Freeze Protection HAT/FP HAT/FP-B-E IC/FP-T FPP TABLE OF CONTENTS Scald Protection HAT/SP IC/SP-T I n-Line Temperature Control HAT HAT/RA HAT/RA-LP TV/HAT-RA TV/HAT-RA-LP VALVE ENGINE TV/HAT ECONO/HAT ECONO/HAT/RA Ambient / Surface Temperature Control TV/SC-A & TV/SC-AR TC/SC-AP TV/SC-I & TV/SC-IR ITCH Heather Assembly US/A 270k &US/A-R US/S-X & US/S-XR VC-1000 & VC-2000 Tempering and Diverting Therm-O-Mix Station Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R HAT/WWM & HAT/SWM ½ HAT/SWM Capacities Chart STVM Valve Therm-O-Mix Valve M/D VALVE 1” & 1¼” M/D Valve 1½” & 2” M/D Valve Miscellaneous EMPC ADV T-O-T Filtering System Thermal Actuator Engineering Data Application Profile #1 Application Profile #2 Application Profile #3 Application Profile #4 Application Profile #5 Application Profile #6 Application Profile #7 Application Questionnaire 353 Ivyland Road • Warminster, PA 18974-2205 • Phone: 215-674-9992 • 1-800-288-4878 • FAX: 215-674-8594 THERM-O-TECH, INC. ISO 9001 CERTIFIED www.thermomegatech.com

Upload: dangmien

Post on 30-Jul-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Freeze ProtectionHAT/FPHAT/FP-B-EIC/FP-TFPP

TABLE OF CONTENTS

Scald ProtectionHAT/SPIC/SP-T

In-Line Temperature ControlHATHAT/RAHAT/RA-LPTV/HAT-RATV/HAT-RA-LPVALVE ENGINETV/HATECONO/HATECONO/HAT/RA

Ambient / SurfaceTemperature Control

TV/SC-A & TV/SC-ARTC/SC-APTV/SC-I & TV/SC-IRITCH Heather AssemblyUS/A 270k &US/A-RUS/S-X & US/S-XRVC-1000 & VC-2000

Tempering and DivertingTherm-O-Mix StationTherm-O-Mix Station WWMTherm-O-Mix Station Mounting KitHAT/WWM-RHAT/WWM & HAT/SWM½ HAT/SWM Capacities ChartSTVM ValveTherm-O-Mix ValveM/D VALVE

1” & 1¼” M/D Valve1½” & 2” M/D Valve

MiscellaneousEMPCADVT-O-T Filtering SystemThermal Actuator

Engineering DataApplication Profile #1Application Profile #2Application Profile #3Application Profile #4Application Profile #5Application Profile #6Application Profile #7Application Questionnaire

353 Ivyland Road • Warminster, PA 18974-2205 • Phone: 215-674-9992 • 1-800-288-4878 • FAX: 215-674-8594

THERM-O-TECH, INC.ISO 9001

CERTIFIED

www.thermomegatech.com

Page 2: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

FreezeProtection

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 3: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL HAT/FPFREEZE PROTECTION VALVE

FREEZE PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:A thermostatic element senses ambient temperature

and if this falls below 40°F (4.4°C) the valve modulates

open allowing water to flow by the sensor. The valve

will remain open as long as the water flowing by the

sensor is less than 40°F (4.4°C). However, when the

water flowing by the sensor becomes greater than

40°F (4.4°C) the valve will close. The valve is fully

open at 35°F (2°C).

APPLICATIONS:HAT/FP (Freeze Protection) valves are ideal forprotection of piping, valves, fittings, pumps, condensatesystems, safety showers, fire lines, spray nozzles,freeze sensitive equipment, or as backup protectionon traced systems/equipment. The "AA" model isrecommended for draining condensate fromcompressed air systems.

ADVANTAGES:Typically freeze protection is effected by crackingopen manual bleed valves. This method is at bestrisky. Human error or plugging of partially crackedvalves annually accounts for large amounts of freezedamage to expensive equipment. HAT/FP valveseliminate this type of problem by automating freezeprotection, reducing water consumption, andeliminating damage and down time. The unique ram-type plug and seat provide reliable, tight shutoff longerthan any other design available. All HAT/FP valvesare 100% factory-tested and covered by a 36 monthprorated warranty.

DESIGN FEATURES:• Stainless steel body, fittings, spring and plug

• Corrosion resistant - Long service life

• Narrow temperature band

• Compact, low mass - Fast response

• Ram-type plug for reliable tight shutoff

• Downstream actuator for greater sensitivity

• Sensitive to temperature only

• Unaffected by pressure variations

• Easy installation with pipe wrench

HATFP.11/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 4: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERM-O-TECH INC353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

DIMENSIONS AND WEIGHTS

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

FREEZE PROTECTION VALVEMODEL HAT/FP

HEAT ACTUATED TRAP/FREEZE PROTECTION

PARTS AND MATERIALS

Phone: 215-674-9992 FAX: 215-674-8594CALL THE VALVE GURU TOLL FREE 1-800-288-GURU (4878)

TO ORDER, SPECIFY:Standard Model: 1/2 HAT/FP 035-C

or: 1/2 HAT/FP 035- Port Size: AA or C

or: 3/4 HAT/FP 035-D

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL2 INLET FITTING 303 STAINLESS STEEL

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 RAM-TYPE PLUG 303 STAINLESS STEEL

6 THERMAL ACTUATOR F.M. BRASS **

7 ACTUATOR CARRIER F.M. BRASS **

8 OUTLET FITTING 303 STAINLESS STEEL

9 SIZED ORIFICE* F.M. BRASS

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/2" 1.13 (29) 4.50 (114) .7 (.32)

3/4" 1.38 (35) 5.50 (140) 1.2 (.54)

MAX. OPER. PRESSURE

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED TEMP.

CV

3/4" NPT HAT Cv

` 300 PSIG21 BAR

200°F (93°C)

35°F (2°C)

40°F (4.4°C)

AA .05***

C .82

D 2.0

* AA Model only** All stainless steel version available. Consult factory.

*** "AA" Port recommended for compressed airsystems only. Discharges 0.5 CFM air at 150PSIG and 35°F. Use #20 mesh strainer with"AA" Port.

1/2" HAT/FP is available with AA & C ports.3/4" HAT/FP is available in D port only.

SPECIFICATIONS

HATFP.11/98

Visit us on the internet at: http://www.thermomegatech.com or E-Mail us at: [email protected]

INLET

1

3

5

7

8

2

4

6

9

D

OUTLET

L

Page 5: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL HAT/FP-B-EFREEZE PROTECTION VALVE FREEZE PROBLEMS?

CALL THE GURU 1-800-288-GURU

OPERATION:A thermostatic element senses fluid temperature and

if this falls below 35°F (1.7°C) the valve modulates

open allowing water to flow by the sensor. The valve

will remain open as long as the water flowing by the

sensor is less than 40°F (4.4°C). However, when the

water flowing by the sensor becomes greater than

40°F (4.4°C) the valve will close.

APPLICATIONS:HAT/FP-B-E valves are ideal for protection of piping,valves, fittings, pumps, condensate systems, safetyshowers, fire lines, spray nozzles, freeze sensitiveequipment, or as backup protection on traced systems/equipment.

ADVANTAGES:Typically freeze protection is effected by crackingopen manual bleed valves. This method is at bestrisky. Human error or plugging of partially crackedvalves annually accounts for large amounts of freezedamage to expensive equipment. HAT/FP-B-E valveseliminate this problem by automating freeze protection,reducing water consumption, and eliminating damageand down time. The unique ram-type plug and seatprovide reliable, tight shutoff longer than any otherdesign available. All HAT/FP-B-E valves are 100%factory-tested and covered by a 18 month proratedwarranty.

DESIGN FEATURES:• Stainless steel body, brass thermal element

• Corrosion resistant - Long service life

• Most narrow temperature band avalable

• Compact, low mass - Fast response

• Ram-type plug for reliable tight shutoff

• Sensitive to temperature only

• Unaffected by pressure variations

• Easy installation with pipe wrench

HATFP-BE1/03

• Field serviceable • Discharges the minimum amount of water required to prevent freeze damage

ISO 9001 CERTIFIED

THERM-OMEGA-TECH, INC. ISO 9001CERTIFIED

Page 6: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Model HAT/FP-B-EFREEZE PROTECTION VALVE

PARTS AND MATERIALS

ITEM DESCRIPTION MATERIAL

1 BODY 303 STAINLESS STEEL 2 O-RING EPDM

3 PLUG F. M. BRASS

4 SPRING 302 STAINLESS STEEL

5 THERMAL ACTUATOR F. M. BRASS

6 ENGINE BODY F. M. BRASS

7 O-RING EPDM

All Stainless Steel Version Available. Consult Factory.

STANDARD SPECIFICATIONS SIZE D L WEIGHT

in (mm) in (mm ) Lb (Kg) OPEN CLOSED

B 1.0 (25) 3.4 (87) .47(.21) 35ºF 40ºF .6 200 PSIG. (1.7ºC) (4.4ºC)

CV

1/2 HAT / FP - 35 -B -E

Thread size

Heat Actuated Trap

FreezeProtection

Full openset point

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Visit our internet site at: http://www.thermomegatech.com email: [email protected]

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)

Therm-Omega-Tech, Inc. reserves the right to changethe design and specifications without notice.

Valve Engine

Port Size

MaximumOperatingPressure

TO ORDER SPECIFY:

Page 7: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

FREEZE PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:

Under normal operating conditions, water passesthrough a virtually unobstructed 1" NPT-F or larger teebody, allowing this valve to be used in higher flowlines. When the fluid temperature approaches freezing,and freeze damage is imminent, the thermal actuatorlocated in the fluid stream modulates the valve open.When the makeup water temperature returns to thesafe range, the valve then modulates closed, reducingwaste water losses. Due to the actuator’s placementin the fluid stream, this valve is unaffected by ambientair temperature, and opens only when the water is indanger of freezing, being fully open at 35°F (2°C), andfully closed at 40°F (4.4°C).

MODEL IC/FP-TINTERCHANGEABLE CARTRIDGE/FREEZE PROTECTION

ICFPT.11/97

APPLICATIONS:IC/FP-T (Freeze Protection) valves are ideal for theprotection of piping, safety showers, condensatesystems, fire lines, spray nozzles, or as backupprotection on traced systems, where an unrestrictedflow is required under normal operating conditions. Itslack of sensitivity to air temperature makes this valveideal for applications where water conservation orwastewater disposal are a prime concern.

ADVANTAGES:Typically, freeze protection is effected by crackingopen manual bleed valves. This method is at bestrisky. Human error or plugging of partially crackedvalves annually accounts for millions of dollars infreeze damage. IC/FP-T valves eliminate this type ofproblem by automating protection, reducing waterconsumption, and eliminating damage and down time.The unique ram-type plug and seat provide reliable,tight shutoff longer than any other design available.The easily replaceable precalibrated cartridgesminimize downtime during maintenance. All IC valvesare 100% factory-tested and covered by an 18 monthprorated warranty.

DESIGN FEATURES:• Easily maintained• Pre-calibrated replacement cartridges available• Modulation throughout entire range to conserve

water• Corrosion resistant - Long service life• Narrowest temperature band available• Ram-type plug for reliable tight shutoff• Sensitive to fluid temperature only• Unaffected by pressure variations• Easy installation with pipe wrench

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 8: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

FREEZE PROTECTION VALVEMODEL IC/FP-T

INTERCHANGEABLE CARTRIDGE/FREEZE PROTECTION

ITEM DESCRIPTION MATERIAL

1 TEE BODY GALVANIZED STEEL2 CARTRIDGE BODY F. M. BRASS

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 RAM-TYPE PLUG 303 STAINLESS STEEL

6 THERMAL ACTUATOR F. M. BRASS

7 ACTUATOR BUSHING F. M. BRASS

8 CALIBRATION LOCKNUT STAINLESS STEEL

DIMENSIONS AND WEIGHTS

PARTS AND MATERIALS

SIZE A B X Y DRAIN WEIGHT("C") in (mm) in (mm) in (mm) in (mm) ("Z") Lb (Kg)

1" NPT-F 3.0 (76) 4.0 (102) 1.5 (38) 3.0 (76) 3/4" NPT-F 1.6 (.73)

1-1/4" NPT-F 3.2 (81) 4.2 (108) 1.5 (38) 3.0 (76) 3/4" NPT-F 1.6 (.73)

SPECIFICATIONSMAX. OPER. PRESS.

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED TEMP.

FLOW COEFFICIENTCV AT SETPOINT

150 PSIG10 BAR

200°F(93°C)35°F(2°C)40°F(4°C)

1.3

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications without

notice.

TEE SIZE (or 1" NPT)INTERCHANGEABLE CARTRIDGEFREEZE PROTECTIONFULL OPEN SET POINT IN F°TEE BODY (1" or 1-1/4" NPT)

or: 3/4 IC/FP 35 for Cartridge Only

TO ORDER, SPECIFY: 1- 1/4 IC / FP 35-T

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Visit our internet site at: http://www.thermomegatech.com

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

ICFPT.11/97

Page 9: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

FREEZE PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL FPPAUTOMATIC DRAIN PLUG

OPERATION:

The FPP may be though of as an automaticfreeze-out plug with one important difference:The stainless steel FPP cartridge releases itselffrom its body at a pre-set water temperature,rather than being forced out by the tremendouspressure of expanding ice. This provides almosta full one inch bore to rapidly drain a coolingsystem before damage can occur. Resetting andrearming the FPP prior to refilling the system iseasily accomplished by simply reheating thecartridge and utilizing the slotted actuator feature.With the unique built-in check valve (on Models Tand FL only), it's possible to replace the entire FPPwithout draining the system.

APPLICATIONS:

• Water cooled compressor heads• Exposed water lines• Tanks and related piping• Exposed chiller lines• Sump and reservoir protection

ADVANTAGES:

• Will not accidently trip or dump• Easy installation• Completely mechanical - No electrical or air

connections• Models T and FL can be maintained or

replaced without draining system• Cartridge can be reinstalled with simple

twist of wrist• Rapid draining• Easy system refill

DESIGN FEATURES:

• Senses only water temperatures• Long service life• Easy maintenance with interchangeable

cartridges• Several body styles available for various

applications: 1-1/4" NPT tee, flanged tee,and compressor head

• Release temperature of 47°F or 40°F

FPP.11/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 10: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

FPP.11/98

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

2.94 LATCHED

3.75

4.25

MIN. 2” CLEARANCE

CHECK VALVE

CLASS 300M.I. TEE

RE-INSTALLWITH THREADSEALANTHEX BODY

BAYONETSOCKET

SEAL

LANYARD

HIGH-STROKETHERMAL

ACTUATOR

LOCKING BALLS

PAINT MASK

COLOR-CODED CAP

DATE LABEL CARTRIDGE

MODEL S MODEL T

MODEL FL

MAY BE INSTALLEDAGAINST PLAIN OR GASKETED

FLANGES/FITTINGS

6.5”

4.50

3.75”

.687 DIA

MIN. 2” CLEARANCE

NOTE: 1 MODEL-CHPER COMPRESSOR HEAD

1-1/4 NPT-M

AUTOMATIC DRAIN PLUG VALVEMODEL FPP CONFIGURATIONS

MODEL CH

2.93

.375 DIA

2.625

(Specify release temperature of either 40°F (4.4°C) or 47°F (8.3°C))

The THERM-OMEGA-TECH FPP is available in the models shown.

SLOTTEDACTUATOR

Therm-Omega-Tech, Inc. reserves the right to change the design and specifications without notice.

Page 11: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ScaldProtection

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 12: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SCALD PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL HAT/SPFOR SCALD PROTECTION

HEAT ACTUATED TRAP/REVERSE ACTING

OPERATION:When the water temperature rises above safelimits, and a danger of scalding exists, the thermalactuator modulates the valve open. A small sampleof the water from the pipe system then flows pastthe sensor. If the water is above the acceptablerange, the valve will continue to modulate openuntil the overtemperature water is eliminated.When the makeup water temperature returns tothe safe range, the valve then modulates closed,reducing waste water losses. The HAT/SP opensonly when the water exceeds safe limits. TheHAT/SP-105 is full open at 105°F and remainsopen until water temperature is 95°F or below.The HAT/SP-115 is full open at 115°F and closedat 105°F and below.

APPLICATIONS:Solar radiation or overheating caused by steam orelectric tracing can cause extremely hightemperatures at the point of use, resulting in asafety hazard for plant personnel. When installed insafety showers, eyewash stations, and otherlocations exposed to the same source ofoverheating as the system, the HAT/SP will beheated just as the pipe system. The valve will opento establish flow until the overtemperature water iseliminated and it will then modulate closed.

ADVANTAGES:The HAT/SP valve continually senses andautomatically bleeds excessively hot water fromsafety shower/eyewash systems. Protection isprovided with minimal water consumption. Theunique plug and seat design offers the mostreliable, tight shutoff available. All HAT/SP valvesare 100% factory tested and covered by a 36month prorated warranty.

DESIGN FEATURES:• HAT/SP-105 meets OSHA temperature

guidelines• Stainless steel body, fittings, spring and

plug• Compact, low mass - Fast response• Corrosion resistant - Long service life• Most clog-resistant design available• Unaffected by pressure variations• Easy installation with pipe wrench• Installs in any orientation• Discharges the minimum amount of water

required to keep water temperature within safelimits

HATSP.5/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 13: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/2" 1.13 (29) 4.50 (114) 0.7 (.32)3/4" 1.38 (35) 5.50 (140) 1.2 (.54)

SCALD PROTECTION VALVEMODEL HAT/SP

HEAT ACTUATED TRAP/SCALD PROTECTION

HOW TO ORDER:

THERM-O-TECH INC.353 Ivyland Road

Warminster, PA 18974-2205

DIMENSIONS AND WEIGHTS

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

PARTS AND MATERIALS

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 INLET FITTING 303 STAINLESS STEEL

3 THERMAL ACTUATOR F.M. BRASS *

4 ACTUATOR CARRIER F.M. BRASS *

5 OPERATING SPRING STAINLESS STEEL

6 REVERSE PLUG 303 STAINLESS STEEL

7 SEAT SEAL PTFE

8 OUTLET FITTING 303 STAINLESS STEEL

* All stainless steel version available. Consult factory.

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

HATSP.5/99Visit us on the internet at: http://www.thermomegatech.com

MAX.OPER. PRESS.

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED TEMP.

1/2" NPT HAT Cv

3/4" NPT HAT Cv

150 PSIG(10.5 BAR)

200°F (93°C)

**Optional higher setpoint is available for areas whereambient temperatures normally exceed 95°F forextended periods

– For other cooling liquid applications ask for theHAT/RA and HAT/RA-LP product fact sheets.

STD OPT**105°F 115°F

(40.6°C) (46.1°C)95°F 105°F

(35.0°C) (40.6°C)

1.5 1.5

2.0 2.0Example: For a 1/2-inch valve thatopens at 105°F.

Specify: 1/2 HAT/SP - 105Size:

Full Open Temperature (°F):

Page 14: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SCALD PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL IC/SP-T

INTERCHANGEABLE CARTRIDGE/SCALD PROTECTION

OPERATION:Under normal operating conditions, water passesthrough a virtually unobstructed 1" or larger NPT tee,allowing this valve to be used in higher flow lines.When the water temperature rises above safe limits,and a danger of scalding exists, the thermal actuatorlocated in the fluid stream modulates the valve open.When the water temperature returns to the saferange, the valve then modulates closed, minimizingwater loss. Due to the actuator’s placement in the fluidstream this valve is unaffected by ambient airtemperature and is full open at 105°F(41°C) and willremain open until water temperature is 95°F(35°C) orbelow.

APPLICATIONS:Solar heating of piping systems can cause extremelyhigh temperatures at the point of use resulting in asafety hazard for plant personnel. When installed insafety showers, eyewash stations, and other sensitivelocations, the IC/SP-T (reverse acting) valve will opento establish flow until the overtemperature water iseliminated and then modulate closed.

ADVANTAGES:The IC/SP-T valve continually senses watertemperature and automatically bleeds excessivelyhot water from safety shower/eyewash systems.Protection is provided with minimal water consumption.The unique plug and seat design offers the mostreliable, tight shutoff available. The easily replaceableprecalibrated cartridge minimizes downtime duringmaintenance. All IC/SP-T valves are 100% factorytested and covered by an 18 month prorated warranty.

DESIGN FEATURES:• Temperature meets OSHA guidelines• Easily maintained• Pre-calibrated replacement cartridges available• Corrosion resistant - long service life• Most clog-resistant design available• Narrow temperature band• Modulation throughout range to conserve water,

yet will eliminate large quantities of overtemperaturewater when required

• Sensitive to fluid temperature only• Unaffected by pressure variations• Easily installed with pipe wrench

ICSPT.6/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 15: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

125 PSIG8.6 BAR

150°F ABOVESETPOINT

105°F 115°F(40.6°C) (46.1°C)

95°F 105°F(35.0°C) (40.6°C)

1.4

SCALD PROTECTION VALVEMODEL IC/SP-T

INTERCHANGEABLE CARTRIDGE/SCALD PROTECTION

353 IVYLAND ROADWARMINSTER, PA 18974-2205

THERM-OMEGA-TECH INC.

ICSPT.6/98

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS

SPECIFICATIONS

TEE SIZE (1-1/4" or 1" NPT-F)*INTERCHANGEABLE CARTRIDGESCALD PROTECTIONFULL OPEN SET POINT IN F°TEE BODY (1" or 1-1/4" NPT-F)

*or: 3/4 IC/SP-105 for Cartridge Only

TO ORDER, SPECIFY: 1- 1/4 IC / SP-105-T

Therm-0-Tech, Inc. reserves the right to changethe design and specifications without notice.

