item no. · copper circuit conductors. paid for in structural plans. sheets) and insulated green...
TRANSCRIPT
ITEM NO.
PAY
SHEET
REF.
FINALPLANFINAL PLANFINALPLAN FINALPLAN
DESCRIPTION
SHEET NUMBERS
UNIT
FINALPLANFINAL PLANFINALPLAN FINALPLAN PLANFINALPLANFINALPLAN FINALPLANFINAL
TOTAL
GRAND
SHEET
THIS
TOTAL
L-8 L-9 L-10 L-11 L-12 L-13 L-14 L-15 L-16 L-17
EA
EA
EA
LS
EA
EA
EA
EA
LF
LF
LF
LF
AS
EA
LF
LF
-
-
-
-
-
-
-
-
-
1438
269
-
-
1
-
490
-
-
-
-
-
-
-
-
-
2097
-
-
-
1
-
699
-
-
-
-
-
-
-
-
-
2097
-
-
-
1
-
699
-
-
-
-
-
-
-
-
-
2046
-
-
-
-
-
682
-
-
-
-
-
-
-
-
-
2079
275
-
-
2
-
704
-
-
-
-
-
-
-
-
-
2100
-
-
-
-
-
700
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-2
TABULATION OF QUANTITIES
715-515-145
715-500-3
715-500-1
715-50
715-11-126
715-7-11
715-4-122
715-4-121
715-1-13
715-1-12
715-1-11
639-2-1
639-1-122
635-2-11
630-2-14
630-2-11
Light Pole Comp.-Sp. Design (F&I)(Bridge Mt.)(Al)(45')
Light Pole Cable Distribution System (Wall mount)
Light Pole Cable Distribution System (Conventional)
Lighting- Inside Box Girder
Luminaire (F&I) (Underdeck) (Pendant hung)
Load Center (F&I) Secondary Voltage
Light Pole Complete (F&I) (130 MPH) (45')
Light Pole Complete (F&I) (130 MPH) (40')
Lighting - Conductors (F&I) (No. 4 to No. 2)
Lighting - Conductors (F&I) (No. 8 to No. 6)
Lighting - Conductors (F&I) (No.10 or smaller)
Electrical Service Wire (F&I)
Electrical Power Service (F&I) (UG) (Meter Purch.)
Pull & Splice Box (F&I) (13" x 24")
Conduit (F&I) (Aboveground)
Conduit (F&I) (Underground)
2
2
6
-
-
-
6
-
4353
1522
-
-
-
12
-
1328
-
-
7
-
-
-
7
-
3639
1590
180
-
-
8
-
1412
-
-
9
-
-
-
2
7
5928
1612
-
-
-
20
-
2028
-
-
-
-
-
-
-
-
4533
1614
-
-
-
13
-
1663
2
2
22
0
0
0
15
7
18453
18195
724
0
0
58
0
10405
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
EA
EA
EA
LS
EA
EA
EA
EA
LF
LF
LF
LF
AS
EA
LF
LF
715-515-145
715-500-3
715-500-1
715-50
715-11-126
715-7-11
715-4-122
715-4-121
715-1-13
715-1-12
715-1-11
639-2-1
639-1-122
635-2-11
630-2-14
630-2-11
Light Pole Comp.-Sp. Design (F&I)(Bridge Mt.)(Al)(45')
Light Pole Cable Distribution System (Wall mount)
Light Pole Cable Distribution System (Conventional)
Lighting- Inside Box Girder
Luminaire (F&I) (Underdeck) (Pendant hung)
Load Center (F&I) Secondary Voltage
Light Pole Complete (F&I) (130 MPH) (45')
Light Pole Complete (F&I) (130 MPH) (40')
Lighting - Conductors (F&I) (No. 4 to No. 2)
Lighting - Conductors (F&I) (No. 8 to No. 6)
Lighting - Conductors (F&I) (No.10 or smaller)
Electrical Service Wire (F&I)
Electrical Power Service (F&I) (UG) (Meter Purch.)
Pull & Splice Box (F&I) (13" x 24")
Conduit (F&I) (Aboveground)
Conduit (F&I) (Underground)
ITEM NO.
PAY
SHEET
REF.
FINALPLANFINAL PLANFINALPLAN FINALPLAN
DESCRIPTION
SHEET NUMBERS
UNIT
FINALPLANFINAL PLANFINALPLAN FINALPLAN PLANFINALPLANFINALPLAN FINALPLANFINAL
TOTAL
GRAND
SHEET
THIS
TOTAL
L-18 L-19 L-20 L-21 L-22 L-23 L-24 L-25 L-26 L-30
-
-
6
-
-
-
-
6
2109
-
-
-
-
6
-
703
-
-
7
-
-
-
-
7
2274
2187
-
-
-
15
-
1487
-
-
3
-
-
-
-
3
1767
705
-
-
-
8
-
823
-
-
-
-
4
-
-
-
-
-
783
-
-
11
215
42
-
-
-
-
2
-
-
-
-
-
321
-
-
2
107
-
-
-
-
1
-
-
-
-
-
-
7630
-
-
30
1090
-
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-3
TABULATION OF QUANTITIES
-
-
6
-
-
1
-
6
3790
760
240
150
1
13
-
1154
-
-
-
-
-
-
-
-
2337
4198
-
-
-
18
127
1140
-
-
5
-
-
-
-
5
1392
219
-
-
-
5
-
537
-
-
-
-
-
1
-
-
1488
2976
39
28
1
7
-
537
0
0
27
1
6
2
0
27
15157
11045
9013
178
2
115
1539
6423
2
2
49
1
6
2
15
34
33610
29240
9737
178
2
173
1539
16828
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
CONVENTIONAL LIGHTING DESIGN CRITERIA
AVERAGE INITIAL INTENSITY
UNIFORMY RATIO AVG./MIN.
MAX./MIN.
B-2-300
4:1 OR LESS
10:1 OR LESS
2"
POLE IDENTIFICATION TAG DETAIL
N.T.S.
1.5 F.C. (DESIRED)
POLE NUMBER
NOTE 12
SEE GENERAL
(NO SCREWS)
FASTEN WITH RIVETS
CIRCUIT NUMBER
DESIGNATION
LOAD CENTER
PLAN SHEET LEGEND
SYMBOL SYMBOL
LOCAL DISCONNECT
SWITCH (TYP.)
2-#10
1-#10(G)
2-#10
1-#10(G)
2-#10
1-#10(G)
2-#10
1-#10(G)
STRUCTURE
SIGN
PULL BOX
ROADSIDE
LIGHTED SIGNS WIRING DETAIL
N.T.S.
LIG
HTIN
G C
KT.
LIG
HTIN
G C
KT.
EXISTING ROADWAY LIGHT POLE COMPLETE TO REMAIN.
PATHS AVERAGE INITIAL INTENSITY
SIDEWALKS AND SHARED USED 2.5 F.C. (DESIRED)
CONDUIT PROPOSED BY CONTRACTOR. MINIMUM PULL BOX DIMENSION IS 15" X 15" X 12".
CONTRACTOR. THE TYPE AND SIZE OF PULL BOXES TO BE CONSISTENT WITH CONDUIT AND FINAL LAYOUT OF
SURFACE MOUNT CONDUIT LAYOUT IN PLANS IS SCHEMATIC IN NATURE, AND MAY BE MODIFIED BY THE
SURFACE MOUNT PULL BOX (SEE ROADWAY AND TRAFFIC DESIGN STANDARDS BOOKLET DATED JANUARY 20140).
SERVICE POINT. FOR REQUIREMENTS SEE INDEX 17504 OF DESIGN STANDARDS.
THE PRICE OF THE PULL BOX.
"STREET LIGHTING" LOGO. SYMBOL INCLUDES PULL BOX CONCRETE SLAB WHICH IS PAID FOR IN
CROSSINGS AND AS NECESSARY FOR COMPLETION OF THE PROJECT. PULL BOX COVER SHALL HAVE
PULL BOXES WITH CONCRETE SLAB REQUIRED AT BOTH ENDS OF THE CONDUIT AT ROADWAY
PULL BOX (SEE INDEX 17500 DESIGN STANDARDS BOOKLET DATED JANUARY 2014).
