interior renovation · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp....

13
APPROXIMATE DIAMETER ACCESSIBLE AMERICAN CONCRETE INSTITUTE ACOUSTICAL CEILING TILE ADMINISTRATION AMERICANS WITH DISABILITIES ACT ADJACENT AIR CONDITIONING ABOVE FINISH FLOOR ALTERNATE ALUMINUM ARCHITECT BUILDING BOARD BLOCKING BEAM BOTTOM OF BOTTOM OF BEAM BETWEEN CONTROL JOINT CENTER LINE, CLEAR CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CORRIDOR CARPET CERAMIC TILE CENTERED DRYER DISPLAY BOARD DOUBLE DICTATION DEGREES DETAIL DETENTION HOLLOW METAL DIAMETER DIMENSION DOWN DOOR DOWN SPOUT DRAWING(S) DISHWASHER EACH ELECTRIC DRINKING FOUNTAIN EXTERIOR INSULATION & FINISH SYSTEM EXPANSION JOINT ELECTRICAL ELEVATION EQUAL EXISTING TO REMAIN EXISTING EXPANSION EXTERIOR EACH WAY ± Ø ACC ACI ACT AD, ADMIN ADA ADJ AC AFF ALT AL, ALUM ARCH BLDG BD, BRD. BLKG BM B.O. B.O.B. BTWN C.J. CL CLG CLR CMU COL CONC CONT CORR CPT CT CTRD D DB DBL DCTN DEG DTL DHM DIA DIM DN DR DS DWG DW EA EDF EIFS EJ ELEC ELEV EQ ETR EXIST EXP EXT EW FD FE FEC FF, FIN. FLR. FG FHC FIN FLR FO FR FRTW FT FV GA GALV GBF GBP GC GUT GYP. GWB H/C HDW HGT, HT HM HORIZ HR HWY IBC IN INSUL JST JT LAV MB MAX MECH MFR MIN M.O. MPE MTD MTL NFPA NLB NO N.T.S. O.C. OCC OFCI OFOI OH, OPP HD PLT PLAM PLUMB PLYWD PSI PT, PTD PVC PREP PR, PRES FLOOR DRAIN FIRE EXTINGUISHER (WALL MOUNTED) FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH GRADE FIRE HOSE CABINET FINISH FLOOR FACE OF FIRE RATED FIRE RATED TREATED WOOD FEET, FOOT FIELD VERIFY GAUGE GALVANIZED GYPSUM BOARD FURRING GYPSUM BOARD PARTITION GENERAL CONTRACTOR GUTTER GYPSUM GYPSUM WALL BOARD HANDICAP HARDWARE HEIGHT HOLLOW METAL HORIZONTAL HOUR HIGHWAY INTERNATIONAL BUILDING CODE 2003 EDITION INCH(ES) INSULATION JOIST JOINT LAVATORY MARKER BOARD MAXIMUM MECHANICAL MANUFACTURER('S) MINIMUM MASONRY OPENING MECHANICAL, PLUMBING, ELECTRICAL MOUNTED METAL NATIONAL FIRE PROTECTION ASSOCIATION NON LOAD BEARING NUMBER NOT TO SCALE ON CENTER OCCUPANT OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OPPOSITE HAND PLATE PLASTIC LAMINATE PLUMBING PLYWOOD POUNDS PER SQUARE INCH PAINTED POLYVINYL CHLORIDE PREPARE PRESSURE R, RAD RD R&S REC REF RE: , REFER REINF REQ'D RJ RM R.O. SCHED, SCHD SECT SEG SF SHTNG SHT SIM SPEC(S) SPEC'D STC STD STF STL STOR STRUC, STRUCT SUSP SQ SYS TAS TB TBTP T.C. T.C.C. TEL TLT T.O. T.O.F. T.O.P. T.O.S. T.O.W. TP TS TST TYP. TR UL U.N.O. VCT VERT VER VOS W W/ WC WD WDW WH WR WWF RADIUS ROOF DRAIN ROD AND SHELF RECOMMENDATION(S) REFRIGERATOR REFERENCE REINFORCING REQUIRED RUSTICATION JOINT ROOM ROUGH OPENING SCHEDULED SECTION SEGREGATION SQUARE FEET SHEATHING SHEET SIMILAR SPECIFICATIONS SPECIFIED SOUND TRANSMISSION CLASS STANDARD STAFF STEEL STORAGE STRUCTURE/ STRUCTURAL SUSPENDED SQUARE SYSTEM TEXAS ACCESSIBILITY STANDARDS TACK BOARD TAPE BED TEXTURE & PAINT TOP OF CURB TOP OF CONCRETE TELEPHONE TOILET TOP OF TOP OF FLATWORK TOP OF PARAPET TOP OF STEEL TOP OF WALL TOP OF PAVING TUBULAR STEEL TRANSITION STRIP TYPICAL TREATED UNDERWRITERS LABORATORIES UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY VERIFY ON SITE WASHER WITH WATER CLOSET WOOD WINDOW WATER HEATER WATER RESISTANT WELDED WIRE FABRIC ABBREVIATIONS: SHEET NUMBER SECTION NUMBER DETAIL NUMBER SHEET NUMBER NEW SPOT ELEVATION EXISTING HEIGHT EXISTING HEIGHT PROPOSED HEIGHT PROPOSED HEIGHT BENCH MARK GLAZING TYPES TAG A 1 KEYED NOTE TAG - DEMOLITION PLAN ENLARGED PLAN EXISTING AND NEW PARTITION TYPES TAG 1 KEYED NOTE TAG - FLOOR PLAN, REFLECTED CEILING PLAN, AND ELEVATION, SECTION & DETAILS B HOLLOW METAL TAG EXISTING SPOT ELEVATION A TOILET ACCESSORIES TAG WINDOW TAG DOOR TAG ROOM TAG ROOM NAME ROOM NUMBER COLUMN TAG 1 CEILING TAG A NORTH SCHEDULE ID TAG SHEET NUMBER ELEVATION ELEVATION NUMBER 101 ROOM A.0 E-1 EQUIPMENT TAG 100.00 100.00 101 0 A-000 0 A-000 0 A-000 0 A-000 X-XXX TITLE X SCALE: 1/8" = 1'-0" NEW PARTITION TYPES TAG A1 A B E1 A1 T-1 SYMBOLS PROJECT LOCATION: MESA BUILDING VACINITY MAP SHEET: &RS\ULJKW 2015 Vandergriff Group Architects and Planners, A.I.A. 312 N. BIG SPRING SUITE 100 (432)687-0781 MIDLAND, TEXAS VANDERGRIFF GROUP A R C H I T E C T S P C REVISION NO. DATE: DESCRIPTION: Project: 03615 4901 E UNIVERSITY BLVD ODESSA, TEXAS 79762 G-001 DATE: 8/23/2016 COVER SHEET UTPB MESA BUILDING DEMARC ROOM INTERIOR RENOVATION 4901 E UNIVERSITY BLVD ODESSA, TEXAS 79762 DRAWING INDEX GENEREAL G-001 COVER SHEET ARCHITECTURAL A-201 DEMOLITION FLOOR PLAN - GROUND FLOOR A-202 DEMOLITION FLOOR PLAN - MEZZANINE LEVEL A-301 FLOOR PLAN, REFLECTED CEILING PLAN - GROUND FLOOR A-321 DETAILS MECHANICAL M-201 DEMOLITION FLOOR PLANS - MECHANICAL M-301 FLOOR PLAN - MECHANICAL M-401 FLOOR PLAN - MECHANICAL PIPING PLUMBING P-201 FLOOR PLANS - PLUMBING ELECTRICAL E-101 ELECTRICAL LEGEND AND DETAILS E-201 DEMOLITION FLOOR PLANS - ELECTRICAL E-301 FLOOR PLAN - LIGHTING E-401 FLOOR PLAN - POWER & SPECIAL SYSTEMS MEP ENGINEER: MECHANICAL & ELECTRICAL CONSULTING ENGINEERS AGNEW ASSOCIATES, INC. (806) 799-0753 FAX: LUBBOCK, TEXAS AUSTIN, TEXAS PHONE: (806) 799-2014 (512) 310-0750 FAX: (512) 828-0753 PHONE: WWW.AGNEWASSOCIATES.COM ARCHITECT: UNIVERSITY of TEXAS of the PERMIAN BASIN UTPB MESA BUILDING DEMARC ROOM INTERIOR RENOVATION NOTE TO CONTRACTOR AND SUB-CONTRACTOR: EVERY EFFORT HAS BEEN MADE TO MAKE THESE DOCUMENTS CONCISE AND COORDINATED, TO DEFINE WORK IN THE MOST LOGICAL PLACE AND TO ELIMINATE REDUNDANCY. DO NOT PRESUME THAT YOUR SCOPE OF WORK IS SINGULARLY DEFINED. YOUR SCOPE OF WORK IS DEFINED THROUGHOUT THE ENTIRE SET OF DRAWINGS AND SPECIFICATIONS AND IS NOT CONTAINED IN JUST ONE SERIES OF DRAWINGS OR DIVISION OF SPECIFICATIONS. YOU MUST REVIEW THE ENTIRE SET OF CONTRACT DOCUMENTS TO DETERMINE YOUR SCOPE OF WORK. NO ADDITIONAL COST SHALL BE ASSESSED TO THE OWNER FOR NOT UNDERSTANDING SCOPE OF WORK. IF CONFLICT OCCURS, CONTACT ARCHITECT OF RECORD PRIOR TO COMMENCEMENT OF WORK.

Upload: others

Post on 10-Sep-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

APPROXIMATE

DIAMETER

ACCESSIBLE

AMERICAN CONCRETE INSTITUTE

ACOUSTICAL CEILING TILE

ADMINISTRATION

AMERICANS WITH DISABILITIES ACT

ADJACENT

AIR CONDITIONING

ABOVE FINISH FLOOR

ALTERNATE

ALUMINUM

ARCHITECT

BUILDING

BOARD

BLOCKING

BEAM

BOTTOM OF

BOTTOM OF BEAM

BETWEEN

CONTROL JOINT

CENTER LINE, CLEAR

CEILING

CLEAR

CONCRETE MASONRY UNIT

COLUMN

CONCRETE

CONTINUOUS

CORRIDOR

CARPET

CERAMIC TILE

CENTERED

DRYER

DISPLAY BOARD

DOUBLE

DICTATION

DEGREES

DETAIL

DETENTION HOLLOW METAL

DIAMETER

DIMENSION

DOWN

DOOR

DOWN SPOUT

DRAWING(S)

DISHWASHER

EACH

ELECTRIC DRINKING FOUNTAIN

EXTERIOR INSULATION & FINISH SYSTEM

EXPANSION JOINT

ELECTRICAL

ELEVATION

EQUAL

EXISTING TO REMAIN

EXISTING

EXPANSION

EXTERIOR

EACH WAY

±

Ø

ACC

ACI

ACT

AD, ADMIN

ADA

ADJ

AC

AFF

ALT

AL, ALUM

ARCH

BLDG

BD, BRD.

