inverter multi-split system air conditioners mhiaa is proudly sponsoring … · 2015. 8. 21. ·...
TRANSCRIPT
-
Multi SeriesInverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue
-
MULTI series Air Conditioners 2013
2 Multi SeriesInverter Multi-Split System Air Conditioners.
The ideal solution for air conditioning multiple rooms
-
A home typically has many areas such as bedrooms, living spaces and study rooms. Therefore, to provide total comfort for your home, a multi-split system is recommended so each room can have its own air conditioner.
This can be achieved through a Mitsubishi Heavy Industries inverter multi-split system which delivers optimum heating or cooling for everyone, no matter where they are in the home and no matter what size the room may be. Silent, powerful, energy ef� cient and utilising advanced technologies, a Mitsubishi Heavy Industries inverter multi-split system is the solution for homes with many rooms and occupants.
3
WE
LCO
ME
-
MULTI series Air Conditioners 2013
4
CompactA Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home. One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your home but can be imperative when there is not much space available, for example, when installing outdoor units on balconies or verandahs.
Installation FlexibilityWith a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor units will be installed to optimise interior space and convenience. In addition, a maximum height difference of 25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service the rooms for multi storey homes.
Variety of Indoor UnitsThe indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette types in a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose the right type of indoor unit to complement the interior décor and match the size of each room.
*Please check model specifi cations as these pipe lengths and height differences do not apply to all models.
-
5
MU
LTI C
ON
CE
PT
Independent Control and ComfortEach indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such as the number of occupants or the way the room is used. With a range of comfort, air fl ow and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a room without affecting other ones. When a room is unoccupied you can switch off the unit to reduce ineffi cient energy use.
5 Year WarrantyWhen you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets. With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your home through the years.
-
MULTI series Air Conditioners 2013
66
Easy operationAll settings done by tapping touch screen panel
Operation mode
Cooling Dry Auto HeatingFan
Operation mode setting screen
The operation mode canbe selected by simply tappingthis button.
Setting temperature screen
You can select the desired temperature by tapping the ▲▼ button.
Main functions
Energy managementPeak cut timer • Automatic temperature set back • Weekly timer • Set ON/OFF timer by hour • Set ON/OFF timer by clock • Fan only operation • Sleep timer
ComfortIndividual fl ap control • High power operation • External ventilation ON/OFF • Warm up operation • Automatic fan speed • Temperature increment setting by 0.5ºC
ConvenienceLCD contrast setting • Back light setting • Filter clean sign • Control sound • Outdoor silent mode • Summer time setting • Home leave mode • Indoor & outdoor temperature display • Heating standby display • Defrosting operation display • Auto cooling/heating display • ºC/ºF display • Administrator settings • Room name setting
ServiceError code display • Operation data display • Next service data display • Contact company display • USB connection (mini-B)
-
7
CO
NT
RO
L & F
UN
CT
ION
S
Comfortable Functions
Automatic OperationThe air conditioner automatically selects from heating, cooling or dry operation.
"HI POWER" OperationThe unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.
Three "Hot" System‘Hot start’ enables the unit to begin heating operation quickly.‘Hot spurt’ is a fast heating system that works to increase the temperature setting by two degrees.‘Hot keep’ is used during the automatic defrost cycle to prevent cool air being circulated.These three operational control systems help ensure comfortable and efficient heating.
3HOT
St
art
Keep
Spurt
On TimerThis enables the operation to start a little earlier so that the room is near to the set temperature at ON time.
On Timer
Microcomputer-Operated DefrostingThis function automatically eliminates frost and helps minimize excessive operation in other modes.
MC
When removing the air inlet panel for internal cleaning or other reasons, open the grill by 65 degrees and then pull it to the side.
Detachable Indoor Air Inlet PanelThe air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed.
Detachable
Self-Diagnostic FunctionIf the air conditioner malfunctions an internal microcomputer runs a self diagnosis. Inspection and repair should be performed by authorized dealers.
DiagnosticSelf
Power blackout auto restart function records the operational status of the air conditioner immediately prior to being switched off by a power supply interruption. The unit automatically resumes operations in the mode and temperature set point after the power has been restored.
Auto Restart FunctionRestart
Auto
On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.
Back-up SwitchBack-upSwitch
Others
Economy ModeEconomyThe unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.
Dry OperationDRY The unit dehumidifies the room by intermittent cooling operation.
24-hour On/Off Programmable TimerBy combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.
24h Timer
Off TimerOFF TimerThe unit stops at the specified time.
Sleep ModeSleepThe room temperature is automatically controlled during the set sleep mode period ensuring that the room temperature will not get too hot or cold.
Convenience & Economy Functions
Maintenance & Prevention Functions
Comfortable Air Flow Functions
Slant forwardblowing
HEATING
Auto Flap ModeThe unit automatically selects the optimal angle whatever the operation mode.
Auto Flap Horizontal blowingCOOLING & DRY
Fuzzy Auto ModeAutomatically the unit determines its operating mode and temperature setting based on a fuzzy calculation and adjusts the inverter frequency.
You can choose the best heating or cooling pattern with the touch of a button.
3D Auto
Auto
Thick line : moves quicklyThin line : moves slowly
COOLING & DRY
HEATINGThick line : moves quicklyThin line : moves slowly
Air ScrollThe swing of the flap causes the air flow to spiral and the breeze to reach all corners of the room.
Air Scroll
Filter
Photocatalytic Washable Deodorizing FilterIt keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing the �lter to the sunlight.
Allergen Clear FilterThe �lter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.
SUNFilterSUNFilterSUNFilter
AllergenFilterAllergenFilterAllergenFilter
SWING FLAPFlap moves up and down continuously.
Memory FlapWhile the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts.
Memory
Up/Down Flap SwingThe Up/Down flap can be adjusted to the preferred angle anywhere between horizontal and perpendicular.
UP/DOWN
Lateral SwingThe louver swings from right to left automatically. Louver angle can be fixed in any desired position.
Lateral
Swing
You can set the left-right air �ow directions when you install the air conditioner near the side wall by remote controller operation.
Positioning of
installation
Positioning of Installation
Both lower and upper air outlets and upper air outlet can be selected. (SRF models only)
Air outletselection
Air Outlet Selection
With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.
Luminous
24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.
24h ION
Luminous Button
Natural Enzyme FilterEnzymes used in the �lter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the �lter and destroy them.
See details on page 2.
EnzymeFilter
EnzymeFilter
EnzymeFilter
Self CleanOperationSelf CleanOperationSelf CleanOperation
AllergenSystemAllergenSystemAllergenSystem
Functions.