WIND SPEED 130 MPH (ORANGE COUNTY)
VEILING LUMINANCE RATIO 0.3:1 OR LESS
AVERAGE INITIAL INTENSITY
UNIFORMY RATIO AVG./MIN.
MAX./MIN.
4:1 OR LESS
10:1 OR LESS
1.5 F.C. (DESIRED)
WIND SPEED 130 MPH (ORANGE COUNTY)
VEILING LUMINANCE RATIO 0.3:1 OR LESS
UNDERDECK LIGHTING DESIGN CRITERIA
DESCRIPTION DESCRIPTION
DISTRIBUTION SYSTEM ARE PAID FOR AS SEPARATE PAY ITEMS.
CONCRETE SLAB IS INCLUDED IN THE PRICE OF THE LIGHT POLE COMPLETE AND THE PULL BOX AND POLE CABLE
APPROVED EQUAL. SYMBOL INCLUDES CONCRETE SLAB, PULL BOX, AND POLE CABLE DISTRIBUTION SYSTEM. THE
MOUNTING HEIGHT OF 45'. GE MODEL M-400 SERIES LUMINAIRE PHOTOMETRIC CURVE #35-451002 OR AUTHORITY
FOR MEDIUM CUTOFF, TYPE III DISTRIBUTION, AUTO REGULATOR TYPE BALLAST WIRED FOR 480 VOLT OPERATION.
45' SHOULDER MOUNTED 400 WATT HIGH PRESSURE SODIUM (HPS) LIGHT POLE COMPLETE DESIGNED
DISTRIBUTION SYSTEM ARE PAID FOR AS SEPARATE PAY ITEMS.
CONCRETE SLAB IS INCLUDED IN THE PRICE OF THE LIGHT POLE COMPLETE AND THE PULL BOX AND POLE CABLE
APPROVED EQUAL. SYMBOL INCLUDES CONCRETE SLAB, PULL BOX, AND POLE CABLE DISTRIBUTION SYSTEM. THE
MOUNTING HEIGHT OF 40'. GE MODEL M-400 SERIES LUMINAIRE PHOTOMETRIC CURVE #35-451045 OR AUTHORITY
FOR MEDIUM CUTOFF, TYPE III DISTRIBUTION, AUTO REGULATOR TYPE BALLAST WIRED FOR 480 VOLT OPERATION.
40' SHOULDER MOUNTED 250 WATT HIGH PRESSURE SODIUM (HPS) LIGHT POLE COMPLETE DESIGNED
THESE ITEMS ARE PAID FOR AS SEPARATE PAY ITEMS. SEE STRUCTURAL PLANS REGARDING INSTALLATION DETAILS.
APPROVED EQUAL. SYMBOL INCLUDES EMBEDDED PULL BOX AND POLE CABLE DISTRIBUTION SYSTEM; HOWEVER,
MOUNTING HEIGHT OF 45'. GE MODEL M-400 SERIES LUMINAIRE PHOTOMETRIC CURVE #35-451002 OR AUTHORITY
FOR MEDIUM CUTOFF, TYPE III DISTRIBUTION, AUTO REGULATOR TYPE BALLAST WIRED FOR 480 VOLT OPERATION.
45' BRIDGE MOUNTED 400 WATT HIGH PRESSURE SODIUM (HPS) LIGHT POLE COMPLETE DESIGNED
MOUNT PULL BOX.
SPIKES. FIXTURE SHALL BE PENDANT HUNG (SEE DETAIL SHEET L-264). SYMBOL INCLUDES SURFACE
MEDIUM, MODEL NUMBER CAN-EDG-5M-PD-12-D-UH-BK-350-43K OR AUTHORITY APPROVED EQUAL WITH BIRD
UNDERDECK LED LUMINAIRES BASIS OF DESIGN IS CREE LIGHTING THE EDGE CANOPY LUMINAIRE TYPE V
CU BOND WIRE CONNECTING ALL POLES AND INSULATED STRANDED COPPER CIRCUIT CONDUCTORS.
INSIDE (CONDUCTOR AND GROUND WIRE SIZES SHOWN ON PLAN SHEETS) AND INSULATED GREEN STRANDED
PROPOSED 2" SCHEDULE 40 P.V.C. UNDERGROUND CONDUIT WITH TYPE THWN-2 STRANDED COPPER CONDUCTORS
TRENCH PRIOR TO CONSTRUCTION OF NEW ROADWAY PAVEMENT.
PROVIDED FOR CONDUCTORS AND ONE CONDUIT PROVIDED AS A SPARE. CONDUIT TO BE PLACED IN OPEN
WIRE CONNECTING ALL POLES AND INSULATED STRANDED COPPER CIRCUIT CONDUCTORS. ONE CONDUIT
(CONDUCTOR AND GROUND WIRE SIZES SHOWN ON PLAN SHEETS) AND INSULATED GREEN STRANDED CU BOND
PROPOSED 2" SCHEDULE 40 HDPE UNDERGROUND CONDUIT WITH TYPE THWN-2 STRANDED COPPER CONDUCTORS
COPPER CIRCUIT CONDUCTORS. PAID FOR IN STRUCTURAL PLANS.
SHEETS) AND INSULATED GREEN STRANDED CU BOND WIRE CONNECTING ALL POLES AND INSULATED STRANDED
CONDUCTORS INSIDE FOR UNDERDECK LIGHTING (CONDUCTOR AND GROUND WIRE SIZES SHOWN ON PLAN
COPPER CONDUCTORS INSIDE FOR CONVENTIONAL LIGHTING OR TYPE RHW OR THW STRANDED COPPER
PROPOSED 2" P.V.C. CONDUIT EMBEDDED IN CONCRETE BRIDGE RAIL OR WALL WITH TYPE THWN-2 STRANDED
CU BOND WIRE CONNECTING ALL POLES AND INSULATED STRANDED COPPER CIRCUIT CONDUCTORS.
LIGHTING (CONDUCTOR AND GROUND WIRE SIZES SHOWN ON PLAN SHEETS) AND INSULATED GREEN STRANDED
FOR CONVENTIONAL LIGHTING OR TYPE RHW OR THW STRANDED COPPER CONDUCTORS INSIDE FOR UNDERDECK
1" RGS GALVANIZED CONDUIT SURFACE MOUNT WITH TYPE THWN-2 STRANDED COPPER CONDUCTORS INSIDE
AVERAGE INITIAL INTENSITY
OVERHEAD SIGN LIGHTING DESIGN CRITERIA
15 F.C. MIN. TO 20 F.C. MAX
UNIFORMY RATIO MAX./MIN. 6:1 OR LESS
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-6
PLAN SHEET LEGEND
IS INCLUDED IN THE PRICE OF THE PULL BOX.
IN SR 429-203 (PHASE I) AND SHALL BE PAID FOR UNDER ITEM 635-2-11 PULL & SPLICE BOX. THE CONCRETE SLAB
SR 429-203A (PHASE II) FUTURE LIGHT POLE COMPLETE ASSEMBLY. CONCRETE SLAB AND PULL BOX TO BE INSTALLED
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
RAILING/BARRIER PER FDOT SPECIFICATIONS.
UNDER STRUCTURAL CONTRACT. EMBEDDED PULL BOXES SHALL OPEN FROM THE BACK SIDE OF THE TRAFFIC
WALL OR BRIDGE EMBEDDED PULL BOX INTEGRAL TO STRUCTURE (1'-6" X 1'-6" X 8" MAX.) PAID AND INSTALLED
SR 429 POLE DATA
CIRCUIT STATION POLE SETBACK PAY ITEM NO.
POLE
OR ARM
DIST.
WATTAGE
LUMINAIRE
HEIGHT
MOUNTING
CIRCUIT STATION POLE SETBACK PAY ITEM NO.
POLE
OR ARM
DIST.
WATTAGE
LUMINAIRE
HEIGHT
MOUNTING
RAMP A POLE DATA
CIRCUIT STATION POLE SETBACK PAY ITEM NO.
POLE
OR ARM
DIST.
