intelligent addressable conventional see what’s …see what’s possible now. low-profile wall and...

3
Intelligent Addressable PinPoint Ground-fault detection by module WireSaver feature enables use of existing or new solid or stranded fire wire for most retrofit applications Optional Ethernet port for local or remote diagnostics and programming Supports horn silence over two wires and UL 1971-compliant strobe synchronization Supports up to eight serial annunciators Dual-line DACT (dialer) enables monitoring, along with local or remote uploading and downloading and diagnostics Day/Night sensitivity detector adjustment Intelligent addressable technology engineered and designed expressly for small building applications... See what’s possible now. Exactly what you need – no more, no less! FX Series Intelligent FX-64 FX-1000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) support- ing up to 64 device addresses (any combination of detectors and modules) 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), each loop supporting up to 250 device addresses (125 detectors and 125 modules max.). Notification appliance circuits 2 Class B (Style Y), Class A (Style Z) optional 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 4 Class B (Style Y) or 2 Class A (Style Z) 6.0 A FWR total at 120/230 VAC 60 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 230 VAC, 50-60 Hz, 0.62 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Lit # K85005-0137 Automatic drift compensation extends detector life Precision UL 1971 signal synchronization and optional audible silence over just two wires Up to 7.5 amps available NAC power cuts equipment costs Fully integrated upload/download communications enables PC programming and off-premise monitoring Zone or NAC pairs convertible to single Class A circuits Combination Waterflow and Supervisory zones NACs programmable by zone and individually selectable for continuous, temporal or coded outputs, or Kidde synchronization protocol The simplicity of conventional wiring with valuable features found only among high-end systems... Advanced features available only with certain devices and panel configurations. Ask your Kidde distributor for details. Conventional FX Series Conventional Control Panels FX-10RD FX-5RD Initiating Device Circuits – IDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 Class A 0 1 2 3 4 5 0 1 2 Notification Appliance Circuits – NACs (Available combinations shown at right) Class B 4 2 2 0 2 0 Class A 0 1 1 2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each ,3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/60Hz... 2.2 amps 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA 104 mA 224 mA Panel Battery Charge Capacity (sealed lead acid only) Up to two 24 Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet Lit # K85005-0126 Powerful options at a great price! Free 24/7 Tech Support! Free 24/7 Tech Support!

Upload: others

Post on 25-Apr-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Intelligent Addressable Conventional See what’s …See what’s possible now. Low-profile wall and ceiling devices are available with white or red housings – and with optional

I n t e l l i g e n t A d d r e s s a b l e

• PinPoint™ Ground-fault detection by module

• WireSaver™ feature enables use of existing or new solid or stranded fire wire for most retrofit applications

• Optional Ethernet port for local or remote diagnostics and programming

• Supports horn silence over two wires and UL 1971-compliant strobe synchronization

• Supports up to eight serial annunciators

• Dual-line DACT (dialer) enables monitoring, along with local or remote uploading and downloading and diagnostics

• Day/Night sensitivity detector adjustment

Intelligent addressable technology engineered and designed expressly for small building applications...

See what’s possible now.

Exactly what you need – no more, no less!

FX Series Intelligent FX-64 FX-1000

Device loops 1 loop Class B or Class A (Styles 4, 6, 7) support-ing up to 64 device addresses (any combination of detectors and modules)

1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), each loop supporting up to 250 device addresses (125 detectors and 125 modules max.).

Notification appliance circuits 2 Class B (Style Y), Class A (Style Z) optional3.75 A FWR total at 120/230 VAC 60 Hz3.0 A FWR total at 230 VAC 50 Hz2.5 A FWR each max. per circuit

4 Class B (Style Y) or 2 Class A (Style Z)6.0 A FWR total at 120/230 VAC 60 Hz5.0 A FWR total at 230 VAC 50 Hz2.5 A FWR each max. per circuit

Primary power 120 VAC, 60 Hz, 1.3 A max.230 VAC, 50-60 Hz, 0.62 A max.

120 VAC, 60 Hz, 2.0 A max.230 VAC, 50-60 Hz, 0.97 A max.

Base panel current standby 155 mA 172 mA

Base panel current alarm 204 mA 267 mA

Input zones 16 max. 32 max.

Lit # K85005-0137

• Automatic drift compensation extends detector life

• Precision UL 1971 signal synchronization and optional audible silence over just two wires

• Up to 7.5 amps available NAC power cuts equipment costs

• Fully integrated upload/download communications enables PC programming and off-premise monitoring

• Zone or NAC pairs convertible to single Class A circuits

• Combination Waterflow and Supervisory zones

• NACs programmable by zone and individually selectable for continuous, temporal or coded outputs, or Kidde synchronization protocol

The simplicity of conventional wiring with valuable features found only among high-end systems...

Advanced features available only with certain devices and panel configurations. Ask your Kidde distributor for details.

C o n v e n t i o n a l

FX Series Conventional Control Panels FX-10RD FX-5RDInitiating Device Circuits – IDCs (Available combinations shown at right)

Class B 10 8 6 4 2 0 5 3 1Class A 0 1 2 3 4 5 0 1 2

Notification Appliance Circuits – NACs (Available combinations shown at right)

Class B 4 2 2 0 2 0Class A 0 1 1 2 0 1

Power Supply 7.5 amps total 4.25 amps totalNAC Voltage Rating 24 VfwrMaximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each ,3.5 amps totalAC Input 120 Vac 60 Hz... 230 Vac 50/60Hz...

2.2 amps 1.1 amps

1.25 amps 0.6 amps

Base Panel Current Draw Standby... Alarm...

128 mA 242 mA

104 mA 224 mA

Panel Battery Charge Capacity (sealed lead acid only) Up to two 24 Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet

Lit # K85005-0126

Powerful options at a great price!

