intent to issue air emission permit to ardent mills llc, lake city · 2019-10-10 · tfac 1: ardent...

109
DRAFT Air Individual Permit State Permit 15700034101 Permittee: Ardent Mills LLC Facility name: Ardent Mills LLC Lake City Plant 905 W Marion St Lake City, MN 550412007 Wabasha County Expiration date: Nonexpiring Permit * All Title I Conditions do not expire State Permit: < > Permit characteristics: State; Limits to avoid Part 70/ Limits to avoid NSR; Limits to avoid NSR The emission units, control equipment and emission stacks at the stationary source authorized in this permit issuance are as described in the submittals listed in the Permit Applications Table. This permit issuance authorizes the Permittee to operate the stationary source at the address listed above unless otherwise noted in the permit. The Permittee must comply with all the conditions of the permit. Any changes or modifications to the stationary source must be performed in compliance with Minn. R. 7007.1150 to 7007.1500. Terms used in the permit are as defined in the state air pollution control rules unless the term is explicitly defined in the permit. Unless otherwise indicated, all the Minnesota rules cited as the origin of the permit terms are incorporated into the SIP under 40 CFR § 52.1220 and as such are enforceable by U.S. Environmental Protection Agency (EPA) Administrator or citizens under the Clean Air Act. Signature: [ ] This document has been electronically signed. for the Minnesota Pollution Control Agency for Don Smith, P.E., Manager Air Quality Permits Section Industrial Division

Upload: others

Post on 05-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

 

   

DRAFT Air Individual Permit State Permit 15700034‐101 

 Permittee:  Ardent Mills LLC 

Facility name:  Ardent Mills LLC ‐ Lake City Plant 905 W Marion St Lake City, MN 55041‐2007 Wabasha County 

 Expiration date:  Non‐expiring Permit * All Title I Conditions do not expire  State Permit:  <     >  Permit characteristics:  State; Limits to avoid Part 70/ Limits to avoid NSR; Limits to avoid NSR  The emission units, control equipment and emission stacks at the stationary source authorized in this permit issuance are as described in the submittals listed in the Permit Applications Table.  This permit issuance authorizes the Permittee to operate the stationary source at the address listed above unless otherwise noted in the permit. The Permittee must comply with all the conditions of the permit. Any changes or modifications to the stationary source must be performed in compliance with Minn. R. 7007.1150 to 7007.1500. Terms used in the permit are as defined in the state air pollution control rules unless the term is explicitly defined in the permit.  Unless otherwise indicated, all the Minnesota rules cited as the origin of the permit terms are incorporated into the  SIP under 40 CFR § 52.1220 and as such are enforceable by U.S. Environmental Protection Agency (EPA) Administrator  or citizens under the Clean Air Act.  

Signature:  [ ]   This document has been electronically signed.  for the Minnesota Pollution Control Agency 

for  Don Smith, P.E., Manager    Air Quality Permits Section    Industrial Division 

    

Page 2: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Table of Contents  

  Page  

1.  Permit applications table ............................................................................................................................................. 3 2.  Where to send submittals ............................................................................................................................................ 4 3.  Facility description ....................................................................................................................................................... 5 4.  Summary of subject items ........................................................................................................................................... 6 5.  Limits and other requirements .................................................................................................................................. 34 6.  Submittal/action requirements ................................................................................................................................. 98 7.  Appendices ............................................................................................................................................................... 107 

Appendix A. Insignificant activities and general applicable requirements ............................................................ 107 Appendix B. Alternative Test Method for Opacity Determination of Emissions from Intermittent Dust‐Generating 

Operations (alternative to Method 9). ............................................................................................................ 107 

Page 3: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit issued:  [month day, year]  15700034‐101 Permit expires:  [month day, year]  Page 3 of 109   

 

1. Permit applications table  

Subsequent permit applications: Title description  Application receipt date  Action number State Individual Permit application 

04/27/2018  15700034‐101 

Final certified application   10/7/2019  15700034‐101     

Page 4: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit issued:  [month day, year]  15700034‐101 Permit expires:  [month day, year]  Page 4 of 109   

 

2. Where to send submittals   

Send submittals that are required to be submitted to the EPA regional office to:  Chief Air Enforcement Air and Radiation Branch EPA Region V 77 West Jackson Boulevard Chicago, Illinois 60604 

 Each submittal must be postmarked or received by the date specified in the applicable Table. Those submittals required by Minn. R. 7007.0100 to 7007.1850 must be certified by a responsible official, defined in Minn. R. 7007.0100, subp. 21. Other submittals shall be certified as appropriate if certification is required by an applicable rule or permit condition. 

 Send submittals that are required by the Acid Rain Program to: 

 U.S. Environmental Protection Agency Clean Air Markets Division 1200 Pennsylvania Avenue NW (6204N) Washington, D.C. 20460 

 Send any application for a permit or permit amendment to: 

 Fiscal Services – 6th Floor Minnesota Pollution Control Agency 520 Lafayette Road North St. Paul, Minnesota 55155‐4194 

 Also, where required by an applicable rule or permit condition, send to the Permit Document Coordinator notices of: 

 a. Accumulated insignificant activities b. Installation of control equipment c. Replacement of an emissions unit, and d. Changes that contravene a permit term 

 Unless another person is identified in the applicable Table, send all other submittals to:  

AQ Compliance Tracking Coordinator Industrial Division Minnesota Pollution Control Agency 520 Lafayette Road North St. Paul, Minnesota 55155‐4194 

Or  Email a signed and scanned PDF copy to: [email protected] (for submittals related to stack testing) [email protected]  (for other compliance submittals) (See complete email instructions in “Routine Air Report Instructions Letter” at http://www.pca.state.mn.us/nwqh472.) 

   

Page 5: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit issued:  [month day, year]  15700034‐101 Permit expires:  [month day, year]  Page 5 of 109   

 

3. Facility description   

Ardent Mills ‐ Lake City Plant (Facility or Ardent Mills) operates a wheat flour mill and is located at 905 W Marion Street in Lake City, Wabasha County, Minnesota. The facility consists of grain receiving, elevators, grain cleaning, wheat mills, flour blending, storage, packaging, hammermilling, and a boiler. Ardent Mills processes wheat received into flour and middling (midds) for animal feed. Ardent Mills uses phosphine for fumigation.    The main pollutants of concern are particulate matter (PM), particulate matter less than 10 micron (PM10), particulate matter less than 2.5 micron (PM2.5), and hazardous air pollutants (HAP). Ardent Mills uses fabric filter control equipment to reduce emissions of PM, PM10, and PM2.5.    

 

   

Page 6: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit issued:  [month day, year]  15700034‐101 Permit expires:  [month day, year]  Page 6 of 109   

 

 4. Summary of subject items 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

TFAC 1: Ardent Mills LLC 

    

ACTV 4: All IAs      COMG 1: Flour Blending & Truck Loading 

has members  EQUI 287, EQUI 288, EQUI 289, EQUI 290, EQUI 291, EQUI 292, EQUI 293, EQUI 294 

COMG 2: Feed Loadout  has members  EQUI 295, EQUI 296, EQUI 297, EQUI 298, EQUI 299, EQUI 300, EQUI 301, EQUI 302, EQUI 303, EQUI 304 

EQUI 1: Rail and Truck Unload Pit 

sends to  STRU 1: Filter 01 Grain Receiving Stack Vent 

EQUI 2: Rail Receiving Leg 

sends to  STRU 1: Filter 01 Grain Receiving Stack Vent 

EQUI 2: Rail Receiving Leg 

is controlled by 

TREA 1: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 3: Elevator to Mill Wheat Leg 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 3: Elevator to Mill Wheat Leg 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 4: Elevator Unload Scale 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 4: Elevator Unload Scale 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 5: Elevator 4th Floor Clean Up Hole 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 6: North Aspirator 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 6: North Aspirator 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 7: South Aspirator 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 7: South Aspirator 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 8: C‐14 Conveyor  sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 8: C‐14 Conveyor  is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 9: C‐12 Conveyor  sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 9: C‐12 Conveyor  is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 10: C‐15 Conveyor 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 10: C‐15 Conveyor 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 11: C‐16 Conveyor 

sends to  STRU 1: Filter 01 Grain Receiving 

Page 7: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 7 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 11: C‐16 Conveyor 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 12: Elevator 3rd Floor Cyclone 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 12: Elevator 3rd Floor Cyclone 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 13: Elevator 2nd Floor Cleanup Hole 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 14: Elevator Basement Aspiration 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 15: C‐27 Conveyor 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 15: C‐27 Conveyor 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 16: C‐19 Conveyor 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 16: C‐19 Conveyor 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 17: C‐18 Conveyor 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 17: C‐18 Conveyor 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 18: C‐21 Conveyor 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 18: C‐21  is controlled  TREA 2: Fabric 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Conveyor  by  Filter ‐ Low Temp, T<180 Degrees F 

EQUI 19: Mixed Wheat Leg 

sends to  STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

EQUI 19: Mixed Wheat Leg 

is controlled by 

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 20: C‐Mill Surge Bin 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 20: C‐Mill Surge Bin 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 21: C‐Mill Technovator Cyclone 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 21: C‐Mill Technovator Cyclone 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 22: C‐Mill Feed Cyclone 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 22: C‐Mill Feed Cyclone 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 23: C‐Mill Screenings Cyclone 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 23: C‐Mill Screenings Cyclone 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 24: C‐Mill Combi‐Cleaner 

sends to  STRU 3: Filter 06 C‐Mill Cleaning 

Page 8: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 8 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description House Stack Vent 

EQUI 24: C‐Mill Combi‐Cleaner 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 25: C‐MiII WTR Scourer 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 25: C‐MiII WTR Scourer 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 26: C‐Mill Wheat to Roll Scale 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 26: C‐Mill Wheat to Roll Scale 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 27: C‐Mill 1/2 BK Rollstand 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 27: C‐Mill 1/2 BK Rollstand 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 28: C‐Mill Clears Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 28: C‐Mill Clears Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 29: C‐Mill Red Dog Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 29: C‐Mill Red Dog Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 30: B/C Mill Corn Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 30: B/C Mill Corn Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 31: C‐Mill Temp Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 31: C‐Mill Temp Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 32: C‐Mill CH Screenings Scale Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 32: C‐Mill CH Screenings Scale Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 33: C‐Mill Clean Wheat Scale Hopper 

sends to  STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

EQUI 33: C‐Mill Clean Wheat Scale Hopper 

is controlled by 

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 34: Hammer Mills Cyclone 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 34: Hammer Mills Cyclone 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 35: B‐Mill Bran Cyclone 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack 

Page 9: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 9 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Vent 

EQUI 35: B‐Mill Bran Cyclone 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 36: B‐Mill Shorts Cyclone 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 36: B‐Mill Shorts Cyclone 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 37: B‐Mill Screenings Cyclone 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 37: B‐Mill Screenings Cyclone 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 38: B‐Mill Combi‐Cleaner 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 38: B‐Mill Combi‐Cleaner 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 39: Screenings Sifter Feed Conveyor 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 39: Screenings Sifter Feed Conveyor 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 40: B/C Mills Feed Hopper 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 40: B/C Mills Feed Hopper 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 41: B‐Mill Wheat to Temper Hopper 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 41: B‐Mill Wheat to Temper Hopper 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 42: Cleaning House 1st Floor Feed ln 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 43: B‐Mill Cleaning House Dirty Wheat Scale 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 43: B‐Mill Cleaning House Dirty Wheat Scale 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 44: B‐Mill Tecnovator Cyclone 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 44: B‐Mill Tecnovator Cyclone 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 45: B‐Mill Wheat to Mill Hopper 

sends to  STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

EQUI 45: B‐Mill Wheat to Mill Hopper 

is controlled by 

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 46: A‐Mill Wheat to Temper Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 46: A‐Mill Wheat to Temper Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 

Page 10: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 10 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 47: A‐Mill Screenings Conveyor 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 47: A‐Mill Screenings Conveyor 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 48: A‐Mill Feed to Bin Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 48: A‐Mill Feed to Bin Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 49: A‐Mill Wheat to Mill Scale Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 49: A‐Mill Wheat to Mill Scale Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 50: A‐Mill Screenings Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 50: A‐Mill Screenings Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 51: A‐Mill Temper Bin Collection Screw 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 51: A‐Mill Temper Bin Collection Screw 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 52: A‐Mill Wheat to Mill Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 52: A‐Mill Wheat to Mill Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 53: A‐Mill Combi Cleaner 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 53: A‐Mill Combi Cleaner 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 54: A‐Mill Wheat to Surge Bin Aspiration Fan 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 54: A‐Mill Wheat to Surge Bin Aspiration Fan 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 55: A‐Mill Wheat to Surge Bin Scourer 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 55: A‐Mill Wheat to Surge Bin Scourer 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 56: A‐Mill Pre Break L12 Rollstand 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 56: A‐Mill Pre Break L12 Rollstand 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 

Page 11: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 11 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 57: A‐Mill Pre Break 3/4 Rollstand 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 57: A‐Mill Pre Break 3/4 Rollstand 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 58: A‐Mill Pre Break 5/6 Rollstand 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 58: A‐Mill Pre Break 5/6 Rollstand 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 59: Cleaning House 5th Floor Feed‐In Station 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 60: A‐Miil Technovator Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 60: A‐Miil Technovator Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 61: A‐Mill Screenings Cyclone 1 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 61: A‐Mill Screenings Cyclone 1 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 62: A‐Mill Screenings Cyclone 2 

sends to  STRU 5: Filter 27 A‐Mill Cleaning 

SI ID:  Description 

Relationship type 

Related SI ID: Description House & Feed Loadout Stack Vent 

EQUI 62: A‐Mill Screenings Cyclone 2 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 63: A‐Mill Screenings Cyclone 3 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 63: A‐Mill Screenings Cyclone 3 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 64: Elevator Screenings Cyclone 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 64: Elevator Screenings Cyclone 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 65: A‐Mill Wheat Temper Receiving Hopper 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 65: A‐Mill Wheat Temper Receiving Hopper 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 66: A‐Mill P‐13 Cyclone 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 66: A‐Mill P‐13 Cyclone 

is controlled by 

TREA 5: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 67: A‐Mill 40 Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics 

Page 12: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 12 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 67: A‐Mill 40 Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 68: A‐Mill 41 Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 68: A‐Mill 41 Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 69: A‐Mill 42 Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 69: A‐Mill 42 Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 70: Cut Stream 3‐Way Splitter Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 70: Cut Stream 3‐Way Splitter Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 71: A‐MiII 3 BRK 1(3) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 72: A‐MiII 2 BRK 1,2 (4) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 72: A‐MiII 2 BRK 1,2 (4) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 73: A‐MiII 3 BRK 2 (5) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 73: A‐MiII 3 BRK 2 (5) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 74: A‐MiII 4 BRK  sends to  STRU 6: Filter 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

1 (6) Cyclone  11 A‐Mill Pneumatics Stack Vent 

EQUI 74: A‐MiII 4 BRK 1 (6) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 75: A.MiII A,B SIZ (8) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 75: A.MiII A,B SIZ (8) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 76: A‐Mill A,B SIZ (8) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 76: A‐Mill A,B SIZ (8) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 77: A‐Mill C SIZ (9) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 77: A‐Mill C SIZ (9) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 78: A‐Mill SIZ A/B (Split w/ 8) Cylcone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 78: A‐Mill SIZ A/B (Split w/ 8) Cylcone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 79: A‐Mill 1 Midds C (10) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 79: A‐Mill 1 Midds C (10) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 80: A‐Mill 1 Midds B (11) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics 

Page 13: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 13 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 80: A‐Mill 1 Midds B (11) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 81: A‐Mill 1 Mids A (12) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 81: A‐Mill 1 Mids A (12) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 82: A‐Mill 5 Bran F (13) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 82: A‐Mill 5 Bran F (13) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 83: A‐Mill 1,2,3 BC (14) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 83: A‐Mill 1,2,3 BC (14) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 84: A‐Mill 1,2,3 BC (15) Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 84: A‐Mill 1,2,3 BC (15) Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 85: A‐MiII 1 BRK Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 85: A‐MiII 1 BRK Cyclone 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 86: A‐MiII 2 BRK Cyclone 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 86: A‐MiII 2 BRK  is controlled  TREA 6: Fabric 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Cyclone  by  Filter ‐ Low Temp, T<180 Degrees F 

EQUI 87: A 1 MB Rollstand 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 87: A 1 MB Rollstand 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 88: A 1 MA Rollstand 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 88: A 1 MA Rollstand 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 89: A Mill Surge Bin 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 89: A Mill Surge Bin 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 90: A 1 BRK Airlock Hopper 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 90: A 1 BRK Airlock Hopper 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 91: A 2 BRK Airlock Hopper 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 91: A 2 BRK Airlock Hopper 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 92: A Flour to Patent Splitter Airlock Hopper 

sends to  STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

EQUI 92: A Flour to Patent Splitter Airlock Hopper 

is controlled by 

TREA 6: Fabric Filter ‐ Low Temp, T<180 

Page 14: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 14 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 93: Germ Aspirator Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 93: Germ Aspirator Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 94: A‐MiII 5 BRK Sift to BR Dust 1,2,3 (38) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 94: A‐MiII 5 BRK Sift to BR Dust 1,2,3 (38) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 95: A‐Mill Shorts (37) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 95: A‐Mill Shorts (37) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 96: A.MiII 3 LG (34) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 96: A.MiII 3 LG (34) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 97: A‐MiII 2 LG (35) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 97: A‐MiII 2 LG (35) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 98: A‐MiII BR‐SH Dust to Sift (36) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 98: A‐MiII BR‐SH Dust to Sift (36) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 99: A‐MiII 2 CLR  sends to  STRU 7: Filter 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

