j1939 powercell and configuration guide hmi … powercell setup and configuration guide hmi systems...
TRANSCRIPT
![Page 1: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/1.jpg)
Version20141021 P a g e |1Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
J1939POWERCELLSetupandConfigurationGuideHMISystems482CRMSwitches
TableofContentsOverview .......................................................................................................................................... 2
Warnings.......................................................................................................................................... 3
J1939 POWERCELL Technical Details ............................................................................................... 4
POWERCELL Installation Steps ........................................................................................................ 5
Mounting the POWERCELL .......................................................................................................... 5
Supplying 12‐volt Power .............................................................................................................. 5
Wiring the Output Harnesses ...................................................................................................... 6
Installing Fuses ............................................................................................................................ 8
Connecting J1939 CAN Network .................................................................................................. 8
Configuring J1939 Commands from HMI Systems 482CRM ........................................................... 9
Load CANconnect Software ......................................................................................................... 9
Install Software for CAN to J1939 Adaptor ................................................................................. 9
Setting the J1939 POWERCELL Address .................................................................................... 10
CAN Parameter Setup ................................................................................................................ 11
POWERCELL Personality Glossary .............................................................................................. 14
Track...................................................................................................................................................14 Toggle.................................................................................................................................................14 PulseWidthModulation(PWM).............................................................................................14 Post‐Time..........................................................................................................................................14 ToggleTime.....................................................................................................................................15 Track:Pattern.................................................................................................................................15
Powering the System ..................................................................................................................... 16
Warranty Information ................................................................................................................... 17
![Page 2: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/2.jpg)
Version20141021 P a g e |2Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Overview
TheInfinityboxJ1939POWERCELLbringsflexiblemultiplexedpowerdistributiontoanyvehiclebuilder.UsingstandardJ1939PGNstructuresandcommands,youcancontroltheoutputsonthePOWERCELLwithpracticallyanyJ1939inputdevice.
TheJ1939POWERCELLcomeswithastandardconfigurationthatallowstheend‐userbroadflexibilityincreatingtheirownlayoutstosuittheiruniqueapplications.UsingsimplesoftwaretoolsfromtheirJ1939inputmanufacturer,theycanquicklyconfigurethesysteminthefield.Incaseswherecustomconfigurationsarerequiredforaspecificvehicle,thesystemcanbemodifiedeasily.Contacttechnicalsupportformoredetails.
![Page 3: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/3.jpg)
Version20141021 P a g e |3Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
WarningsTHEINFINITYBOXJ1939POWERCELLISAFUSEDPOWERDISTRIBUTIONMODULEFORVEHICLES.PROPERCAREMUSTBETAKENTOFUSETHEINPUTFEEDSTOTHECELLAND THE OUTPUT FEEDS FROM THE CELL. IMPROPER FUSE SELECTION CAN CAUSEDAMAGETOTHEVEHICLEELECTRICALSYSTEMRESULTINGINFIRE.PROPERCAREMUSTBETAKENTOENSURETHATPOWER IS CORRECTLYAPPLIED TOTHEPOWERCELL.REVERSINGPOLARITYTOTHEPOWERANDGROUNDFEEDSWILLCAUSEIRREPARABLEDAMAGETOTHECELLANDWILLVOIDTHEWARRANTY.ADDINGANYELECTRONICSMODULESTOAVEHICLEWILLINCREASETHEDEMANDONTHEBATTERY.CAREMUSTBETAKENTOMAINTAINACHARGEONTHEBATTERYWHENTHEVEHICLESITSIDLEFORPERIODSOFTIME.THISISESPECIALLYIMPORTANTWITHGEL‐CELL AND AGM BATTERIES. WE STRONGLY RECOMMEND INSTALLING A
DISCONNECTSWITCHTHATSEPARATESTHEELECTRICALLOADSINTHEVEHICLEFROM
THEBATTERYWHENNOTINUSE.
