international waterstops for concretespec-kw.com/upload/international_waterstop_brochure_684.pdf ·...
TRANSCRIPT
Typical Structures Requiring Waterstops Include:Water and waste water treatment facilitiesPrimary and secondary containment structuresTunnels and culvertsDams, locks, canals, water reservoirs and aqueductsPipe penetrationsSwimming poolsStorage tanksRetaining wallsFoundationsSlabs on grade
3400 Tree Court Industrial Boulevard, St. Louis, Missouri 63122Phone: 800. 325-9504 or 636. 225-9400Fax: 800. 551-5145 or 636. 225-2049www.Greenstreak.com
INTERNATIONALWATERSTOPS FOR CONCRETE
Concrete structures are only as watertight as the waterstops thatjoin them. Greenstreak waterstops stop leaks before they start...in the joints of concrete structures. Since 1950, Greenstreak has served the general and architecturalconcrete construction industry. Innovation, engineering and quality craftsmanship are combined to produce products of choicefor the industry’s owners, designers and contractors. Greenstreak maintains its position of industry leadership byresponding to the unique needs of our customers. Greenstreak’sdedicated technical and customer service sta�s are active participants in the concrete industry to take advantage of thelatest technological advances, communicate with our marketand analyze trends. Centrally located, Greenstreak products are readily availablethrough a dedicated network of Concrete Forming andAccessory Distributors both nationally and internationally.
Flexible solutions. Concrete performance.
Hydroelectric and FloodControl Projects
Water and Waste Water Treatment Plants
Tel.: +965 1820044 - Fax: +965 24582548www.spec-kw.com - [email protected]
WATERSTOP BASIC USE
Embedded in concrete, across and/or alongthe joint, waterstops form a watertightdiaphragm that prevents the passage offluid through the joint.
SUGGESTED WATERSTOPDESIGN CHECKLIST
u Determine structure typeu Verify chemical containment
requirements (if any)u Verify hydrostatic head pressure
requirementsu Determine joint type and joint
movement requirementsu Verify joinery details of dissimilar or
non-symmetrical waterstop profiles(consider using one profile throughoutto simplify intersections)
u Specify ribbed profile for best watersealing performance
u Specify type and size (by product number, if possible)
u Specify factory fabrications of intersec-tions and heat welded field butt joints
u Specify method for securing waterstopin position (hog rings, grommets, etc.)
PVC WATERSTOP
u The industry standardu Broadest design selectionu Formulated and compounded by
Greenstreaku Manufactured by Greenstreak from
only prime resins and all virgin raw materials
u Great inherent elasticityu Resistant to many waterborne chemicalsu Heat weldableu Will not discolor concrete or produce
electrolytic actionu Suitable for above or below grade
applications
GREENSTREAK PVC Waterstop isavailable in two grades:
—Specification Grade (-40°F/-40°C)
This is the most utilized grade for standardconstruction projects. PVC SpecificationGrade, the industry standard, is maintainedin stock.
Independent laboratory tests are availablefor the following applicable standards:
u Corps of Engineers CRD-C572-74u Bureau of Reclamation C902
—Arctic Grade (-58°F/-50°C)
PVC Waterstop is specially formulated toretain its physical properties and perfor-mance in excessively cold environments.
Requirements available on order to meet:
u Ontario Hydro Standard M-264-81u Canadian General Standards Board
41-GP-35M Type II
SBR AND NEOPRENE RUBBER WATERSTOPS
Greenstreak offers SBR and Neoprene waterstops for applications requiring thephysical properties of rubber.
