intelligent & basic power distribution units (pdu)€¦ · technologies to address the needs of...

5
www.conteg.com All rights reserved, CONTEG © 2013 1 CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420 261 219 182 Fax: +420 261 219 192 Production plant in the Czech Republic: K Silu 2179 393 01 Pelhřimov Tel.: +420 565 300 300 Fax: +420 565 533 955 Local Branches/Offices Austria: +43 170 659 0115 Benelux: +32 477 957 126 Eastern Europe / Nordics: +49 172 8484 346 France, Maghreb: +33 686 074 386 Germany / Switzerland / Baltics / Denmark / Italy: +49 170 523 4958 India: +91 99 1695 0773 Middle East: +971 4445 2838 Russia, CIS: +7 495 967 3840 [email protected] www.conteg.com CONTEG DATASHEET version: 27-05-2013 INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU) COMPLEMENTARY SYSTEMS

Upload: others

Post on 11-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)€¦ · technologies to address the needs of the high-density computing user. The range comprises power strips which feature either

www.conteg.comAll rights reserved, CONTEG © 2013

1

CONTEG, spol. s r.o.Czech Republic Headquarters:Na Vítězné pláni 1719/4140 00 Prague 4Tel.: +420 261 219 182 Fax: +420 261 219 192

Production plant in the Czech Republic:K Silu 2179393 01 PelhřimovTel.: +420 565 300 300Fax: +420 565 533 955

Local Branches/OfficesAustria: +43 170 659 0115Benelux: +32 477 957 126Eastern Europe / Nordics: +49 172 8484 346France, Maghreb: +33 686 074 386Germany / Switzerland /Baltics / Denmark / Italy: +49 170 523 4958India: +91 99 1695 0773 Middle East: +971 4445 2838Russia, CIS: +7 495 967 3840

[email protected]

CONTEG DATASHEET

version: 27-05-2013

INTELLIGENT & BASIC POWER DISTRIBUTION UNITS

(PDU)

COMPLEMENTARY SYSTEMS

Page 2: INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)€¦ · technologies to address the needs of the high-density computing user. The range comprises power strips which feature either

www.conteg.comAll rights reserved, CONTEG © 2013

2

INTELLIGENT & BASIC POWER DISTRIBUTION UNITS

BASIC POWER

The Conteg Intelligent & Basic Power product range comprises three different technologies to address the needs of the high-density computing user. The range comprises power strips which feature either no intelligence (Basic), the ability to remotely monitor current draw per strip using Ethernet and IP (Monitored range) or the ability to fully manage power strips and groups of power strips across the network (Managed range). Conteg Intelligent & Basic Power offers a combination of outlets, including national outlet styles combined with industrial outlets, high-amperage inputs and both 1-phase and 3-phase powered models. Standard 1-phase input plug styles include the EN60 309 16 A and 32 A type or the IEC-C20 or Schuko/UTE, which are also rated for 16 A operation. The standard 3-phase input plug is EN60 309 3×16 A.

Managed PDU

Monitored PDU

Basic PDU with DP‑RP‑VM‑02

Monitored PDU

These Basic Power Distribution Units are designed for standard applications without the above standard safety or operational requirements. These models provide reliable power to the cabinet for a standard environment.

* panels contain HF filter1 for vertical installation use DP‑RP‑VM‑012 for vertical installation use DP‑RP‑VM‑02, see above picture “Basic PDU with DP‑RP‑VM‑02”

DESCRIPTION:• Types:

a) 19" mounting b) 10" mounting c) free-standing d) vertical• Outlet types: UTE, SCHUKO, UK, IEC320 C13,

IEC320 C19• Other outlet types in combination with surge

protection and ammeter also available• Power output:

- SCHUKO, UTE, IEC320 C19: 16 A, 250 V - UK: 13 A, 250 V - IEC320 C13: 10 A, 250 V• Power input:

- all types with 3 m power cord - UK plug for PDU with UK outlets - Schuko/UTE plug for all other PDUs

