i/o update 2018 · 2018-05-02 · 5069-serial : generic ascii/modbus rtu & ascii generic ascii...
TRANSCRIPT
PUBLIC
Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 1
I/O Update 2018
• Flex 5000
• Compact 5000
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 2
FLEX 5000™ I/OShipping in 2018!
Performance
1 Gb EtherNet/IP™
1 Gb Backplane Speed
Easy snap-on installation
Removal and Insertion Under Power
(RIUP)
Network Media and Topology
2 Copper/2 Fiber Ports
Supports DLR, Star, Linear, PRP
Standard I/O
32 Channel Digital In/Out
8 Channel Analog In/Out
Consistent I/O Wiring
Direct Termination of 2, 3 & 4
wire devices
Safety I/O (SIL 3, PLe, Cat. 4)
16 Channel Digital In/Out
4 Channel Analog In/OutRugged Design
Operating
Temperature:
-40 °C…70 °C
Extreme
Environments:
Class G1, G2, and G3
Hazardous
Environments:
Class I, Div. 2
Zone 2 Groups
A, B, C, D, E, F
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 3
FLEX 5000™ I/OFlexibility in Design and Maintenance
Simplified System Design and Maintenance
Mount up to 8 or 16
I/O Modules
Dual Color Light-emitting
Diodes (LEDs) for Status &
Diagnostics
Interconnect Cable
Bank Expansion
Adapter Power
Removal Terminal
Stair Step Design for
Ease of Wiring / Visibility
Consistent Power
Wiring with Jumpers
Maximum I/O
Follows Module
Density
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 4
FLEX 5000™ I/OFlexibility in Design and Maintenance
Simplified System Design and Maintenance
Z-Axis RemovalRemovable
Terminal Block
On-Line Addition*
& RIUP
Easy Terminal
Base Selection
Simple Plug-in
Shielding TB
Current Sourcing -
Analog
One to One TB
Mapping
TB3, TB3I, TB3W,
TB3T, TB3AC, TB32
Per Channel CJC,
Remote CJC
support
Screw and
Spring/Push-in TB
Options
On-line Addition for Standard modules only
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 5
FLEX 5000™ I/OFlexible Mounting Options
Mount the I/O to Meet Application Requirements
Certifications available at release
Horizontal or Vertical
XT for G3
-40 °C…70 °C Standard
-1000…2000 m Altitude
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 6
FLEX 5000™ I/OComparison to FLEX™ I/O
Same DIN Rail
Footprint as FLEX I/O
Maximum Wiring
Consistency
Increased Capacity &
System Performance
FLE
X 5000™
I/OF
LEX
™ I/O
FLEX 5000™ I/O FLEX 5000™ I/OFLEX 5000™ I/O
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 7
FLEX 5000™ I/OEverything is in the Channel
Control and Configure at the Channel Level
Configuration
Standard Data Structures
Per Channel selection
Scaling & Alarming on
Module
Protection &
Diagnostics
Electronic Fusing,
Overvoltage, Overload,
Reverse Polarity
Power, Temperature,
Open Wire, Short Circuit
Time Stamping
with PTP
I/O COS
Diagnostics
Events
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 8
FLEX 5000™ I/OIntegrate Safety up to SIL 3
Designed for
Fail-safe Applications
CIP™ Safety Modules
Single channel
SIL 3 /PLe/Cat. 4
Integrated Control and Safety for the Process Industry
Simplify Safety
Implementation
Mix Standard and
Safety I/O on same I/O
bank
Full Range of
Modules
Digital, Analog, HART,
Temperature and
Frequency
*Available in Future Release
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 9
FLEX 5000™ I/OFlexible Network Topologies
DLR | Star | Linear | PRP*
Copper or SFP Fiber
Ports*Scheduled for December 2018
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 10
Digital I/O
≤ 100 µs screw to backplane
200us RPI Support
Counter Functionality
Input Events
Scheduled Output
≤ 1 ms S2S Response Time*
Analog I/O
≤ 2 ms screw to backplane
200us RPI Support
16 bits Resolution
Alarms and Scaling
Current Sourcing
≤ 5 ms S2S Response Time*
Universal Analog Input
FLEX 5000™ I/OHigher Performance – Standard I/O
*Under test conditions
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 11
Safety Digital I/O
~4 ms Safety Reaction Time
2 ms RPI Support
Single Channel SIL 3/PLe/Cat. 4
Support Low, High, Continuous
Demand
Safety Analog I/O
~10 ms Safety Reaction Time
2 ms RPI Support
16 bits Resolution
Single Channel SIL 3/PLe/Cat. 4
Channel-to-Channel Isolation
HART V7 Support
Configurable Safety State
FLEX 5000™ I/OWide Range and Flexible – Safety I/O*
*Available in Future Release
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 12
Smart.Automation system with
intelligence that just works.