WATTAGE
LUMINAIRE
HEIGHT
MOUNTING
RAMP B POLE DATA
116
115
114
113
112
111
110
109
108
107
106
105
104
103
102
101
100
A-1
A-2
A-1
A-2
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
296+69.71
296+32.00
295+38.00
294+44.00
293+50.01
292+56.00
291+62.01
290+68.00
289+74.01
288+79.99
287+86.00
286+92.00
285+98.00
285+04.00
284+10.00
283+16.00
282+22.00
15'
15'
15'
15'
15'
15'
15'
15'
15'
15'
10'
10'
15'
15'
15'
15'
15'
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
45'
14' FROM E.O.T.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
BRIDGE MOUNTED
BRIDGE MOUNTED
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
SR 429 UNDERDECK LIGHTS
NO.
LUM.
WATTAGE
LUMINAIREPAY ITEMSTATIONCIRCUIT
HEIGHT
MOUNTINGLUMINAIRES/PENDANT OFFSET
CIRCUIT STATION NO.
SIGN
LIGHTED SIGNS
(FT)
ARM L.
215
214
213
212
211
210
209
208
207
206
205
204
203
202
201
200
A-2
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
A-1
1313+40.00
1312+36.00
1311+32.00
1310+28.00
1309+24.00
1308+20.00
1307+16.03
1306+12.06
1305+07.94
1304+03.97
1303+00.00
1301+96.00
1300+91.99
1299+88.06
1298+84.03
1297+80.01
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
14' FROM E.O.T.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
5' BEHIND F.O. GRDRL.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
317
316
315
314
313
312
311
310
309
308
307
306
305
304
303
302
301
300
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-3
A-2
2314+93.66
2313+93.00
2312+88.88
2311+95.08
2310+91.18
2309+86.86
2308+82.94
2307+79.01
2306+75.02
2305+71.00
2304+67.00
2303+63.01
2302+58.99
2301+54.94
2300+43.45
2299+44.22
2298+43.04
2297+38.99
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
250 W
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
40'
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
14' FROM E.O.T.
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
715-4-121
132 W
132 W
132 W
132 W
132 W
132 W
16'-6"
16'-6"
16'-6"
16'-6"
16'-6"
16'-6"
UD-6
UD-5
UD-4
UD-3
UD-2
UD-1
A-4
A-4
A-4
A-4
A-4
A-4
286+93.04
287+53.04
286+93.04
287+53.04
313+52.61
313+51.05
52.0' RT ¡ SR 429
52.0' RT ¡ SR 429
52.0' LT ¡ SR 429
52.0' LT ¡ SR 429
62.1' LT ¡ SR 429
62.1' RT ¡ SR 429
715-11-126
715-11-126
715-11-126
715-11-126
715-11-126
715-11-126
NO.
STR.
25
23
16
14
12
B-1
A-1
A-2
A-4
A-4
(WxH)
SIGN DIM.
WATTAGE
LUMINAIRE
104 W
104 W
104 W
104 W
104 W
LUM.
NO. OF
2
2
2
2
2
4
4
4
4
4
OC-11
OC-9
OC-4
OC-3
OC-2
15'-0"x15'-6" / 15'-0"x3'-0"
15'-0"x14'-0" / 15'-0"x3'-0"
21'-6"x5'-6" / 21'-6"x3'-0"
18'-0"x7'-0" / 18'-0"x3'-0"
18'-0"x7'-0" / 18'-0"x3'-0"
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
715-515-145
715-515-145
715-4-122
715-4-122
715-4-122
715-4-122
715-4-122
86+00.00 ¡ KELLY PARK RD
78+81.00 ¡ KELLY PARK RD
2295+19.00 £ RAMP B
368+65.00 � NB SR 429
242+14.41 ¡ SR 429
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-7
POLE DATA SHEETCERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
ME
TA
L
ME
TA
L
341 342 343 344 345 346 347
140141
142143
144145 146
240 241 242 243 244 245 246 247
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
50
Feet
0 10
N
R/W LINE
1-#6 (G)
2-#6, A-41-#10 (G)
2-#10, A-4
SIGN 12 OC-2, CKT. A-4
STA. 242+14.41
¡ SR 429 (WEKIVA PKWY)
{ CONST. SR 429
STA. 242+14.41
BEGIN LIGHTING 429-203
MA
TC
HLIN
E S
TA.
247
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-8 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
WO
OD
WO
OD
348349
350351
352353
354
147 148 149 150 151 152 153
247 248 249 250 251 252 253 254
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
R/W LINE
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
MA
TC
HLIN
E S
TA.
254
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
247
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-9 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
ME
TA
L
WO
OD
WO
OD
WO
OD
355 356357
358359
360361
154155 156 157 158 159
160
254255
256 257 258 259260
261
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10N
1-#6 (G)
2-#6, A-4
R/W LINE
1-#6 (G)
2-#6, A-4
MA
TC
HLIN
E S
TA.
261
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
254
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-10 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
361362
363364 365 366 367
161162 163 164 165 166
167
261262
263 264 265 266267
268
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
1-#6 (G)
2-#6, A-4
MA
TC
HLIN
E S
TA.
261
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
268
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-11 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
368
369
370
371372
373374
168169 170 171 172 173 174
268269 270 271 272 273 274 275
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
R/W LINE
1-#6 (G)
2-#6, A-4
R/W LINE
SIGN 14 OC-3, CKT. A-4
STA. 368+65.00
1-#10 (G)
2-#10, A-4
MA
TC
HLIN
E S
TA.
268
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
275
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-12 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
375376
377378 379 380 381
175 176 177 178 179 180 181
275 276 277 278 279 280 281 282
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
1-#6 (G)
2-#6, A-4
R/W LINE
R/W LINE
MA
TC
HLIN
E S
TA.
275
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
282
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-13 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
282 283 284 285 286 287 288 289
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
1-#4 (G)
2-#4, A-1
1-#4 (G)
2-#4, A-11-#4 (G)
2-#4, A-1
1-#4 (G)
2-#4, A-1
R/W LINE
R/W LINE
POLE NO. 100, CKT. A-1
STA. 282+22.00POLE NO. 102, CKT. A-1
STA. 284+10.00 POLE NO. 104, CKT. A-1
STA. 285+98.00
POLE NO. 106, CKT. A-1
STA. 287+86.00
POLE NO. 101, CKT. A-1
STA. 283+16.00POLE NO. 103, CKT. A-1
STA. 285+04.00POLE NO. 105, CKT. A-1
STA. 286+92.00
POLE NO. 107, CKT. A-1
STA. 288+79.99
1-#4 (G)
2-#4, A-1
1-#4 (G)
2-#4, A-1
SPARE
1-#4 (G)
2-#4, A-1
1-#4 (G)
2-#4, A-1
SPARE
1-#6 (G)
2-#6, A-4
1-#4 (G)
2-#6, A-4
2-#4, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-1
LIGHTING DETAILS.
SEE SHEET NO. L-25 FOR UNDERDECK
NOTE:
1-#4 (G)
2-#6, A-4
2-#4, A-1
MA
TC
HLIN
E S
TA.
282
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
289
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-14 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
289 290 291 292 293 294 295 296
12951296
2294 2295
2296
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N1-#4 (G)
2-#4, A-1
1-#4 (G)
2-#4, A-1
1-#2 (G)
2-#2, A-1
R/W LINE
1-#2 (G)
2-#2, A-11-#2 (G)
2-#2, A-1
POLE NO. 108, CKT. A-1
STA. 289+74.01
POLE NO. 110, CKT. A-1
STA. 291+62.01POLE NO. 112, CKT. A-1
STA. 293+50.01
POLE NO. 109, CKT. A-1
STA. 290+68.00
POLE NO. 111, CKT. A-1
STA. 292+56.00
1-#6 (G)
2-#6, A-4
1-#4 (G)
2-#6, A-4
2-#4, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-1
SIGN 16 OC-4, CKT. A-2
STA. 2295+19.00
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#10 (G)
2-#10, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
POLE NO. 114, CKT. A-1
STA. 295+38.00
POLE NO. 113, CKT. A-2
STA. 294+44.00
3
MA
TC
HLIN
E S
TA.