-
MULTI series Air Conditioners 2013
8
Advanced Technology.
DC PAM inverterAn inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides superior performance.
High Ef� ciency.
CONVENTIONALINVERTER
CONVENTIONAL
Time
Room Temp.
ON
Less advanced technology does not addressthe ON/OFF cycle issue.
OFFRated Capacity
OFF
Set Temp.
Compressor(rps)
DC PAMINVERTER
DC PAMINVERTER
Time
Room Temp.
Even Temperature
ONRated Capacity
Utmost comfort and energy efficiency achievedwith large output power and control optimisation
Set Temp.
Compressor(rps)
PWMPAM
DC compressor motor
Mot
or E
ffic
ienc
y(%
)
Magnet Motor
Induction Motor
Low High
Improving
Improving
Revolution speedINVERTER
DCPAM
PowerActiveModule
New inverter control (Vector control)New Inverter Control has applied the new advanced technology of Vector control enabling:- • Smooth operation from low to high speed• Smooth Sine Voltage Wave form is achieved • Energy effi ciency has improved in low speed range
Propeller fanThe new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption.
Superior corrosion resistanceThe base of the outdoor unit is hot dipped to provide superior corrosion and scratch resistance.
Outdoor unitRedesigned by changing the � n con� guration from � at sheet to new M shape � n, ef� ciency has been improved. An optimum balance of heat transfer and air � ow has been achieved.
Silicon-coated PCBThe printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.
-
9
FE
ATU
RE
SAdvanced Technology.
All SRK, SRF
Applied models
SRK50/60ZJX, SRK-ZKSRF-50ZJX
Applied models
60dB 50dB 40dB 30dB 21dB
SRK20ZJX-S(In the Cooling Lo mode)
70dB
60dB
50dB
40dB
30dB
20dB
10dB
0dB
Comparison with fam
iliar noises in our eve
ryday life
Normal conversation
s
Quiet of�ce
In the library Late night
in a
typical suburban ar
ea
21dB
20m
30mMaximum height difference
Maximum pipe length
For the capacities under low temperature conditions, refer to technical manual.
50403020100-10-20
Heating
Cooling +46°C
+21°C
-15°C
-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX
Applied models
All SRK, SRF, SRR, FDTC
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
All SCM-appearance may varyAll SRK, SRFApplied models
SRK50/60ZJX, SRK-ZKSRF-50ZJX
Applied models
60dB 50dB 40dB 30dB 21dB
SRK20ZJX-S(In the Cooling Lo mode)
70dB
60dB
50dB
40dB
30dB
20dB
10dB
0dB
Comparison with fam
iliar noises in our eve
ryday life
Normal conversation
s
Quiet of�ce
In the library Late night
in a
typical suburban ar
ea
21dB
20m
30mMaximum height difference
Maximum pipe length
For the capacities under low temperature conditions, refer to technical manual.
50403020100-10-20
Heating
Cooling +46°C
+21°C
-15°C
-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX
Applied models
All SRK, SRF, SRR, FDTC
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
All SCM-appearance may vary
All SRK, SRF
Applied models
SRK50/60ZJX, SRK-ZKSRF-50ZJX
Applied models
60dB 50dB 40dB 30dB 21dB
SRK20ZJX-S(In the Cooling Lo mode)
70dB
60dB
50dB
40dB
30dB
20dB
10dB
0dB
Comparison with fam
iliar noises in our eve
ryday life
Normal conversation
s
Quiet of�ce
In the library Late night
in a
typical suburban ar
ea
21dB
20m
30mMaximum height difference
Maximum pipe length
For the capacities under low temperature conditions, refer to technical manual.
50403020100-10-20
Heating
Cooling +46°C
+21°C
-15°C
-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX
Applied models
All SRK, SRF, SRR, FDTC
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
All SCM-appearance may vary
All SRK, SRF
Applied models
SRK50/60ZJX, SRK-ZKSRF-50ZJX
Applied models
60dB 50dB 40dB 30dB 21dB
SRK20ZJX-S(In the Cooling Lo mode)
70dB
60dB
50dB
40dB
30dB
20dB
10dB
0dB
Comparison with fam
iliar noises in our eve
ryday life
Normal conversation
s
Quiet of�ce
In the library Late night
in a
typical suburban ar
ea
21dB
20m
30mMaximum height difference
Maximum pipe length
For the capacities under low temperature conditions, refer to technical manual.
50403020100-10-20
Heating
Cooling +46°C
+21°C
-15°C
-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX
Applied models
All SRK, SRF, SRR, FDTC
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
All SCM-appearance may vary
All SRK, SRF
Applied models
SRK50/60ZJX, SRK-ZKSRF-50ZJX
Applied models
60dB 50dB 40dB 30dB 21dB
SRK20ZJX-S(In the Cooling Lo mode)
70dB
60dB
50dB
40dB
30dB
20dB
10dB
0dB
Comparison with fam
iliar noises in our eve
ryday life
Normal conversation
s
Quiet of�ce
In the library Late night
in a
typical suburban ar
ea
21dB
20m
30mMaximum height difference
Maximum pipe length
For the capacities under low temperature conditions, refer to technical manual.
50403020100-10-20
Heating
Cooling +46°C
+21°C
-15°C
-15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX
Applied models
All SRK, SRF, SRR, FDTC
SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX
All SCM-appearance may vary
Live Bacteria Count on Measured Test Pieces
Test Pieces 1) Products with Antimicrobial and Antifungal Treatment
TestedContaminant Measurement Test Pieces
Bacteria Count Per Test PieceMeasurement 1 Measurement 2 Measurement 3
Escherichia coli IFO 3972 coli
Aspergillusniger
Staphylococcusaureus
Immediately after contact
After 24 hrs at 35°C
Not treated 1.9 x 105
-
MULTI series Air Conditioners 2013
10 3D AUTO Vertical + Horizontal AIR SCROLL.