BLKG

BM

B.O.

B.O.B.

BTWN

C.J.

CL

CLG

CLR

CMU

COL

CONC

CONT

CORR

CPT

CT

CTRD

D

DB

DBL

DCTN

DEG

DTL

DHM

DIA

DIM

DN

DR

DS

DWG

DW

EA

EDF

EIFS

EJ

ELEC

ELEV

EQ

ETR

EXIST

EXP

EXT

EW

FD

FE

FEC

FF, FIN. FLR.

FG

FHC

FIN

FLR

FO

FR

FRTW

FT

FV

GA

GALV

GBF

GBP

GC

GUT

GYP.

GWB

H/C

HDW

HGT, HT

HM

HORIZ

HR

HWY

IBC

IN

INSUL

JST

JT

LAV

MB

MAX

MECH

MFR

MIN

M.O.

MPE

MTD

MTL

NFPA

NLB

NO

N.T.S.

O.C.

OCC

OFCI

OFOI

OH, OPP HD

PLT

PLAM

PLUMB

PLYWD

PSI

PT, PTD

PVC

PREP

PR, PRES

FLOOR DRAIN

FIRE EXTINGUISHER (WALL MOUNTED)

FIRE EXTINGUISHER CABINET

FINISH FLOOR

FINISH GRADE

FIRE HOSE CABINET

FINISH

FLOOR

FACE OF

FIRE RATED

FIRE RATED TREATED WOOD

FEET, FOOT

FIELD VERIFY

GAUGE

GALVANIZED

GYPSUM BOARD FURRING

GYPSUM BOARD PARTITION

GENERAL CONTRACTOR

GUTTER

GYPSUM

GYPSUM WALL BOARD

HANDICAP

HARDWARE

HEIGHT

HOLLOW METAL

HORIZONTAL

HOUR

HIGHWAY

INTERNATIONAL BUILDING CODE 2003 EDITION

INCH(ES)

INSULATION

JOIST

JOINT

LAVATORY

MARKER BOARD

MAXIMUM

MECHANICAL

MANUFACTURER('S)

MINIMUM

MASONRY OPENING

MECHANICAL, PLUMBING, ELECTRICAL

MOUNTED

METAL

NATIONAL FIRE PROTECTION ASSOCIATION

NON LOAD BEARING

NUMBER

NOT TO SCALE

ON CENTER

OCCUPANT

OWNER FURNISHED CONTRACTOR INSTALLED

OWNER FURNISHED OWNER INSTALLED

OPPOSITE HAND

PLATE

PLASTIC LAMINATE

PLUMBING

PLYWOOD

POUNDS PER SQUARE INCH

PAINTED

POLYVINYL CHLORIDE

PREPARE

PRESSURE

R, RAD

RD

R&S

REC

REF

RE: , REFER

REINF

REQ'D

RJ

RM

R.O.

SCHED, SCHD

SECT

SEG

SF

SHTNG

SHT

SIM

SPEC(S)

SPEC'D

STC

STD

STF

STL

STOR

STRUC, STRUCT

SUSP

SQ

SYS

TAS

TB

TBTP

T.C.

T.C.C.

TEL

TLT

T.O.

T.O.F.

T.O.P.

T.O.S.

T.O.W.

TP

TS

TST

TYP.

TR

UL

U.N.O.

VCT

VERT

VER

VOS

W

W/

WC

WD

WDW

WH

WR

WWF

RADIUS

ROOF DRAIN

ROD AND SHELF

RECOMMENDATION(S)

REFRIGERATOR

REFERENCE

REINFORCING

REQUIRED

RUSTICATION JOINT

ROOM

ROUGH OPENING

SCHEDULED

SECTION

SEGREGATION

SQUARE FEET

SHEATHING

SHEET

SIMILAR

SPECIFICATIONS

SPECIFIED

SOUND TRANSMISSION CLASS

STANDARD

STAFF

STEEL

STORAGE

STRUCTURE/ STRUCTURAL

SUSPENDED

SQUARE

SYSTEM

TEXAS ACCESSIBILITY STANDARDS

TACK BOARD

TAPE BED TEXTURE & PAINT

TOP OF CURB

TOP OF CONCRETE

TELEPHONE

TOILET

TOP OF

TOP OF FLATWORK

TOP OF PARAPET

TOP OF STEEL

TOP OF WALL

TOP OF PAVING

TUBULAR STEEL

TRANSITION STRIP

TYPICAL

TREATED

UNDERWRITERS LABORATORIES

UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE

VERTICAL

VERIFY

VERIFY ON SITE

WASHER

WITH

WATER CLOSET

WOOD

WINDOW

WATER HEATER

WATER RESISTANT

WELDED WIRE FABRIC

ABBREVIATIONS:

SHEET NUMBER

SECTION NUMBER

DETAIL NUMBER

SHEET NUMBER

NEW SPOT ELEVATION

EXISTING HEIGHT

EXISTING HEIGHT

PROPOSED HEIGHT

PROPOSED HEIGHT

BENCH MARK

GLAZING TYPES TAG

A

1

KEYED NOTE TAG - DEMOLITION PLAN

ENLARGED PLAN

EXISTING AND NEW PARTITION TYPES TAG

1

KEYED NOTE TAG - FLOOR PLAN, REFLECTED CEILING PLAN,AND ELEVATION, SECTION & DETAILS

B

HOLLOW METAL TAG

EXISTING SPOT ELEVATION

A

TOILET ACCESSORIES TAG

WINDOW TAG

DOOR TAG

ROOM TAG

ROOM NAMEROOM NUMBER

COLUMN TAG

1

CEILING TAG

A

NORTH

SCHEDULE ID TAG

SHEET NUMBER

ELEVATION

ELEVATION NUMBER

101ROOM

A.0

E-1

EQUIPMENT TAG

100.00

100.00

101

0A-000

0A-000

0A-000

0A-000

X-XXX

TITLEXSCALE: 1/8" = 1'-0"

NEW PARTITION TYPES TAG

A1

AB E1 A1

T-1

SYMBOLS

PROJECT LOCATION:MESA BUILDING

VACINITY MAP

SHEET:

Copyright © 2

015

Vand

ergr

iff G

roup

Arc

hite

cts a

nd P

lanne

rs, A

.I.A.

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

VAND

ERGR

IFF GR

OUP

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

G-001

DATE

: 8/23

/2016

CO

VE

R S

HE

ET

UTPB MESA BUILDING DEMARC ROOMINTERIOR RENOVATION

4901 E UNIVERSITY BLVDODESSA, TEXAS 79762

DRAWING INDEXGENEREAL

G-001 COVER SHEET

ARCHITECTURAL

A-201 DEMOLITION FLOOR PLAN - GROUND FLOOR

A-202 DEMOLITION FLOOR PLAN - MEZZANINE LEVEL

A-301 FLOOR PLAN, REFLECTED CEILING PLAN - GROUND FLOOR

A-321 DETAILS

MECHANICAL

M-201 DEMOLITION FLOOR PLANS - MECHANICAL

M-301 FLOOR PLAN - MECHANICAL

M-401 FLOOR PLAN - MECHANICAL PIPING

PLUMBING

P-201 FLOOR PLANS - PLUMBING

ELECTRICAL

E-101 ELECTRICAL LEGEND AND DETAILS

E-201 DEMOLITION FLOOR PLANS - ELECTRICAL

E-301 FLOOR PLAN - LIGHTING

E-401 FLOOR PLAN - POWER & SPECIAL SYSTEMS

MEP ENGINEER:

MECHANICAL & ELECTRICAL CONSULTING ENGINEERSAGNEW ASSOCIATES, INC.

(806) 799-0753FAX:

LUBBOCK, TEXAS AUSTIN, TEXASPHONE:

(806) 799-2014 (512) 310-0750FAX:(512) 828-0753PHONE:

WWW.AGNEWASSOCIATES.COM

ARCHITECT: UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

NOTE TO CONTRACTOR AND SUB-CONTRACTOR:EVERY EFFORT HAS BEEN MADE TO MAKE THESE DOCUMENTS CONCISE AND COORDINATED, TODEFINE WORK IN THE MOST LOGICAL PLACE AND TO ELIMINATE REDUNDANCY. DO NOT PRESUMETHAT YOUR SCOPE OF WORK IS SINGULARLY DEFINED. YOUR SCOPE OF WORK IS DEFINEDTHROUGHOUT THE ENTIRE SET OF DRAWINGS AND SPECIFICATIONS AND IS NOT CONTAINED INJUST ONE SERIES OF DRAWINGS OR DIVISION OF SPECIFICATIONS. YOU MUST REVIEW THEENTIRE SET OF CONTRACT DOCUMENTS TO DETERMINE YOUR SCOPE OF WORK. NO ADDITIONALCOST SHALL BE ASSESSED TO THE OWNER FOR NOT UNDERSTANDING SCOPE OF WORK. IFCONFLICT OCCURS, CONTACT ARCHITECT OF RECORD PRIOR TO COMMENCEMENT OF WORK.

AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
DRAWING NUMBER & TITLE
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
8/23/16
CAD-31
Sticky Note
Unmarked set by CAD-31
Page 2: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

A-201A DEMOLITION FLOOR PLAN - GROUND FLOOR

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

24

3

1

2

4

2

7

2 997

87

2

3

3

1

1

5

4

4

6

8 9

D

12

12

12

12

10

13

13

114

3

113 3 3

3

3

3

A-201B PHOTOGRAPH REFERENCE FLOOR PLAN - GROUND FLOOR

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

1.23

1.12E

1.21

1.01

1.14

E

1.29

J 1.15

1.30 J

F

1.31J

1.32J1.13E

1.08 B

1.06B

1.17 F

1.27

J 1.28 J

1.16 F

1.07

B

1.36

J

1.35

J1.18

G1.26

J

1.03A

1.04A

1.05

A

1.20H

1.33

J

1.19 H

1.24 J

1.02A

1.25J

1.34

J

1.22

1.37 K

8 9

D

F

SHEET:

Copy

right

© 2

015

Vand

ergr

iff G

roup

Arc

hite

cts a

nd P

lanne

rs, A

.I.A.

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

VAND

ERGR

IFF GR

OUP

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

A-201

DATE

: 8/23

/2016

DE

MO

LIT

ION

FL

OO

R P

LA

N -

GR

OU

ND

FL

OO

R

1. DEMOLISH THE EXISTING WOOD FRAMED PARTITION WITH GYPSUM BOARD AND PLYWOOD FINISH. REFER TO MEP DRAWINGSFOR ANY LIGHT SWITCHES, POWER OUTLETS OR MECHANICAL DEVICES THAT WILL NEED TO BE ELIMINATED OR RELOCATED.REFER TO PHOTO 1.01 WHICH ADDRESSES THE FOLLOWING EXISTING CONDITIONS IN AND WITH THIS PARTITION:

CONDITION A: EXISTING ELECTRICAL PANEL SERVING THE SPACE IS MOUNTED TO THE PARTITION TO BE DEMOLISHED. PROVIDE TEMPORARY SUPPORT FOR THE ELECTRICAL PANEL AND ASSOCIATED CONDUITS UNTIL NEW PERMANENT SUPPORT IS INSTALLED. REFER TO PHOTOS 1.02, 1.03, 10.4 AND 1.05.