ITEM DESCRIPTION MATERIAL

1 TEE BODY GALVANIZED STEEL

2 CARTRIDGE BODY F. M. BRASS

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 PLUG HOLDER 303 STAINLESS STEEL

6 THERMAL ACTUATOR F. M. BRASS

7 ACTUATOR BUSHING F. M. BRASS

8 CALIBRATION LOCKNUT STAINLESS STEEL

SIZE A B X Y DRAIN WEIGHT("C") in (mm) in (mm) in (mm) in (mm) ("Z") Lb (Kg)

1" NPT-F 3.00 (76) 4.00 (102) 1.50 (38) 3.00 (76) 3/4" NPT-F 1.6 (.73)

1 1/4" NPT-F 3.19 (81) 4.25 (108) 1.50 (38) 3.00 (76) 3/4" NPT-F 1.6 (.73)

MAX. OPER. PRESS.

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED TEMP.

FLOW COEFFICIENTCV AT FULL OPEN

Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

Page 16: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

In-LineTemperature

Control

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 17: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRAP PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL HATHEAT ACTUATED TRAP

DESIGN FEATURES:

• Compact, low mass - Fast response• Corrosion resistant - Long service life• Stainless steel body, fittings, spring and plug• Ram-type plug for tight reliable shutoff• Eliminates live steam loss• Narrow temperature band• Downstream actuator for greater sensitivity• Orifice design limits live steam loss• Operating temperatures unaffected by

pressure• Wide choice of set points• Easy installation with pipe wrench

OPERATION:

The HAT valve responds only to temperature. Aftercondensate forms and cools to near the setpoint, theHAT valve modulates the flow to maintain a constantcondensate discharge temperature. HAT valves arewide open at start-up for rapid venting and initial heat-up. HAT valves are self-draining after shutdown, toeliminate freeze damage. Typical setpoints include105, 125, 180, 210, and 240°F (41, 52, 82, 99, 116°C).

APPLICATIONS:

Therm-O-Tech HAT (Heat Actuated Trap) valves areideal for replacing conventional steam traps onwinterization tracing, instrument tracing, condensatereturn system freeze protection, tracing for processesunder 150°F (65°C), and other applications requiringin-line flow control based on temperature.

ADVANTAGES:

Since HAT valves discharge condensate well belowsteam temperature, live steam losses are eliminated.For temperature sensitive applications, such asinstruments or certain processes, the reducedtemperature available for tracing simplifies operationsand eliminates overheating problems. The uniqueram-type plug & seat provide reliable, tight shut offlonger than any other design available. HAT valvesare 100% factory tested and are covered with ourstandard 36 month warranty & service policy to furtherreduce maintenance cost.

HAT.10/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 18: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

STEAM APPLICATION VALVEMODEL HAT

HEAT ACTUATED TRAP

SPECIFICATIONS

Standard Model: 1/2 HAT - 180 - A

or: 1/2 HAT - 180 - A Desired Full OpenSetpoint (°F) Port Size

or: 3/4 HAT - Desired Full Open Setpoint - D

TO ORDER, SPECIFY:

PARTS AND MATERIALS

Also available with tubing compression fittings(see TV/HAT Product Fact Sheet)

Also available in smaller size and 1/2 NPT-F(see SST Product Fact Sheet)

THERM-OMEGA-TECH, INC. reserves the right tochange the design and specifications without notice.

MAX. OPER. PRESS

TYPICALSETPOINT TEMPS.

(OTHER TEMPERATURES

AVAILABLE: 55°F - 240°F)

FLOW COEFFICIENTCV AT SETPOINT

3/4" NPT HAT CV

300 PSIG(20.7) BAR

105°F (41°C)

125°F (52°C)

180°F (82°C)

210°F (99°C)

240°F (116°C)

A 0.2 (STD)

B 0.8 (OPT)C 1.3 (OPT)

D 2.0 (STD)

OUTLET

INLET*

* Flow direction is reversed in valves over 210°F** All stainless steel version available. Consult factory.

HAT.10/98

DIMENSIONS AND WEIGHTSSIZE*** D L WEIGHT(NPT-F) in (mm) in (mm) Lb (Kg)

1/2" 1.13 (29) 4.50 (114) .70 (.31)

3/4" 1.38 (35) 5.50 (140) 1.20 (.54)

*** 3/8" NPT-F AVAILABLE AS SPECIAL ORDER

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

THERM-OMEGA-TECH INC.353 Ivyland Road

Warminster, PA USA 18974-2205

Visit our internet site at: http://www.thermomegatech.com

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 INLET FITTING 303 STAINLESS STEEL

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 RAM-TYPE PLUG 303 STAINLESS STEEL

6 THERMAL ACTUATOR F.M. BRASS **

7 ACTUATOR CARRIER F.M. BRASS **

8 OUTLET FITTING 303 STAINLESS STEEL

Page 19: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SCALD PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL HAT/RAHEAT ACTUATED TRAP/REVERSE ACTING

OPERATION:When a liquid temperature rises above desiredlimits, and a danger of overheating a processexists, the thermal actuator modulates the valveopen. A small sample of the liquid from thesystem then flows past the sensor. If the liquid isabove the acceptable range, the valve will continueto modulate open until the overtemperature liquidis eliminated. When the makeup liquidtemperature returns to the safe range, the valvethen modulates closed, reducing waste. TheHAT/RA opens only when the liquid exceeds thedesired limits.

APPLICATIONS:The model HAT/RA reverse acting valve can beused to regulate the flow of glycol, water or othermedia, in critical applications or to economicallyremove heat from equipment or a process.

ADVANTAGES:The HAT/RA valve continually senses liquidtemperature and provides a low cost, effectivemeans of accurate temperature control. Theunique plug and seat design offers the mostreliable, tight shutoff available. All HAT/RA valvesare 100% factory tested and covered by a 36month prorated warranty.

DESIGN FEATURES:• All stainless steel body, fittings, spring and

plug• Compact, low mass - Fast response• Corrosion resistant - Long service life• Most clog-resistant design available• Operates in narrow temperature band• Modulation throughout range to conserve

liquid media, yet will eliminate large quantitiesof over-temperature liquid if required

• Unaffected by pressure variations• Easy installation with pipe wrench• Operates in any orientation

HATRA.5/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 20: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/2" 1.13 (29) 4.50 (114) 0.7 (.32)3/4" 1.38 (35) 5.50 (140) 1.2 (.54)

MODEL HAT/RAHEAT ACTUATED TRAP/REVERSE ACTING

HOW TO ORDER:

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

DIMENSIONS AND WEIGHTS

Example: 1/2-inch valve full open at120°F with a 'C' port

Specify: 1/2 HAT/RA - 120 - CSizeFull open temp. (°F)Port size

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

PARTS AND MATERIALS

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 INLET FITTING 303 STAINLESS STEEL

3 THERMAL ACTUATOR F.M. BRASS *

4 ACTUATOR CARRIER F.M. BRASS *

5 OPERATING SPRING STAINLESS STEEL

6 REVERSE PLUG 303 STAINLESS STEEL

7 SEAT SEAL PTFE

8 OUTLET FITTING 303 STAINLESS STEEL

* All stainless steel version available. Consult factory.

Therm-O-Tech, Inc. reserves the right to change

the design and specifications without notice.

HATRA.5/99Visit us on the internet at: http://www.thermomegatech.com

FULL OPEN TEMP.

FULL CLOSED TEMP.

PORT SIZEFLOW COEFFICIENT

CV AT FULL OPEN

MAX. OPER. PRESS

ANY 10°F (5.5°C) INCRE-

MENT

40°F - 240°F (4.4°C - 116°C)

10°F (5.5°C)

BELOW FULL OPEN

B C D

1.1 (STD) 1.5 (OPT) 2.0 (STD)

150 100 50

1/2" HAT/RA is available with B or C ports.3/4" HAT/RA is available with D port only.

For scald protection in safety shower/eyewashsystems, ask for the HAT/SP product fact sheet.

2

7

5

3

1

8

4

6

L

D

OUTLET

INLET

Page 21: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL HAT/RA-LPFOR COOLING WATER CONTROLHEAT ACTUATED TRAP/REVERSE ACTINGWITH LEAKPORT

TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU

DESIGN FEATURES:• 100% factory tested

• Stainless steel body, fittings, spring and plug

• Compact, low mass, fast response

• Corrosion resistant, long service life

• Most clog resistant design available

• Narrow temperature band

• Modulation throughout temperature range

• Sensitive to fluid temperature only

• Unaffected by pressure variations

• Easy to install with pipe wrench

• Operates in any orientation

TYPICAL APPLICATIONS:Cooling water control for:

• Compressors• Engines• Heat Exchangers• Welding Equipment• Electrical Equipment• Molding Equipment

OPERATION:The HAT/RA-LP is installed on the cooling water outletof the equipment as an afterflow controller. At start-up, the valve is closed except for its control leakage,which allows a small flow so that the actuator insidethe valve can sense the changing equipmenttemperature. As the outlet water temperature increasesto within the operating range of the HAT/RA-LP , thethermal actuator modulates the valve open. If thecooling water temperature is above the acceptablerange, the valve will continue to modulate open allowingadditional coolant flow. As the outlet water temperaturefalls slightly, the valve then modulates toward the closedposition, reducing flow. This modulating actionmaintains a relatively constant outlet water temperatureeven as the cooling load changes.

ADVANTAGES:The HAT/RA-LP continually senses cooling water outlettemperature and automatically modulates to maintaindesired temperature. Optimum equipment temperatureimproves efficiency, reduces wear and conservescooling water. Therm-Omega-Tech valves aredesigned around our exclusive Thermoloid ® sensor/controller which is the most advanced and reliablethermal actuator of its type available today. All Therm-Omega-Tech valves are factory tested and calibratedto assure unsurpassed accuracy, reliability and quality.

HATRALP.5/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 22: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 INLET FITTING 303 STAINLESS STEEL

3 THERMAL ACTUATOR F.M. BRASS*

4 ACTUATOR CARRIER F.M. BRASS*

5 OPERATING SPRING STAINLESS STEEL

6 REVERSE PLUG 303 STAINLESS STEEL

7 OUTLET FITTING 303 STAINLESS STEEL

AFTERFLOW CONTROL VALVEMODEL HAT/RA-LP

HEAT ACTUATED TRAP/REVERSE ACTING WITH LEAKPORT

PARTS AND MATERIALS

* All stainless steel version available. Consult factory.

SPECIFICATIONSANY 10°F (5.5°C) INCREMENT

40°F to 240°F (4.4°C to 121.1°C)

10°F (5.5°C) BELOW FULL OPEN

B C D

1.1 (STD) 1.5 (OPT) 2.0 (STD)

150 100 50

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/2" 1.13 (29) 4.50 (114) 0.7 (.32)

3/4" 1.38 (35) 5.50 (140) 1.2 (.54)

Example: 1/2-inch valve full openat 120°F with a B port

Specify: 1/2 - HAT/RA - LP - 120 - BSizeFull open temp. (°F)Port size

Ask for HAT/RA product fact sheet if leakport not desired

HOW TO ORDER:

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

HATRALP.5/99

** Except for a control leakage of 1/4 GPM at 60 psigunless otherwise specified.

Also available without leakport. Seat seal available inmodels without leakport only. Consult factory.

Therm-Omega-Tech, Inc. reserves the right to change thedesign and specifications without notice.

INLET

OUTLET

DIMENSIONS AND WEIGHTS

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Visit us on the internet at: http://www.thermomegatech.com

FULL OPEN TEMP.

FULL CLOSED** TEMP.

PORT SIZE

FLOW COEFFICIENTCv AT FULL OPEN

MAX. OPER. PRESS.

Page 23: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL TV/HAT/RAHEAT ACTUATED TRAP/REVERSE ACTING

TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU

DESIGN FEATURES:• 100% Factory Tested

• Stainless Steel Body, Fittings, Spring and Plug

• Compact, Low Mass-Fast Response

• Corrosion Resistant - Long Service Life

• Most Clog - Resistant Design Available

• Narrow Temperature Band

• Modulation Throughout Temperature Range

• Sensitive To Fluid Temperature Only

• Unaffected By Pressure Variations

• Easy To Install

• Operates In Any Orientation

OPERATION:As the fluid temperature increases to within the

operating range of the TV/HAT/RA, the thermal actuator

modulates the valve open. If the fluid temperature is

above the acceptable range, the valve will continue to

modulate open allowing additional fluid discharge. As

the outlet temperature falls slightly, the valve then

modulates toward the closed position, reducing flow.

This modulating action maintains a relatively constant

fluid temperature even as operating conditions vary.

ADVANTAGES:The TV/HAT/RA continually senses fluid temperature

and automatically modulates to maintain desired

temperature. Optimum operating temperature

improves efficiency, reduces wear and conserves

energy. THERM-O-TECH valves are designed around

our exclusive Thermoloid ® sensor/controller which is

the most advanced and reliable thermal actuator of

its type available today. All THERM-O-TECH valves

are factory tested and calibrated to assure

unsurpassed accuracy, reliability and quality.

TYPICAL APPLICATIONS:The model TV/HAT/RA reverse acting valve can be

used to regulate the flow of glycol, water or other media

in critical applications or to economically remove heat

from equipment or a process.

TVHATRA.4/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 24: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

HEAT ACTUATED TRAP/REVERSE ACTINGMODEL TV/HAT/RA

HEAT ACTUATED TRAP/REVERSE ACTING

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONSMAX. OPER. PRESS.

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED* TEMP.

3/8" VALVE CV

1/2" VALVE CV

150 PSI(10 BAR)

240°F (115.6°C)

ANY 10°F INCREMENT40°F TO 210°F

10°F BELOWFULL OPEN

0.5

0.9

SIZE D L WEIGHT(Tube O.D.) in (mm) in (mm) Lb (Kg)

3/8" 1.0 (25) 3.6 (91) .33 (.15)

1/2" 1.0 (25) 3.8 (101) .35 (.16)

Example: 1/2-inch valve full open at 120°F

Specify: 1/2 - TV/HAT/RA - 120SizeFull open temp (°F)

HOW TO ORDER:

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

353 Ivyland RoadWarminster, PA 18974-2205

THERM-O-TECH INC.

TVHATRA.4/99

* All stainless steel version available. Consult factory.

ITEM DESCRIPTION MATERIAL

1 TUBING NUT STAINLESS STEEL2 DOUBLE FERRULES STAINLESS STEEL

3 SEAT END FITTING 303 STAINLESS STEEL

4 SEAT SEAL PTFE

5 OPERATING SPRING STAINLESS STEEL

6 RAM-TYPE PLUG 303 STAINLESS STEEL

7 LOCKNUT STAINLESS STEEL

8 THERMAL ACTUATOR BRASS*

9 BODY STAINLESS STEEL

Visit our internet site at: http://www.thermomegatech.com or E-mail us at: [email protected]

Therm-Omega-Tech, Inc. reserves

the right to change the design and

specifications without notice.

3

7

1

5

9

D

INLET

2

4

6

8

OUTLET

L

Page 25: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL TV/HAT/RA-LPFOR COOLING WATER CONTROLHEAT ACTUATED TRAP/REVERSE ACTINGWITH LEAKPORT

TEMPERATURE CONTROL PROBLEMS?

CALL THE GURU

1-800-288-GURU

DESIGN FEATURES:• 100% Factory Tested

• Stainless Steel Body, Fittings, Spring and Plug

• Compact, Low Mass-Fast Response

• Corrosion Resistant - Long Service Life

• Most Clog - Resistant Design Available

• Narrow Temperature Band

• Modulation Throughout Temperature Range

• Sensitive To Fluid Temperature Only

• Unaffected By Pressure Variations

• Easy To Install

• Operates In Any Orientation

OPERATION:The TV/HAT/RA-LP is installed on the cooling wateroutlet of the equipment as an afterflow controller. Atstart-up, the valve is closed except for the “controlleakage”, which allows a small amount of flow so thatthe actuator inside the valve can sense the changingequipment temperature. As the outlet watertemperature increases to within the operating rangeof the TV/HAT/RA-LP , the thermal actuator modulatesthe valve open. If the cooling water temperature isabove the acceptable range, the valve will continue tomodulate open allowing additional cooling flow. As theoutlet water temperature falls slightly, the valve thenmodulates toward the closed position, reducing flow.This modulating action maintains a relatively constantoutlet water temperature even as the cooling loadchanges.

ADVANTAGES:The TV/HAT/RA-LP continually senses cooling wateroutlet temperature and automatically modulates tomaintain desired temperature. Optimum equipmenttemperature improves efficiency, reduces wear andconserves cooling water. THERM-O-TECH valves aredesigned around our exclusive Thermoloid sensor/controller which is the most advanced and reliablethermal actuator of its type available today. All THERM-O-TECH valves are factory tested and calibrated toassure unsurpassed accuracy, reliability and quality.

TYPICAL APPLICATIONS:Cooling water control for:

• Compressors• Engines• Heat Exchangers• Welding Equipment• Electrical Equipment• Molding Equipment

TVHTRALP.5/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 26: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

AFTERFLOW CONTROL VALVEMODEL TV/HAT/RA-LP

HEAT ACTUATED TRAP/REVERSE ACTING

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONSMAX. OPER. PRESS.

MAX. OPER. TEMP.

FULL OPEN TEMP.

FULL CLOSED* TEMP.

3/8" Valve Cv

1/2" Valve Cv

150 PSI(10 BAR)

240°F (115.6°C)

ANY 10°F INCREMENT40°F TO 210°F

10°F BELOW

FULL OPEN

0.5

0.9

SIZE D L WEIGHT(Tube O.D.) in (mm) in (mm) Lb (Kg)

3/8" 1.0 (25) 3.6 (91) .33 (.15)

1/2" 1.0 (25) 3.8 (101) .35 (.16)

Example:

• For a 1/2-inch valve that opens at 120°F

Specify: 1/2 - TV/HAT/RA-LP - 120 Size Full open (°F)

(If no leakport desired request information on the TV/HAT/RA valve)

HOW TO ORDER:

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-O-TECH INC.

TVHTRALP.5/99

* Except for control leakage, 1/4 GPM at 60 psiunless otherwise specified. Also available withoutcontrol leakage.

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications without notice.

* All stainless steel version available. Consult factory.

ITEM DESCRIPTION MATERIAL

1 TUBING NUT STAINLESS STEEL2 DOUBLE FERRULES STAINLESS STEEL

3 SEAT END FITTING 303 STAINLESS STEEL

4 SEAT SEAL PTFE

5 OPERATING SPRING STAINLESS STEEL

6 RAM-TYPE PLUG 303 STAINLESS STEEL

7 LOCKNUT STAINLESS STEEL

8 THERMAL ACTUATOR BRASS*

9 BODY STAINLESS STEEL

Visit our internet site at: http://www.thermomegatech.com or E-mail us at: [email protected]

OUTLET

D

3

7

1

2

4

6

8

5

9

L

INLET

Page 27: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

VALVE ENGINETHERMALLY ACTUATED DEVICEFOR CUSTOM DESIGNS

CALL THE GURU 1-800-288-GURU

valveengine 5.01

OPERATIONThe Valve Engine responds only to temperaturechange, and is unaffected by operating pressure. Thevalve will proportionally vary flow rate with temperaturein a repeatable, precise manner.The ìValve Engineî is essentially a complete operatinginternal assembly for a self - operating temperatureactuated valve. The assembly includes everythingexcept the valve body. This compact, economicaldesign lends itself to simple integration into manykinds of equipment and devices.The heart of the engine is a solid-to-liquid phasechange thermal actuator. The actuator contains aThermoloidÆ compound which changes phase froma solid to a liquid as the temperature increases. Asthe phase change occurs, the volume of theThermoloidÆ material changes significantly, with theliquid volume greater than the solid volume. Since theThermoloidÆ is essentially incompressible undernormal operating loads and it is sealed into a rigidactuator housing, only a piston can move and extendas the volume increases.

This motion is used to open and close the valve.

ThermoloidÆ compounds are available in manytemperature ranges to cover most applications.

APPLICATIONSï Automatic thermostatic bypassï Thermostatic flow controlï Hydraulic bypassï Freeze protectionï High or low temperature reliefï Thermal relief valve for pumpsï High temperature safety shutoffï Thermostatic drain valveï Thermostatic cooling water controlï Thermostatic condensate drain

ADVANTAGESThe phase change and resultant motion occurs overa narrow temperature range. This property allowsprecise control of a device at a specific temperaturewith no significant effect outside the chosen controlrange. In fact, the properties of these thermostaticmaterials are so precise that are they used as primaryreference standards by ASTM for instrumentcalibration. Equally important, the reliability of theseactuators is very high, which has resulted in theirapplication in critical aerospace, military and manyindustrial applications.In addition to the actuator, the Valve Engine alsoincludes a stainless steel return spring, valve seat ando-ring plug. Seal materials and valve capacity can betailored to each application

DESIGN FEATURESï No outside power source is requiredï Rugged, compact designï Reliable and repeatable performanceï Wide choice of temperature rangesï Alternate contruction and seal materials availableï Extremely shock and vibration resistantï Can be used in pressure or vacuumï Custom mounting configurations availableï Compatable with most liquids, gases, or vaporsï Sold seperately or in a valve bodyï Also available in reverse acting (opens on rising temperature) Call factory for details.

ISO 9001CERTIFIED

Page 28: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ITEM DESCRIPTION MATERIAL

1 ENGINE BODY CDA - 360 2 O-RING EPDM 3 PLUG CDA - 360 4 ANTI-CHAFFING DISC PTFE 5 ACTUATOR GUIDE CDA - 360 6 ACTUATOR CUP CDA - 360

7 THERMOLOID MATERIAL PROPRIETARY COMPOUND

8 ACTUATOR PLUG SILICONE 9 ACTUATOR PISTON 303 STAINLESS STEEL

PARTS AND MATERIALS

VALVE ENGINETHERMALLY ACTUATED DEVICE

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Visit our internet site at: http://www.thermomegatech.com

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

STANDARD SPECIFICATIONS SIZE D L WEIGHT OPERATING

in (mm) in (mm ) Lb (Kg) TEMPERATURES

B .75 (19) 1.77 (45) .095(.043) .8

Therm-Omega-Tech, Inc. reserves the right to changethe design and specifications without notice.

