itzhak tserruya rich 2004, playa del carmen 1 rich 2004 playa del carmen, mexico nov. 30 – dec. 5,...
TRANSCRIPT
Itzhak TserruyaItzhak Tserruya RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen 11
RICH 2004RICH 2004Playa del Carmen, MexicoPlaya del Carmen, Mexico
Nov. 30 – Dec. 5, 2004Nov. 30 – Dec. 5, 2004
Itzhak TserruyaItzhak Tserruya
Short report from RICH 2004 at Short report from RICH 2004 at Playa del Carmen Playa del Carmen
Itzhak TserruyaItzhak Tserruya RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen 22
There are three experiments that have There are three experiments that have constructed or are constructing RICH constructed or are constructing RICH counters with CsI photocathodes:counters with CsI photocathodes:– COMPASS COMPASS – RICH detector for kaon Physics in Hall A at RICH detector for kaon Physics in Hall A at
Jefferson LabJefferson Lab– ALICE (STAR)ALICE (STAR)
RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen Silvia DALLA TORRE Silvia DALLA TORRE 33
Itzhak TserruyaItzhak TserruyaPlaya del Carmen, 30/11-5/12/2004 - 5Playa del Carmen, 30/11-5/12/2004 - 5thth RICH Workshop RICH Workshop 33
SM1 dipoleSM1 dipole
SM2 dipole
Polarised Target
HCAL1
Muon-filter1,MW1
Micromegas,DC,SciFi
Gems,SciFi,DCs,straws
MWPC Gems Scifi
trigger-hodoscopes
Silicon
COMPASS COMPASS SPECTROMETERSPECTROMETER
RICH_1
BMS
Gem_11
ECAL2,HCAL2
straws,MWPC,Gems,SciFi
straws Muon-
filter2,MW2
DW45
SciFi
Veto
Beam: 160 GeV µ+
2 . 108 µ/spill
(4.8 s/16.2s)
P ~ 80%
44 44
COMPASS RICH-1 - DESIGNCOMPASS RICH-1 - DESIGN
from the experiment design:from the experiment design:
hadron PID up to ~50 GeV/chadron PID up to ~50 GeV/c LARGE acceptance (large LARGE acceptance (large
size): size):
H: 500 mrad H: 500 mrad
V: 400 mrad V: 400 mrad
able to stand trigger rates able to stand trigger rates
up to 100 KHzup to 100 KHz beam rate up to 10beam rate up to 1088 Hz Hz minimize materialminimize material
+ detector designed in 1996+ detector designed in 1996
radiator:radiator:
CC44FF1010
5 m
5 m
6 m6 m3 m3 m
photon photon detectors:detectors:CsI MWPCCsI MWPC
mirrormirrorwallwall
vesselvessel
radiator:radiator:
CC44FF1010
detection of detection of VUVVUV photons photons(165-200 nm)(165-200 nm)
RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen Silvia DALLA TORRE Silvia DALLA TORRE 55
Itzhak TserruyaItzhak TserruyaPlaya del Carmen, 30/11-5/12/2004 - 5Playa del Carmen, 30/11-5/12/2004 - 5thth RICH Workshop RICH Workshop 55
PHOTON DETECTIONPHOTON DETECTIONphoton photon
detectorsdetectors (PD) : (PD) :
5.3 m5.3 m22 MWPCs MWPCs
(8 chambers)(8 chambers)
with with CsI CsI
photocathodephotocathode
read-out:read-out:
84,000 analog84,000 analog
read-out ch.sread-out ch.s
with extended with extended
local intelligencelocal intelligence
MWPCs with MWPCs with
CsI photocathodesCsI photocathodes
2 CsI 2 CsI photocathodes,photocathodes,60 x 60 cm60 x 60 cm2 2 eacheach
RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen Silvia DALLA TORRE Silvia DALLA TORRE 66
Itzhak TserruyaItzhak TserruyaPlaya del Carmen, 30/11-5/12/2004 - 5Playa del Carmen, 30/11-5/12/2004 - 5thth RICH Workshop RICH Workshop 66
photocathodephotocathodestoringstoring
glove box to glove box to handle handle photocathodesphotocathodes
photocathode photocathode transportation transportation systemsystem
MWPCs WITH LARGE SIZE MWPCs WITH LARGE SIZE PHOTOCATHODES, PHOTOCATHODES, COMPASS EXPERIENCECOMPASS EXPERIENCE
CsI: hygroscopicCsI: hygroscopic,,water degrades QEwater degrades QE never never exposed to airexposed to air(max 50 ppm O(max 50 ppm O2 ,2 ,