![Page 4: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/4.jpg)
Version20141021 P a g e |4Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
J1939POWERCELLTechnicalDetailsSystemOperatingVoltage:7.0to15.8VDCNumberofOutputs:10OutputType:High‐SideSwitchedviaMOSFETsMaximumCurrentRatingperOutput:25‐ampsMaximumCurrentRatingperPOWERCELL:125‐ampsInternalFusing:StandardMini™FuseMaximumOperatingTemperature:125°CMinimumOperatingTemperature:‐20°C
![Page 5: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/5.jpg)
Version20141021 P a g e |5Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
POWERCELLInstallationSteps
MountingthePOWERCELLMountthePOWERCELLonasuitableflatsurfaceinthevehicle.Usethe4mountingpointsinthecornersofthecelland1/4–inchhardware.TherecommendedmethodtomountthePOWERCELListouse¼‐inchX5/8‐inchshoulderscrews.Ifnotusingshoulderscrews,takecareastonotcrushthemountingpointsbyovertighteningthescrews.Inapplicationswherethesteady‐statecurrentdrawoutofthePOWERCELLexceeds90‐amps,mountthePOWERCELLinanareawithadequateventilationandwiththefinsoftheheatsinkrunningvertically.
Supplying12‐voltPowerThePOWERCELLgetsits12‐voltpowerfromthe3circularMaxi‐styleconnectorsontheedgeofthecell.Eachoftheseconnectorscanacceptupto60‐amps.Thefollowingtablesummarizesallofthecomponentsfortheseconnectors.ThePOWERCELLinputconnectorsusereadilyavailableconnectorcomponentsfromDelphi.SeetheinstructionsfromDelphiforproperassemblyandterminationoftheseconnectorcomponents.BasedonthetotalcurrentoutputofthePOWERCELLrequired,install1or2powerfeedsintotheroundMaxi‐styleconnectors.SealthethirdremainingconnectorwithanPOWERCELLsealingplug.Table1:POWERCELLInputConnectorComponents.
DelphiPartNumber
POWERCELL
Input
Connector
Connector 12129380Seal 12129382TPA 12129384WireSeal 12129381Terminal 12129414
EachofthepowerfeedwirestothePOWERCELLshouldbeprotectedwithafuselocatedascloselytothebatterysourceaspossible.SizethefusebasedonthegaugeofwirefeedingthePOWERCELL.TheTable2summarizestheproperfusesizesfordifferentwires.
![Page 6: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/6.jpg)
Version20141021 P a g e |6Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Table2:MaximumFuseRatingsforDifferentWireGauges.
AWGSize MaximumFuseRating(Amps)12 4010 508 60
WiringtheOutputHarnessesThePOWERCELLoutputconnectorsusereadilyavailableconnectorcomponentsfromDelphi.SeetheinstructionsfromDelphiforproperassemblyandterminationoftheseconnectorcomponents.Table3summarizesalloftheconnectorandterminalcomponentsrequiredtobuildcustomwiringharnessesforyourJ1939POWERCELL.Table3:POWERCELLOutputConnectorComponents.
DelphiPartNumber
POWERCELL
Output
Connector
Connector/Seal 12110295
TPA 12059195
WireSeal 12015323
Terminal 12129493
Eachoutputharnesshasonegroundwireand5outputwires.Thegroundwiresshouldbe14‐AWGandshouldbeconnectedtothevehicleground.ItisimportantthatthePOWERCELLisgroundedtothechassisthroughametal‐to‐metalconnection.Makesuretoremoveallpaint,powdercoating,dirtandgreasefromthecontactarea.Theindividualoutputwiresshouldbeproperlysizedtocarrytheoutputload.ThemaximumoutputcurrentforasinglePOWERCELLoutputis25‐amps.ThetotalPOWERCELLcancarryupto125‐amps.Exceedingthesevalueswilldamagethecellandvoidthewarranty.
