intensive care ventilator & patient monitor product … · mode vacv pacv simv spont apnea...
TRANSCRIPT
ICU Ventilator
· MV2000, MV2500
· MC200
· MS10
High Flow Therapy
· HFT500
Transport Ventilator
· MTV1000
Patient Monitor
· MP1300
· MP1000NTP
· MP800
EtCO2 Monitor
· MP800C
Pulse Oximeter
· MP570T
· MP110 Plus
· MP111
Veterinary Monitor
· MP1000Vet
· MP800Vet
EMR System
· MP601
· HIS(EMR) System
Product line upMEK-ICS CO., LTD
Intensive Care Ventilator & Patient Monitor Product Catalogue
- 2 - - 3 -
Specifications
SU:M SERIES
Alarm Setting Parameters (MAIN)
Intensive Care Ventilator & Patient Monitor ICU Ventilator
- 4 - - 5 -
Feature SU:M1 SU:M2 SU:M3 SU:MHFV
MODE
VACV
PACV
SIMV
SPONT
Apnea Backup
Mask Ventilation (Non-Invasive)
PRVC
tBi-Level
Auto Vent®
High Frequency Ventilation (SHFV/DHFV)
Nubulizer Auto Nubulizer
Optional
O2 Stream (with Nasal Cannular)
Hemo-Dynamics (SpO2& EtCO2)
Proximal Sensor (Adult&Neonate)
TCPL + PV-TOOL
Standby Trend
Vent Mode Vent Setting
Vent Run X-Y Graph
Intelligent Technology
System Mechanism
Block Type Pneumatic SystemHigh performance Block type pneumatics and microprocessor controlled electronic hardware system, allows sensitive and precise breath delivery for critically ill patients.
Advanced Proportional Solenoid Valve (PSOL) TechnologyEnsures faster, safer and accurate gas delivery which also reduces the Work of Breathing and helps in improving Synchrony.
Active Exhalation ValveActively controls and maintains the target pressure. It allows unrestricted breathing during both inspiratory as well as expiratory phases of the breathing cycles. This valve also vents excess pressure due to Pressure overshoot, patient’s cough, etc. This promotes better Patient - Ventilator Synchrony and potentially decreases the need for sedation.
Differential Type Flow SensorSensor is very rugged and reliable offering exceptional response, as well as, accurate monitoring, even when used with a Nebulizer.Designed with a high end pneumatic base, and using a Differential Type Flow Sensor, the SU:M series assures the user of long service time intervals, The low cost of spares and very few consumables provides the customer with very affordable cost of ownership.
TrendTrend mode simultaneously displays the past records of patient’s statues in numeric, as well as, graphical form. By adjusting the cursor, the user can revew the monitored data for any specific time, in the past 72 hours. The built in trend function record up to 11 parameters such as Volume, Pressure, Flow etc, with a selectable time interval if 1/10/30/60 breaths.
Advanced Technology
Optimize System
Automatic Measurement of both Altitude and Temperature: An Aritifcial Intelligence internal sensor to measure Altitude and Temperature.The volume of atmosphere is changeable depending on Height, Humidity and Temperature. Its measurement result is relative considering the environments condition. Most conventional Ventilators measures Temperature and Altitude by each users, which can be inaccurate, however with MEKICS's internal acute Altimeter and Thermometer, a volume for each patient will have absolute precision.
Auto Peak Flow: Automatic setup for its convenience. Every person has a different weight, lung capacity and breathing period. Until now, SU:M series has its auto measruement function to calculate Ideal Body Weight, Breathing Volume and Inspiration period for each patient to indicate a Auto Peak Flow data. Just touch the screen for results.
Maintenance and System Check with an unique program: Susceptible Maintenance Program for Technical Support.Due to its feature, life-saver, the accuracy is the most significant fact to handle. For a fine data adjustment, MEK ICS provides the strong maintenance program for easy access and control.
Mask Ventilator
Mask Ventilation is the most basic, yet the most essential, skill in airway management. It is the primary technique of ventilation tracheal intubation or insertion of any airway device. Its most unique role, however, is as a rescue technique for ventilation should tracheal intubation fail or prove difficult. MEK Mask Ventilation on/off mode maximizes its leakage compensation up to 50LPM.
Additional Options
▪ O2 Stream
▪ Proximal Sensor
▪ Hemo-Dynamics function
Intelligent Ventilator for ICUThe intelligent Ventilator has its functions to be adaptable for ICU. However, MEK ICS's ICU Ventilator, SU:M series, is compatible to cover all ages from an Adult to a Neonate in an Intensive Care Unit. All in One.
Proximal Sensor port
EtCO2 and SpO2 port
Intensive Care Ventilator & Patient Monitor ICU Ventilator
- 6 - - 7 -
MC200Air Compressor
Air Compressor Unit - MC200
MC200 is originally designed to use our ICU ventilators. In case of using other manufacturer’s ventilator to MC200, it is recommended to check the maximum capacity of flow consumption of the connected ventilator and the maximum capacity of flow production of MC200.