C A L L G R E E N S T R E A K ’ S T E C H N I C A L S E R V I C E D E PA R T M E N T F O R A S S I S TA N C E W I T H
2
Greenstreak Rubber WaterstopPhysical Properties
ASTM Styrene HighProperty Test Butadiene Tensile
Method (SBR) Neoprene*Tensile Strength
(PSI min) D 412 2,500 2,500
Tensile Strength @ 300% Modulus D 412 1,150 1,150(PSI min)
Ultimate Elongation, D412 450 450(% min)
Durometer, Shore A (+/- 5) D2240 65 65
Water Absorption, 7 Days CRD-C575 5 15at 70°C % Weight Change (% max)
Compression Set, D395 30 3022 hr. @ 70°C % of Original Deflection (max) (Method B)
Accelerated Aging, D57296 hrs. @ 70°C
% of Tensile Strength before 80 80aging (min)
% of Elongation 80 80before aging (min)
Ozone Resistance, 7 Days at 50PPHM D1149 No No@ 38°C, 20% Elong. Cracks Cracks
*Provides maximum resistance to ozone, sewage, oil and solvents
British Standards Test ResultsProperty Test Method Typical Value
Ultimate Tensile BS2782 Strength Method 320A > 15.0 N/mm2
Ultimate BS2782Elongation Method 320A > 325%
BS2782 Elastic Modulus Method 320A > 8.0 N/mm2
BS2782 Density Method 620A 1.38 +/- 5%
Hardness BS2782(Shore A) Method 365B 79 +/- 3
BS2782 Water Absortion Method 430A > 0.1%
Greenstreak PVC Waterstop Physical Properties
PROPERTY TEST TypicalMethod VALUE
Tensile strength ASTM D-638 2000 PSI Min.Ultimate Elongation ASTM D-638 300% Min.Specific gravity ASTM D-792 1.39Stiffness in flexure ASTM D-747 600 PSI Min.Hardness Shore A15 ASTM D-2240 80±3Low temperaturebrittleness @-35°F ASTM D-746 PassWater absorption ASTM D-570 .15% Max.Tensile strength AfterAccelerated extraction CRD-C-572 1850 PSI Min.Elongation AfterAccelerated extraction CRD-C-572 300% Min.Alkali Resistance• weight change CRD-C-572 .20% Max.• hardness change 2 Pts. MaxTear resistance *D624 395 lb./in.
SWELLSTOP TM WATERSTOP
A flexible butyl rubber and swellable claywaterproofing compound that swellsupon contact with water to form a longlasting compression seal in non-moving
concrete joints.
Swellstoprequires a 2”minimum clearcoverage fromthe face of theconcrete.
3
M AT E R I A L T Y P E A N D D E S I G N S E L E C T I O N
TYPES OF CONCRETE JOINTS
Contraction (Control) JointContraction joints are designed planes of weakness to control thelocation of cracks due to shrinkage of concrete.
Expansion (Isolation) JointExpansion joints separate or isolate abutting concrete structures(walls, slabs, footings columns) protecting them from compressive
stresses that may develop due to thermal expansion, settlement,creep, live load deflections, drying shrinkage or crush. Differentialmovement at these joints can be both lateral and transverse.
Construction JointConstruction joints are determined by interruptions in the place-ment of concrete.