(50) Cyclone  12 A‐Mill Pneumatics Stack Vent 

EQUI 99: A‐MiII 2 CLR (50) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 100: A‐Mill 2 Mids (16) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 100: A‐Mill 2 Mids (16) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 101: A‐Mill 2 Mids (17) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 101: A‐Mill 2 Mids (17) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 102: A‐Mill 2 Mids (18) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 102: A‐Mill 2 Mids (18) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 103: A‐MiII 5 BRK 2 (19) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 103: A‐MiII 5 BRK 2 (19) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 104: A‐MiII 5 BRK 1 (20) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 104: A‐MiII 5 BRK 1 (20) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 105: A‐Mill 3 Mids (21) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics 

Page 15: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 15 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 105: A‐Mill 3 Mids (21) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 106: A‐Mill 3 Mids (22) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 106: A‐Mill 3 Mids (22) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 107: A‐Mill 6 Mids (25) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 107: A‐Mill 6 Mids (25) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 108: A‐Mill 4 Mids (23) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 108: A‐Mill 4 Mids (23) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 109: A‐Mill 5 Mids (24) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 109: A‐Mill 5 Mids (24) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 110: A‐Mill 1 Tails (26) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 110: A‐Mill 1 Tails (26) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 111: A‐Mill 2 SIZ (27) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 111: A‐Mill 2 SIZ  is controlled  TREA 7: Fabric 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

(27) Cyclone  by  Filter ‐ Low Temp, T<180 Degrees F 

EQUI 112: A‐Mill 1 Qual (28) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 112: A‐Mill 1 Qual (28) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 113: A‐Mill Suction (29) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 113: A‐Mill Suction (29) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 114: A‐Mill Wht Germ (39) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 114: A‐Mill Wht Germ (39) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 115: A‐MiII 4 BC (30) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 115: A‐MiII 4 BC (30) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 116: A‐Mill 2 Talls (31) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 116: A‐Mill 2 Talls (31) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 117: A‐Mill 7 Mids (32) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 117: A‐Mill 7 Mids (32) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 

Page 16: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 16 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 118: A‐MiII 1 LG (33) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 118: A‐MiII 1 LG (33) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 119: A‐Mill 5 BRK to Roll l Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 119: A‐Mill 5 BRK to Roll l Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 120: A‐Mill 4 BRK to Roll 2 Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 120: A‐Mill 4 BRK to Roll 2 Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 121: A Cyclone Airlock 41 Hopper 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 121: A Cyclone Airlock 41 Hopper 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 122: A‐Mill 1 MC to Roll (44) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 122: A‐Mill 1 MC to Roll (44) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 123: A‐Mill 2 MC to Roll (4s) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 123: A‐Mill 2 MC to Roll (4s) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 124: A‐Mill P4  sends to  STRU 7: Filter 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Purifier (46) Cyclone  12 A‐Mill Pneumatics Stack Vent 

EQUI 124: A‐Mill P4 Purifier (46) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 125: A‐Mill P13 (47) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 125: A‐Mill P13 (47) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 126: A‐Mill P9 (48) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 126: A‐Mill P9 (48) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 127: A‐Mill Germ/1T (48) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 127: A‐Mill Germ/1T (48) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 128: A‐Mill 2 SIZ to Roll (53) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 128: A‐Mill 2 SIZ to Roll (53) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 129: A‐Mill (50) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 129: A‐Mill (50) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 130: A‐Mill PAT/CLR (51) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics 

Page 17: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 17 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 130: A‐Mill PAT/CLR (51) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 131: A‐Mill 7M to Roll (52) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 131: A‐Mill 7M to Roll (52) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 132: A‐Mill 2T to Roll (54) Cyclone 

sends to  STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

EQUI 132: A‐Mill 2T to Roll (54) Cyclone 

is controlled by 

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 133: A Bran Duster 1 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 133: A Bran Duster 1 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 134: A Bran Duster 2 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 134: A Bran Duster 2 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 135: A Bran Duster 3 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 135: A Bran Duster 3 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 136: A P‐18 2/1 CLR Receiving Cyclone 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 136: A P‐18 2/1  is controlled  TREA 8: Fabric 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

CLR Receiving Cyclone  by  Filter ‐ Low Temp, T<180 Degrees F 

EQUI 137: A P4 Purifier  sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 137: A P4 Purifier  is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 138: A P9 & P13 Purifier 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 138: A P9 & P13 Purifier 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 139: A Shorts Duster 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 139: A Shorts Duster 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 140: A Shorts Duster 2 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 140: A Shorts Duster 2 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 141: A Patent Scale 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 141: A Patent Scale 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 142: Farina Purifier Airlock Hopper 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 142: Farina Purifier Airlock Hopper 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 

Page 18: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 18 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Degrees F 

EQUI 143: Germ Final Cyclone 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 143: Germ Final Cyclone 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 144: A Bran & Shorts Airlock Hopper 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 144: A Bran & Shorts Airlock Hopper 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 145: A Red Dog Duster Airlock Hopper 

sends to  STRU 8: Filter 13 A Mill Purifiers Stack Vent 

EQUI 145: A Red Dog Duster Airlock Hopper 

is controlled by 

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 146: Germ Aspirator Suction Cyclone 

sends to  STRU 9: Filter 14 A Mill Purifiers Stack Vent 

EQUI 146: Germ Aspirator Suction Cyclone 

is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 147: A Patent Splitter Cyclone 

sends to  STRU 9: Filter 14 A Mill Purifiers Stack Vent 

EQUI 147: A Patent Splitter Cyclone 

is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 148: Filter 14 Suction Air Horizontal Splitter 

sends to  STRU 9: Filter 14 A Mill Purifiers Stack Vent 

EQUI 148: Filter 14 Suction Air Horizontal Splitter 

is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 149: A P2 Purifier  sends to  STRU 9: Filter 

SI ID:  Description 

Relationship type 

Related SI ID: Description 14 A Mill Purifiers Stack Vent 

EQUI 149: A P2 Purifier  is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 150: A P1 Purifier  sends to  STRU 9: Filter 14 A Mill Purifiers Stack Vent 

EQUI 150: A P1 Purifier  is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 151: Germ Classifier 

sends to  STRU 9: Filter 14 A Mill Purifiers Stack Vent 

EQUI 151: Germ Classifier 

is controlled by 

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 152: Farina Purifier Cyclone 1 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 152: Farina Purifier Cyclone 1 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 153: Farina Purifier Cyclone 2 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 153: Farina Purifier Cyclone 2 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 154: B P1 & P2 Purifier 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 154: B P1 & P2 Purifier 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

Page 19: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 19 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 155: B P7 & P8 Purifier 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 155: B P7 & P8 Purifier 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 156: B P5 & P6 Purifier 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 156: B P5 & P6 Purifier 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 157: B P3 & P4 Purifier 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 157: B P3 & P4 Purifier 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 158: B P1 & P2 Purifier 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 158: B P1 & P2 Purifier 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 159: B Floor Cut In to Mill 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 159: B Floor Cut In to Mill 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 160: B Patent Scale 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 160: B Patent  is controlled  TREA 10: 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Scale  by  Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 161: B Red Dog Airlock Hopper 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 161: B Red Dog Airlock Hopper 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 162: B Clear to Bin Airlock Hopper 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 162: B Clear to Bin Airlock Hopper 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 163: B Patent to Sifter Airlock Hopper 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 163: B Patent to Sifter Airlock Hopper 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 164: B 2nd BRK Rollstand 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 164: B 2nd BRK Rollstand 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 165: B Patent to Bin Airlock Hopper 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 165: B Patent to Bin Airlock Hopper 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 166: B Patent 3  sends to  STRU 10: Filter 

Page 20: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 20 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Way Splitter Cyclone  15 B Mill Purifiers Stack Vent 

EQUI 166: B Patent 3 Way Splitter Cyclone 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 167: B Patent Flour Cyclone 

sends to  STRU 10: Filter 15 B Mill Purifiers Stack Vent 

EQUI 167: B Patent Flour Cyclone 

is controlled by 

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 168: B 3 BRK F (5) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 168: B 3 BRK F (5) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 169: B 3 BRK 1 (7) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 169: B 3 BRK 1 (7) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 170: B BRK Cuts (9) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 170: B BRK Cuts (9) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 171: B 1 MF (11) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 171: B 1 MF (11) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ 

SI ID:  Description 

Relationship type 

Related SI ID: Description Low Temp, T<180 Degrees F 

EQUI 172: B 2 Mids (13) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 172: B 2 Mids (13) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 173: B 2 BRK 3 (2) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 173: B 2 BRK 3 (2) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 174: B 2 BRK 2 (3) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 174: B 2 BRK 2 (3) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 175: B 2 BRK 1 (4) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 175: B 2 BRK 1 (4) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 176: B 3 BRK F (6) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 176: B 3 BRK F (6) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 177: B 3 BRK 2 (8) Cyclone 

sends to  STRU 11: Filter 16 B Mill 

Page 21: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 21 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Pneumatics Stack Vent 

EQUI 177: B 3 BRK 2 (8) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 178: B C SIZ (12) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 178: B C SIZ (12) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 179: B 1 MC (14) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 179: B 1 MC (14) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 180: B 1T (21) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 180: B 1T (21) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 181: B 5M Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 181: B 5M Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 182: B 3M (18) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 182: B 3M (18) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, 

SI ID:  Description 

Relationship type 

Related SI ID: Description T<180 Degrees F 

EQUI 183: B 4M (20) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 183: B 4M (20) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 184: B 5 BRK 1 (24) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 184: B 5 BRK 1 (24) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 185: B 5 BRK 2 (25) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 185: B 5 BRK 2 (25) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 186: B Pur Filt to 2T SIFT (28) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 186: B Pur Filt to 2T SIFT (28) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 187: B 2T (30) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 187: B 2T (30) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 188: B 2M (15) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics 

Page 22: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 22 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 188: B 2M (15) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 189: B Qual (17) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 189: B Qual (17) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 190: B 5M (16) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 190: B 5M (16) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 191: B F SIZ (10) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 191: B F SIZ (10) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 192: B 4 BRK Dust Sift (23) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 192: B 4 BRK Dust Sift (23) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 193: B 4 BRK 2 (26) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 193: B 4 BRK 2 (26) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees 

SI ID:  Description 

Relationship type 

Related SI ID: Description F 

EQUI 194: B 4 BRK 1 (27) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 194: B 4 BRK 1 (27) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 195: B 1 LG (29) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 195: B 1 LG (29) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 196: B 2 LG (31) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 196: B 2 LG (31) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 197: B 7M (32) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 197: B 7M (32) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 198: B 6M (33) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

EQUI 198: B 6M (33) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 199: B (34) Cyclone 

sends to  STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

Page 23: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 23 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 199: B (34) Cyclone 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 200: C P3 & P4 Purifiers 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 200: C P3 & P4 Purifiers 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 201: C P1 & P5 Purifiers 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 201: C P1 & P5 Purifiers 

is controlled by 

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 202: C P1 & P2 Farina Purifiers 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 202: C P1 & P2 Farina Purifiers 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 203: C Mill Pneumatic Vibrator Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 203: C Mill Pneumatic Vibrator Hopper 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 204: C 3/4 1 Rollstand 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 204: C 3/4 1 Rollstand 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 205: C Bran Rollstand 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 205: C Bran Rollstand 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 206: C 4/5 BRC Feed Conveyor 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 206: C 4/5 BRC Feed Conveyor 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 207: C 4/5 BKC Rollstand 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 207: C 4/5 BKC Rollstand 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 208: C 1/2 MC 1 Rollstand 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 208: C 1/2 MC 1 Rollstand 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 209: C 3 BK 2 Rollstand 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 209: C 3 BK 2 Rollstand 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 210: C FL 3 CLR to Bin Airlock Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 210: C FL 3 CLR  is controlled  TREA 12: 

Page 24: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 24 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

to Bin Airlock Hopper  by  Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 211: C FL 1 Patent to Bin Airlock Bench Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 211: C FL 1 Patent to Bin Airlock Bench Hopper 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 212: C Feed to B CH Airlock Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 212: C Feed to B CH Airlock Hopper 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 213: C FL 2 to RBLT Airlock Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 213: C FL 2 to RBLT Airlock Hopper 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 214: C FL 1 to RBLT Airlock Hopper 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 214: C FL 1 to RBLT Airlock Hopper 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 215: C FL 1 to RBLT Cyclone 

sends to  STRU 12: Filter 24 C Mill Purifiers Stack Vent 

EQUI 215: C FL 1 to RBLT Cyclone 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 216: C FL 2 to  sends to  STRU 12: Filter 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

RBLT Cyclone  24 C Mill Purifiers Stack Vent 

EQUI 216: C FL 2 to RBLT Cyclone 

is controlled by 

TREA 12: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 217: C Feed to RBLT Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 217: C Feed to RBLT Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 218: C FL 3 to RBLT Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 218: C FL 3 to RBLT Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 219: C 1/2 BK 1&2 (2) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 219: C 1/2 BK 1&2 (2) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 220: C 1/2 BK 1 (3) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 220: C 1/2 BK 1 (3) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 221: C 1/2 BK 2 Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 221: C 1/2 BK 2 Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ 

Page 25: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 25 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Low Temp, T<180 Degrees F 

EQUI 222: C GR 3 (23) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 222: C GR 3 (23) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 223: C GR 1/22 (22) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 223: C GR 1/22 (22) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 224: C Bran Relift Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 224: C Bran Relift Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 225: C 3 BK 1 (9) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 225: C 3 BK 1 (9) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 226: C 3 BKC 2 (13) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 226: C 3 BKC 2 (13) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 227: C Bran Dust 2 (15) Cyclone 

sends to  STRU 13: Filter 26 C Mill 

SI ID:  Description 

Relationship type 

Related SI ID: Description Pneumatics Stack Vent 

EQUI 227: C Bran Dust 2 (15) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 228: C 3/4 M (16) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 228: C 3/4 M (16) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 229: C 5/6 Mids (18) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 229: C 5/6 Mids (18) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 230: C B SIZ (1) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 230: C B SIZ (1) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 231: C A SIZ (4) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 231: C A SIZ (4) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 232: C 1/2 MC 1 (6) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 232: C 1/2 MC 1 (6) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, 

Page 26: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 26 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description T<180 Degrees F 

EQUI 233: C 1/2 MC 2 (7) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 233: C 1/2 MC 2 (7) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 234: C 1/2 MF (8) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 234: C 1/2 MF (8) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 235: C Qual (10) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 235: C Qual (10) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 236: C Filter Dust (11) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 236: C Filter Dust (11) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 237: C Bran Dust 1 (12) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 237: C Bran Dust 1 (12) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 238: C 4/5 BKC (14) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 238: C 4/5 BKC (14) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 239: C 4/5 BKF (17) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 239: C 4/5 BKF (17) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 240: C 1 TAIL (19) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 240: C 1 TAIL (19) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 241: C 1/2 LG (20) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 241: C 1/2 LG (20) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 242: C 7/8 M (21) Cyclone 

sends to  STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

EQUI 242: C 7/8 M (21) Cyclone 

is controlled by 

TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 243: L/O System 1 Collection Airlock Hopper 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 243: L/O System 1 Collection Airlock Hopper 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees 

Page 27: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 27 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description F 

EQUI 244: L/O System 2 Collection Airlock Hopper 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 244: L/O System 2 Collection Airlock Hopper 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 245: L/O System 3 Collection Airlock Hopper 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 245: L/O System 3 Collection Airlock Hopper 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 246: L/O Filter 17 Discharge Airlock Hopper 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 246: L/O Filter 17 Discharge Airlock Hopper 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 247: L/O Germ Collection Airlock Hopper 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 247: L/O Germ Collection Airlock Hopper 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 248: A Track Aspiration 1 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 248: A Track Aspiration 1 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 249: A Track Aspiration 1 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 249: A Track Aspiration 1 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 250: A Track Aspiration 1 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 250: A Track Aspiration 1 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 251: A Track Aspiration 1 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 251: A Track Aspiration 1 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 252: L/O System 1 Flour Collection Conveyor 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 252: L/O System 1 Flour Collection Conveyor 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 253: L/O System 2 Flour Collection Conveyor 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 253: L/O System 2 Flour Collection Conveyor 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 254: L/O System 3 Flour Collection Conveyor 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 254: L/O System 3 Flour Collection Conveyor 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

Page 28: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 28 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 255: Farina Collection Cyclone 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 255: Farina Collection Cyclone 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 256: L/O Truck Transfer Cyclone 

sends to  STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

EQUI 256: L/O Truck Transfer Cyclone 

is controlled by 

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 257: L/O System 1 Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 257: L/O System 1 Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 258: L/O System 2 Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 258: L/O System 2 Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 259: L/O System 3 Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 259: L/O System 3 Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 260: Flour Storage Bin 1 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 260: Flour Storage Bin 1 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 261: Flour Storage Bin 2 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 261: Flour Storage Bin 2 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 262: Flour Storage Bin 3 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 262: Flour Storage Bin 3 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 263: Flour Storage Bin 4 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 263: Flour Storage Bin 4 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 264: Flour Storage Bin 5 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 264: Flour Storage Bin 5 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 265: Flour Storage Bin 6 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 265: Flour Storage Bin 6 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 266: Flour Storage Bin 7 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 266: Flour Storage Bin 7 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 267: Flour Storage Bin 8 

sends to  STRU 15: Filter 18 Bulk Plant 

Page 29: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 29 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 267: Flour Storage Bin 8 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 268: Flour Storage Bin 9 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 268: Flour Storage Bin 9 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 269: Flour Storage Bin 10 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 269: Flour Storage Bin 10 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 270: C Patent Flour Conveyor Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 270: C Patent Flour Conveyor Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 271: A Patent Flour Conveyor Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 271: A Patent Flour Conveyor Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 272: Farina Final Product Sifter Cyclone 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 272: Farina Final Product Sifter Cyclone 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 273: Flour Storage Bin 11 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 273: Flour  is controlled  TREA 15: 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Storage Bin 11  by  Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 274: Flour Storage Bin 12 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 274: Flour Storage Bin 12 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 275: Flour Storage Bin 13 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 275: Flour Storage Bin 13 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 276: Flour Storage Bin 14 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 276: Flour Storage Bin 14 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 277: Flour Storage Bin 15 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 277: Flour Storage Bin 15 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 278: Flour Storage Bin 16 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 278: Flour Storage Bin 16 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 279: Flour Storage Bin 17 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 279: Flour Storage Bin 17 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, 

