Introducing 7820A GC System
Reliability, Simplicity & Affordability!
7820A GC System Key Features
Page 2
New 7693A ALS with 16 vial capacity
Simplified display and keys
Detectors include
ECD, NPD, TCD, and FID.Full EPC from inlets to
detectors
New generation architecture for proven reliability/quality
March 2009
Ezchrom Elite Compact Software ControlLarge oven for
dual column operation
Who are the Target Customers?
Typical 7820A customers can be found across all industries:
– Budget limited
– Routine testing typically with local (non‐international) methods (QA/QC)
– Not a high throughput lab
– Generally small to medium size organizations
– Government testing labs at local district level
– Need basic GC functionality with just “good enough” performance
Page 3
Introducing 7820A GC SystemAgilent Restricted
February 2009
7820A GC System Overall Features
Introducing 7820A GC SystemAgilent Restricted
February 2009Page 4
7820AGC system
Control and
data
handling
Service
Inlet
w/EPC
EZChrom Elite Compact
Column and consumables
Purge
Packed
Valve
ECDDetector w/EPC
FID
TCD
LAN
Cap
Split/splitless
Analog output
1 Checkout
Column
Consumables Kits
Installation, Familiarization
Technical
support
NPD
Self‐installa
tion Software Keypad
Flexible configuration, two channels system
7820A Highlighted Features
Full EPC Control from Inlet to Detector
New ALS with 16 Sample Vials
Intuitive and Innovative User Interface
Powerful and Escalable EzChrom Compact Software
Agilent Quality
7820A Consumable Kits with Excellent Value
Page 6
Agilent 7820A GC Highlighted FeatureAll GC gas flows electronically controlled
Introducing 7820A GC SystemAgilent Restricted
February 2009
Older Manual Pneumatic System
Page 7
EPC Benefits
Ease of use No need for bubble meter and stop watch for setting gas flows. For switching between methods, the gas flows are saved with the method. This includes inlets and detectors.
Better Quality Data EPC technology allows better retention time and peak area repeatability from run to run.
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 8
Agilent 7820A GC Highlighted FeatureNew 16‐vial Automatic Liquid Sampler
Benefits
More accurate result over manual injections
Automation; possible to have sample analyzed overnight without adding night shift
Less training for new operators
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 9
Agilent 7820A GC Highlighted FeatureSpecially designed GC user interface
Benefits
7820’s user interface has been simplified, minimizing the chance of operator error.
• Complex keypad has been reduced to 5 buttons.
7820’s display shows instrument’s status in English or Chinese
• Temperature zones, flows, pressures, signals, run times
7820 indicator lights show the instrument’s working status:
• running, error, not ready;
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 10
7820A GC User Interface
Introducing 7820A GC SystemAgilent Restricted
February 2009
• Five‐key Interface
• Software keypad
Page 11
Introducing 7820A GC SystemAgilent Restricted
February 2009
Software Keypad
Same functions as a GC keypad
Displays GC actual and setpoint
Necessary for GC method creation and control when customer uses integrator or 3rd party data processing software.
7820A Ease‐of‐use
• Dedicatedly designed user interface with only five keys which are most used, minimized operation error. Easy to learn, easy to use.
• Technician level customer could use software or software keypad to control instrument, set up methods and conduct daily maintenance. Operating level customer could reply on the easy‐to‐use simplified instrument user interface to conduction daily operation.
Power and Scalable Instrument Control and Data Handling System
EZChrom Elite Compact Software
A low cost subset of EZChrom Elite Workstation
Optional with 7820 GC Hardware
Localized for Chinese and Japanese Markets
Supports 2‐ 7820A GC systems or a 7820A GC and a 1120 HPLC
Compliance functionality available as an option
Upgradable to EZChrom Elite Workstation
Page 14Page 14
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 15
Introducing 7820A GC SystemAgilent Restricted
February 2009
EZChrom Elite Compact Software Configuration
Controls up to Two instruments per workstation
(1120 LC or 7820 GC)
Page 16 February 2009Page 16
EZChrom Elite Compact Scalability
Scalable member of the Lab Informatics Portfolio
Upgradable as your lab grows. Your data methods and reports are all readable across all members of the product line
Same user interface – no re‐training needed
Introducing 7820A GC SystemAgilent Restricted
Page 17
Introducing 7820A GC SystemAgilent Restricted
February 2009
EZChrom Elite Compact Software
View Instrument Status, current data and Run Queue on a single screen
Auto‐increment of sample ID and Autosampler Vial Number
Reports generated automatically
Page 18
Standard Reports in EZChrom Elite Compact
Predefined Reports in one mouse click
Use Pre‐installed reports or add your own
Page 18
Ease of Use
Introducing 7820A GC SystemAgilent Restricted
February 2009
Agilent Quality
Page 20
Quality Programs and Certifications
Typical Agilent GCs go through 3,600 hours of quality testing and 26,000 hours of life testing during development.