289
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
296
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-15 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
296 297 298 299 300 301 302 303
1296
1297
1298
1299
1300
1301
2296
2297
2298
2299
2300
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
RAMP A
RAMP B
¡ SR 429 (WEKIVA PKWY)
£ RAMP A
£ RAMP B
50
Feet
0 10
N
R/W LINE
1-#2 (G)
2-#2, A-1
POLE NO. 201, CKT. A-1
STA. 1298+84.03
POLE NO. 302, CKT. A-3
STA. 2299+44.22
POLE NO. 300, CKT. A-2
STA. 2297+38.99
POLE NO. 301, CKT. A-3
STA. 2298+43.04
POLE NO. 202, CKT. A-1
STA. 1299+88.06
POLE NO. 203, CKT. A-1
STA. 1300+91.99
1-#2 (G)
2-#2, A-1
1-#4 (G)
2-#4, A-3
1-#6 (G)
2-#6, A-3
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#4 (G)
2-#4, A-3 1-#4 (G)
2-#4, A-3
POLE NO. 200, CKT. A-1
STA. 1297+80.01
1-#2 (G)
2-#2, A-1
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
SPARE
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-3
SPARE
SPARE
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-3
SPARE
POLE NO. 116, CKT. A-1
STA. 296+69.71
POLE NO. 115, CKT. A-2
STA. 296+32.00
FUTURE INSTALLATION
PHASE II (POLE 122)
FUTURE INSTALLATION
PHASE II (POLE 120)
FUTURE INSTALLATION
PHASE II (POLE 118)
FUTURE INSTALLATION
PHASE II (POLE 117)
FUTURE INSTALLATION
PHASE II (POLE 119)
FUTURE INSTALLATION
PHASE II (POLE 121)
£ R
AM
P B,
SE
E S
HE
ET L-21
MA
TC
HLIN
E S
TA. 2300+00.0
0
£ R
AM
P A,
SE
E S
HE
ET L-19
MA
TC
HLIN
E S
TA.
1301+00.0
0
50
Feet
0 10
N
MA
TC
HLIN
E S
TA.
296
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
303
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-16 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
303 304 305 306 307 308 309 310
5306
5307
5308
5309
5310
SR 429 SOUTHBOUND
SR 429 NORTHBOUND
¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
1-#4 (G)
2-#4, A-21-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
SPARE
1-#4 (G)
2-#4, A-3 1-#4 (G)
2-#4, A-31-#4 (G)
2-#4, A-3
1-#6 (G)
2-#6, A-4
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-2
1-#6 (G)
2-#6, A-4
£ RAMP B1
FUTURE INSTALLATION
PHASE II (POLE 124)FUTURE INSTALLATION
PHASE II (POLE 126)FUTURE INSTALLATION
PHASE II (POLE 128)
(OC-6 SIGN 20)
INSTALLATION
FUTURE SIGN
PHASE II
FUTURE INSTALLATION
PHASE II (POLE 123)
FUTURE INSTALLATION
PHASE II (POLE 125)
FUTURE INSTALLATION
PHASE II (POLE 127)
(OC-5 SIGN 17)
INSTALLATION
FUTURE SIGN
PHASE II
FUTURE INSTALLATION
PHASE II (POLE 129)
FUTURE INSTALLATION
PHASE II (POLE 418)
FUTURE INSTALLATION
PHASE II (POLE 417)
FUTURE INSTALLATION
PHASE II (POLE 416)
MA
TC
HLIN
E S
TA.
303
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
MA
TC
HLIN
E S
TA.
310
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
£ RAMP B1, SEE L-22
MATCHLINE STA. 5306+00.00,
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-17 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
OHD CABLE
WO
OD
WO
OD
WO
OD
310 311 312 313 314 315 316 317
82
83
84
85
5289
5290
5291
5292
5310 5311 5312
145
146
147
148
SR 429 NORTHBOUND
SR 429 SOUTHBOUND¡ SR 429 (WEKIVA PKWY)
50
Feet
0 10
N
KE
LL
Y P
AR
K R
D
1-#4 (G)
2-#4, A-3
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
1-#4 (G)
2-#4, A-3
1-#6 (G)
2-#6, A-4
1-#6 (G)
2-#6, A-4
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-3
¡ KELLY PARK RD.
£ RAMP B1
1-#6 (G)
6-#6, B-4
2-#6, A-4
1-#6 (G)
6-#6, B-4
2-#6, A-4
1-#6 (G)
6-#6, B-4
2-#6, A-4
1-#6 (G)
6-#6, B-4
2-#6, A-4
1-#6 (G)
6-#6, B-4
2-#6, A-4
1-#4 (G)
6-#6, B-4
2-#4, B-1 1-#10 (G)
6-#10, B-4
FUTURE INSTALLATION
PHASE II (POLE 130)
CKT. A-
3
CK
T. A
-4
CKT.
A-4
CKT.
A-3
(OC-10 SIGN 24)
INSTALLATION
FUTURE SIGN
PHASE II
CK
T.
A-2
FUTURE INSTALLATION
PHASE II (POLE 132)
FUTURE INSTALLATION
PHASE II (POLE 133)
FUTURE INSTALLATION
PHASE II (POLE 402)
FUTURE INSTALLATION
PHASE II (POLE 131)
FUTURE INSTALLATION
PHASE II (POLE 134)
FUTURE INSTALLATION
PHASE II (POLE 401)
FOR MAINTENANCE LIGHTING DETAILS.
LIGHTING DETAILS AND SHEET NO. L-30
SEE SHEET NO. L-26 FOR UNDERDECK
NOTE:
S
S
S
S
S
S
S
S
S
S
S
S
£ RAMP B1, SEE SHEET L-23
MATCHLINE STA. 5292+00.00
¡ KELLY PARK RD., SEE SHEET L-20MATCHLINE STA. 82+00,
MA
TC
HLIN
E S
TA.
310
+00.0
0 ¡ S
R 429 (W
EKIV
A P
KW
Y.)
¡ KELLY PARK RD., SEE SHEET L-24MATCHLINE STA. 85+60.00,
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
SR 429LIGHTING PLAN
L-18 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
94.00' LT.
+83.84
13011302
13031304
1305 13061307
1308
POLE NO. 204, CKT. A-1
STA. 1301+96.00
POLE NO. 205, CKT. A-1
STA. 1303+00.00POLE NO. 206, CKT. A-1
STA. 1304+03.97POLE NO. 207, CKT. A-1
STA. 1305+07.94
POLE NO. 208, CKT. A-1
STA. 1306+12.06
POLE NO. 209, CKT. A-1
STA. 1307+16.03
1-#2 (G)
2-#2, A-11-#2 (G)
2-#2, A-1 1-#2 (G)
2-#2, A-1 1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
R/W LINE
RAMP A
50
Feet
0 10
N
£ RAMP A
MA
TC
HLIN
E S
TA.
1301
+00.0
0 £ R
AM
P
A,
SE
E S
HE
ET L-16
SE
E S
HE
ET L-20
MA
TC
HLIN
E S
TA.
1308
+00.0
0 £ R
AM
P
A
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
RAMP ALIGHTING PLAN
L-19 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
13081309 1310 1311 1312 1313
1314
4313
78
79
80
81
82
5288
141
142
143
144
145
POLE NO. 210, CKT. A-1
STA. 1308+20.00
POLE NO. 211, CKT. A-1
STA. 1309+24.00
POLE NO. 212, CKT. A-1
STA. 1310+28.00
POLE NO. 213, CKT. A-1
STA. 1311+32.00
POLE NO. 214, CKT. A-1
STA. 1312+36.00
POLE NO. 215, CKT. A-2
STA. 1313+40.00
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#2, A-1
SPARE
R/W LINE
R/W LINE
RAMP A
CKT.
A-1
1-#2 (G)
2-#2, A-1
1-#2 (G)
2-#6, A-4
2-#4, A-3
2-#2, A-2
2-#2, A-1
1-#2 (G)
2-#6, A-4
2-#4, A-3
2-#2, A-2
2-#2, A-1SIGN 23 OC-9, CKT. A-1
STA. 78+81.00
1-#10 (G)
2-#10, A-1
SERVICE
POWER
EXIST.