Page 30: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 30 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description T<180 Degrees F 

EQUI 280: Flour Storage Bin 18 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 280: Flour Storage Bin 18 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 281: Flour Storage Bin 19 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 281: Flour Storage Bin 19 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 282: Flour Storage Bin 20 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 282: Flour Storage Bin 20 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 283: Off Flour Bin  sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 283: Off Flour Bin  is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 284: Final Product Garner Scale System 1 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 284: Final Product Garner Scale System 1 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 285: Final Product Garner Scale System 2 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 285: Final Product Garner Scale System 2 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

EQUI 286: Final Product Garner Scale System 3 

sends to  STRU 15: Filter 18 Bulk Plant Stack Vent 

EQUI 286: Final Product Garner Scale System 3 

is controlled by 

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 287: Truck L/O Bin 1 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 287: Truck L/O Bin 1 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 288: Truck L/O Bin 2 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 288: Truck L/O Bin 2 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 289: Truck L/O Bin 3 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 289: Truck L/O Bin 3 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 290: Truck L/O Bin 4 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 290: Truck L/O Bin 4 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 291: Truck L/O Bin 5 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 291: Truck L/O Bin 5 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 292: Truck L/O Bin 6 

sends to  STRU 16: Filter 19 Truck L/O 

Page 31: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 31 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description Stack Vent 

EQUI 292: Truck L/O Bin 6 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 293: Truck L/O Bin 7 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 293: Truck L/O Bin 7 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 294: Truck L/O Bin 8 

sends to  STRU 16: Filter 19 Truck L/O Stack Vent 

EQUI 294: Truck L/O Bin 8 

is controlled by 

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 295: B&C Mill Feed Airlock Cyclone 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 296: Feed Distribution Center Airlock Cyclone 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 297: Feed Distribution South Airlock Cyclone 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 298: Feed Distribution South Conveyor 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 299: Feed Distribution Center Conveyor 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed 

SI ID:  Description 

Relationship type 

Related SI ID: Description Loadout Stack Vent 

EQUI 300: Feed Distribution Cross Conveyor 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 301: South Feed Bins Collection Screw 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 302: North Feed Bins Collection Screw 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 303: Truck Feed Loadout Screw Conveyor 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 304: Feed Loadout Hood 

sends to  STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

EQUI 305: Boiler  sends to  STRU 17: Boiler Stack Vent 

EQUI 306: Hoffman Vacuum A 

sends to  STRU 18: Millhouse ‐ Hoffman Vacuum System A Stack Vent 

EQUI 306: Hoffman Vacuum A 

is controlled by 

TREA 17: Fabric Filter ‐ Low Temp, T<180 Degrees F 

EQUI 307: Hoffman Vacuum B 

sends to  STRU 19: Millhouse ‐ Hoffman Vacuum 

Page 32: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 32 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description System B Stack Vent 

EQUI 307: Hoffman Vacuum B 

is controlled by 

TREA 18: Fabric Filter ‐ Low Temp, T<180 Degrees F 

FUGI 4: Fugitive HAP Sources (Fumigation, Preservation, etc.) 

    

STRU 1: Filter 01 Grain Receiving Stack Vent 

    

STRU 2: Filter 02 Elevator Stack Grain Handling Vent 

    

STRU 3: Filter 06 C‐Mill Cleaning House Stack Vent 

    

STRU 4: Filter 08 B‐Mill Cleaning House Stack Vent 

    

STRU 5: Filter 27 A‐Mill Cleaning House & Feed Loadout Stack Vent 

    

STRU 6: Filter 11 A‐Mill Pneumatics Stack Vent 

    

STRU 7: Filter 12 A‐Mill Pneumatics Stack Vent 

    

STRU 8: Filter 13 A Mill Purifiers Stack Vent 

    

STRU 9: Filter 14 A Mill Purifiers Stack Vent 

    

STRU 10: Filter 15 B Mill Purifiers Stack Vent 

    

STRU 11: Filter 16 B Mill Pneumatics Stack Vent 

    

STRU 12: Filter 24 C Mill Purifiers Stack Vent 

    

STRU 13: Filter 26 C Mill Pneumatics Stack Vent 

    

STRU 14: Filter 17 Flour Blending Stack Vent; Kice 

    

STRU 15: Filter 18 Bulk Plant Stack Vent 

    

STRU 16: Filter 19      

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Truck L/O Stack Vent STRU 17: Boiler Stack Vent 

    

STRU 18: Millhouse ‐ Hoffman Vacuum System A Stack Vent 

    

STRU 19: Millhouse ‐ Hoffman Vacuum System B Stack Vent 

    

STRU 20: Truck/Rail Unload Shed 

    

STRU 21: Grain Elevator Leg House 

    

STRU 22: Grain Elevator OId House Storage Bins 

    

STRU 23: Grain Elevator New House Storage Bins 

    

STRU 24: Cleaning House & A Mill 

    

STRU 25: B & C Mills      STRU 26: Bulk Plant      STRU 27: Truck Load Out 

    

STRU 28: Rail Load Out      STRU 29: Feed Plant      STRU 30: Feed Load Out Shed 

    

STRU 31: Boiler Room      STRU 32: Maintenance Shop (No Stacks/Vents) 

    

STRU 33: Warehouse (No Stacks/Vents) 

    

STRU 34: Office (No Stacks/Vents) 

    

TREA 1: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 2: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 3: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 4: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 5: Fabric Filter ‐      

Page 33: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 33 of 109 

  

 

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Low Temp, T<180 Degrees F TREA 6: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 7: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 8: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 9: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 10: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 11: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 12: Fabric Filter ‐ Low Temp, T<180 

    

SI ID:  Description 

Relationship type 

Related SI ID: Description 

Degrees F TREA 13: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 14: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 15: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 16: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 17: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

TREA 18: Fabric Filter ‐ Low Temp, T<180 Degrees F 

    

    

Page 34: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 34 of 109 

  

 

 5. Limits and other requirements  

Requirement number  Requirement and citation 

TFAC 1  Ardent Mills LLC 

5.1.1  Process Throughput <= 402,960 tons per year 12‐month rolling sum of grain received to be calculated by the 15th day of each month for the previous 12‐month period as described in this permit. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.1.2  Process Throughput: Daily Recordkeeping. On each day of operation, the Permittee shall calculate, record, and maintain the total quantity of grain received at the facility in tons. Records shall be based on written or electronic records. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.1.3  Process Throughput: Monthly Recordkeeping. By the 15th of the month, the Permittee shall calculate and record the following:  1) The total quantity of grain received for the previous calendar month using the daily throughput records as required by this permit; and 2) The 12‐month rolling sum of grain received for the previous 12‐month period by summing the monthly records for the previous 12 months. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.1.4  The Permittee shall clean up commodities spilled on the driveway and other facility property as required to minimize fugitive emissions to a level consistent with RACT (reasonably available control technology). [Minn. R. 7011.1005, subp. 1(A)] 

5.1.5  Permit Appendices: This permit contains appendices as listed in the permit Table of Contents. The Permittee shall comply with all requirements contained in Appendix A. insignificant Activities and General Applicable Requirements and Appendix B. Alternative Test Method for Opacity Determination of Emissions from Intermittent Dust‐Generating Operations. [Minn. R. 7007.0800, subp. 2(A)] 

5.1.6  PERMIT SHIELD: Subject to the limitations in Minn. R. 7007.1800, compliance with the conditions of this permit shall be deemed compliance with the specific provision of the applicable requirement identified in the permit as the basis of each condition. Subject to the limitations of Minn. R. 7007.1800 and 7017.0100, subp. 2, notwithstanding the conditions of this permit specifying compliance practices for applicable requirements, any person (including the Permittee) may also use other credible evidence to establish compliance or noncompliance with applicable requirements.  This permit shall not alter or affect the liability of the Permittee for any violation of applicable requirements prior to or at the time of permit issuance. [Minn. R. 7007.1800(A)(2)] 

5.1.7  Comply with Fugitive Emission Control Plan: The Permittee shall follow the actions and recordkeeping specified in the fugitive dust control plan in Appendix C of this permit. If the Commissioner determines the Permittee is out of compliance with Minn. R. 7011.0150 or the fugitive control plan, then the Permittee may be required to amend the control plan and/or to install and operate particulate matter ambient monitors as requested by the Commissioner. [Minn. R. 7007.0100, Minn. R. 7007.0800, subp. 2, Minn. R. 7009.0020, Minn. R. 7011.0150, Minn. Stat. 116.07, subd. 4a] 

5.1.8  Circumvention: Do not install or use a device or means that conceals or dilutes emissions, which would otherwise violate a federal or state air pollution control rule, without reducing the total amount of pollutant emitted. [Minn. R. 7011.0020] 

5.1.9  Air Pollution Control Equipment: Operate all pollution control equipment whenever the corresponding process equipment and emission units are operated. [Minn. R. 7007.0800, subp. 16(J), 

Page 35: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 35 of 109 

  

 

Requirement number  Requirement and citation Minn. R. 7007.0800, subp. 2(A)] 

5.1.10  Operation and Maintenance Plan: Retain at the stationary source an operation and maintenance plan for all air pollution control equipment. At a minimum, the O & M plan shall identify all air pollution control equipment and control practices and shall include a preventative maintenance program for the equipment and practices, a description of (the minimum but not necessarily the only) corrective actions to be taken to restore the equipment and practices to proper operation to meet applicable permit conditions, a description of the employee training program for proper operation and maintenance of the control equipment and practices, and the records kept to demonstrate plan implementation. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 16(J)] 

5.1.11  Operation Changes: In any shutdown, breakdown, or deviation the Permittee shall immediately take all practical steps to modify operations to reduce the emission of any regulated air pollutant. The Commissioner may require feasible and practical modifications in the operation to reduce emissions of air pollutants. No emissions units that have an unreasonable shutdown or breakdown frequency of process or control equipment shall be permitted to operate. [Minn. R. 7019.1000, subp. 4] 

5.1.12  Fugitive Emissions: Do not cause or permit the handling, use, transporting, or storage of any material in a manner which may allow avoidable amounts of particulate matter to become airborne. Comply with all other requirements listed in Minn. R. 7011.0150. [Minn. R. 7011.0150] 

5.1.13  Noise: The Permittee shall comply with the noise standards set forth in Minn. R. 7030.0010 to 7030.0080 at all times during the operation of any emission units. This is a state only requirement and is not enforceable by the EPA Administrator or citizens under the Clean Air Act. [Minn. R. 7030.0010‐7030.0080] 

5.1.14  Inspections: The Permittee shall comply with the inspection procedures and requirements as found in Minn. R. 7007.0800, subp. 9(A). [Minn. R. 7007.0800, subp. 9(A)] 

5.1.15  The Permittee shall comply with the General Conditions listed in Minn. R. 7007.0800, subp. 16. [Minn. R. 7007.0800, subp. 16] 

5.1.16  Performance Testing: Conduct all performance tests in accordance with Minn. R. ch. 7017 unless otherwise noted in this permit. [Minn. R. ch. 7017] 

5.1.17  Performance Test Notifications and Submittals:  Performance Test Notification and Plan: due 30 days before each Performance Test Performance Test Pre‐test Meeting: due 7 days before each Performance Test Performance Test Report: due 45 days after each Performance Test  The Notification, Test Plan, and Test Report must be submitted in a format specified by the commissioner. [Minn. R. 7017.2017, Minn. R. 7017.2030, subps. 1‐4, Minn. R. 7017.2035, subps. 1‐2] 

5.1.18  Limits set as a result of a performance test (conducted before or after permit issuance) apply until superseded as stated in the MPCA's Notice of Compliance letter granting preliminary approval. Preliminary approval is based on formal review of a subsequent performance test on the same unit as specified by Minn. R. 7017.2025, subp. 3. The limit is final upon issuance of a permit amendment incorporating the change. [Minn. R. 7017.2025, subp. 3] 

5.1.19  Monitoring Equipment Calibration ‐ The Permittee shall either:  1. Calibrate or replace required monitoring equipment every 12 months; or 2. Calibrate at the frequency stated in the manufacturer's specifications.  For each monitor, the Permittee shall maintain a record of all calibrations, including the date conducted, and any corrective action that resulted. The Permittee shall include the calibration frequencies, procedures, and manufacturer's specifications (if applicable) in the Operations and Maintenance Plan. Any requirements applying to continuous emission monitors are listed separately 

Page 36: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 36 of 109 

  

 

Requirement number  Requirement and citation in this permit. [Minn. R. 7007.0800, subp. 4(D)] 

5.1.20  Operation of Monitoring Equipment: Unless noted elsewhere in this permit, monitoring a process or control equipment connected to that process is not necessary during periods when the process is shutdown, or during checks of the monitoring systems, such as calibration checks and zero and span adjustments. If monitoring records are required, they should reflect any such periods of process shutdown or checks of the monitoring system. [Minn. R. 7007.0800, subp. 4(D)] 

5.1.21  Recordkeeping: Retain all records at the stationary source, unless otherwise specified within this permit, for a period of five (5) years from the date of monitoring, sample, measurement, or report. Records which must be retained at this location include all calibration and maintenance records, all original recordings for continuous monitoring instrumentation, and copies of all reports required by the permit. Records must conform to the requirements listed in Minn. R. 7007.0800, subp. 5(A). [Minn. R. 7007.0800, subp. 5(C)] 

5.1.22  Recordkeeping: Maintain records describing any insignificant modifications (as required by Minn. R. 7007.1250, subp. 3) or changes contravening permit terms (as required by Minn. R. 7007.1350, subp. 2), including records of the emissions resulting from those changes. [Minn. R. 7007.0800, subp. 5(B)] 

5.1.23  If the Permittee determines that no permit amendment or notification is required prior to making a change, the Permittee must retain records of all calculations required under Minn. R. 7007.1200. For non‐expiring permits, these records shall be kept for a period of five years from the date that the change was made. The records shall be kept at the stationary source for the current calendar year of operation and may be kept at the stationary source or office of the stationary source for all other years. The records may be maintained in either electronic or paper format. [Minn. R. 7007.1200, subp. 4] 

5.1.24  Shutdown Notifications: Notify the Commissioner at least 24 hours in advance of a planned shutdown of any control equipment or process equipment if the shutdown would cause any increase in the emissions of any regulated air pollutant. If the owner or operator does not have advance knowledge of the shutdown, notification shall be made to the Commissioner as soon as possible after the shutdown. However, notification is not required in the circumstances outlined in items A, B, and C of Minn. R. 7019.1000, subp. 3.  At the time of notification, the owner or operator shall inform the Commissioner of the cause of the shutdown and the estimated duration. The owner or operator shall notify the Commissioner when the shutdown is over. [Minn. R. 7019.1000, subp. 3] 

5.1.25  Breakdown Notifications: Notify the Commissioner within 24 hours of a breakdown of more than one hour duration of any control equipment or process equipment if the breakdown causes any increase in the emissions of any regulated air pollutant. The 24‐hour time period starts when the breakdown was discovered or reasonably should have been discovered by the owner or operator. However, notification is not required in the circumstances outlined in items A, B, and C of Minn. R. 7019.1000, subp. 2.  At the time of notification or as soon as possible thereafter, the owner or operator shall inform the Commissioner of the cause of the breakdown and the estimated duration. The owner or operator shall notify the Commissioner when the breakdown is over. [Minn. R. 7019.1000, subp. 2] 

5.1.26  Notification of Deviations Endangering Human Health or the Environment: As soon as possible after discovery, notify the Commissioner or the state duty officer, either orally or by facsimile, of any deviation from permit conditions which could endanger human health or the environment. [Minn. R. 7019.1000, subp. 1] 

5.1.27  Notification of Deviations Endangering Human Health or the Environment Report: Within 2 working days of discovery, notify the Commissioner in writing of any deviation from permit conditions which could endanger human health or the environment. Include the following information in this written 

Page 37: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 37 of 109 

  

 

Requirement number  Requirement and citation description: 1. the cause of the deviation;  2. the exact dates of the period of the deviation, if the deviation has been corrected; 3. whether or not the deviation has been corrected;  4. the anticipated time by which the deviation is expected to be corrected, if not yet corrected; and  5. steps taken or planned to reduce, eliminate, and prevent reoccurrence of the deviation. [Minn. R. 7019.1000, subp. 1] 

5.1.28  Application for Permit Amendment: If a permit amendment is needed, submit an application in accordance with the requirements of Minn. R. 7007.1150 through Minn. R. 7007.1500. Submittal dates vary, depending on the type of amendment needed.  Upon adoption of a new or amended federal applicable requirement, and if there are 3 or more years remaining in the permit term, the Permittee shall file an application for an amendment within nine months of promulgation of the applicable requirement, pursuant to Minn. R. 7007.0400, subp. 3. [Minn. R. 7007.0400, subp. 3, Minn. R. 7007.1150 ‐ 7007.1500] 