SRK-ZJX, SRK-ZJ
SRK63/71/80ZK, Manual Setting only
Applied models
3D AUTO
Swing
Vertical Swing
Horizontal Air Scroll 8 Direction Swing
1 2 3 4
8 7 6 5
Swing Spot Wide
3
4
2
1
Cool Shower
Cool Shower
Floor Heating
Floor
Swing
Swing
Swing
Hi-Power (Quick)
Wide Swing (Every Corner)
Center (Long)
Wide-Air (Equal)
3 motors make 3 independent controls3 motors make 3 independent controls
Programmed air distribution
SRK-ZJX, SRK-ZJ
SRK63/71/80ZK, Manual Setting only
Applied models
3D AUTO
Swing
Vertical Swing
Horizontal Air Scroll 8 Direction Swing
1 2 3 4
8 7 6 5
Swing Spot Wide
3
4
2
1
Cool Shower
Cool Shower
Floor Heating
Floor
Swing
Swing
Swing
Hi-Power (Quick)
Wide Swing (Every Corner)
Center (Long)
Wide-Air (Equal)
3 motors make 3 independent controls3 motors make 3 independent controls
Programmed air distribution
SRK-ZJX, SRK-ZJ
SRK63/71/80ZK, Manual Setting only
Applied models
3D AUTO
Swing
Vertical Swing
Horizontal Air Scroll 8 Direction Swing
1 2 3 4
8 7 6 5
Swing Spot Wide
3
4
2
1
Cool Shower
Cool Shower
Floor Heating
Floor
Swing
Swing
Swing
Hi-Power (Quick)
Wide Swing (Every Corner)
Center (Long)
Wide-Air (Equal)
3 motors make 3 independent controls3 motors make 3 independent controls
Programmed air distribution
SRK-ZJX, SRK-ZJ
SRK63/71/80ZK, Manual Setting only
Applied models
3D AUTO
Swing
Vertical Swing
Horizontal Air Scroll 8 Direction Swing
1 2 3 4
8 7 6 5
Swing Spot Wide
3
4
2
1
Cool Shower
Cool Shower
Floor Heating
Floor
Swing
Swing
Swing
Hi-Power (Quick)
Wide Swing (Every Corner)
Center (Long)
Wide-Air (Equal)
3 motors make 3 independent controls3 motors make 3 independent controls
Programmed air distribution
3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air � ow controls.The air� ow is uniform, quiet and reaches at long distance from the indoor unit.
Programmed 3D AUTOAutomatic control of air � ow volume and air � ow direction enables comfortable air conditioning of the entire room. In cooling operation, cooled air � ows directly to the ceiling not directly onto the occupants of the room. The comfort cooled air � ow comes down from the ceiling like a soft shower.In heating operation, warm air � ows to the � oor directly and spreads along the � oor. The concentration of the warm air at � oor level increases comfort.
Manual SettingIndividual control of right and left louver enables air � ow direction from the right and the left side of the unit, setting the most preferable air � ow direction and determining whether direct air � ow is required or not.
-
11
FE
ATU
RE
SJet air scroll long reach & silent air � ow.
We used the same aerodynamic analysis technology as used in developing jet engines.CFD (computational � uid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The air� ow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The air� ow is uniform, quiet and reaches a long distance from the indoor unit.
New louver The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air � ow volume, it has improved controllability of the right to left swing function.
Fast SlowColors in the �gure show the air speed.
Aircraft technology was used in the design of the air conditioner’s airflow system
SRK71ZK(in cooling operation)
17m15m
SRK50/60ZJX(in cooling operation)
powerful
Newprevious
80% increased
Newprevious
80% increased
Positioning of InstallationYou can set the left-right air � ow directions when you install the air conditioner near the side wall by remote controller operation.
Long Reach Air FlowThe jet technology enables powerful air� ow ideal for large living areas and commercial premises, increasing your comfort.
-
MULTI series Air Conditioners 2013
12 Clean Air.
Catching Allergen on the Filter
AIR Purify
Cooling OperationTo make condensing water.
Heating OperationTo give moisture to the Filter to inactivate allergen
Self-Clean OperationTo dry up the indoor unit
Self Clean OperationThe ‘self clean operation’ is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.
Allergen Clear SystemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.
Generates the same amount of negative ions as a forest environment
24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.
The air in your room is kept fresh
Allergen clear systemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.
After one weekwithout self clean opration
After one weekwith self clean opration
First in the world20 of Patent Pending
Stop run 2hrs
Normaloperation
Cleanoperation
Shuts off automatically
Situation of mold after one week
Situation of mold after one week
Fungal mycelia expand.
The spore of mold doesn't germinate.
When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”
Fungal mycelia
Spore of mold
Spore of mold
Stop run 2hrs
Normaloperation
Cleanoperation
Shuts off automatically
Situation of mold after one week
Situation of mold after one week
Fungal mycelia expand.
The spore of mold doesn't germinate.
When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”
Fungal mycelia
Spore of mold
Spore of mold
Stop run 2hrs
Normaloperation
Cleanoperation
Shuts off automatically
Situation of mold after one week
Situation of mold after one week
Fungal mycelia expand.
The spore of mold doesn't germinate.
When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”
Fungal mycelia
Spore of mold
Spore of mold
-
13
FE
ATU
RE
S
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
CouplingCell wall
Filter �ber
Enzyme EnzymeBacterium
Powerful sterilizing effect
Enzyme's sterilizing mechanism
Sterilization Mechanism
-COOH
H2N-
Protein structure of allergen
Urea Enzyme
A molecule is decomposed
Slack of high order structure Reduction in a molecule
Inac
tivat
ion
rate
(%)
100
50
0
83.5%93.6%
72.7%83.5%
99.9% 99.0%
Rate of inactivation against allergens collected on the �lter
House dust mite*1 *1 *2 *2 *3 *3
A species of mite Cedar pollen Epithelium of cat Virus i Virus p
Photocatalytic Washable Deodorizing Filter
Allergen Clear Filter
Filter Indoor Unit
Used in models
*1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145
Air
�o
w
Conventional Filter Enzyme Filter
Analysis ZoneAnalysis Zone
Natural Enzyme Filter
SRF-ZJXSRK-ZKSRK-ZJX
1pc
-
1pc
SRK-ZJ
1pc
-
1pc
-
1pc
1pc
1pc
-
1pc
First in the world
Allergen clear � lterThis is the original and only technology to control the temperature and humidity for inactivating allergens
Enzyme + Urea deactivates allergens and kills bacteriaThe allergen clear � lter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens but some bacteria, moulds and viruses. Even if allergen, mould, virus or bacteria � y off the � lter they are deactivated so the air in your room is kept fresh.
Natural enzyme � lter Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds (Cat hair, dust mite, pollen etc.)
Enzyme � lterThe enzymes used in these � lters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the � lter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it.
Photocatalytic washable deodorizing � lterThe deodorizing ability of this filter can be easily restored simply by cleaning and exposing to sunlight
This � lter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This � lter maintains its deodorizing effect even after many repeat uses.
