insulfoil - fanosa · 2015-12-02 · insulfoil c) maximum loads, weight and thermal properties 1....

8
INSULFOIL MANUAL INSULPANEL 5 OF 7 INSTALLATION INSULFOIL INSULPANEL ROOF INSULPANEL WALL INSULPANEL COLD ROOMS TECHNICAL ASSISTANCE

Upload: others

Post on 22-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

INSULFOIL

MANUAL INSULPANEL 5 OF 7

INSTALLATIONINSULFOILINSULPANEL ROOFINSULPANEL WALLINSULPANEL COLD ROOMSTECHNICAL ASSISTANCE

Page 2: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

CHARACTERISTICS

01

The Insulfoil belongs to the Insulpanel family; it is a panel with the components of the Insulpanel classic but substitutes one of the sheets metal (interior or exterior ) for a polypropylene-based covering, reinforced with a fiberglass mesh; that is, a foil-typecovering.

Insulfoil Wall

Insulfoil Roof

Page 3: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

02

Insulfoil is available in two versions: Insulfoil Roof and Insulfoil Wall.

FEATURES INSULFOIL

FIRE TEST

Page 4: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

A) Dimensions

B) Joints

Unlike Insulpanel, Insulfoil is available in pieces 30ft in length (for panels with a thickness of 4” or less), up to 36 ft in length (for panels with a thickness of 4” or more). The effective width for each panel is 40 in for roofs and 46 in for walls.

On its exterior side for walls or roofs, the Insulfoil’s joints are similar to those in the Insulpanel; and on its interior side, it has an excess of foil, which folds to the inside of the joint between each panel.

03

A

B

C

Joint details

Longitudinal overlap

Insulfoil

Sheet metal

On the transverse overlap, the joint is applied on-site in the same way as the Insulpanel, with the added convenience of cutting the foil film instead of a sheet metal

Page 5: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

C) Maximum loads, weight and thermal properties

1. MAXIMUM LOAD CHARTS FOR THEINSULFOIL ROOF

04

T

Calculation conditions:

1.- Steel’s yield stress = 2600 kg/cm² (37ksi). 2.- Maximum allowed deflection of L/240. 3.- Design based on the allowed stress criteria according to “Design of Foam Filled Structures” by John A. Hartsock and on the AISI Cold-Formed Steel Specification 1996. 4.- For wind loads, the stress was increased by 1/3 above the values of the allowed stress, as long as this load is not lower than the one required by dead and live loads, or by maximum deflections. 5.- It is considered that the section’s total effectiveness is reduced (effective S).

Page 6: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

2 . MAXIMUM LOAD CHARTS FOR THEINSULFOIL WALL

Calculation conditions:1.- Steel’s yield stress = 2600 kg/cm² (37ksi). 2.- Maximum allowed deflection of L/180.3.- Design based on the allowed stress criteria according to “Design of Foam Filled Structures” by John A. Hartsock and on the AISI Cold- Formed Steel Specification 1996. 4.- For wind loads, the stress was increased by 1/3 above the values of the allowed stress, as long as this load is not lower than the one required by dead and live loads, or by maximum deflections. 5.- The values of the maximum loads are determined by the compression stress on the face.

05

3. INSULFOIL’S WEIGHT

M

Page 7: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

06

FANOSA provides the following information as a backup for the application of all products. FANOSA cannot be held responsible for any product misuse. Likewise, to verify applicability it is recommended that, at the client’s expense, the advice of a specialist be obtained. FANOSA under no circumstances will be responsible for the installation and/or accessories used for installation of products sold. FANOSA expressly disclaims all warranties, express or implied. By making this information available FANOSA is not providing professional services and assumes no duty or liability with respect to any person who makes use of such information. Similarly, FANOSA would not be liable for any claim, demand, injury, loss, expense, cost, legal fees or liability of any kind, in any way arising out of or connected with the use of the information contained in this publication, whether or not such claim, demand, injury, loss, expense, cost, legal fees or liability results directly or indirectly from any act or omission of FANOSA. Any party using the information contained in this manual assumes all liability arising from such use. Because there are risks associated with the handling, installing or use of steel and accessories, we recommend that the parties involved in the handling, installing or use review all applicable material safety data sheets from the manufacturer, as well as rules and regulations from the Secretary of Labor and Social Security and other government agencies having jurisdiction over such handling, installing or use, and other relevant building practices publications.

Issue 01, August 2014 FANOSA reserves the right to change, without notice, the data hereof.

Page 8: INSULFOIL - FANOSA · 2015-12-02 · INSULFOIL C) Maximum loads, weight and thermal properties 1. MAXIMUM LOAD CHARTS FOR THE INSULFOIL ROOF 04 T Calculation conditions: 1.- Steel’s

INSULFOIL

www.fanosa.com 619 6775706