intermec solutions for hazardous environments: ck32is

27
Intermec Solutions for Hazardous Environments: CK32IS

Upload: amber-hawthorne

Post on 22-Dec-2015

218 views

Category:

Documents


0 download

TRANSCRIPT

Intermec Solutions for Hazardous Environments: CK32IS

Slide 2

UL(Underwriters Laboratory)

ATEX(European Atmospheres Explosibles Directives)

IEC(International Electrotechnical Commission)

Global Considerations Global Certification requirements

U.S.CanadaMexico

European Union

NorwaySwitzerlandTurkey

AustraliaSingapore MalaysiaPhilippinesIndonesiaSaudi Arabia

Austria BelgiumBulgaria Cyprus Czech Republic Denmark EstoniaFinland FranceGermany Greece Hungary Ireland Italy

Latvia Lithuania Luxembourg Malta Netherlands Poland PortugalRomaniaSlovakia Slovenia Spain Sweden United Kingdom of Great Britain and Northern Ireland

Slide 3

Hazardous Environment Certifications UL, ATEX, IEC

Localized Languages English, Spanish, French, German, Italian, Simplified Chinese, Traditional Chinese,Korean, Thai (character set only)

RoHS Compliance Restriction of the Use of Certain Hazardous Substance in Electrical and ElectronicEquipment

WEEE Compliance Waste Electrical and Electronic Equipment

RF Certifications Support & Service

Certified repairs at all service centers worldwide

Global Reach

Slide 4

UL(Underwriters Laboratory)

ATEX(European Atmospheres Explosibles Directives)

IEC(International Electrotechnical Commission)

Hazardous Certifications

Gases, Liquids, VaporsClass I Division 1 Group A,B,C,D (T4)Class 1 Zone 0 Group IIC (T4)

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Dusts & FibersClass II Division 1 Groups E, F and G

Dusts & FibersZone 20 Group II* T250°C

Dusts & FibersZone 20 Group II* T250°C

Underground MiningGroup I M1

Underground MiningGroup I M1

Class III Division 1

* Except conductive dust

Slide 5

UL(Underwriters Laboratory)

ATEX(European Atmospheres Explosibles Directives)

IEC(International Electrotechnical Commission)

Hazardous Certifications

* Except conductive dust

From concept, design specifications dedicated to meeting customer’s most stringent requirements for flammable gases, vapors, liquids, dusts or fibers.

Gases, Liquids, VaporsClass I Division 1 Group A,B,C,D (T4)Class 1 Zone 0 Group IIC (T4)

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Dusts & FibersClass II Division 1 Groups E, F and G

Dusts & FibersZone 20 Group II* T250°C

Dusts & FibersZone 20 Group II* T250°C

Underground MiningGroup I M1

Underground MiningGroup I M1

Class III Division 1

Slide 6

High Level Device Requirements

Chemical, Oil & Gas, and Pharmaceutical customers told us their “ideal” requirements: One Device - Globally

One Manufacturer - Globally

Long Product Life Cycle

Industry Commitment - Globally

Global Technical Support & Service

Slide 7

Detailed Device Requirements – Typical Customer Device: Windows mobile PDA

Hazardous Ratings: 60% - UL Class 1 Div 2 for North America 5% - UL Class 1 Div 1 for North America 20% - ATEX Zone 2 for Europe 5% - ATEX Zone 1 for Europe 10% - IEC, Rest of World (RoW)

Memory: 128 MB of RAM / 512 MB of Flash Storage

Communications: 802.11b/g Cisco CCX V3 radio support Bluetooth – Used to talk to peripherals (RFID, Vibration, Temperature probes)

Keyboard/Ergonomics: Big, easy to use Arrows & Numeric Keys (for use in gloved environments) User installable Trigger Handle

Support: 8 Hours of Battery Life No loss of data/application after cold boot Global Support Lock Down Application

Slide 8

Detailed Device Requirements – What are yours?

Device? Hazardous Ratings? Memory? Communications? Keyboard/Ergonomics? Support?

Slide 9

Enterprise Asset Management Solutions Example: Plant Maintenance & Repair Trend

Good maintenance and support practices are an integral component of optimized production processes and lean manufacturing.

Key Issues Manufacturers are focused on improving the efficiency of production. As production capacity rises above 80% utilization, efficiency and productivity in plant maintenance and repair is mandatory. Return on Assets (ROA) is becoming the primary driver of equipment investment.