Swellstop
Waterstop ApplicationsGrout ribs stop the loss of fines at splitbulkhead (end shutter)
Eyelets on 30 cm centers each side. Eyelets off-set sideto side for easy wire tie to reinforcing.“Sure Form”
Internal for construction joint Internal for expansion joint
External for construction jointExternal with crack inducerfor contraction joint
External for expansion jointExternal for construction jointwall-to-slab
External for construction jointwall-slab-wall
4
20 4 6 313 ID
40150
BrassEyelet
STYLE 951 STD. WT. 31.44 Kg/20 LM ROLL HEAD PRESS. 224 KPa
20 4 6 3.5
34040200
13 ID BrassEyelet
STYLE 952 STD. WT. 39.45 Kg/20 LM ROLL HEAD PRESS. 373 KPa
55 3
3.574.525
25050
17 ID BrassEyelet
STYLE 953 STD. WT. 42.16 Kg/16 LM ROLL HEAD PRESS. 448 KPa
30 10 18 ID 3
5550250
BrassEyelet
STYLE 954 STD. WT. 63.85 Kg/14 LM ROLL HEAD PRESS. 597 KPa
GSK#043Double Headed Nail
Tear Web
5
55
20 16
203
4.5
150
STYLE 923 STD. WT. 30.22 Kg/20 LM ROLL HEAD PRESS. 224 KPa
GSK#043Double Headed Nail
Tear Web
5 4.5
4040
20
2003
16
20
STYLE 924 STD. WT. 43.18 Kg/20 LM ROLL HEAD PRESS. 373 KPa
GSK#043Double Headed Nail
Tear Web
355
25
25
185550
250
STYLE 925 STD. WT. 43.78 Kg/16 LM ROLL HEAD PRESS. 448 KPa
GSK#043Double Headed Nail
35 5
20
550
1055
65
25
18
250
Tear Web
STYLE 926 STD. WT. 26.91 Kg/8 LM ROLL HEAD PRESS. 448 KPa
GroutRibs 36420
40150
BrassEyelet
STYLE 955 STD. WT. 30.12 Kg/20 LM ROLL HEAD PRESS. 224 KPa
GroutRibs20 4 6 3.5 3
4040200
BrassEyelet
STYLE 956 STD. WT. 39.20 Kg/20 LM ROLL HEAD PRESS. 373 KPa
GroutRibs25 4.5 7 3.5 3
5550250
BrassEyelet
STYLE 957 STD. WT.41.56 Kg/16 LM ROLL HEAD PRESS. 448 KPa
GroutRibs30 10 3
5550250
BrassEyelet
STYLE 958 STD. WT. 61.49 Kg/14 LM ROLL HEAD PRESS. 597 KPa
GSK#043Double Headed Nail
GroutRibs
3
20
16
54.5
55
150
STYLE 927 STD. WT. 26.48 Kg/20 LM ROLL HEAD PRESS. 224 KPa
GSK#043Double Headed Nail
GroutRibs
3
16
204.55
4040
200
STYLE 928 STD. WT. 39.42 Kg/20 LM ROLL HEAD PRESS. 373 KPa
GSK#043Double Headed Nail
GroutRibs 3
18
255
5
5550
250
STYLE 929 STD. WT. 39.87 Kg/16 LM ROLL HEAD PRESS. 448 KPa
GSK#043Double Headed Nail
GroutRibs 35 5
18
25
9550
330
STYLE 930 STD. WT. 48.62 Kg/16 LM ROLL HEAD PRESS. 522 KPa
“SURE-FORM” PVC Waterstops
Internal Style: Brass reinforced eyelets for easy wire tie to reinforcing bars.
FOR EXPANSION JOINTS FOR CONSTRUCTION/CONTRACTION JOINTS
External Style: Easy nail-in-place with special two-headed nail — or — lay on grade.FOR EXPANSION JOINTS
Note: All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.