FLOW COEFFICIENT

Cv @ SETPOINT

any 10∞increment

30∞ F to 240∞ F

TO ORDER SPECIFY:1/4 VE - 180 - B

Thread size

Valve Engine

Full opensetpoint

Size

Alternative construction and seal materials available

Wide choice of temperature changes

Page 29: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRAP PROBLEMS?CALL THE GURU1-800-288-GURU

TV/HAT

MODEL TV/HATTUBE VALVE - HEAT ACTUATED TRAP

APPLICATIONS:TV/HAT (Tube Valve/Heat Actuated Trap) valves areideal for use in conjunction with tracer tubing andtracing systems using pretraced tubing bundles.These versatile valves are compatible and are madeto be used in combination with the Therm-O-Tech TVseries valves as well as standard tubing and tubingfittings. Therm-O-Tech TV/HAT valves are ideal forreplacing conventional steam traps on winterizationtracing, instrument tracing, condensate return systemfreeze protection, tracing for processes under 150°F(65°C), and other applications requiring in-line flowcontrol based on temperature.

ADVANTAGES:These valves save space, eliminate the use of extra,expensive, and time consuming piping. They install inseconds. The unique ram-type plug & seat providereliable, tight shut off longer than any other designavailable. TV/HAT valves are 100% factory testedand are covered with our standard 36 month warranty& service policy to further reduce maintenance cost.Since TV/HAT valves discharge condensate wellbelow steam temperature, live steam losses areeliminated. For temperature sensitive applications,such as instruments or certain processes, the reducedtemperature available for tracing simplifies operationsand eliminates overheating problems.

DESIGN FEATURES:• Incredibly compact, low mass for fast response• Corrosion resistant - Long service life• Stainless steel body, fittings, spring and plug• Ram-type plug for tight reliable shutoff• Eliminates live steam losses• Operates in narrow temperature band• Downstream actuator for greater sensitivity• Operating temperatures unaffected by pressure• Wide choice of set points

OPERATION:The TV/HAT valve responds only to temperature.After condensate forms and cools to near the setpoint,the TV/HAT valve modulates the flow to maintain aconstant condensate discharge temperature. TV/HATvalves are wide open at start-up for rapid venting andinitial heat-up. TV/HAT valves are self-draining aftershutdown, to eliminate freeze damage. Typicalsetpoints are: 105, 125, 180, 210, 240°F (41, 52, 82,99 & 116°C). Other setpoints are available.

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 30: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TUBE O.D.TUBE VALVEHEAT ACTUATED TRAPFULL OPEN SET POINT (°F)

300 PSIG21 BAR

105, 125, 180,

210 & 240°F(41, 52, 82, 99

& 116°C)

0.5

SIZE D L WEIGHT(TUBE O.D.) in (mm) in (mm) Lb (Kg)

1/4" 1.0 (25) 3.4 (86) .30 (.14)3/8" 1.0 (25) 3.6 (91) .33 (.15)

1/2” 1.0 (25) 4.0 (102) .35 (.16)

STEAM APPLICATION VALVEMODEL TV/HAT

TUBE VALVE/HEAT ACTUATED TRAP

PARTS AND MATERIALS

* All stainless steel version available. Consult factory.

TO ORDER, SPECIFY:

DIMENSIONS AND WEIGHT SPECIFICATIONS

ITEM DESCRIPTION MATERIAL

1 TUBING NUT STAINLESS STEEL2 DOUBLE FERRULES STAINLESS STEEL

3 SEAT END FITTING 303 STAINLESS STEEL

4 SEAT SEAL PTFE

5 OPERATING SPRING STAINLESS STEEL

6 RAM-TYPE PLUG 303 STAINLESS STEEL

7 LOCKNUT STAINLESS STEEL

8 THERMAL ACTUATOR BRASS*

9 BODY STAINLESS STEELOUTLET

DDDDD

33333

77777

11111

INLET

22222

44444

66666

88888

55555

99999

MAX. OPER. PRESS.

STANDARDSETPOINT TEMPS.:

(OTHERS AVAILABLE)

CV

Available with NPT connections and largercapacities - See HAT and SST Bulletins

Available in reverse-acting model - Consult Factory

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-O-TECH INC.CALL THE VALVE GURU

TOLL FREE1-800-288-GURU (4878)

or 215-674-9992FAX: 215-674-8594

E-MAIL: [email protected]/98

3/8 TV / HAT 180

Visit us on the internet at: http://www.thermomegatech.com

LLLLL

Page 31: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRAP PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL ECONO/HATHEAT ACTUATED TRAP

APPLICATIONS:

Therm-O-Tech ECONO/HAT valves are ideal forreplacing conventional steam traps on winterizationtracing, instrument tracing, condensate return sys-tem freeze protection, tracing for processes under150oF, and other applications requiring in-line flowcontrol based on temperature.

ADVANTAGES:

These valves save space, eliminate the use of extra,expensive, and time consuming piping. They installin seconds. The unique ram-type plug & seat providereliable, tight shut off longer than any other designavailable. ECONO/HAT valves are 100% factorytested and are covered with our standard 18 monthwarranty & service policy to further reduce mainte-nance cost. Since ECONO/HAT valves dischargecondensate well below steam temperature, live steamlosses are eliminated. For temperature sensitiveapplications, such as instruments or certain proc-esses, the reduced temperature available for tracingsimplifies operations and eliminates overheating prob-lems.

DESIGN FEATURES:

• Incredibly compact, low mass - Fast response• Corrosion resistant - Long service life• All Brass body, stainless steel spring and plug• Ram-type plug for tight reliable shutoff• Eliminates live steam losses• Narrow temperature band• Downstream actuator for greater sensitivity• Operating temperatures unaffected by pressure• Wide choice of set points

OPERATION:

The ECONO/HAT valve responds only to temperature. Aftercondensate forms and cools to near the setpoint, theECONO/HAT valve modulates the flow to maintain a con-stant condensate discharge temperature. ECONO/HATvalves are wide open at start-up for rapid venting and initialheat-up. ECONO/HAT valves are self-draining after shut-down, to eliminate freeze damage. Typical setpoints (oF)include , 105, 125, 145, 155, 180, 210, 240.

ALSO AVAILABLE WITH F/F FITTINGS CONSULT FACTORY

ECONOHAT9.00

ISO 9001 CERTIFIED

Page 32: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TEMPERATURE ACTUATED VALVEMODEL ECONO/HAT

HEAT ACTUATED TRAP

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONSMAX. OPER. PRESS. 300 PSIG BAR.

105° 125°

180° 210°

240°

0.5

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/4" 1.00 (25.4) 3.50 (88.9) .35 (.16)

NPT SIZE

INLET THREAD

OUTLET THREAD

MODEL

HEAT ACTUATED TRAP

FULL OPEN SET POINT

TO ORDER SPECIFY:1/4 M/F ECONO/HAT-180

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-OMEGA-TECH INC.

ECONOHAT9.00

Valve will fully close 10 °F above setpoint temperature.

Also available with tubing compression fittings( see TV/HAT and TV/HAT/RA Bulletin )

Higher capacities and larger NPT sizes available( see HAT and HAT/RA Bulletin )

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications without notice.

ITEM DESCRIPTION MATERIAL

1 BODY BRASS, CDA 3602 THERMAL ACTUATOR BRASS, CDA 360

3 LOCKNUT 300 STAINLESS STEEL

4 BEARING PLATE 300 STAINLESS STEEL

5 OPERATING SPRING 302 STAINLESS STEEL

6 RAM - TYPE PLUG 303 STAINLESS STEEL

7 SEAT SEAL PTFE

8 INLET FITTING BRASS, CDA 360

Visit our internet site at: http://www.thermomegatech.com or E-mail us at: [email protected]

D

3

7

12

4

6

8

L

INLET

STANDARD SETPOINT TEMPS.:

( OTHERS AVAILABLE )

FLOW COEFFICIENT Cv AT SETPOINT

OUTLET

5

Page 33: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SCALD PROBLEMS?CALL THE GURU1-800-288-GURU

MODEL ECONO/HAT/RAHEAT ACTUATED TRAP/REVERSE ACTING

OPERATION:When a liquid temperature rises above desiredlimits, and a danger of overheating a processexists, the thermal actuator modulates the valveopen. A small sample of the liquid from the systemthen flows past the sensor. If the liquid is above theacceptable range, the valve will continue tomodulate open until the overtemperature liquid iseliminated. When the makeup liquid temperaturereturns to the safe range, the valve then modulatesclosed, reducing waste. The ECONO/HAT/RAopens only when the liquid exceeds the desiredlimits.

APPLICATIONS:The model ECONO/ HAT/RA reverse acting valvecan be used to regulate the flow of glycol, water orother media, in critical applications or toeconomically remove heat from equipment or aprocess.

ADVANTAGES:The ECONO/HAT/RA valve continually sensesliquid temperature and provides a low cost, effectivemeans of accurate temperature control. The uniqueplug and seat design offers the most reliable, tightshutoff available. All ECONO/HAT/RA valves are100% factory tested and covered by a 36 monthprorated warranty.

DESIGN FEATURES:• All brass body, fittings, stainless steel

spring and plug• Compact, low mass - Fast response• Corrosion resistant - Long service life• Most clog-resistant design available• Operates in narrow temperature band• Modulation throughout range to conserve

liquid media, yet will eliminate large quantitiesof over-temperature liquid if required

• Unaffected by pressure variations• Easy installation with pipe wrench• Operates in any orientation econohatra.00

ALSO AVAILABLE WITH M/F FITTINGS CONSULT FACTORY

ISO 9001 CERTIFIED

Page 34: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TEMPERATURE ACTUATED VALVEMODEL ECONO/HAT/RA

HEAT ACTUATED TRAP

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONSMAX. OPER. PRESS.

200 PSIG 13.8 BAR

105° 125°

180° 210°

0.5

SIZE D L WEIGHT(NPTF) in (mm) in (mm) Lb (Kg)

1/4" 1.00 (25.4) 3.50 (88.9) .35 (.16)

NPT SIZE

INLET THREAD

OUTLET THREAD

MODEL

HEAT ACTUATED TRAP

REVERSE ACTING

FULL OPEN SET POINT

TO ORDER SPECIFY: 1/4 M/F ECONO/HAT/RA-180

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail us at

[email protected]

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-OMEGA-TECH INC.

ECONOHATRA.9/00

Also available with tubing compression fittings( see TV/HAT/RA Bulletin )

Higher capacities and larger NPT sizes available( see HAT/RA Bulletin )

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications withoutnotice.

ITEM DESCRIPTION MATERIAL

1 BODY BRASS, CDA 3602 THERMAL ACTUATOR BRASS, CDA 360

3 LOCKNUT 300 STAINLESS STEEL

4 BEARING PLATE 300 STAINLESS STEEL

5 OPERATING SPRING 302 STAINLESS STEEL

6 RAM - TYPE PLUG 303 STAINLESS STEEL

7 SEAT SEAL PTFE

8 INLET FITTING BRASS, CDA 360

Visit our internet site at: http://www.thermomegatech.com

D

3

7

1

2

4

6

8

L

INLET

STANDARD (full open) SETPOINT TEMPS.:

( OTHERS AVAILABLE )

FLOW COEFFICIENT Cv AT SETPOINT

OUTLET

5

Page 35: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Ambient/SurfaceTemperature

Control

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 36: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRACING PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:At the designated set point, a thermostatic element locatedat one extreme of the valve (and thermally isolated from thebody of the device), will open or close completely within a10°F (5.6°C) differential (i.e. 35-45°F, etc.) and control theflow of steam, gas, or fluid through the valve based onambient temperature. The TV/SC-A opens on fallingtemperature; the TV/SC-AR opens on rising temperature.An optional solar shield (when used) allows the device to beinstalled where solar heating may affect the set point of thedevice. The TV/SC-A may also be used to control instrumentenclosure temperatures (see TV/SC-I and ITCH productfact sheets).

APPLICATIONS:There are literally hundreds of applications for thesecompact, self-contained, automatic control valves.Ambient sensing valves can be used to turn on steam, air,gas or liquids compatible with Teflon® and stainless steel,in response to ambient temperature change. Applicationsinclude automation of steam trace lines, operation ofpneumatically operated pumps for injection of antifreezeliquids, instrument enclosure control, etc. TV/SC-AR(reverse-acting) can be used to regulate the flow of glycol,water, or other cooling media or can automate coolingsprinklers, cooling baths, etc.

ADVANTAGES:At any chosen set point from 30°F (-1.1°C) to 170°F(77°C), these valves can economically automate a systemin response to ambient temperature. (For highertemperatures, consult factory.) Tubing connections allowquick installation at low cost. These valves reduce waste,lower maintenance cost, are economical to operate andsave space.

DESIGN FEATURES:• Large flow change on small temperature change (narrow temperature band)• Compact low mass - fast response• Ram-type plug for reliable shut off• Unaffected by pressure variations• Quick, easy installation• Compatible with standard tubing and connections• Long service life (36 month pro rated warranty)• Large flow coefficient (CV)• Direct acting (no pilot valve)• 100% factory tested

MODELS TV/SC-A & TV/SC-ARSTEAM CONTROL VALVE - AMBIENT SENSING

TVSCA.11/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 37: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

STEAM CONTROL VALVEMODEL TV/SC-A & TV/SC-AR

STEAM CONTROL VALVE - AMBIENT SENSING

TUBE O.D.TUBE VALVESTEAM CONTROLAMBIENT SENSING(REVERSE ACTING)FULL OPEN SET POINTSINGLE OUTLET (OR D=DOUBLE OUTLET)

STANDARD TEMPERATURES 30 - 170°F (-1.1 - 77°C)

THERM-O-TECH INC.

TO ORDER, SPECIFY:

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

TYPICAL INSTALLATION

PARTS AND MATERIALSITEM DESCRIPTION MATERIAL

1 THERMAL ACTUATOR 303 STAINLESS STEEL2 ISOLATION EXTENSION ACETAL COPOLYMER **3 SOLAR SHIELD (OPTIONAL) ACETAL COPOLYMER4 CALIBRATION LOCKNUT 303 STAINLESS STEEL5 YOKE 303 STAINLESS STEEL6 BODY 316 STAINLESS STEEL7 TUBING COMPRESSION NUT 316 STAINLESS STEEL

SPECIFICATIONSSIZE L M WEIGHT MAX.PRESS.

(TUBE O.D.) in (mm) in (mm) Lb (Kg) PSIG (BAR)

3/8" 7.38 (187) 1.19 (30) .45 (.20) 0.50 200 (13.8)

1/2" 7.88 (200) 1.38 (35) .75 (.34) 0.90 200 (13.8)

SIZE W WEIGHT(TUBE O.D.) in (mm) Lb (Kg)

3/8" 2.38 (60) .53 (.24)

1/2" 2.75 (70) .88 (.40)

DOUBLE OUTLET

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

Direct-acting valves are fully closedat 10°F above full open setpoint.

Reverse-acting valves are fully closedat 10°F below full open setpoint.

3/8 TV/SC-A (R) 035-S

Optional solar shield must be ordered separately.

** Stainless steel version available. Consult Factory.

TVSCA.11/98

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

SEE ITCH PRODUCT FACT SHEET FOR INSTRUMENT ENCLOSURE INSTALLATION

STEAM INLET

TV/HATTV/SC-A

TV/HAT

INSTALL WITHTHIS END DOWN

W

M

MOPTIONAL

OUTLET

7

5

64

2

13

OUTLET

* Temperature choice is dependent on freeze or set-uppoint of product. For higher temperatures, consult factory.

CV

Visit us on the internet at: http://www.thermomegatech.com

L

Page 38: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRACING PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:At the designated set point, a thermostatic element locatedat one extreme of the valve (and thermally isolated from thebody of the device), will open or close completely within a10°F (5.6°C) differential (i.e. 35-45°F, etc.) and control theflow of steam, gas, or fluid through the valve based onambient temperature. The TV/SC-AP opens on fallingtemperature. The TV/SC-AP may also be used to controlinstrument enclosure temperatures (see TV/SC-I and ITCHproduct fact sheets).

APPLICATIONS:There are literally hundreds of applications for thesecompact, self-contained, automatic control valves.Ambient sensing valves can be used to turn on steam, air,gas or liquids compatible with Teflon® and stainless steel,in response to ambient temperature change. Applicationsinclude automation of steam trace lines, operation ofpneumatically operated pumps for injection of antifreezeliquids, instrument enclosure control, etc.

ADVANTAGES:At any chosen set point from 30°F (-1.1°C) to 240°F(115°C), these valves can economically automate a systemin response to ambient temperature. (For highertemperatures, consult factory.) Tubing connections allowquick installation at low cost. These valves reduce waste,lower maintenance cost, are economical to operate andsave space.

DESIGN FEATURES:• Large flow change on small temperature change (narrow temperature band)• Compact low mass - fast response• Ram-type plug for reliable shut off• Unaffected by pressure variations• Quick, easy installation• Compatible with standard tubing and connections• Long service life (36 month pro rated warranty)• Large flow coefficient (CV)• Direct acting (no pilot valve)• 100% factory tested

MODELS TV/SC-APSTEAM CONTROL VALVE - AMBIENT SENSING

TVSCAP.8/01

ISO 9001 CERTIFIED

Page 39: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

STEAM CONTROL VALVEMODEL TV/SC-AP

STEAM CONTROL VALVE - AMBIENT SENSING

TUBE O.D.TUBE VALVESTEAM CONTROLAMBIENT SENSINGFULL OPEN SET POINTSINGLE OUTLET (OR D=DOUBLE OUTLET)STANDARD TEMPERATURES 30 - 240°F (-1.1 - 115°C)

THERM-O-TECH INC.

TO ORDER, SPECIFY:

353 IVYLAND ROADWARMINSTER, PA 18974-2205

TYPICAL INSTALLATION

PARTS AND MATERIALSITEM DESCRIPTION MATERIAL

1 THERMAL ACTUATOR 303 STAINLESS STEEL2 ISOLATION EXTENSION STAINLESS STEEL3 SOLAR SHIELD (OPTIONAL) ACETAL COPOLYMER4 CALIBRATION LOCKNUT 303 STAINLESS STEEL5 YOKE 303 STAINLESS STEEL6 BODY 316 STAINLESS STEEL7 TUBING COMPRESSION NUT 316 STAINLESS STEEL

SPECIFICATIONS SIZE L M WEIGHT MAX.PRESS.

(TUBE O.D.) in (mm) in (mm) Lb (Kg) PSIG (BAR)

3/8" 5.12 (130) 1.19 (30) .45 (.20) 0.50 200 (13.8)

1/2" 5.62 (133) 1.38 (35) .75 (.34) 0.90 200 (13.8)

SIZE W WEIGHT(TUBE O.D.) in (mm) Lb (Kg)

3/8" 2.38 (60) .53 (.24)

1/2" 2.75 (70) .88 (.40)

DOUBLE OUTLET

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

Direct-acting valves are fully closedat 10°F above full open setpoint.

3/8 TV/SC-AP 035-S

TVSCAP.8/01

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

SEE ITCH PRODUCT FACT SHEET FOR INSTRUMENT ENCLOSURE INSTALLATION

STEAM INLET

TV/HATTV/SC-A

TV/HAT

INSTALL WITHTHIS END DOWN

W

M

MOPTIONALOUTLET

7

5

64

2

13

OUTLET

* Temperature choice is dependent on freeze or set-uppoint of product. For higher temperatures, consult factory.

CV

Visit us on the internet at: http://www.thermomegatech.com

L

Page 40: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

OPERATION:At the designated control point, a thermostaticelement located at one extreme of the TV/SC-I(inside the enclosure) regulates the steam supply tothe heater to accurately maintain the desiredtemperature, operating like the thermostat in anoven. Heat radiating from the steam coil heaterreaches the actuator causing it to quickly shut off thesteam supply when the desired temperature isreached, regardless of outside ambient. In coolingapplications, the TV/SC-IR opens on risingtemperature to regulate the flow of cooling media tothe enclosure. The TV/SC-I comes complete with aweather-tight bulkhead fitting for the valve body;optional bulkhead fittings for 3/8 tubing connectionsare available. Also available is a short configurationfor installations with the valve and all connectionscompletely within the enclosure (see TV/SC-A andITCH product fact sheets). These economical valvesare available with set points from 40°F to 210°F(4.4°C to 98.9°C).

APPLICATIONS:The Therm-O-Tech TV/SC-I assures accuratetemperature control in an instrument or analyzerenclosure. It’s a reliable, economical alternative tocostly, hazardous electric heating. This self-contained compact thermostatic control valve sensesenclosure temperature and automatically regulatesthe flow of steam to maintain the temperature. Incooling applications the reverse-acting TV/SC-IRcan be used to regulate the flow of glycol, water, airor other cooling media.

ADVANTAGES:TV/SC-I valves will maintain enclosure temperatureaccurately over a wide range of ambient temperatureswith steam supply pressures from 15 psig to 200psig (1.0 to 13.8 BAR) without danger of overheatingdelicate instruments. No special NEMA-7 or -9housings are required even in potentially explosiveenvironments.