Productive.Simple integrated development resulting in improved
real-time operations and expedited maintenance.
Secure.Respond to your process
faster with intelligent control.
Improve real-time operations with
enhanced device integration.Safeguard your assets
and protect your brand.
FLEX 5000™ I/ODesigned for The Connected Enterprise
Diagnostics
Premier HART Integration
Enhanced Asset Data
On-Line Maintenance
Device Health
System Topology
Birth Certificates
Secure Boot
Implicit Protection
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 13
FLEX 5000™ I/ORelease Schedule
Standard
Catalog Description
5094-AENTR EtherNet/IP Adapter RJ45 8 I/O
5094-AEN2TR EtherNet/IP Adapter RJ45 16 I/O
5094-IB16 16 Point Digital Input
5094-OB16 16 Point Digital Output
5094-OW8I 8 Channel Relay Output Isolated
5094-IF8 8 Channel Analog Input
5094-IY8 8 Channel Universal Analog Input
5094-OF8 8 Channel Analog Output
5094-HSC 2 Channel High-Speed Counter
SIL 3 Safety
Catalog Description
5094-IB16S 16 Point Digital Input Safety
5094-OB16S 16 Point Digital Output Safety
5094-OW4IS 4 Channel Relay Output Isolated Safety
5094-IF4IHS4 Channel Analog Input Isolated HART
Safety
5094-OF4IHS4 Channel Analog Output Isolated HART
Safety
5094-IRT8S 8 Channel RTD/Thermocouple Safety
5094-IJ2IS 2 Channel Isolated Frequency Safety
All catalogs are available in Extreme Environment (XT) variant for G3 compliance
Standard
Catalog Description
5094-AENSFPRXT EtherNet/IP Adapter SFP w XT
5094-AEN2SFPRXT EtherNet/IP Adapter SFP w XT
5094-IB32 32 Point Digital Input
5094-OB32 32 Point Digital Output
5094-OB82A 8 Point Digital Output 2 Amp
5094-IA16 16 Channel AC Input
5094-OA16 16 Channel AC Output
5094-IF8IH8 Channel Analog Input
Isolated HART
5094-OF8IH8 Channel Analog Output
Isolated HART
5094-IJ2I 2 Channel Isolated Frequency
Future ReleaseCY18
Specific dates to be advised
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 14
FLEX 5000™ I/OWhen to Consider FLEX 5000 I/O Versus FLEX I/O
Continue to attach FLEX™ I/O with ControlLogix® 5570 Architecture
FLEX I/O is ACTIVE and supports all generations of Logix5000™ controllers
Longevity letters are available, including description of lifecycle support
Attach FLEX 5000™ I/O with CompactLogix™ 5380/ControlLogix 5580 Standard or
Safety Architecture
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 15
Flexible Network Media
and Topologies
Rugged I/O Designed for
Process Control
Wide Range of Standard
and Safety Modules
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 16
Compact 5000TM I/O Modules
High performance
• Dual 1-Gb Embedded EtherNet/IP Ports
Power• Separate system power for better isolation
• Built-in power input with field power to I/O modules
Enhanced standard functions• Common data structures
• Change of State
• Immediate output
• Timestamping – 10 ms accuracy at 1 ns resolution
• Native simple counters
Local and distributed I/O for CompactLogix™ 5380Distributed I/O for ControlLogix® 5580
New in CY2017:• 120/240VAC Input and Output modules
• Additional density options for relay output (16-channel) and 24 VDC
output (8-channel)
• Small network adapter
New in Q1/Q2 CY2018:• Serial module
• Digital Safety I/O
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 17
5069-AENTR Overview
56mm 22mm 22mm 22mm 22mm 36mm
5069-AENTR AC In Digital
Out
AC Out Serial Relay Out
AENTR vs. AEN2TR - Comparison
• Slimmer Design
• No USB Port
• No SD Card for Module Configuration
• No Diagnostic Display Screen
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 18
Serial module : Release 1 features
5069-SERIAL : Generic ASCII/Modbus RTU & ASCII
Generic ASCII using tag base programming
Modbus Master communication
Up to 50 commands per port
Data mapped directly back to module tags
Reduce need to create complex programming
Modbus Slave communication
Up to 30 data per port
Quick configuration at AOP.
