introduction available cls cas 3 floodlights cas3 manual.pdf · 2010. 10. 6. · cls manualscls...

4
CLS Manuals CLS Cas 3 Luxeon III / K2 www.cls-led.com version 2.0 June 2009 www.cls-led.com - 1 - - 2 - CLS Cas 3 Luxeon III / K2 INTRODUCTION Thank you for choosing the CLS Cas 3 inground floodlight. The CLS Cas 3 floodlight is a compact but yet powerful inground floodlight for numerous applications. the unit can be used for lighting up all sorts of facades, objects and landscape lighting projects. Included items The CLS Cas 3 is shipped in one package containing the following items: • 1 x CLS Cas 3 inground floodlight • 1 x manual Optional accessories • CLS mold set, straight 8-26mm (item nr. 871992) • CLS Cas 3 sleeve (item nr. 8721553) • CLS Cas 3 frosted frontglass (item nr. 8721556) Note: It is important to read this manual before you install this product. SAFETY INFORMATION Warning! This product is for professional use only, not for domestic use. Read this manual before powering up or installing the CLS Cas 3. Follow the instructions listed below and observe all warnings in this manual. Protection from electric shock • Disconnect the power supply from AC power before installing, dismounting or maintaining the unit. • Make sure all connectors are connected properly. • Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection. • Refer all service to a qualified technician. Available CLS Cas 3 floodlights • CLS Cas 3, 3 x Luxeon III royal blue, flood (45º) (item nr. 8721560)* • CLS Cas 3, 3 x Luxeon III cold white, flood (45º) (item nr. 8721563)* • CLS Cas 3, 3 x Luxeon III amber, flood (45º) (item nr. 8721565)* • CLS Cas 3, 3 x Luxeon III green, flood (45º) (item nr. 8721567)* • CLS Cas 3, 3 x Luxeon III red, flood (45º) (item nr. 8721569)* • CLS Cas 3, 3 x Luxeon K2 extra warm white, 3150K (WW3), flood (45º) (item nr. 8721571)* *Available in Spot (15º) version, MOQ is 50 pcs

Upload: others

Post on 28-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • CLS Manuals

    CLS Atmosphere LED-panelCLS Manuals

    CLS Cas 3 Luxeon III / K2

    www.cls-led.com

    version 2.0 June 2009

    www.cls-led.com- 1 - - 2 -

    CLS Cas 3 Luxeon III / K2

    INTRODUCTIONThank you for choosing the CLS Cas 3 inground floodlight. The CLS Cas 3 floodlight is a compact but yet powerful inground floodlight for numerous applications. the unit can be used for lighting up all sorts offacades, objects and landscape lighting projects.

    Included itemsThe CLS Cas 3 is shipped in one package containing the following items:• 1 x CLS Cas 3 inground floodlight• 1 x manual

    Optional accessories• CLS mold set, straight 8-26mm (item nr. 871992)• CLS Cas 3 sleeve (item nr. 8721553)• CLS Cas 3 frosted frontglass (item nr. 8721556)

    Note: It is important to read this manual before you install this product.

    SAFETY INFORMATIONWarning! This product is for professional use only, not for domestic use.Read this manual before powering up or installing the CLS Cas 3. Follow the instructions listed below and observe all warnings in this manual.

    Protection from electric shock• Disconnect the power supply from AC power before installing, dismounting or maintaining the unit.• Make sure all connectors are connected properly.• Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection.• Refer all service to a qualified technician.

    Available CLS Cas 3 floodlights• CLS Cas 3, 3 x Luxeon III royal blue, flood (45º) (item nr. 8721560)*• CLS Cas 3, 3 x Luxeon III cold white, flood (45º) (item nr. 8721563)*• CLS Cas 3, 3 x Luxeon III amber, flood (45º) (item nr. 8721565)*• CLS Cas 3, 3 x Luxeon III green, flood (45º) (item nr. 8721567)*• CLS Cas 3, 3 x Luxeon III red, flood (45º) (item nr. 8721569)*• CLS Cas 3, 3 x Luxeon K2 extra warm white, 3150K (WW3), flood (45º) (item nr. 8721571)*

    *Available in Spot (15º) version, MOQ is 50 pcs

  • CLS Manuals

    CLS Atmosphere LED-panel

    www.cls-led.com- 3 - - 4 -

    CLS Cas 3 Luxeon III / K2

    INSTALLATIONThis section shows how to install the CLS Cas 3.

    ATTENTION!TO prEvENT dAmAgE TO ThE CLS CAS 3, uSE ThE CLS CAS 3 SLEEvE. mAkE SurE drAINAgE CONdITIONS ArE AdEquATE.ThESE prECAuTIONS muST bE fOLLOwEd, OThErwISE ThE guArANTEE wILL bECOmE INvALId!