BASIC POWER DISTRIBUTION UNITS – FOR STANDARD ENVIRONMENT

Code Mounting H in U Outlettype Qty Over voltage

protection Switch

DP-RP-02-UK 10" 1 UK 2 No No

DP-RP-03-UTE 10" 1 UTE 3 No No

DP-RP-03-SCHU 10" 1 SCHUKO 3 No No

DP-RP-06-UTESP 1 * 19" 2 UTE 6 Yes Yes

DP-RP-06-SCHUSP 1 * 19" 2 SCHUKO 6 Yes Yes

DP-RP-06-UTESP-F free - UTE 6 Yes Yes

DP-RP-06-SCHUSP-F free - SCHUKO 6 Yes Yes

DP-RP-06-UKS 1 19" 1 UK 6 No Yes

DP-RP-07-UK 1 19" 1 UK 7 No No

DP-RP-08-UTES 1 19" 1 UTE 8 No Yes

DP-RP-08-SCHUS 1 19" 1 SCHUKO 8 No Yes

DP-RP-09-UTE 1 19" 1 UTE 9 No No

DP-RP-09-SCHU 1 19" 1 SCHUKO 9 No No

DP-RP-09-IECC19 1 19" 1 IEC320 C19 9 No No

DP-RP-12-IECC13 1 19" 1 IEC320 C13 12 No No

DP-RP-20-IECC19 2 vertical - IEC320 C19 20 No No

DP-RP-20-IECC13 2 vertical - IEC320 C13 20 No No

DP-RP-20-SCHUV 2 vertical - SCHUKO 20 No No

DP-RP-20-UTEV 2 vertical - UTE 20 No No

Page 3: INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)€¦ · technologies to address the needs of the high-density computing user. The range comprises power strips which feature either

www.conteg.comAll rights reserved, CONTEG © 2013

3

Strips feature a local easy-to-read ammeter on the outlet strip along with the ability to monitor the current draw of outlets remotely over an Ethernet connection. The user can aggregate the information from thousands of Intelligent Power Strips in one location. Designed for high-density, mission-critical server applications, the Conteg Monitored power strips provide reliable power to the cabinet for both standard and blade server environments.

The enhanced version of the monitored strip also offers voltage and frequency metering. Hence the PDU is able to report the power factor, active and apparent power and main energy consumed in kWh. A calculation of carbon emission data (CO2 footprint) and the price estimation of consumed energy is also made.

monitored PDU

INTELLIGENT POWER MONITORED

INTELLIGENT POWER DISTRIBUTION UNITS – MONITORED

Code Input plug Length Type 1 outlet Qty Type 2

outlet Qty Rating MountingDimensions in mm

H W D

IP-DMI-008C3 00 016 C20 x 1 C13 8 x x 16 A 1U 432 44 90

IP-DMI-021C33C916 C20 x 1 C13 21 C19 3 16 A 0U 1 645 44 56

IP-DMI-314C32C932 EN 60 309 3 m C13 14 C19 2 32 A 0U 1 245 44 56

IP-DMI-321C33C932 EN 60 309 3 m C13 21 C19 3 32 A 0U 1 645 44 56

IP-DMI-321C33C911 EN 60 309 3 m C13 21 C19 3 3× 16 A 0U 1 778 44 56

IP-DMI-318C36C922 EN 60 309 3 m C13 18 C19 6 3× 32 A 0U 1 778 44 56

INTELLIGENT POWER DISTRIBUTION UNITS - ENHANCED MONITORED (kWh)