▪ Compact size
▪ Portable type for easy install and move
▪ Low noise by double silencer system
▪ Absorption of vibration & dust-protection applied structure enable MC200 to perform superior vibration coefficient with extremely quiet operation
▪ User convenient display
▪ Total used time display enable timely effective maintenance efforts
▪ Easy maintenance by cartridge type replacement of service parts
▪ Parallel connection to WALL AIR is available
▪ Safety solution useful for preventive maintenance (e.g. Temperature warning system & manual shut down is available)
▪ Available to operate in connection with maximum 2 units of ventilator simultaneously (Use on MEKICS ICU ventilator series)
Adaptive Scavenging System - MS10
secondary infection.
MS10 is differ from a passive system that is possible to recover 100% gas without flow adjustment and it is not effected on the main device(Ventilator) even at high flow by active control and internal high compliance.
Intensive Care Ventilator & Patient Monitor Medical compressor Adaptive Scavenging System
- 10 - - 11 -
Intensive Care Transportable Ventilator
Pneuma
Graphic Waveform
Alarm
Alarm Setting Parameters (MAIN)
High tidal volume Expiratory volume
High respiration rate
Low respiration rate
High peak airway pressure
Low peak airway pressure
High O2 %
Low O2 %
Apnea
Ventilator in-operation
(Option, SpO2)
High SpO2
Low SpO2
High pulse rate (SpO2)
Low pulse rate (SpO2)
Key, Indicators
Inspiration hold Measures patient's lung compliance and resistance
Elasticity, Time constant
Key lock Key & LCD Touch Screen Lock
Graph freeze
Alarm silence Mutes audible alarms for 2 minutes
Alarm reset Clears visual indicators and messages
Electrical Requirements
Power AC : 100-230 VAC, 50/60 Hz (Free voltage)
DC : 10.8V 8.8A, Internal battery
Provides Max. 180 minutes of normal operation
Physical Characteristics
Weight 6.1 kg (main unit)
Dimensions 25 x 15.6 x 37.1 (Width x Depth x Height) cm
Environmental Requirements
Atmospheric condition 700 to 1060 mbar (10.2 ~ 15.4 psi)
Altitude -443 ~ 3048 m (-1350 ~ 10,000ft )
Height Up to 6560 m (20,000 ft )
Conditions of use 10 to 40 (50 ~ 104 )
Relative humidity 10 to 85 %
Pneumatic Requirements
Oxygen inlet supply pressure 2.46 to 6.32 kgf/cm2 / 2.4 to 6.2 bar (35 to 90 psig)Feature
Pneuma2 Pneuma1 PneumaCare PneumaCareO2Dual limb Single limb Dual limb Single limb Single limb Single limb
MODE
PACV
VACV
VSIMV
PSIMV
Spont+
Auto
PRVC
O2 Stream®
ACPAP+
ABIPAP+
Peripherals
High PressureOxygen MixerLow Flow O2
Input
Proximal Pressure Input
Exhalation Valve Assembly
Exhalation Drive Line Outlet
OptionalEtCO2
SpO2
Intensive Care Ventilator & Patient Monitor Transport Ventilator Transportable Ventilator
- 12 - - 13 -
Single Limb Ex-valve is marked RED circle.
Home Care.
Transport.
Hospital.
Intensive Care Ventilator & Patient Monitor
Trigger
Pressure
Flow-Machine
Flow-PatientEx.time
=Easy Expiration
PSV
Quick Pause
Encorder for setting parameter 7” Color TFT Touch Screen
LAN, USB RS-232 Upgrade port
Optional : SpO2, EtCO2
Proximal Pressure Line InputExhalation Drive Line Outlet
Built in a High PerformanceBlower System
Transport Ventilator for Acute Care, Sub-Acute Care,Homecare and Transport
Transportable Ventilator
Single limb circuit use
PneumaCare Series
PneumaCare
PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS), PRVC, ACPAP+, ABiPAP+ Optional : SpO2, EtCO2
PneumaCareO2
PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS), PRVC, ACPAP+, ABIPAP+, O2 Stream® with high flow oxygen supply.With High Pressure Oxygen MixerOptional : SpO2, EtCO2, Nasal Cannula for O2Stream®
ACPAP+
(Adaptive CPAP Plus Pressure Support)®
[ACPAP+ Function] It is developed with high technology which applying to the highest class ICU ventilator and applying for a patent. It is innovated reaserch object ‘comfortable breathing’ in CPAP. MEKICS created unique ACPAP+ technology completed the clinical effect and ‘comfortablebreathing’ simultaneous.
[Principal] Based on the CPAP, it is contrived to minimize of breaths with difficulty in CPAP as induction of airway open, pressure support that is decreased patient’s effort in inspiration, and active break (rapid pressure interruption) that makes easy of expiration.