CONDITION B: EXISTING TELECOMMUNICATIONS EQUIPMENT IS MOUNTED TO THE PLYWOOD WHICH IS SECURED TO THE PARTITION TO BE DEMOLISHED. PROVIDE TEMPORARY SUPPORT FOR THE PLYWOOD BACK BOARD UNTIL NEW PERMANENT SUPPORT IS INSTALLED. REFER TO PHOTOS 1.06, 1.07 AND 1.08

2. PROVIDE AND INSTALL TEMPORARY DUST PROTECTION FOR THE OWNER'S TELECOMMUNICATION EQUIPMENT.CONDITION D: NOT USED.

CONDITION E: FREESTANDING TELECOM EQUIPMENT. REFER TO PHOTOS 1.12, 1.13 AND 1.14

CONDITION F: WALL MOUNTED TELECOM EQUIPMENT. REFER TO PHOTO 1.15, 1.16, 1.17 AND 1.26.

CONDITION G: FREESTANDING TELECOM EQUIPMENT RACK. REFER TO PHOTOS 1.18

CONDITION H: FREESTANDING TELECOM EQUIPMENT RACK, WORK STATION AND WALL MOUNTEDEQUIPMENT. REFER TO PHOTOS 1.19 AND 1.20.

3. DEMOLISH THE EXISTING MEZZANINE FLOOR SYSTEM (LEVEL #2) INCLUDING THE 2X FLOOR JOISTS, 3/4" PLYWOOD DECKING ANDPULL DOWN ATTIC STAIR. WALL MOUNTED SUPPORT LEDGER & 2X VERTICAL SUPPORTS TO REMAIN. PAINT EXISTING WALLMOUNTED 2x FRAMING WITH FIRE RETARDANT PAINT. REFER TO MEP DRAWINGS FOR EXISTING LIGHT FIXTURE ANDMECHANICAL DUCTWORK (AND EQUIPMENT) THAT WILL BE ELIMINATED WITH THE DEMOLITION OF THE LEVEL #2 FLOOR SYSTEM.REFER TO PHOTOS 1.21, 1.22 AND 1.23. ADDRESS THE FOLLOWING CONDITIONS WITH THE REMOVAL OF THE SECOND LEVELFLOOR SYSTEM:

CONDITION J: PROVIDE TEMPORARY SUPPORT FOR WALL AND CEILING SUPPORTED CONDUITS,CABLING AND WIRING. REFER TO PHOTOS 1.24 THROUGH 1.36. NOTE: TEMPORARYSUPPORT FOR ANY OF THE OWNER'S TELECOM WIRING AND CABLING SHALL BEAPPROVED BY THE OWNER'S IT STAFF BEFORE IT IS REMOVED FROM ITS EXISTINGSUPPORT.

CONDITION K: VERIFY NEW SUPPORT METHOD AND POSITIONING OF OWNER'S EXISTING CEILINGMOUNTED SECURITY EQUIPMENT WITH CAMERA BEFORE REMOVING.REFER TO PHOTO 1.37.

4. OWNER'S TELECOMMUNICATION EQUIPMENT TO REMAIN. (CONDITION E)(PHOTOS 1.12,1.13 AND 1.14)5. EXISTING ELECTRICAL PANEL. (CONDITION A)(PHOTOS 1.03,1.05 AND 1.25)6. EXISTING FIRST FLOOR MECHANICAL UNIT; REFER TO MEP DRAWINGS FOR ADDITIONS AND REVISIONS.7. EXISTING OVERHEAD CABLE RACK SYSTEM TO REMAIN. ALL EXISTING CABLE RACKS ARE SUPPORTED AT THE FREESTANDING

TELECOMMUNICATIONS RACK. (PHOTOS 1.09, 1.15, 1.16, 1.18, 1.26, 1.28, 1.29 AND 1.30)8. FREESTANDING TELECOMMUNICATION RACK TO REMAIN. (PHOTOS 1.08, 1.16 AND 1.18)9. WALL MOUNTED TELECOMMUNICATIONS EQUIPMENT TO REMAIN. (CONDITION F)(PHOTOS 1.15,1.16 AND 1.17)10. WALL MOUNTED TELECOMMUNICATIONS EQUIPMENT THAT WILL REQUIRE NEW SUPPORT ONCE PARTITION IS DEMOLISHED.

REFER TO KEYED NOTE #1. (CONDITION B) (PHOTOS 1.06, 1.07 AND 1.08)11. SAW-CUT, REMOVE AND ALTER OPENING IN EXISTING 8" CMU WALL PARTITION AS REQUIRED TO INSTALL NEW ACCESS DOOR.12. ALL EXISTING LIGHT FIXTURES SHALL BE REMOVED AND NEW LIGHT FIXTURES PROVIDED PER ELECTRICAL DRAWINGS AND

SPECIFICATIONS.13. REMOVE THE EXISTING HVAC ROUND DUCT AND WALL GRILLE. REFER TO SECOND FLOOR DEMOLITION FLOOR PLAN AND THE

MECHANICAL DRAWINGS. (PHOTOS 1.01, 1.02, 1.04 AND 1.25)14. EXISTING CAST IRON VENT LINE TO REMAIN.

CONDITION L: (PHOTOS 2.02, 2.03, 2.22 AND 2.23).

15. REMOVE EXISTING GLAZING FROM TRANSOM ABOVE EXISTING ENTRANCE DOORS. REFER TO A/A-301 FLOOR PLAN; EXISTINGGLAZING TO BE REPLACED WITH INSULATED METAL PANEL. (PHOTO 2.37)

16. REMOVE EXISTING SUSPENDED DOMESTIC WATER PIPING, REPLACE AND RELOCATE. REFER TO PLUMBING DRAWINGS ANDSPECIFICATIONS.

CONDITION M: (PHOTOS 2.01, 2.03, 2.04, 2.05, 2.06, 2.08, 2.09, 2.13, 2.14, 2.18, 2.19, 2.20, 2.24, 2.29, 2.30 AND 2.37)

17. REMOVE THE EXISTING HVAC MECHANICAL UNIT ON MEZZANINE FLOOR LEVEL AND ALL ASSOCIATED DUCTWORK SERVING THEFIRST FLOOR. REFER TO MEP DRAWINGS. (PHOTOS 2.09, 2.10, 2.12, 2.13, 2.24, 2.25, 2.26, 2.27, 2.29, 2.32 AND 2.37)

18. CAP AND TERMINATE ON THE OPPOSITE SIDE OF THE 8" CMU PARTITION, ALL DUCTWORK SERVING THE DEMARC ROOM FROMTHE "BUILDING HVAC SYSTEM". REFER TO MEP DRAWINGS. (PHOTOS 2.01, 2.03, 2.04, 2.06, 2.09, 2.10, 2.11, 2.12, 2.13, 2.14 AND 2.28)

19. RELOCATE EXISTING WALL MOUNTED ELECTRICAL BOXES TO CLEAR NEW TWO (2) HOUR FURR-DOWN. (PHOTOS 2.06, 2.14 AND2.28)

20. RELOCATED AND REROUTE EXISTING ELECTRICAL CONDUIT PENETRATING EXISTING 8" CMU WALL AT EXISTING SUPPLY DUCTTO CLEAR NEW TWO (2) HOUR FURR-DOWN. (PHOTOS 20.9, 2.10 AND 2.11)

21. REMOVE ANY EXPOSED WOOD FRAMING, BLOCKING, ETC. ATTACHED TO THE UNDERSIDE OF THE EXISTING CONCRETE DECK.(PHOTOS 2.13, 2.24, 2.25, 2.26, 2.29, 2.30 AND 2.37)

22. REMOVE PORTION OF EXISTING CMU PARTITION AS REQUIRED TO CREATE OPENING TO ACCOMMODATERELOCATED/REROUTED DOMESTIC WATER AND LEAK TRAY, REFER TO MEP DRAWINGS.

23. EXISTING MECHANICAL DUCTWORK TO REMAIN.24. OWNER'S EXISTING EQUIPMENT TO BE REPOSITIONED BY OWNER'S SUB-CONTRACTOR.25. EXISTING EXHAUST DUCT TO BE REMOVED; REFER TO MECHANICAL.

DEMOLITION NOTES:1. THE FINISH ON THE EXISTING CMU WALLS HAS TESTED POSITIVE FOR ASBESTOS

MATERIAL. THE OWNER HAS HAD SELECTIVE ABATEMENT PERFORMED IN THOSEAREAS DIRECTLY RELATED TO THE WORK INDICATED ON THE DRAWINGS. IF THEGENERAL CONTRACTOR DETERMINES THAT THE WORK WILL REQUIREDISTURBING THE EXISTING WALL FINISH IN AREAS OTHER THAN THOSE AREASWHERE SELECTIVE ABATEMENT HAS BEEN PERFORMED, HE SHALL CEASE THEWORK IN THAT AREA AND CONTACT THE ARCHITECT AND THE OWNER.

2. NO DEMOLITION WORK SHALL START UNTIL ALL THE OWNER'S TELECOM/DATA EQUIPMENT HAS BEEN PROTECTED ASINDICATED ON THE CONSTRUCTION DRAWINGS.

3. NO DEMOLITION WORK SHALL START UNTIL THE GENERAL CONTRACTOR, THE OWNER AND THE ARCHITECT HAS REVIEWEDTHE WORK AND IDENTIFIED CONDITIONS.

4. PHOTOS OF EXISTING CONDITIONS ARE PROVIDED AND INCLUDED IN THE BACK OF THE PROJECT MANUAL FOR THE GENERALCONTRACTOR'S REFERENCE AND INFORMATION. THE PHOTOS ARE NUMBERED AND REFERENCED ON THE ATTACHEDPHOTOGRAPH REFERENCE FLOOR PLAN.

5. DEMOLITION WORK IS SPECIFIC AND SENSITIVE IN NATURE. GENERAL CONTRACTOR SHALL BE DILIGENT AND CAUTIOUSDURING THE DEMOLITION PROCESS. ANY WORK PERFORMED IN THE DEMARC ROOM MUST BE PERSONALLY SUPERVISEDAND/OR PERFORMED BY/OR WITH THE SUPERVISION OF THE GENERAL CONTRACTOR'S APPROVED SUPERINTENDENTPRESENT.

6. ANY EXISTING EXPOSED WOOD FRAMING, BLOCKING, SUPPORT LEDGERS, ETC. REMAINING AND SECURED DIRECTLY TO THEEXISTING CMU WALLS SHALL REMAIN AND BE PAINTED WITH INTUMESCENT FIRE PROOFING.