5.1.29  Extension Requests: The Permittee may apply for an Administrative Amendment to extend a deadline in a permit by no more than 120 days, provided the proposed deadline extension meets the requirements of Minn. R. 7007.1400, subp. 1(H). Performance testing deadlines from the General Provisions of 40 CFR pt. 60 and pt. 63 are examples of deadlines for which the MPCA does not have authority to grant extensions and therefore do not meet the requirements of Minn. R. 7007.1400, subp. 1(H). [Minn. R. 7007.1400, subp. 1(H)] 

5.1.30  Emission Inventory Report: due on or before April 1 of each calendar year following permit issuance. Submit in a format specified by the Commissioner. [Minn. R. 7019.3000‐7019.3100] 

5.1.31  Emission Fees: due 30 days after receipt of an MPCA bill. [Minn. R. 7002.0005‐7002.0085] 

COMG 1  Flour Blending & Truck Loading 

5.2.1  Opacity <= 10 percent opacity from truck loading stations fugitive emissions. [Minn. R. 7011.1005, subp. 3(B)] 

COMG 2  Feed Loadout 

5.3.1  Opacity <= 10 percent opacity from truck loading stations fugitive emissions. [Minn. R. 7011.1005, subp. 3(B)] 

EQUI 1  Rail and Truck Unload Pit 

5.4.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

EQUI 2  Rail Receiving Leg 

5.5.1  The Permittee shall vent emissions from EQUI 2 to control equipment meeting the requirements of TREA 1 whenever EQUI 2 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 3  Elevator to Mill Wheat Leg 

5.6.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.6.2  The Permittee shall vent emissions from EQUI 3 to control equipment meeting the requirements of TREA 2 whenever EQUI 3 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 4  Elevator Unload Scale 

5.7.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.7.2  The Permittee shall vent emissions from EQUI 4 to control equipment meeting the requirements of 

Page 38: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 38 of 109 

  

 

Requirement number  Requirement and citation TREA 2 whenever EQUI 4 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 6  North Aspirator 

5.8.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.8.2  The Permittee shall vent emissions from EQUI 6 to control equipment meeting the requirements of TREA 2 whenever EQUI 6 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 7  South Aspirator 

5.9.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.9.2  The Permittee shall vent emissions from EQUI 7 to control equipment meeting the requirements of TREA 2 whenever EQUI 7 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 8  C‐14 Conveyor 

5.10.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.10.2  The Permittee shall vent emissions from EQUI 8 to control equipment meeting the requirements of TREA 2 whenever EQUI 8 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 9  C‐12 Conveyor 

5.11.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.11.2  The Permittee shall vent emissions from EQUI 9 to control equipment meeting the requirements of TREA 2 whenever EQUI 9 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 10  C‐15 Conveyor 

5.12.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.12.2  The Permittee shall vent emissions from EQUI 10 to control equipment meeting the requirements of TREA 2 whenever EQUI 10 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 11  C‐16 Conveyor 

5.13.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.13.2  The Permittee shall vent emissions from EQUI 11 to control equipment meeting the requirements of TREA 2 whenever EQUI 11 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 12  Elevator 3rd Floor Cyclone 

5.14.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.14.2  The Permittee shall vent emissions from EQUI 12 to control equipment meeting the requirements of TREA 2 whenever EQUI 12 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 15  C‐27 Conveyor 

Page 39: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 39 of 109 

  

 

Requirement number  Requirement and citation 

5.15.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.15.2  The Permittee shall vent emissions from EQUI 15 to control equipment meeting the requirements of TREA 2 whenever EQUI 15 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 16  C‐19 Conveyor 

5.16.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.16.2  The Permittee shall vent emissions from EQUI 16 to control equipment meeting the requirements of TREA 2 whenever EQUI 16 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 17  C‐18 Conveyor 

5.17.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.17.2  The Permittee shall vent emissions from EQUI 17 to control equipment meeting the requirements of TREA 2 whenever EQUI 17 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 18  C‐21 Conveyor 

5.18.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.18.2  The Permittee shall vent emissions from EQUI 18 to control equipment meeting the requirements of TREA 2 whenever EQUI 18 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 19  Mixed Wheat Leg 

5.19.1  Opacity <= 5 percent opacity from truck unloading stations, railcar unloading stations, railcar loading stations, and handling operation fugitive emissions. [Minn. R. 7011.1005, subp. 3(A)] 

5.19.2  The Permittee shall vent emissions from EQUI 19 to control equipment meeting the requirements of TREA 2 whenever EQUI 19 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 20  C‐Mill Surge Bin 

5.20.1  The Permittee shall vent emissions from EQUI 20 to control equipment meeting the requirements of TREA 3 whenever EQUI 20 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 21  C‐Mill Technovator Cyclone 

5.21.1  The Permittee shall vent emissions from EQUI 21 to control equipment meeting the requirements of TREA 3 whenever EQUI 21 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 22  C‐Mill Feed Cyclone 

5.22.1  The Permittee shall vent emissions from EQUI 22 to control equipment meeting the requirements of TREA 3 whenever EQUI 22 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 23  C‐Mill Screenings Cyclone 

5.23.1  The Permittee shall vent emissions from EQUI 23 to control equipment meeting the requirements of TREA 3 whenever EQUI 23 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 40: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 40 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 24  C‐Mill Combi‐Cleaner 

5.24.1  The Permittee shall vent emissions from EQUI 24 to control equipment meeting the requirements of TREA 3 whenever EQUI 24 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 25  C‐MiII WTR Scourer 

5.25.1  The Permittee shall vent emissions from EQUI 25 to control equipment meeting the requirements of TREA 3 whenever EQUI 25 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 26  C‐Mill Wheat to Roll Scale 

5.26.1  The Permittee shall vent emissions from EQUI 26 to control equipment meeting the requirements of TREA 3 whenever EQUI 26 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 27  C‐Mill 1/2 BK Rollstand 

5.27.1  The Permittee shall vent emissions from EQUI 27 to control equipment meeting the requirements of TREA 3 whenever EQUI 27 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 28  C‐Mill Clears Hopper 

5.28.1  The Permittee shall vent emissions from EQUI 28 to control equipment meeting the requirements of TREA 3 whenever EQUI 28 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 29  C‐Mill Red Dog Hopper 

5.29.1  The Permittee shall vent emissions from EQUI 29 to control equipment meeting the requirements of TREA 3 whenever EQUI 29 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 30  B/C Mill Corn Hopper 

5.30.1  The Permittee shall vent emissions from EQUI 30 to control equipment meeting the requirements of TREA 3 whenever EQUI 30 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 31  C‐Mill Temp Hopper 

5.31.1  The Permittee shall vent emissions from EQUI 31 to control equipment meeting the requirements of TREA 3 whenever EQUI 31 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 32  C‐Mill CH Screenings Scale Hopper 

5.32.1  The Permittee shall vent emissions from EQUI 32 to control equipment meeting the requirements of TREA 3 whenever EQUI 32 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 33  C‐Mill Clean Wheat Scale Hopper 

5.33.1  The Permittee shall vent emissions from EQUI 33 to control equipment meeting the requirements of TREA 3 whenever EQUI 33 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 34  Hammer Mills Cyclone 

5.34.1  The Permittee shall vent emissions from EQUI 34 to control equipment meeting the requirements of TREA 4 whenever EQUI 34 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 35  B‐Mill Bran Cyclone 

Page 41: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 41 of 109 

  

 

Requirement number  Requirement and citation 

5.35.1  The Permittee shall vent emissions from EQUI 35 to control equipment meeting the requirements of TREA 4 whenever EQUI 35 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 36  B‐Mill Shorts Cyclone 

5.36.1  The Permittee shall vent emissions from EQUI 36 to control equipment meeting the requirements of TREA 4 whenever EQUI 36 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 37  B‐Mill Screenings Cyclone 

5.37.1  The Permittee shall vent emissions from EQUI 37 to control equipment meeting the requirements of TREA 4 whenever EQUI 37 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 38  B‐Mill Combi‐Cleaner 

5.38.1  The Permittee shall vent emissions from EQUI 38 to control equipment meeting the requirements of TREA 4 whenever EQUI 38 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 39  Screenings Sifter Feed Conveyor 

5.39.1  The Permittee shall vent emissions from EQUI 39 to control equipment meeting the requirements of TREA 4 whenever EQUI 39 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 40  B/C Mills Feed Hopper 

5.40.1  The Permittee shall vent emissions from EQUI 40 to control equipment meeting the requirements of TREA 4 whenever EQUI 40 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 41  B‐Mill Wheat to Temper Hopper 

5.41.1  The Permittee shall vent emissions from EQUI 41 to control equipment meeting the requirements of TREA 4 whenever EQUI 41 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 43  B‐Mill Cleaning House Dirty Wheat Scale 

5.42.1  The Permittee shall vent emissions from EQUI 43 to control equipment meeting the requirements of TREA 4 whenever EQUI 43 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 44  B‐Mill Tecnovator Cyclone 

5.43.1  The Permittee shall vent emissions from EQUI 44 to control equipment meeting the requirements of TREA 4 whenever EQUI 44 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 45  B‐Mill Wheat to Mill Hopper 

5.44.1  The Permittee shall vent emissions from EQUI 45 to control equipment meeting the requirements of TREA 4 whenever EQUI 45 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 46  A‐Mill Wheat to Temper Hopper 

5.45.1  The Permittee shall vent emissions from EQUI 46 to control equipment meeting the requirements of TREA 5 whenever EQUI 46 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 47  A‐Mill Screenings Conveyor 

5.46.1  The Permittee shall vent emissions from EQUI 47 to control equipment meeting the requirements of 

Page 42: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 42 of 109 

  

 

Requirement number  Requirement and citation TREA 5 whenever EQUI 47 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 48  A‐Mill Feed to Bin Hopper 

5.47.1  The Permittee shall vent emissions from EQUI 48 to control equipment meeting the requirements of TREA 5 whenever EQUI 48 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 49  A‐Mill Wheat to Mill Scale Hopper 

5.48.1  The Permittee shall vent emissions from EQUI 49 to control equipment meeting the requirements of TREA 5 whenever EQUI 49 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 50  A‐Mill Screenings Hopper 

5.49.1  The Permittee shall vent emissions from EQUI 50 to control equipment meeting the requirements of TREA 5 whenever EQUI 50 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 51  A‐Mill Temper Bin Collection Screw 

5.50.1  The Permittee shall vent emissions from EQUI 51 to control equipment meeting the requirements of TREA 5 whenever EQUI 51 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 52  A‐Mill Wheat to Mill Hopper 

5.51.1  The Permittee shall vent emissions from EQUI 52 to control equipment meeting the requirements of TREA 5 whenever EQUI 52 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 53  A‐Mill Combi Cleaner 

5.52.1  The Permittee shall vent emissions from EQUI 53 to control equipment meeting the requirements of TREA 5 whenever EQUI 53 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 54  A‐Mill Wheat to Surge Bin Aspiration Fan 

5.53.1  The Permittee shall vent emissions from EQUI 54 to control equipment meeting the requirements of TREA 5 whenever EQUI 54 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 55  A‐Mill Wheat to Surge Bin Scourer 

5.54.1  The Permittee shall vent emissions from EQUI 55 to control equipment meeting the requirements of TREA 5whenever EQUI 55 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 56  A‐Mill Pre Break L12 Rollstand 

5.55.1  The Permittee shall vent emissions from EQUI 56 to control equipment meeting the requirements of TREA 5 whenever EQUI 56 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 57  A‐Mill Pre Break 3/4 Rollstand 

5.56.1  The Permittee shall vent emissions from EQUI 57 to control equipment meeting the requirements of TREA 5 whenever EQUI 57 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 58  A‐Mill Pre Break 5/6 Rollstand 

5.57.1  The Permittee shall vent emissions from EQUI 58 to control equipment meeting the requirements of TREA 5 whenever EQUI 58 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 43: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 43 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 60  A‐Miil Technovator Hopper 

5.58.1  The Permittee shall vent emissions from EQUI 60 to control equipment meeting the requirements of TREA 5 whenever EQUI 60 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 61  A‐Mill Screenings Cyclone 1 

5.59.1  The Permittee shall vent emissions from EQUI 61 to control equipment meeting the requirements of TREA 5 whenever EQUI 61 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 62  A‐Mill Screenings Cyclone 2 

5.60.1  The Permittee shall vent emissions from EQUI 62 to control equipment meeting the requirements of TREA 5 whenever EQUI 62 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 63  A‐Mill Screenings Cyclone 3 

5.61.1  The Permittee shall vent emissions from EQUI 63 to control equipment meeting the requirements of TREA 5 whenever EQUI 63 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 64  Elevator Screenings Cyclone 

5.62.1  The Permittee shall vent emissions from EQUI 64 to control equipment meeting the requirements of TREA 5 whenever EQUI 64 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 65  A‐Mill Wheat Temper Receiving Hopper 

5.63.1  The Permittee shall vent emissions from EQUI 65 to control equipment meeting the requirements of TREA 5 whenever EQUI 65 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 66  A‐Mill P‐13 Cyclone 

5.64.1  The Permittee shall vent emissions from EQUI 66 to control equipment meeting the requirements of TREA 5 whenever EQUI 66 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 67  A‐Mill 40 Cyclone 

5.65.1  The Permittee shall vent emissions from EQUI 67 to control equipment meeting the requirements of TREA 6 whenever EQUI 67 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 68  A‐Mill 41 Cyclone 

5.66.1  The Permittee shall vent emissions from EQUI 68 to control equipment meeting the requirements of TREA 6 whenever EQUI 68 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 69  A‐Mill 42 Cyclone 

5.67.1  The Permittee shall vent emissions from EQUI 69 to control equipment meeting the requirements of TREA 6 whenever EQUI 69 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 70  Cut Stream 3‐Way Splitter Cyclone 

5.68.1  The Permittee shall vent emissions from EQUI 70 to control equipment meeting the requirements of TREA 6 whenever EQUI 70 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 71  A‐MiII 3 BRK 1(3) Cyclone 

Page 44: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 44 of 109 

  

 

Requirement number  Requirement and citation 

5.69.1  The Permittee shall vent emissions from EQUI 71 to control equipment meeting the requirements of TREA 6 whenever EQUI 71 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 72  A‐MiII 2 BRK 1,2 (4) Cyclone 

5.70.1  The Permittee shall vent emissions from EQUI 72 to control equipment meeting the requirements of TREA 6 whenever EQUI 72 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 73  A‐MiII 3 BRK 2 (5) Cyclone 

5.71.1  The Permittee shall vent emissions from EQUI 73 to control equipment meeting the requirements of TREA 6 whenever EQUI 73 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 74  A‐MiII 4 BRK 1 (6) Cyclone 

5.72.1  The Permittee shall vent emissions from EQUI 74 to control equipment meeting the requirements of TREA 6 whenever EQUI 74 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 75  A.MiII A,B SIZ (8) Cyclone 

5.73.1  The Permittee shall vent emissions from EQUI 75 to control equipment meeting the requirements of TREA 6 whenever EQUI 75 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 76  A‐Mill A,B SIZ (8) Cyclone 

5.74.1  The Permittee shall vent emissions from EQUI 76 to control equipment meeting the requirements of TREA 6 whenever EQUI 76 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 77  A‐Mill C SIZ (9) Cyclone 

5.75.1  The Permittee shall vent emissions from EQUI 77 to control equipment meeting the requirements of TREA 6 whenever EQUI 77 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 78  A‐Mill SIZ A/B (Split w/ 8) Cylcone 

5.76.1  The Permittee shall vent emissions from EQUI 78 to control equipment meeting the requirements of TREA 6 whenever EQUI 78 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 79  A‐Mill 1 Midds C (10) Cyclone 

5.77.1  The Permittee shall vent emissions from EQUI 79 to control equipment meeting the requirements of TREA 6 whenever EQUI 79 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 80  A‐Mill 1 Midds B (11) Cyclone 

5.78.1  The Permittee shall vent emissions from EQUI 80 to control equipment meeting the requirements of TREA 6 whenever EQUI 80 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 81  A‐Mill 1 Mids A (12) Cyclone 

5.79.1  The Permittee shall vent emissions from EQUI 81 to control equipment meeting the requirements of TREA 6 whenever EQUI 81 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 82  A‐Mill 5 Bran F (13) Cyclone 

5.80.1  The Permittee shall vent emissions from EQUI 82 to control equipment meeting the requirements of 

Page 45: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 45 of 109 

  

 

Requirement number  Requirement and citation TREA 6 whenever EQUI 82 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 83  A‐Mill 1,2,3 BC (14) Cyclone 

5.81.1  The Permittee shall vent emissions from EQUI 83 to control equipment meeting the requirements of TREA 6 whenever EQUI 83 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 84  A‐Mill 1,2,3 BC (15) Cyclone 

5.82.1  The Permittee shall vent emissions from EQUI 84 to control equipment meeting the requirements of TREA 6 whenever EQUI 84 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 85  A‐MiII 1 BRK Cyclone 

5.83.1  The Permittee shall vent emissions from EQUI 85 to control equipment meeting the requirements of TREA 6 whenever EQUI 85 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 86  A‐MiII 2 BRK Cyclone 

5.84.1  The Permittee shall vent emissions from EQUI 86 to control equipment meeting the requirements of TREA 6 whenever EQUI 86 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 87  A 1 MB Rollstand 

5.85.1  The Permittee shall vent emissions from EQUI 87 to control equipment meeting the requirements of TREA 6  whenever EQUI 87 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 88  A 1 MA Rollstand 

5.86.1  The Permittee shall vent emissions from EQUI 88 to control equipment meeting the requirements of TREA 6 whenever EQUI 88 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 89  A Mill Surge Bin 