-
MULTI series Air Conditioners 2013
14 Ceiling Concealed Type.
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-TC-24W-ER
SRR25~60VF
Ceiling concealed type (SRR)
Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S
455
253
325.4
67035 35
515
3030
(Sus
pens
ion b
olts p
itch)
(Suspension bolts pitch)
Control Box
D
E
D
C
B
Suspension bolts
Drain piping
Liquid piping
VP166.35 1 4" Flare
Model
Gas pipingA
Symbol
12.7 1 2"
Content
SRR25ZJ-S,
9.52 3 8"
SRR50ZJ-S,
M8
Flare Flare
35ZJ-S 60ZJ-S
E Power supply intake 35
Option
Wired remote controllerWireless remote controller
120 196015
017.3
Unit:mm
150
13575
38
Terminal block
Air inlet
Air outlet B
AC
FIG.B
Note 1 The model name label is attached on the lid of the control box.
2 It takes the interface kit SC-BIKN-Eto connect the wired remote controller.
236
FIG.A
8- 2.8Holes for tapping screws 4
7.501047
230
11.2
10522090220105
4117
019
30
100540100
5214
830
174.
430
.3
70318.5 18.5
FIG.A(Air inlet from lower)
In case of filter guide installed(normal condition)
6-M4For hanger plate
177
21
4847528
670
2012
0
32
4040
35 35
FIG.B(Air inlet from rear)
In case of filter guide installed(option)
9- 2.8Holes for tapping screws 4
Holes for tapping screws 4
710
10 24
168 168 168 168
160
40
190
15
15 15
1113
1024
5- 3.3( Mark only)
In case of filter guide taken off
11- 2.8Holes for tapping screws 4
710
168 168 168 168
69423
10 10
23
2424
2080
8040
150
15 15
203.
711
.3
In case of rear panel taken off
Standard Equipment
-
15
PR
OD
UC
TS
Ceiling Cassette.
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
RCN-TC-24W-ER
wireless remote control
Fits into standard 600 x 600 ceiling
Previous(Cooling/Heating)
New(Cooling)
New(Heating)
36
35
34
33
32
31
30
29
28
27
26
25
(dB)
35dB
30dB
32dB
5dBDown
3dBDown
Flexible hose
248mm600mm
FDTC25~60VF
OA OAPanel
300mm
Ceiling surface
Indoor Unit FDTC
OA Spacer
Joint Duct
RC-E5RC-EX1A RCH-E3
Wired Remote Control
Wireless Remote Control
RCN-TC-24W-ER
Taking outside air insideOA Spacer TC-OAS-E (option)Joint Duct TC-OAD-E (option)
Utilizing OA spacer which comes as optional equipment, outside air can be taken inside.
Using 1 joint duct: OA comes up to 1.3m3/min.Using 2 joint ducts: OA comes from 1.3 to 2.6m3/min.
Quiet operation(Sound Pressure level in the Lo mode)
“CLEARER”air fl owNew shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains
Easy installation For wireless control simply insert the infrared receiver kit on a corner of the panel
Compact and convenient 600mm drain pumpDrain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit.It allows a piping layout with a high degree of freedom depending on the installation location.
600 x 600 ceilingIndoor unit size (W:570 x D:570) brings easy installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable for 600 x 600 ceiling. Height is one of the industry's lowest level at 248mm and weight is 16.5kg only.
-
MULTI series Air Conditioners 2013
16 Floor Standing.
Right
Left
Rear
Left rear
Left downward
Downward
Right
Left
Rear
Left rear
Left downward
Downward
Right
Left
Rear
Left rear
Left downward
Downward
Right
Left
Rear
Left rear
Left downward
Downward
Sophisticated design With a classy semi fl at front panel in chic white, this series fi ts in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, � oor standing or behind gallery installation is available.
Auto air outlet selectionHeating operation: When both lower and upper outlets operation and the Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at � oor level.
Cooling operation: When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner.
Easy installation Piping and drain hose connection can be selected out of 6-directions.
Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.
Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.
SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-SSRF25~50ZJX
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-TC-24W-ER
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-TC-24W-ER
-
PR
OD
UC
TS
17
Ceiling Concealed Type Medium Static.
Low profi le The height of FDUM50 model is only 280mm.
600mm drain pumpDrain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.
Improved servicing Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance is available from the right side or from beneath.
FDUM50VF
RC-E5RC-EX1A
Wired
RCH-E3 RCN-KIT3-E
WirelessRemote control (Option)
280
Flexible hose
less than 600mm
FDUM50VF
RC-E5RC-EX1A
Wired
RCH-E3 RCN-KIT3-E
WirelessRemote control (Option)
280
Flexible hose
less than 600mm
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-KIT3-E
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-KIT3-EFDUM50VF
RC-E5RC-EX1A
Wired
RCH-E3 RCN-KIT3-E
WirelessRemote control (Option)
280
Flexible hose
less than 600mm
Maintenance hole
Pipe
Fan unitUnit
Service space
FDUM50VF
-
MULTI series Air Conditioners 2013
18 Ceiling Suspended.
Wireless remote control
RCN-E-E
RC-E5
Wired remote control
RCH-E3
Wireless remote control
RCN-E-E
RC-E5
Wired remote control
RCH-E3
Rear
Right
Up
Height250mm
Rear
Right
Up
Height210mm
Easy installationIncreased freedom of a piping layoutThe refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.
Compact and modern designAll models � t compactly on the ceiling. Height is 210mm. Elegant, modern design featuring rounded edges gives the room a comfortable atmosphere.
FDEN50VF
-
19
PR
OD
UC
TS
Control Options.
Wired Remote Control Wireless Remote Option Super Link Network
Model Interface Wired Remote Control Infrared Kit Interface Wired Remote Control
SRK**ZJ-S
SC-BIKN-E
Options RC-EX1A RC-E5 RCH-E3
Not requiredSC-BIKN-E
SC-ADNA-EOptions RC-EX1A RC-E5 RCH-E3
SRK**ZJ-S1
SRK**ZJX-S
SRK**ZJX-S1
SRK71ZK-S
SRF**ZJX-S
SRF**ZJX-S1
SRR**ZJ-S
FDUM50VF
Not required
RCN-KIT3-E
SC-ADNA-EFDTC**VF RCN-TC-24W-ER
FDEN50VF RCN-E-E
CnT terminal is equipped
XR5
CnT
XR1~4 : DC12v XR5 : 220~240V
XR3
XR1
XR2
XR4
XR5
XR1
XR2
XR3
XR4
output1 (run)
output2 (heat)
output3 (comp on)
output4 (alarm)
common
Powersource
in put
Remote surveillance system
Card key on-off
HOTEL
HO
TE
L
Refrigerant Pipe Length Limit - The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum
height difference for the outdoor units are as shown below.
