interface solution line card - miinet.com

2
www.miinet.com Demand Moore Reliability Demand Moore Reliability www.miinet.com Interface Solution Line Card Pneumatic I/P and P/I Converters Analog, Smart HART ® , FOUNDATION Fieldbus and PROFIBUS Temperature Transmitters RTD Thermocouple Ohm Millivolt Monitoring or Control System Current, Voltage, RTD, Thermocouple, Resistance, Potentiometer, Discrete and Relay I/O HTTP - Web Server MODBUS/TCP MODBUS RTU MODBUS Master * All product names are trademarks of their respective companies. * HART is a registered trademark of the FieldComm Group. Signal Transmitters, Isolators, Converters and Splitters 4-20mA HART ® Fieldbus PROFIBUS Process Control and Distributed I/O Networks Current/Voltage 4-20mA with HART ® Frequency MODBUS/TCP HART-IP MODBUS RTU 4-20mA Relays Process Controllers, Monitors and Backup Stations Smart HART ® Multivariable Transmitters and Smart Valves Smart HART ® Loop Monitors and Gateways MooreHawke Fieldbus Device Couplers and Power Supplies FOUNDATION fieldbus™ PROFIBUS PA Indicators and Displays Current, Voltage, RTD, Thermocouple Relay 4-20mA 4-20mA with HART ® Analog Output or Relay 4-20mA Relay Functional Safety - IEC 61508/61511 Safety Instrumented Systems (SIS) 4-20mA 4-20mA with HART Relay Alarm Trips Current, Voltage, RTD, Thermocouple, HART ® (Safe Area or Associated Intrinsically-Safe Inputs)

Upload: others

Post on 25-Feb-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Interface Solution Line Card - miinet.com

w w w . m i i n e t . c o m • Demand Moore Reliability Demand Moore Reliability • w w w . m i i n e t . c o m

Interface Solution Line Card

Pneumatic

I/P and P/I Converters

Analog, Smart HART ®, FOUNDATION Fieldbus™

and PROFIBUS Temperature Transmitters

RTD Thermocouple

OhmMillivolt

Monitoring or Control SystemCurrent, Voltage, RTD, Thermocouple,

Resistance, Potentiometer,Discrete and Relay I/O

HTTP - Web ServerMODBUS/TCPMODBUS RTU

MODBUS Master

* All product names are trademarks of their respective companies.* HART is a registered trademark of the FieldComm Group.

Signal Transmitters, Isolators, Converters

and Splitters

4-20mAHART®

FieldbusPROFIBUS

Process Control andDistributed I/O Networks

Current/Voltage4-20mA with HART®

Frequency

MODBUS/TCPHART-IP

MODBUS RTU4-20mA Relays

Process Controllers,Monitors and Backup Stations

Smart HART® Multivariable Transmitters and Smart Valves

Smart HART ® Loop Monitors and Gateways

MooreHawkeFieldbus Device Couplers

and Power Supplies

FOUNDATION fieldbus™PROFIBUS PA

Indicators and Displays

Current, Voltage,

RTD, Thermocouple

Relay

4-20mA4-20mA with HART®

Analog Output or Relay

4-20mA

Relay

Functional Safety - IEC 61508/61511

Safety InstrumentedSystems (SIS)

4-20mA4-20mA with HART

Relay

Alarm Trips

Current, Voltage, RTD, Thermocouple, HART®

(Safe Area or AssociatedIntrinsically-Safe Inputs)

Page 2: Interface Solution Line Card - miinet.com

Demand Moore Reliability • w w w . m i i n e t . c o mw w w . m i i n e t . c o m • Demand Moore Reliability ©2019 Moore Industries-International, Inc. May 2019

Interface Solution Line Card Visit the Moore Industries Website and Online Catalog at www.miinet.com

United States • [email protected]: (818) 894-7111 • FAX: (818) 891-2816

Australia • [email protected]: (02) 8536-7200 • FAX: (02) 9525-7296

Belgium • [email protected]: 03/448.10.18 • FAX: 03/440.17.97The Netherlands • [email protected]

Tel: (0)344-617971 • FAX: (0)344-615920

China • [email protected]: 86-21-62491499 • FAX: 86-21-62490635

United Kingdom • [email protected]: 01293 514488 • FAX: 01293 536852

When you need to interface field processes with computer-based systems, readout equipment, and other instrumentation... our technology, services and exper-tise help you do it efficiently, safely and cost-effectively.

AC Power Transducers and MonitorsSchedule maintenance, identifyinefficiencies, cut energy use andprevent expensive damage to aload device by accuratelymonitoring AC power use.

Fieldbus Device Couplers and Power SuppliesDeliver a fast and easy way to connect, protect, power and terminate multiple fieldbus devices in FOUNDATION™ Fieldbus and PROFIBUS PA segments.

Process Control and Distributed I/O NetworksEliminate expensive point-to-pointwires by sending just a few–or thousands of–process monitoring and control signals between thefield and control room on one digitalcommunication link.

Signal Transmitters, Isolators and ConvertersConvert, isolate, split, boost andstep down process signals so fieldinstruments can interface directlywith indicators, recorders, DCS,PLC and SCADA systems.

I/P and P/I ConvertersConvert a current signal to apneumatic signal so a DCS or PLC can control a valve or actuator; or convert pneumatic signals to current signals so remote pneumatic devices can interface with electronicinstruments and computer-basedmonitoring systems.

Indicators and DisplaysTake a process input signal from atransmitter loop and view real-timeprocess status in rugged andhazardous field environments.

Limit Alarm Trips and SwitchesProvide on/off control, warn oftrouble, or provide emergency shut-down by sending one or more alarm(relay) outputs when a monitoredprocess signal falls outside of aselected high and/or low limit.

Functional Safety - IEC 61508 Monitor, alarm or shutdown critical and hazardous processes, measure critical temperatures, isolate a Safety Instrumented System (SIS) loop while passing HART data, or split critical signals while passing HART data.

The latest innovations in monitoring and control interface solutions are just a click away.

Everything you need to find signal interface instruments fast!The Moore Industries website provides industry applications, news, technical papers, and product information with easy to navigate menus that allow you to find what you need quickly and efficiently. Explore our online product catalog where you will find useful information and downloads for each of our products. Visit www.miinet.com now.

���������������������������� ���� ������� ���

Temperature Sensors, Transmitters and AssembliesTake a weak, low-level RTD orthermocouple signal and convert itto a high-level analog signal moresuitable for long-distance transmission through a noisy plant,and ready for direct interface withan indicator, recorder, PLC, DCSor SCADA system.

Convert HART process variables and diagnostic data from smart multivariable transmitters and valves to MODBUS/TCP, HART-IP, MODBUS RTU, analog and discrete signals to prevent costly false shutdowns; and warn of unwanted process or instrument fault conditions.

Process Controllers, Monitors and Backup StationsPrecisely control and monitor atemperature, pressure, level or flowprocess variable in batch andcontinuous processes, or back upcritical or safety-related loopscontrolled by PLC, DCS and other control systems.

Smart HART® Loop Monitors, Interfaces and Gateways