Introduction to
the BRYAN
1
![Page 2: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/2.jpg)
2
Quality Construction Features• Standard Operating Parameters
Maximum Boiler Design Pressure All Models – 160 Psig
Maximum Boiler Design Temperature All Models – 210° F.
Gas pressure All Models - 14”w.c.min / 2# max
![Page 3: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/3.jpg)
3
Quality Construction Features• Standard Operating Parameters
Power Requirements TF150 & TF200 - 208-240/1/60vac TF250 & TF300 - 208-240/3/60vac
DC Motor Horsepower TF150 & TF200 - 1.4 H.P - 6 FLA TF250 & TF300 - 4.0 H.P - 16 FLA
![Page 4: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/4.jpg)
4
Quality Construction Features• Standard Operating Parameters
Minimum Entering Water Temperature 50°F.
Standard Relief Valve Settings 30#, 45#, 60# or 125#
Stack Type Category IV AL29-4C Material
High Altitude Firing 4% De-rate per 1,000ft above 2,000ft
5,000ft De-rate Example:
5,000ft-2,000ft=3,000ft
3,000ft/1,000ft=3
3x4%=12% de-rate
![Page 5: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/5.jpg)
5
Triple-Flex Water & Combustion Air Flow
![Page 6: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/6.jpg)
6
Quality Construction Features• Tubes
Size - 1½“ Nominal O.D. Reduced to 1”O.D. The reduction allows setting the tubes side by
side rather than staggering them as done in our current manufacturing process.
Flexible 8 Pass Design - Furnace Section 10 Pass Design - Convection Section Incorporated the traditional BRYAN standard
two flex tube design concept
![Page 7: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/7.jpg)
7
Quality Construction Features• Tubes
Material #316L Stainless Steel
End-Formed
• Single Side Tube Access BRYAN has incorporated single-sided boiler
access as standard on most of it’s boilers and this feature is maintained on the Triple-Flex.
![Page 8: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/8.jpg)
8
Triple-Flex TubesFurnace Convection End-Formed
![Page 9: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/9.jpg)
9
Quality Construction Features• Exterior Boiler Features
Suspended Jacket Frame Reducing Jacket Losses
Standard 16 Gauge Durable Powder Coated Finish Hammer Tone Grey Color Access Panels - Removable on Sides & Back Hinged Front Access Control Panel Door Replaceable Standard Sized Intake Air Filter
20”x25” Fiberglass Media
![Page 10: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/10.jpg)
10
Triple-Flex Access Panels
![Page 11: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/11.jpg)
11
Quality Construction Features• Interior Boiler Features
Three Combustion Gas Pass Sections One Furnace Section Two Convection Sections
Flue Collector Material #304L Stainless Steel – Top & Sides
Special Floor / Drain Pan Material AL6-XN Stainless Steel Highly Resistant to Corrosion
![Page 12: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/12.jpg)
12
Boiler Construction View (Access Side)
![Page 13: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/13.jpg)
13
Boiler Construction View (Opposite Side)
![Page 14: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/14.jpg)
14
Boiler Cut-Away View
![Page 15: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/15.jpg)
15
Quality Construction Features• Efficiency Enhancement Features
Fireside Heating Surface Minimum Nine (9) Sq. Ft. per BHP
Air Cooled Outer Jacket Pre-heats Combustion Air
High Efficiency Air-to-Air Exchanger Material - #3003 Aluminum
![Page 16: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/16.jpg)
16
Air-to-Air Heat Exchanger
![Page 17: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/17.jpg)
17
Air-to-Air Heat Exchanger
![Page 18: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/18.jpg)
18
Quality Construction Features• Gas Burner Manufactured by BRYAN
Forced Draft Hybrid Metal Fiber Type Turndown Ratio
TF150 & TF250 - 4:1 Turndown TF200 & TF300 - 5:1 Turndown
Sub 30 PPM Low NOx Sub 9 PPM with 10% De-rate
• Gas Valves Dual Motorized - Standard
Vent-less
![Page 19: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/19.jpg)
19
BRYAN Hybrid Metal Fiber Burner
![Page 20: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/20.jpg)
20
Quality Construction Features• Pressure Switches
High Gas Pressure Switch – Vent-less Low Gas Pressure Switch – Vent-less Pilot Low Gas Pressure Switch – Vent-less Burner High Air Pressure Switch Exchanger High Air Pressure Switch
• Flow Switches Combustion Air Flow Switch Water Flow Switch
![Page 21: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/21.jpg)
21
Quality Construction Features• Standard Operating Controls
Indicator Lights Power On – White Enabled – Green Fuel On – Amber Alarm – Red
Probe Type Low Water Cutoff with M/R 24 Hour Repeat Cycle Timer – via Sola
Control
![Page 22: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/22.jpg)