![Page 7: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/7.jpg)
Version20141021 P a g e |7Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Table4summarizesthedetailsoftheoutputharnessesbyconnectorandcavityidentification.Table4:POWERCELLOutputHarnessConnectorDetails.CavityID ConnectorA ConnectorBA GROUND GROUNDB Output10 Output1C Output9 Output2D Output8 Output3E Output7 Output4F Output6 Output5Figure1identifiesalloftheconnectorsontheJ1939POWERCELL.
Figure1:SocketIdentificationforJ1939POWERCELL.
![Page 8: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/8.jpg)
Version20141021 P a g e |8Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
InstallingFusesThePOWERCELLhasinternalfuseholderstoprotecttheoutputwiresfromshortcircuitsandlow‐overloads.TheholdersaredesignedforastandardMini™automotivefuse.Selecttheratingoffusetoprotectthesmallestgaugeofwireintheharnessforeachoutput.Neveruseafuseratedathigherthan25‐ampstoprotectaPOWERCELLoutput.Table5givesrecommendationsonfuseratingsfordifferentwiregauges.Table5:MaximumFuseRatingsforDifferentWireGauges.
AWGSize MaximumFuseRating(Amps)20 1018 1516 2014 25
UseonlyOEMapprovedMini™fusestoprotectthePOWERCELLoutputs.Therearenumerousgrey‐marketmanufacturersoffusesthatareunsafeandunreliable.RecommendedmanufacturersforthesefusesareLittelfuse,Inc,BussmannandPacificEngineering.
ConnectingJ1939CANNetworkTheCANsocketsontheJ1939POWERCELLsconnecttheJ1939inputdevicetothecells.Thesesocketsprovide12‐voltpowerfortheJ1939inputdeviceandtheCANHI&LOWconnectionfortheJ1939network.TherearetwoCANsocketsonthePOWERCELLsothatmultipleJ1939POWERCELLsandJ1939inMOTIONCellscanbeconnectedonthesamenetwork.AnCANterminatorplugwitha120‐ohmresistorshouldbeinsertedintothelastopenCANsocketontheJ1939network.ThetwoCANsocketsonaPOWERCELLareelectricallyidenticalsoyoucanplugtheCANconnectorintoeithersocket.Table6showsthefunction,cavityidentificationandwirecolorsfortheCANconnector.ConnectthecorrespondingwiresfromtheJ1939inputdevicetothesecavitiesintheconnector.
![Page 9: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/9.jpg)
Version20141021 P a g e |9Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Table6:CANConnectorWiringDetails.
CavityID Function StandardWireColor5 Ground Black6 CANLOW Green7 CANHIGH Yellow8 +12VoltPower Red
WhenbuildingtheJ1939networkbetweenthecells,the+12VoltPowerwiresandtheGroundwiresshouldonlygobetweenthefirstPOWERCELLandtheJ1939inputdevice.ThereshouldnotbepowerandgroundwiresbetweenthedifferentJ1939cellsinthenetwork.TheJ1939POWERCELLcansupplyatotalof0.6‐ampsoutonthe+12VoltPowerwireintheconnectorsocket.IfthetotalcurrentdrawfortheJ1939inputdevicesexceedsthislimit,theymustbeconnectedto+12voltsfromadifferentsource.
ConfiguringJ1939CommandsfromHMISystems482CRM
LoadCANconnectSoftwareFollowtheinstructionssuppliedwiththeHMISystemsCANconnectSoftwareforproperinstallation.Moreinformationcanbefoundatwww.hmisystems.net.
InstallSoftwareforCANtoJ1939AdaptorFollowtheinstallationinstructionssuppliedwithyourJ1939toUSBadaptor.