7. ANY ELECTRICAL CONDUIT, DATA WIRING, TELEPHONE OR DATA BOXES, ETC. THAT IS MOUNTED OR SUPPORTED BY ANYWALLS OR CEILING/DECK STRUCTURAL MEMBERS SCHEDULED TO BE DEMOLISHED SHALL BE SUPPORTED ON A TEMPORARYBASIS UNTIL A PERMANENT MEANS OF SUPPORT CAN BE PROVIDED AND INSTALLED. ANY TEMPORARY SUPPORT ORREMOUNTING OF ANY EXISTING TELECOM OR DATA WIRING OR DEVICES SHALL BE REVIEWED AND DISCUSSED WITH THEOWNER'S REPRESENTATIVE BEFORE ANY WORK IS STARTED.

8. ALL PENETRATIONS IN THE EXISTING CMU WALLS OF THE NEW DEMARC ROOM (EXCLUDING AREAS ENCLOSED WITH THE NEWTWO HOUR RATED SHAFT WALL FURR-DOWN) SHALL HAVE TWO HOUR FIRE BARRIERDEVICES, WRAP STRIPS, PUTTY,SEALANT, ETC. INSTALLED AS INDICATED ON THE DRAWINGS AS WELL AS ANY PENETRATIONS NOT SPACIFICALLY NOTED ONTHE DRAWINGS.

GENERAL DEMOLITION NOTES:

KEY PLANSCALE: N.T.S.

TRUENORTH

PLANNORTH

MESA BUILDING

PHOTOGRAPHS REFERENCE PLAN LEGEND:A 1.00

PHOTO IDENTIFICATION TAG (PHOTOS LOCATED IN BACK OF PROJECT MANUAL)

CONDITION NUMBER (REFERENCE DEMOLITION NOTES)

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AutoCAD SHX Text
8/23/16
CAD-31
Sticky Note
Unmarked set by CAD-31
Page 3: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

8 9

D

A-202A DEMOLITION FLOOR PLAN - MEZZANINE FLOOR

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

23

25

23

1514

14

3

12

3

3

3

12

12

21

21

21

16

16

17

17

16

17

16

17

17

22

18 18 18

2019

8 9

D

2.26

2.35

2.342.33 2.32

2.36

2.13 2.1

2

2.30M

2.18M

2.20

2.29

2.09

2.10

2.112.07

2.19

2.27 2.21

2.23

2.16

2.22

2.17

2.06

2.05

M

2.14

2.28

2.31

2.03

2.01

M

2.02

L

2.15

2.04

M2.0

8L

M

M

M

M

M

M

M

L

L

2.24

M

2.25

2.37M

A-202B PHOTOGRAPH REFERENCE FLOOR PLAN - MEZZANINE FLOOR

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

M

M

SHEET:

Copy

right

© 2

015

Vand

ergr

iff G

roup

Arc

hite

cts a

nd P

lanne

rs, A

.I.A.

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

VAND

ERGR

IFF GR

OUP

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

A-202

DATE

: 8/23

/2016

DE

MO

LIT

ION

FL

OO

R P

LA

N -

ME

ZZ

AN

INE

LE

VE

L

DEMOLITION NOTES: GENERAL DEMOLITION NOTES:

PHOTOGRAPHS REFERENCE PLAN LEGEND:

KEY PLANSCALE: N.T.S.

TRUENORTH

PLANNORTH

MESA BUILDING

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

A 1.00PHOTO IDENTIFICATION TAG (PHOTOS LOCATED IN BACK OF PROJECT MANUAL)

CONDITION NUMBER (REFERENCE DEMOLITION NOTES)

1. THE FINISH ON THE EXISTING CMU WALLS HAS TESTED POSITIVE FOR ASBESTOSMATERIAL. THE OWNER HAS HAD SELECTIVE ABATEMENT PERFORMED IN THOSEAREAS DIRECTLY RELATED TO THE WORK INDICATED ON THE DRAWINGS. IF THEGENERAL CONTRACTOR DETERMINES THAT THE WORK WILL REQUIREDISTURBING THE EXISTING WALL FINISH IN AREAS OTHER THAN THOSE AREASWHERE SELECTIVE ABATEMENT HAS BEEN PERFORMED, HE SHALL CEASE THEWORK IN THAT AREA AND CONTACT THE ARCHITECT AND THE OWNER.

2. NO DEMOLITION WORK SHALL START UNTIL ALL THE OWNER'S TELECOM/DATA EQUIPMENT HAS BEEN PROTECTED ASINDICATED ON THE CONSTRUCTION DRAWINGS.

3. NO DEMOLITION WORK SHALL START UNTIL THE GENERAL CONTRACTOR, THE OWNER AND THE ARCHITECT HAS REVIEWEDTHE WORK AND IDENTIFIED CONDITIONS.

4. PHOTOS OF EXISTING CONDITIONS ARE PROVIDED AND INCLUDED IN THE BACK OF THE PROJECT MANUAL FOR THE GENERALCONTRACTOR'S REFERENCE AND INFORMATION. THE PHOTOS ARE NUMBERED AND REFERENCED ON THE ATTACHEDPHOTOGRAPH REFERENCE FLOOR PLAN.

5. DEMOLITION WORK IS SPECIFIC AND SENSITIVE IN NATURE. GENERAL CONTRACTOR SHALL BE DILIGENT AND CAUTIOUSDURING THE DEMOLITION PROCESS. ANY WORK PERFORMED IN THE DEMARC ROOM MUST BE PERSONALLY SUPERVISEDAND/OR PERFORMED BY/OR WITH THE SUPERVISION OF THE GENERAL CONTRACTOR'S APPROVED SUPERINTENDENTPRESENT.

6. ANY EXISTING EXPOSED WOOD FRAMING, BLOCKING, SUPPORT LEDGERS, ETC. REMAINING AND SECURED DIRECTLY TO THEEXISTING CMU WALLS SHALL REMAIN AND BE PAINTED WITH INTUMESCENT FIRE PROOFING.

7. ANY ELECTRICAL CONDUIT, DATA WIRING, TELEPHONE OR DATA BOXES, ETC. THAT IS MOUNTED OR SUPPORTED BY ANYWALLS OR CEILING/DECK STRUCTURAL MEMBERS SCHEDULED TO BE DEMOLISHED SHALL BE SUPPORTED ON A TEMPORARYBASIS UNTIL A PERMANENT MEANS OF SUPPORT CAN BE PROVIDED AND INSTALLED. ANY TEMPORARY SUPPORT ORREMOUNTING OF ANY EXISTING TELECOM OR DATA WIRING OR DEVICES SHALL BE REVIEWED AND DISCUSSED WITH THEOWNER'S REPRESENTATIVE BEFORE ANY WORK IS STARTED.

8. ALL PENETRATIONS IN THE EXISTING CMU WALLS OF THE NEW DEMARC ROOM (EXCLUDING AREAS ENCLOSED WITH THE NEWTWO HOUR RATED SHAFT WALL FURR-DOWN) SHALL HAVE TWO HOUR FIRE BARRIERDEVICES, WRAP STRIPS, PUTTY,SEALANT, ETC. INSTALLED AS INDICATED ON THE DRAWINGS AS WELL AS ANY PENETRATIONS NOT SPACIFICALLY NOTED ONTHE DRAWINGS.

1. DEMOLISH THE EXISTING WOOD FRAMED PARTITION WITH GYPSUM BOARD AND PLYWOOD FINISH. REFER TO MEP DRAWINGSFOR ANY LIGHT SWITCHES, POWER OUTLETS OR MECHANICAL DEVICES THAT WILL NEED TO BE ELIMINATED OR RELOCATED.REFER TO PHOTO 1.01 WHICH ADDRESSES THE FOLLOWING EXISTING CONDITIONS IN AND WITH THIS PARTITION:

CONDITION A: EXISTING ELECTRICAL PANEL SERVING THE SPACE IS MOUNTED TO THE PARTITION TO BE DEMOLISHED. PROVIDE TEMPORARY SUPPORT FOR THE ELECTRICAL PANEL AND ASSOCIATED CONDUITS UNTIL NEW PERMANENT SUPPORT IS INSTALLED. REFER TO PHOTOS 1.02, 1.03, 10.4 AND 1.05.

CONDITION B: EXISTING TELECOMMUNICATIONS EQUIPMENT IS MOUNTED TO THE PLYWOOD WHICH IS SECURED TO THE PARTITION TO BE DEMOLISHED. PROVIDE TEMPORARY SUPPORT FOR THE PLYWOOD BACK BOARD UNTIL NEW PERMANENT SUPPORT IS INSTALLED. REFER TO PHOTOS 1.06, 1.07 AND 1.08

2. PROVIDE AND INSTALL TEMPORARY DUST PROTECTION FOR THE OWNER'S TELECOMMUNICATION EQUIPMENT.CONDITION D: NOT USED.

CONDITION E: FREESTANDING TELECOM EQUIPMENT. REFER TO PHOTOS 1.12, 1.13 AND 1.14

CONDITION F: WALL MOUNTED TELECOM EQUIPMENT. REFER TO PHOTO 1.15, 1.16, 1.17 AND 1.26.

CONDITION G: FREESTANDING TELECOM EQUIPMENT RACK. REFER TO PHOTOS 1.18

CONDITION H: FREESTANDING TELECOM EQUIPMENT RACK, WORK STATION AND WALL MOUNTEDEQUIPMENT. REFER TO PHOTOS 1.19 AND 1.20.

3. DEMOLISH THE EXISTING MEZZANINE FLOOR SYSTEM (LEVEL #2) INCLUDING THE 2X FLOOR JOISTS, 3/4" PLYWOOD DECKING ANDPULL DOWN ATTIC STAIR. WALL MOUNTED SUPPORT LEDGER & 2X VERTICAL SUPPORTS TO REMAIN. PAINT EXISTING WALLMOUNTED 2x FRAMING WITH FIRE RETARDANT PAINT. REFER TO MEP DRAWINGS FOR EXISTING LIGHT FIXTURE ANDMECHANICAL DUCTWORK (AND EQUIPMENT) THAT WILL BE ELIMINATED WITH THE DEMOLITION OF THE LEVEL #2 FLOOR SYSTEM.REFER TO PHOTOS 1.21, 1.22 AND 1.23. ADDRESS THE FOLLOWING CONDITIONS WITH THE REMOVAL OF THE SECOND LEVELFLOOR SYSTEM:

CONDITION J: PROVIDE TEMPORARY SUPPORT FOR WALL AND CEILING SUPPORTED CONDUITS,CABLING AND WIRING. REFER TO PHOTOS 1.24 THROUGH 1.36. NOTE: TEMPORARYSUPPORT FOR ANY OF THE OWNER'S TELECOM WIRING AND CABLING SHALL BEAPPROVED BY THE OWNER'S IT STAFF BEFORE IT IS REMOVED FROM ITS EXISTINGSUPPORT.

CONDITION K: VERIFY NEW SUPPORT METHOD AND POSITIONING OF OWNER'S EXISTING CEILINGMOUNTED SECURITY EQUIPMENT WITH CAMERA BEFORE REMOVING.REFER TO PHOTO 1.37.