These products must pass over 150 quality production inspectionsand 58 rigorous safety tests.
These tests cover electrical, fire mechanical, chemical, fluid pressure, acoustic, and explosive hazards.
Introducing 7820A GC SystemAgilent Restricted
February 2009
Agilent quality – Build in design
7820 GC passed 58 rigorous quality tests that cover electrical, fire, mechanical,
chemical, fluid pressure, and explosive hazards
50g shock testExplosion test
Radiated Emission Package Test
Vibration Test Temperature and Humidity Test
Agilent quality – Build in design
Agilent quality – Control process ensure that 7820 works and keeps working
7820 GC pass over 150 quality production inspections. And they are shipped with a specially designed checkout sample so performancecan be verified after installation
Continuous process improvement and advanced quality tools are used in production, such as Six sigma, Lean.
2009‐6‐25Agilent Restricted
23
Page 24
Agilent –Ensures of Value and Quality
Instruments designed and built for long life
• Fully staffed quality engineers and furnished testing labs at four sites
• International standards and certifications
• Design for reliability, and supportability
There is extensive support
• Number of service engineers and depth of training
• Web resources
• Applications chemists
• Local and internet seminars
• Breadth of services
• 10 year value promise
Factors not reflected in specifications!
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 25
Excellent Value of 7820A Consumables Kits
5 different kits!
Optimized to increase 7820A GC’s performance and to reduce maintenance downtime .
30% discountover list price
Introducing 7820A GC SystemAgilent Restricted
February 2009
Agilent 7820 GC, your easy choice
Full EPC from Inlet to Detector
New ALS with 16 Sample Vials
Intuitive and Innovative User Interface
Powerful and Escalable EzChrom Compact Software
Agilent Quality ensures
7820A Consumable Kits with Excellent Value
7820 ApplicationBy Wang Chunxiao & Liu Wenmin
Application
Page 28
Organochlorine pesticides in drinking water analysis
Aromatic Solvent Purity Analysis
Application HighlightsHPI
Aromatic solvent purity analysis
‐‐ An easy‐to‐use, single‐column method for aromatic solvent purity analysis that meets the requirements of ten separate ASTM methods
‐‐ EPC control and automatic injection ensures excellent repeatability for Retention time & peak area.
‐‐ FID’s wide dynamic range enables a quantitative analysis of samples containing both very high & low concentrations in a single run
Page 29
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 30
Unified of Aromatic Solvent Analysis
1 heptane
2 cyclohexane
3 octane
4 nonane
5 bezene
6 decane
7 toluene
8 undecane
9 ethylbenzene
10 p‐xylene
11 m‐xylene
12 cumene
13 dodecane
14 o‐xylene
15 propybenzene
16 p‐ethyltoluene
17 m‐ethyltoluene
18 t‐butylbenzene
19 s‐butybenzene
20 styene
21 tridecane
22 diethylbenzene
23 n‐butylbenzene
24 a‐methylstyrene
25 phenyacetylene
…… Chromatographic overlay of 11 runs shows outstanding Chromatographic overlay of 11 runs shows outstanding repeatabilityrepeatability
Separation of 25 compounds analyzed by the ten ASTM Separation of 25 compounds analyzed by the ten ASTM aromatics methods listedaromatics methods listed
Sample size: 0.5uL, Split ratio: 100:1Oven temperature program:75 °C (10 min); 3 °C/min to 100 °C, 10°C/min to 145 °C
pA
Min
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 31
Trace Impurities in Benzene Analysis
>99% benzene is still visible without exceeding the >99% benzene is still visible without exceeding the instrumental dynamic range if drawn to full scale instrumental dynamic range if drawn to full scale
Sample size: 0.5uL, Split ratio:30:1 Oven temperature program: 75 °C (10 min); 3 °C/min to 100 °C
…… Quantitative analysis of samples containing both very high and Quantitative analysis of samples containing both very high and very very low concentrations in a single runlow concentrations in a single run
Introducing 7820A GC SystemAgilent Restricted
February 2009
Trace Impurities in Benzene Analysis– RSD%
Cyclohexane Nonane Bezene Toluene 1,4-dioxane Ethylbenzene
Peak Area
Mean 430588.36 861794.27 900519436 590497.3 56348.45 688515.09
%RSD 1.59 1.66 1.66 1.59 1.49 1.61
Retention Time
Mean 3.562 4.504 5.370 7.398 8.006 10.564
%RSD 0.02 0.03 0.02 0.01 0.02 0.01
…… Excellent repeatability for both peak area and RT thanks to EPExcellent repeatability for both peak area and RT thanks to EPC control and C control and automatic injectionautomatic injection
Introducing 7820A GC SystemAgilent Restricted
February 2009
7820A FID Wide Linear Dynamic Range
Page 33
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1E-09 1E-08 1E-07 1E-06 1E-05 0.0001 0.001 0.01 0.1
Mass(g)
Response Factor
喷嘴
空气
H2 + 尾吹
气
Benefit: (high and low concentrations coexisting in the sample)
• No longer needs either external or internal standard method, easy‐to‐use Area Normalization method will help generate the same good quality of data
• No need to change scale, all compound tested in one sample injection
Page 34
Application Highlights Environmental
Organochlorine pesticides in drinking water analysis
‐‐μECD’s provides high sensitivity and selectivity for organochlorine
pesticides analysis.
