Sensor: 2.75”H x 3.88”W x 1.5”D Compatible control panels: Qolsys IQ Panel 2 Frequency: 319.5MHz Battery: 3V GP CR123A (x2) Operating Temperature: 14°F to 122°F Detection Range: 20ft Max and 5ft Min Intended for use with IQ Panel 2 Supervisory signal interval: 70 min (approximately) Intended for use with 3/16” and 1/4” plate or tempered glass. SPECIFICATIONS IQ GLASS S-LINE INSTALLATION MANUAL Ceiling Walls Mounting Height: The sensor should be mounted between 6.5ft and 8.5ft above the floor. All protected glass must be within a clear line of sight of the sensor and within the 20ft max range. Ceiling mount Wall mount CHOOSE INSTALLATION LOCATION STEP 1 IQ GLASS-S Note: for UL/cUL listed the device shall be secured using the provided mounting screws. STEP 2 STEP 3 DETACH FACE PLATE STEP 4 STEP 5 REPLACE FACE PLATE SECURE TO SURFACE REMOVE BATTERY TAB Place your panel in “autolearn" mode Open and close the case to “tamper” the device Customize name and settings as desired and touch “ADD” ADD STEP 6 LEARN INTO PANEL Note: Detector LED will flash rapidly for 5 minutes as part of initial power up sequence. Note: For UL/CUL installations use this device only in conjunction with compatible Qolsys wireless alarm system IQ Panel 2.

Upload: others

Post on 03-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IQ Glass-S Installation Manual - Qolsys

Sensor: 2.75”H x 3.88”W x 1.5”D Compatible control panels: Qolsys IQ Panel 2 Frequency: 319.5MHz Battery: 3V GP CR123A (x2) Operating Temperature: 14°F to 122°F Detection Range: 20ft Max and 5ft Min Intended for use with IQ Panel 2 Supervisory signal interval: 70 min (approximately)Intended for use with 3/16” and 1/4” plate or tempered glass.

SPECIFICATIONS

IQ GLASS S-LINE INSTALLATION MANUAL

Ceiling

Walls

Mounting Height: The sensor should be mounted between 6.5ft and 8.5ft above the floor. All protected glass must be within a clear line of sight of the sensor and within the 20ft max range.

Ceiling mount

Wall mount

CHOOSE INSTALLATION LOCATION

STEP

1

IQ GLASS-S

Note: for UL/cUL listed the device shall be secured using the provided mounting screws.

STEP

2STEP

3DETACH FACE PLATE

STEP

4STEP

5REPLACE FACE PLATE

SECURE TO SURFACE

REMOVE BATTERY TAB

Place your panel in “autolearn" mode

Open and close the case to “tamper” the device

Customize name and settings as desired and touch “ADD”

ADD

STEP

6LEARN INTO PANEL

Note: Detector LED will flash rapidly for 5 minutes as part of initial power up sequence.

Note: For UL/CUL installations use this device only in conjunction with compatible Qolsys wireless alarm system IQ Panel 2.

Page 2: IQ Glass-S Installation Manual - Qolsys

Document#: IQGS-IM-02-18 Revision#: 2/14/18 Issue Date: FEB 2018 Qolsys Product #: QS1431-840 [email protected]

CONTACT TECH SUPPORTGOT QUESTIONS?Qolsys Inc. proprietary.

Reproduction without permission is not permitted.FCC ID: 2ABBZ-RF-ARGB

IC: 11817A-RFARGB

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.

TESTING MODE

STEP

7a

FG-701 Glassbreak Simulator

Test Mode: Place the sensor in test mode by disconnecting the batteries for 30 seconds then reconnecting. Test mode is active for 5 minutes upon the sensor powering on. The LED blinks every second when the sensor is in test mode. The IQ Glass-S does not transmit an RF Signal while it is in Test Mode. Please refer to the table on the right for the LED indicator guide. The sensor will exit test mode after the first 5 minutes of power up.

CONDITION RED LED

Initial Power Up

Test Mode

Test Mode, alarm event

Normal Mode, alarm event

Low Battery

Flash rapidly for 5 minutes

Flash once per second

Rapid flash for 2 seconds

SOLID for 5 seconds

Flash once every 30 seconds

LED Indicator Guide:

Sensitivity: Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The factory default is set to MAX. Please refer to the table below to customize the sensitivity.

ON

12

SENSITIVITY DETECTION RANGE

MAX

MEDIUM

LOW

LOWEST

20ft

1 2

13ft

8ft

5ft

OFF

ONOFF

OFF

OFF

ON

ON

ON

Switches: Set dip switches based on desired detection range.

ACTIVATE TEST FLEX MAN

Red StartButton

Set the FG-701 switches to the TEST and MANual modes.

Position the FG-701 near the protected glass and point the speaker directly at the glass break detector.

IMPORTANT: If window coverings are present, close them fully and hold the FG-701 behind the window coverings for testing.

Press the red start button and the FG-701 will generate a burst of glass break audio.

If the LED on the IQ Glass-S sensor flashes rapidly for 2 seconds an alarm event has been detected and the range is acceptable for audio. If the LED does not flash, position the IQ Glass-S closer to the glass and try again.

Note: The IQ Glass-S does not transmit an RF Signal while it is in Test Mode.

1.

2.

3.

To properly test the IQ Glass-S sensor, the FG-701 Glassbreak Simulator is required.

STEP

7b

STEP

7c

TESTING MODE

TESTING MODE

SECURE

CONNECTSUSING

319.5 MHz

EquipmentBP21056