1-#2 (G)
2-#6, A-4
2-#4, A-3
2-#2, A-2
1-#2 (G)
2-#6, A-4
2-#4, A-3
2-#2, A-2
1-#2 (G)
2-#6, A-4
2-#4, A-3
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#4 (G)
2-#6, A-4
2-#4, A-3
N
50
Feet
0 10
KE
LL
Y P
AR
K R
OA
D
CK
T. A
-4
CK
T. A
-3
CK
T. A
-2
CK
T.
A-2
CKT. A-4
CKT. A-3
£ RAMP A
PARK RD.
¡ CONST. KELLY
A-2 45A, CKT. A-3 35A, AND CKT. A-4 15A).
175A MAIN CIRCUIT BREAKER, 4 BRANCH CIRCUITS (CKTS. A-1 &
240/480V, SINGLE PHASE, 3-WIRE UNDERGROUND SERVICE,
LOAD CENTER 'A' STA. 78+94.35, 98.5' RT, ¡ CONST. KELLY PARK ROAD
FUTURE INSTALLATION
PHASE II (POLE 400)
� KELLY PARK RD, SEE SHEET L-18
MATCHLINE STA. 82+00.00,
CIRCUITFIXTURES
NO. OF
WATTAGE
FIXTURE
(VOLTS)
V
A-4
A-3
A-2
A-1
LOAD
VA
15
35
45
45
100
104
132
250
400
100
104
132
250
400
100
104
132
250
400
100
104
132
250
400
0
4
6
0
0
0
0
0
17
0
0
2
0
2
2
0
2
0
15
15
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
480
SE
E S
HE
ET L-19
MA
TC
HLIN
E S
TA.
1308
+00.0
0 £ R
AM
P
A
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
RAMP ALIGHTING PLAN
L-20
(AMPS)
AMPACITY
(AMPS)BREAKERCIRCUITBRANCH
(AMPS)BREAKERCIRCUIT
MAIN
VA LOADCENTER
LOAD
0
1.2
1.8
0
0
0
0
0
11.9
0
0
0.6
0
1.4
2.2
0
0.6
0
10.5
16.50
0
576
864
0
0
0
0
0
5712
0
0
288
0
672
1056
0
288
0
5040
7920
175 22,416
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
2300
2301
23022303 2304 2305
POLE NO. 303, CKT. A-3
STA. 2300+43.45
POLE NO. 304, CKT. A-3
STA. 2301+54.94 POLE NO. 305, CKT. A-3
STA. 2302+58.99
POLE NO. 306, CKT. A-3
STA. 2303+63.01
POLE NO. 307, CKT. A-3
STA. 2304+67.00
1-#4 (G)
2-#4, A-3
1-#4 (G)
2-#4, A-31-#4 (G)
2-#4, A-31-#4 (G)
2-#4, A-31-#6 (G)
2-#6, A-3
R/W LINE
RAMP B
1-#4 (G)
2-#4, A-3
N
50
Feet
0 10
£ RAMP B£ R
AM
P B,
SE
E S
HE
ET L-16
MA
TC
HLIN
E S
TA.
2300+00.0
0
SE
E S
HE
ET L-22
MA
TC
HLIN
E S
TA.
2305
+40.0
0 £ R
AM
P B
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
RAMP BLIGHTING PLAN
L-21 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
5298
5299
5300
53015302
5303
5304
5305
5306
2306 23072308
2309
2310
2311
2312
POLE NO. 308, CKT. A-3
STA. 2305+71.00
POLE NO. 309, CKT. A-3
STA. 2306+75.02POLE NO. 310, CKT. A-3
STA. 2307+79.01
POLE NO. 311, CKT. A-3
STA. 2308+82.94
POLE NO. 312, CKT. A-3
STA. 2309+86.86
POLE NO. 313, CKT. A-3
STA. 2310+91.18
POLE N
O. 3
15, C
KT. A-3
STA. 2
312+88.88
1-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-31-#6 (G)
2-#6, A-31-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-3
POLE NO. 314, CKT. A-3
STA. 2311+95.08
1-#6 (G)
2-#6, A-3
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
1-#4 (G)
2-#4, A-2
R/W LINE
N
50
Feet
0 10
RAMP B
£ RAMP B1
£ RAMP B
FUTURE INSTALLATION
PHASE II (POLE 415)
FUTURE INSTALLATION
PHASE II (POLE 414)
FUTURE INSTALLATION
PHASE II (POLE 413)
FUTURE INSTALLATION
PHASE II (POLE 412)
FUTURE INSTALLATION
PHASE II (POLE 411)
FUTURE INSTALLATION
PHASE II (POLE 410)
FUTURE INSTALLATION
PHASE II (POLE 409)
FUTURE INSTALLATION
PHASE II (POLE 408)
£ RAMP B1, SEE SHEET L-23
MATCHLINE STA. 5298+00.00
£ R
AM
P B,
SE
E S
HE
ET L-21
MA
TC
HLIN
E S
TA.
2305
+40.0
0
£ R
AMP B, S
EE S
HEET L-23
MATC
HLIN
E S
TA. 2
312+60.00
£ RAMP B
1, SEE S
HEET L-17
MATCHLINE S
TA. 5306
+00.00
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
RAMP BLIGHTING PLAN
L-22 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
5292
5293
5294
5295
5296
5297
5298
2313
2314
2315
POLE NO. 315, CKT. A-3
STA. 2312+88.88
POLE NO. 316, CKT. A-3
STA. 2313+93.00
1-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-3
1-#6 (G)
2-#6, A-3
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
1-#2 (G)
2-#2, A-2
RA
MP B
50
Feet
0 10
N
£ RAMP B1
POLE NO. 317, CKT. A-3
STA. 2314+93.66
£ RAMP BFUTURE INSTALLATION
PHASE II (POLE 403)
FUTURE INSTALLATION
PHASE II (POLE 404)
FUTURE INSTALLATION
PHASE II (POLE 405)
FUTURE INSTALLATION
PHASE II (POLE 406)
FUTURE INSTALLATION
PHASE II (POLE 407)
£ R
AM
P B
1,
SE
E S
HE
ET L-18
MA
TC
HLIN
E S
TA.
5292
+00.0
0
£ RAMP B, SEE SHEET L-24
MATCHLINE STA. 2315+40.00
£ RAMP B, SEE SHEET L-22
MATCHLINE STA. 2312+60.00
£ RAMP
B1, S
EE SHEET
L-22
MATCHLINE
STA. 52
98+0
0.00
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
RAMP BLIGHTING PLAN
L-23 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
3314
3315
3316
86 87 88 89 90 91 92
2316
149 150 151 152 153 154 155
SIGN 25 OC-11, CKT. B-1
STA. 86+00.00
1-#10 (G)
2-#10, B-1
SPARE SERVICE
POWER
EXIST.
N
50
Feet
0 10
1-#4 (G)
6-#6, B-4
2-#4, B-1
1-#4 (G)
6-#6, B-4
2-#4, B-1
1-#4 (G)
6-#6, B-4
2-#4, B-1
1-#4 (G)
6-#6, B-4
2-#4, B-1
1-#4 (G)
6-#6, B-4
2-#4, B-1
CKT. B-4 15A).
125A MAIN CIRCUIT BREAKER, 2 BRANCH CIRCUITS (CKT. B-1 30A,
240/480V, SINGLE PHASE, 3-WIRE UNDERGROUND SERVICE,
LOAD CENTER 'B' STA. 90+00.00, 45.0' LT, ¡ CONST. KELLY PARK ROAD
1-#4 (G)
6-#6, B-4
2-#4, B-1
FUTURE INSTALLATION
PHASE II (POLE 500)
(OC-12 SIGN 26)
SIGN INSTALLATION
PHASE II FUTURE
£ RAMP B, SEE SHEET L-23
MATCHLINE STA. 2315+40.00
SE
E S
HE
ET L-18
¡ C
ON
ST.
KE
LL
Y P
AR
K R
D.,
MA
TC
HLIN
E S
TA.