5.87.1  The Permittee shall vent emissions from EQUI 89 to control equipment meeting the requirements of TREA 6 whenever EQUI 89 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 90  A 1 BRK Airlock Hopper 

5.88.1  The Permittee shall vent emissions from EQUI 90 to control equipment meeting the requirements of TREA 6 whenever EQUI 90 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 91  A 2 BRK Airlock Hopper 

5.89.1  The Permittee shall vent emissions from EQUI 91 to control equipment meeting the requirements of TREA 6 whenever EQUI 91 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 92  A Flour to Patent Splitter Airlock Hopper 

5.90.1  The Permittee shall vent emissions from EQUI 92 to control equipment meeting the requirements of TREA 6 whenever EQUI 92 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 93  Germ Aspirator Cyclone 

5.91.1  The Permittee shall vent emissions from EQUI 93 to control equipment meeting the requirements of TREA 7 whenever EQUI 93 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 46: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 46 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 94  A‐MiII 5 BRK Sift to BR Dust 1,2,3 (38) Cyclone 

5.92.1  The Permittee shall vent emissions from EQUI 94 to control equipment meeting the requirements of TREA 7 whenever EQUI 94 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 95  A‐Mill Shorts (37) Cyclone 

5.93.1  The Permittee shall vent emissions from EQUI 95 to control equipment meeting the requirements of TREA 7 whenever EQUI 95 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 96  A.MiII 3 LG (34) Cyclone 

5.94.1  The Permittee shall vent emissions from EQUI 96 to control equipment meeting the requirements of TREA 7 whenever EQUI 96 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 97  A‐MiII 2 LG (35) Cyclone 

5.95.1  The Permittee shall vent emissions from EQUI 97 to control equipment meeting the requirements of TREA 7 whenever EQUI 97 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 98  A‐MiII BR‐SH Dust to Sift (36) Cyclone 

5.96.1  The Permittee shall vent emissions from EQUI 98 to control equipment meeting the requirements of TREA 7 whenever EQUI 98 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 99  A‐MiII 2 CLR (50) Cyclone 

5.97.1  The Permittee shall vent emissions from EQUI 99 to control equipment meeting the requirements of TREA 7 whenever EQUI 99 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 100  A‐Mill 2 Mids (16) Cyclone 

5.98.1  The Permittee shall vent emissions from EQUI 100 to control equipment meeting the requirements of TREA 7 whenever EQUI 100 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 101  A‐Mill 2 Mids (17) Cyclone 

5.99.1  The Permittee shall vent emissions from EQUI 101 to control equipment meeting the requirements of TREA 7 whenever EQUI 101 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 102  A‐Mill 2 Mids (18) Cyclone 

5.100.1  The Permittee shall vent emissions from EQUI 102 to control equipment meeting the requirements of TREA 7 whenever EQUI 102 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 103  A‐MiII 5 BRK 2 (19) Cyclone 

5.101.1  The Permittee shall vent emissions from EQUI 103 to control equipment meeting the requirements of TREA 7 whenever EQUI 103 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 104  A‐MiII 5 BRK 1 (20) Cyclone 

5.102.1  The Permittee shall vent emissions from EQUI 104 to control equipment meeting the requirements of 

Page 47: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 47 of 109 

  

 

Requirement number  Requirement and citation TREA 7 whenever EQUI 104 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 105  A‐Mill 3 Mids (21) Cyclone 

5.103.1  The Permittee shall vent emissions from EQUI 105 to control equipment meeting the requirements of TREA 7 whenever EQUI 105 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 106  A‐Mill 3 Mids (22) Cyclone 

5.104.1  The Permittee shall vent emissions from EQUI 106 to control equipment meeting the requirements of TREA 7 whenever EQUI 106 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 107  A‐Mill 6 Mids (25) Cyclone 

5.105.1  The Permittee shall vent emissions from EQUI 107 to control equipment meeting the requirements of TREA 7 whenever EQUI 107 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 108  A‐Mill 4 Mids (23) Cyclone 

5.106.1  The Permittee shall vent emissions from EQUI 108 to control equipment meeting the requirements of TREA 7 whenever EQUI 108 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 109  A‐Mill 5 Mids (24) Cyclone 

5.107.1  The Permittee shall vent emissions from EQUI 109 to control equipment meeting the requirements of TREA 7 whenever EQUI 109 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 110  A‐Mill 1 Tails (26) Cyclone 

5.108.1  The Permittee shall vent emissions from EQUI 110 to control equipment meeting the requirements of TREA 7 whenever EQUI 110 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 111  A‐Mill 2 SIZ (27) Cyclone 

5.109.1  The Permittee shall vent emissions from EQUI 111 to control equipment meeting the requirements of TREA 7 whenever EQUI 111 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 112  A‐Mill 1 Qual (28) Cyclone 

5.110.1  The Permittee shall vent emissions from EQUI 112 to control equipment meeting the requirements of TREA 7 whenever EQUI 112 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 113  A‐Mill Suction (29) Cyclone 

5.111.1  The Permittee shall vent emissions from EQUI 113 to control equipment meeting the requirements of TREA 7 whenever EQUI 113 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 48: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 48 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

EQUI 114  A‐Mill Wht Germ (39) Cyclone 

5.112.1  The Permittee shall vent emissions from EQUI 114 to control equipment meeting the requirements of TREA 7 whenever EQUI 114 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 115  A‐MiII 4 BC (30) Cyclone 

5.113.1  The Permittee shall vent emissions from EQUI 115 to control equipment meeting the requirements of TREA 7 whenever EQUI 115 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 116  A‐Mill 2 Talls (31) Cyclone 

5.114.1  The Permittee shall vent emissions from EQUI 116 to control equipment meeting the requirements of TREA 7 whenever EQUI 116 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 117  A‐Mill 7 Mids (32) Cyclone 

5.115.1  The Permittee shall vent emissions from EQUI 117 to control equipment meeting the requirements of TREA 7 whenever EQUI 117 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 118  A‐MiII 1 LG (33) Cyclone 

5.116.1  The Permittee shall vent emissions from EQUI 118 to control equipment meeting the requirements of TREA 7 whenever EQUI 118 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000] 

EQUI 119  A‐Mill 5 BRK to Roll l Cyclone 

5.117.1  The Permittee shall vent emissions from EQUI 119 to control equipment meeting the requirements of TREA 7 whenever EQUI 119 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 120  A‐Mill 4 BRK to Roll 2 Cyclone 

5.118.1  The Permittee shall vent emissions from EQUI 120 to control equipment meeting the requirements of TREA 7 whenever EQUI 120 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 121  A Cyclone Airlock 41 Hopper 

5.119.1  The Permittee shall vent emissions from EQUI 121 to control equipment meeting the requirements of TREA 7 whenever EQUI 121 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 122  A‐Mill 1 MC to Roll (44) Cyclone 

5.120.1  The Permittee shall vent emissions from EQUI 122 to control equipment meeting the requirements of TREA 7 whenever EQUI 122 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 123  A‐Mill 2 MC to Roll (4s) Cyclone 

Page 49: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 49 of 109 

  

 

Requirement number  Requirement and citation 

5.121.1  The Permittee shall vent emissions from EQUI 123 to control equipment meeting the requirements of TREA 7 whenever EQUI 123 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 124  A‐Mill P4 Purifier (46) Cyclone 

5.122.1  The Permittee shall vent emissions from EQUI 124 to control equipment meeting the requirements of TREA 7 whenever EQUI 124 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 125  A‐Mill P13 (47) Cyclone 

5.123.1  The Permittee shall vent emissions from EQUI 125 to control equipment meeting the requirements of TREA 7 whenever EQUI 125 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 126  A‐Mill P9 (48) Cyclone 

5.124.1  The Permittee shall vent emissions from EQUI 126 to control equipment meeting the requirements of TREA 7 whenever EQUI 126 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 127  A‐Mill Germ/1T (48) Cyclone 

5.125.1  The Permittee shall vent emissions from EQUI 127 to control equipment meeting the requirements of TREA 7 whenever EQUI 127 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 128  A‐Mill 2 SIZ to Roll (53) Cyclone 

5.126.1  The Permittee shall vent emissions from EQUI 128  to control equipment meeting the requirements of TREA 7 whenever EQUI 128 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 129  A‐Mill (50) Cyclone 

5.127.1  The Permittee shall vent emissions from EQUI 129 to control equipment meeting the requirements of TREA 7 whenever EQUI 129 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 130  A‐Mill PAT/CLR (51) Cyclone 

5.128.1  The Permittee shall vent emissions from EQUI 130 to control equipment meeting the requirements of TREA 7 whenever EQUI 130 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 131  A‐Mill 7M to Roll (52) Cyclone 

5.129.1  The Permittee shall vent emissions from EQUI 131 to control equipment meeting the requirements of TREA 7 whenever EQUI 131 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 132  A‐Mill 2T to Roll (54) Cyclone 

5.130.1  The Permittee shall vent emissions from EQUI 132 to control equipment meeting the requirements of 

Page 50: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 50 of 109 

  

 

Requirement number  Requirement and citation TREA 7 whenever EQUI 132 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 133  A Bran Duster 1 

5.131.1  The Permittee shall vent emissions from EQUI 133 to control equipment meeting the requirements of TREA 8 whenever EQUI 133 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 134  A Bran Duster 2 

5.132.1  The Permittee shall vent emissions from EQUI 134 to control equipment meeting the requirements of TREA 8 whenever EQUI 134 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 135  A Bran Duster 3 

5.133.1  The Permittee shall vent emissions from EQUI 135 to control equipment meeting the requirements of TREA 8 whenever EQUI 135 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 136  A P‐18 2/1 CLR Receiving Cyclone 

5.134.1  The Permittee shall vent emissions from EQUI 136 to control equipment meeting the requirements of TREA 8 whenever EQUI 136 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 137  A P4 Purifier 

5.135.1  The Permittee shall vent emissions from EQUI 137 to control equipment meeting the requirements of TREA 8 whenever EQUI 137 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 138  A P9 & P13 Purifier 

5.136.1  The Permittee shall vent emissions from EQUI 138 to control equipment meeting the requirements of TREA 8 whenever EQUI 138 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 139  A Shorts Duster 

5.137.1  The Permittee shall vent emissions from EQUI 139 to control equipment meeting the requirements of TREA 8 whenever EQUI 139 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 140  A Shorts Duster 2 

5.138.1  The Permittee shall vent emissions from EQUI 140 to control equipment meeting the requirements of TREA 8 whenever EQUI 140 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 141  A Patent Scale 

5.139.1  The Permittee shall vent emissions from EQUI 141 to control equipment meeting the requirements of TREA 8 whenever EQUI 141 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 51: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 51 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

EQUI 142  Farina Purifier Airlock Hopper 

5.140.1  The Permittee shall vent emissions from EQUI 142 to control equipment meeting the requirements of TREA 8 whenever EQUI 142 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 143  Germ Final Cyclone 

5.141.1  The Permittee shall vent emissions from EQUI 143 to control equipment meeting the requirements of TREA 8 whenever EQUI 143 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 144  A Bran & Shorts Airlock Hopper 

5.142.1  The Permittee shall vent emissions from EQUI 144 to control equipment meeting the requirements of TREA 8 whenever EQUI 144 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 145  A Red Dog Duster Airlock Hopper 

5.143.1  The Permittee shall vent emissions from EQUI 145 to control equipment meeting the requirements of TREA 8 whenever EQUI 145 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 146  Germ Aspirator Suction Cyclone 

5.144.1  The Permittee shall vent emissions from EQUI 146 to control equipment meeting the requirements of TREA 9 whenever EQUI 146 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 147  A Patent Splitter Cyclone 

5.145.1  The Permittee shall vent emissions from EQUI 147 to control equipment meeting the requirements of TREA 9 whenever EQUI 147 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 148  Filter 14 Suction Air Horizontal Splitter 

5.146.1  The Permittee shall vent emissions from EQUI 148 to control equipment meeting the requirements of TREA 9 whenever EQUI 148 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 149  A P2 Purifier 

5.147.1  The Permittee shall vent emissions from EQUI 149 to control equipment meeting the requirements of TREA 9 whenever EQUI 149 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 150  A P1 Purifier 

5.148.1  The Permittee shall vent emissions from EQUI 150 to control equipment meeting the requirements of TREA 9 whenever EQUI 150 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 52: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 52 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 151  Germ Classifier 

5.149.1  The Permittee shall vent emissions from EQUI 151 to control equipment meeting the requirements of TREA 9 whenever EQUI 151 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 152  Farina Purifier Cyclone 1 

5.150.1  The Permittee shall vent emissions from EQUI 152 to control equipment meeting the requirements of TREA 10 whenever EQUI 152 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 153  Farina Purifier Cyclone 2 

5.151.1  The Permittee shall vent emissions from EQUI 153 to control equipment meeting the requirements of TREA 10 whenever EQUI 153 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 154  B P1 & P2 Purifier 

5.152.1  The Permittee shall vent emissions from EQUI 154 to control equipment meeting the requirements of TREA 10 whenever EQUI 154 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 155  B P7 & P8 Purifier 

5.153.1  The Permittee shall vent emissions from EQUI 155 to control equipment meeting the requirements of TREA 10 whenever EQUI 155 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 156  B P5 & P6 Purifier 

5.154.1  The Permittee shall vent emissions from EQUI 156 to control equipment meeting the requirements of TREA 10 whenever EQUI 156 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 157  B P3 & P4 Purifier 

5.155.1  The Permittee shall vent emissions from EQUI 157 to control equipment meeting the requirements of TREA 10 whenever EQUI 157operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 158  B P1 & P2 Purifier 

5.156.1  The Permittee shall vent emissions from EQUI 158 to control equipment meeting the requirements of TREA 10 whenever EQUI 158 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 159  B Floor Cut In to Mill 

5.157.1  The Permittee shall vent emissions from EQUI 159 to control equipment meeting the requirements of TREA 10 whenever EQUI 159 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 160  B Patent Scale 

Page 53: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 53 of 109 

  

 

Requirement number  Requirement and citation 

5.158.1  The Permittee shall vent emissions from EQUI 160 to control equipment meeting the requirements of TREA 10 whenever EQUI 160 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 161  B Red Dog Airlock Hopper 

5.159.1  The Permittee shall vent emissions from EQUI 161 to control equipment meeting the requirements of TREA 10 whenever EQUI 161 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 162  B Clear to Bin Airlock Hopper 

5.160.1  The Permittee shall vent emissions from EQUI 162 to control equipment meeting the requirements of TREA 10 whenever EQUI 162 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 163  B Patent to Sifter Airlock Hopper 

5.161.1  The Permittee shall vent emissions from EQUI 163 to control equipment meeting the requirements of TREA 10 whenever EQUI 163 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 164  B 2nd BRK Rollstand 

5.162.1  The Permittee shall vent emissions from EQUI 164 to control equipment meeting the requirements of TREA 10 whenever EQUI 164 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 165  B Patent to Bin Airlock Hopper 

5.163.1  The Permittee shall vent emissions from EQUI 165 to control equipment meeting the requirements of TREA 10 whenever EQUI 165 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 166  B Patent 3 Way Splitter Cyclone 

5.164.1  The Permittee shall vent emissions from EQUI 166 to control equipment meeting the requirements of TREA 10 whenever EQUI 166 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 167  B Patent Flour Cyclone 

5.165.1  The Permittee shall vent emissions from EQUI 167 to control equipment meeting the requirements of TREA 10 whenever EQUI 167 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 168  B 3 BRK F (5) Cyclone 

5.166.1  The Permittee shall vent emissions from EQUI 168 to control equipment meeting the requirements of TREA 11 whenever EQUI 168 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 169  B 3 BRK 1 (7) Cyclone 

5.167.1  The Permittee shall vent emissions from EQUI 169 to control equipment meeting the requirements of 

Page 54: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 54 of 109 

  

 

Requirement number  Requirement and citation TREA 11 whenever EQUI 169 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 170  B BRK Cuts (9) Cyclone 

5.168.1  The Permittee shall vent emissions from EQUI 170 to control equipment meeting the requirements of TREA 11 whenever EQUI 170 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 171  B 1 MF (11) Cyclone 

5.169.1  The Permittee shall vent emissions from EQUI 171 to control equipment meeting the requirements of TREA 11 whenever EQUI 171 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 172  B 2 Mids (13) Cyclone 

5.170.1  The Permittee shall vent emissions from EQUI 172 to control equipment meeting the requirements of TREA 11 whenever EQUI 172 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 173  B 2 BRK 3 (2) Cyclone 

5.171.1  The Permittee shall vent emissions from EQUI 173 to control equipment meeting the requirements of TREA 11 whenever EQUI 173 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 174  B 2 BRK 2 (3) Cyclone 

5.172.1  The Permittee shall vent emissions from EQUI 174 to control equipment meeting the requirements of TREA 11 whenever EQUI 174 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 175  B 2 BRK 1 (4) Cyclone 

5.173.1  The Permittee shall vent emissions from EQUI 175 to control equipment meeting the requirements of TREA 11 whenever EQUI 175 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 176  B 3 BRK F (6) Cyclone 

5.174.1  The Permittee shall vent emissions from EQUI 176 to control equipment meeting the requirements of TREA 11 whenever EQUI 176 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 177  B 3 BRK 2 (8) Cyclone 

5.175.1  The Permittee shall vent emissions from EQUI 177 to control equipment meeting the requirements of TREA 11 whenever EQUI 177 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 178  B C SIZ (12) Cyclone 

5.176.1  The Permittee shall vent emissions from EQUI 178 to control equipment meeting the requirements of TREA 11 whenever EQUI 178 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 55: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 55 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