Free 24/7 Tech Support! Free 24/7

Tech Support!

Page 2: Intelligent Addressable Conventional See what’s …See what’s possible now. Low-profile wall and ceiling devices are available with white or red housings – and with optional

See what’s possible now.

Low-profile wall and ceiling devices are

available with white or red housings – and with

optional “FIRE” markings.

G1T

Wall Signal Trim PlateLit # K85001-0573

Ideal for covering openings left behind during retrofits. Red or white models available, with or without “FIRE” markings.

EG1M

Signal MasterLit # K85001-0545

Snap-on or pan-el-mount modules bring UL 1971 compliance to any listed fire alarm control panel, and pro-vide independent horn control over two wires.

Low-profile ceiling devices are rated for wall or ceiling

mount applications.

Field-configurable light and sound output means fewer devices to stock, and greater flexibility.

EBPS Series

Booster Power SuppliesLit # K85005-0125

Booster Power Supplies that support Kidde low profile notification appliances and offer strobe synchronization while providing in-dependent horn control over a single pair of wires. Available in 6.5 and 10 Amp models.

Signals with cost-saving

innovations and compact,

unobtrusive good looks!

ANS series

Audio Notification SystemLit # K85001-0587

Self-contained systems available in 25, 50, or 100 Watt models. Include an amplifier, tone generator, digital message repeater (DMR), and supervisory interface. Compatible with Kidde field-configurable speakers and speak-er-strobes.

EG4-S Series

Wall Speaker-strobesLit # K85001-0642

25- and 70-Volt 520 Hz capable models with selectable wattage taps and field-configurable multi-candela light output settings.

The FX “Running Man” icon meets code,

overcomes language barriers, and eliminates

lens marking headaches.

Speak to your Kidde distributor to learn about the full range of devices and accessories now available.

EGC Series

Ceiling StrobesLit # K85001-0557

Multi-candela strobes with light output of up to 177 cd.

EGC-S Series

Ceiling SpeakersLit # K85001-0641

25- and 70-Volt 520 Hz capable models with selectable wattage taps.

Kidde notification appliances com mand attention and exceed regulatory

require ments with innovations like wall-penetrating audible tones and Full-

Light™ strobe tech nology. Add our ANS system to any Kidde installation and

offer high-end voice audio capabilities.

About the size of a deck of

playing cards!

EGC-H Series

Ceiling Horn-StrobesLit # K85001-0559

Horn-strobes include field-configurable multi-candela strobes with light output of up to 177 cd.

H o r n s , S t r o b e s & C h i m e s V o i c e A n n u n c i a t i o n

Fire alarm solutions now as easy to buy as they are to install. Look for our distinctive information-packed boxes at an electrical wholesaler near you!

Page 3: Intelligent Addressable Conventional See what’s …See what’s possible now. Low-profile wall and ceiling devices are available with white or red housings – and with optional

FX Series

Intelligent FX Series DetectorsLit # K85001-0592

Optical, fixed tempera-ture, or rate of rise and combination optical/fixed temperature models available.

PDD Series

Intelligent Duct Smoke DetectorLit # K85001-0613

Intelligent duct detec-tion with an exclusive space-saving design.

Exclusive replaceable optical chambers breathe new life into Kidde FX Series detectors. Keep a ready supply on-hand at all times and leave every jobsite knowing a dirty detector won’t cause a false alarm any time soon.

R-Series

Remote AnnunciatorsLit # K85005-0128

LCD and LED annunciators for status indication and optional common controls. LED-based expander available. All models include an internal sounder. Red or white housings.

FX-270, FX-278

Intelligent Manual StationsLit # K85001-0612

One stage and two stage models available.

FX Series

Intelligent Addressable Input/Output Modules

Lit # K85001-0611

Optional panel-mounted modules include Dual and single Input, Class A, Class A/B Two-Wire, Waterflow/Supervisory, NAC, Contact Relay, and Fault Isolator.

PinPoint™

... ground fault detection

so precise that it actually

specifies the module where a

wiring problem has occurred!

I n t e l l i g e n t I n i t i a t i n g

700 Series

Self-Diagnostic Smoke Detectors Lit # K85001-0598

Two- and four-wire optical, fixed tempera-ture, rate-of-rise, and combination models available. Optional re-mote test input, trouble LED output, and alarm relays.

EC-50R/-100R

Reflective Beam DetectorLit # K85001-0560

Models with one or four reflectors. Optional test station available.

276/277 Series

Single-Action Fire Alarm StationsLit # K85001-0183

Models with screw terminals or wire leads, SPST or DPST, and optional key reset.

279M/103 Series

Dual-Action Fire Alarm StationsLit # K85001-0227

Non-coded SPST or DPST models. Optional hex key reset.

Built-in drift compensation

dramatically extends the

time between cleanings

– and if cleaning is ever

necessary, our innovative

optical chamber takes

just seconds to replace!

Replaceable optical

chamber!

SuperDuct Series

Duct Smoke DetectorsLit # K85001-0583

Two- and four-wire models available in an exclusive space-saving design.

270 Series

Conventional Fire Alarm StationsLit # K85001-0303

Double and single pole models available with terminals or wire leads.

30-3013

Explosionproof Optical Smoke DetectorLit # K85001-0645

FM Approved for smoke detection in Class I, Division 1 hazardous locations.

MPSR1-D45WX

Hazardous location Fire Alarm StationLit # K85001-0614

Our exclusive replaceable

optical chamber makes

detector cleaning a

snap – literally!

C o n v e n t i o n a l I n i t i a t i n g FX S

eries > Fire A

larm C

ontrol Panels

Technology that saves lives.