4. OWNER'S TELECOMMUNICATION EQUIPMENT TO REMAIN. (CONDITION E)(PHOTOS 1.12,1.13 AND 1.14)5. EXISTING ELECTRICAL PANEL. (CONDITION A)(PHOTOS 1.03,1.05 AND 1.25)6. EXISTING FIRST FLOOR MECHANICAL UNIT; REFER TO MEP DRAWINGS FOR ADDITIONS AND REVISIONS.7. EXISTING OVERHEAD CABLE RACK SYSTEM TO REMAIN. ALL EXISTING CABLE RACKS ARE SUPPORTED AT THE FREESTANDING

TELECOMMUNICATIONS RACK. (PHOTOS 1.09, 1.15, 1.16, 1.18, 1.26, 1.28, 1.29 AND 1.30)8. FREESTANDING TELECOMMUNICATION RACK TO REMAIN. (PHOTOS 1.08, 1.16 AND 1.18)9. WALL MOUNTED TELECOMMUNICATIONS EQUIPMENT TO REMAIN. (CONDITION F)(PHOTOS 1.15,1.16 AND 1.17)10. WALL MOUNTED TELECOMMUNICATIONS EQUIPMENT THAT WILL REQUIRE NEW SUPPORT ONCE PARTITION IS DEMOLISHED.

REFER TO KEYED NOTE #1. (CONDITION B) (PHOTOS 1.06, 1.07 AND 1.08)11. SAW-CUT, REMOVE AND ALTER OPENING IN EXISTING 8" CMU WALL PARTITION AS REQUIRED TO INSTALL NEW ACCESS DOOR.12. ALL EXISTING LIGHT FIXTURES SHALL BE REMOVED AND NEW LIGHT FIXTURES PROVIDED PER ELECTRICAL DRAWINGS AND

SPECIFICATIONS.13. REMOVE THE EXISTING HVAC ROUND DUCT AND WALL GRILLE. REFER TO SECOND FLOOR DEMOLITION FLOOR PLAN AND THE

MECHANICAL DRAWINGS. (PHOTOS 1.01, 1.02, 1.04 AND 1.25)14. EXISTING CAST IRON VENT LINE TO REMAIN.

CONDITION L: (PHOTOS 2.02, 2.03, 2.22 AND 2.23).

15. REMOVE EXISTING GLAZING FROM TRANSOM ABOVE EXISTING ENTRANCE DOORS. REFER TO A/A-301 FLOOR PLAN; EXISTINGGLAZING TO BE REPLACED WITH INSULATED METAL PANEL. (PHOTO 2.37)

16. REMOVE EXISTING SUSPENDED DOMESTIC WATER PIPING, REPLACE AND RELOCATE. REFER TO PLUMBING DRAWINGS ANDSPECIFICATIONS.

CONDITION M: (PHOTOS 2.01, 2.03, 2.04, 2.05, 2.06, 2.08, 2.09, 2.13, 2.14, 2.18, 2.19, 2.20, 2.24, 2.29, 2.30 AND 2.37)

17. REMOVE THE EXISTING HVAC MECHANICAL UNIT ON MEZZANINE FLOOR LEVEL AND ALL ASSOCIATED DUCTWORK SERVING THEFIRST FLOOR. REFER TO MEP DRAWINGS. (PHOTOS 2.09, 2.10, 2.12, 2.13, 2.24, 2.25, 2.26, 2.27, 2.29, 2.32 AND 2.37)

18. CAP AND TERMINATE ON THE OPPOSITE SIDE OF THE 8" CMU PARTITION, ALL DUCTWORK SERVING THE DEMARC ROOM FROMTHE "BUILDING HVAC SYSTEM". REFER TO MEP DRAWINGS. (PHOTOS 2.01, 2.03, 2.04, 2.06, 2.09, 2.10, 2.11, 2.12, 2.13, 2.14 AND 2.28)

19. RELOCATE EXISTING WALL MOUNTED ELECTRICAL BOXES TO CLEAR NEW TWO (2) HOUR FURR-DOWN. (PHOTOS 2.06, 2.14 AND2.28)

20. RELOCATED AND REROUTE EXISTING ELECTRICAL CONDUIT PENETRATING EXISTING 8" CMU WALL AT EXISTING SUPPLY DUCTTO CLEAR NEW TWO (2) HOUR FURR-DOWN. (PHOTOS 20.9, 2.10 AND 2.11)

21. REMOVE ANY EXPOSED WOOD FRAMING, BLOCKING, ETC. ATTACHED TO THE UNDERSIDE OF THE EXISTING CONCRETE DECK.(PHOTOS 2.13, 2.24, 2.25, 2.26, 2.29, 2.30 AND 2.37)

22. REMOVE PORTION OF EXISTING CMU PARTITION AS REQUIRED TO CREATE OPENING TO ACCOMMODATERELOCATED/REROUTED DOMESTIC WATER AND LEAK TRAY, REFER TO MEP DRAWINGS.

23. EXISTING MECHANICAL DUCTWORK TO REMAIN.24. OWNER'S EXISTING EQUIPMENT TO BE REPOSITIONED BY OWNER'S SUB-CONTRACTOR.25. EXISTING EXHAUST DUCT TO BE REMOVED; REFER TO MECHANICAL.

AutoCAD SHX Text
8/23/16
CAD-31
Sticky Note
Unmarked set by CAD-31
CAD-31
Sticky Note
Unmarked set by CAD-31
Page 4: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

8 9

D

A-301A FLOOR PLAN

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

VESTIBULE

1A-321

1

1

2

22

9

4

3

3

2

6

773

8

A

B

1

9

11

10

11

12

14

6'-8"

2'-6"

10 1/

4"

7 3/8" 4'-9" 4'-9" 4'-9"

12

9'-8"

FIEL

D VE

RIFY

5'-4"CLEAR

1'-8 3/4"

1

8

101

3'-1 1

/2"

13

13

7'-10

"2

2A-321

3A-321

11

11

15

19

19

6'-2 3/8"

1'-1 1

/4"2'-

4"

4A-321

A-301B REFLECTED CEILNG PLAN

SCALE: 3/8" = 1'-0"

TRUENORTH

PLANNORTH

8 9

D

VESTIBULE

5A-321

5A-321

1A-321

5

5

10

5

5

11

11

2A-321

3A-321

20

20

20

11

1116 16

17

17

18

18

17

4A-321

FIN. FLR.EL. 100'-0"

4'-0"

7'-0" A

6" 6"

6"10

"

A-3011 DOOR ELEVATIONS

SCALE: 1/4" = 1'-0"

TYPE A

A

2'-2"

6"

3'-6"

4'-6"

FIEL

D VE

RIFY

2"6'-

10"

2"2"

2" 3'-11 1/2" 4 1/2"

4A-301

A

A

A-3012 ALUMINUM FRAME ELEVATION

SCALE: 1/4" = 1'-0"

5A-301

A

FIN. FLR.EL. 100'-0"

6A-301

FACE

OF

WAL

L

4A-301

SIM.

GLAZING LEGENDMARK THICK DESCRIPTION

A 1/4" 1/4" CLEAR TEMPERED GLAZING

A-3014

(HEAD SIM.)JAMB DETAIL

SCALE: 3" = 1'-0"

GLAZING AS SCHEDULED ANDSPECIFIED

ALUM. WINDOW SYSTEM ASSPECIFIED

CONT. CAULK JNT.; TYP. EA. SIDE

LINE INDICATES NEW 2-HR FIRERATED GYP. BRD. FURR-DOWN @HEAD CONDITION

2x BLOCKING AS REQUIRED

DRYWALL CORNER TRIM; TYP.

SHIMS AS REQUIRED

3 5/8" METAL STUDS @ 16" O.C.WITH 5/8" GYP. BRD. EA. SIDE. TAPEBED TEXTURE PAINT.

A-3015 SILL DETAIL

SCALE: 3" = 1'-0"

FIN. FLR.EL: 100'-0"

WINDOW SUB-SILL BYWINDOW MFGRSET IN BED OF SEALANT;TYP.

ALUM WINDOW FRAME ASSCHEDULED

FLOOR FINISH ASSCHEDULED

4 1/2"

ALUM WINDOW FRAME ASSCHEDULED

GLAZING AS SCHEDULEDAND SPECIFIED

A-3016 OUTSIDE CORNER DETAIL

SCALE: 3" = 1'-0"

6'-6 1/2"

2"4'-2"0"4 1/2"

6'-10

"2"

2"

FIEL

D VE

RIFY

A

DOOR ASSCHEDULED

5A-301

B

1'-8"2"

6A-301

SIM.

A

A

2"

FIN. FLR.EL. 100'-0"

6A-301

A-3013 ALUMINUM FRAME ELEVATION

SCALE: 1/4" = 1'-0"

FACE

OF

WAL

L

4A-301

4A-301

SIM.

SHEET:

Copy

right

© 2

015

Vand

ergr

iff G

roup

Arc

hite

cts a

nd P

lanne

rs, A

.I.A.

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

VAND

ERGR

IFF GR

OUP

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

A-301

DATE

: 8/23

/2016

FLO

OR

PL

AN

, RE

FLE

CT

ED

CE

ILIN

G P

LA

N -

GR

OU

ND

FL

OO

R

GENERAL NOTES:

1. NEW FLOOR MOUNTED UNISTRUT COMMERCIAL FRAMING SYSTEM ASSPECIFIED. PROVIDE AND INSTALL P2072ASQEG 2-HOLE POST BASE, P1000T PLUNISTRUT SLOTTED SINGLE CHANNEL FRAMING, AND ALL ASSOCIATEDFASTENING HARDWARE NEEDED FOR INSTALLATION. PROVIDE AND INSTALLEXPANSION BOLTS REQUIRED TO SECURE POST BASES TO EXISTING CONCRETEFLOOR SLAB.

2. EXISTING I.T./COMMUNICATIONS EQUIPMENT TO REMAIN. CONTRACTOR TOPROTECT EQUIPMENT FROM DAMAGE DURING CONSTRUCTION AND DEMOLITIONPROCESS SO THAT NOW DAMAGE SHALL OCCUR TO THE EQUIPMENT. CONSULTWITH OWNER'S REPRESENTATIVE AND PROVIDE DUST PROTECTION ASINDICATED.

3. LINE OF NEW FIRE-RATED GYP. BRD. FURR-DOWN ABOVE.4. NEW MECHANICAL UNITS. RE: MECHANICAL.5. NEW FIRE RATED GYP. BRD. FURR-DOWN. RE: DETAILS.6. EXISTING ELECTRICAL PANEL AND CONDUIT TO REMAIN; PROVIDE TEMPORARY

SUPPORT FOR PANEL AND CONDUIT DURING DEMOLITION OF MEZZANINE ANDSECURE EXISTING ELECTRICAL PANEL TO NEW UNISTRUT COMMERCIALFRAMING AFTER INSTALLATION. TEMPORARY SUPPORT SHOULD NOT INTERFEREWITH THE INSTALLATION OF NEW UNISTRUT SYSTEM.

