instruction manual models 7716 and 7720 benchtop … · this instruction manual provides operation...

52
INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop Consistometer Revision T – January 2014 P/N: 7716-7720-10 S/N: ____________ 2001 N. Indianwood Ave. Broken Arrow, OK 74012 Telephone: 918-250-7200 Fax: 918-459-0165 E-mail: [email protected] Website: http://www.chandlereng.com

Upload: others

Post on 17-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop Consistometer

Revision T – January 2014 P/N: 7716-7720-10

S/N: ____________

2001 N. Indianwood Ave. Broken Arrow, OK 74012 Telephone: 918-250-7200

Fax: 918-459-0165 E-mail: [email protected] Website: http://www.chandlereng.com

Page 2: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

Copyright © 2014, by Chandler Engineering Company L.L.C. All rights reserved. Reproduction or use of contents in any manner is prohibited without express permission from Chandler Engineering Company L.L.C. While every precaution has been taken in the preparation of this manual, the publisher assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.

This publication contains the following trademarks and/or registered trademarks: AMETEK, CHANDLER ENGINEERING. These trademarks or registered trademarks and stylized logos are all owned by AMETEK, Inc. All other company, product and service names and logos are trademarks or service marks of their respective owners.

Page 3: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

TABLE OF CONTENTS T-1

Table of Contents General Information ................................................................. P-1

Introduction ........................................................................................................................... P-1 Purpose and Use ............................................................................................................... P-1 Description ....................................................................................................................... P-1

Features and Benefits ............................................................................................................ P-1 Specifications ........................................................................................................................ P-1 Safety Requirements .............................................................................................................. P-2 Where to Find Help ............................................................................................................... P-2

Section 1 – Installation ............................................................. 1-1 Unpacking the Instrument ..................................................................................................... 1-1 Utilities Required .................................................................................................................. 1-1 Tools/Equipment Required .................................................................................................... 1-1 Setting Up the Instrument ...................................................................................................... 1-1

Connecting Air and Water ............................................................................................... 1-1 Connecting Power to the Consistometer .......................................................................... 1-2

Section 2 – Operating Instructions ........................................... 2-1 Description of Valves and Switches ...................................................................................... 2-1

Timer (1) .......................................................................................................................... 2-1 Timer Switch (2) .............................................................................................................. 2-2 Recorder Switch (3) ......................................................................................................... 2-2 Coolant Switch (4) ........................................................................................................... 2-2 Pump Switch (5) .............................................................................................................. 2-2 Heater Switch (6) ............................................................................................................. 2-2 Motor Switch (7) .............................................................................................................. 2-2 Master Power Switch and Circuit Breaker (8) ................................................................. 2-2 Alarm Reset Switch (9) .................................................................................................... 2-2 Recorder Controls (10) .................................................................................................... 2-2 Model 7050 Temperature Controller (11) ....................................................................... 2-3 Consistency Display (12) ................................................................................................. 2-3 Pressure Release Valve (13) ............................................................................................ 2-3 Air Control Valve (14) ..................................................................................................... 2-3 Air-To-Cylinder Valve .................................................................................................... 2-3 Auto-Shutdown Features ................................................................................................. 2-4

Preparing the Instrument for a Test ....................................................................................... 2-4 Configuring the Consistency Display .............................................................................. 2-4 Programming the Temperature Controller ....................................................................... 2-4 API Slurry Cup Preparation ............................................................................................. 2-5

Running a Test ....................................................................................................................... 2-6 After the Test is Complete ..................................................................................................... 2-7

Section 3 – Maintenance .......................................................... 3-1 Tools Required ...................................................................................................................... 3-1 Test Cell Plug Maintenance .................................................................................................. 3-1

Page 4: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

T-2 TABLE OF CONTENTS

Control Console Removal ..................................................................................................... 3-1 Magnetic Drive Removal ...................................................................................................... 3-1

Disassembly of the Outer Rotor ....................................................................................... 3-2 Disassembly of the Inner Rotor ....................................................................................... 3-3

Slurry Cup Drive Removal and Service ................................................................................ 3-3 Cylinder Clean-Out ............................................................................................................... 3-3 High Pressure Filter ............................................................................................................... 3-4 Low Pressure Filter (Strainer) ............................................................................................... 3-4 Safety Head and Rupture Disc .............................................................................................. 3-4 High Pressure Valves ............................................................................................................ 3-5 Air Pressure Regulator Adjustment ....................................................................................... 3-5 Oil Reservoir Drain/Fill Procedure ....................................................................................... 3-5 Slurry Cup Potentiometer Service ......................................................................................... 3-5

Resistor Replacement ...................................................................................................... 3-6 Torsion Spring Replacement ........................................................................................... 3-6 Potentiometer Bearing Service ........................................................................................ 3-6

Circuit Breaker And Fuses .................................................................................................... 3-7 Motor Removal and Service .................................................................................................. 3-7 Motor Control Circuit Adjustments ...................................................................................... 3-7 High Pressure Pump Service ................................................................................................. 3-8

Air Drive Section ............................................................................................................. 3-8 Hydraulic Section ............................................................................................................ 3-8

Calibration Procedures .......................................................................................................... 3-9 Consistency Display Calibration ..................................................................................... 3-9 Model 7050 Temperature Controller Calibration ............................................................ 3-9 Temperature Controller Thermocouple ........................................................................... 3-9 Timer ................................................................................................................................ 3-9 Potentiometer Mechanism Calibration ............................................................................ 3-9

