FINISHED FLOOR

Type 9 & 10 Window Moulding

Page 148: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

141Glass Sizes (Visible) and Lite Locations FNV

Door Technical DataFebruary, 2009

L6-1/4”(158.8)

8-1/4” (209.6)

24”(609.6)

6”(152.4)

VARIES

FNV7

6-1/4”(158.8)

8-1/4” (209.6)

30”(762)

6”(152.4)

VARIES

FNV8

6-1/4”(158.8)

8-1/4” (209.6)

25”(635)

4”(101.6)

VARIES

FNV9

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

FINISHED FLOOR

Type 9 & 10 Window Moulding

Page 149: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

142Glass Sizes (Visible) and Lite Locations 2FNVDoor Technical Data

February, 2009

L

48” (1219.2)2FNV2

6-1/4”(158.8)

8-1/4” (209.6)

16” (406.4)2FNV

36” (914.4)2FNV1

54” (1371.6)2FNV3

6”(152.4)VARIES

VARIES

VARIES

VARIES

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS 7’2” (2184.4) AND UNDER

6-1/4”(158.8)

6”(152.4)

48” (1219.2)2FNV2

6-1/4”(158.8)

VARIES

16” (406.4)2FNV

36” (914.4)2FNV1

54” (1371.6)2FNV3

6”(152.4)

24”(609.6)

* NOTE LIMITATIONS OF LABEL IF L TO BE USED

FINISHED FLOOR

STANDARD LOCATIONS FOR DOORS OVER 7’2” (2184.4)

6-1/4”(158.8)

6”(152.4)

30”(762)

42”(1066.8)

62”(1574.8)

Type 9 & 10 Window Moulding

Page 150: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

143Glass Sizes (Visible) and Lite Locations 2FNV

Door Technical DataFebruary, 2009

L6-1/4”(158.8)

8-1/4” (209.6)

33”(838.2)

3”(76.2)

VARIES

* 2FNV4

STANDARD LOCATIONS FORDOORS 7’2” (2184.4) AND UNDER

FINISHED FLOOR

6-1/4”(158.8)

3”(76.2)

6-1/4”(158.8)

8-1/4” (209.6)

24”(609.6)

4”(101.6)

VARIES

6-1/4”(158.8)

4”(101.6)

* 2FNV56-1/4”(158.8)

8-1/4” (209.6)

20”(508)

5”(127)

VARIES

6-1/4”(158.8)

* 2FNV6

5”(127)

FINISHED FLOOR

* MINIMUM 6” (152.4) STILES TO BE LABEL APPROVED

Type 9 & 10 Window Moulding

Page 151: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

144Glass Sizes (Visible) and Lite Locations 2FNVDoor Technical Data

February, 2009

L6-1/4”(158.8)

VARIES

33”(838.2)

3”(76.2)

45”(1103)

* 2FNV4

STANDARD LOCATIONS FORDOORS OVER 7’2”

FINISHED FLOOR

6-1/4”(158.8)

3”(76.2)

6-1/4”(158.8)

VARIES

24”(609.6)

4”(101.6)

54”(1323)

6-1/4”(158.8)

4”(101.6)

* 2FNV56-1/4”(158.8)

VARIES

20”(508)

5”(127)

58”(1421)

6-1/4”(158.8)

* 2FNV6

5”(127)

FINISHED FLOOR

* MINIMUM 6” (152.4) STILES TO BE LABEL APPROVED

Type 9 & 10 Window Moulding

Page 152: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

145Glass Sizes (Visible) and Lite Locations HG, HG2

Door Technical DataFebruary, 2009

L6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

HG

6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES (EQUAL)

HG2

L L

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-5/16” (287.3)

2’4” (711.2) 15-5/16” (388.9)

2’6” (762) 17-5/16” (439.7) 6’8” (2032) 27-1/4” (692.1)

2’8” (812.8) 19-5/16” (490.5)

2’10” (863.6) 21-5/16” (541.3)

3’0” (914.4) 23-5/16” (592.1) 7’0” (2133.6) 31-1/4” (793.8)

3’4” (1016) 27-5/16” (693.7)

3’6” (1066.8) 29-5/16” (744.5)

3’8” (1117.6) 31-5/16” (795.3) 7’2” (2184.4) 33-1/4” (844.6)

3’10” (1168.4) 33-5/16” (846.1)

4’0” (1219.2) 35-5/16” (896.9)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-5/16” (287.3)

2’4” (711.2) 15-5/16” (388.9)

2’6” (762) 17-5/16” (439.7) 6’8” (2032) 13-3/16” (335)

2’8” (812.8) 19-5/16” (490.5)

2’10” (863.6) 21-5/16” (541.3)

3’0” (914.4) 23-5/16” (592.1) 7’0” (2133.6) 15-3/16” (385.8)

3’4” (1016) 27-5/16” (693.7)

3’6” (1066.8) 29-5/16” (744.5)

3’8” (1117.6) 31-5/16” (795.3) 7’2” (2184.4) 16-3/16” (411.2)