EQUI 179  B 1 MC (14) Cyclone 

5.177.1  The Permittee shall vent emissions from EQUI 179 to control equipment meeting the requirements of TREA 11 whenever EQUI 179 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 180  B 1T (21) Cyclone 

5.178.1  The Permittee shall vent emissions from EQUI 180 to control equipment meeting the requirements of TREA 11 whenever EQUI 180 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 181  B 5M Cyclone 

5.179.1  The Permittee shall vent emissions from EQUI 181 to control equipment meeting the requirements of TREA 11 whenever EQUI 181 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 182  B 3M (18) Cyclone 

5.180.1  The Permittee shall vent emissions from EQUI 182 to control equipment meeting the requirements of TREA 11 whenever EQUI 182 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 183  B 4M (20) Cyclone 

5.181.1  The Permittee shall vent emissions from EQUI 183 to control equipment meeting the requirements of TREA 11 whenever EQUI 183 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 184  B 5 BRK 1 (24) Cyclone 

5.182.1  The Permittee shall vent emissions from EQUI 184 to control equipment meeting the requirements of TREA 11 whenever EQUI 184 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 185  B 5 BRK 2 (25) Cyclone 

5.183.1  The Permittee shall vent emissions from EQUI 185 to control equipment meeting the requirements of TREA 11 whenever EQUI 185 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 186  B Pur Filt to 2T SIFT (28) Cyclone 

5.184.1  The Permittee shall vent emissions from EQUI 186 to control equipment meeting the requirements of TREA 11 whenever EQUI 186 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 187  B 2T (30) Cyclone 

5.185.1  The Permittee shall vent emissions from EQUI 187 to control equipment meeting the requirements of TREA 11 whenever EQUI 187 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 56: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 56 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 188  B 2M (15) Cyclone 

5.186.1  The Permittee shall vent emissions from EQUI 188 to control equipment meeting the requirements of TREA 11 whenever EQUI 188 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 189  B Qual (17) Cyclone 

5.187.1  The Permittee shall vent emissions from EQUI 189 to control equipment meeting the requirements of TREA 11 whenever EQUI 189 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 190  B 5M (16) Cyclone 

5.188.1  The Permittee shall vent emissions from EQUI 190 to control equipment meeting the requirements of TREA 11 whenever EQUI 190 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 191  B F SIZ (10) Cyclone 

5.189.1  The Permittee shall vent emissions from EQUI 191 to control equipment meeting the requirements of TREA 11 whenever EQUI 191 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 192  B 4 BRK Dust Sift (23) Cyclone 

5.190.1  The Permittee shall vent emissions from EQUI 192 to control equipment meeting the requirements of TREA 11 whenever EQUI 192 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 193  B 4 BRK 2 (26) Cyclone 

5.191.1  The Permittee shall vent emissions from EQUI 193 to control equipment meeting the requirements of TREA 11 whenever EQUI 193 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 194  B 4 BRK 1 (27) Cyclone 

5.192.1  The Permittee shall vent emissions from EQUI 194 to control equipment meeting the requirements of TREA 11 whenever EQUI 194 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 195  B 1 LG (29) Cyclone 

5.193.1  The Permittee shall vent emissions from EQUI 195 to control equipment meeting the requirements of TREA 11 whenever EQUI 195 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 196  B 2 LG (31) Cyclone 

5.194.1  The Permittee shall vent emissions from EQUI 196 to control equipment meeting the requirements of TREA 11 whenever EQUI 196 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 197  B 7M (32) Cyclone 

Page 57: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 57 of 109 

  

 

Requirement number  Requirement and citation 

5.195.1  The Permittee shall vent emissions from EQUI 197 to control equipment meeting the requirements of TREA 11 whenever EQUI 197 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 198  B 6M (33) Cyclone 

5.196.1  The Permittee shall vent emissions from EQUI 198 to control equipment meeting the requirements of TREA 11 whenever EQUI 198 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 199  B (34) Cyclone 

5.197.1  The Permittee shall vent emissions from EQUI 199 to control equipment meeting the requirements of TREA 11 whenever EQUI 199 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 200  C P3 & P4 Purifiers 

5.198.1  The Permittee shall vent emissions from EQUI 200 to control equipment meeting the requirements of TREA 12 whenever EQUI 200 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 201  C P1 & P5 Purifiers 

5.199.1  The Permittee shall vent emissions from EQUI 201 to control equipment meeting the requirements of TREA 12 whenever EQUI 201 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 202  C P1 & P2 Farina Purifiers 

5.200.1  The Permittee shall vent emissions from EQUI 202 to control equipment meeting the requirements of TREA 12 whenever EQUI 202 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 203  C Mill Pneumatic Vibrator Hopper 

5.201.1  The Permittee shall vent emissions from EQUI 203 to control equipment meeting the requirements of TREA 12 whenever EQUI 203 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 204  C 3/4 1 Rollstand 

5.202.1  The Permittee shall vent emissions from EQUI 204 to control equipment meeting the requirements of TREA 12 whenever EQUI 204 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 205  C Bran Rollstand 

5.203.1  The Permittee shall vent emissions from EQUI 205 to control equipment meeting the requirements of TREA 12 whenever EQUI 205 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 206  C 4/5 BRC Feed Conveyor 

5.204.1  The Permittee shall vent emissions from EQUI 206 to control equipment meeting the requirements of 

Page 58: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 58 of 109 

  

 

Requirement number  Requirement and citation TREA 12 whenever EQUI 206 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 207  C 4/5 BKC Rollstand 

5.205.1  The Permittee shall vent emissions from EQUI 207 to control equipment meeting the requirements of TREA 12 whenever EQUI 207 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 208  C 1/2 MC 1 Rollstand 

5.206.1  The Permittee shall vent emissions from EQUI 208 to control equipment meeting the requirements of TREA 12 whenever EQUI 208 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 209  C 3 BK 2 Rollstand 

5.207.1  The Permittee shall vent emissions from EQUI 209 to control equipment meeting the requirements of TREA 12 whenever EQUI 209 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 210  C FL 3 CLR to Bin Airlock Hopper 

5.208.1  The Permittee shall vent emissions from EQUI 210 to control equipment meeting the requirements of TREA 12 whenever EQUI 210 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 211  C FL 1 Patent to Bin Airlock Bench Hopper 

5.209.1  The Permittee shall vent emissions from EQUI 211 to control equipment meeting the requirements of TREA 12 whenever EQUI 211 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 212  C Feed to B CH Airlock Hopper 

5.210.1  The Permittee shall vent emissions from EQUI 212 to control equipment meeting the requirements of TREA 12 whenever EQUI 212 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 213  C FL 2 to RBLT Airlock Hopper 

5.211.1  The Permittee shall vent emissions from EQUI 213 to control equipment meeting the requirements of TREA 12 whenever EQUI 213 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 214  C FL 1 to RBLT Airlock Hopper 

5.212.1  The Permittee shall vent emissions from EQUI 214 to control equipment meeting the requirements of TREA 12 whenever EQUI 214 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 215  C FL 1 to RBLT Cyclone 

5.213.1  The Permittee shall vent emissions from EQUI 215 to control equipment meeting the requirements of TREA 12 whenever EQUI 215 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 59: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 59 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

EQUI 216  C FL 2 to RBLT Cyclone 

5.214.1  The Permittee shall vent emissions from EQUI 216 to control equipment meeting the requirements of TREA 12 whenever EQUI 216 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 217  C Feed to RBLT Cyclone 

5.215.1  The Permittee shall vent emissions from EQUI 217 to control equipment meeting the requirements of TREA 13 whenever EQUI 217 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 218  C FL 3 to RBLT Cyclone 

5.216.1  The Permittee shall vent emissions from EQUI 218 to control equipment meeting the requirements of TREA 13 whenever EQUI 218 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 219  C 1/2 BK 1&2 (2) Cyclone 

5.217.1  The Permittee shall vent emissions from EQUI 219 to control equipment meeting the requirements of TREA 13 whenever EQUI 219 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 220  C 1/2 BK 1 (3) Cyclone 

5.218.1  The Permittee shall vent emissions from EQUI 220 to control equipment meeting the requirements of TREA 13 whenever EQUI 220 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 221  C 1/2 BK 2 Cyclone 

5.219.1  The Permittee shall vent emissions from EQUI 221 to control equipment meeting the requirements of TREA 13 whenever EQUI 221 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 222  C GR 3 (23) Cyclone 

5.220.1  The Permittee shall vent emissions from EQUI 222 to control equipment meeting the requirements of TREA 13 whenever EQUI 222 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 223  C GR 1/22 (22) Cyclone 

5.221.1  The Permittee shall vent emissions from EQUI 223 to control equipment meeting the requirements of TREA 13 whenever EQUI 223 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 224  C Bran Relift Cyclone 

5.222.1  The Permittee shall vent emissions from EQUI 224 to control equipment meeting the requirements of TREA 13 whenever EQUI 224 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 60: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 60 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 225  C 3 BK 1 (9) Cyclone 

5.223.1  The Permittee shall vent emissions from EQUI 225 to control equipment meeting the requirements of TREA 13 whenever EQUI 225 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 226  C 3 BKC 2 (13) Cyclone 

5.224.1  The Permittee shall vent emissions from EQUI 226 to control equipment meeting the requirements of TREA 13 whenever EQUI 226 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 227  C Bran Dust 2 (15) Cyclone 

5.225.1  The Permittee shall vent emissions from EQUI 227 to control equipment meeting the requirements of TREA 13 whenever EQUI 227 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 228  C 3/4 M (16) Cyclone 

5.226.1  The Permittee shall vent emissions from EQUI 228 to control equipment meeting the requirements of TREA 13 whenever EQUI 228 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 229  C 5/6 Mids (18) Cyclone 

5.227.1  The Permittee shall vent emissions from EQUI 229 to control equipment meeting the requirements of TREA 13 whenever EQUI 229 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 230  C B SIZ (1) Cyclone 

5.228.1  The Permittee shall vent emissions from EQUI 230 to control equipment meeting the requirements of TREA 13 whenever EQUI 230 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 231  C A SIZ (4) Cyclone 

5.229.1  The Permittee shall vent emissions from EQUI 231 to control equipment meeting the requirements of TREA 13 whenever EQUI 231 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 232  C 1/2 MC 1 (6) Cyclone 

5.230.1  The Permittee shall vent emissions from EQUI 232 to control equipment meeting the requirements of TREA 13 whenever EQUI 232 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 233  C 1/2 MC 2 (7) Cyclone 

5.231.1  The Permittee shall vent emissions from EQUI 233 to control equipment meeting the requirements of TREA 13 whenever EQUI 233 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 234  C 1/2 MF (8) Cyclone 

Page 61: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 61 of 109 

  

 

Requirement number  Requirement and citation 

5.232.1  The Permittee shall vent emissions from EQUI 234 to control equipment meeting the requirements of TREA 13 whenever EQUI 234 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 235  C Qual (10) Cyclone 

5.233.1  The Permittee shall vent emissions from EQUI 235 to control equipment meeting the requirements of TREA 13 whenever EQUI 235 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 236  C Filter Dust (11) Cyclone 

5.234.1  The Permittee shall vent emissions from EQUI 236 to control equipment meeting the requirements of TREA 13 whenever EQUI 236 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 237  C Bran Dust 1 (12) Cyclone 

5.235.1  The Permittee shall vent emissions from EQUI 237 to control equipment meeting the requirements of TREA 13 whenever EQUI 237 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 238  C 4/5 BKC (14) Cyclone 

5.236.1  The Permittee shall vent emissions from EQUI 238 to control equipment meeting the requirements of TREA 13 whenever EQUI 238 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 239  C 4/5 BKF (17) Cyclone 

5.237.1  The Permittee shall vent emissions from EQUI 239 to control equipment meeting the requirements of TREA 13 whenever EQUI 239 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 240  C 1 TAIL (19) Cyclone 

5.238.1  The Permittee shall vent emissions from EQUI 240 to control equipment meeting the requirements of TREA 13 whenever EQUI 240 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 241  C 1/2 LG (20) Cyclone 

5.239.1  The Permittee shall vent emissions from EQUI 241 to control equipment meeting the requirements of TREA 13 whenever EQUI 241 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 242  C 7/8 M (21) Cyclone 

5.240.1  The Permittee shall vent emissions from EQUI 242 to control equipment meeting the requirements of TREA 13 whenever EQUI 242 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 243  L/O System 1 Collection Airlock Hopper 

5.241.1  The Permittee shall vent emissions from EQUI 243 to control equipment meeting the requirements of 

Page 62: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 62 of 109 

  

 

Requirement number  Requirement and citation TREA 14 whenever EQUI 243 operates. [Title I Condition: Avoid major source under 40 CFR 52, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000] 

EQUI 244  L/O System 2 Collection Airlock Hopper 

5.242.1  The Permittee shall vent emissions from EQUI 244 to control equipment meeting the requirements of TREA 14 whenever EQUI 244 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 245  L/O System 3 Collection Airlock Hopper 

5.243.1  The Permittee shall vent emissions from EQUI 245 to control equipment meeting the requirements of TREA 14 whenever EQUI 245 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 246  L/O Filter 17 Discharge Airlock Hopper 

5.244.1  The Permittee shall vent emissions from EQUI 246 to control equipment meeting the requirements of TREA 14 whenever EQUI 246 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 247  L/O Germ Collection Airlock Hopper 

5.245.1  The Permittee shall vent emissions from EQUI 247 to control equipment meeting the requirements of TREA 14 whenever EQUI 247 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 248  A Track Aspiration 1 

5.246.1  The Permittee shall vent emissions from EQUI 248 to control equipment meeting the requirements of TREA 14 whenever EQUI 248 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 249  A Track Aspiration 1 

5.247.1  The Permittee shall vent emissions from EQUI 249 to control equipment meeting the requirements of TREA 14 whenever EQUI 249 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 250  A Track Aspiration 1 

5.248.1  The Permittee shall vent emissions from EQUI 250 to control equipment meeting the requirements of TREA 14 whenever EQUI 250 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 251  A Track Aspiration 1 

5.249.1  The Permittee shall vent emissions from EQUI 251 to control equipment meeting the requirements of TREA 14 whenever EQUI 251 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 252  L/O System 1 Flour Collection Conveyor 

5.250.1  The Permittee shall vent emissions from EQUI 252 to control equipment meeting the requirements of TREA 14 whenever EQUI 252 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 63: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 63 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 253  L/O System 2 Flour Collection Conveyor 

5.251.1  The Permittee shall vent emissions from EQUI 253 to control equipment meeting the requirements of TREA 14 whenever EQUI 253 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 254  L/O System 3 Flour Collection Conveyor 

5.252.1  The Permittee shall vent emissions from EQUI 254 to control equipment meeting the requirements of TREA 14 whenever EQUI 254 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 255  Farina Collection Cyclone 

5.253.1  The Permittee shall vent emissions from EQUI 255 to control equipment meeting the requirements of TREA 14 whenever EQUI 255 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 256  L/O Truck Transfer Cyclone 

5.254.1  The Permittee shall vent emissions from EQUI 256 to control equipment meeting the requirements of TREA 14 whenever EQUI 256 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 257  L/O System 1 Cyclone 

5.255.1  The Permittee shall vent emissions from EQUI 257 to control equipment meeting the requirements of TREA 15 whenever EQUI 257 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 258  L/O System 2 Cyclone 

5.256.1  The Permittee shall vent emissions from EQUI 258 to control equipment meeting the requirements of TREA 15 whenever EQUI 258 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 259  L/O System 3 Cyclone 

5.257.1  The Permittee shall vent emissions from EQUI 259 to control equipment meeting the requirements of TREA 15 whenever EQUI 259 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 260  Flour Storage Bin 1 

5.258.1  The Permittee shall vent emissions from EQUI 260 to control equipment meeting the requirements of TREA 15 whenever EQUI 260 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 261  Flour Storage Bin 2 

5.259.1  The Permittee shall vent emissions from EQUI 261 to control equipment meeting the requirements of TREA 15 whenever EQUI 261 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 262  Flour Storage Bin 3 

Page 64: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 64 of 109 

  

 

Requirement number  Requirement and citation 

5.260.1  The Permittee shall vent emissions from EQUI 262 to control equipment meeting the requirements of TREA 15 whenever EQUI 262 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 263  Flour Storage Bin 4 

5.261.1  The Permittee shall vent emissions from EQUI 263 to control equipment meeting the requirements of TREA 15 whenever EQUI 263 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 264  Flour Storage Bin 5 

5.262.1  The Permittee shall vent emissions from EQUI 264 to control equipment meeting the requirements of TREA 15 whenever EQUI 264 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 265  Flour Storage Bin 6 

5.263.1  The Permittee shall vent emissions from EQUI 265 to control equipment meeting the requirements of TREA 15 whenever EQUI 265 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 266  Flour Storage Bin 7 

5.264.1  The Permittee shall vent emissions from EQUI 266 to control equipment meeting the requirements of TREA 15 whenever EQUI 266 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 267  Flour Storage Bin 8 

5.265.1  The Permittee shall vent emissions from EQUI 267 to control equipment meeting the requirements of TREA 15 whenever EQUI 267 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 268  Flour Storage Bin 9 

5.266.1  The Permittee shall vent emissions from EQUI 268 to control equipment meeting the requirements of TREA 15 whenever EQUI 268 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 269  Flour Storage Bin 10 

5.267.1  The Permittee shall vent emissions from EQUI 269 to control equipment meeting the requirements of TREA 15 whenever EQUI 269 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 270  C Patent Flour Conveyor Cyclone 

5.268.1  The Permittee shall vent emissions from EQUI 270 to control equipment meeting the requirements of TREA 15 whenever EQUI 270 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 271  A Patent Flour Conveyor Cyclone 

