instruments model r6200 · 2018. 5. 24. · the r6200 has the ability to record up to 99 points...

12
reedinstruments www com Model Instruction Manual INSTRUMENTS WBGT Heat Stress Meter R6200 REED Instruments 1-877-849-2127 | [email protected] | www.reedinstruments.com

Upload: others

Post on 02-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • reedinstrumentswww com

    Model

    InstructionManual

    INSTRUMENTS

    INSTRUMENTSWBGT Heat Stress Meter

    R6200

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 2INSTRUMENTS

    INSTRUMENTS

    Table of Contents

    Features .......................................................................................................2

    Specifications .......................................................................................... 3-4

    Product Description ................................................................................ 4-5

    Operating Instructions ........................................................................... 6-12

    Features• Measuresambienttemperature,humidity,wetbulbtemperature,blackglobetemperature,WBGT(wetbulbglobaltemperature),heatstressindex,dewpointandpressure

    • HeatStressIndexmeasureshowhotitfeelswhenhumidityiscombinedwithtemperature,airmovementandradiantheat

    • BlackGlobeTemperature(GT)monitorstheeffectsofdirectsolarradiationonanexposedsurface

    • In/OutfunctiondisplaystheWBGTvaluewithorwithoutdirectsunexposure

    • Multi-linebacklitLCDdisplaysimultaneouslydisplays4measurements• Maximum,Minimum,AverageandDataHoldfunctions• Internalmemorystoresupto99measurements• Userselectableunitofmeasure(°For°C)• UseradjustableWBGTthresholdalarm(audible)• Tripodmountforlong-termmonitoring• Lowbatteryindicatorandautoshutoff• Includesbatteries

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 3INSTRUMENTS

    INSTRUMENTS

    SpecificationsTemperatureMeasuringRanges AirTemperature:32to122°F(0to50°C) BlackGlobe:32to176°F(0to80°C) WBGT(Indoor):59to138.2°F(15to59°C) WBGT(Outdoor):59to132.8°F(15to56°C)Accuracy AirTemperature:±1.1°F(±0.6°C) BlackGlobe:±0.6°C(20~50°C),other±1°C WBGT(Indoor):±2.7°F(±1.5°C) WBGT(Outdoor):±3.6°F(±2°C)Resolution 0.1°F/°CHumidityMeasuringRanges 0-99.9%RHAccuracy(@25°C) 10%to70%RH:±3% RestofRange:±5%Resolution 0.1%RHBarometricPressureMeasuringRange 300-1100hPa(inHg,mmHgswitchable)Accuracy ±1.5hPaResolution 1hPa,0.1inHg,0.1mmHgGeneralSpecifications DewPoint/WetBulbCalculation YesResponseTime 1secDisplay LCDBacklight Yes(non-condensing)DataHold YesMin YesMax YesAverage YesInternalMemory Yes,upto99measurements

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 4INSTRUMENTS

    INSTRUMENTS

    AutoShut-Off Yes(after15mins/off)UserAdjustableWBGTAlarm Yes(audible)TripodMountable YesLowBatteryIndicator YesPowerSupply 4xAAAbatteries,OptionalACAdapterProductCertifications CE,RoHSOperatingTemperature 32to122°F(0to50°C)OperatingHumidity

  • reedinstrumentswww com 5INSTRUMENTS

    INSTRUMENTS

    Key Pad

    Button Description

    PWRPowerinstrumentonoroff/Activateorinactivateaudiblebeeping

    HOLDFreezecurrentmeasurementsondisplay/Increasedigit/Scrollforward

    BKLTTurnbacklightonoroff/Decreasedigit/Scrollbackwards/Changepressureunit

    MAX/MIN ReviewMax,Min,andAveragereadings

    MODE

    EnterWBGTalarmvaluesetting/Togglebetweentemperaturemodes:

    GlobalTemperature(GT)

    WetBulbGlobalTemperature(WBGT)

    Heatindex(HI)

    DewPoint(DP)

    WetBulbTemperature(WB)

    SETChangepressurevalue/Recordmeasurementstomemory

    UNITToggleTemperatureunitbetween°Cand°F/Selectdesireddigitwhensettingalarmthreshold

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 6INSTRUMENTS

    INSTRUMENTS

    Operating Instructions

    POWER ON/OFFPressthe”PWR”buttontoturnthemeteron,pressandholdfor2secondstoturnthemeteroff.