7. PROVIDE TEMPORARY SUPPORT FOR THE EXISTING PLYWOOD ANDCOMMUNICATIONS EQUIPMENT, THIS AREA, DURING DEMOLITION OF WOODFRAMED WALLS AND SECURE TO NEW UNISTRUT COMMERCIAL FRAMINGSYSTEM AFTER INSTALLATION. TEMPORARY SUPPORT SHOULD NOT INTERFEREWITH THE INSTALLATION OF NEW UNISTRUT SYSTEM.

8. PROVIDE AND INSTALL NEW 24"w X 48"h 90 MIN. FIRE RATED ACCESS DOOR ATEXISTING OPENING IN THE CMU WALL. PROVIDE AND INSTALL A NEW 3"x5"x1/4"STEEL LINTEL AT OPENING TO SUPPORT EXISTING STACK BOND CMU BLOCK.

9. EXISTING I.T./COMMUNICATIONS EQUIPMENT WIRE RACK/TRAY TO REMAIN.10. PROVIDE AND INSTALL NEW UNISTRUT COMMERCIAL FRAMING SYSTEM,

INCLUDING BUT NOT LIMITED TO, ATHR-T-1/2-10 EG 1/2x13 THREADED ROD CUTTO LENGTH, P1000T PL UNISTRUT SLOTTED SINGLE CHANNEL FRAMING CUT TOLENGTH, ETC. TO SUPPORT THE EXISTING ELECTRICAL CONDUITS. SECURE ANDSUSPEND UNISTRUT COMMERCIAL FRAMING SYSTEM FROM THEPOURED-IN-PLACE CONCRETE FRAMING ABOVE.

11. PROVIDE AND INSTALL NEW UNISTRUT COMMERCIAL FRAMING SYSTEM,INCLUDING BUT NOT LIMITED TO, P2072ASQEG 2-HOLE POST BASE, P1000T PLUNISTRUT SLOTTED SINGLE CHANNEL FRAMING, UC2946EG 18" SINGLE CHANNELBRACKET TO SUPPORT NEW WIRE TRAY FOR THE EXISTING I.T./COMMUNICATIONWIRING ALONG PERIMETER OF ROOM. PROVIDE AND INSTALL EXPANSION BOLTSREQUIRED TO SECURE AND SUSPEND UNISTRUT COMMERCIAL FRAMINGSYSTEM FROM THE POURED-IN-PLACE CONCRETE FRAMING ABOVE. PROVIDE 6"BETWEEN WALL SURFACE AND EDGE OF WIRE TRAY.

12. PROVIDE AND INSTALL NEW ALUMINUM STOREFRONT ENTRY SYSTEM ASSPECIFIED AND DETAILED

13. PROVIDE AND INSTALL NEW 3 5/8" METAL STUD WALL WITH 5/8" GYP. BRD. FINISHATTACHED TO EXISTING CMU WALL. TAPE, BED, TEXTURE, AND PAINT.

14. OWNER'S TELECOM/DATA EQUIPMENT RELOCATED/ REPOSITIONED BY OWNER.15. PROVIDE AND INSTALL NEW 5/16" THICK INSULATED METAL PANEL IN EXISTING

HOLLOW METAL TRANSOM FRAME. FIELD VERIFY SIZE OF OPENING PRIOR TOINSTALLATION. COLOR TO MATCH EXISTING FRAME.

16. PROVIDE AND INSTALL NEW WALL MOUNTED UNISTRUT COMMERCIAL FRAMINGSYSTEM INCLUDING BUT NOT LIMITED TO, UC2946EG 18" SINGLE CHANNELBRACKET, WIRE TRAY, ETC. TO ACCOMMODATE THE EXISTINGI.T./COMMUNICATION WIRING ALONG PERIMETER OF ROOM. PROVIDE ANDINSTALL EXPANSION BOLTS REQUIRED TO SECURE SINGLE CHANNEL BRACKETTO EXISTING CMU WALL.

17. EXISTING CABLING TO REMAIN ON EXISTING WALL SUPPORTS.18. PROVIDE AND INSTALL THROUGH WALL, FIRE RATED CABLE PATHWAY AS

SPECIFIED; VERIFY NUMBER REQUIRED PER AMOUNT OF CABLES TO BEACCOMMODATED.

19. PREP AND REPAINT THE EXISTING OVER SIZED HOLLOW METAL FRAME ANDHOLLOW METAL DOOR, EXTERIOR AND INTERIOR SURFACES.

20. PROVIDE AND INSTALL THROUGH WALL, FIRE RATED CABLE PATHWAY ASSPECIFIED; VERIFY NUMBER REQUIRED PER AMOUNT OF CABLES TO BEACCOMMODATED.

KEYED NOTES:

KEY PLANSCALE: N.T.S.

TRUENORTH

PLANNORTH

MESA BUILDING

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

DOOR SCHEDULE

MARKWD HGT THK

SIZEMATL TYPE GLAZE

DOOR

MATL ELHEAD JAMB SILL

DETAIL

FRAME

RATING SET NO NOTES

101 4'-0" 7'-0" 1 3/4" ALUM. A A ALUM. B 4/A-301 4/A-301 - - - -

1. THE FINISH ON THE EXISTING CMU WALLS HASTESTED POSITIVE FOR ASBESTOS MATERIAL. THEOWNER HAS HAD SELECTIVE ABATEMENTPERFORMED IN THOSE AREAS DIRECTLY RELATEDTO THE WORK INDICATED ON THE DRAWINGS. IF THEGENERAL CONTRACTOR DETERMINES THAT THEWORK WILL REQUIRE DISTURBING THE EXISTINGWALL FINISH IN AREAS OTHER THAN THOSE AREASWHERE SELECTIVE ABATEMENT HAS BEENPERFORMED, HE SHALL CEASE THE WORK IN THATAREA AND CONTACT THE ARCHITECT AND THEOWNER.

2. NO DEMOLITION WORK SHALL START UNTIL ALL THE OWNER'S TELECOM/DATAEQUIPMENT HAS BEEN PROTECTED AS INDICATED ON THE CONSTRUCTIONDRAWINGS.

3. NO DEMOLITION WORK SHALL START UNTIL THE GENERAL CONTRACTOR, THEOWNER AND THE ARCHITECT HAS REVIEWED THE WORK AND IDENTIFIEDCONDITIONS.

4. PHOTOS OF EXISTING CONDITIONS ARE PROVIDED AND INCLUDED IN THE BACKOF THE PROJECT MANUAL FOR THE GENERAL CONTRACTOR'S REFERENCE ANDINFORMATION. THE PHOTOS ARE NUMBERED AND REFERENCED ON THEATTACHED PHOTOGRAPH REFERENCE FLOOR PLAN.

5. DEMOLITION WORK IS SPECIFIC AND SENSITIVE IN NATURE. GENERALCONTRACTOR SHALL BE DILIGENT AND CAUTIOUS DURING THE DEMOLITIONPROCESS. ANY WORK PERFORMED IN THE DEMARC ROOM MUST BEPERSONALLY SUPERVISED AND/OR PERFORMED BY/OR WITH THE SUPERVISIONOF THE GENERAL CONTRACTOR'S APPROVED SUPERINTENDENT PRESENT.

6. ANY EXISTING EXPOSED WOOD FRAMING, BLOCKING, SUPPORT LEDGERS, ETC.REMAINING AND SECURED DIRECTLY TO THE EXISTING CMU WALLS SHALLREMAIN AND BE PAINTED WITH INTUMESCENT FIR PROOFING.

7. ANY ELECTRICAL CONDUIT, DATA WIRING, TELEPHONE OR DATA BOXES, ETC.THAT IS MOUNTED OR SUPPORTED BY ANY WALLS OR CEILING/DECKSTRUCTURAL MEMBERS SCHEDULED TO BE DEMOLISHED SHALL BE SUPPORTEDON A TEMPORARY BASIS UNTIL A PERMANENT MEANS OF SUPPORT CAN BEPROVIDED AND INSTALLED. ANY TEMPORARY SUPPORT OR REMOUNTING OFANY EXISTING TELECOM OR DATA WIRING OR DEVICES SHALL BE REVIEWED ANDDISCUSSED WITH THE OWNER'S REPRESENTATIVE BEFORE ANY WORK ISSTARTED.

NOTE: REFER TO SECTION 01 2100 ALLOWANCES AND 08 70 00 DOOR HARDWARE IN PROJECT MANUAL FOR DOOR HARDWARE ALLOWANCES, DOOR HARDWAREALLOWANCE TO PROVIDE FOR NEW DOOR #101 AND UP-GRADING DOOR HARDWARE ON EXISTING OVERSIZED ENTRANCE DOORS.

AutoCAD SHX Text
8/23/16
CAD-31
Sticky Note
Unmarked set by CAD-31
Page 5: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min
CAD-31
Text Box
CAD-31
Sticky Note
Unmarked set by CAD-31
Page 6: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

D

98

DEMOLITION FLOOR PLAN - GROUND FLOOR - MECHANICALSCALE: 3/8" = 1'-0"

1

1 1

1

1

1

TT

5

RELOCATE BLOWER-COILUNIT. RE: SHT. M-301.

DEMOLITION FLOOR PLAN - MEZZANINE FLOOR - MECHANICALSCALE: 3/8" = 1'-0"

2

98

3

4

3

4

66

6

2

2

2

7

GENERAL NOTES :A. CONTRACTOR SHALL VERIFY EXACT EXTENT AND LOCATION OF ALL ITEMS AFFECTED BY DEMOLITION

WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE AFFECTEDWORK. CAP ALL REMAINING DUCTWORK AND PIPING TO MATCH EXISTING CONDITIONS AS REQUIRED.

NOTES INDICATED BY " " :1. REMOVE DIFFUSER AND ASSOCIATED BRANCH DUCT.

2. REMOVE BLOWER-COILS, DUCTWORK, AND ALL PIPING ASSOCIATED WITH THE SPLIT SYSTEMS ONMEZZANINE LEVEL.

3. EXISTING SUPPLY AIR DUCT TO REMAIN.

4. REMOVE EXISTING EXHAUST AIR DUCT.

5. REMOVE THERMOSTAT.

6. REMOVE SUPPLY AIR DUCT. RE: TO ARCHITECTURAL DRAWINGS FOR PATCHING OF WALL.

7. REMOVE EXISTING AIR TERMINAL BOX AND BRANCH DUCTS BACK TO MAIN. CAP TRUNK DUCTS TOMATCH EXISTING. REMOVE DOWNSTREAM SUPPLY AIR DUCTWORK AS SHOWN.

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

M-201SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

Page 7: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

D

98

FLOOR PLAN - GROUND FLOOR - MECHANICALSCALE: 3/8" = 1'-0"

1

VESTIBULE

24x12 (HIGH & LOW)

MOUNT TOP OF TOP DUCTAT 11'-0" A.F.F. BOTTOMDUCT TO BE MOUNTEDDIRECTLY UNDERNEATH.

2@12X6/S-1250 CFM EA.