![Page 10: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/10.jpg)
Version20141021 P a g e |10Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
SettingtheJ1939POWERCELLAddressEachJ1939POWERCELLorJ1939inMOTIONCellmusthaveitsownuniqueaddressforthenetworktoworkcorrectly.TheaddressissetbyarrangingjumpersinabinarypatternunderthecoverofthePOWERCELL.Figure2showsthelocationoftheaddressheadersonthePOWERCELL.
Figure2:LocationoftheAddressHeadersontheJ1939POWERCELL.
![Page 11: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/11.jpg)
Version20141021 P a g e |11Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Figure3showshowtoproperlyorientthejumpersontheheaderstosetthecelladdress.
Figure3:CorrectOrientationoftheAddressHeaders.
CANParameterSetupForPGN’sintherangeofFF00throughFF0F,thefirst60ofthe64bitsintheavailable8bytescorrespondtooutputsonthecellsattachedtotheJ1939network.A(1)inanyofthesebitswillcauseitscorrespondingcelloutputtoreactbasedonitsconfigurationtable.OnoneJ1939network,therecanbetwodifferentgroupsofJ1939inputdevicesassignedtoPGN’sFF00throughFF0F.J1939inputdevicesinGroup1canbeassignedPGN’sFF00throughFF07andcancontrolPOWERCELLorinMOTIONcellsaddressedatA1,A2orA3..J1939inputdevicesinGroup2canbeassignedPGN’sFF08throughFF0FandcancontrolPOWERCELLorinMOTIONcellsaddressedatA4,A5orA6.SwitchesassignedtoGroup1cannotcontrolcellsassignedinGroup2.SwitchesinGroup2cannotcontrolcellsassignedinGroup1.SeeFigure4formoredetails.
![Page 12: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/12.jpg)
Version20141021 P a g e |12Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Figure4:Groups,PGN’sandCellAddressesforJ1939Network.Table7summarizesthecontrolbits,theassignedpersonalitiesandthedetailsforeachoutputintheGroup1cells.Table7:ControlBitDetailsforGroup1Outputs.
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Cell Address 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 1 1
Cell Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2
Connector B B B B B A A A A A B B B B B A A A A A B B B B B A A A A A B B
Cavity ID B C D E F F E D C B B C D E F F E D C B B C D E F F E D C B B C
Personality
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Toggle
Toggle
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Cell Address 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 2 2 X X X X
Cell Output 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 6 7 8 9 10 9 10 X X X X
Connector B B B A A A A A B B B B B A A A A A B B B A A A A A A A X X X X
Cavity ID D E F F E D C B B C D E F F E D C B B C D E F F E D C B X X X X
Personality
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Track: PWM 50%
Track: PWM 50%
Track: PWM 50%
Post Time: 30 Sec.
Post Time: 60 Sec.
Toggle Time: 30 Sec.
Track: Pattern
Track: Pattern
Track: Pattern
Track: Pattern
X X X X
Byte 5 Byte 6 Byte 7 Byte 8
Byte 1 Byte 2 Byte 3 Byte 4
![Page 13: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/13.jpg)
Version20141021 P a g e |13Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
Table8summarizesthecontrolbits,theassignedpersonalitiesandthedetailsforeachoutputintheGroup2cells.Table8:ControlBitDetailsforGroup2Outputs.
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Cell Address 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 4 4
Cell Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2
Connector B B B B B A A A A A B B B B B A A A A A B B B B B A A A A A B B
Cavity ID B C D E F F E D C B B C D E F F E D C B B C D E F F E D C B B C
Personality
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Track
Toggle
Toggle
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Cell Address 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 5 5 X X X X
Cell Output 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 6 7 8 9 10 9 10 X X X X
Connector B B B A A A A A B B B B B A A A A A B B B A A A A A A A X X X X
Cavity ID D E F F E D C B B C D E F F E D C B B C D E F F E D C B X X X X
Personality
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Toggle
Track: PWM 50%
Track: PWM 50%
Track: PWM 50%
Post Time: 30 Sec.
Post Time: 60 Sec.
Toggle Time: 30 Sec.