DESIGN FEATURES:• Eliminates danger of overheating• 100% factory tested• Direct acting (No pilot valve)• Maintains enclosure temperature within specified

range• Eliminates explosion hazard• All Stainless Steel body, fittings, spring & plug• Ram-type plug for reliable tight shut-off• Unaffected by pressure• Long service life (36 month pro rated warranty)• Compatible with standard tubing and connections• Quick easy installation

TV/HATSTEAM TRAP

TV/SC-I

TV/HATSTEAM TRAP

STEAMSUPPLY

OPTIONALCONNECTIONFOR TRACING

IMPULSELINES

STEAMHEATER

MODELS TV/SC-I & TV/SC-IRINSTRUMENT ENCLOSURE TEMPERATURE CONTROL

HEATER PROBLEMS?CALL THE GURU1-800-288-GURU

TVSCI.4/99

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 41: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

INSTRUMENT ENCLOSURE VALVEMODELS TV/SC-I & TV/SC-IR

TUBE VALVE/STEAM CONTROL-INSTRUMENT ENCLOSURE

THERM-O-TECH INC.

ITEM DESCRIPTION MATERIAL

1 THERMAL ACTUATOR 303 STAINLESS STEEL2 ISOLATION EXTENSION ACETAL COPOLYMER **3 VALVE MOUNTING BULKHEAD FITTING ACETAL COPOLYMER4 CALIBRATION LOCKNUT 303 STAINLESS STEEL5 YOKE 303 STAINLESS STEEL6 BODY 316 STAINLESS STEEL7 TUBING COMPRESSION NUT 316 STAINLESS STEEL8 3/8 TUBING BULKHEAD FITTINGS (OPTIONAL) ACETAL COPOLYMER

PARTS AND MATERIALS

MAX. OPER. PRESS. 200 PSIG (13.8 BAR)

AVAILABLECONTROL POINT*

TEMPS. (°F):3/8” VALVE Cv

1/2” VALVE Cv

DIMENSIONS AND WEIGHTS DOUBLE OUTLET

SPECIFICATIONS

SIZE L M X WEIGHT(TUBE O.D.) in (mm) in (mm) in (mm) Lb (Kg)

3/8" 10.0 (254) 1.2 (30) 5.2 (132) .72 (.33)

1/2” 10.5 (267) 1.38 (35) 5.2 (132) 1.2 (.54)

W WEIGHTin (mm) Lb (Kg)

2.4 (61) .80 (.36)

2.8 (71) .83 (.38)

TO ORDER, SPECIFY:

TUBE O.D.TUBE VALVESTEAM CONTROL-INSTRUMENT(REVERSE ACTING)FULL OPEN SET POINT * (°F)SINGLE OUTLET (or D = Double Outlet)

3/8 TV/SC-I (R) 100 - S

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)or 215-674-9992

FAX: 215-674-8594E-MAIL: [email protected]

** Stainless steel version available. Consult Factory.

LLLLL

OPTIONAL DOUBLE OUTLET

X (MAX.)

1.25

OUTLETMMMMM

M

INLETINLETINLETINLETINLETW

.75

Therm-Omega-Tech, Inc. reserves the right to changethe design and specifications without notice.

* Select valve setpoint 10° above desired control temperature.

Direct-acting valves are full closed at 10°F (5.6°C) abovefull open set point.Reverse-acting valves are full closed at 10° (5.6°C)below full open set point.

Optional bulkhead fittings must be ordered seperately.

40° - 210°F

4.4° - 98.9°C

0.5

0.9

353 IVYLAND ROADWARMINSTER, PA 18974-2205

Visit us on the internet at: http://www.thermomegatech.com

Page 42: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

HEATER PROBLEMS?

CALL THE GURU

1-800-288-GURU

ITCH HEATER ASSEMBLYINSTRUMENTATION THERMOSTATICALLY

CONTROLLED HEATER ASSEMBLY

OPERATION:At the designated control point, a thermostatic elementlocated at one extreme of the TV/SC-A valve portion of theITCH Heater Assembly regulates the steam supply to theheater coil to accurately maintain the desired temperature,operating like the thermostat in an oven. The TV/HAT at thevalve inlet keeps the steam supply hot, right up to the valve.Heat radiating from the steam coil heater reaches theactuator causing it to quickly close the steam supply whenthe desired temperature is reached, regardless of ambient.In cooling applications, the TV/SC-AR opens on risingtemperature to regulate the flow of cooling media to theenclosere. The TV/HAT at the outlet of the steam coilregulates outflow based on the condensate temperature, formaximum economy. The ITCH Heater Assembly comescomplete with steam coil, mounting bracket, and TV/SC-Avalve assembly, two TV/HAT valves, and two weather-tightbulkhead fittings for 3/8 tubing connections. TV/SC-A andTV/SC-I valves (with external connections) are also availableseparately.

APPLICATIONS:The Therm-O-Tech ITCH Heater Assembly assuresextremely accurate temperature control in an instrumentor analyzer enclosure. This self-contained unit providesa reliable, economical alternative to costly, hazardouselectric heating. The compact thermostatic control valvesenses enclosure temperature and automaticallyregulates the flow of steam to to the steam coil tomaintain the desired temperature to within 2°F (1.1°C) ofthe desired control point. In applications where theenclosure needs to be cooled, a reverse-acting ITCH/RA can be used to regulate the flow of glycol, water, orother cooling media. These economical valves areavailable with set points from 40°F to 210°F (4.4°C to98.9°C).

ADVANTAGES:ITCH Heater Assemblies will maintain enclosuretemperature accurately over a wide range of ambienttemperatures with steam supply pressures from 15 psigto 200 psig (1.0 to 13.8 BAR) without danger of overheatingdelicate instruments. No special NEMA-7 or -9 housingsare required even in potentially explosive environments.Enclosure temperatures can be maintained within 2°F(1.1°C) for pennies a day.

DESIGN FEATURES:• Complete kit provides quick, easy installation• Eliminates danger of overheating• 100% factory tested• Direct acting (No pilot valve)• Maintains enclosure temperature within 2°F (1.1°C) of control point• Eliminates explosion hazard• All stainless steel body, fittings, spring & plug• Ram-type plug for reliable tight shutoff• Unaffected by pressure• Long service life (36 month pro rated warranty)• Compatible with standard tubing and tubing connections

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 43: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ITCH HEATER ASSEMBLYINSTRUMENTATION THERMOSTATICALLY CONTROLLED HEATER

Specify TV/SC-A setpoint only. TV/HATtemperatures are selected by factory.

TUBE O.D.ITCH HEATER(REVERSE ACTING)FULL OPEN SET POINT * (°F)

3/8 ITCH (/RA) 100

SPECIFICATIONSTO ORDER, SPECIFY:

ITEM DESCRIPTION MATERIAL

1 TV/SC-A VALVE SEE CATALOG PAGE

2 STEAM COIL STAINLESS STEEL

3 MOUNTING BRACKET STAINLESS STEEL

4 BULKHEAD FITTING ACETAL COPOLYMER

5 TV/HAT SEE CATALOG PAGE

SIZE A B C D W X Y (NOM.) Z (MIN.)(TUBE O.D.) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm)

3/8" 3.8 (97) 3.5 (89) 3.8 (97) 1.5 (38) 8.0 (203) 4.0 (102) 9.0 (229) 1.5 (38)

MAX. OPER. PRESS. 200 PSIG (13.8 BAR)

AVAILABLECONTROL POINT*

TEMPS.FLOW COEFFICIENT

CV AT SETPOINT 0.50

DIMENSIONS

PARTS AND MATERIALS

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

ITCH.9/98

* Select valve setpoint 10° above desired controltemperature.

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

THERM-O-TECH INC.353 Ivyland Road

Warminster, PA 18974-2205

MOUNTINGDIMENSIONS

40° - 210° F

4.4° - 98.9°C

Visit us on the internet at: http://www.thermomegatech.com or E-Mail us at: [email protected]

Page 44: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRACING PROBLEMS?TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU (4878)

OPERATION:At the designated set point, a thermostatic element locatedat one extreme of the valve (and thermally isolated from thebody of the device), will open or close completely over a 10°F(5.5°C) differential (i.e. 35-45°F, 90-100°F, etc.) and controlthe flow of steam, gas, or fluid through the valve based onambient temperature. The model US/A 270k typically willhandle up to 400' of 1/2" tracer (two 200' runs using thedouble outlet model) while providing up to approximately270,000 BTU/hr. at 100 PSIG steam pressure. A solar shield(when used) allows the device to be installed where solarheating may affect the set point of the device.

* Models: 1/2" - 270k, 1/2" - 350k, 3/4" - 410k Max. Capacities: k = kBTU @ 100 PSIG Steam

MODELS: US/A 270k*& US/A-R

ULTRA SENSE/AMBIENT SENSINGTEMPERATURE CONTROL VALVE

APPLICATIONS:

ADVANTAGES:At any chosen set point from 30°F (-1°C) to 140°F (60°C),these valves can economically automate a system inresponse to ambient temperature.

Reduce waste, lower maintenance, reduce cost,save space.

DESIGN FEATURES:• Lightweight, all stainless steel components• No castings - All welded construction• Large flow change on small temperature change• Compact low mass - fast response• Ram-type plug for reliable shut off• Unaffected by pressure variations• Quick, easy installation• Long service life (36 month pro rated warranty)• Direct acting (no pilot valve)• 100% factory tested• Single or double outlet• Three different capacities available• Special connections available on request• Special temperatures available

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 45: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SPECIFICATIONSSIZE L A C WEIGHT STEAM MAX. PRESS.

(NPT-F) in (mm) in (mm) in (mm) Lb (Kg) CAPACITY PSIG (BAR)(kBTU/Hr)

1/2" 11.3 (287) 1.7 (43) 1.5 (38) 1.50 (.68) 1.3 270 200 (13.8)

1/2" HI-CAP. 11.3 (287) 1.7 (43) 1.5 (38) 1.50 (.68) 1.7 350 200 (13.8)

3/4" 11.5 (292) 1.8 (46) 1.8 (46) 1.76 (.80) 2.0 410 200 (13.8)

PARTS AND MATERIALS

TEMPERATURE CONTROL VALVEMODEL US/A & US/A-R

ULTRA SENSE/ AMBIENT SENSING

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

TO ORDER, SPECIFY:

NPT SizeUltra SenseAmbient SensingDirect Acting or Reverse ActingCapacity (270k, 350k, 410k)Control Point (30oF and up)Single Outlet (S) (or (D) Double Outlet)

TYPICAL APPLICATIONS

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

1/2 US/A-R 270k 035-S

(OPTIONAL)

Optional solar shield must be ordered separately.

353 Ivyland Road

Warminster, PA 18974-2205

INLET

OUTLET

ITEM DESCRIPTION MATERIAL

BODY STAINLESS STEEL

OUTLET FITTING STAINLESS STEELOUTLET FITTING (OPTIONAL) STAINLESS STEELYOKE STAINLESS STEELCALIBRATION LOCKNUT STAINLESS STEELISOLATION EXTENSION ACETAL COPOLYMER

THERMAL ACTUATOR STAINLESS STEELSOLAR SHIELD (OPTIONAL) ACETAL COPOLYMER

COOLING MEDIA

COOLINGSPRAY

US/A-RCOOLINGSPRAY

STEAM

TV/HATOR HAT US/A

SIZE W WEIGHT(NPT-F) in (mm) Lb (Kg)

1/2" 3.4 (86) 1.58 (.72)

3/4" 3.6 (91) 1.90 (.86)

DOUBLE OUTLET

THERM-O-TECH INC.

USA.10/98

CV

Visit us on the internet at: http://www.thermomegatech.com or E-Mail us at: [email protected]

Page 46: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TRACING PROBLEMS?TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:The US/S-X and US/S-XR valves Thermoloid ® sensor/controller element may be placed against the process lineor pipe with the optional weld-o-let or band-o-let, or in theline with the integral 3/4 NPT-M bushing. This allows thetemperature element to be in contact with the process tocontrol the valve section and regulate the inflow of heatingmedia (or cooling media with the US/S-XR). Inputtemperatures or steam supply can vary widely, but thecontrol temperature is maintained within desired limits.

APPLICATIONS:These compact self contained control valves canmaintain very tight temperature control of any numberof control loops using steam, liquid phase heat transfermedia such as Dowtherm®, hot water, hot oil, etc. Ingeneral they can be used whenever accurate but lowcost control is required. The reverse acting model,US/S-XR can be used to control cooling media toeconomically remove heat from equipment or aprocess.

ADVANTAGES:Models US/S-X and US/S-XR provide a low cost,effective means of accurate temperature controlregardless of available steam pressure or availableheating/cooling media temperature. NPT threadedconnections offer unlimited piping variations andlarge flow capacity. The US/S-X and US/S-XR valvesneed no user adjustment and can be installed inminutes, saving time and money in an unlimitednumber of control applications.

DESIGN FEATURES:• All stainless steel & welded construction• Narrow temperature band• Compact low mass - fast response• Ram-type plug for reliable shut off• Unaffected by pressure variations• Quick, easy installation• NPT threaded connections• Long service life• Direct acting (no pilot valve)• 100% factory tested• Thermoloid ® sensor/controller

MODELS US/S-X & US/S-XRULTRA SENSE SURFACE SENSINGDIRECT OR REVERSE ACTINGTEMPERATURE CONTROL VALVE

BULLETIN USSX.1/98

(Valves shown with optional band-o-let and installed in pipe tee)

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 47: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ITEM DESCRIPTION MATERIAL

1 BODY STAINLESS STEEL2 OUTLET FITTING STAINLESS STEEL3 OUTLET FITTING (OPTIONAL) STAINLESS STEEL4 ISOLATION SECTION STAINLESS STEEL5 YOKE STAINLESS STEEL6 BUSHING SEALS BUNA-N (STANDARD)7 3/4" NPT-M BUSHING STAINLESS STEEL8 THERMAL ACTUATOR STAINLESS STEEL9 ATTACHMENT FITTING * STAINLESS STEEL

NPT sizeUltra SenseSurface SensingDirect or ReverseSet point temperature in °F*Single Outlet (or D=Double Outlet)

*Available set points: 30 - 240°F(-1 - 116°C)

If desired, optional weld-o-let or band-o-let must be specified.

TEMPERATURE CONTROL VALVEMODEL US/S-X & US/S-XR

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)or 215-674-9992

FAX: 215-674-8594E-MAIL: [email protected]

BULLETIN USSX.1/98

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications without notice.

ULTRA SENSE SURFACE SENSING DIRECT OR REVERSE

DOUBLE OUTLET

PARTS AND MATERIALS

* Optional attachment fitting may be specified aseither a weld-o-let or a band-o-let type fitting.

TO ORDER, SPECIFY: 1/2 US/S-XR-150-S

SPECIFICATIONSSIZE L A C WEIGHT CV MAX. PRESS.

(NPT-F) in (mm) in (mm) in (mm) Lb (Kg) DIRECT PSI (BAR)

1/2" 7.9 (201) 1.7 (43) 1.5 (38) 1.16 (.53) 1.3 200 (13.8)3/4" 8.7 (221) 1.8 (46) 1.8 (46) 1.42 (.64) 2.0 200 (13.8)

SIZE W WEIGHT(NPT-F) in (mm) Lb (Kg)

1/2" 3.4 (86) 1.30 (.59)

3/4" 3.6 (91) 1.58 (.72)

Visit us on the internet at: http://www.thermomegatech.com

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974

Page 48: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATIONS:The THERM-O-TECH Enclosure Air ConditioningSystem will keep process equipment from overheatingand going out of calibration or worse yet, going out ofservice. This self-contained unit provides a reliable,economic alternative to costly, hazardous electriccooling such as muffin fans or air conditioning systems.It does not require a special NEMA-7 or -9 enclosureeven in potentially explosive environments. Combinedwith the optional control valve, enclosure temperaturescan be maintained within 2°F (1.1°C) for pennies a day.The Enclosure Air Conditioning System is installedon a typical plant air supply. The vortex device coolsthe air entering the chamber while venting the warmerair to the atmosphere. The sensor and control valvecombination keeps the temperature in the desired presetrange.

ADVANTAGES:• Prevents malfunctioning of critical process

equipment due to overheating. (1000 Btuh at100 PSIG, 2000 Btuh at 100 PSIG)

• No need for expensive and elaborateexplosion-proof cooling devices - uses plant air.

• Low operating costs.• Long service life.• Easy to install and maintain.

DESIGN FEATURES:• Lightweight, durable components.• Can be tailored to users specific requirements.• Uses typical plant air supply.• Typically reduces inlet air temperature by 60°F (33.3°C).• Will maintain enclosure temperature at a

predetermined level.• The VC-1000 consists of a single vortex cooler and

exhaust flow controller connected with 3 ft. ofheavy duty hose. The VC-2000 is a combination oftwo vortex coolers with two exhaust flowcontroller’s. Choice depends on cooling needs.

MODELS: VC 1000 & VC 2000ENCLOSURE AIR CONDITIONING SYSTEM

TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:The Enclosure Air Conditioning System is connectedto a typical plant air supply. The vortex device cools theair entering the enclosure, venting the warmer air intothe atmosphere. The combination of the vortex coolerand the optional control valve maintains the temperaturein the enclosure within a preset range.

VC1000.2/98

EXHAUST MAY EXITTHROUGH TOP SIDE OR

BOTTOM OF ENCLOSURE

SENSOR &CONTROL VALVE

VORTEXCOOLER

VC 2000 ILLUSTRATED(Solid piping not included - used

for illustration purposes only)

EXHAUSTFLOW

CONTROLLER

AIR INLET

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 49: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

ITEM DESCRIPTION MATERIAL

1 MUFFLER HOUSING BRASS

2 INLET BODY BRASS

3 OUTLET FITTING BRASS

4 NOZZLE BRASS

5 MUFFLER/DIFFUSER BRASS

6 SPACER ACETAL COPOLYMER

7 GENERATOR ACETAL COPOLYMER

8 SPRING STAINLESS STEEL

9 EXHAUST INLET BRASS

10 EXHAUST ADJUSTMENT BRASS

11 O-RING VITON

VC1000.2/98

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974

Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

MODEL VC 1000Line Drawings

VC-1000

MPC-1

1.63”

3.15”

.70”

3/8”ID HOSE BARB1.00”

1.15”

1/4” NPT

SPECIFICATIONS INLET AT 100 PSIG/70°F(6.9 BAR/21°C)

CAPACITY 1000 Btuh (252 KCAL/H)

AIR CONSUMPTION 30 SCFM (850 SLPM)

WEIGHT 0.8 LBS (0.36 kg)

VC-1000

7

3

1

2

6

58

4

10

11

9

3/8”ID HOSE BIB

3.00

.63

Page 50: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Tempering&

Diverting

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 51: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERM-O-MIX® STATIONALL WEATHER INSTANT

TEMPERED WATER SUPPLY

WATER TEMPERING PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:

When the shower or eyewash is activated, thepressure drop on a diaphragm opens the steam controlvalve (V-3). Water and steam flow are establishedinstantly heating the water and condensing the steam.A mixing valve (V-1) then blends the heated water withcold water to produce an output of 85°F water.Additional valves keep the system preheated, freezeprotected and scald protected. Steam valve remainsclosed should water supply be interrupted.

DESIGN FEATURES:• Uses existing plant steam and water supply• Provides 3 to 30 GPM of 85°F with an inlet water

pressure of 45 PSIG• Easy to install on any existing shower or eyewash/

shower combination• Compact, lightweight design easily supported by

pipe connections or factory mounting kit• Plant steam and water never mix...uses compact

hi-capacity heat exchanger• Maintains constant 85°F output regardless of inlet

water temperature (between 40°F and 85°F)• Preheated to provide instantaneous 85°F water• Freeze and solar overtemperature protection

included• No insulated tanks or expensive recirculation

systems required• Operates on typical plant steam pressure (45 PSIG

recommended)• Self-purging...no need for elaborate drainage

system• All components are in-line field serviceable• Durable fiberglass enclosure can be readily

removed for servicing• Union connections allow for quick and easy

installation• Conforms to OSHA and ANSI recommendations• Unaffected by sudden cold water pressure drops• Trap on steam inlet included

REDUNDANT CONTROL:Level 1: (V-1) This valve mixes heated and cold water

and compensates for the pressure dropthrough the heat exchanger and associatedpiping.

Level 2: (V-2) This valve opens when heater outflowtemperature reaches 105°F, bypassing waterback into the steam inlet to limit the heatexchanger output temperature.

Level 3: (V-3) Senses flow from V-2 and modulatesthe steam valve closed. Additionally, if watersupply is interrupted, the steam valve staysclosed until water flow is re-established.

Level 4: (V-4) Senses final water temperature andshuts off steam valve if water temperatureexceeds 85°F.

TOTMIXST.5/98

THERM-OMEGA-TECH, INC.

207 Witmer Road • Horsham, PA 19044-2212Phone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 52: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SPECIFICATIONS

ITEM DESCRIPTION

1 WATER MIXING VALVE (V1)

2 105°F BYPASS CONTROL (V2)

3 STEAM CONTROL (V3)

4 85°F CONTROL (V4)

5 CHECK VALVE

6 STN. STL. HEAT EXCHANGER

7 PREHEATING VALVE

8 ENCLOSURE

* FREEZE PROTECTION VALVE

* SCALD PROTECTION VALVE

HAT/FPFreeze ProtectionValve

HAT/RAOvertemperatureProtectionValve

THERM-O-MIX®

Tempered WaterSupply Station

COLD TEMPEREDHEIGHT WIDTH DEPTH WATER WATER CAPACITY

INLET OUTLET

26" 13 1/2" 13" 1¼" UNION 1¼" UNION 1¼" UNION 3-30 GPM(66.0cm) (34.3cm) (33.0cm) 45 PSIG** 45 PSIG** 85°F at 45 PSIG

***Where Therm-O-Mix® Station is to beused as Safety Shower or Eyewashsupply, final output temperature shouldbe specified by the Facilities MedicalAdvisor or other authorized personnel.

THERM-O-TECH, INC.PA. BUSINESS CAMPUS

207 WITMER ROADHORSHAM, PA USA 19044-2212

STEAMINLET

CONDENSATEOUTLET

Shipped motor freight, F.O.B. Horsham, PA;Shipping weight approximately 94 lbs.