5.269.1  The Permittee shall vent emissions from EQUI 271 to control equipment meeting the requirements of 

Page 65: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 65 of 109 

  

 

Requirement number  Requirement and citation TREA 15 whenever EQUI 271 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 272  Farina Final Product Sifter Cyclone 

5.270.1  The Permittee shall vent emissions from EQUI 272 to control equipment meeting the requirements of TREA 15 whenever EQUI 272 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 273  Flour Storage Bin 11 

5.271.1  The Permittee shall vent emissions from EQUI 273 to control equipment meeting the requirements of TREA 15 whenever EQUI 273 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 274  Flour Storage Bin 12 

5.272.1  The Permittee shall vent emissions from EQUI 274 to control equipment meeting the requirements of TREA 15 whenever EQUI 274 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 275  Flour Storage Bin 13 

5.273.1  The Permittee shall vent emissions from EQUI 275 to control equipment meeting the requirements of TREA 15 whenever EQUI 275 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 276  Flour Storage Bin 14 

5.274.1  The Permittee shall vent emissions from EQUI 276 to control equipment meeting the requirements of TREA 15 whenever EQUI 276 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 277  Flour Storage Bin 15 

5.275.1  The Permittee shall vent emissions from EQUI 277 to control equipment meeting the requirements of TREA 15 whenever EQUI 277 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 278  Flour Storage Bin 16 

5.276.1  The Permittee shall vent emissions from EQUI 278 to control equipment meeting the requirements of TREA 15 whenever EQUI 278 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 279  Flour Storage Bin 17 

5.277.1  The Permittee shall vent emissions from EQUI 279 to control equipment meeting the requirements of TREA 15 whenever EQUI 279 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 280  Flour Storage Bin 18 

5.278.1  The Permittee shall vent emissions from EQUI 280 to control equipment meeting the requirements of TREA 15 whenever EQUI 280 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 66: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 66 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

EQUI 281  Flour Storage Bin 19 

5.279.1  The Permittee shall vent emissions from EQUI 281 to control equipment meeting the requirements of TREA 15 whenever EQUI 281 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 282  Flour Storage Bin 20 

5.280.1  The Permittee shall vent emissions from EQUI 282 to control equipment meeting the requirements of TREA 15 whenever EQUI 282 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 283  Off Flour Bin 

5.281.1  The Permittee shall vent emissions from EQUI 283 to control equipment meeting the requirements of TREA 15 whenever EQUI 283 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 284  Final Product Garner Scale System 1 

5.282.1  The Permittee shall vent emissions from EQUI 284 to control equipment meeting the requirements of TREA 15 whenever EQUI 284 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 285  Final Product Garner Scale System 2 

5.283.1  The Permittee shall vent emissions from EQUI 285 to control equipment meeting the requirements of TREA 15 whenever EQUI 285 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 286  Final Product Garner Scale System 3 

5.284.1  The Permittee shall vent emissions from EQUI 286 to control equipment meeting the requirements of TREA 15 whenever EQUI 286 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 287  Truck L/O Bin 1 

5.285.1  The Permittee shall vent emissions from EQUI 287 to control equipment meeting the requirements of TREA 16 whenever EQUI 287 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 288  Truck L/O Bin 2 

5.286.1  The Permittee shall vent emissions from EQUI 288 to control equipment meeting the requirements of TREA 16 whenever EQUI 288 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 289  Truck L/O Bin 3 

5.287.1  The Permittee shall vent emissions from EQUI 289 to control equipment meeting the requirements of TREA 16 whenever EQUI 289 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 67: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 67 of 109 

  

 

Requirement number  Requirement and citation 

EQUI 290  Truck L/O Bin 4 

5.288.1  The Permittee shall vent emissions from EQUI 290 to control equipment meeting the requirements of TREA 16 whenever EQUI 290 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 291  Truck L/O Bin 5 

5.289.1  The Permittee shall vent emissions from EQUI 291 to control equipment meeting the requirements of TREA 16 whenever EQUI 291 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 292  Truck L/O Bin 6 

5.290.1  The Permittee shall vent emissions from EQUI 292 to control equipment meeting the requirements of TREA 16 whenever EQUI 292 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 293  Truck L/O Bin 7 

5.291.1  The Permittee shall vent emissions from EQUI 293 to control equipment meeting the requirements of TREA 16 whenever EQUI 293 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 294  Truck L/O Bin 8 

5.292.1  The Permittee shall vent emissions from EQUI 294 to control equipment meeting the requirements of TREA 16 whenever EQUI 294 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 305  Boiler 

5.293.1  Particulate Matter <= 0.4 pounds per million Btu heat input. The potential to emit from the unit is 0.0077 lb/MMBtu due to equipment design and allowable fuels. [Minn. R. 7011.0515, subp. 1] 

5.293.2  Opacity <= 20 percent opacity except for one six‐minute period per hour of not more than 60 percent opacity. [Minn. R. 7011.0515, subp. 2] 

5.293.3  Fuel type: Limited to natural gas and propane only. [Minn. R. 7005.0100, subp. 35a] 

EQUI 306  Hoffman Vacuum A 

5.294.1  The Permittee shall vent emissions from EQUI 306 to control equipment meeting the requirements of TREA 17 whenever EQUI 306 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

EQUI 307  Hoffman Vacuum B 

5.295.1  The Permittee shall vent emissions from EQUI 307 to control equipment meeting the requirements of TREA 18 whenever EQUI 307 operates. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

FUGI 4  Fugitive HAP Sources (Fumigation, Preservation, etc.) 

5.296.1  The Permittee shall limit emissions of HAPs ‐ Total <= 20 tons per year 12‐month rolling sum to be calculated by the 15th day of each month for the previous 12‐month period.   HAP contents for each HAP‐containing material shall be determined as described under the Material 

Page 68: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 68 of 109 

  

 

Requirement number  Requirement and citation Content requirement in this permit. [Title I Condition: Avoid major source under 40 CFR 63.2, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.296.2  The Permittee shall limit emissions of HAPs ‐ Single <= 9.0 tons per year 12‐month rolling sum to be calculated by the 15th day of each month for the previous 12‐month period.   HAP contents for each HAP‐containing material shall be determined as described under the Material Content requirement in this permit. [Title I Condition: Avoid major source under 40 CFR 63.2, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.296.3  Monthly Recordkeeping. By the 15th of the month, the Permittee shall calculate, record, and maintain a record of the total quantity of all HAP‐containing material used at the facility. This shall be based on purchase and usage records. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 63.2, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.296.4  HAPs: Monthly Recordkeeping. By the 15th of the month, the Permittee shall calculate and record the following using the formulas specified in this permit: 1) The total of each HAP‐containing material used in the previous calendar month using the daily usage records. This record shall also include the individual and total HAP contents of each HAP‐containing material used in the previous month, as determined by the Material Content requirement of this permit; 2) The total and individual HAP emissions for the previous month using the formulas specified in this permit; and 3) The 12‐month rolling sum total and individual HAP emissions for the previous 12‐month period by summing the monthly emissions data for the previous 12 months. [Minn. R. 7007.0800, subps. 4‐5] 

5.296.5  HAPs: Monthly Calculation ‐‐ HAP Emissions. The Permittee shall calculate each individual HAP and total HAP emissions using the following equation: HAP Emissions (tons/month) = H   H = (A1 x B1) + (A2 x B2) + (A3 x B3) + ....  Where: H = the amount of each pollutant (either total HAP or each individual HAP), used, in tons/month. A# = amount of each HAP‐containing material used in the previous month, in tons/month. B# = weight percent of each individual or total HAP in A#, as a fraction (e.g., 50% is 0.50). [Minn. R. 7007.0800, subps. 4‐5] 

5.296.6  Material Content.  HAP contents in  materials shall be determined by the Safety Data Sheet (SDS) or the Material Safety Data Sheet (MSDS) provided by the supplier for each material used. If a material content range is given on the SDS or the MSDS, the highest number in the range shall be used in all compliance calculations. If  information is provided in the Regulatory Section of the SDS, the highest number in the range of that section may be used.  Other alternative methods approved by the MPCA may be used to determine the  HAP contents. The Commissioner reserves the right to require the Permittee to determine the HAP contents of any material, according to EPA or ASTM reference methods.  If an EPA or ASTM reference method is used for material content determination, the data obtained shall supersede the SDS or the MSDS. [Minn. R. 7007.0800, subps. 4‐5] 

STRU 6  Filter 11 A‐Mill Pneumatics Stack Vent 

5.297.1  The Permittee shall limit emissions of PM < 10 micron <= 1.66 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.297.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.41 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 7  Filter 12 A‐Mill Pneumatics Stack Vent 

Page 69: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 69 of 109 

  

 

Requirement number  Requirement and citation 

5.298.1  The Permittee shall limit emissions of PM < 10 micron <= 1.66 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.298.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.41 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 8  Filter 13 A Mill Purifiers Stack Vent 

5.299.1  The Permittee shall limit emissions of PM < 10 micron <= 1.77 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.299.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.50 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 9  Filter 14 A Mill Purifiers Stack Vent 

5.300.1  The Permittee shall limit emissions of PM < 10 micron <= 1.46 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.300.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.24 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 10  Filter 15 B Mill Purifiers Stack Vent 

5.301.1  The Permittee shall limit emissions of PM < 10 micron <= 1.48 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.301.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.26 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 11  Filter 16 B Mill Pneumatics Stack Vent 

5.302.1  The Permittee shall limit emissions of PM < 10 micron <= 2.88 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.302.2  The Permittee shall limit emissions of PM < 2.5 micron <= 2.45 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 12  Filter 24 C Mill Purifiers Stack Vent 

5.303.1  The Permittee shall limit emissions of PM < 10 micron <= 2.26 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.303.2  The Permittee shall limit emissions of PM < 2.5 micron <= 1.92 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 13  Filter 26 C Mill Pneumatics Stack Vent 

5.304.1  The Permittee shall limit emissions of PM < 10 micron <= 2.93 pounds per hour 3‐hour average. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.304.2  The Permittee shall limit emissions of PM < 2.5 micron <= 2.49 pounds per hour 3‐hour average. [Title 

Page 70: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 70 of 109 

  

 

Requirement number  Requirement and citation I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

TREA 1  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.305.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.305.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.6  The Permittee shall vent emissions from to TREA 1 whenever EQUI 2 operates, and operate and maintain TREA 1 at all times that any emissions are vented to TREA 1. The Permittee shall document periods of non‐operation of the control equipment TREA 1 whenever EQUI 2 is operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.7  If the Permittee replaces TREA 1, the replacement control must meet or exceed the control efficiency requirements of TREA 1 as well as comply with all other requirements of TREA 1. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.305.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 1 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 

Page 71: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 71 of 109 

  

 

Requirement number  Requirement and citation 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.305.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.305.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.305.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.305.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 2  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.306.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.306.2  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.5  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change. 

Page 72: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 72 of 109 

  

 

Requirement number  Requirement and citation  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.6  The Permittee shall vent emissions from EQUIs 3, 4, 6‐12, and 15‐19 to TREA 2 whenever EQUIs 3, 4, 6‐12, and 15‐19 operate, and operate and maintain TREA 2 at all times that any emissions are vented to TREA 2. The Permittee shall document periods of non‐operation of the control equipment TREA 2 whenever EQUIs 3, 4, 6‐12, and 15‐19 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.7  If the Permittee replaces TREA 2, the replacement control must meet or exceed the control efficiency requirements of TREA 2 as well as comply with all other requirements of TREA 2. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.306.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 2 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.306.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.306.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. 

Page 73: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 73 of 109 

  

 

Requirement number  Requirement and citation [Minn. R. 7007.0800, subp. 4] 

5.306.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.306.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 3  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.307.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.307.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.6  The Permittee shall vent emissions from EQUIs 20‐33 to TREA 3 whenever EQUIs 20‐33 operate, and operate and maintain TREA 3 at all times that any emissions are vented to TREA 3. The Permittee shall document periods of non‐operation of the control equipment TREA 3 whenever EQUIs 20‐33 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.7  If the Permittee replaces TREA 3, the replacement control must meet or exceed the control efficiency requirements of TREA 3 as well as comply with all other requirements of TREA 3 Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 74: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 74 of 109 

  

 

Requirement number  Requirement and citation 

5.307.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.307.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 3 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.307.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.307.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.307.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.307.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 4  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.308.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.308.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major 

Page 75: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 75 of 109 

  

 

Requirement number  Requirement and citation source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.6  The Permittee shall vent emissions from EQUIs 34‐41 and 43‐45 to TREA 4 whenever EQUIs 34‐41 and 43‐45 operates, and operate and maintain TREA 4 at all times that any emissions are vented to EQUIs 34‐41 and 43‐45. The Permittee shall document periods of non‐operation of the control equipment TREA 4 whenever EQUIs 34‐41 and 43‐45 is operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.7  If the Permittee replaces TREA 4, the replacement control must meet or exceed the control efficiency requirements of TREA 4 as well as comply with all other requirements of TREA 4. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.308.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 4 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.308.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as 

Page 76: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 76 of 109 

  

 

Requirement number  Requirement and citation applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.308.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.308.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.308.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 5  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.309.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.309.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.6  The Permittee shall vent emissions from EQUIs 46‐58 and 60‐66 to TREA 5 whenever EQUIs 46‐58 and 60‐66 operate, and operate and maintain TREA 5 at all times that any emissions are vented to TREA 5. The Permittee shall document periods of non‐operation of the control equipment TREA 5 whenever EQUIs 46‐58 and 60‐66 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.7  If the Permittee replaces TREA 5, the replacement control must meet or exceed the control efficiency 

Page 77: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 77 of 109 

  

 

Requirement number  Requirement and citation requirements of TREA 5 as well as comply with all other requirements of TREA 5. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.309.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 5 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.309.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.309.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.309.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.309.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 6  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.310.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.310.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon 

Page 78: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 78 of 109 

  

 

Requirement number  Requirement and citation receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.6  The Permittee shall vent emissions from EQUIs 67‐92 to TREA 6 whenever EQUIs 67‐92 operate, and operate and maintain TREA 6 at all times that any emissions are vented to EQUIs 67‐92. The Permittee shall document periods of non‐operation of the control equipment TREA 6 whenever EQUIs 67‐92 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.7  If the Permittee replaces TREA 6, the replacement control must meet or exceed the control efficiency requirements of TREA 6 as well as comply with all other requirements of TREA 6. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.310.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 6 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.310.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 79: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 79 of 109 

  

 

Requirement number  Requirement and citation 

5.310.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.310.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.310.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.310.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 7  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.311.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.311.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 80: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 80 of 109 

  

 

Requirement number  Requirement and citation 

5.311.6  The Permittee shall vent emissions from EQUIs 93‐132 to TREA 7 whenever EQUIs 93‐132 operates, and operate and maintain TREA 7 at all times that any emissions are vented to TREA 7. The Permittee shall document periods of non‐operation of the control equipment TREA 7 whenever EQUIs 93‐132 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.7  If the Permittee replaces TREA 7, the replacement control must meet or exceed the control efficiency requirements of TREA 7 as well as comply with all other requirements of TREA 7. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.311.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 7 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.311.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.311.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.311.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.311.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. 

Page 81: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 81 of 109 

  

 

Requirement number  Requirement and citation R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 8  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.312.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.312.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.6  The Permittee shall vent emissions from EQUIs 133‐145 to TREA 8 whenever EQUIs 133‐145 operate, and operate and maintain TREA 8 at all times that any emissions are vented to TREA 8. The Permittee shall document periods of non‐operation of the control equipment TREA 8 whenever EQUIs 133‐145 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.7  If the Permittee replaces TREA 8, the replacement control must meet or exceed the control efficiency requirements of TREA 8 as well as comply with all other requirements of TREA 8. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.312.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 8 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 82: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 82 of 109 

  

 

Requirement number  Requirement and citation 

5.312.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.312.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.312.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.312.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.312.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 9  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.313.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.313.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 83: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 83 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

5.313.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.6  The Permittee shall vent emissions from EQUIs 146‐151 to TREA 9 whenever EQUIs 146‐151 operates, and operate and maintain TREA 9 at all times that any emissions are vented to TREA 9. The Permittee shall document periods of non‐operation of the control equipment TREA 9 whenever EQUIs 146‐151 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.7  If the Permittee replaces TREA 9, the replacement control must meet or exceed the control efficiency requirements of TREA 9 as well as comply with all other requirements of TREA 9. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.313.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 9 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.313.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.313.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.313.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and 

Page 84: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 84 of 109 

  

 

Requirement number  Requirement and citation shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.313.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 10  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.314.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.314.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.6  The Permittee shall vent emissions from EQUIs 152‐167 to TREA 10 whenever EQUIs 152‐167 operate, and operate and maintain TREA 10 at all times that any emissions are vented to TREA 10. The Permittee shall document periods of non‐operation of the control equipment TREA 10 whenever EQUIs 152‐167 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.7  If the Permittee replaces TREA 10, the replacement control must meet or exceed the control efficiency requirements of TREA 10 as well as comply with all other requirements of TREA 10. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use 

Page 85: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 85 of 109 

  

 

Requirement number  Requirement and citation by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.314.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 10 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.314.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.314.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.314.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.314.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 11  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.315.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.315.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency 

Page 86: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 86 of 109 

  

 

Requirement number  Requirement and citation for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.6  The Permittee shall vent emissions from EQUIs 168‐199 to TREA 11 whenever EQUIs 168‐199 operate, and operate and maintain TREA 11 at all times that any emissions are vented to TREA 11. The Permittee shall document periods of non‐operation of the control equipment TREA 11 whenever EQUIs 168‐199 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.7  If the Permittee replaces TREA 11, the replacement control must meet or exceed the control efficiency requirements of TREA 11 as well as comply with all other requirements of TREA 11. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.315.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 11 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.315.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for 

Page 87: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 87 of 109 

  

 

Requirement number  Requirement and citation each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.315.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.315.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.315.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 12  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.316.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.316.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.6  If the Permittee replaces TREA 12, the replacement control must meet or exceed the control efficiency requirements of TREA 12 as well as comply with all other requirements of TREA 12. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 88: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 88 of 109 

  

 

Requirement number  Requirement and citation 

5.316.7  The Permittee shall vent emissions from EQUIs 200‐216 to TREA 12 whenever EQUIs 200‐216 operate, and operate and maintain TREA 12 at all times that any emissions are vented to TREA 12. The Permittee shall document periods of non‐operation of the control equipment TREA 12 whenever EQUIs 200‐216 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.316.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 12 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.316.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.316.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.316.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.316.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 13  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.317.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.317.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change. 