2@12X6/S-1250 CFM EA.

2@24X12/S-11000 CFM EA.

2@12X6/S-1250 CFM EA.

2@12X6/S-1250 CFM EA.

EXISTING BLOWER-COILSHOWN RELOCATED.

T

T

BC #16-1(STAND-BY)

32X18/R-1

32X18/R-1

MOUNT BLOWER COILS ON 24" HIGH PLATFORM.PROVIDE SEPARATE PLATFORM FOR EACH UNIT.RELOCATED

THERMOSTAT

GENERAL NOTES :A. CONTRACTOR SHALL VERIFY EXACT SIZE AND LOCATION OF ALL ITEMS AFFECTED BY NEW RENOVATION

WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE AFFECTEDWORK.

M-301

NOTES:

MARK

1. ALL SELECTIONS BASED ON JOBSITE ELEVATION.

CU #16-1 4TTA3060D413.25

SEER

BC #16-1

SERVES CAPACITY - MBH

55.7

ELECTRICAL DATA

460 V, 3Ø, 60 HZ

EXAMPLE: TRANE

CONDENSING UNIT SCHEDULE

2. AMBIENT TEMPERATURE IS 95°F.

4. COOLING EAT IS COIL ENTERING AIR DB/WB TEMPERATURE IN °F.

3. SENSIBLE AND TOTAL CAPACITIES ARE EXPRESSED IN MBTUH.2. COOLING COIL VELOCITY SHALL BE 500 FPM OR LESS.1. ALL SELECTIONS BASED ON JOBSITE ELEVATION.

NOTES:3/40.402000BC #16-1HPESPS.A. CFM

MARK FAN DATA EXAMPLE: TRANEEAT75/6355.7

TOTAL42.2

SENSIBLECOOLING DATA

---O.A. CFM

BLOWER COIL UNIT SCHEDULE

5. UNIT SHALL BE FURNISHED AND INSTALLED WITH THERMOSTAT.

TEM6A0D60H51SA208 V, 1Ø, 60 HZ

ELECTRICAL DATA

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

1. OBD = OPPOSED BLADE DAMPER

3. PF = PLASTER FRAME4. TB = LAY-IN T-BAR5. VERIFY FRAME TYPE WITH CEILING INSTALLER'S LAYOUT.

2. EXT = EXTRACTOR

NOTES:

R-1

MARK

S-1TITUS 350RLRETURN PLENUM PF WHITETITUS 300RL, OBD, EXT

EXAMPLE:

SUPPLY

TYPE LOCATION

DUCT

FRAME

---

FINISH

WHITE

AIR DISTRIBUTION SCHEDULE

MECHANICAL LEGEND

T

POSITIVE PRESSURE P-TRAP

H = 1/2" + FAN MAXIMUM

PRESSURE IN IN. WC. TOTAL STATIC

K = 1/2" MINIMUM

2" 20,001 - 68,000

1-1/2" 12,001 - 20,000

1-1/4" 2,001 - 12,000

1" 801 - 2,000

0 - 8003/4"

HVAC EQUIP.TOTAL CFM

DRAIN SIZE

TEE WITH PLUGFOR CLEANOUT

UNION

FROM DRAINPAN

TO FD K

H

NOTE: CONDENSATE DRAIN SHALL NOT BE SMALLER THAN UNIT CONNECTION.

CONDENSATE DRAIN DETAILNO SCALE

Page 8: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

D

98

FLOOR PLAN - MECHANICAL PIPINGSCALE: 3/16" = 1'-0"

1

VESTIBULE

CONDENSING UNIT CUMB 1204 #2(SERVES DEMARC FIRST FLOOR)

CONDENSING UNIT CUMB 2280 #1(SERVES DATA CENTER)

EXISTING CONDENSING UNITCUMB 2280 #2 (SERVES DATA

CENTER)

EX. BLOWER COIL SHOWNRELOCATED. RECONNECTREFRIGERANT LINES.

BC #16-1

CONNECT NEW CONDENSATE DRAINFROM EXISTING BLOWER COIL TO EXISTINGCONDENSATE DRAIN. MATCH EX. SIZE.SEAL PENETRATION OF RATED WALL.1"

EXTEND DRAIN LINE TONEAREST FLOOR DRAIN ANDTERMINATE WITH 1" AIR GAP.

EXISTING CONDENSING UNITSSERVING DEMOLISHED BLOWERCOILS ON SECOND FLOOR TO BEREMOVED. VERIFY EXACT LOCATIONOF UNITS AT JOB SITE.

CU #16-1

ROUTE REFRIGERANT LINES IN THE MOSTDIRECT MANNER POSSIBLE. COORDINATEWITH MANUFACTURER FOR CORRECTSIZE AND ROUTING REQUIREMENTS FORTHE TOTAL LENGTH AND HEIGHT REQUIRED.

GENERAL NOTES :A. CONTRACTOR SHALL VERIFY EXACT SIZE AND LOCATION OF ALL ITEMS AFFECTED BY DEMOLITION AND

NEW WORK AT THE JOB SITE. REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDINGWITH THE AFFECTED WORK.

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

M-401

Page 9: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

DEMOLITION FLOOR PLAN - MEZZANINE FLOOR - PLUMBINGSCALE: 3/8" = 1'-0"

1

98

CAP

ABANDON CW& HW PIPING

REMOVE CW &HW PIPING

REMOVE CW, HW, &HWR PIPING SHOWNDASHED

REMOVE HW PIPE

REMOVE CW& HW PIPING

EX. 1-1/2" CW, 1" HW,& 3/4" HWR PIPING

TO REMAIN

EX. 1/2" HW LINEDN. IN CHASE

TO REMAIN.

GENERAL NOTES :A. CONTRACTOR TO VERIFY EXACT SIZE AND LOCATION OF ALL ITEMS AFFECTED BY DEMOLITION WORK AT

JOB SITE. REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE AFFECTEDWORK.

98

FLOOR PLAN - MEZZANINE FLOOR - PLUMBINGSCALE: 3/8" = 1'-0"

2

VESTIBULE

ABANDON CW& HW PIPING

EX. 1-1/2" CW, 1" HW,& 3/4" HWR PIPING

TO REMAIN

RECONNECT TO EX.1/2" HW LINE IN CHASE.

3/4"1"

1-1/2"

1-1/2"

3/4"

RECONNECT TOEX. 1-1/2" CW LINE

RECONNECT TOEX. 3/4" HW LINE

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

P-201

PLUMBING LEGEND

Page 10: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

CIRCUIT RUN TO PANELBOARD

ELECTRICAL SYMBOL SCHEDULESYMBOL DESCRIPTION

F CEILING MOUNTED FIRE ALARM HORN STROBE(XX = CANDELA INDICATED; YY = DESIGN dB LEVEL TO BE ACHIEVED)

FLUORESCENT LIGHT FIXTURE TO BE REMOVED

WALL SWITCH TO BE REMOVEDS R

XX YYC

DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W, GROUNDING

ALED LIGHT FIXTURE - TYPE NOTED

AELED LIGHT FIXTURE WITH BATTERY BACKUP - TYPE NOTED

JUNCTION BOX J

DISCONNECT SWITCH

PUSH BUTTON

F WALL MOUNTED FIRE ALARM HORN STROBE(XX = CANDELA INDICATED; YY = DESIGN dB LEVEL TO BE ACHIEVED)XX YY

EXISTING DUPLEX RECEPTACLE TO REMAINE

POWER CIRCUITRY

SWITCH LEG

SD CEILING MOUNTED SMOKE DETECTOR

EXISTING WALL SWITCH TO REMAINS E

PUSH BUTTONE

DISCONNECT SWITCH TO BE REMOVED A. WHERE ELECTRICAL DEVICE IS NOTED TO BE REMOVED, REMOVE ALLUNUSED WIRE AND CONDUIT. REMOVE TO EITHER AN ACTIVEJUNCTION BOX OR FEEDING PANEL. PROVIDE BLANK COVER FORJUNCTION BOX. IF REMOVED BACK TO FEEDING PANEL, RE-LABEL AS"SPARE."

B. WHERE EXISTING ELECTRICAL CIRCUIT FROM FEEDING PANEL ISDEMOLISHED AND REUSED FOR A NEW CIRCUIT, RE-LABEL BREAKERDIRECTORY. FURNISH AND INSTALL NEW CIRCUIT BREAKER.

C. UNIVERSITY OF TEXAS FIRE SAFETY SYSTEMS SHOP SHALLSUPERVISE THE FINAL CONNECTION TO EXISTING FIRE ALARMSYSTEM. CONNECT FIRE ALARM A/V APPLIANCES TO A DISTRIBUTEDPOWER SUPPLY (TO BE PROVIDED AS PART OF THIS PROJECT).CONTRACTOR SHALL VERIFY ADEQUACY OF EXISTING POWERSUPPLY AND SHALL PROVIDE NEW POWER SUPPLY(S) AS REQUIRED.INCLUDE IN THE FIRE ALARM SUBMITTAL CALCULATION DATA TOCONFIRM POWER SUPPLY LOADS. VERIFY LOCATION OF EXISTINGDEVICE AT JOB SITE.

D. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND WIRINGFOR FIRE ALARM SYSTEM.

E. WHERE ELECTRICAL DEVICES ARE CONNECTED TO EXISTINGCIRCUITS CREATED BY DEMOLITION IN THE REMODELED AREA, NOTECIRCUIT NUMBER ON RECORD DRAWINGS AND RE-LABEL CIRCUITBREAKER DIRECTORY.

F. WHERE RECEPTACLES TO BE REMOVED ARE SERVED FROM CONDUITENCASED IN THE CONCRETE FLOOR SLAB, PROVIDE NECESSARYCONDUIT AND WIRE TO REESTABLISH POWER TO REMAINING DEVICESSERVED BY THE CIRCUIT.

G. WHERE NEW WIRING DEVICES ARE TO BE INSTALLED, THEY MAY BEINSTALLED USING EXPOSED CONDUIT AND JUNCTION BOXES WHENLOCATED ON EXISTING CMU OR CONCRETE WALLS. OTHERWISE, ALLCONDUIT SHALL BE CONCEALED AND JUNCTION BOXES SHALL BEFLUSH MOUNTED.

H. ALL VOICE/DATA CABLING WILL BE INSTALLED IN A SEPARATECONTRACT. EXTEND 1 1/4" CONDUIT FROM ALL VOICE/DATA OUTLETSAND RACEWAY TO ABOVE THE CEILING IN SPACES WITH CEILING ORTO THE STRUCTURE ABOVE IN AREAS WITHOUT CEILINGS. INSTALL4"X4" JUNCTION BOX WITH SINGLE GANG PLASTER RING WHEREMOUNTED IN GYP WALLS.

I. IN GENERAL, UNLESS NOTED OTHERWISE, REMOVE ALL DEVICES,CONDUIT, AND WIRE IN THE ROOM AND BELOW THE FLOOR. NOUNUSED MATERIAL SHALL REMAIN. VERIFY SCOPE OF WORK ATJOBSITE.