length for one indoor unittotal length for all roomslower installation spot of the indoor unit (A)upper installation spot of the indoor unit (B)maximum height difference of the indoor units (C)precharged to refrigerant pipe length
heightdifference
under 25munder 70munder 20munder 20munder 25m
40m
B
A
C
SCM40ZJ-S SCM50/60ZJ-S SCM71/80ZJ-S
B
A
C
SCM100ZJ-S
under 25munder 30munder 15munder 15munder 25m
30m
under 25munder 40munder 15munder 15munder 25m
40m
SCM40ZJ SCM50/60ZJ SCM71/80ZJ
under 25munder munder munder munder m
m
under 25munder munder munder munder m
m
SCM100ZJ SCM125ZJ
B
A
C
B
A
CB
A
C
SCM125ZJ-S
Maximum refrigeration pipe run metres SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100/125ZJ
length for one indoor unit 25
total length for all rooms 30 40 70 90
height difference
lower installation spot of the indoor unit (A)15 20
upper installation spot of the indoor unit (B)
maximum height difference of the indoor units (C) 25
pre charged to refrigerant pipe length 30 40 50
CnT terminal is equiped
-
MULTI series Air Conditioners 2013
20 Inverter Multi-Split System.
Wall mounted type SRK Ceiling concealed type SRR 4way ceiling cassette type FDTC
Floor type SRF Ceiling suspended type FDEN
Duct connected type FDUMDuct connected type FDUM
SCM-ZJThe multi system allows a single outdoor unit to service up to six indoor units.
Individual refrigerant circuit for each indoor unit
Outdoor Unit
Floor type SRF
SCM40ZJ-S1 / SCM50ZJ-S1SCM60ZJ-S1 SCM71ZJ-S1 / SCM80ZJ-S1 SCM100ZJ-S1/ SCM125ZJ-S1
-
PR
OD
UC
TS
21
SCM
40ZJ
-SSC
M50
ZJ-S
1SC
M60
ZJ-S
1SC
M71
ZJ-S
1SC
M80
ZJ-S
1SC
M10
0ZJ-
S1SC
M12
5ZJ-
S1
2 Ro
oms
2~3
Room
s2~
4 Ro
oms
4~5
Room
s4~
6 Ro
oms
Pow
er S
uppl
yOu
tdoo
r1
Phas
e 23
0V 5
0Hz
Rate
d Ca
paci
ty
Cool
ing
T1kW
4.0(
1.8~
5.9)
5.0(
1.8~
7.1)
6.0(
1.8~
7.5)
7.1(
1.8~
8.8)
8.0(
1.8~
9.2)
1012
.5
Heat
ing
H1kW
4.5(
1.4~
6.9)
6.0(
1.4~
7.5)
6.8(
1.5~
7.8)
8.6(
1.5~
9.4)
9.3(
1.5~
9.8)
1213
.5
Elec
tric
al In
put
Cool
ing
T1kW
0.84
1.
08
1.43
1.
74
2.16
2.
863.
9
Heat
ing
H1kW
0.90
1.
31
1.51
2.
00
2.26
2.
933.
25
EER
Cool
ing
T14.
76
4.63
4.
20
4.08
3.
70
3.5
3.21
COP
Heat
ing
H15.
00
4.58
4.
50
4.30
4.
12
4.1
4.15
Curr
ent
Cool
ing
T1A
3.7
4.7
6.5
7.6
9.4
12.4
17
Heat
ing
H1A
45.
86.
88.
810
12.8
14.1
Rec
Circ
uit B
reak
erA
25A
Soun
d Po
wer
Lev
el (J
IS C
9612
)Co
olin
g (O
utdo
or)
dB (A
)60
6263
6566
6869
Heat
ing
(Out
door
)dB
(A)
6265
6566
6671
72
Exte
rnal
Dim
ensi
ons
(HXW
XD)
mm
640X
850X
290
750X
880X
340
945X
970X
370
Net w
eigh
tOu
tdoo
rkg
4748
4962
92
Refr
iger
ant P
ipin
g
Liqu
id L
ine
mm
Ø6.3
5 X
2Ø6
.35
X 3
Ø6.3
5 X
3Ø6
.35
X 4
Ø6.3
5 X
4Ø6
.35
X 5
Ø6.3
5 X
6
Gas
Line
mm
Ø9.5
2 X
2Ø9
.52
X 3
Ø9.5
2 X
3Ø9
.52
X 4
Ø9.5
2 X
4Ø9
.52
X 5
Ø9.5
2 X
6
Unio
nm
m(Ø
9.52
Ø12
.7) X
1(Ø
9.52
Ø12
.7) X
2(Ø
9.52
Ø12
.7) X
2(Ø
9.52
Ø12
.7) X
2(Ø
9.52
Ø12
.7) X
2(Ø
9.52
Ø12
.7) X
2
Conn
ectio
n M
etho
dFl
are
conn
ectio
n
Refr
iger
ant R
410A
Volu
me
kg2.
02.
53.
156
Pre-
Char
ged
30 m
trs
40 m
trs
50 m
trs
Indo
or U
nit C
ombi
natio
n
SRK*
ZJS/
S1
kW
2.0,
2.5,
3.5
2.0,
2.5,
3.5,
5.0
2.0,
2.5,
3.5,
5.0
SRK*
ZJX
2.0,
2.5,
3.5
2.0,
2.5,
3.5
2.0,
2.5,
3.5
2.0,
2.5,
3.5
SRK*
ZJX-
S15.
05.
0,6.
05.
0,6.
0
SRK*
ZK-S
7.1
SRF*
ZJX
2.5,
3.5
2.5,
3.5
2.5,
3.5
SRF*
ZJX-
S15.
05.
05.
0
SRR*
ZJ2.
5,3.
52.
5,3.
5,5.
02.
5,3.
5,5.
0,6.
0
FDTC
*VD
2.5,
3.5
2.5,
3.5,
5.0
2.5,
3.5,
5.0,
6.0
FDUM
*VF
5.0
FDEN
*VF
5.0
Indo
or U
nit C
onne
ctio
n2
Units
2 to
3 U
nits
2 to
4 U
nits
4 to
5 U
nits
4 to
6 U
nits
Indo
or C
onne
ctio
n Ca
paci
tykW
4.0k
W to
6.0
kW4.
0kW
to 8
.5kW
4.0k
W to
11.
0kW
4.0k
W to
12.
6kW
4.0k
W to
13.
5kW
8.0
kW to
16k
W8.