3’10” (1168.4) 33-5/16” (846.1)

4’0” (1219.2) 35-5/16” (896.9)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

44-3/8” (1127.1)44-3/8” (1127.1)

SEE MUNTIN BAR

FINISHED FLOOR

Type 9 & 10 Window Moulding

Page 153: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

146Glass Sizes (Visible) and Lite Locations HG2, HG4Door Technical Data

May, 2014

6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES (EQUAL)

HG3

6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES (EQUAL)

HG4

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-5/16” (287.3)

2’4” (711.2) 15-5/16” (388.9)

2’6” (762) 17-5/16” (439.7) 6’8” (2032) 8-1/2” (215.9)

2’8” (812.8) 19-5/16” (490.5)

2’10” (863.6) 21-5/16” (541.3)

3’0” (914.4) 23-5/16” (592.1) 7’0” (2133.6) 9-53/64” (249.6)

3’4” (1016) 27-5/16” (693.7)

3’6” (1066.8) 29-5/16” (744.5)

3’8” (1117.6) 31-5/16” (795.3) 7’2” (2184.4) 10-1/2” (266.7)

3’10” (1168.4) 33-5/16” (846.1)

4’0” (1219.2) 35-5/16” (896.9)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 5-7/32” (132.6)

2’4” (711.2) 7-7/32” (183.4)

2’6” (762) 8-7/32” (208.8) 6’8” (2032) 13-3/16” (335)

2’8” (812.8) 9-7/32” (234.2)

2’10” (863.6) 10-7/32” (259.6)

3’0” (914.4) 11-7/32” (285) 7’0” (2133.6) 15-3/16” (385.8)

3’4” (1016) 13-7/32” (335.8)

3’6” (1066.8) 14-7/32” (361.2)

3’8” (1117.6) 15-7/32” (386.6) 7’2” (2184.4) 16-3/16” (411.16)

3’10” (1168.4) 16-7/32” (412)

4’0” (1219.2) 17-7/32” (437.4)

VARIES (EQUAL)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

SEE MUNTIN BAR

FINISHED FLOOR

44-3/8” (1127.1) 44-3/8” (1127.1)

Type 9 & 10 Window MouldingL

Page 154: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

147Glass Sizes (Visible) and Lite Locations HG6, HG9

Door Technical DataMay, 2014

L6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES (EQUAL)

HG6

6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES (EQUAL)

HG9

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 3-9/64” (79.8)

2’4” (711.2) 4-29/64” (113.1)

2’6” (762) 5-9/64” (130.6) 6’8” (2032) 8-1/2” (215.9)

2’8” (812.8) 5-53/64” (148)

2’10” (863.6) 6-29/64” (164)

3’0” (914.4) 7-9/64” (181.4) 7’0” (2133.6) 9-53/64” (249.6)

3’4” (1016) 8-29/64” (214.7)

3’6” (1066.8) 9-9/64” (232.2)

3’8” (1117.6) 5-53/64” (148) 7’2” (2184.4) 10-1/2” (266.7)

3’10” (1168.4) 10-29/64” (265.5)

4’0” (1219.2) 11-9/64” (283)

VARIES (EQUAL)VARIES (EQUAL)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 5-7/32” (132.6)

2’4” (711.2) 7-7/32” (183.4)

2’6” (762) 8-7/32” (208.8) 6’8” (2032) 8-1/2” (215.9)

2’8” (812.8) 9-7/32” (234.2)

2’10” (863.6) 10-7/32” (259.6)

3’0” (914.4) 11-7/32” (285) 7’0” (2133.6) 9-53/64” (250)

3’4” (1016) 13-7/32” (335.8)

3’6” (1066.8) 14-7/32” (361.2)

3’8” (1117.6) 15-7/32” (386.6) 7’2” (2184.4) 10-1/2” (266.7)

3’10” (1168.4) 16-7/32” (412)

4’0” (1219.2) 17-7/32” (437.4)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

FINISHED FLOOR

SEE MUNTIN BAR

44-3/8” (1127.1) 44-3/8” (1127.1)

Type 9 & 10 Window Moulding

Page 155: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

148Glass Sizes (Visible) and Lite Locations FG, FGLDoor Technical Data

February, 2009

L6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

FG

EQUAL EQUAL

7-7/8” (200)

VARIES

FGL

12-1/4”(311.2)

12”(304.8)FINISHED FLOOR LL

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 11-5/16” (287.3)

2’4” (711.2) 15-5/16” (388.9)

2’6” (762) 17-5/16” (439.7) 6’8” (2032) 59-3/8” (1508.1)

2’8” (812.8) 19-5/16” (490.5)

2’10” (863.6) 21-5/16” (541.3)

3’0” (914.4) 23-5/16” (592.1) 7’0” (2133.6) 63-3/8” (1609.7)

3’4” (1016) 27-5/16” (693.7)

3’6” (1066.8) 29-5/16” (744.5)

3’8” (1117.6) 31-5/16” (795.3) 7’2” (2184.4) 65-3/8” (1660.5)