THERM-OMEGA-TECH, INC. reserves theright to change the design and specifications.

1" UNION

PHONE: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

THERM-O-MIX® STATIONALL WEATHER INSTANT TEMPERED WATER SUPPLY

TO ORDER, SPECIFY: 85°F THERM-O-MIX® STATION

RequiredOutput Temperature ***

PARTS LIST

Visit us on the internet at: http://www.thermomegatech.comTOTMIXST.5/98

* Supplied separately - typical installation shown on drawing on left.For Freeze Protection see HAT/FP Bulletin.For Scald Protection see HAT/RA Bulletin.

** Recommended regulated supply pressures

Need tempered water from hot and cold water?Request our THERM-O-MIX®/WWM product fact sheet.

For mounting kit information, see our THERM-O-MIX® STATIONMOUNTING KIT product fact sheet.

Page 53: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERM-O-MIX STATION/WWMHIGH CAPACITY INSTANTTEMPERED WATER SUPPLY

WATER TEMPERING PROBLEMS?

CALL THE GURU

1-800-288-GURU

MIXSTWWM.11/97

* THE NEED *An instantaneous and reliable source of tempered water for a safety shower/eyewash system using a hot andcold water supply.

* THE PROBLEM *Conventional mixing valves are unsuitable as the means to provide tempered water at safety shower/eyewashstations. These valves by nature have the property of shutting off entirely if either the hot or cold water supply isinterrupted. This is dangerous and unacceptable for safety shower/eyewash systems where cold water must beavailable under all circumstances. To meet today’s OSHA and ANSI recommendations you must have a systemwhich can respond safely to both hot water and cold water supply failures.

* THE SOLUTION *The Therm-O-Mix Station/WWM . It’s WM-1 mixing valve acting in concert with it’s unique PWM-1 pressuresensing controller assure that cold water will flow to the shower and eyewash even if no hot water is available (aslong as the cold water supply is not shut off elsewhere in the system).This is accomplished using completelymechanical, self operating controls. No electricity or air required.

TRIPLE REDUNDANT SAFETY CONTROLS

PWM-1 Pressure Sensing Controller:Therm-Omega-Tech’s unique diaphragm operated valve actuatorsenses the water pressures on both the hot and cold water inletconnections. If hot water pressure is not present at the mixing valveinlet, this actuator will override the mixing valve and allow full flow ofcold water. If no cold water pressure is available at the mixing valveinlet, both the mixing valve and the diaphragm actuator will close offthe hot port to prevent dangerously hot water from flowing to the shower/eyewash system.

WM-1 Mixing Valve:The primary temperature control device is Therm-Omega-Tech’s three-way mixing valve. This valve is designed around our exclusiveThermoloid® sensor/actuator that automatically and accuratelyproportions the water flow in response to outlet water temperature. Thismixing valve simultaneously modulates both the hot and cold waterinlet ports to provide 85°F water to the shower/eyewash system. TheThermoloid® sensor/actuator is the most advanced and reliable thermalactuator of its type available today.

V-4 Safety Override:This control element senses the final water temperature and will positionthe PWM-1 pressure sensing controller to close off the hot water portof the mixing valve if the final water temperature is above 90°F.

( Also available as an all weather versionin NEMA4 enclosure - consult factory )

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 54: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MIXSTWWM.11/97

THERM-O-MIX STATION/WWMHIGH CAPACITY INSTANT TEMPERED WATER SUPPLY

OPERATION

After water flow is activated at the shower or eyewash, the outlet water temperature will reach 85°F when hotwater arrives at the mixing valve. The mixing valve then blends the hot and cold water to produce an outputof 85°F water. Therm-Omega-Tech, Inc. also manufactures a Therm-O-Mix Station for use where only plantsteam and cold water are available. Also available are auxiliary freeze protection and scald protection bleedervalves for use where freezing ambient temperatures or overheated lines (due to tracing or high solar heatgain) may be encountered.

DESIGN FEATURES

w Uses existing plant hot and cold water supplies

w Conforms to OSHA and ANSI recommendations

w All components are in-line serviceable

w Provides 3 to 30 GPM of 85°F water with inlet pressure of 30 psig

w Optional durable, all weather version in high visibility fiberglass enclosure available

w Compact, lightweight design easily supported by piping connections (under 15 lbs/6 kg)

w Easy to retrofit on existing shower or combination shower/eyewash systems

w Maintains constant 85°F (29°C) output regardless of inlet pressure and temperature variations

w All self-operating controllers - no power required

Phone: 215-674-9992 FAX: 215-674-8594

CALL THE VALVE GURU TOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

THERM-OMEGA-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

85°F (29°C) OUTLET1-1/4” NPT-M

Where the Therm-O-Mix Station/WWM is used as

a safety shower or eyewash supply, the final output

temperature should be specified by the facilities

medical advisor or other authorized personnel.

ITEM DESCRIPTION MATERIAL

1 Mixing Valve (WM-1) Bronze Casting

2 Press. Sens. Controller (PWM-1) Plated Aluminum

3 Safety Override (V-4) Machine Brass

Flexible Tubing

4.5”

7” NOM.

1” NPT-FCOLD INLET

5” NOM.

8” DIA.

HOT INLET1” NPT-F

3

1

2

All - Weather350 PSI Rated BUNA-N

Page 55: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERM-O-MIX® STATION MOUNTING KIT

BRACKET.5/98

• Proper testing and service of Therm-O-Mix®

Station requires access to inside of enclosure.Minimum offset from enclosure to wall shouldbe 7 inches.

• This mounting kit is specifically designed toprovide secure, rigid mounting without limitingaccess.

(Typical Therm-O-Mix® Station weight: 90 lbs)

Note: Moly or lag bolts to secure wall brackets towall are not included. Use 1/2” dia. bolts.

• All components are galvanized steel.

• Kit weight: 18 lbs.

• Wall mounting kit part number: TMMK

• Also available in all stainless steel.

Ask for part number: TMMK-SS

Wall Brackets (2)# 15836

Connectors (8 sets)# 12131

Brackets (L/R)# 354

Arms (2)# 15814

Pipe Clamp (2)# 114

THERM-O-MIX® STATION MOUNTING KIT

36”

16”

Visit us on the internet at: http://www.thermomegatech.com

Page 56: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL HAT/WWM-RFLUID TEMPERING VALVE

WATER TEMPERING PROBLEMS?CALL THE GURU1-800-288-GURU

OPERATION:The hot fluid connects to the side, pass throughconnection on the HAT/WWM-R valve. Thisconnection is never regulated so it always remainsopen regardless of temperature or valve position.

The hot fluid flow then passes over the thermalactuator which controls the cold fluid inlet port fortempering. If the hot liquid temperature is above thevalve setpoint, the cold fluid port is open. As the hotliquid cools, the valve automatically modulates toreduce the cold fluid inlet flow. If the hot fluid is belowthe specified temperature, the cold fluid inlet port isclosed, since no additional cooling is required.

HATWWMRA.2/99

APPLICATIONS:Can be used in applications where the fluid must betempered, for example, the discharge of condensateor boiler blowdown with cooler water before piping toa sewer or return system.

ADVANTAGES:Controls cooling of hot fluid to desired level beforereturn to system or discharge to sewer. Flow throughdesign facilitates discharge. Automatic temperaturecompensation conserves tempering fluid.

TYPICAL USES:• Condensate discharge from steam traps

• Condensate return headers

• Boiler blowdown drain lines

• Heat exchanger backup cooling

• Process discharge tempering

DESIGN FEATURES:• All stainless steel body

• Corrosion resistant - long service life

• Clog resistant design

• Narrow temperature band

• Easily installed with pipe wrench

• Installs in any orientation

• Modulation throughout range to conserve cooling

fluid yet will temper large quantities of hot fluid

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 57: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

CV OF COLD INLET

CV OF HOT INLET

MAX. OPER. PRESS.*

FULL OPEN TEMP.

SIZE W M L WEIGHT(NPT-F) in (mm) in (mm) in (mm) Lb (Kg)

1/2" 1.7 (43) 1.5 (38) 4.5 (114) .79 (.36)

3/4" 1.8 (46) 1.8 (46) 5.5 (140) 1.3 (.59)

WATER TEMPERING VALVEMODEL HAT/WWM-R

HEAT ACTUATED TRAP/FLUID TEMPERING

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

NPT-F SIZE (1/2" or 3/4")

HEAT ACTUATED TRAP

W-W MIXER-REVERSE

DESIRED SET POINT(°F)

1/2 HAT/WWM-R 125

** All stainless steel version available. Consult factory.

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONS

* Cold stream pressure should be at least 10 psi morethan hot stream pressure

** Other temperatures available upon request

353 Ivyland RoadWarminster, PA 18974

THERM-OMEGA-TECH INC.

TO ORDER, SPECIFY:

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 COLD INLET FITTING 303 STAINLESS STEEL

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 PLUG HOLDER 303 STAINLESS STEEL6 THERMAL ACTUATOR BRASS **

7 ACTUATOR CARRIER F.M. BRASS **

8 OUTLET FITTING 303 STAINLESS STEEL

9 HOT INLET FITTING 303 STAINLESS STEEL

COLDINLET

W

M

HOTINLET

OUTLET

6

2

1

3

5

8

4 9

7

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

QUARTER TURN SHUTOFF

COLDINLET

HOTINLET

HAT/WWM-R VALVE

H

C

HATWWMRA.2/99Visit us on the internet at http://www.thermomegatech.com

L

STRAINER

CHECKVALVE

1/2” 3/4”

1.5 2.0

2.2 4.0

200 PSIG

13.8 BAR ANY 10°F(5.6°C)

INCREMENT40°F(4.4°C) TO210°F(99°C)**

Page 58: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL HAT/WWMMODEL HAT/SWMWATER TEMPERING VALVES

WATER TEMPERING PROBLEMS?CALL THE GURU1-800-288-GURU

APPLICATIONS:The THERM-O-TECH HAT/WWM and HAT/SWM valvescan be used in any application in which a constant outflowof water at a specified temperature is desired. Thesevalves, like any mixing valve, must be installed with checkvalves on both hot and cold inlets for the HAT/WWM and atleast on the cold side for the HAT/SWM. Pressure reducingvalves are recommended on HAT/WWM installations inwhich system pressures are likely to vary. The PRV’sshould be adjusted to approximately 10-20% less thanaverage system pressure for accurate and constant outflowtemperatures. In some installations throttling valves may beused in place of PRV’s. These throttling valves should beset and locked for safety.

The HAT/SWM can be used to trace critical components that muststay warm, but below steam temperature at atmosphere (212°F or100°C).

TYPICAL USES:HAT/WWM

• Constant temperaturebaths

• Batching• Constant temperature

wash basins & sinks• Water circulation

systems

HAT/SWM• Direct injection water

heating• Hot water wash down

stations• Make-up water• Hot water tracing

STEAM

HAT ORTV/HAT

HAT ORTV/HAT

HAT/SWM

HOT WATER

COLD WATER

OPERATION:This self-contained valve is designed around a thermalactuator that automatically adjusts the steam or hot watercomponent to temper outflow water to the specifiedtemperature. The device is factory set and is not useradjustable, and is therefore tamper-proof. The valve isdesigned to yield outflow temperatures within a given range.If water is inadvertantly not turned on, the actuator turns offthe steam flow at the set point temperature, preventing thetypical "hose full of steam" problem. Typical set points (°F)available are 90, 105, 125, 145, 155, 180 & 210. (32, 41, 52,63, 68, 82 & 99°C)

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 59: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

STEAM CONTROL PORT

MAX. OPER. PRESS.*

STANDARDSETPOINT TEMPS.

(OTHERS AVAILABLE)

SIZE W M L WEIGHT(NPTF) in (mm) in (mm) in (mm) Lb (Kg)

1/2" 1.7 (43) 1.5 (38) 4.5 (114) .79 (.36)

3/4" 1.8 (46) 1.8 (46) 5.5 (140) 1.3 (.59)

WATER TEMPERING VALVEMODEL HAT/WWM & HAT/SWM

HEAT ACTUATED TRAP/WATER-WATER MIXING

HEAT ACTUATED TRAP/STEAM-WATER MIXING

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-MAIL: [email protected]

NPT SIZE (1/2 or 3/4)HEAT ACTUATED TRAPWATER-WATER MIXER (or SWM)DESIRED SET POINT(°F)

1/2 HAT/WWM 125

** All stainless steel version available. Consult factory.

PARTS AND MATERIALS

DIMENSIONS AND WEIGHTS SPECIFICATIONS

* Steam pressure should be at least 10 psi(0.7BAR) more than water pressure.

SEE 1/2" HAT/SWMCAPACITIES CHART FORFLOW CHARACTERISTICS

353 Ivyland RoadWarminster, PA 18974-2205

THERM-O-TECH INC.

TO ORDER, SPECIFY:

ITEM DESCRIPTION MATERIAL

1 TUBULAR BODY 304 STAINLESS STEEL

2 HOT INLET FITTING 303 STAINLESS STEEL

3 SEAT SEAL PTFE

4 OPERATING SPRING STAINLESS STEEL

5 RAM-TYPE PLUG STAINLESS STEEL6 THERMAL ACTUATOR BRASS **

7 ACTUATOR CARRIER F.M. BRASS **

8 OUTLET FITTING 303 STAINLESS STEEL

9 COLD INLET FITTING 303 STAINLESS STEEL

HOTINLET

W

M

COLDINLET

OUTLET

6

2

1

3

5

8

4 9

7

1/2 NPT - 3/8"3/4 NPT - 1/2"

200 PSI13.8 BAR

90°F(32°C) 105°F(41°C)

125°F(52°C) 145°F(63°C)

155°F(68°C) 180°F(82°C)

210°(99°C)

QUARTER TURN SHUTOFFON HOT WATER SIDE

HAT/WWM VALVE

MIN. 5 FT.

H

C

DO NOT INSTALL SHUTOFFON COLD WATER SIDE

PRV

PRV

Therm-O-Tech, Inc. reserves the right to changethe design and specifications without notice.

HATWWM.4/99

Visit us on the internet at: http://www.thermomegatech.com

Page 60: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

1/2” HAT/SWM CAPACITIES CHART

EXAMPLE:

1. Enter chart 1 at desired hot water flow rate (i.e. 8 GPM) and movehorizontally to the right to the curve. From this point, drop downvertically to read the required water pressure drop in PSI across thevalve(P1-P2) (29 PSI for the example; therfore, minimum supplypressure = 30+29 = 59 PSI).

2. Continue to move horizontally at the hot water flow rate into chart 2to the T line which represents the desired temperature rise of thewater (T2 - T1) (i.e. 125° - 65° = 60°F)

3. From the intersection point on chart 2, move down vertically tochart 3 to the intersection with the curve which represents the waterinlet pressure (P1) (i.e. 60 PSIG). From this point , move horizontally tothe left to the P3 scale and read the required minimum inlet steampressure (i.e. 100 PSIG).

It is desired to have a flow of 8 GPM of 125° F water at 30 PSIdelivery pressure, with a water supply temperature of 65°F.

PROCEDURE:

STEAMINLET

(P3)

COLDWATERINLET

(P1)(T1)

HOTWATER

OUTLET(P2)(T2)

swmchart 5.01

ISO 9001CERTIFIED

Page 61: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

3/4” HAT/SWM CAPACITIES CHART

STEAMINLET

(P3)

COLDWATERINLET

(P1)(T1)

HOTWATER

OUTLET(P2)(T2)

EXAMPLE:

1. Enter chart 1 at desired hot water flow rate (i.e. 15 GPM) and movehorizontally to the right to the curve. From this point, drop downvertically to read the required water pressure drop in PSI across thevalve (P1-P2) (2.5 PSI for the example; therfore, minimum supplypressure = 55+2.5 = 57.5 PSI).

2. Continue to move horizontally at the hot water flow rate into chart 2to the T line which represents the desired temperature rise of thewater (T2 - T1) (i.e. 160° - 60° = 100°F)

3. From the intersection point on chart 2, move down vertically tochart 3 to the intersection with the curve which represents the waterinlet pressure (P1) (i.e. 60 PSIG). From this point , move horizontally tothe left to the P3 scale and read the required minimum inlet steampressure (i.e. 110 PSIG).

It is desired to have a flow of 15 GPM of 160° F water at 55 PSIdelivery pressure, with a water supply temperature of 60°F.

PROCEDURE:

Page 62: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

SCALD PROBLEMS?CALL THE GURU 1-800-288-GURU

MODEL STVM VALVESILENT TYPE VORTEX MIXERFOR STEAM/WATER MIXING

OPERATION:Therm-Omega-Tech’s STVM valve uses uniquevortex technology for silent operation. Duringoperation, cold water enters the mixing valveand forms an inner vortex that moves from theinside out, while incoming steam forms anopposing outer vortex that moves from the outsidein. Mixing occurs as the two vortices collide,thoroughly mixing and heating the water to thedesired temperature.What’s especially remarkable about vortextechnology is what you don’t hear - the banging,popping, and crackling noises that come fromordinary mixing valves. That means there’s noneof the racket that can add stress to the workenvironment, and none of the cavitation that can

ADVANTAGES:Because of the unique vortex flow characteristicsinside the STVM valve, it is capable of mixingsteam and water without the usual noise andvibration associated with other types of mixers.As a safety feature, the thermal actuator in thevalve outlet is designed to turn off the steam flowinto the valve if the cold water flow into the valveis interrupted. The entire internal operatingmechanism(AKA cartridge) of the STVM valvecan be quickly and easily removed as a singleassembly by simply unscrewing the valve cap.This allows easy cleaning and service withoutremoving the valve from the line. The Unique flowcharacteristics of the vortices inside the valvecreate a scouring action that together with specialcoatings on the cartridge element minimize theeffects of mineral deposits on valve operation,assuring increased service life even under adverseconditions.

stvm_valve9.02

ISO 9001CERTIFIED

TYPICAL APPLICATIONS:Hot water supply for:• Process hot water• Batch fill operations• Spray cleaning systems for vessels• Commercial laundry hot water• Boiler water preheating, deaerating• Other direct steam injection heating

Page 63: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Visit us on the Internet at: http://www.thermomegatech.com

TO ORDER, SPECIFY:1” STVM 185

DESIRED SETPOINT(150ºF OR 185ºF)

STEAM SUPPLY SHUTS OFF15ºF ABOVE SETPOINT.

OPTIONAL THERMOMETER AND

THERMOMETER HOUSING AVAILABLE

ITEM DESCRIPTION MATERIAL

1” STVM Valve Body Bronze Casting

1” STVM Cartridge Brass

1” STVM O-Ring Pack EPDM / PTFE

SIZE W D L WEIGHT in (mm) in (mm) in (mm) in (mm) Lb (Kg)

1” NPTF inlets1-1/4” NPTM outlet 4.37 (111.0) 2.72 (69.1) 5.00 (127.0) 2.6 (2.08)

MODEL STVM VALVESILENT TYPE VORTEX MIXER

THERM-O-TECH INC.353 Ivyland Road

Warminster, PA 18974-2205

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)E-Mail: [email protected]

PARTS AND MATERIALS

Therm-Omega-Tech, Inc. reserves the right tochange the design and specifications withoutnotice.

stvm_valve9.02

MAX. OPER. PRESS. 150 PSI

FOR FLOW RATES, SEE CAPACITIES CHARTS

DIMENSIONS AND WEIGHTS

1.

2.

3.

NOTE:

MAX. OPER. TEMP. 400ºF

Standard Temp: 150ºF and 185ºFSpecial temperatures available on request

Sample Installation

Page 64: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

2. Selection Guide and CapacitiesThe graphs indicate the maximum flow of hot water atvarious temperatures for a given steam supply pressure.When selecting a temperature set point, ascertain the hotwater temperature and quantity required, and the waterand steam pressure available.

First select the desired temperature rise chart. From thebottom row, select the desired flow in GPM. From there,move vertically up the chart to the left hand column todetermine the amount of water and steam pressurerequired tp provide the desired temperature rise at thedesired flow rate.Example:

Example: User requires 50ºF temperature rise and 10GPM flow. Resultant pressures required are 83 PSIsteam and 65 PSI water. (Reference dashed lines).

185F STVM UNIT 50F RISEW/0 HOSE AND NOZZLE

0

20

40

60

80

100

120

3 4 5 6 7 8 9 10 11 12

FLOW(GPM)

PR

ES

SU

RE

(PS

IG)

STEAM

WATER

185F STVM UNIT 50F RISEW/0 HOSE AND NOZZLE

0

20

40

60

80

100

120

3 4 5 6 7 8 9 10 11 12

FLOW(GPM)

PR

ES

SU

RE

(PS

IG)

STEAM

WATER

185F STVM UNIT 100F RISEW/O HOSE AND NOZZLE

0

20

40

60

80

100

120

3.5 4 4.5 5 5.5 6 6.5 7 7.5

FLOW(GPM)

PR

ES

SU

RE

(PS

IG)

STEAM

WATER

150F STVM 50F RISEW/O HOSE AND NOZZLE

0

20

40

60

80

100

120

3 4 5 6 7 8 9 10 11 12

FLOW(GPM)

PR

ES

SU

RE

(PS

IG)

STEAM

WATER

150F STVM UNIT 80F RISEW/O HOSE AND NOZZLE

0

20

40

60

80

100

120

2 2.5 3 3.5 4 4.5 5 5.5 6

FLOW(GPM)

PR

ES

SU

RE

(PS

IG)

STEAM

WATER

Page 65: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TEMPERATURE CONTROL PROBLEMS?CALL THE GURU1-800-288-GURU

THERM-O-MIX VALVEDUAL PURPOSE MIXING OR DIVERTING VALVES

FOR CONSTANT TEMPERATURE

OPERATION:

THERM-O-MIX valves are designed around ourexclusive Thermoloid sensor/controller, the mostadvanced and reliable thermal actuator of its typeavailable today. THERM-O-MIX valves simultaneouslycontrol both hot and cold ports, to automatically andaccurately proportion the flow in response to fluidtemperature. On loss of cold or hot fluid supply theflow rate is reduced to a trickle. For fast response,these valves are compact and low mass.