    Whenthemeterispoweredon,theLCDdisplaystheWBGTmodeandthepreviouslyselected“IndoororOutdoor”WBGTmeasurementmode.Shortlyafter,abeepwillsoundandtheinstrumentwillbegintakingmeasurements.

    MAX/MIN/AVGPressthe MAX/MIN buttontocyclethedisplaythroughtheMaximum,Minimum,AveragemeasurementsofAmbientTemperature,GlobalTemperatureandRelativeHumiditysincetheinstrumentwaspoweredon.

    PressandholdtheMAX/MINbuttonuntil“CLr” appearsonthebottomofLCD.Theinstrumentwillautomaticallyreturntonormalmeasurementmodeoncethereadingshavecleared.

    INDOOR/OUTDOOR Temperature MODE SELECTIONWheninthe WBGTmode,pressandholdtheUNITbuttontotogglebetweenindoororoutdoortemperature.Theinstrumentautomaticallycalculatesthemeasurementusingthefollowingparameters:

    a. OutdoorformulaWBGT=0.7Tw(wetbulbtemp)+0.2Tg(globetemp)+0.1Td(airtemp.)

    b. IndoorformulaWBGT=0.7Tw(wetbulbtemp)+0.3Tg(globetemp)

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 7INSTRUMENTS

    INSTRUMENTS

    SWITCH UNIT OF TEMPERATURE °C/°FPresstheUNITbuttontoswitchbetween°Cand°F.

    SWITCH UNIT OF PRESSUREPresstheBKLTbuttontochangethepressuremeasuringunit.(hpa-->inHg-->mmHg).

    TEMPERATURE DISPLAY MODESPresstheMODEbuttontotogglethroughtheGT(Globetemperature)-->WBGTtemperature-->HI(Heatindex)-->DPT(Dewpoint)-->WB(Wetbulbtemperaturemeasurements).

    NOTE: Verify the meter is not displaying the MAX/MIN/AVG. If so, press the MAX/MIN button until the icons have disappeared.

    FREEZE READINGPresstheHOLDbuttonundernormalmeasurementanda“HLD” icon appearsonthedisplaytoindicatethatthemeterisinDataHold.Whenthisfeatureisturnedon,theonlyfunctionalityavailableistheabilitytoswitch between units of pressure, temperature and scrolling through the temperature display modes“GT/WBGT/HI/DPT/WB”.

    AUTO-POWER OFFThemeterwillautomaticallyturnoffwhennotinuseforaperiodof15minutes.TodisabletheautopowerofffunctionpresstheHOLD and PWR buttonsatthesametime.TheLCDwillmomentarilydisplay“n” indicating theauto-powerofffeatureisdisabled.

    BACKLIGHT FUNCTIONPressandholdthe“BKLT”buttontoactivateorinactivatebacklightfunction.

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 8INSTRUMENTS

    INSTRUMENTS

    INTERNAL MEMORYThe R6200 has the ability to record up to 99 points internally.

    a. PresstheSETbuttontosaveareading(Temp.RH).

    b. TheRECiconshowswilldisplaynexttothetemperaturereadingandrecordnumbershowsonthebottomofLCDfor2seconds.

    To recall recorded data:

    a. PressandholdtheMODEbuttontoreviewmemoryTemperature,RHandrecordednumber.

    b. KeeppressingtheHOLDbuttontoreviewnextdataorpressandholdtheBKLTbuttontoreviewthelaststoreddataentry.

    c. PresstheMODEbuttontwice,toescapememoryfunction.d. Underdatarecallmode,pressandholdtheSETbuttontoclearthe

    memory.LCDwillshow“---”.