Solutions In-premise and extra-premise predictive maintenance. Break-Fix operations. Dispatching for optimized production. Operator directed response (ODR).

Slide 10

Intermec Hazardous Environment Solutions

751 Class I Div 2 751 ATEX Zone 2 730 Class I Div 1

CK31 Class I Div 2 CK61 Class I Div 2 CK32IS

Slide 11

Intermec Hazardous Environment Solutions

751 Class 1 Div 2 751 ATEX Zone 2 730 Class 1 Div 1

CK31 Class 1 Div 2 CK61 Class1 Div 2 CK32IS

Mobile ComputersFixed Mount Computers

RFID Scanners Printers

Intermec Solutions Family

CK32 Intrinsically Safe Mobile Computer

Slide 13

CK32IS Features

Intermec Linear Imager

42 or 56 Keypad options (Standard, 3270/5250, VT/ANSI)

128 MB RAM 512 MB Persistent Storage

QVGA Color Display w/ Touchscreen

Intel XScale PXA270 Processor

802.11b/g WLAN w/ CCX 3, USB Bluetooth & Ethernet

Windows Mobile 5.0 Premium & Phone Edition & MSFP

Integrated Speaker/microphone

Slide 14

CK32IS Usability

User installable trigger handle

Batteries removable in hazardous environments

Keypad options support gloved use

Slide 15

CK32IS Accessories

* Associated Apparatus Certified – Guarantees that any outside equipment cannot damage the unit. Not for use in Hazardous environments.

Communication Adapter* USB Client and Ethernet Battery Eliminator

Battery Pack Option Quad Battery Charger* Trigger Handle

User Installable Carrying Strap

Leather Hand Strap Screen Protector Kit Tethered Stylus Kit

Slide 16

CK32IS Durability

Electrostatic Dissipation Internal Antennas Hard Plastic Key tops Polycarbonate Enclosure Internal Magnesium Frame Internal Shock Mounting Encapsulated Circuit Boards

Designed from inception for exceptional durability 5 foot drop specification IP67 sealed Operating temperature: -20°C to +50°C Robust construction:

Slide 17

Hardware Durability

Internal Magnesium Frame Thicker than comparable frame in standard product Lightweight but strong Internal skeleton

Slide 18

Hardware Durability

Magnesium frame Reduces flexing, risk of damage Maintains relative alignment and spacing Protects LCD display glass

Slide 19

Hardware Durability

Encapsulated Circuit Boards High temperature silicon for thermal insulation Second line of protection against gas & dust Protects components from shock, vibration, corrosion

Slide 20

Hardware Durability

Internal Shock Mounting Isolates electronic modules Display

Slide 21

Hardware Durability

Hard Plastic Key Caps Laser engraved Silicon Keypad

Touch ScreenTouch Screen Protector

Slide 22

Hardware Durability

Polycarbonate Enclosure Extra thick, high quality, reinforced Conductive

IP67-rated sealModular construction

Slide 23

Worldwide Service & SupportMedallion service contracts

Tel and web based post sales support

More than 70 service & support facilities Local languages, time zones

Intermec Repair LocationsIntermec Global Service Partners

Slide 24

UL(Underwriters Laboratory)

ATEX(European Atmospheres Explosibles Directives)

IEC(International Electrotechnical Commission)

CK32IS Hazardous Certifications Certified Intrinsically Safe by ALL 3 global agencies, for gases, vapors, liquids,

dusts, fibers and underground mining. Today’s safety requirements. And tomorrow’s.

* Except conductive dust

Gases, Liquids, VaporsClass I Division 1 Group A,B,C,D (T4)Class 1 Zone 0 Group IIC (T4)

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Gases, Liquids, VaporsZone 0 (T4) Group IIC

Dusts & FibersClass II Division 1 Groups E, F and G

Dusts & FibersZone 20 Group II* T250°C

Dusts & FibersZone 20 Group II* T250°C

Underground MiningGroup I M1

Underground MiningGroup I M1

Class III Division 1

Slide 25

Designed to Deliver Highest Level of Safety Full International Safety Certifications

in One Computer

Meets or Exceeds Latest Safety Standards: Zone 0

Exceptionally Rugged: 5’ drop, IP67

Worldwide Service & Support

Slide 26

Next Steps Compliance:

Define your safety certification requirements

Configuration: Determine detailed device requirements

Service & Support: Determine global needs

Slide 27

Thank you!

ADC Nordic - Distributor in the Nordic countries

Phone +46 40-680 02 80