Meets the rugged related regulation across borders.
‐‐ Using Nitrogen as the carrier gas tremendously saves cost compared with helium
‐‐ ALS and EPC ensure good repeatability and ease of use.
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 35
Organochlorine Pesticides Standard Analysis
Sample size: 1uL, SplitlessOven temperature program: 50 °C (3 min); 30 °C/min to 210 °C (30min)
…… μμECDECD’’s high sensitivity ensures the trace organochlorine pesticides as high sensitivity ensures the trace organochlorine pesticides analysis at nalysis at 0.5 μg/Lwith good S/Nwith good S/N
1
2
3
4
5
6
7 8
Minutes
12 14 16 18 20 22 24 26 28 30 Min
Hz
125
130
135
140
145
150
155
160
1
2
3
4
5
6
7 8
1. α‐BHC
2. Lindane
3. β‐BHC
4. δ‐BHC
5. p,p’‐DDE
6. o,p’‐DDT
7. p,p’‐DDD
8. p,p’‐DDT
0.5 0.5 μμg/L (0.5 ppb) pesticides standardg/L (0.5 ppb) pesticides standard
Introducing 7820A GC SystemAgilent Restricted
February 2009
Page 36
Organochlorine Pesticides in Drinking Water Analysis
…… μμECDECD’’s high sensitivity and selectivity ensures the trace organochlors high sensitivity and selectivity ensures the trace organochlorine ine pesticides in real sample.pesticides in real sample.
10 ppb pesticides spiked drinking water10 ppb pesticides spiked drinking water
1. α‐BHC
2. Lindane
3. β‐BHC
4. δ‐BHC
5. p,p’‐DDE
6. o,p’‐DDT
7. p,p’‐DDD
8. p,p’‐DDT
5
2
1
3
4
6 7 8
Min0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 3212 14 16 18 20 22 24 26 28 30 32
Hz
200
400
600
800
1000
1200
1400
1600
1800
2000
Sample size: 1uL, SplitlessOven temperature program: 50 °C (3 min); 30 °C/min to 210 °C (30min)
Introducing 7820A GC SystemAgilent Restricted
February 2009
Organochlorine Pesticides Aanalysis – linearity
Peak No.
Com-pounds
Linear range(ppb)
Corresponding Coefficient ( R2)
1 α-BHC 0.5-500 0.99982 β-BHC 0.5-500 0.99983 lindane 0.5-500 14 δ-BHC 0.5-500 0.99965 p,p’-DDE 1-500 0.99986 o,p’-DDT 1-500 0.99987 p,p’-DDD 0.5-500 0.99998 p,p-DDT 0.5-500 0.9993
……Unique turbulent mixing and electrical design offer wide linear Unique turbulent mixing and electrical design offer wide linear response range for response range for μμECD ECD
Introducing 7820A GC SystemAgilent Restricted
February 2009
Summary
Reliable, ease of use but cost‐saving solution is 7820A GC customer’s need
Excellent reliability, high sensitivity, wide dynamic range and cost‐saving solution is demonstrated in two application examples
HPI down‐stream, food safety, and environmental are 7820A GC target industries
7820 is the easy choice for your routine analysis