    WBGT AUDIBLE ALARM THRESHOLD SETTING(The default WBGT temperature alarm value is set at 31°)

    a. PressandholdtheMODEbuttonfor2secondsandthemeterwillentermemoryrecallmode.

    b. PressandholdMODEbuttonagaintoenterWBGTalarmmode.

    c. PresstheHOLDbuttontoincreasethevalue,presstheUNITbuttontoselectthenextdigit.

    d. PresstheBKLTbuttontodecreasethevalue,presstheUNITbuttontoselectthenextdigit.

    e. Oncethealarmisselected,pressandholdtheMODEbuttontosavethevalueandreturntonormalmeasurementmode.

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 9INSTRUMENTS

    INSTRUMENTS

    TURN ON/OFF ALARM FUNCTIONAftersettingupthethreshold,pressthePWRbuttonandthebelliconwilldisplayonthescreenindicatingthealarmisactivated.PressthePWR buttonagaintodisablealarmfunction.

    GLOBAL TEMPERATURE/AMBIENT TEMPERATURE/HUMIDITY OFFSET FUNCTIONItisrecommendedthatthisunitbecalibratedonceayeartoensuremeasurementsstaywithinmanufacturer’sspecifications.Inthecasethatauserwouldliketoperformself-verificationwithatrustedcalibrationsourcethefollowingoffsetprocedureshavebeenprovided.

    Toentertheoffsetmode:

    a. PowerOFFthemeter.b. PressandholdtheMODE and BKLTbuttons.c. PressthePOWERbuttonuntilthescreenshowsall3parametersin

    “0.0”,thenreleasetheMODE+BKLTbuttons.NOTE: To offset temperature in °F, hold MAX/MIN and press the POWER button to select °C or °F.

    Globe temperature offset

    • HoldtheUNITbuttonandpresstheHOLD buttonatthesametimetoincreasethevalue.

    • HoldtheUNITbuttonandpresstheBKLTbuttonatthesametimetodecreasethevalue.

    • PresstheMODE and POWERbuttonstosavethevalue.

    • Repowerthemetertoreturnnormalmeasurementmode.

    Ambient temperature offset

    • HoldtheSETbuttonandpresstheHOLDbuttonatthesametimetoincreasethevalue.

    • HoldtheSETbuttonandpresstheBKLT buttonatthesametimeto

    buttonandthebellicon

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 10INSTRUMENTS

    INSTRUMENTS

    decreasethevalue.• PresstheMODE and POWERbuttonstosavethevalue.• Repowerthemetertoreturnnormalmeasurementmode.Relative Humidity Offset

    • HoldtheMAX/MINbuttonandpresstheHOLDbuttonatthesametimetoincreasethevalue.

    • HoldtheMAX/MINbuttonandpresstheBKLTbuttonatthesametimetodecreasethevalue.

    • PresstheMODE and POWER buttonstosavethevalue.• Repowerthemetertoreturnnormalmeasurementmode.

    Pressure Offset Functiona. PressandholdtheSETbuttonuntilthe

    LCDshows“0.0 hpa”.b. ToincreasethevaluepresstheHOLD

    button.c. TodecreasethevaluepresstheBKLTbutton.d. PressandholdthePOWERbuttontosavethesetvalue.e. TheLCDwilldisplay“SAVE”andreturntonormalmeasurement

    mode.NOTE: The compensation range is ±3 hpa.

    ERROR CODE

    Code Description

    Er1: Sensorfailed.

    Er2: Outofmeasuredrange.

    Low Battery IndicatorWhenthebatteryislowtheLCDwilldisplay“bAt”.Itisrecommendedtostopuseimmediatelyandreplacethebatteries.

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 11INSTRUMENTS

    INSTRUMENTS

    Forserviceand/orinformationonthisoranyotherREEDproduct,[email protected].

    Notes __________________________________________

    ________________________________________________

    ________________________________________________

    ________________________________________________

    ________________________________________________

    ________________________________________________

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com

  • reedinstrumentswww com 12INSTRUMENTS

    INSTRUMENTS

    REED Instruments1-877-849-2127 | [email protected] | www.reedinstruments.com