0kW
to 1
9.5k
W
Note
s1
Rate
d da
ta is
mea
sure
d us
ing
SRK*
ZJX
indo
or u
nits
to m
atch
the
outd
oor u
nit c
apac
ity2
Curr
ently
ther
e is
no
ener
gy la
belli
ng s
tand
ard
for t
his
type
of p
rodu
ct
3 Th
e kW
out
put c
apac
ity, e
lect
rical
inpu
t, cu
rren
t and
reco
mm
ende
d ci
rcui
t bre
aker
are
indi
cate
d at
rate
d kW
out
put c
apac
ity. E
lect
rical
wor
k m
ust b
e ca
rrie
d ou
t by
a su
itabl
y qu
ali�
ed p
erso
n an
d co
mpl
y to
all
elec
tric
al
stan
dard
s an
d lo
cal r
egul
atio
ns.
-
MULTI series Air Conditioners 2013
22 Multi System Indoor Unit.
Series
SPECIFICATIONSItem Model
Cooling capacityHeating capacity
Sound power level
Sound pressure level
kWkW
dB(A)dB(A)dB(A)dB(A)
l/s
mmkg
mmmm
CoolingHeatingCoolingHeatingCoolingHeating
Liquid lineGas line
2.53.15558
Hi:41 Me:31 Lo:22Hi:41 Me:34 Lo:27
208-150-83216-166-125
15
ø 6.35
SRK25ZJX-S3.54.55859
Hi:43 Me:33 Lo:22Hi:42 Me:35 Lo:27
225-158-83233-183-134
SRK35ZJX-S5.05.86062
Hi:47 Me:40 Lo:27Hi:48 Me:40 Lo:33
225-183-133275-241-175
SRK50ZJX-S6.06.86262
Hi:51 Me:41 Lo:29Hi:48 Me:41 Lo:34
241-208-141283-250-183
SRK60ZJX-S
ø 12.7
SRK20ZJX-S2.02.55354
Hi:39 Me:30 Lo:21Hi:38 Me:33 Lo:25
191-133-83200-158-116
SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1
309X890X220
Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1
ø 9.52
*
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Exterior dimensions (HXWXD)Net weightClean �lter
Piping
OUTDOOR UNITS TO BE COMBINED
Air �ow Indoor
FUNCTIONComfortable Functions
Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral
SwingAuto
Positioning of
installation
Others
RestartAutoBack-up
SwitchLuminous
24h ION
Maintenance & Prevention Functions
MC DiagnosticSelf Detachable
AllergenFilterAllergenFilterAllergenFilter
SUNFilterSUNFilterSUNFilter
Self CleanOperationSelf CleanOperationSelf CleanOperation
Convenient & Economy FunctionsOn Timer
24h TimerDRY
OFF Timer SleepEconomy
SRK-ZJXHigh COP wall mount type
SRR-ZJCeiling concealed type
SPECIFICATIONS
SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-SModelCooling capacityHeating capacity
Sound power level
Sound pressure level
Air �ow Q’ty (Hi)
Exterior dimensions(HXWXD)Net weight
Piping
OUTDOOR UNITS TO BE COMBINED
kWkW
dB(A)dB(A)dB(A)dB(A)
l/s
mmkg
mmmm
CoolingHeatingCoolingHeatingCoolingHeating
2.53.45455
Hi:40 Me:35 Lo:29Hi:41 Me:38 Lo:31
142167
3.54.55657
Hi:42 Me:37 Lo:30Hi:43 Me:40 Lo:32
150183
5.05.86060
Hi:48 Me:42 Lo:33Hi:48 Me:45 Lo:36
175217
6.06.86363
Hi:51 Me:44 Lo:35Hi:51 Me:47 Lo:38
208250
230x740x455
ø 6.35ø 9.52
23
SCM40~125ZJ-S1
*
*
ø 6.35ø 12.7
22
SCM60~125ZJ-S1SCM50~125ZJ-S1
Liquid lineGas line
FUNCTIONComfortable Functions Maintenance & Prevention Functions
MC DiagnosticSelfSelf CleanOperationSelf CleanOperationSelf CleanOperation
Others
RestartAutoBack-up
SwitchLuminous
Convenient & Economy FunctionsOn Timer
24h TimerDRY
OFF Timer SleepEconomy
-
PR
OD
UC
TS
23
Multi System Indoor Unit.
FUNCTIONComfortable Functions Convenient & Economy Functions
On Timer24h Timer
Economy
DRY
OFF Timer SleepOthers
RestartAutoBack-up
SwitchLuminous
Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Air outlet
selection
Maintenance & Prevention Functions
MC DiagnosticSelf DetachableEnzymeFilter
EnzymeFilter
EnzymeFilter
SUNFilterSUNFilterSUNFilter
Self CleanOperationSelf CleanOperationSelf CleanOperation
SPECIFICATIONSModel
Cooling capacityHeating capacity
Sound power level
Sound pressure level
kWkW
dB(A)dB(A)dB(A)dB(A)
l/s
mmkg
mmmm
CoolingHeatingCoolingHeatingCoolingHeating
SRF35ZJX-S5.05.85858
Hi:46 Me:42 Lo:32Hi:47 Me:41 Lo:33
191-160-110200-166-126
SRF50ZJX-S3.54.55252
Hi:41 Me:34 Lo:28Hi:41 Me:36 Lo:31
153-130-106178-138-123
SRF25ZJX-S2.53.45151
Hi:40 Me:32 Lo:26Hi:40 Me:35 Lo:28
150-126-96175-136-110
Liquid lineGas line
600X860X23819
ø 6.35
*
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1
SCM40~125ZJ-S1 SCM50~125ZJ-S1
ø 9.52 ø 12.7
Exterior dimensions (HXWXD)Net weightClean �lter
Piping
OUTDOOR UNITS TO BE COMBINED
18
Air �ow Indoor
SRF-ZJXFloor type
SRK-ZJ-S1Wall mount type
Series
SPECIFICATIONSModel
Cooling capacityHeating capacity
Sound power level
Sound pressure level
kWkW
dB(A)dB(A)dB(A)dB(A)