For mixing applications, the THERM-O-MIX valve willproportion the flow from two inlet ports to produce thedesired outlet port temperature.

For diverting applications, the THERM-O-MIX valvewill divert the inlet flow to either of two outlet portsdepending on the fluid temperature.

TOTMIXVL.2/99

ADVANTAGES:The THERM-O-MIX VALVE has a precise temperatureoutput with varying input temperatures, even inrecirculation systems. It has a fast response with nosetpoint drift. THERM-O-MIX valves offer anti-scald,anti-chill protection, as required by many new plumbingcodes. THERM-O-MIX valves are factory tested andcalibrated, but they can be field adjusted within theoperating range of the Thermoloid® sensor/controller.The temperature can also be adjusted to yourparticular needs and locked.

FEATURES:• Constant output temperature.• Proportioning valve (simultaneous control of hot

& cold fluids).• Energy savings through lower supply temperatures.• Control of hot fluid, up to and including full shutoff.• Anti-scald protection• Tamper-resistant temperature lock at any point.• Nickel-plated bronze construction, Viton® o-rings*• Designed for easy maintenance.• Can be installed in any position.• Tested and certified under ANSI/ASSE 1017

TYPICAL APPLICATIONS:• Domestic Water • Oil• Photo Processing • Air• Heat Pump Systems • Hydraulic Fluid• Solar Hot Water • Space Heating• Public Facilities • Greenhouses• Greenhouses • Industrial WaterService

* Other materials available - consult factory.

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 66: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TO ORDER:STANDARDS: 1/2", 3/4", 1" THERM-O-MIX

SPECIFY SIZE (NPT-F)

STANDARD RANGES (OR SPECIFY IN ° F**) Tested and certified under ANSI/ASSE 1017

*90° - 120°F Range Models Meet National Plumbing Code Temperature Range**Optional Temperature Ranges from 40° - 200°F (4° - 93°C) - Consult Factory.

THERM-O-MIX VALVEPROPORTIONAL MIXING/DIVERTING VALVE

Max. Temp. 210°F (99°C) Max. Pressure150 PSIG

Size (NPT-F) Max. CV

1/2" 1.63/4" 2.1

1" 2.6

X

Y

Z

C - ColdInlet (-)

A - Mix Outlet

B - HotInlet (+)

SIZE DEM (in.) WT.(NPT-F) X Y Z LBS

1/2" 4.3 2.1 2.8 1.43/4" 4.3 2.1 2.8 1.21" 4.4 2.2 3.2 1.4

DIMENSIONS

TYPICAL APPLICATIONSCOOLING WATERCONTROL USINGRADIATOR OR HEATEXCHANGERValve shown in "di-verting" position tocontrol outlet tem-perature. In dottedposition, valve will"mix" to control inletwater to engine.

WATER SAVINGAPPLICATIONSValve as shownmaintains minimumflow through coolerto conserve water,requires internal leakport to permit smallflow for sensing.

PLUMBING DIAGRAMSFOR MIXING APPLICATIONS: FOR DIVERTING APPLICATIONS:

HOTINLET

COLDINLET

CONTROLLED TEMPERATUREOUTLET

HOTOUTLET

COLDOUTLET

VARYING TEMPERATUREINLET

LUBE OIL CONTROLValve shown in “diverting”position to control oilsump temperture. Indotted position, valve will“mix” to control oiltemperature to bearingsor manifold.

TEMPEREDWATER SUPPLYTherm-O-Mix valveinstalled as shown(on left sink) will pro-vide water at a speci-fied temperature forwashdown stations,etc.

INSTANTANEOUS DOMESTIC HOT WATER SUPPLIESWith Therm-O-Mix valves installed between hot and coldsupply lines, a recirculating pump can maintain a minimalflow across the valve from hot to cold, keeping the hot side"up to temperature"; and ready to provide a safe supplytemperature to the hot water faucet.

RECIRCULATING PUMP

CONSTANTTEMPERATURE

SINK

HOT COLD

COLDWATERSUPPLY

WATERHEATER

RAW WATERIN

RAW WATEROUT

COOLER

WATERPUMP

SURGETANK

ENGINE

VENTLINE

HEATLOAD

EXPANSION TANK

B PORT BLOCKED

HEATEXCHANGER

WATERPUMP

HEAT LOAD

HOT COLD

HEATEXCHANGER

Therm-Omega-Tech, Inc. reserves the right to change the design and specifications without notice.

Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

THERM-OMEGA-TECH INC.353 Ivyland Road

Warminster, PA 18974

Phone: 215-674-9992FAX: 215-674-8594

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)

70°-100°F (21°-38°C) 80°-160°F (27°-71°C) 85°-145°F (29°-63°C) 90°-120°F*(32°-49°C)110°-145°F (43°-63°C)130°-170°F (54°-77°C)

TOTMIXVL.2/99

AA

C B C B

OILPUMP

ENGINE A

C

A

C

B OILCOOLER

SUMP

Page 67: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODELM/D VALVE

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 68: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

OPERATION:The THERM-OMEGA-TECH Model M/D temperaturecontrol valve is designed for 3-way mixing or divertingapplications. For fast response, the valve is compact andlow mass. Therm-O-Tech's valves are designed aroundour exclusive Thermoloid sensor/controller thatautomatically and accurately proportions the flow inresponse to fluid temperature. The Thermoloid sensor/controller is the most advanced and reliable thermal actuatorof its type available today.

For mixing applications, the Model M/D will proportion theflow from two inlet ports to produce the desired outlet porttemperature.

For diverting applications, the Model M/D will divert orswitch the inlet flow to either of two outlet ports dependingon the fluid temperature.

The Model M/D valve is factory tested and calibrated.

TYPICAL APPLICATIONS:• Cooling water control-Radiator

• Cooling water control-Heat Exchanger

• Hydraulic fluid cooling systems

• Direct cooling with raw water

• Lube oil cooling control

• Constant temperature baths

• Constant temperature wash basins & sinks

• Loop-type circulation systems

• Direct injection water heating

• Hot water washdown stations

• Make-up water

• Electric system cooling

• Air conditioning

• Water conservation

MODEL M/D VALVEMIXING / DIVERTING VALVEFLOW CONTROL BASED ON FLUID TEMPERATUREWITHOUT ELECTRICITY OR EXTERNAL POWER

WATER TEMPERING PROBLEMS?CALL THE GURU1-800-288-GURU

SPECIFICATIONS:Materials: Body & cap: bronze alloyInternal cage: stainless steelThermoloid sensor/controller: brass & stainless steelOperating spring: stainless steelSeals: Buna N(Most special materials of construction are available)

Maximum operating pressure: 350 psig @ 250°F

Maximum operating temperature: 250°F(Higher temperatures are available)

Body rating: A.N.S.I. 250 Class

Nominal Operating Temperatures: 40°F(4.4°C) to200°F(93.3°C)(Special operating temperatures are available)

Connections: 1" NPT-F & 1 ¼” NPT-M

Flow Coefficient C V: 10.0

Weight: Approximately 5 lbs. net weight

MDVALVE.10/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 69: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MIXING / DIVERTING VALVESMODEL 1 Inch & 1 1/4 Inch M/D

DIMENSIONS

COLDOUTLET

VARYINGTEMPERATURE

INLET

FOR DIVERTING APPLICATIONS:

COLDINLET

HOTINLET

CONTROLLEDTEMPERATURE

OUTLET

FOR MIXING APPLICATIONS:

PLUMBINGDIAGRAMS

SIZE W X Y Z(NPTF) in (mm) in (mm) in (mm) in (mm)

1" 4.50 (114) 2.25 (57) 3.25 (82) 6.75 (171)

1 ¼” 4.50 (114) 2.25 (57) 2.50 (64) 6.00 (152)

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)or 215-674-9992

FAX: 215-674-8594E-MAIL: [email protected]

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-O-TECH THERM-O-TECH THERM-O-TECH THERM-O-TECH THERM-O-TECH INC.INC.INC.INC.INC.

TYPICAL CONTROL APPLICATIONS

WATER SAVINGAPPLICATIONSValve as shownmaintains minimumflow through cooler toconserve water,requires internal leakport to permit smallflow for sensing.

D I R E C TCOOLING WITHRAW WATER(1400F OR LESS)Valve shown in" d i v e r t i n g "installation. Mountvalve as shown indotted position for"mixing" applications.

AIRCONDITIONINGValve shown in"mixing" position tocontrol temperatureof inlet water torefrigeration systemcondenser. Valve indotted positioncontrols outlettemperature.

HEATEXCHANGER

HEAT LOAD

WATERPUMP

B PORT BLOCKED

EXPANSION TANK

MUST HAVE POSITIVEHEAD ON PUMP INLET

COOLINGTOWER

WATERPUMP

CONDENSER

HEATEXCHANGERVENT

LINE

HEAT LOAD

SURGETANK

COOLER

WATERPUMP

DISCHARGE

WATERINLET

FOOTVALVEWATER

PUMP

ENGINE

COOLING WATERCONTROL USINGRADIATOR ORHEAT EXCHANGERValve shown in"diverting" position tocontrol outlettemperature. In dottedposition, valve will "mix"to control inlet water toengine.

ELECTRICSYSTEMCOOLINGValve shown in"diverting" position tocontrol max.temperature fromtubes, batteries orother heat loads.Valve in dottedposition controls inlettemperature.

LUBE OILCONTROLValve shown in"diverting" position tocontrol oil sumptemperature. Indotted position, valvewill "mix" to control oiltemperature tobearings or manifold.

RAW WATERIN

HEATEXCHANGER

VENTLINE

RAW WATEROUT

COOLER

WATERPUMP

ENGINE

SURGETANK

OILCOOLER

ENGINE

SUMP

OILPUMP

C B

C B C BHOTOUTLET

Visit us on the internet at: http://www.thermomegatech.comMDVALVE.10/98

Page 70: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

OPERATION:The THERM-OMEGA-TECH Model M/D self-operatingtemperature control valve is designed for 3-way mixing ordiverting applications. Therm-O-Tech's valves aredesigned around our exclusive Thermoloid sensor/controllerthat automatically and accurately proportions the flow inresponse to fluid temperature. The Thermoloid sensor/controller is the most advanced and reliable thermal actuatorof its type available today.

For mixing applications, the Model M/D will proportion theflow from two inlet ports to produce the desired outlet porttemperature.

For diverting applications, the Model M/D will divert orswitch the inlet flow to either of two outlet ports dependingon the fluid temperature.

The Model M/D valve is 100% factory tested and calibrated.

TYPICAL APPLICATIONS:• Cooling water control-Radiator

• Cooling water control-Heat Exchanger

• Hydraulic fluid cooling systems

• Direct cooling with raw water

• Lube oil cooling control

• Constant temperature baths

• Loop-type circulation systems

• Make-up water

• Electric system cooling

• Air conditioning

• Water conservation

MODELS: 1 ½” M/D VALVE& 2” M/D VALVE

MIXING / DIVERTING VALVEFLOW CONTROL BASED ON FLUID TEMPERATUREWITHOUT ELECTRICITY OR EXTERNAL POWER

WATER TEMPERING PROBLEMS?CALL THE GURU1-800-288-GURU

SPECIFICATIONS:Materials: Body & cap: 316 SSInternal cage: 316 SSThermoloid sensor/controller: 303 SSOperating spring: 302 SSSeals: Buna N or as specified

Maximum operating condition: 250 psig @ 250°F,(17.2 bar @ 121°C)

Body rating: A.N.S.I. 150 Class

Nominal Operating Temperatures: 40°F(4.4°C) to200°F(93.3°C)(Other operating temperatures are available)

Connections: 1½" NPT-F & 2” NPT-F

Flow Coefficient (C V): 18.0

Weight: Approximately 11 lbs.(5.0 Kg)MD1-2.10/98

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 71: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MIXING / DIVERTING VALVESMODEL 1½" & 2” M/D

DIMENSIONS

COLDOUTLET

VARYINGTEMPERATURE

INLET

FOR DIVERTING APPLICATIONS:

COLDINLET

HOTINLET

CONTROLLEDTEMPERATURE

OUTLET

FOR MIXING APPLICATIONS:

PLUMBINGDIAGRAMS

SIZE W X Y Z(NPTF) in (mm) in (mm) in (mm) in (mm)

1½" 6.0 (152) 3.0 (76) 3.0 (76) 6.8 (173)

2” 6.0 (152) 3.0 (76) 3.0 (76) 6.8 (173)

CALL THE VALVE GURUTOLL FREE

1-800-288-GURU (4878)or 215-674-9992

FAX: 215-674-8594E-MAIL: [email protected]

353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

THERM-O-TECH THERM-O-TECH THERM-O-TECH THERM-O-TECH THERM-O-TECH INC.INC.INC.INC.INC.

TYPICAL CONTROL APPLICATIONS

WATER SAVINGAPPLICATIONSValve as shownmaintains minimumflow through cooler toconserve water,requires internal leakport to permit smallflow for sensing.

DIRECTCOOLING WITHRAW WATERValve shown in" d i v e r t i n g "installation. Mountvalve as shown indotted position for"mixing" applications.

AIRCONDITIONINGValve shown in"mixing" position tocontrol temperatureof inlet water torefrigeration systemcondenser. Valve indotted positioncontrols outlettemperature.

HEATEXCHANGER

HEAT LOAD

WATERPUMP

B PORT BLOCKED

EXPANSION TANK

MUST HAVE POSITIVEHEAD ON PUMP INLET

COOLINGTOWER

WATERPUMP

CONDENSER

HEATEXCHANGERVENT

LINE

HEAT LOAD

SURGETANK

COOLER

WATERPUMP

DISCHARGE

WATERINLET

FOOTVALVEWATER

PUMP

ENGINE

COOLING WATERCONTROL USINGRADIATOR ORHEATEXCHANGERValve shown in"diverting" position tocontrol outlettemperature. In dottedposition, valve will "mix"to control inlet water toengine.

ELECTRICSYSTEMCOOLINGValve shown in"diverting" position tocontrol max.temperature fromtubes, batteries orother heat loads.Valve in dottedposition controls inlettemperature.

LUBE OILCONTROLValve shown in"diverting" position tocontrol oil sumptemperature. Indotted position, valvewill "mix" to control oiltemperature tobearings or manifold.

RAW WATERIN

HEATEXCHANGER

VENTLINE

RAW WATEROUT

COOLER

WATERPUMP

ENGINE

SURGETANK

OILCOOLER

ENGINE

SUMP

OILPUMP

C B C BHOTOUTLET

Visit us on the internet at: http://www.thermomegatech.comMD1-2.10/98

Page 72: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Miscellaneous

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 73: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATIONS• Heat presses • Mixing & diverting• Steam kettles • Sample systems• Freeze protection • Calendering rolls• Overtemperature protection • Tempered water• Accurate steam tracing• Steam trap replacement• Precision pressure control• Sample temperature control• Batch or continuous control• Heat exchanger outflow control• Instrumentation temperature control• Temperature control in explosion hazard areas• Any process in which adjustability is necessary

DESIGN FEATURES• Low cost PID control (explosion proof option)• Easy set up and tuning• Fast response• No motors, gears, screws or mechanical feedback• High output force (mechanical)• Control any process• 4-20 ma signal from economical, standard temperature controller or computer I.O.• RS232 interface available on process controller• 24VAC operation on actuator• Ramp & soak capability on process controller

ELECTRICAL SPECIFIATIONS• Power 24 VAC 50/60Hz, 1.9 Amps Max• Repeatability 5% of full scale• Linearity 5% of full scale• Thermal Rejection 0.25%/degF ambient• Input Voltage Drop 100mV max @ 20mA• Adjustment Range +/- 15% of full scale• Response Time TBD sec on step change,

TBD sec on start up• Inputs 4-20mA, 0-2mA, 0-5V, 1-5V, 0-10V

2-10V. Can accept logic pulse outputcontrol with additional PCM (pulseConverter module).Can accept 0-5V, 1-5V, 0-10V, 2-10Vwith addition of external resistor.

EMPCULTRA SENSEELECTRONICALLY MODULATED POSITION CONTROL

FOR CUSTOM DESIGNSCALL THE GURU 1-800-288-GURU

empc2.02

ISO 9001CERTIFIED

OPERATIONThe EMPC uses advanced technology to sim-plify and reduce cost of complicated controlfunctions. The development of this deviceparalleled advances in digital electronics andmaterial science. There is simply no equal forpower, speed, reliability or cost.

The EMPC can be fitted to any standardTherm-Omega-Tech valve or may be adaptedto other control devices manufactured by anynumber of suppliers (consult factory for rec-ommendations). Process variables aresensed with standard transducers. This infor-mation is then processed and converted toprecise position information. The simplifiedelectronics of the EMPC goes quickly and di-rectly to the setpoint without overshoot or hunt-ing. Adjustment of controller power factor al-lows the EMPC to operate precisely withinvery narrow control bands, making it unlike anycontroller or positioner previously available.Auto tuning then becomes more accurate andprocess specific.

Page 74: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

MODEL ADVCONTAMINANT PROTECTIONFOR PNEUMATIC SYSTEMS

APPLICATION:Water and other contaminants can have

catastrophic and costly consequences on

pneumatic systems and equipment such as: air

compressors, air filters, separators, air dryers and

compressed air handling system drop legs.

Contaminants are the principal cause of failure,

wear and improper operation of pneumatic

equipment. Protect your investment with the

Therm-Omega-Tech Model ADV.

ADVANTAGES:Automatic Operation Low MaintenanceThe non-electric Model ADV purges water, oil, dust,rust, metals and other contaminants from pneumaticsystems automatically. The valve’s discharge rateadjusts on demand to accomodate varyingcondensation rates. The valve also features a largeoutlet that removes particles over 600 microns withoutclogging. Only five seconds of opening the outlet eachmonth guarantees years of optimal performance.

Eliminates Contaminants - Adds Life to Your SystemThe Therm-Omega-Tech Model ADV immediatelyremoves unwanted contaminants from the pneumaticsystem—before they harm your equipment. Reductionin contamination results in optimal performance ofpneumatic systems. The Model ADV adds years ofusable life to your system, while it reduces oreliminates downtime for maintenance and repair.

Three-Year Warranty - Guaranteed PerformanceThe Model ADV features extremely durable materialsand superior construction. Its patented technologyguarantees three full years of performance...manytimes longer than most drain valves.

DESIGN FEATURES:• Control mechanisms are separated from

contaminants• No electricity required• Install up to 150 feet away, or above system• Extends the life of pneumatic equipment• Removes water, oil, and contaminants

automatically• Three Year limited warranty• Easy to install

THERM-OMEGA-TECH, INC.

Bulletin adv.11/96

CONTAMINANTS PROBLEMS?CALL THE GURU 1-800-288-GURU

ISO 9001CERTIFIED

Page 75: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Manual Outlet 1/2” F-NPT

Automatic Outlet 3/8” NPT

Operating Pressure 20 - 150 psig (1.3 - 10 kg cm3)

Ambient Temperature 36° - 140°F (2° - 60°C)

Min. Equipment Requirement 1 HP (180 l/min.)

Max. Condensate Discharge rate 15 gal/hour (57 l/hr.)

Inlet Accessories

Bushing 1/2” x 1/4” NPT

Bushing 3/8” x 1/4” NPT

Hose Fitting 1/4” NPT

Hose 5/16” x 3/16” x 5’

Dimensions 6” x 4” x 8” (150 mm x 100 mm x 200 mm)

Weight 2.9 lbs. (1.3 kg)

Inlet 1/2” F-NPT

THERM-O-TECH INC.353 Ivyland Road

Warminster, PA 18974-2205

Visit us on the internet at: http://www.thermomegatech.com

Phone: 215-674-9992FAX: 215-674-8594

E-Mail: [email protected] THE VALVE GURU

TOLL FREE1-800-288-GURU (4878)

AUTOMATIC DRAIN VALVEMODEL ADV

CONTAMINANT PROTECTION FOR PNEUMATIC SYSTEMS

SPECIFICATIONS

8”

6” 4”

OPERATION

Page 76: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS
Page 77: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS
Page 78: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERMAL ACTUATORSSOLID-LIQUID PHASE CHANGE ACTUATORS

FOR CUSTOM DESIGNED ACTUATORSCALL THE GURU1-800-288-GURU

ACTUATOR.10/97

1-Actuator assembly includes return springs and rod ends; unit contractsin length up to several inches when cooled. 2,6-Conventional mediumoutput actuators. 3,12-Actuator assemblies including integral heater forremote control. 4,10-Actuator assemblies include integral valve cagewith valve seat, spring flange, seal grooves. 5,7,14-Long, thin actuatordesign; stroke nearly equal to actuator body length. 8,9-Typical miniatureactuators. 11-Conventional low output actuator. 13-Actuator withproprietary seal design for high reliability in extreme conditions. 15-Actuator with integral fluid sensing connections with over 2” stroke and200+lbs. output force.

OPERATIONThe thermal actuator is filled with Thermoloid® material,which changes phase from a solid to a liquid and expandsas the temperature increases. Since the material isessentially incompressible and encased in a rigid housing,only the piston can move and extend as the volume of thematerial increases. This motion can be used to operate awide variety of devices. When the Thermoloid® materialcools the volume contracts and allows the piston to retractif a return force is acting on the piston. The piston will notnormally retract unless a return force is present.

The phase change and resultant motion occurs over anarrow temperature range. This property allows precisecontrol of a device at a specific temperature with nosignificant effect outside the chosen control range.