J. RE-BALANCE, AS NEEDED, POWER DISTRIBUTION TO ASSURE THATEXISTING AND NEW CIRCUITS SERVING ALL EQUIPMENT IN THE AREAOF WORK FOR THIS PROJECT WILL NOT BE OVERLOADED.

K. AFTER THE DEMOLITION PHASE OF THE PROJECT, AND PRIOR TO THEBEGINNING OF THE NEW WORK, THE CONTRACTOR SHALL RECORDTHE AMPERE LOAD ON EACH LEG OF PANEL(S), FOR (7) CONSECUTIVEDAYS. THE RESULTING READINGS SHALL THEN BE SUBMITTED TO THEUT PROJECT MANAGER OF RECORD FOR REVIEW. THE CONTRACTORSHALL AVOID INSTALLING ANY NEW CONDUITS OR CONDUCTORSUNTIL THESE READINGS HAVE BEEN REVIEWED AND A NOTICE TOPROCEED HAS BEEN GIVEN BY THE UT PROJECT MANAGER.

L. PER UT STANDARDS, REFER TO THE UT DESIGN AND CONSTRUCTIONSTANDARDS FOR FIRE ALARM REQUIRING NOTIFICATION APPLIANCESTO EITHER BE BLANK OR BE MARKED WITH THE WORD "ALERT". THEWORD "FIRE" SHALL NOT APPEAR ON NOTIFICATION APPLIANCES.THIS APPLIES TO NEW DEVICES AS WELL AS ANY EXISTING DEVICESTHAT ARE DEMOLISHED TO BE RELOCATED OR REPLACED.

M. FIRE ALARM CONTRACTOR SHALL MEET THE REQUIREMENTS OF NFPA72, THE NATIONAL FIRE ALARM AND SIGNALING CODE AND THE UTDESIGN AND CONSTRUCTION STANDARD - SECTION 28 31 00 - FIREALARM AND SIGNALING (REVISED JANUARY 2013).

GENERAL NOTES:

1. NUMBERED WORK AREAS AT A NEGATIVE PRESSURE RELATIVE TOTHE REMAINDER OF THE BUILDING. COVER ALL OPENINGS INTO THEBUILDING. ALERT THE OWNER TO THE POSSIBILITY OF DUST FROMDEMOLITION / CONSTRUCTION ACTIVITIES AT LEAST 24 HOURS INADVANCE OF SUCH OPERATIONS, IN WRITING.

2. CONTRACTOR SHALL COORDINATE WITH EXISTING SYSTEMS WHICHSHALL REMAIN IN OPERATION DURING DEMOLITION ANDCONSTRUCTION PHASES AND COORDINATE WITH OTHER TRADES(HVAC, PLUMBING, ETC.) TO RELOCATE OR REROUTE EXISTINGCONDUITS, ETC. AS NECESSARY TO ACCOMMODATE THE NEW WORKAND PROVIDE A COMPLETE WORKING SYSTEM.

ELECTRICAL DEMOLITION NOTES:

1. SIZE AND APPROXIMATE LOCATION OF NEW OPENINGS SHALL BESHOWN ON CONTRACTOR'S SHOP DRAWINGS. LOCATE COREDOPENINGS SO THAT EXISTING REINFORCING OR CONDUIT WILL NOTBE CUT DURING THE CORING PROCESS.

2. PRIOR TO CORING OR DRILLING PILOT HOLES, LOCATE EXISTINGREINFORCING AND/OR CONDUIT USING FERROSCAN OR EQUIVALENTELECTRONIC DEVICE. FERROSCAN OPERATOR SHALL MARKLOCATION OF EXISTING REINFORCING AND/OR CONDUIT ONCONCRETE WALLS/CEILINGS. VERIFY WITH TESTING LAB THAT THEELECTRONIC SCANNING DEVICE IS SUITABLE FOR THE THICKNESS OFCONCRETE BEING SCANNED. FERROSCAN IS GOOD FOR CONCRETEUP TO 6"Ф THICK, SO CONCRETE OVER 6"Ф THICK WILL NEED TOBE SCANNED FROM BOTH SIDES.

3. PRIOR TO CORING, FIELD VERIFY, BY OBSERVING WALLS (ANDCEILINGS) FROM THE OTHER SIDE, THAT NEW OPENING WILLNOT CUT EXISTING REINFORCING AND/OR CONDUIT BY DRILLING1/4" DIAMETER PILOT HOLES.

4. SUPPORT REMOVED MATERIAL FROM BELOW. PROTECT AREASBELOW FROM DUST, DEBRIS, AND WATER. PROVIDE FORCOLLECTION AND DISPOSAL OF WATER USED IN CORINGOPERATIONS.

5. WHEN THE CORING LOCATION IS LINED UP WITH THE EXISTINGREINFORCING OR ELECTRICAL SWITCH BOX, RELOCATE THECORING LOCATION.

CONSTRUCTION NOTES:

WIRING DEVICE MOUNTING HEIGHTS - TYPICALNO SCALE

1'-0" BELOWFINISHED CLG.(MOUNT 8'-0" AFF

SLOPED CLG.CONDITION)

FIRE ALARMPULL STATION

THERMOSTAT,

FOR NO CEILING ORCLOCK HANGER OUTLET

RECEPTACLE

TELEPHONE OUTLET

DATA TERMINAL OUTLET

NOTE: VERIFY ALL HEIGHTS WITH ARCHITECT

1'-6

"A

FF

WALL SWITCH

4'-0

" AFF

DIMMER SWITCH

FINISHED CEILING

FINISHED FLOOR

LENS SHOULDBE INSTALLEDBETWEEN 80"AND 96" AFF OR,IN LOW CEILINGAREAS, 6"BELOW CEILING.

FIRE ALARM HORN/LIGHT

5

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

E-101

Page 11: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

D

98

DEMOLITION FLOOR PLAN - GROUND FLOOR - ELECTRICALSCALE: 3/8" = 1'-0"

1

REMOVE LIGHT FIXTURES

SALVAGE CIRCUIT FOR EXISTINGBLOWER COIL.

REMOVE LIGHT FIXTUREREMOVE LIGHT FIXTURES

EXISTING ELECTRICAL PANEL TOREMAIN. REFER TO KEYED NOTE 6ON SHEET A-301 FOR WORKRELATED TO PANEL DURINGDEMOLITION.

R

REMOVE SWITCH

EE

E

EXISTING EMERGENCY PUSH BUTTONAND SWITCHES TO REMAIN

E

EXISTING CONDUIT TO REMAIN

DEMOLITION FLOOR PLAN - MEZZANINE FLOOR - ELECTRICALSCALE: 3/8" = 1'-0"

2

D

98

REMOVE LIGHT FIXTURES

REMOVE LIGHT FIXTURES

REMOVE DISCONNECT SWITCH SERVINGBLOWER COILS AND ALL ASSOCIATED WIREAND CONDUIT.

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

E-201

Page 12: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

GENERAL NOTES :A. INSTALL ALL WIRING AND CONDUIT REQUIRED FOR A COMPLETE AND FUNCTIONING CLEAN-AGENT

FIRE-EXTINGUISHING SYSTEM. COORDINATE ALL WORK WITH CLEAN-AGENT FIRE-EXTINGUISHINGSYSTEM CONTRACTOR.

NOTES INDICATED BY " " :1. EXTEND 2-#12 AND #12 GR. IN 1/2" C. TO SPARE 20A/1P CIRCUIT BREAKER IN PANEL 'ESL.'

2. EXTEND 2-#12 AND #12 GR. IN 1/2" C. TO EXISTING LIGHTING CIRCUIT CREATED BY DEMOLITION IN THISROOM.

3. CONDUIT SHALL PENETRATE THRU STORE-FRONT MULLION.

4. REPLACE SPST SWITCH WITH RED SWITCH.

FLOOR PLAN - LIGHTINGSCALE: 3/16" = 1'-0"

1

VESTIBULE

AE

E

A AE

A A

A

A

AE

AAE

A

EXISTING EMERGENCYPANEL 'ESL'

EXISTING EMERGENCYPANEL 'HIT'

1

2

E

4

3

MECHANICAL ROOM

SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16

E-301

Page 13: INTERIOR RENOVATION · 2020. 7. 29. · fhc fin flr fo fr frtw ft fv ga galv gbf gbp gc gut gyp. gwb h/c hdw hgt, ht hm horiz hr hwy ibc in insul jst jt lav mb max mech mfr min

GENERAL NOTES :A. INSTALL ALL WIRING AND CONDUIT REQUIRED FOR A COMPLETE AND FUNCTIONING CLEAN-AGENT

FIRE-EXTINGUISHING SYSTEM. COORDINATE ALL WORK WITH CLEAN-AGENT FIRE-EXTINGUISHINGSYSTEM CONTRACTOR.

NOTES INDICATED BY " " :1. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM CONTROL PANEL.

2. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM SMOKE DETECTOR.

3. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM MANUAL RELEASE PUSHBUTTON.

4. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM ABORT SWITCH.

5. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM A/V ALARM.

6. CLEAN-AGENT FIRE-EXTINGUISHING SYSTEM STORAGE CONTAINERS.

7. EXTEND NAC CIRCUIT TO BUILDING FIRE ALARM SYSTEM.

VESTIBULE

E

E EXISTING RECEPTACLESERVING BLOWER COIL

FLOOR PLAN - POWER / SPECIAL SYSTEMSSCALE: 3/16" = 1'-0"

1

EXISTING EMERGENCYPANEL 'ESL'

EXISTING EMERGENCYPANEL 'HIT'

MECHANICAL ROOM

BC #16-1

CU #16-1

EXTEND 4-#12 AND #12 GR. IN 1/2"C.TO NEW 15A/3P CIRCUIT BREAKER INPANEL 'HIT.' INSTALL CIRCUIT BREAKERIN AN AVAILABLE SPACE.

EXTEND 2-#12 AND #12 GR. IN 1/2"C.TO SPARE 20A/2P CIRCUIT BREAKERIN PANEL 'ESL.'

6

J

EXTEND 2-#12 AND #12 GR. IN 1/2"C.TO SPARE 20A/1P CIRCUIT BREAKERIN PANEL 'ESL.'

1

SD SD

2

3

48"F

5

FC

7 48"

4

F 5

E-401SHEET:

312 N

. BIG

SPR

ING

SUIT

E 10

0 (4

32)6

87-0

781

MIDL

AND,

TEX

AS

A R

C H

I T

E C

T S

P C

REVISION

NO. DATE: DESCRIPTION:

Proje

ct: 03

615

4901

E U

NIVE

RSIT

Y BL

VDOD

ESSA

, TEX

AS 79

762

DATE

: 08/1

1/201

6

UNIV

ERSI

TY o

f TEX

AS o

f the

PER

MIAN

BAS

INUT

PB M

ESA

BUILD

ING

DEMA

RC R

OOM

INTE

RIOR

REN

OVAT

ION

AAI PROJ. NO. 2212026

TBPE FIRM #1005

08/23/16