85
+60.0
0
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-24 KELLY PARK ROADLIGHTING PLAN
CIRCUITFIXTURES
NO. OF
WATTAGE
FIXTURE
(VOLTS)
V
LOAD
VA
(AMPS)
AMPACITY
(AMPS)BREAKERCIRCUITBRANCH
(AMPS)BREAKERCIRCUIT
MAIN
VA LOADCENTER
LOAD
125 3,744B-4
B-1
100
104
132
250
400
100
104
132
250
400
24
0
0
0
0
0
2
0
0
0
7.2
0
0
0
0
0
0.6
0
0
0
3456
0
0
0
0
0
288
0
0
0
480
480
480
480
480
480
480
480
480
480
15
30
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
286 287 288
N
5 20
Feet
0
1-#10 (G)
2-#10, A-4
THE PRECEDING SHEETS.
SHALL BE QUANTIFIED IN
ALL OTHER LIGHTING SHOWN
LUMINAIRES.
WELL AS THE PENDANT HUNG
UNDERDECK LIGHTING AS
PULL BOXES UTILIZED FOR
CONDUIT, CONDUCTORS, AND
SHEET ONLY INCLUDE THE
QUANTITIES FOR THIS
UNDERDECK LIGHTING.
DEPICT AND LABEL
INTENDED TO CLEARLY
THIS SHEET IS ONLY
NOTE:
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-41-#10 (G)
2-#10, A-4
¡ SR 429 (WEKIVA PKWY.)
UD-4, CKT. A-4STA. 286+93.04, 52.0' LT
UD-3, CKT. A-4STA. 287+53.04, 52.0' LT
UD-5, CKT. A-4STA. 287+53.04, 52.0' RT
UD-6, CKT. A-4STA. 286+93.04, 52.0' RT
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
PLANUNDERDECK LIGHTING
L-25 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
WO
OD
WO
OD
312 313 314 315
84
85
5290
5291
147
148
S
S
S
S
S
S
S
S
S
S
S
S
N
5 20
Feet
0
1-#10 (G)
2-#10, A-4
1-#10 (G)
2-#10, A-4
UD-1, CKT. A-4STA. 313+51.05, 62.1' RT
UD-2, CKT. A-4STA. 313+52.61, 62.1' LT
¡ SR 429 (WEKIVA PKWY.)
¡ CONST. KELLY PARK RD.
£ RAMP B1
SHEET NO. L-30.
SHALL BE QUANTIFIED ON
MAINTENANCE LIGHTING
THE PRECEDING SHEETS.
SHALL BE QUANTIFIED IN
ALL OTHER LIGHTING SHOWN
LUMINAIRES.
WELL AS THE PENDANT HUNG
UNDERDECK LIGHTING AS
PULL BOXES UTILIZED FOR
CONDUIT, CONDUCTORS, AND
SHEET ONLY INCLUDE THE
QUANTITIES FOR THIS
UNDERDECK LIGHTING.
DEPICT AND LABEL
INTENDED TO CLEARLY
THIS SHEET IS ONLY
NOTE:
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
PLANUNDERDECK LIGHTING
L-26 CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
"211'-6
LANE
12'-0"
LANE
12'-0"
SHLDR.
6'-0"
8" SLAB
10" SLAB
LANE
12'-0"
SHLDR.
10'-0" "211'-6
Slope: 0.02 Ft/Ft
SL
AB"
21
8
"211'-6
LANE
12'-0"
LANE
12'-0"
SHLDR.
6'-0"
LANE
12'-0"
SHLDR.
10'-0" "211'-6
Slope: 0.02 Ft/Ft
PARCEL 197 BRIDGE UNDERDECK LED LUMINAIRE
KELLY PARK ROAD BRIDGE UNDERDECK LED LUMINAIREN.T.S.
N.T.S.
DETAIL A
21210 (TYP.)
PER FDOT INDEX
UTILITY CONDUITS
2 ~ 2" � PVC
MOUNTING LOCATIONS
CONDUIT RUN AND
UNDERDECK LUMINAIRE
REFER TO L-25 FOR
MOUNTING LOCATIONS
CONDUIT RUN AND
UNDERDECK LUMINAIRE
REFER TO L-26 FOR
MOUNT J-BOX
LIGHTING SURFACE
CONDUIT TO UNDERDECK
1" RGS SURFACE MOUNT
MOUNT J-BOX
LIGHTING SURFACE
CONDUIT TO UNDERDECK
1" RGS SURFACE MOUNT
BEAM (TYP.)
FLORIDA U 48
INDEX 21210
(TYP.) SEE FDOT
UTILITY CONDUITS
2 ~ 2" � PVC
5. BOTTOM OF UNDERDECK LED LUMINAIRE NOT TO BE HUNG BELOW BEAM, 16'-6" MINIMUM MOUNTING HEIGHT.SHOP DRAWINGS DETAILING THE SUPPORT MEASURES. COST OF SUPPORT MEASURES SHALL BE INCLUDED IN PAY ITEM 715-11-126.4. CONTRACTOR SHALL PROVIDE ADEQUATE SUPPORT MEASURES TO PREVENT THE PENDANT HUNG UNDERDECK LUMINAIRES FROM SWAYING. CONTRACTOR SHALL SUBMIT 3. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS DETAILING MEMBER AND CONNECTION ELEMENT SIZES FOR ROADWAY UNDERDECK LED LIGHTING FIXTURES. WITH RUNS PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS.SERVICE POINT, UP PIER TO PIER CAP AND OVER TO LED LUMINAIRE LOCATION. NEW 1" RGS SURFACE MOUNTED CONDUITS SHALL BE CONCEALED AND INSTALLEDCONNECTIONS NECESSARY FOR COMPLETE SERVICE TO UNDERDECK LED LUMINARIES. ALL SURFACE MOUNTED CONDUIT IS REQUIRED TO GO FROM UNDERDECK2. CONTRACTOR SHALL CONNECT PROPOSED CONDUCTOR TO PROPOSED SERVICE POINT. CONTRACTOR SHALL INSTALL ALL CONDUCTORS AND SERVICE POINT1. ALL UNDERDECK LED LUMINARIES AND RELATED HARDWARE SHALL BE PAID FOR ON SHEETS L-25 AND L-26 IN THE COST OF PAY ITEM 715-11-126.NOTES:
THREADED BOTH ENDS
1" RGS CONDUIT
THREADED BOTH ENDS
1" RGS CONDUIT
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
UNDERDECK LIGHTING DETAIL L-27
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
10"
"2
18
LIGHTING TABULATION OF QUANTITIES AND ANY INCIDENTALS, NECESSARY FOR A COMPLETE AND ACCEPTED INSTALLATION.
715-50. THIS ITEM INCLUDES PAYMENT FOR ALL ITEMS, INCLUDING THE ITEMS LISTED IN THE BOX GIRDER MAINTENANCE
19. INCLUDE THE COST OF THE BOX MAINTENANCE LIGHTING SYSTEM IN THE PAY ITEM FOR LIGHTING - INSIDE BOX GIRDER,
PLANS.
OTHER TRADES TO AVOID CONFLICTS. COORDINATE ALL LIGHTING FIXTURES AND EQUIPMENT LOCATIONS WITH THE STRUCTURE
18. THESE DRAWINGS ARE NOT INTENDED TO SHOW THE EXACT LOCATION OF CONDUIT RUNS. COORDINATE THESE WITH THE
17. PROVIDE SIX HOUR RESET TIMERS FOR EACH CIRCUIT TO TURN OFF THE LIGHTING SYSTEM AUTOMATICALLY.
16. LOCATE SWITCHES AT EACH END OF EACH SPAN AND AT EVERY ACCESS DOOR.
BRASS BASE INCANDESCENT LAMPS.
GLOBES AND WIRE GUARDS AT 50' MAXIMUM ON CENTERS. PROVIDE 100 WATT, 130 VOLT, VIBRATION RESISTANT AND
15. FURNISH AND INSTALL SURFACE MOUNTED, FULLY ENCLOSED, INCANDESCENT LIGHT FIXTURES WITH GASKETED CLEAR
MAXIMUM WIRE SIZE TO CONNECT TO RECEPTACLES IS #12 AWG.
50' MAXIMUM ON CENTERS. PROVIDE EACH RECEPTACLE WITH A GASKETED WEATHER-PROTECTIVE OUTDOOR PLATE.