APPLICATIONSThe precise motion of these thermal actuators can be usedto operate a wide variety of devices, limited only by theimagination of the designer. Temperature actuated valves,switches, latches, clamps and control devices are typicalapplications.

ADVANTAGESNo outside power source is required to produce motion.Temperature change alone can be used to operate a device;e.g., open or close a valve, move or release a latch, operatea switch. Because the Thermoloid® material operates inboth the solid and liquid phase, each of which are essentiallyincompressible, load changes on the piston (within designlimits) have little or no effect on operating temperature. Thisis in contrast to vapor-filled or liquid to vapor phase changedevices which are generally very sensitive to load changes(changing the load on these devices, e.g., changing springtension, is used to change the operating temperaturerange).

Since the operating temperature of solid-liquid phasechange actuators is determined by the Thermoloid®material properties (i.e., melting and solidificationtemperatures), the operating temperature is extremelystable, repeatable, and accurate. The properties of thesethermostatic materials are so precise that they are used asprimary reference standards by ASTM for instrumentcalibration.

DESIGN FEATURES• Long, powerful stroke• Rugged and compact• Reliable and reproducible• Wide choice of temperature ranges• Not effected by shock or vibration• Can be used in pressure or vacuum, liquid or gas• Custom mounting configurations available• Can be made from most machinable materials• Typical temperature change for maximum stroke: 10F°

to 20F°(5 to 11C°)• Start to stroke temperatures from about -30°F to 300°F

(-34°C to 149°C) or higher

The Therm-Omega-Tech, Inc. engineering staff will behappy to assist you in designing custom thermal actuatorsor complete thermal powered assemblies to meet anytemperature-sensitive control or actuating need.

15

THERM-OMEGA-TECH, INC.

353 Ivyland Road • Warminster, PA 18974-2205 USAPhone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 79: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

TERMS & CONDITIONS

Therm-O-Tech can also provide custom designed valves and assemblies for your applications.Contact the Factory for more information.

NOTE: Consult factory for pricing and delivery.

PRICES: All prices are subject to change without notice; however, prices quoted within sixty days of order will behonored at quoted price.

SHIPPING: All Shipments are F.O.B factory. Freight is prepaid, and added to the invoice.

TERMS: • Net thirty (30) days• +2% beyond thirty (30) days of invoice and for each additional thirty (30) days of invoice

GUARANTEE: Every actuator designed and manufactured by THERM-OMEGA-TECH, INC. is completely factory testedbefore leaving our facility. This gives you the assurance that the units will perform reliably for a long periodof time. We pass that confidence on to you in our prorated eighteen (18) month warranty.

The warranty cycle will be extended by three (3) months for actuators supplied through our authorizeddistributors and/or supplied with O.E.M. packaged equipment.

RETURNS: The factory should be consulted and a return authorization number obtained prior to any returnbeing made. No returns will be accepted without an RMA number. Actuators of standard design willbe subject to a 25% restocking charge if inspection determines equipment is in first class resalablecondition. Any rework required will be deducted from the credit in addition to the 25% restocking fee.Custom designed actuators are not returnable. All returned material should be shipped prepaid to thefactory.

ACTUATOR.10/97

Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

DIAPHRAGMTYPE ACTUATOR

1 PISTON

2 GUIDE

3 ANTI-CHAFING DISK

4 PLUG

5 DIAPHRAGM

6 ACTUATOR CUP

7 THERMOLOID® MATERIAL

SLIDING SEALACTUATOR

1 PISTON

2 ACTUATOR BODY

3 SEAL

4 THERMOLOID® MATERIAL

5 CLOSURE PLUG

6 CLOSURE SEAL

11

2 2

34

6

5

7

3 4

65

ACTUATOR IN “COLD” POSITIONBelow the phase change temperature, the Thermoloid® material is a solid atreduced volume. This allows the piston to be returned under spring force to opena direct-acting valve or device.

ACTUATOR IN “HOT” POSITIONAbove the phase change temperature, the Thermoloid® material is a liquid atincreased volume. This forces the piston to extend and close a direct-acting valveor device.

Page 80: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

EngineeringData

THERM-O-TECH, INC.ISO 9001

CERTIFIED

Page 81: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATION PROFILE #1INSTRUMENT ENCLOSURE VALVES (HEATING*)

Application: For the control of inside temperature of instrument enclosures or analyzer housings that are heatedvia steam or hot fluids.

Purpose & Background: Instruments/analyzers installed out-of-doors are exposed to adverse conditions and arecustomarily enclosed in insulated boxes to protect them from physical and weather damage. Many installations requirea certain inside temperature be maintained to prevent freezing, control viscosity or to maintain instrument calibration.Two systems are commonly utilized to provide such protection:

Electrical Trace ; using an electrical heat tracing cable. Normally provides excellent temperaturecontrol with integral thermostatic control but is costly to operate. Not suitable in many hazardouslocations and traced equipment is subject to freeze damage during power outages.

Steam/Hot Fluid Trace ; this is normally accomplished by dressing a copper or stainless steel tubearound the inside of an enclosure or by installing a coil or finned tube heating element inside anenclosure. Steam, heat transfer fluid, hot oil or water and even hot condensate from a steam main iscirculated through the loop or heater providing the source of heat to protect the instruments. Thisnormally provides excellent freeze protection but when uncontrolled can result in overheating ofthe instrumentation.

The Therm-O-Tech TV/SC-I valve was designed to provide safe and economicalcontrol of the heating medium to regulate the internal temperature of the enclosure.

The most common installation ofthe TV-SC-I valve is shown inFig. 1 : The actuator of the valveis inserted through the enclosurewall utilizing the integral bulk-head fitting provided with thevalve. In this arrangement feederconnections are external to theenclosure.

BULLETIN APPL.5/96

Fig. 1 Fig. 2 Fig. 3

Due to the increased use of tubebundles, where heat trace linesenter the enclosure with impulseor sample lines, a short bodydesign is required to allow allconnections to be within theenclosure. This can beaccomplished using the Therm-O-Tech TV/SC-A valve design asshown in Fig. 2.

The ITCH Assembly(Instrumentation ThermostaticallyControlled Heater) comescomplete with steam coil,mounting bracket, TV/HATvalves, and tubing bulkheadfittings, and may be mountedeither internally as in Fig. 2 , orwith external steam supplyconnections. (Fig. 3)

* Therm-Omega-Tech also has valves and vortex coolers for enclosure cooling applications as well as awide variety of pass-thru seals, grommets and gaskets for instrument enclosures. Call for information.

OPTIONALCONNECTIONFOR TRACING

IMPULSELINES

STEAMSUPPLY

TV/HATSTEAM TRAP

TV/HATSTEAM TRAP

TV/SC-ISTEAMHEATER

INSTRUMENT ENCLOSURE

STEAMSUPPLYTV/SC-A VALVE

STEAM COIL

TV/HATSTEAM TRAPAT OUTLET

TV/HATSTEAM TRAP

AT INLET

TV/HATSTEAM TRAP

AT INLET

INSTRUMENT ENCLOSURE

TV/SC-A VALVE

STEAM COIL

STEAMSUPPLY

TV/HATSTEAM TRAPAT OUTLET

Page 82: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

US/A = N.P.T. (F) ConnectionsTV/SC-A = Tube Connections

PROCESS LINE TRACING

APPLICATION PROFILE #2MANUAL CONTROL OF STEAM TRACING vs.

AUTOMATIC CONTROL USING US/A OR TV/SC-A VALVESEXAMPLE:A winterizing steam tracing system in a plant located in Philadelphia, PA consumes about 500 pounds per hour of steam.

This system was manually turned on when danger of freezing temperatures approached (mid-September) and turned off inlate Spring when danger of freezing had passed (mid-April). Total yearly operating hours are 5,088:

212 days x 24 hours = 5,088 hours in potential freeze season.

The plant's steam cost is $ 5.00 / 1,000 pounds of steam. The operating cost of this system can be calculated as follows:

COST OF MANUALLY OPERATED SYSTEM:

500 pounds per hour x 5,088 hours x $ 5.00/thousand pounds = $12,720.00 per winter season.

COST OF AUTOMATICALLY OPERATED SYSTEM:When using THERM-OMEGA-TECH ambient sensing TV/SC-A or US/A valves, steam tracing will be turned off automaticallywhenever ambient temperatures rise above 45°F (other closing temperatures can also be specified). Based on U.S.Weather Bureau data for Philadelphia, steam will be on for only 2,895 hours each winter.

500 pounds per hour x 2,895 hours x $ 5.00/thousand pounds = $ 7,237.50 per winter season.

SAVINGS REALIZED PER WINTER SEASON BY USING THERM-OMEGA-TECH VALVES:

$12,720.00 – $ 7,237.50 = $ 5,482.50 per year

SIMPLIFIED PAYBACK AS R.O.I. ( RETURN ON INVESTMENT)Assuming an installed cost of $ 500.00 for the THERM-OMEGA-TECH valve to control the above system, the simplifiedpayback for this application is:

$ 5,482.50 $ 500.00 = 11.0 R.O.I.

TRACING A CONTROL VALVE,PUMP CASE, ETC.

TV/HAT, HATor SST

TV/SC-A ORUS/A FORTRACERCONTROL

STEAM

TV/HAT,HAT or SST

TV/SC-Aor US/A

TV/HAT,HAT or SST

÷

APPL2.10/97Visit us on the internet at: http://www.thermomegatech.com or e-mail us at: [email protected]

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

PHONE 215-674-9992TOLL FREE 800-288-GURU (4878)FAX 215-674-8594

Page 83: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Great Falls, MT 9 4152 36 116.64 233.28 349.92 583.20 224.64 341.28 457.92 691.20

Buffalo, NY 8 3829 34 97.92 195.84 287.76 489.60 241.92 339.84 431.76 633.60

Charleston, WV 7 2716 46 115.92 231.84 347.76 579.60 295.92 411.84 527.76 759.60

Charlotte, NC 6 1769 59 127.44 254.88 382.32 637.20 343.44 470.88 598.32 853.20

Chicago, IL 8 3838 33 95.04 190.08 285.12 475.20 239.04 334.08 429.12 619.20

Cleveland, OH 8 3499 39 112.32 224.64 336.96 561.60 256.32 368.64 480.96 705.60

Houston, TX 5 229 94 169.20 338.40 507.60 846.00 421.20 590.40 759.60 1098.00

Los Angeles, CA 2 117 92 66.24 132.48 198.72 331.20 462.24 492.48 558.72 691.20

Memphis, TN 6 1829 58 125.28 250.56 375.84 626.40 341.28 466.56 591.84 824.40

Mobile, AL 4 759 74 106.56 213.12 319.68 532.80 394.56 501.12 607.68 820.80

New Orleans, LA 4 468 84 120.96 241.92 362.88 604.80 408.96 529.92 650.88 892.80

New York, NY 6 2856 34 73.44 146.88 220.32 367.20 289.44 362.88 436.32 583.20

Philadelphia, PA 7 2895 43 108.36 216.72 325.08 541.80 288.60 396.72 505.08 721.80

Pittsburgh, PA 7 3512 30 75.60 151.20 226.80 378.00 255.60 331.20 406.80 558.00

Portland, ME 8 4140 28 80.64 161.28 241.92 403.20 224.64 305.28 385.92 547.20

St. Louis, MO 7 2838 44 110.88 221.76 332.64 554.40 290.88 401.76 512.64 734.40

Seattle, WA 6 2915 33 71.28 142.56 213.84 356.40 287.80 358.56 429.94 572.40

Tulsa, OK 6 2127 51 110.16 220.32 330.48 550.80 326.16 436.32 546.48 766.80

10 20 30 50 10 20 30 50

Winterization Steam Use, lb/hr

NormalHours Below 45°F

(2)

Dollars Saved AnnuallyWith Tracer Steam On Only During

Months Freezing Can Occur (4)

(1) U.S. Weather Bureau Data. It is assumed that tracers for winterization are normally left on during this time.(2) THERM-O-TECH valves automatically turn on steam to tracers.(3) Based on number of hours ambient air temperature is above 45°F. THERM-O-TECH valves automatically turn

off steam to tracers.(4) Steam Cost Assumed: $5.00/1,000 lb. Steam Load should include needed heat plus loss due to leaks.(5) Steam Cost Assumed: $5.00/1,000 lb. It is assumed that steam use is a constant 10 lb/hr during "Summer".

Example: Winterization steam use may average 30 lb/hr during the 7 months when freezing can occur. For thebalance of the year (5 months), if tracer is allowed to remain active, steam use is assumed to be 10 lb/hr.

% Of SteamSavedDuringMonths

Freeze CanOccur

(3)

Number ofMonthsAnnuallyThat Air

TemperatureCan Fall To

32°F orLower (1)

Location

APPL2.10/97

Estimated Savings Per Tracer

Dollars Saved Annually,With Tracer Steam On 12 Months

(5)

Winterization Steam Use, lb/hr

Using Automatic Control Versus No Control

Page 84: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATION PROFILE # 3APPROXIMATE C V REQUIRED FOR FREEZE

PROTECTION OF UNINSULATED* WATER LINES

In a "Resupply System", a pressurized source replaces water. Freeze protection is provided by removing the colderwater from the system, and allowing warmer resupply water to modulate the valve closed. Larger valves will not wastewater, and it is impossible to oversize. The rate at which water must be removed can be calculated as follows:

1) GPM =

Where: GPM = Gallons per minute of water flowA 1 = Pipe flow area, ft2

A 2 = Exposed pipe surface area, ft2

tw = Temperature of resupply water, oFta = Minimum air temperature, oFd = ID of pipe, ft

The valve flow coefficient (CV) required to remove water at this rate iscalculated as follows:

2) CV =

Where: GPM = Gallons per minute of water flowCV = Total required CV of valves∆P = Pressure drop across valves (PSIG)

(If valves discharge to atmosphere, ∆P = PS where PS is supply pressure.)

Example: Freeze protect a 125 foot long run of uninsulated 2" pipe whenthe minimum air temperature is -15oF. The resupply water is40oF minimum, at 60 PSIG.

From the pipe data chart, for 2" schedule 40 pipe:

A1 = 3.36 sq. in./144 = 0.023 ft2

A2 = 0.622 ft 2/ft x 125 ft = 77.8 ft2 also: tw = 40oF

d = 2.067 in./12 = 0.172 ft ta = -15oF

1) GPM = = 9.6 GPM 2) CV = = 1.24*

Choose the valve or valves required to give a CV of 1.24 or more. The use of several smaller valves will provide

redundancy. Valves must be installed as close to the far end of the pipe as possible. Any side branches must be

individually protected.

*For properly insulated lines, use 25% of the CV indicated as an approximation of required CV

40.1 d2 (tw - 32)

A1 A2 (0.5tw - ta + 16)

∆P

GPM

WATERMAIN

FREEZE PROTECTION OFWATER MAINS & PIPE RUNS

HAT/FPFREEZEPROTECTIONVALVE

(0.023) (77.8) [(0.5) (40) - (-15) + 16]

40.1 (0.172)2 (40-32)

9.6 GPM

60 PSIG

HAT/RA FOROVERTEMPERATUREPROTECTION

HAT/FP FREEZEPROTECTION

MEETS OSHAGUIDELINES

APP3.4/99

PHONE 215-674-9992TOLL FREE 800-288-GURU (4878)FAX 215-674-8594

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Page 85: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APP3.4/99

1.0 2 3 5 10 20 30 50 100 200 300

50.0

30.0

20.0

10.0

5.0

3.0

2.0

1.0

0.5

0.3

0.2

0.1

.05

.03

.02

.01

25,00020,00015,000

10,000

5000

25002000

1500

1000

500

250200

150

100

50

2520

15

10

5

GA

LLO

NS

P

ER

M

INU

TE

(G

PM

)VALVE FLOW CAPACITIES

PO

UN

DS

PE

R H

OU

R (

PP

H)

P (PSI)∆Visit our internet site at: http://www.thermomegatech.com or e-mail us at: [email protected]

Page 86: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICAAPPLICAAPPLICAAPPLICAAPPLICATION PRTION PRTION PRTION PRTION PROFILE #4OFILE #4OFILE #4OFILE #4OFILE #4INFORMATIONAL SUMMARY

Water Supplies for Safety Showers & Eyewash Stations

There are many concerns in industries equipped with safety shower/eyewash units related to watersupply quality, OSHA and ANSI safety requirements, and providing safe and comfortable watertemperatures for employees if a shower/eyewash must be used.

1. Water Quality: As a general rule of thumb, if it is safe enough to drink, it is safe enough toshower with. An area of concern is insuring that the water supply is free of any sedimentbuildup and any bacteria that might have developed in the standing water supply. ANSIstandards recommend that all emergency shower/eyewash devices be checked on a weeklybasis to ensure proper working conditions, confirm adequate water supply and to flush anysediment/bacteria out of the system. Many shower manufacturers offer units with pipelinestrainers or recommend they be installed on a dedicated water supply line.

2. Water Capacity: Plumbed emergency shower/eyewash equipment requires a line size thatwill provide adequate flow. The chart below shows typical water pressure and supplyrequirements.

Device PSIG GPM (Min.) Inlet Size

Plumbed Eyewash Device 30 3 1/2"Plumbed Face Washes 30 7-8 1/2"Plumbed Drench Showers 30 30 1-1/4"

ANSI's "American National Standard for Emergency Eyewash and ShowerEquipment " (Z358.1-1990) gives the following performance requirements:

ShowerShower Height Not less than 82" nor more than 96" from standing levelWater Spray Pattern 20" minimum diameter - 60" from standing levelCenter of Water Spray 16" from any obstructionPotable Water Delivery Minimum of 20 GPM/meeting water spray patternControl Valve & Actuator Stay ON type - OFF to ON in one second - easily locatedLocation to Hazard Maximum 10 seconds travel and within 100 feet of hazardIdentification Well lighted, sign, area highly visible

APP4.5/98

PHONE 215-674-9992TOLL FREE 800-288-GURU (4878)FAX 215-674-8594

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

Page 87: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Eye/Face WashPotable Water Delivery Minimum of 0.4 GPM - dual stream flushingVelocity Soft spent streamLocation to Hazard Maximum 10 seconds travel and within 100 feet of hazardNozzles Covers to protect from airborne contaminantsNozzle Height Not less than 33" nor more than 45" from standing levelControl Valve & Actuator Stay ON type - OFF to ON in one second - easily locatedIdentification Well lighted, sign, area highly visible

Drench HosePotable Water Delivery Minimum of 3 GPM - low velocityLocation to Hazard Maximum 10 seconds travel and within 100 feet of hazardControl Valve Stay ON type - OFF to ON in one second - easily located

Other ConsiderationsDelivered Water Temperature 60° to 95°F (16° to 35°C)Freeze Protection Required Mechanical or ElectricalHostile Environment Protection Enclosure - Heated/Non-HeatedAlarms Required Local and/or RemoteModesty Consideration Does not discourage equipment useMaterial Safety Data Sheets Available on file in safety or medical departmentMedical Assistance Available in plant or outsideEmergency Vehicle Available in plant or outsideInspection Monthly record should be maintainedMaintenance Each unit activated weekly to flush line and verify flowTraining All employees instructed on proper use of equipment

Most of these are clearly understandable. Further clarification is offered for two of the items under"Other Considerations".

3. Delivered Water Temperature: 60° to 95°F (16° to 35°C). In most cases the high temperaturecondition is of critical concern and a high inspection area for OSHA ; however, low temperaturehazards are also a growing concern.

a) Overtemperature/Scald Protection: Supply lines or shower units installed outside aresubject to solar heating with internal water temperatures reaching 150°F (66°C) and above.Likewise, indoor units and lines may be subject to high ambient temperature conditions fromprocess, steam or condensate lines. This overtemperature water must be purged from thesystem to prevent scalding.

Relationship of Time and Temperature: Studies1 have demonstrated that there are two criticalfactors which determine the risk of a burn injury occurring: the temperature of the material andthe length of time the skin is exposed to the temperature. For water, the following chart providestime/temperature relationships required to cause a full-thickness (3rd degree) burn.

WATER TEMPERING / OVERTEMPERATURE PROBLEMS? CALL THE VALVE GURU...

Phone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Page 88: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Temperature °F (°C) Time Temperature °F (°C) Time

120 (49) 9.5 min. 140 (60) 5 sec.125 (52) 2.0 min. 145 (63) 2.5 sec.130 (54) 30 sec. 150 (66) 1.8 sec.135 (57) 15 sec. 158 (70) 1.0 sec.

Remember! Normal safety standards dictate a minimum of 15 minutes washdown in the shower!

The most common device used for overtemperature/scaldprotection by shower manufacturers and retrofitted byusers is a self-contained temperature activated valve, suchas the Therm-Omega-Tech HAT/RA or IC/RA designs.

The internal sensor/actuator operates over a 10°F (5.5°C)temperature differential, with the valve being fully closedat 95°F (35°C), starting to open and allowing a small waterflow when fluid temperature is sensed at 96°F (35.5°C),and increasing to full flow if temperature reaches 105°F(40°C) or above. This purges the hot water from thesystem, to be replaced by the cooler water in the supplyline.

Valves are normally installed at a low point in the station(see typical piping layout) to insure:

1. Full station and system piping are purged of hot water2. Valve discharge will not reduce available flow to shower or eyewash unit.

b) Low Temperature Shock/Hypothermia Protection: Many facilities are now considering theeffects of low water temperature in relationship to the length of time a person will shower, or thecombined effects of hypothermia and shock to the victim due to extended exposure to cold water(Remember: 15 minutes or more is required).

A 1993 case relates that a power plant employee was splashed with a hazardous solution. Followingplant safety procedures, he at once went to the nearest shower unit, started a full body shower, andalmost immediately jumped out of the shower due to the cold water. Knowing the potential dangerfrom burns, four fellow employees forced him back into the shower, holding him in place for therequired 15 minute washdown; by then, he was unconscious and in shock.