    WAR

    NING

    DrainageTo minimize the risk of flooding or water logging, install the fixture in a location which is above the level of the surrounding area, and make sure drainage conditions are adequate. CLS recommends to use gravel for the best drainage conditions. The unit is not designed to withstand high pressure water jets.

    Protection from burns and fire• Do not install the CLS Cas 3 near a heat source.• Do not install the CLS Cas 3 in a corrosive, flammable or explosive area.• Do not modify the CLS Cas 3, or install other than genuine parts.• Do not operate the CLS Cas 3 if the ambient temperature exceeds 40º C.

    Protection from injury due to falls• Verify that all covers and mounting hardware are securely fastened.• Block the access below the work area whenever installing or removing the unit.

    CAbLE INSTALLATION

    Cable slackAllow at least 400 mm of free cable in the installation, so that the fixture is clear for service without disconnecting cables.

    NOTE!For protection from potentially lethal electric shock:

    • The CLS Cas 3 must be grounded.• The AC-power supply must be fitted with a fuse or circuit breaker, ground-fault protection, and a means to isolate the fixture from power during service or when not in use.• Cables and fixtures must be isolated from power, and steps taken to prevent reconnection, before carrying out any work on them.• Do not connect the CLS Cas 3 to an electrical dimmer system: doing so can damage the electronics.

    Connecting to AC-powerConnect the power cable only on the right positions! See diagram for the colours of all electric cables:

    Wire (EU) Function MarkingBrown Live LBlue Neutral NYellow/green Earth

    Obstruction by rootsThe further the fixture is located from vegetation such as trees, hedges or bushes, the less chance there is that the roots will obstruct the fixture or even cause damage to its cables. If the fixture is located close to vegetation, consult a landscape architect about the solutions for the root obstruction.

  • CLS Manuals

    CLS Atmosphere LED-panel

    www.cls-led.com- 5 - - 6 -

    CLS Cas 3 Luxeon III / K2

    25 mmø 28,5 mm

    ø 104 mm

    138 mm118,5 mm

    19,5 mm

    ø 70 mm

    ø 150 mm

    MEASUREMENTS

    Cas 3

    Cas 3 sleeve

    Install example

    Disassemble the stainless steel ring from the CLS Cas 3 by loosening the 4 screws.

    Assemble the stainless steel ring back on the Cas 3 unit. The Cas 3 is ready to be installed.

    To install the Cas 3 into the sleeve, tread the wire trough one of the holes on the side. Slide the Cas 3 unit inside and secure it in the screw holes.

    Install the Cas 3 into the ground. Finish the surface around the fixture with gravel. Ensure that the foundation will withstand pressure on the fixture.

  • CLS Manuals

    CLS Atmosphere LED-panel

    www.cls-led.com- 7 - - 8 -

    CLS Cas 3 Luxeon III / K2

    TEChNICAL SPECIFICATIONSLED: 3 x Luxeon® III or K2Available colours: Luxeon III: royal blue, cold white, amber, green, red Luxeon K2: extra warm white, 3150K (WW3)Lenses: Spot (15°) or Flood (45°)Power supply: 110 ~ 240 VACPower consumption: max. 9 VAWeight: 1,5 Kg IP value: IP65Cable length: 3 metersMeasurements: ø Top: 142 mm - ø inground: 98 mmAmbient temperature: -20º till +40º CMax. pressure: 15 kg/cm2

    Multiple connectionPossiblities on a fixture

    Installation depthIn centimeters

    SwivelFixture is horizontally rotatable, indicated in degrees

    SwivelFixture is vertically rotatable,indicated in degrees

    Mounting holeIn centimeters

    Application areaIndoor or outdoor

    Application areaFloor, wall or ceiling

    Protection classOne, two or three

    350º

    350°

    Cable lengthMaximum cable attachedon the fixture in centimeters

    LifespanOf the light source in hours

    DriverInclusive or exclusive

    PressureMaximum pressure on the fixture per kg/cm2

    WeightIn gram/kilogram

    CurveMinimal bending curvein centimeters

    Driver

    Incl.

    10.000 h

    Driver

    Excl.

    200 cm

    6 cm

    LED pitchPitch between the LEDs in millimeters

    20 mm

    15kg/cm2

    4x4 cm4 cm

    4 cm4 cm

    4 cm

    List of symbols

    2007 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. No part of this manual may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions to be found on the back of your CLS-LED BV invoice or on our website www.cls-led.com/Conditions.pdf