3’10” (1168.4) 33-5/16” (846.1)

4’0” (1219.2) 35-5/16” (896.9)

DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT

2’0” (609.6) 12” (304.8)

2’4” (711.2) 16” (406.4)

2’6” (762) 18” (457.2) 6’8” (2032) 60” (1524)

2’8” (812.8) 20” (508)

2’10” (863.6) 22” (558.8)

3’0” (914.4) 24” (609.6) 7’0” (2133.6) 64” (1625.6)

3’4” (1016) 28” (711.6)

3’6” (1066.8) 30” (762)

3’8” (1117.6) 32” (812.8) 7’2” (2184.4) 66” (1676.4)

3’10” (1168.4) 34” (863.6)

4’0” (1219.2) 36” (914.4)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. OVER 8’0” (2438.4) A MAXIMUM 44” (1117.6) VISIBLE HEIGHT IS AVAILABLE ON HG TYPE DOORS. OVER 44” (1117.6) VISIBLE HEIGHT IS CONSIDERED A FG DOOR. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

Type 9 & 10 Window Moulding

Page 156: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

149Glass Sizes (Visible) and Lite Locations FG2, FG3, FG4

Door Technical DataFebruary, 2009

L6-1/4”(158.8)

8-1/4” (209.6)

FG2

6-1/4”(158.8)

VARIES (EQUAL)

6” (147)

VARIES (EQUAL)

12-1/4”(311.2)

6-1/4”(158.8)

8-1/4” (209.6)

FG3

6-1/4”(158.8)

VARIES (EQUAL)

6” (147)

VARIES (EQUAL)

12-1/4”(311.2)

VARIES (EQUAL)

6” (147)

6-1/4”(158.8)

8-1/4” (209.6)

6-1/4”(158.8)

VARIES (EQUAL)

6” (147)

12-1/4”(311.2)

6” (147)

VARIES (EQUAL)

VARIES (EQUAL)

VARIES (EQUAL)

6” (147)

FG4

FINISHED FLOOR

DOOR VISIBLE DOOR VISIBLE DOOR VISIBLE DOOR VISIBLE WIDTH WIDTH HEIGHT HEIGHT HEIGHT HEIGHT HEIGHT HEIGHT

2’0” (609.6) 11-5/16” (287.3)

2’4” (711.2) 15-5/16” (388.9)

2’6” (762) 17-5/16” (439.7) 6’8” (2032) 26-11/16” 6’8” (2032) 15-13/16” 6’8” (2032) 10-3/8” (653.8) (401.6) (263.5)

2’8” (812.8) 19-5/16” (490.5)

2’10” (863.6) 21-5/16” (541.3)

3’0” (914.4) 23-5/16” (592.1) 7’0” (2133.6) 28-11/16” 7’0” (2133.6) 17-1/8” 7’0” (2133.6) 11-3/8” (702.8) (435) (288.9)

3’4” (1016) 27-5/16” (693.7)

3’6” (1066.8) 29-5/16” (744.5)

3’8” (1117.6) 31-5/16” (795.3) 7’2” (2184.4) 29-11/16” 7’2” (2184.4) 15-13/16” 7’2” (2184.4) 11-7/8” (727.3) (401.6) (301.6)

3’10” (1168.4) 33-5/16” (846.1)

4’0” (1219.2) 35-5/16” (896.9)

NOTE: FOR DOORS OVER 7’2” (2184.4) UP TO AND INCLUDING 8’0” (2438.4) STILE AND RAIL DIMENSIONS SHOWN ARE MAINTAINED. ALWAYS INDICATE LOCATION OF LIGHT ON DOOR FACE WHEN ORDERING DOORS OVER 8’0” (2438.4).

FG2 FG3 FG4

* * *

* NOTE: A MINIMUM 6” STILE AND 6” RAIL IS REQUIRED FOR FIRE LABEL LISTED DOOR)

Type 9 & 10 Window Moulding

Page 157: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

150Face Type Location FVL, FNVLDoor Technical Data

May, 2012

L

12”(304.8)

FINISHED FLOOR

EQUAL EQUAL

VARIES

VARIES

12”(304.8)

VARIES

8-1/4” (209.6)

VARIES

VARIES

12”(304.8)

12”(304.8)

FVL FV = FULL VISION STANDARDS L = LOUVER STANDARDS

FNVL FNV = FULL NARROW VISION STANDARDS L = LOUVER STANDARDS

EXAMPLE: 12” X 12” (305 X 305) FULL VISION LITE

18” X 12” (457 X 305) LOUVER

EXAMPLE:6” X 36” (152 X 914) NARROW VISION LITE

18” X 12” (457 X 305) LOUVER

FV1L2 FNV1L2

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

Type 9 & 10 Window Moulding

CL

65”(1651)

6-1/4”(158.75)

Page 158: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

151Face Type Locations HGL

Door Technical DataFebruary, 2009

L6-1/4”(158.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

12”(304.8)

VARIES12”(304.8)