Not to scale
FOR CONSTRUCTION/CONTRACTION JOINTS
03250/GRD
5
GSK#043Double Headed Nail
35525
3
25
18
125135
50
TearWeb
STYLE 931 STD. WT. 8.11 Kg/3 LM
Tear Web
225
1525
240
7
5050
STYLE 938 STD. WT. 49.72 Kg/18 LM ROLL HEAD PRESS. 299 KPa
STYLE 838 STD. WT. 52.48 Kg/32 LM ROLL HEAD PRESS. 448 KPa
25
10230
20 ID & 35 OD
STYLE 933 STD. WT. 51.19 Kg/12 LM ROLL HEAD PRESS. 448 KPa
20
10 13 ID & 23 OD 2.55
260
BrassEyelet
STYLE 936 STD. WT. 45.77 Kg/18 LM ROLL HEAD PRESS. 373 KPa
9.5
63.5 28.6
19
229
STYLE 700 STD. WT. 33.75 Kg/6 LM ROLL HEAD PRESS. 448 KPa
3.2 9.5 8 ID & 22.2 OD 16
152
STYLE 732 STD. WT. 42.86 Kg/18 LM ROLL HEAD PRESS. 373 KPa
3.2 9.5 12.7 ID & 25.4 OD
229
STYLE 735 STD. WT. 58.34 Kg/16 LM ROLL HEAD PRESS. 597 KPa
6.4 9.5 19 ID & 31.8 OD 3.2
229
STYLE 718 STD. WT. 43.76 Kg/14 LM ROLL HEAD PRESS. 597 KPa
STYLE 609 STD. WT. 9.60 Kg/3 LM Retrofit System
GroutRibs
15 522
50507
240
STYLE 937 STD. WT. 45.92 Kg/18 LM ROLL HEAD PRESS. 299 KPa
GroutRibs
25
10230
STYLE 932 STD. WT. 63.49 Kg/16 LM ROLL HEAD PRESS. 448 KPa
GroutRibs
20
10 5 2.5
250
BrassEyelet
STYLE 934 STD. WT. 47.16 Kg/20 LM ROLL HEAD PRESS. 373 KPa
3.95011348 22.2
432
STYLE 777 STD. WT. 73.67 Kg/18 LM ROLL SlabSpan
4.8 9.5 22.2 ID & 38.1 OD 6.4
229
STYLE 696 STD. WT. 39.44 Kg/10 LM ROLL HEAD PRESS. 523 KPa
22.2 12.7 12.7 ID & 31.8 OD 25.4
305
STYLE 712 STD. WT. 91.26 Kg/14 LM ROLL HEAD PRESS. 672 KPa
HEAD PRESS. 299 KPaSTYLE 703 STD. WT. 34.88 Kg/32 LM ROLL
6.4 12.7 22.2 ID & 38.1 ID 4.7
305
STYLE 713 STD. WT. 56.55 Kg/10 LM ROLL HEAD PRESS. 672 KPa
Additional PVC Waterstops
PVC WATERSTOPS
Note: GREENSTREAK manufactures over 100 waterstop profiles in addition to those illustrated in this catalog. If you do not see a profile for your application, contact us. All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.
Available as a system:• #609W6 Waterstop• #609B1 S.S. Batten Bar
2 per 3 meter length of waterstop
• #609S1 S.S. Anchor Bolt42 pcs. per 3 meter length of waterstop
• Epoxy Gel
Not to scale
203mm8"
6.4mm ID & 12.7mm OD1/4" ID & 1/2" OD
5mm13/64"
1/4" ID & 5/8" OD6.4mm ID & 15.9mm OD
6"152.4mm
3/16"4.7mm
1/8"3.2mm
1/8"3.2mm
PVC WATERSTOPS
3.2 4.7
152.43.2
6.4 ID & 15.9 OD
5 6.4 ID & 12.7 OD
203
6
RUBBER SHAPES
3/4"19mm
3/8" 9.5mm
6"152.4mm
7
3/4"19mm
3/8" 9.5mm
6"152.4mm
7
3/4"19mm3/8"
9.5mm
9"228.6mm
3/4"19mm3/8"
9.5mm
9"228.6mm
6"152.4mm
3/4" ID & 1-1/8" OD19mm ID & 28.6 mm OD
1/4"6.3mm
5/8"15.9mm
6"152.4mm
3/4" ID & 1-1/8" OD19mm ID & 28.6 mm OD
1/4"6.3mm
5/8"15.9mm
3/8"9.5mm
1"25.4mm
9"228.6mm
3/4" ID &1-1/2" OD19mm ID & 38.1 OD
7
3/8"9.5mm
1"25.4mm
9"228.6mm
3/4" ID &1-1/2" OD19mm ID & 38.1 OD
7
Neoprene Rubber
918 STD. WT. 1.51 lbs/ft 2.25 Kg/m
919 STD. WT. 2.20 lbs/ft 3.27 Kg/m
920 STD. WT. 1.22 lbs/ft 1.82 Kg/m
921 STD. WT. 2.90 lbs/ft 4.32 Kg/m
Styrene Butadiene Rubber (SBR)
902 STD. WT. 1.30 lbs/ft 1.93 Kg/m
903 STD. WT. 1.90 lbs/ft 2.83 Kg/m
904 STD. WT. 1.05 lbs/ft 1.55 Kg/m
906 STD. WT. 2.50 lbs/ft 3.70 Kg/m
6
PVC FABRICATIONS
Flat “T” Flat “L”Flat “X”
Vertical “X”Vertical “T” Vertical “L”
Vertical “X” Vertical “L” UnionVertical “T”
Rubber Unions (Vertical and Flat)
Note: Adhesive available for bonding rubber intersections (unions).