Track: Pattern
Track: Pattern
Track: Pattern
Track: Pattern
X X X X
Byte 5 Byte 6 Byte 7 Byte 8
Byte 1 Byte 2 Byte 3 Byte 4
![Page 14: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/14.jpg)
Version20141021 P a g e |14Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
POWERCELLPersonalityGlossaryTheJ1939POWERCELLhasapre‐configuredlibraryofpersonalitiesthatdefinehowtheoutputreactswhenitreceivesaJ1939command.Thefollowinglistdescribesthesedifferentpersonalitiesandtheirbehaviors.
TrackTrackisthemostbasicpersonality.Theoutputtracksthestateoftheinput.WhentheJ1939switchispressedorlatchedintoanONposition,itisbroadcastinganONcommandtothePOWERCELLoutput.ThatoutputwillremainONaslongastheJ1939inputdeviceisbroadcastingtheONcommand.WhentheJ1939inputdevicebroadcastsanOFFcommand,thePOWERCELLoutputturnsOFF.
ToggleThetogglepersonalitylatchesthestateofthePOWERCELLoutputineitheranONorOFFstatebasedonreceivingacommandfromtheJ1939inputdevice.TheJ1939inputdevicebroadcastsacommandindicatingthatthestateoftheswitchhaschangedfromOFFtoONandbacktoOFFagain.ThisactioncausesthePOWERCELLtochangethestateoftheoutputfromOFFtoONorONtoOFF.ThisistobeusedwithJ1939inputsdevicesthathaveamomentarymechanicalactionandbroadcastachangeinswitchstateinthepressedpositionoftheswitch.
PulseWidthModulation(PWM)ThePoweroutputsarecontrolledbysolid‐stateMOSFETs.ThisallowsthePOWERCELLtovarytheamountofpowercomingoutofanoutputbypulsingtheoutputrapidly.Thisallowsforeasycontroloflightdimming,heatercontrolandmotorspeed.ThedefaultPWMdutycycleforaJ1939POWERCELLoutputis50%.ThebasefrequencyofthePWMpulseis200Hz.Customdutycyclesandbasefrequenciesareavailable.Contacttechnicalsupportformoreinformation.NOTE:PulseWidthModulationofinductiveloadswillrequireaquenchingdiodetosuppressanyback‐EMF.Consultthemanufacturerofyourloadformoreinformation.FailuretoinstallquenchingdiodeswillresultindamagetothePOWERCELLoutputandvoidthewarrantyofthecell.
Post‐Time
![Page 15: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/15.jpg)
Version20141021 P a g e |15Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
APostTimeoutputisaTrackoutputwithdelaybuiltintoit.TheoutputturnsONwiththeJ1939input.WhentheJ1939inputturnsOFF,thePOWERCELLoutputremainsONforapresetperiodoftime.Thestandardconfigurationhasoptionsfor30and60seconds.Customtimingisavailable.Contacttechnicalsupportformoreinformation.
ToggleTimeToggleTimesetsatimeronthePOWERCELLoutputbasedonamomentaryinputfromtheJ1939inputdevice.AmomentarypressoftheinputswitchwillcausethePOWERCELLoutputtoturnONforapresetperiodoftime.ThePOWERCELLoutputwillturnOFFafterthispresetperiodoftimeregardlessforhowlongtheJ1939inputswitchispressed.Thestandardtimervalueis30secondsfromthepressoftheJ1939inputswitch.Customtimingisavailable.Contacttechnicalsupportformoreinformation.
Track:PatternTrackPatternisatrackingpersonalitythatgeneratesapatternapproximatingavehicleturn‐signal.ThePOWERCELLoutputwillturnONandOFFatarateofapproximatelyonecycleper2seconds.Theduty‐cycleofthepatternisapproximately50%.Custompatternsareavailable.Contacttechnicalsupportformoreinformation.
