ionizer guide (bar type). feature of new ionizer (bar type) ■ feature of new ionizer (bar type)...
DESCRIPTION
■ Product variety I Basic model (IZS40)Basic model (IZS40) Specialized model for ionizing function. Ionizing only by turning on the power. (AC adaptor is prepared as option) Static electricity detection model (IZS41)Static electricity detection model (IZS41) Built in ion balance sensor is added to the fundamental ionizing ability. Type of the control equipment (such as PLC) connection. Extendable wiring. Various alarm functions are equipped. Able to remote control. Conventional feedback sensor and the auto balance sensor can be connected. Reduced swing-voltage keeping static electricity removal speed of pulse type ionizer. Improved ion irregular attainment on conventional pulse type ionizer at the short distance installation. Appropriate for ionizing target (such as semiconductor devices) of weak to electric stress. High performance model Dual AC model (IZS42)Dual AC model (IZS42)TRANSCRIPT
IONIZER guide (bar type)
■Feature of new ionizer (bar type)Feature of new ionizer (bar type)• Variety of product able to suit customer's specification• Max. length 3.4m for the tenth generation FPD manufacturing• Maintainability improved electrode needle structure• Optimized piping structure saves air• Cover for electrode cartridge fall prevention is prepared as
option• CE and UL scheduled
■■Product variety IProduct variety I• Basic model (IZS40)Basic model (IZS40)
Specialized model for ionizing function. Ionizing only by turning on the power.(AC adaptor is prepared as option)
• Static electricity detection model (IZS41)Static electricity detection model (IZS41)Built in ion balance sensor is added to the fundamental ionizing ability.Type of the control equipment (such as PLC) connection. Extendable wiring. Various alarm functions are equipped. Able to remote control. Conventional feedback sensor and the auto balance sensor can be connected.
Reduced swing-voltage keeping static electricity removal speed of pulse type ionizer.Improved ion irregular attainment on conventional pulse type ionizer at the short distance installation. Appropriate for ionizing target (such as semiconductor devices) of weak to electric stress. High performance model
• Dual AC model (IZS42)Dual AC model (IZS42)
■ Product varietyProduct variety IIIIImage of ion production of each type
IZS40&IZS41 (AC Type) [Conventional]
IZS42 (Dual AC Type) [New developed]
Positive and negative Positive and negative pole ions are generated pole ions are generated one by one. one by one. Group Group of ion reach target.of ion reach target.
Large swing voltageLarge swing voltage
Positive and negative Positive and negative pole ions are generated pole ions are generated at the same time. at the same time. Uniformly ion reaches Uniformly ion reaches the target.the target.
Small swing voltageSmall swing voltage
High voltage generatorHigh voltage generator
DualizedDualized
Swing voltageSwing voltage Swing voltageSwing voltage
+---++
+
+
++++ + ----- - ----- -++++ +------ - -++++ + +++ +++++ + +++ +
-- -
++++ + +++++++++ +
++++++ +----- - ---- -
--- - - ---- --- - ---- --
DC 24V
Control Circuit
Hi voltage generato
+---- --
+
+
+++++ +
++++ + +++ +
++----- -
--- -++++ +----- -
------- -
DC 24V
Control Circuit
Hi voltage generator
+---- --
+
+
+++++ +
++++ + +++ +
++----- -
--- -++++ +----- -
------- -
0V 0V
■ Max. length 3400 mm• 10th generation glass panel (2,880x3,080)
electricity neutralization by one unit.
• Cartridge type electrode needle adoptedPossible to clean it by detaching at maintenance.The special cleaning tool is prepared. Reduction at maintenance man-hour.
■ Maintainability improved electrode needle structure
special cleaning tool
Bar length 340 to 3,400mm preparedBar length 340 to 3,400mm prepared
■Conservation of Air by optimized pipe designOptimized design between Pipe size with blow nozzle size
make uniform blow performance by whole area of bar
nonuniformitynonuniformity
Non optimizedNon optimized OptimizedOptimized
Uniformity on the whole area of barUniformity on the whole area of bar
■The fall prevention cover is prepared (Optional)• For the prevention of unforeseen electrode cartridge fall
■ CE/UL standard is scheduledCE marking:2004/108/EECUL: U.S.Standard for Electrostatic Air Cleaners,UL867,fourth editionCSA:Canadian Standard for Electrostatic Air Cleaners,CAN/CSA C22.2 No.187-M1986
Pictutre is for IZS31Pictutre is for IZS31
■SpecificationSpecification
IZS40 IZS41 NPN( ) IZS41 PNP( ) IZS42 NPN( ) IZS42 PNP( )
AC DC、
FluidOperating pressureGuarantee resistingpressureConnecting tubing O.D.
Discharge Parmissiion
Maintenance
Maintenance output
IrregularityHigh Voltage Irregularity
discharge
Compliance with overseas standards/ directive
CE(2004/108/ EEC)UL(U.S. Standard for Electrostatic Air Cleaners,UL867,fourth edition)
CSA(Canadian Standard for Electrostatic Air Cleaners,CAN/CSA C22.2 No.187-M1986)
Vibration resistance Durability Hz Amplitude XYZ each 2 hours50 1mmShock resistance /100m s2
Operating ambient humidity With no condensation35~80%Rh( )Material Enclosure ABS resin Electrode cartrige PBT resin: :
Effective discharge distance at Sencing DC mode50~2000mm (200~2000mm )Operating ambient temperature,Operating fluid temperature ℃0~50
Max. load current: 100 mAResidual voltage: 1 V or less (At load
current 100 mA)Max. applied voltage: 28 VDC
Max. load current: 100 mAResidual voltage: 1 V or less (At load
current)
Function Ionbalance control by internal sensor Needle dirt ditection High Voltage Irregularity discharge ditection Discharge is suspended Emission of static、 、 ( )、electricity is suspended Link System Wireless remote control Optional Connecting External Sensor、 、 ( )、
OutputSignal
Max. load current: 100 mAResidual voltage: 1 V or less (At load
current 100 mA)Max. applied voltage: 28 VDC
Max. load current: 100 mAResidual voltage: 1 V or less (At load
current)
Power supply voltage +/ - %AC100 240V AC Adaptor OptrionalDC24V 10( ~ : )
InputSignal ―
Connect toGNDVoltage range DC5V or less:
Comsunption Current 5mA or less
Connect to 24VDCVoltage range DC19V Power Sulpply~
VoltageComsunption Current 5mA or less:
Connect toGNDVoltage range DC5V or less:
Comsunption Current 5mA or less
Connect to 24VDCVoltage range DC19V Power~
Sulpply VoltageComsunption Current 5mA or less:
Air purgeAir (Clean and dry)
or Less0.5MPa0.7MPa
φ φ φ6、 8、 10
Output for emitting electricity +/ - V7000Ion balance*1 +/ -30V
Ionizer ModelIon generate method Corona DischargeMethod of applying voltage AC Sencing AC DC、 、 Dual AC