u Easy to use for straight butt joint splicingu Accommodates small and large size waterstopsu Teflon Pad prevents stickingu Lightweight, easy to useu Thermostatically controlledu 110 VAC. (220 VAC. optional)u Peel and stick covers (replaceable)
Field Splicing Irons
Factory Fabricated Waterstop Intersections
PVC waterstop splices, directionalchanges and intersections are criticalcomponents of a quality installation.Specifications requiring factory madefabrications are strongly recommended.Greenstreak can provide homogenousdirectional changes and intersections,leaving only the less difficult straightsplices to be welded in the field.
Splices, directional changes and intersections are achieved with premolded unions, fittings and a rubber adhesive kit.
RUBBER FITTINGS
356
152
356
25
356
102
#297152 mm heating bar
#21425 mm heating bar
#213102 mm heating bar
9.5
152.4
19
199.519
228.6
152.4
15.9 6.3 19 ID & 28.6 OD
152.4
228.6
15.9 6.3 19 ID & 28.6 OD
25.4 25.49.5 9.5
228.6 228.6
19 ID & 38.1 OD 19 ID & 38.1 OD
Note: All dimensions in (mm) and dimensions are nominal and subject to manufacturing tolerances.
9.5
152.419
9.5
3/4"19mm
S
1" 25.4mm
3/4"19mm
S
1" 25.4mm
Swellstop 594 STD. WT. 0.41 lbs/ft 0.61 Kg/m
Lockstop595 STD. WT. 0.48 lbs/ft 0.71 Kg/m
19
19
25.4
25.4
7
SHEET DRAIN OVERLAP
EDGE TERMINA TION
SLOPE DRAIN AWA YFROM STRUCTURE
FOR VERTICAL INST ALLATION ON CONCRETE OR MASONR Y
SHEET DRAIN, .42 in. (10.67mm) thick with 1 in.(25.4 mm), center-to-center peg spacing is designedfor vertical applications with high flow and moderatecompressive strength requirements.
SHEET DRAIN HS, .25 in. (6.35mm) thick with 1/2
in. (12.7mm), center-to-center peg spacing designedfor vertical applications with moderate flow andexceptional compressive strength requirements.
Sheet Drains
Basic Use: GREENSTREAK® DrainageSystems are lightweight, one sided planardrains. Geocomposite Sheet Drain enhanceswaterproofing systems by reducing hydro-static head pressure on subgrade or retain-ing wall structures. Geocomposite DeckDrain provides horizontal planar drainagefor storm water control under pavers.
Advantagesu Reduces hydrostatic pressure and loadsu Reduces deadload on horizontal decks
by replacing aggregateu Eliminates drainage aggregate stockpiles
on tight job sitesu Minimizes freeze-thaw damageu Lightweight and easy to installu More economical than aggregateu Enhances waterproofing systemsu Protection board for membrane
waterproofingu Easy to ship, transport and store
Deck Drain
DECK DRAIN, .43 in. (10.92mm) thick with 1 in.(25.4mm), center-to-center peg spacing, is designedfor horizontal applications with exceptional flow andhigh compressive strength requirements. DECK DRAINis a sturdy product that withstands rough handlingand abrasion due to thermal expansion and contrac-tion of deck materials. DECK DRAIN may also be usedfor vertical applications where soil conditions dictate amore open filter fabric.