*Performance and features are preliminary, changes may happen
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 19
Chassis & Distributed I/ORockwell Automation® Platform Positioning
ControlLogix®
Chassis-based I/O
• I/O diagnostics for
detection of both
system and field-
side failures
• Electronic keying to
help prevent
replacement errors
• Wide range of
modules from high
performance to
process control
ArmorBlock®
On-Machine™ I/O
• IP67 rated
modules
• Reduces wiring
and panel space
• Quick connect for
daisy chaining
modules
• Analog, Digital,
specialty, machine
safety and IO-Link
options available
1719 Ex,
1715 RedundantIntrinsic Safety and High
Availability I/O
• 1719 Ex I/O for
hazardous area
locations
• 1715 Redundant I/O
provides
high availability for
ControlLogix
controllers
Compact I/O™,
Compact 5000™
Discrete Machine I/O
• High-performance
Compact 5000™ I/O for
CompactLogix™ 5380
and ControlLogix 5580
• High-density Compact
I/O™ for
CompactLogix™ 5370
POINT I/O™
Smart Machine
Distributed I/O
• Low-cost platform
with lower density
inputs and outputs
• Compact design
makes installation
easier
• Machine safety,
specialty and IO-
Link options
available
Dynamix™
Condition Monitoring
• Integrates machine
protection with your
standard
control system
• Dual Ethernet ports
supporting both
Linear and Device
Level
Ring topologies
FLEX™,
FLEX 5000™
Process Distributed I/O• High-performance
FLEX 5000TM I/O for
CompactLogix™ 5380
and ControlLogix®
5580
• High-channel density
on a distributed
platform
PUBLIC
Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 20
HMS Linking Devices
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 21
HMS Anybus DLR Linking Devices
DLR to Profibus - HMS-EN2PB-R
DLR to Modbus - HMS-EN2MB-R
DLR to Serial - HMS-EN2SE-R
All have integration with Studio 5000 Logix Designer through custom AOPs
Offloads PLC from having to perform additional calculations for protocol
converter modules
More cost efficient than an in-chassis solution
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 22
HMS Anybus DLR Linking Devices
PUBLIC
Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 23
PanelView™ 5000 Family of Operator InterfacesFeaturing Studio 5000 View Designer® Software
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 24
PanelView 5000 Major Releases through 2018*
Releases to Date
PanelView 5500 withView Designer
PanelView™ 5310 withv4 View Designer
July 2018
PanelView™ 5510
Dec 2018
v5 View Studio Designer
• All new EOI Platform
• For new applications
leveraging 5370 / 5480 /
5570 / 5580 controllers
• Advanced Development
Environment
• Enhanced levels of
productivity
• Addition to PanelView™
5000 family
• Targeted at mid-size and
smaller applications not
requiring a haz loc rating
• For new applications
leveraging 5370 / 5480 /
5570 / 5580 controllers
• New v4 features
• Replaces PanelView 5500
• Next Gen Hardware
featuring a dual core
processor
• Runs v4 and v5 + future
generation software
• For new applications
leveraging 5370 / 5480 /
5570 / 5580 controllers
• PanelView 5310 and
PanelView 5510 compatible
• Provides multi-controller
support for PanelView 5510
• Increased screen and alarm
count
• Logix tag-based alarms
• Recipe Management
* Future dates are tentative.
