instruction sheet for backup alarms and specialty …
TRANSCRIPT
430205REV. A 397
Printed in U.S.A.
INSTRUCTiON SHEETFOR
BACKUP ALARMS AND SPECIALTY ALARMS
SAFETY MESSAGE TO INSTAllERSOF
BACKUP ALARMS
People's lives depend on your safe installation of our productsin conformance with our instructions. It is necessary to read,understand and follow all instructions shipped with the products.In addition, listed below are some other important safety instruc-tions and pr~~'lUti().!!-sYOtH,pouldfoHQw. _
Failure to follow all safety precautions and instructions mayresult in property damage, serious injury, or death to you or othersyou are seeking to protect.
Thproperly install a backup alarm: you must have agood understanding of truck and heavy equipmentelectrical procedures and systems, along withproficiency in the installation and use of safetywarning equipment.
When drilling into a vehicle structure, be sure thatboth sides of the surface are clear of anything thatcould be damaged.
Locate Backup Alarm so it will operate safely underall conditions. The location must provide protectionfrom impact and adverse weather conditions whileallowing unobstructed sound projection to the targethazllrrl ",,"0<>
• Ensure that the vehicle's supply voltage IS wIthinthe voltage rating specified on the Backup Alarm.
You should frequently inspect the Backup Alarmsystem to ensure that it is operating properly andthat it is securely attached to the vehicle.
File these instructions in a safe place and refer tothem when maintaining and/or reinstalling theproduct.
These Backup Alarms are lightweight, low current, piezo-electric, solid-state audible warning devices. The housing isenvironmentally sealed against moisture, dust, and corrosion.
The compact design only requires 6.7 square inches of surfacearea for mounting. All units are supplied with a heavy-gaugeplated steel universal mounting bracket.
Operating VoltageOperating CurrentPulse FrequencyFrequencyTemperature Range
12-48VDC ±200/00.10A@12VDC80 Beeps per minute ±202400 Hz ±400 Hz-400 F to 1650 F(-400 C to +740 C)
The units are protected against reverse polarity andvoltage spikes.
III. KIT CONTENTS LIST.
Qty. Description Part No.
1 Bracket, Mounting 4302502 Screw, Pan Hd., 6-32 x 1/4" 2003161 Bolt, Hex Hd., 1/4-20 x 3/4" 2003332 Lockwasher, Int. Thoth, #6 2080061 Label, Warning 200399
Since this alarm is designed to concentrate its audiblealarm in the target hazard area only, it should bemounted approximately 4 ft. above ground level with theunit's grill facing the target hazard area.
Select a mounting location at the rear of the vehicle that willprovide protection from impact and adverse weather conditionswhile allowing unobstructed sound projection to the target hazardarea.
A suggested location is on the rear of the vehicle, just insidethe last cross member or other sturdy part of the body structure.The supplied "L-type" mounting bracket provides mountingflexibility and allows installation in a variety of locations.
A. Electrical.
1. Terminate one end of a user-supplied red (or white)...l8...gauge wiI:e-w.ith_1umppli~dJt.6 ring ter.mina1. TerminaW~n.e. eJ).dof a user-supplied black 18 gauge wire with the other #6 ringterminal.
2. Using a #6-32 x 1/4" screw and #6 lockwasher,connect the red (or white) wire to the "+" terminal on the alarm.Using a #6-32 x 1/4" screw and #6 lockwasher, connect the blackwire to the "-" terminal on the alarm.
3. Route the other end of the red (or white) wire to thevehicle's backup light circuit, or to an independent actuatingswitch. DO NOT connect the red (or white) wire to the backup-light circuit, or to the independent actuating switch, at this time.
Improper grounding could result in death or seriousinjury to those who rely on this device for safety. Theground connection (-) MUST be attached to a solid metalbody or chassis part that will provide a dependableground path as long as the device is to be used.
4. Connect the other end of the black wire to a knowngood chassis ground.
1. Mounting Bracket (see figure 1).
a. Using the bracket as a template, scribe fourdrill position marks. on the mounting surface.
Before drilling holes in ANY part of a vehicle, be surethat both sides of the mounting surface are clear of partsthat could be damaged; such as brake lines, fuel lines,electrical wiring or other vital parts.
Figure 1.
b. Drill four mounting holes (size determined bythe user-supplied mounting bolts) at the drill position marks.
c. Attach the alarm to the mounting bracketusing the 1/4-20x 3/4" hex head bolt and tighten the bolt com-pletely into the alarm. Ensure that the wires are not pinchedbetween the bracket and the alarm.
d. Secure the bracket/alarm assembly to the;mounting,surface'with user~supplied'#--lQ·screws.
1/4-20 x 314" LG.BOLT, HEX HD.(l)
J
290A3047I
2. Surface Mounting (see figure 2).
a. Scribe a drill position mark at the desired
Before drilling holes in ANY part of a vehicle, be surethat both sides of the IllOuntingsurface are clear of partsthat could be damaged; such as brake lines, fuel lines,electrical wiring or other vital parts.
c. Attach the alarm to the mounting surface usingthe 1/4-20x 3/4" hex head bolt and tighten the bolt completely intothe alarm. Ensure that the wires are not pinched between themounting surface and the alarm.
C. Final Installation and Testing.
1. See figure 3. Connect the red (or white) wire to thevehicle's backup light circuit, or to an independent actuatingswitch.
2. Install the WARNINGlabel in a location clearlyvisible to the operator at all times.
SAFETY MESSAGE TO OPERATORSOF
BACKUP ALARMS
Should the alarm become inoperative, it couldjeopardize the safety or lives ofthose who depend onthe alarm signal for safety.
Testing the Backup Alarm should be listed on thedaily maintenance report. The units on operatingvehicles must be tested each day prior to thevehicles' operation. Results of this test must berecorded in the maintenance, file.
Notify your supervisor that people operating thisequipment'MUST check for proper operation at thebeginning of every shift.
~K