![Page 16: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/16.jpg)
Version20141021 P a g e |16Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
PoweringtheSystemOncetheJ1939inputdevicesareproperlysetupandconfigured,connectthenetworkto+12voltsthroughtheinputharnessestothecells.After3seconds,thesystemwillbecommunicatingwiththeJ1939inputdevices.ThereisablueLEDlocatedtowardsthecenterofthePOWERCELLundertheclearcover.Thislightindicatesthestatusofthecommunicationonthenetwork.Whenthesystemisproperlyconnectedandcommunicating,thelightshouldblinkattherateestablishedontheHMIswitchpanel.ThelightwillalsoflashwhenitreceivesaswitchcommandfromoneoftheJ1939inputdevicesonthenetwork.IftheblueLEDturnsonandstaysonafterpowerisappliedtothesystem,checktheconnectorsintheJ1939networkorchecktomakesurethatthe120‐Ohmterminatorresistorisproperlyinstalledinthenetwork.AsteadybluelightindicatesthatthePOWERCELLprocessorisoperatingbutthereisnocommunicationontheJ1939network.IftheblueLEDdoesnotilluminateatall,checktomakesurethatyouaregettingpowertothePOWERCELL.
![Page 17: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview](https://reader031.vdocuments.us/reader031/viewer/2022022504/5ab7a3fe7f8b9a684c8bbcfd/html5/thumbnails/17.jpg)
Version20141021 P a g e |17Infinitybox,LLC|www.infinitybox.com|(847)232‐1991
WarrantyInformationInfinitybox,LLC(“Infinitybox”)warrantsagainstanydefectsinmaterialsandworkmanshiptotheProduct’smodules,wiringharnessesandaccessorymodulesforaperiodofone(1)yearfromthefirstdateofpurchase.Subjecttothetermsofthiswarrantydescribedbelow,InfinityboxwillreplaceanysuchdefectiveProductthatisreturnedtoInfinityboxwithintheone(1)yearperiodfrominitialpurchase.ReplacementofanydefectivepartorProductwillnotextendtheapplicablewarrantyperiod.Thewarrantydoesnotapplyto:(i)anyProductthatisnotinstalledincompliancewiththeapplicableProductdocumentation;(ii)anydefectin,orfailureof,theProductresultingfromanaccident,shock,negligence,waterimmersionormisuse;(iii)anyProductthathasbeenmodified,adjusted,repaired,ordisassembledbyanypartyotherthanInfinitybox;or(iv)anydefectotherthaninmaterialsandworkmanship.ThiswarrantycoversonlytheoriginalpurchaserofProductpurchasedfromanInfinityboxauthorizeddealerintheUnitedStates.Inordertoreceivewarrantyservice,purchasermustprovideInfinityboxwithacopyofthereceiptstatingthedealername,productpurchasedanddateofpurchase.Productsfoundtobedefectiveduringthewarrantyperiodwillbereplaced(withaproductdeemedtobeequivalentorbetter)atthediscretionofInfinitybox.Infinitybox’ssoleliabilityforanydefectiveProductislimitedsolelytothereplacementofProductpursuanttothiswarranty.Infinityboxreservestherighttoreplaceanyrepairablepartswithneworrefurbishedparts.INFINITYBOXDISCLAIMSALLOTHERWARRANTIES,WHETHEREXPRESS,IMPLIEDORSTATUTORY,SUCHASWARRANTIESOFMERCHANTABILITYANDFITNESSFORPURPOSE.INNOEVENTSHALLINFINITYBOXBELIABLEFORANYPUNITIVE,INDIRECT,INCIDENTALORCONSEQUENTIALDAMAGES,INCLUDINGWITHOUTLIMITATION,LIABILITYFORLOSSOFUSE,LOSSOFPROFITS,LOSSOFPRODUCTORBUSINESSINTERRUPTIONHOWEVERTHESAMEMAYBECAUSED,INCLUDINGNEGLIGENCE.