Sr. No. Units
I General & Process
1 Process Details
Average flow
Peak Factor
Peak FlowRaw sewage BOD5 at 20 c
Raw sewage TSS
Treated sewage BOD
Treated sewage TSS
2
Total Head loss (m) in STP (from stilling chamber of STP to
Chlorine Contact Tank)
3 Total land area (hectare) proposed for STP
II Raw Sewage Pumping Station
(a) Receiving Chamber
1 Design Peak Flow
2 No of Units
3 Detention Period
4 Liquid Depth (m)
5 Length (m)
6 Width (m)
7 Water Level (m)
(b) Coarse Screen Channels
1 Design Peak Flow
2 No. of Units (working + stand by)
3 Clear Spacing Through bars
4 Width of Channel (m)
5 Length of Channel (m)
6 Liquid Depth (m)
7 Upstream Water Level (m)
8 Downstream Water Level (m)
9 Head Loss (mm)
(d) Wet Well Pump House
(i) Wet Well Pump House
1 Design Peak Flow
2 No of Units
3 Detention Period
4 Liquid Depth (m)
5 Length (m)
6 Width (m)
-
7/30/2019 Instrumentation Data Sheets
2/28
7 Water Level (m)
(ii) Pump House
Size (m*m)
Height (m)
Sewage Treatment PlantStilling Chamber
As required
Number
Retention Time
Material of Construction
Free Board, mm
Top
Steps in Chamber/Sump
Bar Screens (fine)
As required
Number
Type
Average Flow
Peak Factor
Velocity at Peak Flow Manual Screen
Bar Size (Manual)
Bar Size (Mechanical)
Clear Spacing (Mechanical)Material of Construction
Size of channels
Width,m (Manual)
Length,m
Liquid Depth (m)
Free Board, mm
Screen
Manual Screen
Clear Spacing (Manual)
Material of Construction
Velocity at Peak Flow Manual Screen
Bar Size (Manual)
Make Manual
Mechanical Screen
Clear Spacing (Manual)
Material of Construction
Velocity at Peak Flow Manual Screen
Bar Size (Manual)
Make Mechanical
-
7/30/2019 Instrumentation Data Sheets
3/28
Screen Conveyor to be Provide
Mechanical Grit Separator
As required
Number
TypeSize of Grit
Specific Gravity of Grit
Retention Time (Peak flow)
Material of Construction
Size
Free Board, mm
Velocity Control Device
SBR Basins with Biological selector zone
As required
System Proposed
Design Flow
Inlet BOD (mg/lit)
Inlet SS (mg/lit)
Outlet BOD (mg/lit)
Outlet SS (mg/lit)
Free Board, mm
No of SBR Tanks (basin)
Tank Material of Construction
Hydrolic Retention timeDetails of Basins
Length/breadth/ of each basin
Side Water Depth (m)
Volume of each basin
MLSS (mg/lit)
Oxygen Uptake Rate (OUR) Control Proved yes/No-nos
PLC and SCADA provided
Aeration System / Diffusers
Type
Material of Diffuser
Dia and Length of each Diffuser
Air Flow through each diffuser (Nm3/hr)
Total nos of Diffuser
Make
Air Blowers
Air Required (m3/hr)
Type of AIR Blowers
Make
No of Blowers
-
7/30/2019 Instrumentation Data Sheets
4/28
Capacity of Blower (Nm3/hr)
Head of Blower (kg/cm2)
Blower RPM/ Aerator RPM
Motor Rating (in kw)
Decanting Mechanism
Decanting Rate of Treated Sewage (m3/hr)
TypeSpeed
Decanting Capacity of each Decanter (MLD)
No of Decanters per Basin (No)
Operating hrs of each decanter hrs
Motor Rating (in kw)
No of decanters with VFD operation (No)
Material of Construction
Instrument for Air Measurement
Type
Nos
Make
Instrument Pressure indicator
Type
Nos of Pressure
Make of Pressure Guage
Disinfection
As required
Disinfectant
Chlorine Dosage Required
Type
Total Chlorine Required
Chlorine shed and neutra pit size
Material of Construction of chlorination shed and neutra pit
Contact Tank
Retention Time, min.