IP-DEI-008C3 00 016 C20 x 1 C13 8 x x 16 A 1U 432 44 90

IP-DEI-321C33C932 EN 60 309 3 m C13 21 C19 3 32 A 0U 1 645 44 56

1 INPUT power cords for these models must be ordered separately (see table page 127)

Basic PDU

BASIC POWER DISTRIBUTION UNITS – FOR STANDARD AND BLADE SERVER ENVIRONMENTS

Code Input plug Length Type 1 outlet Qty Type 2

outlet Qty Rating MountingDimensions in mm

H W D

IP-BA-308UK8C916 EN 60 309 3 m UK 8 C19 8 16 A 0U 860 44 44

IP-BA-312UK8C316 EN 60 309 3 m UK 12 C13 8 16 A 0U 985 44 44

IP-BA-308SH8C916 EN 60 309 3 m SCHUKO 8 C19 8 16 A 0U 722 44 44

IP-BA-312SH8C316 EN 60 309 3 m SCHUKO 12 C13 8 16 A 0U 777 44 44

IP-BA-308UT8C916 EN 60 309 3 m UTE 8 C19 8 16 A 0U 780 44 44

IP-BA-312UT8C316 EN 60 309 3 m UTE 12 C13 8 16 A 0U 865 44 44

IP-BA-320C34C916 EN 60 309 3 m C13 20 C19 4 16 A 0U 908 44 44

IP-BA-C20C34C916 C20 3 m C13 20 C19 4 16 A 0U 908 44 44

IP-BA-C08C3 00 016 C20 3 m C13 8 None 0 16 A 1U 439 44 44

IP-BA-320C34C932 EN 60 309 3 m C13 20 C19 4 32 A 0U 1 038 44 44

IP-BA-306C9 00 011 EN 60 309 3 m C19* 6 None 0 3× 16 A 1U 439 44 44

IP-BA-306SH00 011 EN 60 309 3 m SCHUKO 6 None 0 3× 16 A 1U 439 44 44

IP-BA-306UT00 011 EN 60 309 3 m UTE 6 None 0 3× 16 A 1U 439 44 44

IP-BA-306C9 00 022 EN 60 309 3 m C19* 6 None 0 3× 32 A 1U 439 44 145

These Basic Power Distribution Units are designed for high-density, mission-critical server applications. These models provide reliable power to the cabinet for both standard and blade server environments.

DP‑RP‑09‑UTE DP‑RP‑12‑IECC13DP‑RP‑09‑SCHU

* C19 sockets with lock mechanism (IEC lock)

Page 4: INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)€¦ · technologies to address the needs of the high-density computing user. The range comprises power strips which feature either

www.conteg.comAll rights reserved, CONTEG © 2013

4

INTELLIGENT POWER MANAGED

managed PDU

Strips represent the leading edge in functionality available in a power strip. Employing a  server-grade microprocessor, this product has unprecedented management and monitoring capabilities available through the built in web-server and firewall.

• Switch individual outlets on or off to enable remote reboot of servers• Virtual grouping of outlets for single-click reboot of multi-corded

servers• Single-click control of entire racks or non-critical loads• Current monitoring per outlet (POM)• User-definable sequencing of outlets for reboot

Designed for high-density, mission-critical server applications, the Conteg Managed power strips provide reliable power to the cabinet in both standard and blade-server environments.

The enhanced version of the managed strip also offers voltage and frequency metering. Hence the PDU is able to report the power factor, active and apparent power and main energy consumed in kWh. A calculation of carbon emission data (CO2 footprint) and the price estimation of consumed energy is also made.

INTELLIGENT POWER DISTRIBUTION UNITS – MANAGED (MONITORED PER OUTLET)

Code Input plug Length Type 1 outlet Qty Type 2

outlet Qty Rating MountingDimensions in mm

H W D

IP-DMA-008C3POM16 2 C20 x 1 C13 8 x x 16 A 1U 432 44 90

IP-DMA-308C9POM32 EN 60 309 3 m C19 8 x x 32 A 1U 432 44 90

INTELLIGENT POWER DISTRIBUTION UNITS - ENHANCED MONITORED (kWh)

IP-DEA-308C9POM32 EN 60 309 3 m C19 8 x x 32 A 1U 432 44 90

1 INPUT power cords for these models must be ordered separately (see below)2 “POM” stands for “per‑outlet‑monitored” i.e. each outlet is metered separately

INTELLIGENT POWER DISTRIBUTION UNITS – MANAGED (MONITORED PER STRIP)

Code Input plug Length Type 1 outlet Qty Type 2

outlet Qty Rating MountingDimensions in mm

H W D

IP-DMA-008C3 00 016 C20 x 1 C13 8 x x 16 A 1U 432 44 90

IP-DMA-021C33C916 C20 x 1 C13 21 C19 3 16 A 0U 1 778 44 56

IP-DMA-314C32C932 EN 60 309 3 m C13 14 C19 2 32 A 0U 1 245 44 56

IP-DMA-321C33C932 EN 60 309 3 m C13 21 C19 3 32 A 0U 1 778 44 56

IP-DMA-318C36C911 EN 60 309 3 m C13 18 C19 3 3x 16 A 0U 1 778 44 56

IP-DMA-318C36C922 EN 60 309 3 m C13 18 C19 3 3x 32 A 0U 1 778 44 56

INTELLIGENT POWER DISTRIBUTION UNITS - ENHANCED MANAGED (kWh)

IP-DEA-008C3 00 016 C20 x 1 C13 8 x x 16 A 1U 432 44 90

IP-DEA-314C32C932 EN 60 309 3 m C13 14 C19 2 32 A 0U 1 245 44 56

1 INPUT power cords for these models must be ordered separately

INTELLIGENT POWER MANAGED

Brackets for PDU

Code Options

DP-RP-VM-01 Brackets for mounting vertical 19" power distribution unit into PREMIUM/OPTIMAL frame