HGL HG = HALF GLASS STANDARDS L = LOUVER STANDARDS

FINISHED FLOOR

EXAMPLE: WINDOW PANE-HALF GLASS

18” X 12” (457 X 305) LOUVER

HG L2

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

Type 9 & 10 Window Moulding

Page 159: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

152Glass Sizes (Visible) and Lite Locations F2NV, 3FNVDoor Technical Data

February, 2010

L6-1/4”(158.8)

FINISHED FLOOR

8-1/4” (209.6)

16” (406.4)

16” (406.4)

6” (152.4)

6”(152.4)

F2NV

6-1/4”(158.8)

8-1/4” (209.6)

16” (406.4)

3FNV

EQUAL

6”(152.4)

6”(152.4)

6”(152.4)

6”(152.4)

6”(152.4)

42”(1066.8)

FD

EQUAL

VARIES

FDFV

EQUAL

VARIES

42”(1066.8)

L L

DOOR WIDTH FOR 3FNV MUST BE AT LEAST 3’7” (1092.2) WIDE!

Face Type Locations FD, FDFV

FDFV 10” (254) X 10” (254)FDFV1 12” (304.8) X 12” (304.8)

*NOTE: MINIMUM 6” STILES TO BE FIRE LABEL LISTED.

Type 9 & 10 Window Moulding

CL

65”(1651)

Page 160: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

153Face Type Locations FDFNV, FDHG

Door Technical DataFebruary, 2009

L

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

FINISHED FLOOR

VARIES

42”(1066.8)

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

42”(1066.8)

6-1/4”(158.8)

6-3/16” (157.2)

FDFNV FD = FLUSH DUTCH FNV = FULL NARROW VISION STANDARDS

FDHG FD = FLUSH DUTCH HG = HALF GLASS STANDARDS

EXAMPLE: FLUSH DUTCH

6” X 36” (152 X 914) NARROW VISION LITE

EXAMPLE:FLUSH DUTCH

(3) WINDOW PANE-HALF GLASS

FDFNV1 FDHG

Type 9 & 10 Window Moulding

Page 161: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

154Face Type Locations FDHGL, FDFNVLDoor Technical Data

February, 2009

L

FINISHED FLOOR

FDHGL FD = FLUSH DUTCH HG = HALF GLASS STANDARDS L = LOUVER STANDARDS

FDFNVL FD = FLUSH DUTCH FNV = FULL NARROW VISION STANDARDS L = LOUVER STANDARDS

EXAMPLE: FLUSH DUTCH

(3) WINDOW PANE-HALF GLASS18” X 12” (457 X 305) LOUVER

EXAMPLE:FLUSH DUTCH

6” X 36” (152 X 914) NARROW VISION LITE18” X 12” (457 X 305) LOUVER

FDHG3L2

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

42”(1066.8)

6-1/4”(158.8)

6-3/16” (157.2)

12”(304.8)

12”(304.8)

VARIES

6-1/4”(158.8)

8-1/4” (209.6)

VARIES

42”(1066.8) 12”

(304.8)

12”(304.8)

VARIES

VARIES

FDFNV1L2

PROVIDE CUTOUT ONLY SIZE FOR LOUVERS

Type 9 & 10 Window Moulding

Page 162: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

9/16” (13.7)

1/2” (12.3)

7/16” (11.1)

155Window Kit Cutout on Door

Door Technical DataMarch, 2016

L

1-1/2”(38.1)

1-3/4”DOOR

WINDOW KIT

NOTE:GLASS SIZE IS .875 LARGER THAN VISIBLE.DOOR CUTOUT IS 2.125”LARGER THAN VISIBLE.

GLASS SIZE

CUT-OUT

KIT BEYOND CUT-OUT

VISIBLE GLASS(ORDER SIZE)

7/16”(11.1)

1-1/16”(27.0)

7/16”(11.1)

Type 9 & 10 Kits

Type 9 & 10 Window Moulding

Page 163: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

156Face Type Locations FMS, HGMSDoor Technical Data

February, 2009

L

FINISHED FLOOR

EQUAL EQUAL

PER TEMPLATE

30”(762)

6-1/4”(158.8)

6-1/4”(158.8)

VARIES

EQUAL EQUAL

PER TEMPLATE

30”(762)

FMS FMS = FLUSH MAIL SLOT

HGMS HG = HALF GLASS STANDARDS MS = MAIL SLOT

EXAMPLE: (3) WINDOW PANE-HALF GLASS

MAIL SLOT

HG3MS

8-1/4” (209.6)

Type 9 & 10 Window Moulding

Page 164: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

157Face Type Locations FVMS, FNVMS

Door Technical DataFebruary, 2010

L

VARIES

FINISHED FLOOR

EQUAL

EQUAL

PER TEMPLATE

30”(762)

6-1/4”(158.8)

VARIES

EQUAL EQUAL

PER TEMPLATE

30”(762)

FVMS FV = FULL VISION STANDARDS MS = MAIL SLOT

FNVMS FNV = FULL NARROW VISION STANDARDS MS = MAIL SLOT

EXAMPLE: 6” X 36” (152 X 914) NARROW VISION LITE

MAIL SLOT

FNV1MS

EQUAL

VARIES

VARIES

EQUAL

8-1/4” (209.6)

FVMS 10” (254) X 10” (254)FV1MS 12” (304.8) X 12” (304.8)

Type 9 & 10 Window Moulding

CL

65”(1651)

Page 165: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

158Muntin Bar - Muntin Bar JointsDoor Technical Data

February, 2009

L

VERTICAL MUNTIN FOR1/4” (6.4) GLASS ONLY!