[Technology]
It is decreased Inspiratory Phase Work of Breathing through Inspiratory Trigger function and Pressure Support function. It makes possible to inhalation with small effort of patient (WOB_inspiration). It is decreased Expiratory Phase Work of Breathing through Ex_Sesnse. In this time, interrupt the flow rapidly and supply brk_time (Expiration Break Time). It makes possible to exhalation with small effort of patient (WOB_expiration) and minimize of breaths with difficulty.
* (brk_time: Expiration Break Time): Application to most convenience respiration pattern.
- 16 - - 17 -
Products Line Up
Of Respiratory CareHigh Flow Trerapy
OmniOxThe HFT500 is the total solution for “Successful Non-Invasive Respiratory Care.”
High Flow TrerapyOmniOxThe HFT500 is the total solution for “Successful Non-Invasive Respiratory Care.”
High Flow Therapy
It is non-invasive breathing treatments to improve of lung oxygenation that as supplying the heated and humidified oxygen requirements that exceed the patient’s inspiratory flow rate through nose, reduce the intake of breath work, increase the functional residual capacity by rising of PEEP, optimize the nasal and the status of the mucosa of the upper respiratory track, and reduce the residual gas exhalation of dead space anatomically.
High Flow Trerapy Pruducts Line Up
- 19 - - 18 -
0,30~250bpm
0.05~20%
0.1
45
0
20
10~500~25
250
50
2
0.1
45
9
0
Dose calculator
Intensive Care Ventilator & Patient Monitor Patient Monitor Patient Monitor
- 20 - - 21 -
30~250
0
1
45
30
0
0~15040
41~70
1
45
250
0
10
Intensive Care Ventilator & Patient Monitor Patient Monitor Patient Monitor & Pulse Oximeter
- 22 - - 23 -
250
1
250
0
Veterinary Monitor
MP1000NTP VetVeterinary Monitor
MP800 Vet
• 10.4” superior resolution TFT color LCD • 7 waveform display• ECG+Resp, SpO2, NIBP, 2-IBP, 2-Temp.• Full Arrhythmia analysis and ST segment analysis• Save up to 30 event management• Virtual screen system for various viewing• 72-hours tabular and graphic trend
• 6.4” high quality resolution TFT color LCD• 3/5-lead ECG, RESP, SpO2, NIBP, TEMP.• Arrhythmia Analysis and ST segment analysis• Pacemaker Detection• Virtual screen system for various viewing• 72hours tabular and graphic trend• ECG lead auto detection (3 lead or 5 lead)
ECGChannel 3 channels3 leadwire I, II, III5 leadwire I, II, III, aVR, aVL, aVF, CGain 2.5, 5, 10, 15, 20 mm/mVHeart rate 0, 20 ~ 300bpm
RespirationMethod ECG Lead(selectable)Respiration rate 0, 2 ~ 150 bpm
SpO2
Range 0 ~ 100%Pulse Rate 0, 30 ~ 300bpm
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean
Last 3 measurement
Invasive blood pressureNumber of channel Max. 2channelsMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SP
2-TemperatureSensor YSI 400 series compatible(optional)Measurement range 0~50°C
EtCO2(optional) Main stream or Side streamMeasurement range 0-99 mmHgRespiration range 0~150 bpm
ECGChannel 1 channel3 leadwire I, II, III5 leadwire I, II, III, aVR, aVL, aVF, CGain 2.5, 5, 10, 15, 20 mm/mVHeart rate 0, 20 ~ 300 bpm
RespirationMathod ECG Lead(selectable)Respiration rate 0, 2 ~ 150 bpm
SpO2
Range 0 ~ 100%Pulse Rate 0, 25 ~ 300bpm
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean
Last 3 measurement
TemperatureSensor YSI 400 series(optional)Measurement range 0~50°C
Intensive Care Ventilator & Patient Monitor Patient Monitor & Pulse Oximeter Veterinary Monitor
- 24 - - 25 -
Intensive Care Ventilator & Patient Monitor Central monitoring & EMR system
Products Line Up
Of Patient Monitor and Pulse Oximeter
- 26 - - 27 -
Pruducts Line Up
Specification subject to be changed without notice
P/N : MEK-CAT-1310(Ver2.3) Printed in KOREA Oct. 2013 Oct.
2013
. Des
igne
d by
BizP
lus
AD In
c. w
ww.b
izplu
sad.
co.k
r
Head Office. 40, Toegyegongdan 1-gil, Chuncheon-si, Gangwon-do, Korea 200-944Seongnam Office. A-5F, woolim lions valley 5th, 302 Galmachi-ro, Jungwon-gu, Seongnam-si,
Gyeonggi-do, Korea 462-807TEL. 070-7119-2520 FAX. 031-735-2761 www.mek-ics.com e-mail. [email protected]