Size- Chlorine Contact Tank
As required
Numbers
Width / Diameter, m
Length, m
Liquid Depth, m
Free Board, mm
Tank Material of Construction
Chlorine Contact Arrangement
-
7/30/2019 Instrumentation Data Sheets
5/28
Chlorine Tonners
Booster Pumps- Gas Chlorination
As required
Numbers
TypeCapacity
Head
Material of Construction
Make of Pump
Instruments- Pressure Indicator
Type
No of Pressure Guage
Make of Pressure Guage
Sludge Sump
As required
Dry Sludge Quantity
Specific Gravity of Sludge
Solid consistency in Sludge
Volume of Sludge
Retention Time, hours
Size-Sump
Quantity
Length, m
Width, mLiquid Depth, m
Free Depth, m
Tank Material of Construction
Mixing in Sump
Type
Mixing Requirment, m3/hr/m3
Liquid Depth, m
Air Grid Material of Construction
Sludge sum Air Blowers
Type of air blower
Make
No of working blowers
No of stand by blowers
Capacity of blowers (Nm3/hr)
Head of Blower (kg/cm2)
Motor Rating (in kw)
Return Sludge Pump
-
7/30/2019 Instrumentation Data Sheets
6/28
As required
Numbers
Type
Capacity
Head
Material of Construction
Solid SizeMotor Rating (in kw)
Make of Pump
Surplus Activated Sludge Pump
As required
Numbers
Type
Capacity
Head
Material of Construction
Solid Size
Motor Rating (in kw)
Make of Pump
Centrifuge Feed Pumps
Pumps
As required
Numbers
Type
CapacityHead
Material of Construction
Make of Pump
Instruments- Pressure Indicator
Type
No of Pressure Guage
Make of Pressure Guage
Sludge Dewatering Equipment
Type
As required
Total Sludge (Dry basis)
Working hrs/day
Nos.
Sludge Consistency
Sludge Volume
Solids Loading
Dewatered Sludge Consistency
Dewatered Sludge Quantity
-
7/30/2019 Instrumentation Data Sheets
7/28
Centrate Quantity
Material of Construction
Make
Dewatering Polyelectrolyte Dosing System
As requiredQuantityb of Polymer
Chemical Solution %
Volume of Chemical Solution
Service time, hrs
No of Tank
Numbers
Length, m
Width, m
Liquid Depth, m
Free Depth, m
Tank Material of Construction
A Mixer- Dewatering Polyelectrolyte Dosing Tank
As required
Numbers
Type
Capacity
Material of Construction
Make of Mixer
B Dewatering Polyelectrolyte Dosing Tank
As required
Numbers
Type
Capacity
Material of Construction
Make of Pump
Raw Sewage Submersible Pumps
As required
Numbers
Type
Capacity
Material of Construction
Casing
Impeller
Shaft
-
7/30/2019 Instrumentation Data Sheets
8/28
Bearing
Solid Size
Motor Rating (in kw)
Make of Pump
Diesel Generating Set
As required
Numbers
Capacity
Type
Make of Alternator
Make of Engine
Type of Supply
-
7/30/2019 Instrumentation Data Sheets
9/28
Details to be furnished by the bidder
-
7/30/2019 Instrumentation Data Sheets
10/28
As proposed by Bidder
As proposed by Bidder
-
7/30/2019 Instrumentation Data Sheets
11/28
As proposed by Bidder
As proposed by Bidder
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
-
7/30/2019 Instrumentation Data Sheets
12/28
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to SpecifyBidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
Bidder to Specify
As proposed by Bidder
free chlorine
Bidder to Specify in mg/lit to achive totalColiform count as required
Gas chlorination-chlorination with safety
equipment like canister mask, gloves,
goggles, safety shower, emergency repair
kit ect.