5/16” (7.9) INSIDE

11/32”(8.7)

HORIZONTAL MUNTIN FOR1/4” (6.4) GLASS ONLY!

NOTCH VERTICAL MUNTIN 3/16” (4.8) TO FIT INSIDE HORIZONTAL MUNTIN

MULTIPLE GLASS SIZES MAY VARYSLIGHTLY DUE TO MUNTINPOCKET DEPTH

3/16”(4.8)

9/16” (14.3)OUTSIDE

7/32”(5.6)

29/32”(23)

3/8”(9.5)

3/8”(9.5)

AVAILABLE WITH TYPE 1, 3, AND 9 WITH 3/8” POCKET ONLYMUNTIN BAR PART NUMBER: CD002402

VISION LITE FRAME

HORIZONTAL MUNTIN

NOTCH HORIZONTAL MUNTIN 3/8” (9.5) TO FIT INSIDE WINDOW KIT FRAME

5-1/8” (130.2) MINIMUMBETWEEN VISIBLEGLASS AREAS.(INCLUDES MOULDING)

VISIBLE GLASS

Page 166: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

159Cut Away View FG Moulding

Door Technical DataJune, 2009

L

HINGE OR LOCK CHANNEL

20 GAUGE (.91) STANDARDCHANNEL REINFORCING STANDARD

OUTSIDE SKIN

INVERTED TOP ORBOTTOM CHANNEL

20 GA. (.91) GALV. STEELGLASS MOULDING

#8 X 1-1/2”OHSMS

1-1/2” (38.1)

Type 9 & 10 Window Moulding

Page 167: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

160Door Vision Lite Kit (Standard)Door Technical Data

February, 2009

L

VISIBLE GLASS AREA

VISIBLE GLASS AREA

NOTE: ON FIRE LABEL DOORS USE A 6” (152.4) MINIMUM STILE BETWEEN VISIBLE GLASS AREAS AND BETWEEN VISIBLE GLASS AND EDGES OF DOOR.

5-1/8” (126) MINIMUM BETWEEN VISIBLE GLASS AREAS. (INCLUDES MOULDING)

TYPE 9 - POCKET SIZE: 3/8” (9.2)TYPE 10 - POCKET SIZE: 9/16” (13.7) 13/16” (19.9) 1-1/16” (26)

9/16”(13.7)

1-1/2”(38.1)

1-3/4”(42.9)

#8 SCREW

GLASS

INSIDE OUTSIDE

U.L. CLIP

Type 9 & 10 Window Moulding

Page 168: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

161777 Trio Door Construction

Door Technical DataAugust, 2016

16 GA. (1.4)BOTTOM END CHANNEL

22 GA. (.75) RIBS STANDARDWELDED EVERY 5” ALONG THE LENGTH TO A

22 GA. (.75) CORE PLATE. CORE IS CHEMICALLY BONDED TO ALL INTERIOR SURFACES

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL

(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

LOCK PREPARATIONAS REQUIRED

18 GA. (1.2), 16 GA. (1.4)OR 14 GA. (1.9) FACE SKINS

1-3/4” VERTICALLY STEEL STIFFENED FIBERGLASS CORE DOOR

BEVELED LOCK EDGE, HANDEDMAXIMUM GLASS THICKNESS - 1"

MAXIMUM FIRE LABEL - 180 MINUTEMAXIMUM SIZE 4’0” X 8’0” SINGLEMAXIMUM SIZE 8’0” X 8’0” PAIRED*MAXIMUM SIZE 8’0” X 9’0” PAIRED - 90 MINUTE*

*NO ASTRAGAL REQUIRED

L

Page 169: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

162707 Door Honeycomb Core ConstructionDoor Technical Data

September, 2014

L

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

HONEYCOMB CORE

14 GA. (1.9)LOCK CHANNEL

LOCK PREPARATIONAS REQUIRED

16 GA. (1.4)BOTTOM END CHANNEL

20 GA. (0.9) - 14 GA. (1.9)FACE SKINS

BONDED TO CORE

14 GA. (1.9) STANDARDHINGE CHANNEL

12 GA. (2.6) SPECIAL ORDER

AVAILABLE IN 1-3/4” THICKNESS ONLY

Page 170: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

163Non-Rated Door Louver

Door Technical DataMay, 2010

L

18 GA. (1.1) CR FRAME

20 GA. (.08) CR INVERTED “Y” BLADES

WELDED CORNER CONSTRUCTION

THE CURRIES NON-RATED LOUVER FOR 1-3/4” DOORS PROVIDES 50% FREE AIR FLOW WHILE FASTENING TO ONE SIDE TO ENSURE SECURITY.

