iso 3382-3 for sustainable open-plan officessustainable open-plan office bourne hill offices,...
TRANSCRIPT
![Page 1: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/1.jpg)
ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICES
ANC Annual Conference – 29th June 2016
Anthony Chilton
![Page 2: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/2.jpg)
OVERVIEW
Sustainable open-plan office
Case Study
3382-3 Measurements
Post occupancy evaluation
Design approach
![Page 3: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/3.jpg)
SUSTAINABLE OPEN-PLAN OFFICE
Bourne Hill Offices, Salisbury
Conventional Sustainable
Mechanically ventilated Naturally ventilated
Mechanically cooled Passively cooled (concrete soffits)
Low ceilings, high screens High ceilings, low screens
![Page 4: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/4.jpg)
CASE STUDY - KEYNSHAM
![Page 5: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/5.jpg)
CASE STUDY - KEYNSHAM
![Page 6: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/6.jpg)
CASE STUDY - KEYNSHAM
![Page 7: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/7.jpg)
KEYNSHAM – EXTERNAL NOISE
![Page 8: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/8.jpg)
KEYNSHAM – EXTERNAL NOISE
Hard to provide masking noise without disturbance.
50
55
60
65
70
75
80
0 6 12 18 24 30 36 42 48 54 60 66 72 78 84
LAe
q,1
0s
[dB
]
15 minutes of traffic noise (10 second LAeq values)
LAFmax = LAF90 + 17dB
![Page 9: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/9.jpg)
KEYNSHAM – NATURAL VENTILATION
Vent Area approx. 5% of floor area (or 10% of façade area)
![Page 10: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/10.jpg)
KEYNSHAM – ACOUSTIC LOUVRES
![Page 11: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/11.jpg)
0
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
Sou
nd
Lev
el [
dB
]
Octave Band Frequency [Hz]
Measured unoccupied LAF90
NR30
NR35
NR40
MEASURED INDOOR NOISE LEVEL
LA90 = 40dB
All vents fully open
![Page 12: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/12.jpg)
KEYNSHAM - ABSORPTION
50% of the ceiling area is exposed concrete to provide passive cooling.
The other 50% is perforated aw=0.7 (Class C)
Absorbent outer surfaces to balustrades. Slatted timber.
Absorbent desk dividers.
![Page 13: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/13.jpg)
REVERBERATION CONTROL
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
63 125 250 500 1000 2000 4000 8000
T20
[s]
Octave Band Frequency [Hz]
Reverberation Time, T20(average of 18 interrupted source measurements)
250Hz – 2kHz average = 0.75s
![Page 14: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/14.jpg)
KEYNSHAM - SCREENING
Minimal screening – only desk dividers.
1100mm high (from floor).
Do not block direct sound.
![Page 15: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/15.jpg)
KEYNSHAM – SUMMARY
Low masking noise.
Low absorption.
Low screening.
What is the significance for privacy?
![Page 16: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/16.jpg)
3382-3 MEASUREMENTS
rD (Distraction Distance)
LwA=68.4dB
![Page 17: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/17.jpg)
SPEECH INTELLIGIBILITY
STI
Distance [m]
![Page 18: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/18.jpg)
SPEECH INTELLIGIBILITY
![Page 19: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/19.jpg)
DISTRACTION DISTANCE
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0 2 4 6 8 10 12
STIP
A
Distance From Source [m]
rD=5.9m
![Page 20: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/20.jpg)
CLASSIFICATION
Is Class B suitable for Keynsham?
Finnish Institute of Occupational Health
(Keränen, Hongisto, Virjonen)
Class rD
A <5m
B 5 - 8m
C 8 - 11m
D 11 - 15m
E > 15m
![Page 21: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/21.jpg)
POST-OCCUPANCY EVALUATON
Total Performance of Low Carbon Buildings
8 office buildings in the UK, 16 in China.
4 POE acoustic questions.
Acoustic control parameters will be recorded.
![Page 22: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/22.jpg)
CONTROL PARAMETERS
Occupancy
Activity Type (similar to NF 31-199)
Noise Levels
Ventilation Conditions
![Page 23: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/23.jpg)
POE QUESTIONS
If you are dissatisfied with noise levels from colleagues in
your office, please indicate on the plan provided the area in
which the activity of colleagues can cause you disturbance
(see example below).
My Position
Area causingdisturbance
![Page 24: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/24.jpg)
DESIGN APPROACH
http://www.ttl.fi/en/work_environment/physical_factors/acoustictool/Sivut/default.aspx
![Page 25: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/25.jpg)
Screen Height 0% 20% 40% 60% 80% 100%
900mm
LAF90 = 34dB 1300mm
1700mm
Screen Height 0% 20% 40% 60% 80% 100%
900mm
LAF90 = 37dB 1300mm
1700mm
Screen Height 0% 20% 40% 60% 80% 100%
900mm
LAF90 = 40dB 1300mm
1700mm
Screen Height 0% 20% 40% 60% 80% 100%
900mm
LAF90 = 43dB 1300mm
1700mm
Average aw of Ceiling
Average aw of Ceiling
Average aw of Ceiling
Average aw of Ceiling
CLASSIFICATION MAPS
Acoustic Classification(Finnish Institute of Occupational Health)Keynsham
Preferred
![Page 26: ISO 3382-3 FOR SUSTAINABLE OPEN-PLAN OFFICESSUSTAINABLE OPEN-PLAN OFFICE Bourne Hill Offices, Salisbury Conventional Sustainable Mechanically ventilated Naturally ventilated Mechanically](https://reader030.vdocuments.us/reader030/viewer/2022040901/5e720ae2e89ed1280f085439/html5/thumbnails/26.jpg)
CONCLUSIONS
Noise ingress - LAFmax 55dB
Electronic sound masking? – LAF90=43dB
Average aW of ceiling 0.5
Screen height 1350mm
Screens can be glazed above 1100mm.