Many manufacturers are addressing this concern by offering a number of variations of temperedwater supply systems. These range in size and design from electric or steam water heaters to hot/cold water mixing assemblies.

HAT/RA

1 The above time and temperature relationship chart was developed by a number of studies conducted by:Lewis & Love (1926); Wu, Yung-Chi, N.B.S. (1972); Dr. M.A. Stoll, for U.S. Navy (1979)

THERM-OMEGA-TECH, INC. • 207 Witmer Road • Horsham, PA 19044-2212

Visit us on the internet at: http://www.thermomegatech.com

THERM-O-MIX® TEMPEREDWATER SUPPLY

MEET OSHAMEET OSHAMEET OSHAMEET OSHAMEET OSHAGUIDELINESGUIDELINESGUIDELINESGUIDELINESGUIDELINES

HAT/RA FOROVERTEMPERATUREPROTECTION

HAT/FP FREEZEPROTECTION

Page 89: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

In line with the needs within the industry, Therm-Omega-Tech's Constant Temperature WaterSupplies are available as either a unit that mixes hot and cold water supply like the Therm-O-Mix ®/WWM or a unit that utilizes plant steam to indirectly heat the supply water like the Therm-O-Mix ®

Station . Both have redundant controls for safety, and are self-contained; no electrical connectionsare required. The most common temperature requested is about 85°F (29°C); not warm enough toopen the skin pores and not too cold to deter usage. Information on both the mixing valves and mixerassemblies are available from the factory or your local Therm-Omega-Tech distributor. Therm-Omega-Tech can also custom engineer recirculation loop systems for servicing multiple safetyshower/eyewash stations.

4. Freeze Protection: The second item under "Other Considerations" refers to freezeprotection, mechanical and/or electrical. Many shower manufacturers offer heavilyinsulated and electrically heat traced shower designs. In some areas, electricaltracing cannot be used safely (due to explosion hazards), and potential poweroutages could well result in freeze damage.

A few manufacturers provide backup freeze protection on traced units by theaddition of mechanical freeze protection valves while others (and many users)depend only on freeze protection valves equal to the Therm-Omega-Tech HAT/FPand IC/FP designs.

The HAT/FP, like the HAT/RA scald valve, is a temperature actuated device; inthis case, operating over a 35° - 40°F (1.7° - 4.4°C) range to enhance waterconservation.

The valve starts to open when sensing a fluid temperature of 35°F (1.7°C) or less,closing when the resupply water temperature reaches 40°F (4.4°C).

THERM-O-MIXTHERM-O-MIXTHERM-O-MIXTHERM-O-MIXTHERM-O-MIX ®®®®® STATION/WWM STATION/WWM STATION/WWM STATION/WWM STATION/WWMWater/water mixingWater/water mixingWater/water mixingWater/water mixingWater/water mixing

Constant temperature suppliesConstant temperature suppliesConstant temperature suppliesConstant temperature suppliesConstant temperature supplies

THERM-O-MIXTHERM-O-MIXTHERM-O-MIXTHERM-O-MIXTHERM-O-MIX ®®®®® STATION STATION STATION STATION STATIONUtilizes steam/to indirectly heat supplyUtilizes steam/to indirectly heat supplyUtilizes steam/to indirectly heat supplyUtilizes steam/to indirectly heat supplyUtilizes steam/to indirectly heat supply

waConstant temperature supplywaConstant temperature supplywaConstant temperature supplywaConstant temperature supplywaConstant temperature supply

THERM-OMEGA-TECH, INC. • 207 Witmer Road • Horsham, PA 19044-2212Phone: 800-288-4878 • Fax: 215-674-8594 • E-Mail: [email protected]

Visit us on the internet at: http://www.thermomegatech.com

STAINLESSSTEEL HEATEXCHANGER

TEMPEREDWATEROUTLET

COLDWATEROUTLET

STEAMINLET

CONDENSATEDRAIN

HAT/FP

Page 90: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATION PROFILE #5THERM-OMEGA-TECH HAT vs CONVENTIONAL STEAM TRAPS

OPERATING COST SAVINGS

The THERM-OMEGA-TECH HAT valves provide substantial savings when compared to the cost of operating conventionalsteam traps. The HAT valves sense condensate temperature and open to allow flow only when the condensate temperatureis below the setpoint, well below saturated steam temperature. The condensate forms a liquid seal ahead of each valve preventinglive steam losses. Also, the sensible heat in the condensate between steam temperature and the HAT discharge temperatureis used for heating.

Most properly functioning conventional steam traps have inherent live steam loses: at least 2 lbs/hr. for inverted bucket traps, andover 5 lbs/hr for disc traps. Actual field studies have shown that live steam losses of disc traps increase considerably with time inservice, with loses of 20 lb/hr after less than one year of service being not unusual. Losses from other types of conventional trapsalso increase with time, but usually less than loses from disc traps.

For this example, we will use 2 lb/hr of live steam loss for conventional traps in good condition and compare this to HAT valves which have zero live steam loss. Further, HAT valves achieve additional savings by discharging condensate atreduced temperature. These additional savings can be calculated based on the value of the heat content at varying dischargetemperatures.

COMPARE OPERATING COSTS FOR TYPICAL SYSTEM:One hundred 3/8" steam tracers (50 to 75 feet long)

70 psig steam pressure (316°F saturated steam temperature)Assumed steam cost @ $5.00/1000 lbs or $5.00/1,000,000 BTU

Estimated individual trap load: 20 lb/hrTotal system load: 100 X 20 lb/hr = 2000 lb/hr

HAT CONVENTIONAL TRAPSDischarge Temperature 165°F 316°FHeat of Condensate (From Steam Tables) 133 BTU/lb 286 BTU/lbLive Steam Loss Per Trap 0 lb/hr 2 lb/hr

SENSIBLE HEAT SAVINGS:286 BTU/lb - 133 BTU/lb = 153 BTU/lb Saved by HAT

2000 lb/hr X 153 BTU/lb X 8760 hr/yr X $5/1,000,000 BTU:Annual Savings Based On Reduced Condensate Temperature: $13,403

ANNUAL COST OF LIVE STEAM LOSS FOR CONVENTIONAL TRAPS:2 lb/hr per trap X 100 traps X $5/1000 lbs X 8760 hr = $8760

SUMMARY OF ANNUAL SAVINGS FOR EXAMPLE SYSTEMHAT CONVENTIONAL TRAPS

SAVINGS OF LIVE STEAM LOSS $ 8,760 $0SAVINGS FROM SENSIBLE HEAT $ 13,403 $0TOTAL SAVINGS: $ 22,163 $0SAVINGS PER TRAP $ 222 $0

CONCLUSION: A typical steam tracer system using THERM-OMEGA-TECH's HAT valves can save at least$222 per valve each year.

Based on an average cost of $97 each for the THERM-OMEGA-TECH valve and neglecting installation labor, thesavings will provide a simplified return on investment (R.O.I.) of 230%:

R.O.I. = $222/$97 = 2.3 or 230% or Payback = 5 months

THERM-O-TECH INC.353 IVYLAND ROAD

WARMINSTER, PA 18974-2205

PHONE 215-674-9992TOLL FREE 800-288-GURU (4878)FAX 215-674-8594

Page 91: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

STEAM TRACING BASICS*

Heat tracing is used for liquid-containing pipelines to prevent the liquids from freezing or becoming too viscous.With pipelines containing gases, heat tracing prevents gas components from condensing.

Heat tracing will normally be required when:

• The lowest ambient site temperature will be below the freezing point of the liquid carried in thepipes. An exception must be made for underground water-pipes installed below the ground frostlevel. Examples of liquid lines requiring heat tracing are: phosphoric acid, molten sulfur, glacialacetic acid, benzoic acid, cresol, naphthalene, phthalic anhydride, sorbitol, p-xlene, and water.

• The liquid becomes highly viscous at ambient temperatures. Examples are: certain crude oils,fuel oils, polymeric materials, waxes, bitumen and tar residues, and caustic soda liquor.

• The gas carried in the line has a dewpoint above the ambient temperature and, condensation ofliquid from the gas is undesirable. Examples are: fuel gas in oil refineries where the liquid causestrouble in the gas burners; natural gas containing moisture that may cause freezeup of controlvalves or even the whole system; compressor suction lines (liquid is harmful to compressors); andH2S/water vapor (causes corrosion on condensation.)

In winterizing practice, water lines are insulated in an effort to avoid tracing. However, there is always a heatloss from insulated lines. If the liquid cooling resulting from this heat loss cannot be tolerated, heat tracing willbe necessary.

If there is no heat tracing, the line may have to be disassembled, with associated high costs and long shutdowntimes.

The length of a traced line is quite variable. It may be a few feet in a process area, a few thousand feetbetween offices and the process area, or over a hundred miles as in the case of underground lines carryingcrude oil or fuel oil.

Still, steam tracing is commonly used because there is a surplus of low-pressure steam available in mostplants.

Since steam has a high latent heat, only a small quantity is required for a given heating load. Also, steam hasa high film heat-transfer-coefficient, condenses at constant temperature, and flows to the point of use withoutpumps.

The simplest method of external tracing is to wrap copper tubing around valves, pipe fittings and instruments.This procedure is unsuitable for horizontal runs because steam condensate collects at low points and mayfreeze during a shutdown. (THERM-OMEGA-TECH, INC., as well as most engineers, recommend thathorizontal runs be traced by strapping a single run of copper tubing to the bare underside of the pipeline.There are different means of insulating and increasing the thermal efficiency of the trace.)

It is essential to ensure that the trace lines are self-draining.

The length of a single trace tube (from steam supply valve to steam trap is limited by the pressure drop in thetrace. The trap should have a condensate drainage capacity to match the heating load. At a steam pressureof 100 psig or higher, the length of a single trace should not exceed 200 ft. If the steam pressure is lower, atracer length of 100 ft. is recommended.

* excerpts from an article by I.P. Kohli, M.Sc.Excerpted by special permission from Chemical Engineering, March 26, 1979, copyright 1979, by McGraw-Hill,Inc., New York, NY10020

STEAM TRACING PROBLEMS? CALL THE VALVE GURU TOLL FREE: 1-800-288-GURU (4878)

Page 92: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

0 212 180 970 1150 27.01 216 183 968 1151 24.02 219 187 965 1152 25.03 222 190 964 1154 22.54 224 193 962 1155 21.05 227 195 961 1156 20.06 230 198 959 1157 19.57 232 201 957 1158 18.58 235 203 956 1159 18.09 237 206 954 1160 17.010 240 208 952 1160 16.515 250 218 945 1163 14.020 259 227 940 1167 12.025 267 236 934 1170 10.530 274 243 929 1172 9.535 281 250 924 1174 8.540 287 256 920 1176 8.045 292 262 915 1177 7.050 298 267 912 1179 6.755 303 272 908 1180 6.260 307 277 905 1182 5.865 312 282 901 1183 5.570 316 286 898 1184 5.275 320 290 895 1185 4.980 324 294 892 1186 4.785 328 298 889 1187 4.490 331 302 886 1188 4.295 335 306 883 1189 4.0100 338 309 881 1190 3.9110 344 316 876 1192 3.6120 350 322 871 1193 3.3125 353 325 868 1193 3.2130 356 328 866 1194 3.1140 361 334 861 1195 2.9150 366 339 857 1196 2.7160 371 344 853 1197 2.6170 375 348 849 1197 2.5180 380 353 845 1198 2.3190 384 358 841 1199 2.2200 388 362 837 1199 2.1250 406 381 820 1201 1.75300 422 399 805 1204 1.5350 436 414 790 1204 1.3400 448 428 776 1204 1.1450 460 441 764 1205 1.0500 470 453 751 1204 0.90600 489 475 728 1203 0.75750 513 503 697 1200 0.451100 558 560 629 1189 0.391450 593 607 565 1172 0.291800 622 650 501 1151 0.222200 650 697 424 1121 0.162600 675 746 334 1080 0.123000 696 805 211 1016 0.08

PROPERTIES OF SATURATED STEAM

SPECIFIC HEATSteam

Temperature°F

GagePressure

PSIG

SensibleHeatbtu/lb

LatentHeatbtu/lb

TotalHeat ofSteambtu/lb

SpecificVolumecu ft/lb

Page 93: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

Air Binding : The process of steam trap closing due tothe presence of air rather than steam. This slows downthe discharge of condensate and the ability of a steamsystem to reach its desired temperature.

Blow-Down Valve: A valve used when blowing pipelinedirt or scale from a strainer screen or boiler drum.

British Thermal Unit (Btu): The quantity of heatrequired to raise one pound of water one degreeFahrenheit.

Capacity: The maximum amount of condensate thatcan be discharged by a steam trap at specific conditionsof temperature and pressure differential (between its inletand outlet). Capacity is measured in pounds per hour.

Condensate: Water that is the result of steam changingfrom vapor to a liquid.

Cycle: The opening and closing action of a steam trapthat allows it to pass condensate and then stop thepassage of steam.

Dirt Pocket: A length of pipe in the discharge line ofsteam heated equipment that allows the collection (bygravity) of pipeline scale and dirt.

Discharge Temperature: The temperature ofcondensate (measured at a steam trap’s inlet) while it isbeing discharged. Sometimes referred to as thetemperature at which a steam trap starts to open.

Enthalpy : The total energy content of a fluid, includingboth heat and mechanical energy.

Flash Steam: Steam that results when saturated wateror condensate is discharged to a lower pressure. It issteam that could not exist at a higher pressure.

Flash Tank: A vessel or tank where flash steam isaccumulated for subsequent use.

Latent Heat of Vaporization: Heat that produces achange of state without a change in temperature suchas, changing water into steam, sometimes referred tosimply as “latent heat”.

Modulate: The partial opening and closing of a steamtrap thereby regulating the discharge flow of condensate.Modulation is in contrast to a full open/full closed modeof operation.

PSIA: Pounds per square inch absolute - a measure ofpressure including atmospheric pressure.

PSIG: Pounds per square inch gauge - a measure ofpressure excluding atmospheric pressure.

Safety Load Factor: A factor by which the calculatedcondensate load is multiplied to determine the capacitya trap should possess to properly serve its selectedapplication. The safety load factor is used toaccommodate system variables and uncertaintiesaffecting the condensate flow rate.

Sizing: The process of matching the condensatedrainage requirements of an application to a steam traphaving a suitable capacity.

Saturated Condensate: Condensate that has atemperature equal to that of the steam with which it is incontact.

Saturation Steam: Steam that has a temperature equalto that of the condensate with which it is in contact.

Saturation Curve: Graphic representation of the boilingpoint of water at various pressures (the pressure andtemperature at which saturated steam and condensateexist).

Saturation Temperature: The temperature at whichsaturated steam and condensate exist.

Sensible Heat: Heat that produces a temperature risein a body (such as water).

Steam, Dry: Steam having no water droplets suspendedin it.

Steam, Live: “Live steam” is an expression commonlyused to describe steam that is still able to do useful work,in contrast to flash steam at atmospheric pressure.

Steam, Total Heat Of: The sum of BTU's per pound ofboth the sensible heat (of condensate) and the latentheat (of vaporization).

Steam, Wet: Steam having fine water dropletssuspended in it, and as a result, having a lower heatcontent than dry steam.

Steam Binding: The process of steam keeping a steamtrap closed and thereby preventing the discharge ofcondensate that has formed upstream of the trap. Thiscondition results when the condensate discharge lineto a steam trap is subjected to sufficient heating that thecondensate in it is changed back into steam therebyblocking the flow of condensate to the trap.

Steam Separator: A device that removes entrainedwater droplets from steam flow.

Steam Tables: Tables that list the properties of steamand condensate at various pressures and temperatures.

Steam Tracing: The use of steam to:1. Heat or maintain the temperature of a process

liquid in a pipeline.2. Prevent water lines and related equipment from

winter freeze-ups.3. Provide uniform temperature in and around

instruments so as to help maintain their calibration.

GLOSSARY OF TERMS

STEAM TRACING PROBLEMS? CALL THE VALVE GURU TOLL FREE: 1-800-288-GURU (4878)

APP5. 11/02

Page 94: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATION PROFILE # 6HOT WATER TRACING SYSTEM

APPLICATION:

Some chemical products must beheated to an optimum

temperature aboveambient temperature, but arealso sensitive to overheating, e.g.:

formaldehyde.

THERM-OMEGA-TECH's HAT/SWM valves can be used to provide a convenient, economical,reliable and effective hot water tracing system. Steam and water supplies are all that must beconnected to the valve.

At an eastern specialty chemicals plant, it was required to maintain formaldehyde lines at about100°F. Lower temperatures would affect product quality, while higher temperatures would cause theformation of formic acid and other undesirable side products.

The solution was to install THERM-OMEGA-TECH's HAT/SWM-100 and HAT-100 valves whichtogether provide both temperature control and backup safety high limit control. Approximately 100psig steam and 50 psig water were piped to each HAT/SWM valve. The outlet from the valve thensupplied the 3/8" tracer lines on various formaldehyde process piping. At the end of each tracer linejust before connection to the return system, a HAT-100 valve was installed. After the system wasstarted-up, the water temperature at the outlet of the HAT/SWM was approximately 100°F, exactly asthe system design specified. As the safety backup, if for any reason the tracer temperature at thetracer end exceeds 110°F, the HAT-100 will close off to prevent overheating. In this particular case,the customer chose to recycle the heated water to the cooling tower sump, where the water wascooled for reuse. A pump drawing from the cooling tower sump supplies water to the HAT/SWMvalves.

In addition to the HAT/SWM and HAT valves, additional system protection and reliability was achievedby installation of THERM-OMEGA-TECH's HAT/FP valves at key locations and low points. TheseHAT/FP valves provide positive freeze protection to system components and piping in the event of afailure of the steam supply, which could happen if the boiler or its controls fail. The HAT/FP valveswill drain the water from the system at 35°F to prevent freeze damage.

For further information about an application of this system, or for help in solving your other temperaturecontrol problems, please call THERM-OMEGA-TECH, INC. at 1-800-288-4878 to talk to an applicationengineer.BULLETIN APP6.11/95

HAT ORTV HAT

HAT ORTV HAT

EXCESS TORETURN OR

DRAIN

RESERVOIR

HOT WATER

STEAM

COLD WATER

PUMP

HAT/SWM

Page 95: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

APPLICATION PROFILE # 7UTILIZING HOT CONDENSATE/FLASH STEAM

FOR AUXILIARY HEATING

The superintendent of a mid-size steam plant supplying a centralized steam distribution system took a unique approachto solving two problems on the system.

The first problem was a back pressure build up in the condensate return system due to mechanical-design steam trapsdischarging at close to steam temperature. This resulted in high temperatures in the return, with a two phase flow of hotcondensate combined with flash steam, pressurizing the return and surging within the condensate flash tanks. Theresulting high temperature/back pressure greatly reduced the capacity of steam traps throughout the distribution system.In several cases it reduced the heat output of some equipment, and increased water-hammer problems in steam feederlines.

A second problem within the distribution system was the lack of adequate space heaters or unit heaters in a number ofwork and storage areas, even though steam and return lines were run through the area.

The unique approach to solving both problems was to utilize the hot condensate from drip stations to supply steam/hotwater unit heaters for auxiliary heating, controlling the hot water/condensate discharge from the heater with the THERM-OMEGA-TECH's HAT valve (Heat Actuated Trap). The design of the HAT valves allows the user to select the actualoperating temperatures of the HAT valve maximizing recovery of usable heat (ie: open for discharge at 150°F; valvecloses on a 10°F(5.6°C) rise - no flow at 160°F(71°C).

Fig. 1 - Typical steam main driptrap installations.

Fig. 2 - Typical installation of unit heater, supplied fromdrip station, with HAT valve controlling dischargefrom unit heater. Refer to THERM-OMEGA-TECH's HAT data sheet for sizes and temperaturerange of the HAT valve.

STEAM MAIN

TRAP

STRAINER

STEAM MAIN

STEAM MAIN

TRAP

TO RETURNSTRAINER

TRAP

HAT VALVEUNIT HEATER

STRAINER

↓↓↓↓↓

↓↓↓↓↓

APP7.5/00

ISO 9001 CERTIFIED

Page 96: ISO 9001 THERM-O-TECH, INC. CERTIFIED TABLE … contained valves/TOT-Catalog.pdf · Therm-O-Mix Station WWM Therm-O-Mix Station Mounting Kit HAT/WWM-R ... STANDARD SPECIFICATIONS

THERM-OMEGA-TECH, INC.THERMAL VALVE AND ACTUATOR

APPLICATION QUESTIONNAIRE

There are many variables in the design of a valve or actuator. Specific features can be designed into the device tooptimize it for an application. The application parameters below will be used to consider a standard or custom design forthe device. Please provide the following information for our evaluation and recommendations:

FOR ACTUATORS:• Stroke required; minimum and maximum allowable?

• Load on actuator; how will the load change over the stroke range?

• Temperature range to produce stroke?

FOR VALVES:• Valve operating mode required: open or close on temperature rise?

• What fluid will pass through the valve?

• What flow capacity is required and at what pressure drop?

• How tightly must valve shut off?

• Is control leakage required and how much?

FOR VALVES AND ACTUATORS:• Power available, if remote actuated?

• Response time required?

• Materials of construction or fluid exposures?

• Maximum and minimum exposure temperatures?

• Maximum and minimum exposure pressures?

• Cycle life requirements?

• Allowable envelope dimensions?

• Preferred mounting configuration?

• Vibration, shock exposures?

• Other special requirements dictated by your application?

• Prototype quantities?

• Production quantities?

• Need Date for prototypes and/or production quantities?

Contact Information:Name:

Phone:

Fax:

Email:

© 2001 by Therm-Omega-Tech, Inc.353 Ivyland Road

Warminster, PA 18974-2205Phone: 800-288-4878 or 215-674-9992

Fax: 215-674-8594Email: [email protected]

All rights reserved