Page 171: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

164777 Trio-E Door ConstructionDoor Technical Data

January, 2020

16 GA. (1.4)BOTTOM END CHANNEL

* THE U AND R VALUES WERE OBTAINED BY TESTING TO NFRC 102-2014 IN A CURRIES MERCURY THERMAL BROKEN FRAME.

22 GA. (.75) RIBS STANDARDWELDED EVERY 5” ALONG THE LENGTH TO A

22 GA. (.75) CORE PLATE. CORE IS CHEMICALLY BONDED TO ALL INTERIOR SURFACES

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL

(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

FOAM IN PLACE POLYURE-THANE

LOCK PREPARATIONAS REQUIRED

18 GA. (1.2) OR 16 GA. (1.4)

1-3/4” VERTICALLY STEEL STIFFENEDPOLYURETHANE CORE DOOR

BEVELED LOCK EDGE, HANDED1-3/4” VERTICALLY STEEL STIFFENED

FIBERGLASS CORE DOORBEVELED LOCK EDGE, HANDED

MAXIMUM GLASS THICKNESS - 1"MAXIMUM FIRE LABEL - 3 HOURS FOR ULMAXIMUM SIZE SINGLES - 4’0” X 8’0”MAXIMUM SIZE PAIRS - 8’0” X 8’0”

MAXIMUM FIRE LABEL - 90 MIN. WHMAXIMUM SIZE SINGLES - 4’0” X 8’0”PAIRS NOT AVAILABLE IN WH

POLYURETHANE DOOR ASSEMBLY THERMAL CHARACTERISTIC:U FACTOR - 0.36 (NFRC 102-2014)*R FACTOR - 2.78 (NFRC 102-2014)*

L

Page 172: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

16 GA. (1.4)BOTTOM END CHANNEL

* THE U AND R VALUES WERE OBTAINED BY TESTINGTO NFRC 102-2014 IN A CURRIES MERCURY THERMALBROKEN FRAME.

NOMINAL 18 GAUGE VERTICAL REINFORCEMENTS ARE PLACED 6” APART AND WELDED IN PLACE.

THE POLYURETHANE CORE FILLS THE ENTIRE DOOR CAVITY AND IS CHEMICALLY BONDED TO

ALL INTERIOR SURFACES.

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL

(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

FOAM IN PLACE POLYURETHANE

LOCK PREPARATIONAS REQUIRED

18 GA. (1.2), 16 GA. (1.4), OR 14 GA.(1.9)

1-3/4” VERTICALLY STEEL REINFORCEDPOLYURETHANE CORE DOOR

BEVELED LOCK EDGE, HANDED

MAXIMUM FIRE LABEL - 3 HOURS FOR ULMAXIMUM SIZE SINGLES - 4’0” X 7’0”MAXIMUM SIZE PAIRS - 6’0” X 7’0”

MAXIMUM SIZE SINGLES - 4’0” X 9’0”MAXIMUM SIZE PAIRS - 8’0’ X 9’0”

POLYURETHANE DOOR ASSEMBLY THERMAL CHARACTERISTIC:U FACTOR - 0.374 (NFRC 102 -2014)*R FACTOR - 2.70 (NFRC 102 -2014)*

165797 Mercury Energy Efficient Door Construction

Door Technical DataAugust, 2016

Page 173: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

166Factory Installed GlassDoor Technical Data

June, 2016

LKERALITE® FILMED GLASS (FIG03) and (FIG03E)GLASS DESCRIPTION

CERAMIC, FILMED FIRE AND SAFETY RATED GLASS BRAND NAME: KERALITE GRADE: STANDARD THICKNESS: 3/16” NOMINAL WARRANTY: 3 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE, EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201

FIRE LISTINGS

UL AND INTERTEK/WAR-NOCK-HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 715.4.6 AND 2406.

RATING MAXIMUM EXPOSED AREA MAXIMUM WIDTH MAXIMUM

HEIGHT DOOR SERIES

20, 45, 60,AND 90

2736 SQ IN 36” 76”707, 747, 777

847, 857

45, 60, AND 90 TR*

100 SQ INPER LEAF

12” 33” 727, 747-TR*

180100 SQ INPER LEAF

12” 33”707, 727, 747, 747-TR*,

777, 847, 857

*TEMPERATURE RISE

KERALITE® LAMINATED GLASS (FIG04) and (FIG04E)GLASS DESCRIPTION

CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS BRAND NAME: KERALITE GRADE: STANDARD THICKNESS: 5/16” NOMINAL WARRANTY: 5 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE, EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201

FIRE LISTINGS

UL AND INTERTEK/WAR-NOCK-HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 715.4.6 AND 2406.