Form Release 7000
Form Release 7000 is specially formulated toprevent concrete from bonding to aluminum,steel, plywood and plastic forms and form liners. Form Release 7000 should be usedwith all reusable Greenstreak Form Liners.
Advantages
u Will not stain gray or white concreteu Will not impair bonding ability of paints,
epoxies or other coatings
u Rust inhibitors help prevent stains inconcrete and deterioration of forms
u Minimizes form clean-upu Lengthens life of wooden formsCoverageu 300-400% higher than most
premium releasesu Steel, aluminum, plastic, high density
plywood…3000-4000 ft2/ gal.
u Plywood, concrete…1000-1500 ft2/ gal.u Rough sawn, dimensional, striated
plywood…800-1000 ft2/ gal.
Technical
u Consists of fatty wood derivatives in alight amber clear hydrocarbon carrier
u Contains no lubricating oil, diesel oil,conventional form oil or kerosene
u Red label not required
3400 Tree Court Industrial Blvd., St. Louis, Missouri 63122 U.S.A.Phone: 800. 325-9504 or 636. 225-9400 • Fax: 800. 551-5145 or 636. 225-9854www.Greenstreak.com email: [email protected]
Printed in U.S.A.08/08
LIMITED WARRANTY: GREENSTREAK® warrants to the Buyer that this product will be free from defects and will perform as represented in writing subject to the two (2) following conditions:
First, the application of the product and the concrete construction practices used in the application are in accordance with GREENSTREAK®’s recommendations; and,
Second, the Buyer has selected the proper product for the specific application required. GREENSTREAK® disclaims any responsibility for the selection of a particular waterstop product. Product selection is the sole responsibility and decision of the Buyer. The suitability of any material for a specific application requiring fluid resistance is best determined by specific testing for the application. GREENSTREAK® urges the Buyer to conductits own site application testing.
Any information supplied by GREENSTREAK® with respect to its products is believed to be correct. GREENSTREAK® makes no representations or warranties, express or implied, as to the accuracy or completeness of suchinformation or the use of such information for a particular purpose. GREENSTREAK® has not performed any tests. Any test data has been prepared by independent commercial laboratories.
Because GREENSTREAK® has no control over either the application or the selection of its products, GREENSTREAK®’s Limited Warranty is as follows:
The exclusive remedies of the Buyer and the limit of the liability of GREENSTREAK® from any and all losses or damages resulting from the use of this product (including claims based oncontract, negligence, strict liability, or otherwise) shall be either the full refund of the purchase price to Buyer of this product or the replacement of the quantity of product purchased by theBuyer – at the election of GREENSTREAK®. In no event shall GREENSTREAK® be liable for any incidental or consequential damages. The Buyer and all users of this product are deemed tohave accepted the terms of this Limited Warranty which may not be varied in any way by any verbal or written agreement.
Architectural Concrete
FORM LINERSForm Follows Function Greenstreak® Architectural Concrete Form Linersmake it easy to pour interesting detail into a structure…without pouring in a lot of money.
Greenstreak Form liners are available in severalgrades and are ideal for texturing tilt-up, cast-in-place and precast concrete.
Greenstreak Form Liners are attached to the forming system or casting bed prior to concreteplacement. After normal placement and curingtime, the form work and liner are stripped, leavingan architectural finish in the concrete.
Just a few Greenstreak patterns are shownin this catalog. Call Greenstreak for addi-tional pattern details or if you would likeus to create a custom pattern or design.
# 360
# 337
# 373
# 351
# 302