14. FURNISH AND INSTALL 120V DUPLEX RECEPTACLES (GFI, NEMA TYPE 5-20R), IN NON-METALLIC OUTLET BOXES AT
MOUNTED BOXES SIZED IN CONFORMANCE WITH THE NEC.
13. FURNISH AND INSTALL NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION (NEMA) TYPE 4X (NON-METALLIC) SURFACE
12. PROVIDE ENOUGH SLACK IN ALL INTERIOR CABLE TERMINATIONS TO ALLOW FOR MINOR SHIFTING OF THE STRUCTURE.
FIXTURE OUTLET STATION (FOS).
11. FURNISH AND INSTALL COPPER CONDUCTORS, TYPE XHHW. DO NOT USE ANY CONDUCTOR LARGER THAN #4 AWG IN A
10. FURNISH AND INSTALL LIGHTING CONTACTORS TO SWITCH THE 480V AC FEEDING THE MINI POWER CENTERS.
SEPARATION.
BRIDGE, PREFERABLY 500' ON EACH SIDE OF THE MINI POWER CENTER. 480V TOP FEED, 120V BOTTOM FEED TO MAINTAIN
OF 20 LAMPS AND 20 RECEPTACLES. EACH MINI POWER CENTER WILL PROVIDE POWER TO NO MORE THAN 1000' OF
7.5 KVA MINI POWER CENTER WITH EIGHT 20 AMP BREAKERS AS THE STEP DOWN TRANSFORMER, FEEDING A MAXIMUM
9. FURNISH POWER DISTRIBUTION AT 480V AC, I PHASE, WITH STEP DOWN TRANSFORMERS AT REGULAR INTERVALS. FURNISH
MOUNTING, DO NOT ATTACH FASTENERS TO MAIN MEMBERS, I.E. WEBS AND FLANGES.
CAUSED BY TRAFFIC. INSTALL FASTENERS TO AVOID CONFLICTS WITH REINFORCING STEEL AND PT DUCTS. FOR STRUCTURAL STEEL
SIP FORM MOUNTING, PROVIDE ANCHOR BOLTS (EXPANSION, DROP-IN OR ADHESIVE) SUITABLE FOR DYNAMIC LOADING (DUE TO VIBRATION
8. USE ONLY ALLOY 316 STAINLESS STEEL SUPPORTING HARDWARE. PROVIDE MINIMUM 3/16" DIAMETER FASTENERS. FOR CONCRETE OR
CONDUITS, WATERPROOF, UV PROTECTED AND ALLOWS LONGITUDINAL MOVEMENT EQUAL TO THAT OF THE EXPANSION JOINT.
CERTIFICATION THAT THE EXPANSION FITTING MEETS THE FOLLOWING MINIMUM REQUIREMENTS: COMPATIBILITY WITH THE CONNECTED
7. INSTALL A UL LABELED EXPANSION FITTING FOR SPECIFIED PVC CONDUIT AT ALL STRUCTURE EXPANSION JOINTS. PROVIDE
6. PROVIDE PVC SLEEVE 2" BIGGER IN DIAMETER THAN CONDUIT TO ACCOMMODATE CONSTRUCTION TOLERANCE.
CONNECT TO LOADS.
NATIONAL ELECTRIC MANUFACTURERS ASSOCIATES (NEMA) TC-2, UV-RESISTANT AND SCHEDULE 80. BEND CONDUITS AS NECESSARY TO
5. FURNISH AND INSTALL POLYVINYL CHLORIDE (PVC) CONDUIT IN CONFORMANCE WITH UL SECTION 651, NEC SECTION 347 AND THE
4. USE ONLY NEW, UNUSED AND UNDERWRITERS LABORATORIES (UL) LISTED EQUIPMENT AND MATERIALS FOR OUTDOOR USE.
INSTALLATION.
3. THE CONTRACTOR SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS, AND INCIDENTALS REQUIRED FOR A COMPLETE AND FUNCTIONAL
CONDUITS THROUGHOUT.
ORDINANCES. INSTALL GROUNDING IN ACCORDANCE WITH NEC ARTICLE 250. MAINTAIN SEPARATION BETWEEN 480V AND 120V CONDUCTORS/
2. ENSURE INSTALLATION MEETS ALL REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AND LOCAL
H. FEEDER SCHEDULE.
G. MINI POWER CENTER MOUNTING DETAILS IF REQUIRED.
F. MINI POWER CENTER DETAILS INCLUDING CIRCUIT BREAKER DETAILS.
E. SINGLE LINE DIAGRAM SHOWING MINI POWER CENTERS, SWITCHES, CONTACTORS, TIMERS, ETC.
D. FASTENER DETAILS FOR THE INTERIOR ELECTRICAL SYSTEM.
C. CONDUIT EXPANSION FITTING DETAILS.
B. CONDUIT ACCESS THROUGH BOX GIRDER END DIAPHRAGMS WITH MINIMUM I" CLEARANCE IN ALL DIRECTIONS.
CROSS FRAMES AS NECESSARY.
A. CONDUIT LAYOUT AND INSTALLATION DETAILS THROUGH DIAPHRAGMS, AROUND POST-TENSIONING (PT) DUCTS, LATERAL BRACING AND
LIGHTING SYSTEM FOR THE ENTIRE STRUCTURE. THE SHOP DRAWINGS MUST INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING ITEMS:
1. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD DETAILING THE LAYOUT OF THE MAINTENANCE
MPC
C
DC
ACCESS HATCH LID (OR ACCESS DOOR)
POWER SUPPLY TO MPC
480V DISCONNECT SWITCH FOR
CONTROL FOR MPC ACTIVATION
480V CONTACTOR WITH REMOTE SWITCH
HOUR RESET TIMERS6 CONTACTOR WITH
REMOTE SWITCHES FOR 480V
480V, 120/240V
7.5 KVA MINI POWER CENTER (MPC)
BOX, WATERPROOF BOX
MOUNTED IN NON-METALLIC OUTLET
CONFIGURATION 5-20R SURFACE WALL
120V DUPLEX RECEPTACLE, GFI, NEMA
CEILING MOUNTED LIGHTING FIXTURE
GIRDER
CONDUIT PVC SCHEDULE 80 IN BOX
S
S
AND ACCESS DOOR SWITCHES
CROSS SECTION SHOWING TYPICAL FOS
LIGHTING FIXTURE
CEILING MOUNTED
CONDUIT RACKACCESS HATCH LID
ACCESS HATCH SWITCH
3/4" CONDUIT
BOTTOM FLANGE
16" ABOVE
OUTLET BOX
NON-METALLIC
JUNCTION BOX
NON-METALLIC
S
S
1' -6"
FOS = FIXTURE OUTLET STATION
NOTE:
G-1
G-2
G-3
110'-2"
LANE
24'-0"
LANE
24'-0"
LANE
24'-0"
SHLDR.
20'-0"3'-1"
SHLDR.
12'-0"
S
BEGIN/END OF EACH MPC
SWITCH LOCATION AT THE
BOTTOM FLANGEBOTTOM FLANGE
TRANSVERSE STIFFENER
ATTACH SWITCH TO
BOTTOM FLANGE
16" ABOVE
OUTLET BOX
NON-METALLIC
STIFFENER
TRANSVERSE
� GIRDER 1 � BRIDGE � GIRDER 2
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-28 GENERAL NOTES AND DETAILMAINTENANCE LIGHTING
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
UNIT
*NO. CKT. STATIONWATTAGE
LUM.FINALNOTES
TOTAL
ITEM
*NO. CKT. STATIONWATTAGE
LUM.FINALNOTES
QUANTITIES ABOVE AND ANY INCIDENTALS NECESSARY FOR A COMPLETE AND ACCEPTED INSTALLATION.
PAY ITEM 715-50: THIS ITEM INCLUDES PAYMENT FOR ALL ITEMS LISTED IN TABULATION OF
IN THESE PLANS.