RATING MAXIMUM EXPOSED AREA MAXIMUM WIDTH MAXIMUM

HEIGHT DOOR SERIES

20, 45, 60,AND 90

2736 SQ IN 36” 75”707, 747, 777

847, 857

45, 60, AND 90 TR*

100 SQ INPER LEAF

12” 33” 727, 747-TR*

180100 SQ INPER LEAF

12” 33”707, 727, 747, 747-TR*,

777, 847, 857

*TEMPERATURE RISE

Page 174: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

167Factory Installed Glass

Door Technical DataSeptember, 2013

LFIRELITE® NT GLASS (FIG05) and (FIG05E)GLASS DESCRIPTION

CERAMIC, FILMED FIRE AND SAFETY RATED GLASS BRAND NAME: FIRELITE NT GRADE: PREMIUM THICKNESS: 3/16” NOMINAL WARRANTY: 3 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE, EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201, AND ANSI Z97.1

FIRE LISTINGS

UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 715.4.6 AND 2406.

RATING MAXIMUM EXPOSED AREA MAXIMUM WIDTH MAXIMUM

HEIGHT DOOR SERIES

20, 45, AND 60 3204 SQ IN 36” 89”707, 747, 777

847, 857

90 2034 SQ IN 36” 56.5”707, 747, 777

847, 857

45, 60, AND 90 TR*

100 SQ INPER LEAF

12” 33” 727, 747-TR*

180100 SQ INPER LEAF

12” 33”707, 727, 747, 747-TR*,

777, 847, 857

*TEMPERATURE RISE

FIRELITE® PLUS GLASS (FIG06) and (FIG06E)GLASS DESCRIPTION

CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS BRAND NAME: FIRELITE PLUS GRADE: PREMIUM THICKNESS: 5/16” NOMINAL WARRANTY: 5 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE, EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201, AND ANSI Z97.1

FIRE LISTINGS

UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 715.4.6 AND 2406.

RATING MAXIMUM EXPOSED AREA MAXIMUM WIDTH MAXIMUM

HEIGHT DOOR SERIES

20 AND 45 3204 SQ IN 36” 89”707, 747, 847, 857

90 2034 SQ IN 36” 56.5”707, 747, 847, 857

45, 60, AND 90 TR*

100 SQ INPER LEAF

12” 33” 727, 747-TR*

180100 SQ INPER LEAF

12” 33”707, 727, 747,

747-TR*, 777, 847, 857

*TEMPERATURE RISE

Page 175: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

168Factory Installed GlassDoor Technical Data

September, 2013

L1/4” TEMPERED GLASS (FIG01) and (FIG01E)GLASS DESCRIPTION

1/4” CLEAR TEMPERED GLASS QUALITY RATING: Q3, ASTM C1036-06 THICKNESS: 1/4” NOMINAL WARRANTY: 1 YEAR LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201

GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 2406CANNOT BE USED ON FIRE RATED DOORS

1/4” FILMED WIRE GLASS (FIG02) and (FIG02E)GLASS DESCRIPTION

1/4” FILM WIRE, FIRE AND IMPACT SAFETY RATED GLASS QUALITY RATING: Q6, ASTM C1036-06 THICKNESS: 1/4” NOMINAL WIRE PATTERN: MISCO (DIAMOND PATTERN), BAROQUE (SQUARE PATTERN) WARRANTY: 1 YEAR LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE OR PEMKO FG 300090 OR 300045 AS REQUIRED, EXTERIOR DOORS WILL HAVE DUO-SIL FOR CAP BEAD IMPACT SAFETY RATING: CAT 1, CAT II, CPSC 16CFR1201, AND ANSI Z97.1

FIRE LISTINGS

UL AND INTERTEK/WAR-NOCK-HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 715.4.6 AND 2406.

RATING MAXIMUM EXPOSED AREA MAXIMUM WIDTH MAXIMUM

HEIGHT DOOR SERIES

PVC CLOSED CELL FOAM TAPE

20, AND 45 1296 SQ IN 36” 54”707, 747, 777

847, 857

45 TR* 100 SQ IN 12” 33” 727, 747-TR*

60 100 SQ IN 12” 33”707, 727, 747

747-TR*, 777, 847, 857

90 100 SQ IN 12” 33”707, 727, 747,

747-TR*, 777, 847, 857

PEMKO FG 300045

20, AND 45 1296 SQ IN 34” 84”707, 747, 777

847, 857

PEMKO FG 300090

60 552 SQ IN 12” 46”707, 747, 777

847, 857

90 552 SQ IN 12” 46”707, 747, 777

847, 857

*TEMPERATURE RISE

L

Page 176: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

169Factory Installed Glass

Door Technical DataMarch, 2015

INSULATED GLASS

GLASS DESCRIPTION

5/8” OVERALL INSULATING. LoE2 TEMPERED, ARGON FILLED THICKNESS: 5/8” NOMINAL WARRANTY: 10 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE AND DUO-SIL CAP SEAL ON BOTH SIDES AS NEEDED IMPACT SAFETY RATING: CAT II, CPSC 16CFR1201 GLASS IS MARKED IN: CAT II, CPSC 16CFR1201 AND 2406