As proposed by Bidder
1
-
7/30/2019 Instrumentation Data Sheets
13/28
As proposed by Bidder
Bidder to Specify (W+S)
Bidder to Specify
Bidder to Specify
As proposed by Bidder
-
7/30/2019 Instrumentation Data Sheets
14/28
As proposed by Bidder
Bidder to Specify (W+S)
Bidder to Specify
Bidder to Specify
Bidder to Specify
As proposed by Bidder
Bidder to Specify (W+S)
Bidder to Specify
Bidder to Specify
Bidder to Specify
As proposed by Bidder
Bidder to Specify (W+S)
Bidder to Specify
Bidder to SpecifyBidder to Specify
Solid Bowl Centrifuge
As proposed by Bidder
-
7/30/2019 Instrumentation Data Sheets
15/28
As proposed by Bidder
As proposed by Bidder
Bidder to Specify (W+S)
As proposed by Bidder
As proposed by Bidder
-
7/30/2019 Instrumentation Data Sheets
16/28
As proposed by Bidder
-
7/30/2019 Instrumentation Data Sheets
17/28
Chemical Dosing
Chlorine Dosing for Coliform Removal to meet as per design
Dose Point
Chemical Proposed to be
Used Dose in mg/l Purity, %
At the inlet of Chlorinecontact Tank Gas Chlorine * *
At the Inlet of Centrifuge Dewatering Polyelectrolyte
*-Bidder to Specify
Sheds & Buildings
Room for Blowers Bidder to Specify
Building for Administration
& Laboratory MCC Panel
Room with Toilet Min. 200 m2
Sludge Pump and Pump
House Bidder to Specify
Centrifuge Shed Bidder to Specify
MCC Panel room/ L.t. room/
H.T. room Bidder to Specify
Note: As space available for Treatment plant and sewage pumping station is limited, some of the u
-
7/30/2019 Instrumentation Data Sheets
18/28
Quantity in kg/d
Chemical Solution Required per
annum
* *
nits mentioned above may be accommodateed in double story building.
-
7/30/2019 Instrumentation Data Sheets
19/28
1 Safety Equipment Details to be Furnished by the bidder
Air Breathing Apparatus
Instant Action Resuscitator
Safety Cloths
Gas Fronted Cabinet
Emergency Shower with Eye Wash Fountain
Emergency Repair kit for TonnerResidual Chlorine Test kit
2 Others
Trunnions/Roller Support
Suspended Weigh Scale
Lifting Beam for toner
3 Leak Absorption System
3.1 Half Hood
Make
Size
MOC
Quantity (Nos.)
3.2 Caustic Solution Tank
Make
Size
MOC
Quantity (Nos.)
3.3 Caustic Solution Pump
Make
Type
Capacity
Head (m)MOC
Casing
Impeller
Shaft
Drive Details:
Make
Type
Rating
3.4 Air Blower
Make
Type
Capacity
Head (m)
MOC
Quantity (Nos.)
Casing
Impeller
Shaft
Drive Details:
-
7/30/2019 Instrumentation Data Sheets
20/28
Make
Type
Rating
3.5 Diffuser
Make
Size/Rating
MOCRating
Quantity (Nos.)
3.6 Caustic Solutin Piping
3.6.1 Ball Valve
Size
MOC
End Connection
Quantity (Nos.)
3.6.2 Non Return Valve
Size
MOC
End Connection
Quantity (Nos.)
3.6.3 Y-strainer
Size
MOC
End Connection
Quantity (Nos.)
3.6.4 Pressure Gauge
Make
RangeType
End Connection
Quantity (Nos.)
Piping & Valve Schedual
The bidder to fill in the following pipeline schedual-without the pipeline schedual the bid shall be co
Pipe & Fittings
From To
-
7/30/2019 Instrumentation Data Sheets
21/28
Valves
Application Type/Code
-
7/30/2019 Instrumentation Data Sheets
22/28
-
7/30/2019 Instrumentation Data Sheets
23/28
sidered as non-responsive. Use additional sheets if required.