NECESSARY TO MAKE A COMPLETE AND OPERATIONAL FIXTURE OUTLET STATION (FOS) AS SPECIFIED
THE MPC CIRCUIT CONDUCTORS IN THE JUNCTION BOX, AND ANY OTHER EQUIPMENT OR MATERIALS
CONNECTING THESE 3 ITEMS, 3 #12 INSULATED CONDUCTORS FOR ELECTRICAL CONNECTION TO
MOUNTED JUNCTION BOX, DUPLEX RECEPTACLE WITH OUTLET BOX, 3/4" PVC SCHEDULE 80 CONDUIT
*** INCLUDES THE COST AND INSTALLATION OF THE CEILING MOUNTED LIGHT FIXTURE, WALL
AND OPERATIONAL MAINTENANCE LIGHTING SYSTEM AS SPECIFIED IN THESE PLANS.
AND REMOVE SWITCHES, 480 V DISCONNECT SWITCH, AND OTHER EQUIPMENT FOR A COMPLETE
** INCLUDES THE COST AND INSTALLATION OF THE 7.5 KVA MINI POWER CENTER, 480 CONTACTOR
LF
EA
LF
LF
LF
24
6
925
925
7,032
24
6
925
925
7,032
KELLY PARK RD. BRIDGE
L-30
FIXTURE OUTLET STATIONS (FOS) ***
MINI POWER CENTERS **
3/4" CONDUIT (F&I - IN BOX GIRDER)
1" CONDUIT (F&I - IN BOX GIRDER)
LIGHTING CONDUCTORS (F&I, NO. 10)
FOS #4
FOS #3
FOS #2
FOS #1
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
FOS #8
FOS #7
FOS #6
FOS #5
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B2 FIXTURE OUTLET STATION (FOS)
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B1 FIXTURE OUTLET STATION (FOS)
*NO. CKT. STATIONWATTAGE
LUM.FINALNOTES
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B3 FIXTURE OUTLET STATION (FOS)
FOS #12
FOS #11
FOS #10
FOS #9
*NO. CKT. STATIONWATTAGE
LUM.FINALNOTES *NO. CKT. STATION
WATTAGE
LUM.FINALNOTES
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B5 FIXTURE OUTLET STATION (FOS)
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B4 FIXTURE OUTLET STATION (FOS)
*NO. CKT. STATIONWATTAGE
LUM.FINALNOTES
1 & 2
1 & 2
1 & 2
1 & 2
314+06.60
313+56.60
313+06.60
312+56.60
100
100
100
100
FOR OUTLET RECEPTACLES.
CIRCUIT 1 IS FOR LIGHTING FIXTURES AND CIRCUIT 2 IS
* MINI POWER CENTER B6 FIXTURE OUTLET STATION (FOS)
FOS #16
FOS #15
FOS #14
FOS #13
FOS #20
FOS #19
FOS #18
FOS #17
FOS #24
FOS #23
FOS #22
FOS #21
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-29 DATAMAINTENANCE LIGHTING
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
WO
OD
OHD CABLE
WO
OD
WO
OD
WO
OD
WO
OD
310 311 312 313 314 315 316 317
82
83
84
85
86
5289
5290
5291
5292
5310 5311 5312
145
146
147
148
149
S
S
S
S
S
S
S
S
S
S
S
S
KE
LL
Y P
AR
K R
D
SR 429 NORTHBOUND
SR 429 SOUTHBOUND
50
Feet
0 10
N
FOS #5
FOS #6
STA. 312+52.63
BEGIN BRIDGE
50
Feet
0 10
N
STA. 314+10.63
BEGIN BRIDGE
TYP. FOS
CEILING MOUNTED LIGHTING FIXTUREEACH FOS HAS A RECEPTACLE AND A
SHEET FOR STATIONS AND CIRCUITS.SEE MAINTENANCE LIGHTING DATA
FOS= FIXTURE OUTLET STATION.
MP
C
C
C DC
¡ SR 429 (WEKIVA PKWY)
TYP. FOS
FOS #1
FOS #9
FOS #2
FOS #7
FOS #3
FOS #12
FOS #13
FOS #17
FOS #21
FOS #22
FOS #14
FOS #18
FOS #15
FOS #19
FOS #23
FOS #16
FOS #20
FOS #24
FOS #4
FOS #8
FOS #10
FOS #11
CKT #B-4 LOAD CENTER B
1-1" COND. TO 480V SERVICE PANEL
1- 1" COND. MPC CIRCUITS (3 #10)
1- 3/4" COND. REMOTE SWITCHES (3 #10)
2 CONDUITS
CKT #B-4 LOAD CENTER B
1-1" COND. TO 480V SERVICE PANEL
1- 1" COND. MPC CIRCUITS (3 #10)
1- 3/4" COND. REMOTE SWITCHES (3 #10)
2 CONDUITS
DC
S
SWITCH IS PLACED BY ACCESS HATCHWITH DISCONNECT AND CONTACTOR.B6: +/- STA. 314+31, 72' RT B5: +/- STA. 314+31, 52' RTB4: +/- STA. 314+31, 32' RTMINI POWER CENTERS
SWITCH IS PLACED BY ACCESS HATCHWITH DISCONNECT AND CONTACTOR.B3: +/- STA. 314+31, 72' LT B2: +/- STA. 314+31, 52' LTB1: +/- STA. 314+31, 32' LTMINI POWER CENTERS
MP
C
S
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-30 KELLY PARK RD. BRIDGEMAINTENANCE LIGHTING PLAN
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.
DC
MPC
C
S
1-#6 (G)
2-#6, B-4
1" CONDUIT
LOAD CENTER IN
*SERVICE FEED FROM
CKT-1
AT END OF
MPC
C
DC
S
POWER SUPPLY TO MPC
480V DISCONNECT SWITCH FOR
CONTROL FOR MPC ACTIVATION
480V CONTACTOR WITH REMOTE SWITCH
HOUR RESET TIMERS6 CONTACTOR WITH
REMOTE SWITCHES FOR 480V
480V, 120/240V
7.5 KVA MINI POWER CENTER (MPC)
BOX, WATERPROOF BOX
MOUNTED IN NON-METALLIC OUTLET
CONFIGURATION 5-20R SURFACE WALL
120V DUPLEX RECEPTACLE, GFI, NEMA
CEILING MOUNTED LIGHTING FIXTURE
CKT-1
CKT-2
ALL BOX GIRDERS: 2 #6 / 1 #6 GROUND FROM LOAD CENTER TO MINI POWER CENTERS.
6. SEE INDEX 21240 FOR FURTHER INFORMATION.
5. USE 1" CONDUIT AND #10 CONDUCTORS FOR ALL MPC CIRCUITS.
SHEET.
THE BOX GIRDERS. THESE SWITCHES ARE IN ADDITION TO THOSE SHOWN ON THIS
ADDITIONAL ACCESS HATCH LIDS WITH SWITCHES AT INTERMEDIATE POINTS WITHIN
CONNECTION TO THE SWITCH AT THE ACCESS HATCH LID. NOTE THERE ARE
4. EXTEND CIRCUIT FOR SWITCHES TO EACH END OF THE BOX GIRDERS TO PROVIDE
" CONDUIT AND #10 CONDUCTORS FOR REMOTE SWITCH CIRCUITS.433. USE
2. USE 1" CONDUIT FOR 480V SERVICE FEED TO MPC'S.
FOR LIGHTING FIXTURES. CIRCUIT 2 IS FOR OUTLET RECEPTACLE.
1. MINI POWER CENTER FIXTURE OUTLET STATION (FOS) CIRCUIT 1 IS
PROJECT NO.ROAD NO.
$USER$ $DATE$ $TIME$ $FILE$
NO.
SHEETDESCRIPTIONBYDATE
REVISIONS
DESCRIPTIONBYDATE
CFXSR 429 429-203
EXPRESSWAY AUTHORITYCENTRAL FLORIDA
L-31 ELECTRICAL SCHEMATICSMAINTENANCE LIGHTING
1-#10 (G)
2-#10, B-41-#10 (G)
2-#10, B-4
CERTIFICATE OF AUTHORIZATION NO. 3932
ORLAND0, FL 32801
LANDMARK CENTER TWO
225 E. ROBINSON ST., SUITE 300
VHB
P.E. LICENSE NUMBER 76215
AMBAR DIAZ-LOZANO, P.E.