22
Quality Construction Features• Standard Operating Controls
Standard Tie-In Points Boiler Status – Fuel On - 120vac 75va General Alarm - 120vac 75va
Standard Terminals Enable / Disable Aux. Recycle Interlock
![Page 23: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/23.jpg)
23
Quality Construction Features• Standard Operating Controls
Boiler Pressure Gauge Boiler Temperature Gauge On/Off Switch Operator & Limit Controls via Sola Control Boiler Lock-out Reset Switch Fused Single Point Power Connection Control Circuit Transformer – 208-240vac to
120vac
![Page 24: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/24.jpg)
24
Boiler Control Center
![Page 25: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/25.jpg)
25
Quality Construction Features• Boiler Control Center
Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System
LCD Touch Screen Display Boiler Control Point Monitoring
Supply Water Temperature Stack Flue Gas Temperature Power Burner Operations
![Page 26: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/26.jpg)
26
Quality Construction Features• Boiler Control Center
Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System
Operating Status of: Firing Rate Combustion Blower Speed Boiler Set Point Flue Outlet Temperature
Alarms Displayed via Sola Display Flame Fail, Low Water, High Limit Low Gas Pressure, High Gas Pressure Air Flow, Pilot Fail and More
![Page 27: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/27.jpg)
27
Quality Construction Features• Boiler Control Center
Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System
Modify Operating Temperature Settings Accepts 4-20mA Signal From EMS / BMS Standard Enable / Disable Terminals Lead / Lag Control for Up to 8 Boilers ModBus Communications Protocol Temperature Input for either Outdoor Reset
or Header Temperature ( Sensor Optional) Input for Return Water Temperature (Sensor
Optional)
![Page 28: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/28.jpg)
28
Honeywell “SOLA” Control
![Page 29: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/29.jpg)
29
Honeywell “SOLA” ControlExamples of Low and High Firing Rates
Notice the Stack and Outlet Temperature
![Page 30: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/30.jpg)
30
Quality Construction Features• Optional Features Available
Reverse Construction Auxiliary LWCO
Probe Type – Mounted in Rear of Boiler Float Type – Mounted in Field in System Piping
Combustion Air Filter Housing with Flange Ducted Air Connection 20” x 25”
Neutralizer Kit
![Page 31: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/31.jpg)
31
PH Neutralizer Kit
![Page 32: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/32.jpg)
32
Triple-Flex Thermal Shock Warranty• Lifetime Non-Pro-Rated:
To Original Owner & Installation Covers Failure of Pressure Vessel
Upper and Lower Headers Tubes
When Due to Unequal Expansion, Often Described as “Thermal Shock”
![Page 33: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/33.jpg)
33
Triple-Flex Corrosion Warranty• Covers Failure Due to Corrosion from
Flue Gas Condensation: 10 Years
Upper and Lower Headers
5 Years Flexible Water Tubes Flue Collector
![Page 34: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/34.jpg)
34
Triple-Flex Limited Parts Warranty• Metal Fiber Burner Head:
24 Months From Date of Shipment
• Boiler, Burner & Controls: 12 Months From Date of Start-up or 18
Months From Date of Shipment, Whichever Occurs First
![Page 35: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/35.jpg)
35
![Page 36: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/36.jpg)
36
Key Features• Quality Construction
Special New Tubes Flexible Stainless Steel End-Formed
Boiler Efficiency Enhancement Minimum 9 sq. ft. of Heating Surface per BHP Air Cooled Jacket Pre-heated by Combustion Air Air-to-Air Exchanger
Flue Collector – 100% Stainless Steel
![Page 37: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/37.jpg)
37
Key Features• Quality Construction
Gas Burner By Bryan Hybrid metal fiber High Turndown Low NOx
Honeywell “ SOLA” Boiler Control Center Touch screen Burner / Boiler Operations Lead / Lag Outdoor Reset Communications
![Page 38: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/38.jpg)
38
Key Features• Guaranteed Efficiency
90 % Utilizing Standard Operating Water Temperatures: 160°F. Return & 180°F. Supply
• Greater Efficiency Efficiencies up to 98% by Utilizing Cooler
Operating Water Temperatures Example: 80°F. Return & 100°F. Supply
![Page 39: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/39.jpg)
39
• Guaranteed Efficiency
![Page 40: Introduction to the BRYAN 1. 2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum](https://reader030.vdocuments.us/reader030/viewer/2022032702/56649ca45503460f94964d18/html5/thumbnails/40.jpg)
40