CANNOT BE USED ON FIRE RATED DOORS

INSULATING PERFORMANCE

CENTER OF GLASS U FACTOR: .25 BTU/hr•FT2˚F SHADING COEFFICIENT (SC): .42 SOLAR HEAT GAIN (SHGC): .37 UV TRANSMITTANCE: 14%

5/8” INSULATED GLASS (FIG07E)

GLASS DESCRIPTION

1” OVERALL INSULATING. LoE2 TEMPERED, ARGON FILLED THICKNESS: 1” NOMINAL WARRANTY: 10 YEARS LIMITED INCLUDES: PVC CLOSED CELL FOAM GLAZING TAPE AND DUO-SIL CAP SEAL ON BOTH SIDES AS NEEDED IMPACT SAFETY RATING: CAT II, CPSC 16CFR1201 GLASS IS MARKED IN: CAT II, CPSC 16CFR1201 AND 2406

CANNOT BE USED ON FIRE RATED DOORS

INSULATING PERFORMANCE

CENTER OF GLASS U FACTOR: .25 BTU/hr•FT2˚F SHADING COEFFICIENT (SC): .41 SOLAR HEAT GAIN (SHGC): .36 UV TRANSMITTANCE: 13%

1” INSULATED GLASS (FIG08E)

L

Page 177: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

170747 Door Construction - Temperature Rise 450˚FDoor Technical Data

March, 2015

L 12 GA. (2.6)HINGE CHANNEL

16 GA. (1.4)BOTTOM END CHANNEL

22 GA. (.75) RIBS REQUIRED

14 GA. (1.9)CLOSER REINFORCEMENT CHANNEL(OPTIONAL)

16 GA. (1.4)TOP END CHANNEL

8 LB. DENSITY MINERAL WOOL

14 GA. (1.9)LOCK CHANNEL

LOCK PREPARATIONAS REQUIRED

18 GA. (1.2) OR 16 GA. (1.4) FACE SKINS SPOT WELDED TO RIBS

AT 6” (152) MAX. SPACING

RIBS WELDED TOGETHER AT ENDS6” (152) MAXIMUM SPACING

450˚F TEMPERATURE RISE RATING ONLY

Page 178: January, 20.pdf · GLASS KITS: Flush doors only. ASTRAGALS: Not available factory installed - field installation only. Hinge and lock locations are SDI manufacturers standard locations

FIRE DOOR LIMITATIONS

MAXIMUM RATING: 45 MINUTES (WARNOCK HERSEY)MAXIMUM SIZE: 4’0” X 7’2” (ENTRANCE DOOR)CORE TYPE: STEEL STIFFENED ONLYDOOR FACE GAUGE: 16 OR 14VISION LITE: MAXIMUM 216 SQ IN. TYPE 11 KITFRAME REQUIREMENTS: MINIMUM 16 GAUGE, KD OR WELDED, MASONRY OR DRYWALL (COMPRESSION ANCHORS NOT ALLOWED)

171Behavioral Healthcare Patient Room Access Opening

Door Technical DataNovember, 2019

L

POLYSTYRENE CONSTRUCTION STANDARD.STEEL STIFFENED AND HONEYCOMB CONSTRUCTION OPTIONAL.

16 GA. DOOR FACE STANDARD14 GA. DOOR FACE OPTIONAL

STEP THROUGH DOOR

ACCEPTED BY THE NEW YORK STATE OFFICE OF MENTAL HEALTH

TOP CAP REQUIRED(SCREW APPLIED AND FILLED)

CONTINUOUS HINGE PEMKO CFMSLF-HD1(STANDARD) MARKAR FM300 (OPTIONAL)

6” MINIMUM STILE ON HINGE SIDE

ACCESS DOOR INSTALLED AT FACTORY WITH

ACCESS DOOR STANDARD SIZE 1’8” X 5’0” NOMINAL (CUSTOM SIZES AVAILABLE CONTACT FACTORY)

VISION LIGHT AVAILABLETYPE 11 KIT STANDARD, TYPE 4 OPTIONAL6” MINIMUM STILE AND RAIL ON ACCESS DOOR

ONE MORTISE DEAD BOLT PREPARATION, E3 STRIKE PREP @ 48” AFF STANDARD. SECOND DEADLOCK OPTIONAL.

FLUSH CUP PULL PREPARATION @ 40” AFF

ALL EDGES EASED

CORRIDOR SIDE

LOCK PREPARATION AS REQUIREDFRAME STRIKE PREP @ 40" AFF

STRIKE PREPARATION (E3) @ 48" AFF

3’0” MINIMUM WIDTH6’8” MINIMUM HEIGHT

14 GA. ONE PIECE FLAT ASTRAGAL APPLIED AROUND ACCESS DOOR OPENING ON PATIENT ROOM SIDE OF DOOR

TOP CAP OPTIONAL

8” MINIMUM STANDARDSTILE ON LOCK SIDE

FLUSH EDGE SEAM WELDED AND FILLED - TYPE “T”

10” MINIMUM TOP RAIL

10” MINIMUM STANDARD BOTTOM RAIL