l/s
mmkg
mmmm
CoolingHeatingCoolingHeatingCoolingHeating
Liquid lineGas line
2.53.25055
Hi:34 Me:28 Lo:21Hi:39 Me:31 Lo:24
131-100-83176-108-85
9.5
ø 6.35
SRK25ZJ-S/S13.54.05859
Hi:42 Me:32 Lo:22Hi:43 Me:37 Lo:25
168-106-83213-156-101
SRK35ZJ-S/S15.05.86161
Hi:46 Me:37 Lo:26Hi:45 Me:37 Lo:31
188-130-88225-170-125
SRK50ZJ-S/S1
ø 12.7
SRK20ZJ-S/S12.02.74952
Hi:33 Me:27 Lo:21Hi:36 Me:31 Lo:24
130-93-80163-105-83
SCM40~125ZJ-S1 SCM50~125ZJ-S1
294X798X229
Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1
ø 9.52
*
*
Exterior dimensions (HXWXD)Net weightClean �lter
Piping
OUTDOOR UNITS TO BE COMBINED
Air �ow Indoor
FUNCTIONComfortable Functions
Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral
SwingAuto
Positioning of
installation
Others
RestartAutoBack-up
SwitchLuminous
Maintenance & Prevention Functions
MC DiagnosticSelf Detachable
AllergenFilterAllergenFilterAllergenFilter
SUNFilterSUNFilterSUNFilter
Self CleanOperationSelf CleanOperationSelf CleanOperation
Convenient & Economy FunctionsOn Timer
24h TimerDRY
OFF Timer SleepEconomy
-
MULTI series Air Conditioners 2013
24 Inverter Multi Split System.
SRK-ZKWall mounted type
Series
SPECIFICATIONSItem Model
Nominal cooling capacityNominal heating capacity
Sound power level
Sound pressure level
kWkW
dB(A)dB(A)dB(A)dB(A)
CMM
mmkg
mmmm
CoolingHeatingCoolingHeatingCoolingHeating
SRK71ZK-S7.18.06061
Hi:49 Me:45 Lo:39 Ulo:26Hi:46 Me:43 Lo:38 Ulo:35
Hi:19.5 Me:17.5 Lo:14.0 Ulo:8.0Hi:21.5 Me:19.5 Lo:15.5 Ulo:14.0
318x1098x24815
Liquid lineGas line
Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1 6.35 15.88
*
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.
Exterior dimensions (HXWXD)Net weightClean �lter
Piping
OUTDOOR UNITS TO BE COMBINED
Air �ow
FUNCTIONComfortable Functions
Others
RestartAutoBack-up
SwitchLuminous
Maintenance & Prevention Functions
MC DiagnosticSelf DetachableConvenient & Economy Functions
On Timer24h TimerDRY
OFF Timer SleepEconomy
AllergenFilterAllergenFilterAllergenFilter
SUNFilterSUNFilterSUNFilter
Self CleanOperationSelf CleanOperationSelf CleanOperation
Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral
Swing
Air Scroll24h ION
SCM100/125ZJ-S1
FDEN-VFCeiling suspended
FDEN50VFItem ModelNominal cooling capacityNominal heating capacity
Sound pressure level
Air �ow
Exterior dimensions (HxWxD)Net weightAir �lter
Piping
OUTDOOR UNITS TO BE COMBINED
kWkW
dB(A)dB(A)CMMCMMmmkg
mmmm
CoolingHeatingCoolingHeating
5.05.8
Hi:39 Me:38 Lo:37Hi:39 Me:38 Lo:37Hi:11 Me:9 Lo:7Hi:11 Me:9 Lo:7
210x1070x69028
Pocket Plastic net x 2 (Washable)
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level:Cooling dB(A):46 Heating:46, Air �ow:13CMM
6.3512.7
Liquid lineGas line
SPECIFICATIONS
FUNCTIONComfortable Functions Comfortable Air Flow Functions
Auto Flap Memory UP/DOWNOthers
RestartAutoBack-up
Switch
Maintenance & Prevention Functions
MC DiagnosticSelfConvenient & Economy Functions
On Timer24h TimerDRY
OFF Timer Sleep
SCM50~125ZJ-S1
RC-E5 RCH-E3
Wired Remote Control Wireless Remote Control
RCN-E-E
-
PR
OD
UC
TS
25
Inverter Multi Split System.
FDTC-VF4way ceiling cassette type
FDTC25VF FDTC35VF FDTC50VF FDTC60VF
SPECIFICATIONS
Item Model
Nominal cooling capacityNominal heating capacity
Sound pressure level
Air �ow
Exterior dimensions(HXWXD)
Net weight
Piping
OUTDOOR UNITS TO BE COMBINED
kWkW
dB(A)dB(A)CMMCMMmmmmkgkg
mmmm
CoolingHeatingCoolingHeatingMain unitPanelMain unitPanelLiquid lineGas line
2.53.4
Hi:36 Me:32 Lo:29Hi:38 Me:33 Lo:29.5
Hi:9 Me:8 Lo:6.5Hi:9.5 Me:8.5 Lo:7
3.54.5
Hi:40 Me:36 Lo:30Hi:42 Me:35 Lo:32Hi:9.5 Me:9 Lo:7Hi:10 Me:9 Lo:8
5.05.8
Hi:42 Me:36 Lo:30Hi:42 Me:36 Lo:32Hi:11.5 Me:9 Lo:7Hi:11.5 Me:9 Lo:8
6.06.8
Hi:46 Me:39 Lo:30Hi:46 Me:39 Lo:32Hi:13.5 Me:10 Lo:7Hi:13.5 Me:10 Lo:8
248x570x57035x700x700
153.5
6.359.52
6.3512.7
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound level dB(A):25VF(Cooling:38 Heating:39), 35VF(Cooling:41 Heating:43), 40/50/60VF(Cooling:47 Heating:47), Air �ow:25VF(Cooling:10 Heating:10.5), 35VF(Cooling:11 Heating:11.5), 50/60VF(Cooling:13.5 Heating:13.5)
FUNCTIONComfortable Functions Comfortable Air Flow Functions
Auto Flap Memory UP/DOWNOthers
RestartAutoBack-up
Switch
Maintenance & Prevention Functions
MC DiagnosticSelfConvenient & Economy Functions
On Timer24h TimerDRY
OFF Timer Sleep
Fits into standard 600 x 600 ceiling
SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-TC-24W-ER
FDUM-VFDucted connected-low/middlestatic pressure
FDUM50VF
SPECIFICATIONS
Item Model
Nominal cooling capacityNominal heating capacity
Sound pressure level
Air �ow
Exterior dimensions (HxWxD)Net weightAir �lter
Piping
OUTDOOR UNITS TO BE COMBINED
kWkW
dB(A)dB(A)CMMCMMmmkg
mmmm
CoolingHeatingCoolingHeating
5.05.8
Hi:32 Me:29 Lo:26Hi:32 Me:29 Lo:26
Hi:10 Me:9 Lo:8Hi:10 Me:9 Lo:8
280x750x63529
Procure locally
*
The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
* Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level dB(A):Cooling:37 Heating:37, Air �ow:13CMM
6.3512.7
Liquid lineGas line
FUNCTIONComfortable Functions Others
RestartAutoBack-up
Switch
Maintenance & Prevention Functions
MC DiagnosticSelfConvenient & Economy Functions
On Timer24h TimerDRY
OFF Timer Sleep
Filter KITUM-FL1EF (option)
SCM50~125ZJ-S1
RC-E5RC-EX1A RCH-E3
Wired Remote Control Wireless Remote Control
RCN-KIT3-E
-
MULTI series Air Conditioners 2013
26 Dimension Outdoor Unit. Models SCM40ZJ-S, 45ZJ-S
Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places
secalp4x01MelohtlobrohcnAE
D
BAC
Service panel
Terminal block
E43
.5286.4
49.6
290
476203.1 510 136.9
1431
2.5
5012
13.5
340