Page 89: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 89 of 109 

  

 

Requirement number  Requirement and citation  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.6  The Permittee shall vent emissions from EQUIs 217‐242 to TREA 13 whenever EQUIs 217‐242 operate, and operate and maintain TREA 13 at all times that any emissions are vented to TREA 13. The Permittee shall document periods of non‐operation of the control equipment TREA 13 whenever EQUIs 217‐242 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.7  If the Permittee replaces TREA 13, the replacement control must meet or exceed the control efficiency requirements of TREA 13 as well as comply with all other requirements of TREA 13. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.317.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 13 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.317.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the 

Page 90: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 90 of 109 

  

 

Requirement number  Requirement and citation following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.317.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.317.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.317.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 14  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.318.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.318.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.6  The Permittee shall vent emissions from EQUIs 243‐256 to TREA 14 whenever EQUIs 243‐256 operate, and operate and maintain TREA 14 at all times that any emissions are vented to TREA 14. The 

Page 91: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 91 of 109 

  

 

Requirement number  Requirement and citation Permittee shall document periods of non‐operation of the control equipment TREA 14 whenever EQUIs 243‐256 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.7  If the Permittee replaces TREA 14, the replacement control must meet or exceed the control efficiency requirements of TREA 14 as well as comply with all other requirements of TREA 14. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.318.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 14 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.318.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.318.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.318.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.318.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

Page 92: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 92 of 109 

  

 

Requirement number  Requirement and citation 

TREA 15  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.319.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.319.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.6  The Permittee shall vent emissions from EQUIs 257‐286 to TREA 15 whenever EQUIs 257‐286 operate, and operate and maintain TREA 15 at all times that any emissions are vented to TREA 15. The Permittee shall document periods of non‐operation of the control equipment TREA 15 whenever EQUIs 257‐286 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.7  If the Permittee replaces TREA 15, the replacement control must meet or exceed the control efficiency requirements of TREA 15 as well as comply with all other requirements of TREA 15. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.319.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 15 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 93: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 93 of 109 

  

 

Requirement number  Requirement and citation 

5.319.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.319.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.319.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.319.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.319.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 16  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.320.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.320.2  Pressure Drop >= 0.5 and <= 10 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 

Page 94: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 94 of 109 

  

 

Requirement number  Requirement and citation 7007.0200] 

5.320.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.6  The Permittee shall vent emissions from EQUIs 287‐294 to TREA 16 whenever EQUIs 287‐294 operate, and operate and maintain TREA 16 at all times that any emissions are vented to TREA 16. The Permittee shall document periods of non‐operation of the control equipment TREA 16 whenever EQUIs 287‐294 are operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.7  If the Permittee replaces TREA 16, the replacement control must meet or exceed the control efficiency requirements of TREA 16 as well as comply with all other requirements of TREA 16. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.320.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 16 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.320.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.320.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

Page 95: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 95 of 109 

  

 

Requirement number  Requirement and citation 

5.320.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.320.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 17  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.321.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.321.2  Pressure Drop >= 0.5 and <= 12 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.6  The Permittee shall vent emissions from EQUI 306 to TREA 17 whenever EQUI 306 operates, and operate and maintain TREA 17 at all times that any emissions are vented to TREA 17. The Permittee shall document periods of non‐operation of the control equipment TREA 17 whenever EQUI 306 is operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.7  If the Permittee replaces TREA 17, the replacement control must meet or exceed the control efficiency requirements of TREA 17 as well as comply with all other requirements of TREA 17. Prior to making such a change, the Permittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

Page 96: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 96 of 109 

  

 

Requirement number  Requirement and citation 

5.321.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.321.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 18 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.321.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.321.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.321.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.321.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

TREA 18  Fabric Filter ‐ Low Temp, T<180 Degrees F 

5.322.1  Opacity <= 10 percent opacity discharged from control equipment. [Minn. R. 7011.1005, subp. 3(D)] 

5.322.2  Pressure Drop >= 0.5 and <= 12 inches of water, unless a new range is set pursuant to Minn. R. 7017.2025, subp. 3 based on the values recorded during the most recent MPCA‐approved performance test where compliance was demonstrated. The new range shall be implemented upon receipt of the Notice of Compliance letter granting preliminary approval. The range is final upon issuance of a permit amendment incorporating the change.  If the recorded pressure drop is outside the required range, the emissions during that time shall be considered uncontrolled until the pressure drop is once again within the required range. The period of time for which the pressure drop is considered out of range shall be reported as a deviation. The Permittee shall record the pressure drop at least once every 24 hours when in operation. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major 

Page 97: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 97 of 109 

  

 

Requirement number  Requirement and citation source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.3  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for Particulate Matter >= 99 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.4  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 10 micron >= 93 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.5  The Permittee shall operate and maintain control equipment such that it achieves a control efficiency for PM < 2.5 micron >= 80 percent control efficiency. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.6  The Permittee shall vent emissions from EQUI 307 to TREA 18 whenever EQUI 307 operates, and operate and maintain TREA 18 at all times that any emissions are vented to TREA 18. The Permittee shall document periods of non‐operation of the control equipment TREA 18 whenever EQUI 307 is operating. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.7  If the Permittee replaces TREA 18, the replacement control must meet or exceed the control efficiency requirements of TREA 18 as well as comply with all other requirements of TREA 18. Prior to making such a change, the ermittee shall apply for and obtain the appropriate permit amendment, as applicable.   If no amendment is needed for the replacement, the Permittee shall submit an electronic notice to the Agency using Form CR‐05. The notice must be received by the Agency seven working days prior to the commencement/start of replacement. [Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.8  The Permittee shall operate and maintain the fabric filter in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. [Minn. R. 7007.0800, subp. 14] 

5.322.9  Visible Emissions: The Permittee shall check the fabric filter stack STRU 19 for any visible emissions once each day of operation during daylight hours. During inclement weather, the Permittee shall read and record the pressure drop across the fabric filter, once each day of operation. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.10  Recordkeeping of Visible Emissions and Pressure Drop. The Permittee shall record the time and date of each visible emission inspection and pressure drop reading, and whether or not any visible emissions were observed, and whether or not the observed pressure drop was within the range specified in this permit. [Minn. R. 7007.0800, subps. 4‐5, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

5.322.11  Corrective Actions: The Permittee shall take corrective action as soon as possible if any of the following occur: ‐ visible emissions are observed; ‐ the recorded pressure drop is outside the required operating range; or ‐ the fabric filter or any of its components are found during the inspections to need repair. Corrective actions shall return the pressure drop to within the permitted range, eliminate visible emissions, and/or include completion of necessary repairs identified during the inspection, as 

Page 98: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 98 of 109 

  

 

Requirement number  Requirement and citation applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the fabric filter. The Permittee shall keep a record of the type and date of any corrective action taken for each filter. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 2(A), Minn. R. 7007.0800, subp. 5] 

5.322.12  Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored fabric filter is in operation. [Minn. R. 7007.0800, subp. 4] 

5.322.13  The Permittee shall calibrate or replace the pressure drop monitor at least once every 12 months and shall maintain a written record of any action resulting from the calibration. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

5.322.14  Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. [Minn. R. 7007.0800, subp. 14, Minn. R. 7007.0800, subp. 4, Minn. R. 7007.0800, subp. 5] 

  6. Submittal/action requirements  

This section lists most of the submittals required by this permit. Please note that some submittal requirements may appear in the Limits and Other Requirements section, or, if applicable, within a Compliance Schedule section. 

 

Requirement number   Requirement and citation 

TFAC 1  Ardent Mills LLC 

6.1.1  The Permittee shall submit a semiannual deviations report : Due semiannually, by the 30th of January and July. The first semiannual report submitted by the Permittee shall cover the calendar half‐year in which the permit is issued. The first report of each calendar year covers January 1 ‐ June 30. The second report of each calendar year covers July 1 ‐ December 31. Submit this on form DRF‐2 (Deviation Reporting Form). If no deviations have occurred, submit the signed report certifying that there were no deviations. [Minn. R. 7007.0800, subp. 6(A)(2)] 

6.1.2  The Permittee shall submit a compliance certification : Due annually, by the 31st of January (for the previous calendar year). Submit this on form CR‐04 (Annual Compliance Certification Report). This report covers all deviations experienced during the calendar year. If no deviations have occurred, submit the signed report certifying that there were no deviations. [Minn. R. 7007.0800, subp. 6(C)] 

COMG 2  Feed Loadout 

6.2.1  Opacity: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure opacity.  The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, 

Page 99: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 99 of 109 

  

 

Requirement number   Requirement and citation subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using the Alternative Test Method for Opacity Determination of Emissions from Intermittent Dust‐Generating Operations found in Appendix B of this permit, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1] 

EQUI 1  Rail and Truck Unload Pit 

6.3.1  Opacity: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure opacity.  The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using the Alternative Test Method for Opacity Determination of Emissions from Intermittent Dust‐Generating Operations found in Appendix B of this permit, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1] 

FUGI 4  Fugitive HAP Sources (Fumigation, Preservation, etc.) 

6.4.1  The Permittee shall submit an annual report by the 31st of January. The report shall document the HAP 12‐month rolling sum calculations for the previous calendar year. The report shall be submitted with the annual Compliance Certification required by this permit. As part of the Annual Report, the Permittee shall verify and certify that the Facility has maintained minor source status for National Emission Standards for Hazardous Air Pollutants and Part 70. [Minn. R. 7007.0800, subp. 2(A)] 

STRU 6  Filter 11 A‐Mill Pneumatics Stack Vent 

6.5.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.  

Page 100: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 100 of 109 

  

 

Requirement number   Requirement and citation  If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.5.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 7  Filter 12 A‐Mill Pneumatics Stack Vent 

6.6.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for 

Page 101: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 101 of 109 

  

 

Requirement number   Requirement and citation an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.6.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 8  Filter 13 A Mill Purifiers Stack Vent 

6.7.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.  

Page 102: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 102 of 109 

  

 

Requirement number   Requirement and citation  The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.7.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 9  Filter 14 A Mill Purifiers Stack Vent 

6.8.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, 

Page 103: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 103 of 109 

  

 

Requirement number   Requirement and citation subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.8.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 10  Filter 15 B Mill Purifiers Stack Vent 

6.9.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval. 

Page 104: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 104 of 109 

  

 

Requirement number   Requirement and citation  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.9.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 11  Filter 16 B Mill Pneumatics Stack Vent 

6.10.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date 

Page 105: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 105 of 109 

  

 

Requirement number   Requirement and citation for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.10.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 12  Filter 24 C Mill Purifiers Stack Vent 

6.11.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  

Page 106: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 106 of 109 

  

 

Requirement number   Requirement and citation Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.11.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

STRU 13  Filter 26 C Mill Pneumatics Stack Vent 

6.12.1  PM < 10 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance 

Page 107: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 107 of 109 

  

 

Requirement number   Requirement and citation test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

6.12.2  PM < 2.5 micron: The Permittee shall conduct an initial performance test due 180 calendar days after Initial Startup Date and at a minimum every 60 months thereafter to measure emissions.   The Commissioner will set the subsequent test frequency as stated in a Notice of Compliance (NOC) or Notice of Verification (NOV) letter with review of the initial performance test. Subsequent tests shall be completed no less than every 60‐months by the due date (month and day) based on the initial test date or more frequently as stated in the NOC/NOV letter.   If the Commissioner sets a test frequency at less than every 60 months, the Permittee must apply for an administrative amendment to incorporate the prescribed test frequency into the permit. A major amendment is required to reduce the test frequency once set in the permit.   The performance test shall be conducted at worst‐case conditions defined at Minn. R. 7017.2005, subp. 8 or at the operating conditions described at Minn. R. 7017.2025, subp. 2, using EPA Reference Methods 201A and 202, or other method approved by MPCA in the performance test plan approval.  Testing conducted during the 60 days prior to a performance test due date will not reset the due date for future testing.  Testing conducted more than 60 days prior to the specified due date satisfies this test due date requirement but will reset future performance test due dates based on the most recent performance test date. [Minn. R. 7017.2020, subp. 1, Title I Condition: Avoid major source under 40 CFR 52.21(b)(1)(i) and Minn. R. 7007.3000, To avoid major source under 40 CFR 70.2 & Minn. R. 7007.0200] 

  7. Appendices 

 Appendix A. Insignificant activities and general applicable requirements  The table below lists the insignificant activities that are currently at the Facility and their associated general applicable requirements. 

 

Minn. R.  Rule description of the activity  General applicable requirement 

Minn. R. 7007.1300, subp. 3(G)  Fugitive dust emissions from unpaved roads and parking lots 

Requirement to take reasonable measures to prevent PM from becoming airborne (Minn. R. 7011.0150) 

  

Appendix B. Alternative Test Method for Opacity Determination of Emissions from Intermittent Dust‐Generating Operations (alternative to Method 9). 

1.1 Applicability: This method is applicable for the determination of opacity of fugitive dust plumes from intermittent dust‐generating operations. 

Page 108: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 108 of 109 

  

 

1.2 Principle: The opacity of emissions from sources of visible emissions is determined visually by a qualified observer certified according to the procedure in EPA Test Method 9.  

1.3 Procedures: A qualified observer shall use the following procedures for visually determining the opacity of emissions. The Commissioner may approve changes to the alternative test method, in lieu of the test method described below, and based upon the criteria described in Minn. R. 7017.2050, subp. 2, items A and B.  

1.3.1 To determine the opacity of non‐continuous dust plumes caused by activities including, but not limited to, bulk material loading/unloading, bulk material handling, reclaim activities, and truck traffic within a bunker: 

a. Position: The qualified observer must stand at least 25 feet, but no more than 200 feet from the dust‐generating operation in order to provide a clear view of the emissions with the sun oriented in the 140º sector to their back. Choose a discrete portion of the operation for observation, such as the unloading point, not the whole operation. As much as possible following the above requirements, make opacity observations so that the line of vision is perpendicular to the dust plume and wind direction. If multiple plumes are involved, do not include more than one plume in the line of sight at one time. 

b. Initial Fallout Zone: Opacity readings should be taken at the maximum point of the entrained fugitive dust plume that is located outside the initial fallout zone. The initial fallout zone is that area where the heaviest particles drop out of the entrained fugitive dust plume. The initial fallout zone within the plume must be identified. Record the distance from the equipment or path that is your identified initial fallout zone (provide a sketch to provide scale).  

  c. Field Records: Note the following on an observational record sheet: 

(1) Location of dust‐generating operation, type of operation, type of equipment in use and activity, and method of control used, if any; 

(2) Observer's name, certification data and affiliation, a sketch of the observer's position relative to the dust‐generating operation, and observer’s estimated distance and direction to the location of the dust‐generating operation; 

(3) Time that readings begin, approximate wind direction, estimated wind‐speed, description of the sky condition (presence and color of clouds); 

(4) Color of the plume and type of background; and 

(5) Sketch of Initial Fallout Zone location relative to the emission source. 

 d. Observations: Make opacity observations, to the extent possible, using a contrasting background that is perpendicular to the line of vision. Make two observations per discrete activity, beginning with the first reading at zero seconds and the second reading at five seconds. The zero‐second observation should begin immediately after a plume has been created above the surface involved. Do not look continuously at the plume but, instead, observe the plume briefly at zero seconds and then again at five seconds. 

e. Recording Observations: Record the opacity observations to the nearest 5% on an observational record sheet. Each momentary observation recorded represents the average opacity of emissions for a five‐second period. Repeat observations until you have recorded at least a total of 12 consecutive opacity readings. The 12 consecutive 

Page 109: Intent to Issue Air Emission Permit to Ardent Mills LLC, Lake City · 2019-10-10 · TFAC 1: Ardent Mills LLC ACTV 4: All IAs COMG 1: Flour Blending & Truck Loading has members EQUI

Permit Issued:  [month day, year]  15700034‐101 Permit Expires:  [month day, year]  Page 109 of 109 

  

 

readings must be taken within the same period of observation but must not exceed one hour. Observations immediately preceding and following interrupted observations can be considered consecutive (e.g., vehicle traveled in front of path, plume doubled over). 

f. Data Reduction: Opacity is determined as the average of 12 consecutive opacity readings. Divide the observations into sets of 12 consecutive observations. In no case shall two sets overlap. For each set of 12 observations, calculate the average by summing the opacity of the 12 observations and dividing this sum by 12. If an applicable standard or requirement specifies a different averaging time, calculate the average for the observations in accordance with the specified time period. Record the average opacity on a record sheet. If the average opacity reading equals 20% or lower, the dust‐generating operation is in compliance. 

The existence of visible emissions only (not a specific opacity) is determined visually by an observer using EPA Test Method 22. The observer using EPA Test Method 22 is not required to be certified.