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 25
MODERN DESIGN
For mid-size and smaller applications
6”*, 7”W, 9”W, 12”W
1.46 GHz Processor, 1 Gb RAM, 4 Gb Flash
Runs v4 and newer View Studio software
Touch screen only with aluminum bezel
Single port Ethernet
DC power
Not C1D1* 6” unit to be AFC mid 2018
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 26
Specifications PanelView 5310 PanelView 5500* PanelView 5510*
Multi-Version Support(Ability to install and run multiple versions of
configuration software side by side)
Yes YesYes
Application Limits1 controller, 50 screens, 1000
alarms
1 controller, 100 screens, 1000
alarms
1 controller, 100 screens, 1000
alarms
Resize Application on
DownloadYes Yes
Yes
ControlLogix® Controller
CompatibilityControlLogix® 5570 (v27+) / 5580 (v29+)
CompactLogix™ Controller
CompatibilityCompactLogix™ 5370 (v27+) / 5380 (v29+) / 5480 (v31+)
PanelView 5000 Family Comparison
* Note: PanelView 5500 will receive a hardware upgrade and will be renamed PanelView 5510
Project Explorer contains the structure
of the project
Properties Pane helps configure
elements
Searchable Toolbox of pre-built elements
Canvas area used for creating screens
VIEW DESIGNERGraphic Explorer displays graphic
elements
10”
19”
+1000MORE
SCALABLE GRAPHICS
29
Comprehensive library of graphics in Studio 5000 View Designer®: shapes, common controls, equipment, ISO
and ISA symbols
Embedded animation and behavior: color and movement animation and control actions built into many objects
SVGs allow reusable screen content - automatically scale screen content as appropriate for the target terminal
Graphical objects are linked to controller objects
Typ
ical
HM
IP
anel
Vie
w
5500
ENHANCED GRAPHICS
DATA LOGGING Log data on the PanelView 5000 terminal and display that historical data on a trend
Up to 250 tags can be logged
Logs are stored in circular logs
Logs are stored on an SD card in the PanelView 5000
Logs can be exported in csv format to a USB flash drive using a
predefined Settings screen
HISTORICAL TRENDING No trend configuration is required to display logged data
If a trend trace is bound to a tag that is also logged, the trend will
automatically show historical data (if the trend is panned to a time where
no real-time data exists for that tag)
Trends show historical data immediately when the screen is displayed
EMULATOR CAPABILITY Emulator lets you test run a project without downloading to a physical
PanelView™ 5000 terminal
VNC SUPPORT The PanelView 5000 terminals use a built-in VNC server to
support a remote VNC client for monitoring and
troubleshooting
Passwords can be configured to allow full read/write access
or read-only access to only VNC client users who enter the
correct password
A new settings screen can be used at runtime to lock down
the PanelView 5000 to disallow VNC access or limit it to
read-only access if desired
A new system tag indicates if a VNC client is connected
LOAD FROM REMOVABLE MEDIA You can save a View Designer project as a runtime image .vpdr file
The runtime image file can be copied to a USB flash drive or an SD
card that can then be inserted into the PanelView 5000 terminal
A new settings screen on the PanelView 5000 can be used to select
the desired runtime image file and initiate a download to the terminal
Optionally, you can choose to use the “HMI to controller” path
configured as part of the runtime image file. Or, continue to use the
path configured in the existing project currently running on the
PanelView 5000
Makes it easier to send an updated project to a location where
you do not know the exact controller path
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 35
LANGUAGE SWITCHING Use a language switch command to switch to any of the languages in the project
The language switch will also switch the language strings from the Logix controller including
extended tag properties and alarm messages
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 36
HMI Button Control
HMIBC HMIButtonJog …
HMIBC
HMI Button Control
HMIBC HMIButtonJog …
HMIBC
HIGH-SPEED BUTTON CONTROL
Eliminate hardwired push buttons
Save the expense of the push buttons, wiring, I/O and labor
PUBLIC
Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 37
Product Selection Toolbox (PST)
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 38
Product Selection Applications/Capabilities
Selection/configuration assistance,
estimating, quoting, quote generation Design/validate IA systems, subsystems, networks
Product Selection and ConfigurationSystem Layout, Analyzing, & Sizing
Complete Rockwell Product Catalog and Configurators
IAB Mobile
MigrationsApp
Simplified mobile
version of IABMigrate from SLC to
CompactLogix/ControlLogix
Product Catalog App
RAISEConfigurator
Product configurator forRockwell & Encompass Products
Find replacements for non-RA/RA
Products
Configure modular control
system starters/load feeders on busbars
Automation BuilderSafety
(Could transition to our team
from Portfolio Marketing later in year)
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 39
IAB download @http://raiseinstall.rockwellautomation.com/pst-lite.html
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 40
IAB DVDs for install available from local Distributor
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 41
Released in November, 2017:
iPhone iOS 8 through iOS 11
Android phones and tablets versions 4.2 & above
Available since 2013:
iPad with iOS 8 through iOS 11
41
Released
Catalog App
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 42
Migrations App
Quickly migrate:
• SLC™ 500 to a ControlLogix® or a CompactLogix™ controller-based configuration
• PLC-5® to a ControlLogix® controller-based configuration
1. Specify current configuration by placing modules into chassis
2. App selects equivalent ControlLogix or CompactLogix hardware
3. App provides migration details & BOM in CSV and share via email
Released
www.rockwellautomation.com
PUBLIC
Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 43
Thank You!