640
15
850
100.3
42.7
124.1 34.6
2-16x12
211
42.7
2020
20
103.2
385.9 14.6
17.965
20
L1
L3Intake
No obstaclesService space
L2
Intake
Outlet
Minimum installation space
for electricalparts
100
600L2L3
L1
Examples of
100
Installation
Dimensions
Unit:mm
Models SCM71ZJ-S1, 80ZJ-S1
L1
L3Intake
L2
Intake
Outlet
100
600L2L3
L1
Examples of
100
Installation
Dimensions
Minimum installation space
DTerminal block
C
E
tnetnoClobmySA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places
secalp 4 x 01Meloh tlob rohcnAE
B
A
No obstaclesService space
for electricalparts
Unit:mm
1560
380
1941
8
73880150 580 150 26
340
2-R7.5
223
47.5
310
61
61
110.4
52
185 10
2475
0
214.4
5231
8.452
422.4
52
20
Model SCM125ZJ-S1
9.52 3 8" Flare
Content
C Pipe cable draw-out hole
D
E Anchor bolt hole
Drain discharge hole
Symbol
B
A Service valve connection gas side
M10 x 4places
20 x 3places
Service valve connection liquid side 6.35 1 4" Flare
L2L3
L1300150
OpenOpen150
500Open
3005
Examples of
Dimensions installation
L1
L3
Intake
Outlet
Intake
Minimum installation space
spaceService
L2
No obstaclesService space
for electricalparts
D580
76190
60
55
20
200
262.8 325
410
4037
040
20
Center of gravity
945
5211
5.2 219.2
5252
5252
531.2
427.2
323.2
5263
5.2
393
10
E
Center of gravity 26970
15 15
580
177
73
B
AC
Terminal block Rear panel
10170
Models SCM50ZJ-S1, 60ZJ-S1
Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places
secalp 4 x 01Meloh tlob rohcnAE
D
BAC
Service panel
Terminal block
E
L1
L3Intake
L2
Intake
Outlet
100
600L2L3
L1
Examples of
100
Installation
Dimensions
Minimum installation space
No obstaclesService space
for electricalparts
Unit:mm
43.5
286.4
49.6
136.9
1431
2.5
5012
13.5
340
640
15 100.3
42.7
Model SCM100ZJ-S1
9.52 3 8" Flare
Content
C Pipe cable draw-out hole
D
E Anchor bolt hole
Drain discharge hole
Symbol
B
A Service valve connection gas side
M10 x 4places
20 x 3places
Service valve connection liquid side 6.35 1 4" Flare
L2L3
L1300150
OpenOpen150
500Open
3005
Examples of
Dimensions installation
L1
L3
Intake
Outlet
Intake
Minimum installation space
spaceService
L2
No obstaclesService space
for electricalparts
D580
76190
60
55
20
200
262.8 325
410
4037
040
20
Center of gravity
945
5211
5.2 219.2
5252
5252
531.2
427.2
323.239
3
10
E
Center of gravity970
15 15
177
2658073
B
AC
Terminal block Rear panel
10170
SCM40ZJ-S
SCM71ZJ-S1 SCM80ZJ-S1
SCM125ZJ-S1
SCM50ZJ-S1 SCM60ZJ-S1
SCM100ZJ-S1
-
27
SP
EC
IFIC
ATIO
NS
-
Because of our policy of continuous improvement, we reserve the right to make changes in all speci� cations without notice. E&OE.
Australia: New Zealand: ABN 92 133 980 275 G.S.T. 105-673-620
Phone: 1300 138 007 Fax: 1800 644 329 Phone: 0800 138 007 Fax: 09 442 5346
NSW & Head Of� ce9C Commercial RoadKingsgrove NSW 2208PO Box 318 Kingsgrove NSW 1480
Victoria2/24 Lakeside DriveBurwood East VIC 3151
Queensland5/26 Flinders Parade North Lakes QLD 4509
Western AustraliaUnit 3A 2 Mulgul Rd Malaga WA 6090PO Box 667 Belmont WA 6104
AucklandUnit 2 100 Bush Road Albany 0632PO Box 300552 Albany 0632
www.mhiaa.com.au www.mhiaa.co.nz
MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044
Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).
ISO9001
BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 9001
Certi�cate number : JQA-0709
Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001.
ISO14001
BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 14001
Certi�cate number : JQA-EM0256
MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO., LTD.
Certi�ed ISO 9001Certi�cate Number : 04100 1998 0813
MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO.,LTD.
Certi�cate Number : 04104 1998 0813 E5
ISO 14001Certi�cate 04104 1998 0813 E5
MH
IAA
306_
MU
LTI 1
2_20
12
Before starting use
Heating performanceThe heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insuf� cient, use other heating appliances as well.
Indication of sound valuesThe sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.
Use in oil atmosphereAvoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.
Use in acidic or alkaline atmosphereIf this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.
Use in places with high ceilingsIf the ceiling is high, install a circulator to improve the heat and air � ow distribution when heating.
Refrigerant leakageThe refrigerant (R410A) used for Air conditioner is non-toxic and non� ammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.
Use in snowy areasTake the following measures when installing the outdoor unit in snowy areas.
Snow preventionInstall a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.
Snow pilingIn areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.
Automatic defrosting deviceIf the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The “Automatic defrosting device” will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.
Servicing the air-conditionerAfter the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.
Safety PrecautionsAir-conditioner usage targetThe air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.
Before useAlways read the “User,s Manual” thoroughly before starting use.
InstallationAlways commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and � res. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.
Usage placeDo not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, � ow or accumulate, or places containing carbon � bers could lead to � res.
Only persons that are quali� ed and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations.
MHIAA is proudly sponsoring Monika’s Doggie Rescue