Type/Code Material of Construction Remarks
-
7/30/2019 Instrumentation Data Sheets
24/28
Material of Construction Remarks
-
7/30/2019 Instrumentation Data Sheets
25/28
Instrumentation Schedual
DATA SHEETS FOR INSTRUMENTATION
Sl. No. DESCRIPTION VALVE
A PRESSURE GAUGE
1 GENERALa Tag No.
b Quantity
c Service
d Type
e Range
f Pressure (Nor./Max.) kg/cm2g
g Temprature (Nor./Max.) OC
h Case Material
i Bezel Gasket
j Zero Adjustment
k Window Material
l Accuracy
m Below Out Protection
n Over Range Protection
2 DIAL
a Size
b Color
3 ELEMENT
a Sensor
b Sensor Material
c Movement Material4 CONNECTION
a Gauge end connection
b Connection Location
c Process Connection
d Rating Connection
5 ACESSORIES
a Snubber/Syphon
b Snubber/Syphon conn.
c Snubber/Syphon material
6 DIAPHRAGM SEAL
a Primary Element
b Primary Element Material
c Other Wetted Part
d Upper Body Material
e Lower Body Material
f Seal Fluid
7 REMARKS
a Enclosure Protection
b Mounting
-
7/30/2019 Instrumentation Data Sheets
26/28
c Area Classification
d Ambient Temp.
B LEVEL SWITCH
1 GENERAL
a Tag no.
b Quantity
c Serviced Measuring Range
e Mounting
2 ENLOSURE PROTECTION
a Enclosure Protection
b Enclosure Protection Material
c Conn. Size
d Flange Material
e Flange Rating
f Power Supply
g Switch Relay type
h Qty
i Contact Rating
j Cable Entry Single/Double
k Time Delay On & Off
l Fail Safe Setting
m Prob/Electrode material
n Ref. Electrode Material
3 DESIGN DATA
a Fluid
b Pressure (Nor./Max.) kg/cm2g
c Temprature (Nor./Max.) OCd SP. Gravity
e Probe Length
f Ref. Electrode Material
4 SERVICE CONDITION
a Ambient Temp.
C LEVEL TRANSMITTER
1 Type
2 Type for Prob (MOC)
3 Extention pipe
Length:
MOC:
4 Measuring Cell linearity
5 DIAPHRAGM SEAL
6 Measuring Range
7 Accuracy
8 Automatic Temperature Compensation
9 Output signal
10 Voltage Protection
11 Housing MOC
-
7/30/2019 Instrumentation Data Sheets
27/28
12 Make
D DO ANALYSER
1 Minimum Measuring range DO Temperature
2 Accuracy DO Temperature
3 Reaction Time
4 Temperature Tolerance
5 Protection Class6 Resolution of Data
7 Probe Type
8 Zero point calibration required/not required
9 Make
Transmitter
10 Display Type
11 Air Compensation (yes/no)
12 Separate Output for Temperature (yes/no)
13 Output Type
14 Housing MOC
15 Voltage Protection
Immersion Armature and Support
16 Depth of immersion (yes/No)
17 Support Type
18 Float Type
E ULTRASONIC FLOW METER
GENERAL
Tag no.
Quantity
Meter Size
Accuracy2 DESIGN DATA
a Fluid
b Pressure (Nor./Max.) kg/cm2g
c Temprature (Nor./Max.) OC
d Flow Rate (Nor/Max) m3/hr
e Velocity m/sec
f Range m3/hr
g SP. Gravity
h Viscosity CP
i Min. Conductivity S/cm
3 MATERIAL
a Body
b Tube
c Electrode
d Liner
e Grounding Ring
4 FLOW TRANSMITTER
a Output Isolated
b Local Display Indicator
-
7/30/2019 Instrumentation Data Sheets
28/28
c Power Supply
d Cable Entry
e Location
f Cable (in case of Remote)
g Mounting
5 REMARK
a Area Classificationb Enclosure Protection
c Liner Heating System
d Ambient Temp.
e Relative Humidity