DP-RP-VM-02 Brackets for mounting vertical power distribution unit DP-RP-20-xx into PREMIUM/OPTIMAL frame

DP-RP-VM-06 Swivel brackets for mounting vertical PDU DP-RP-xx and IP-xxx into PREMIUM/OPTIMAL frame, set for 1 PDU

Possible position settings PDU with DP‑RP‑VM‑06

Page 5: INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)€¦ · technologies to address the needs of the high-density computing user. The range comprises power strips which feature either

www.conteg.comAll rights reserved, CONTEG © 2013

5

INPUT POWER CORDS FOR INTELLIGENT PDUs

Code In-out type Length

IP-C-C9SH25 IEC 320 C19 to Schuko (plug) 2.5 m

IP-C-C93 025 IEC 320 C19 to EN 60 309 (1×16 A) 2.5 m

IP-C-C9C225 IEC 320 C19 to IEC 320 C20 2.5 m

OUTPUT POWER CORDS FOR INTELLIGENT PDUs

Code In-out type Length

IP-C-C9C218 IEC 320 C19 to IEC 320 C20 1.8 m

IP-C-C3C405 IEC 320 C13 to IEC 320 C14 0.5 m

IP-C-C3C410 IEC 320 C13 to IEC 320 C14 1.0 m

IP-C-C3C418 IEC 320 C13 to IEC 320 C14 1.8 m

EN60 309 16A 1PH

IEC320 C13

Also known as C13

IEC320 C19

Also known as C19

UK

FRENCH

GERMAN

Output Socket Types

IEC320 C13

Also known as C13

IEC320 C19

Also known as C19

UK

FRENCH

GERMAN

Output Socket Types

IEC320 C19

IEC320 C13

Also known as C13

IEC320 C19

Also known as C19

UK

FRENCH

GERMAN

Output Socket Types

UK

IEC320 C13

Also known as C13

IEC320 C19

Also known as C19

UK

FRENCH

GERMAN

Output Socket Types

UTE

IEC320 C13

Also known as C13

IEC320 C19

Also known as C19

UK

FRENCH

GERMAN

Output Socket Types

SCHUKO

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

SCHUKO - FRENCH

UK

IEC320 C13

UK (BS 1 363)

IEC320 C14

IEC320 C20

SCHUKO – GERMAN

UTE – FRENCH

Input plug types

EN60309 16A

also known as EN309 16Aa 16 amp socket

EN60309 32A

also known as EN309 32Aa 32 amp socket

EN60309 63A

also known as EN309 63Aa 63 amp socket

IEC320 C14

Also known as C14

IEC320 C20

Also known as C20

SCHUKO -GERMAN

UTE - FRENCH

UK

OUTLET AND PLUG TYPES:

Note: Compatible with IP‑DMI and IP‑DMA

Note: Compatible with IP‑DMI and IP‑DMA

EN60 309 32A 1PH

EN60 309 16A 3PH EN60 309 32A 3PH

Dashboard screenshot of enhanced managed PDU:

Traditional basic PDUs, which are still produced and delivered, have part numbers starting with code DP-RP-xx. Conteg´s PDU part numbers for Intel-ligent and Basic power strips are set up in accordance with the following matrix.

IP-DMI-321C33C911*

An example of a correct product code

3 NUMBER OF OUTLET TyPE 1

2

INPUT PLUG TyPE(on the input power cord)

Code Options0 no cable, Inlet C20 onlyC IEC C203 EN 60 309

1

POWER STRIP TECHNOLOGy Code Options

BA BasicDMI Monitored (over IP)DMA ManagedDEI Enhanced MonitoredDEA Enhanced Managed

HOW TO READ PRODUCT CODE FOR INTELLIGENT POWER UNITS

IP - 1. - 2. 4. 5. 6. 7.

4

TyPE OF OUTLET TyPE 1 Code Options

UK UKSH SchukoUT UTE (French)C3 C13C9 C19

6TyPE OF OUTLET TyPE 2

Code OptionsC3 C13C9 C19

7

RATING OF STRIP Code Options

16 16 Amps32 32 Amps11 11 kW (3×16 A)22 22 kW (3×32 A)

3.

5 NUMBER OF OUTLET TyPE 2

* IP‑DMI‑321C33C911 indicates a Monitored Power Strip with plug EN 60 309, 21×C13 and 3×C19 outlets with 3×16 Ampere rating (11kW).