routinely: 10 ppm)routinely: 10 ppm)
marble tablemarble table with x,y with x,y movement and microscopemovement and microscopeto solde to solde anode wireanode wire and for and fordimensional checksdimensional checks (gaps, (gaps, planarity within 100 planarity within 100 m)m)
77 77
5th International Workshop on RICH Counters (RICH2004) Playa del Carmen, Mexico November 30 – Dececember 5, 2004
E.Cisbani, S.Colilli, F.Cusanno,S.Frullani, R.Fratoni, F.Garibaldi, F.Giuliani, M.Gricia,
M.Iodice, M.Lucentini, L.Pierangeli, F.Santavenere,
G.M.Urciuoli, P.Veneroni, G. De Cataldo, R. De Leo, L.Lagamba,
E.Nappi, J.LeRose, B.Kross, B.Reitz, J.Segal, C.Zone,
H.Breuer
INFN – JLAB – Univ. Of Maryland
JLAB Hall A RICH
COLLABORATION
8
Freon Radiator: 1800x400x15 mm3 single box with quartzwindows glued on neoceram housing
Grid plane: 100 m positive wires (collects electrons ionized in the gap)
Wire chamber : composed by 20 m anode wires plane sandwitched between a cathode plane formed by 100 m wires and the cathode plane formed by the photocathodes
Three Photocathodes :
403x640 mm2 each, divided in 8.4 x 8 mm2 size pads evaporated with a 300 nm CsI layer
JLAB Hall A RICH layout – similar to ALICE HMPID RICH
Mauro Iodice – RICH2004 - Playa del Carmen, Mexico - Nov.30 Dec. 5, 2004
9
Mauro Iodice – RICH2004 - Playa del Carmen, Mexico - Nov.30 Dec. 5, 2004
Photocathode positioning in the glove box
10
Mauro Iodice – RICH2004 - Playa del Carmen, Mexico - Nov.30 Dec. 5, 2004
JLAB Hall A RICH: the evaporation system
Photocathode
110 cm
120
cm
10-6 mbar vacuum2 nm/s CsI deposition at T = 60ºC (CERN experts indications). Vacuum - heating conditions starts 15 – 24 h before evaporation. A post-evaporation heat treatment is done for 12 hours.
crucibles
Quantum Efficiency
MeasurementSystem
details in : F.Cusanno et al.NIM A502(2003)251
Itzhak TserruyaItzhak Tserruya RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen 1111
ALICE HMPID ALICE HMPID • Covers ~5% of central barrel phase space• Extends identification of /K to 3 GeV/c and K/p to 5 GeV/c
Itzhak TserruyaItzhak Tserruya RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen 1212
ALICE HMPID ALICE HMPID Proximity focusing RICH counters Proximity focusing RICH counters
consisting of seven modules.consisting of seven modules.
15 mm thick liquid C15 mm thick liquid C66FF1414 radiator radiator
(n= 1.2988 at (n= 1.2988 at = 175 nm = 175 nm) 12 m12 m22 of CsI photocathode CsI photocathode deposited onto the pad cathode of deposited onto the pad cathode of a MWPC.a MWPC.
proximity gap
C6F14 radiator
CH4
MWPCCsI photo-cathode 4 mm
80 mm
10mm
5 mm
(see talk of A. Gallas)
( talk of H. Hoedlmoser)
Itzhak TserruyaItzhak Tserruya 1313
The CsI evaporation station at CERN The CsI evaporation station at CERN
Itzhak TserruyaItzhak Tserruya 1414
ALICE HMPID prototype in STAR ALICE HMPID prototype in STAR
Prototype successfully tested and used in STAR
See talk of Nikolai Smirnov
Itzhak TserruyaItzhak Tserruya RICH 2004, Playa del CarmenRICH 2004, Playa del Carmen 1515
Summary
No one has used a dry room for CsI No one has used a dry room for CsI handling. If we want to use we will have to handling. If we want to use we will have to prove that it does not affect the QE.prove that it does not affect the QE.
There is a lot of experience and know how There is a lot of experience and know how around around A. Braem from CERN A. Braem from CERN
16
Mauro Iodice – RICH2004 - Playa del Carmen, Mexico - Nov.30 Dec. 5, 2004
PLAYA Del CARMEN Event Display …there are rings too!