Maintenance Schedule ......................................................................................................... 3-10

Section 4 – Troubleshooting Guide ......................................... 4-1

Section 5 - Replacement Parts ................................................. 5-1 Model Number 7716 / 7720 .................................................................................................. 5-1

Section 6 - Drawings and Schematics ...................................... 6-1

Additional Documentation: Addendum to 7716/7720 instruments equipped with 5270

Page 5: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

PREFACE P-1

General Information Introduction

This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers. Purpose and Use

The pressurized consistometer is used to determine the length of time a given cement slurry remains in a fluid state at a desired temperature and pressure. This data is then used to compare various cements. The tests performed are known as Thickening Time Tests.

Complete details of the procedure are contained in API Spec 10 titled Materials and Testing for Well Cements. Description

Cement slurry is placed in the consistometer, pressure and temperature are increased according to the API schedules, or the specific schedules desired by the user, and the consistency of the slurry is recorded as a function of time. An automatic shut-down feature cools the instrument, and shuts down the heater and motor upon completion of the test.

Features and Benefits • Programmable temperature controller • Uses same slurry cup assembly as other Chandler consistometers • Rugged design • Easy to operate • Recorder for both viscosity and temperature • Magnetic drive system to reduce maintenance • Adjustable alarm for viscosity levels • Slurry container rotation at 150 rpm

Specifications Maximum Operating Temperature: Model 7716: 350oF (177oC) Model 7720: 400oF (204oC) Maximum Operating Pressure: Model 7716: 16,000 psig (110 MPa) Model 7720: 20,000 psig (138 MPa) Weight: 220 lbs. (100 kg) Dimensions: 26 in (66 cm) x 14 in (36 cm) x 21.5 in (55 cm) Electrical: 100-130 VAC or 200-240 VAC

Page 6: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

P-2 PREFACE

Safety Requirements READ BEFORE ATTEMPTING OPERATION OF INSTRUMENT The Chandler Engineering Model 7716/7720 Benchtop Consistometer is designed for operator safety. Any instrument that is capable of high temperatures and high pressures should always be operated with CAUTION!! To ensure safety: • Locate the instrument in a low traffic area. • Post signs where the instrument is being operated to warn non-operating personnel. • Read and understand instructions before attempting instrument operation. • Observe caution notes! • Observe and follow the warning labels on the instrument. • Never exceed the instrument maximum temperature and pressure ratings. • Always disconnect main power to the instrument before attempting any repair. • Turn off the heater at completion of each test. • Locate appropriately rated fire extinguishers within close proximity. Before attempting to operate the instrument, the operator should read and understand this manual.

Where to Find Help In the event of problems, contact your local sales representative or Chandler Engineering: • Telephone: 918-250-7200 • Fax: 918-459-0165 • E-mail: [email protected] • Website: www.chandlereng.com Instrument training classes are also available.

Page 7: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 1 – INSTALLATION 1-1

Section 1 – Installation Before the instrument is operated, the technician should study this operating and maintenance manual to become thoroughly familiar with the Model 7716/7720 Benchtop Consistometer.

Unpacking the Instrument After the instrument is removed from the shipping container, the operating equipment and spare parts on the packing list must be checked to affirm that all have been received and none are damaged. Note: File an insurance claim with your freight carrier if damage has occurred

during shipment. Verify all parts shown on the enclosed packing list have been received. If items are missing, please notify Chandler Engineering immediately.

Utilities Required • Air pressure, 50-100 psig (350 to 700 kPa) • Water, 20-80 psig (140-550 kPa) • Electrical, 100-130 VAC or 200-240 VAC Caution: Wiring should comply with local electrical codes.

Tools/Equipment Required A standard maintenance or mechanics tool set is adequate for the installation, operation, and maintenance of this instrument.

Setting Up the Instrument The consistometer has been designed as a benchtop instrument. The bench used to support this instrument must be sturdy and able to support the weight of the instrument (220 lbs., 100 kg). Connecting Air and Water

The consistometer requires nominal 50 - 100 psig (350 - 700 kPa) air pressure and 20 - 80 psig (140 – 550 kPa) water pressure for proper operation. All of the fitting threads are 1/4 NPT. 1. Connect the air supply line to the inlet labeled AIR. 2. Connect the water supply line to the inlet labeled WATER IN. 3. Connect the water drain line to the outlet labeled WATER OUT.

Page 8: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

1-2 SECTION 1 – INSTALLATION

Connecting Power to the Consistometer

1. Connect the supplied twist-on power connector to the receptacle at the rear of the unit. 2. Connect the power plug to an appropriately rated power source and receptacle. For user

safety a power plug and mating receptacle are required. Note: This receptacle MUST be properly grounded.

Page 9: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 2 – OPERATING INSTRUCTIONS 2-1

Section 2 – Operating Instructions Description of Valves and Switches

Figure 1: Front Control Panel

Figure 2: Valve Controls

Timer (1)

The Timer is used to record the thickening time of the cement slurry. The timer circuit and alarm circuits are interconnected. When a preset consistency value is reached, an alarm sounds and the timer is stopped. The timer may be restarted when the consistency drops below 90% of the preset consistency value. To reset the timer, push the ALARM RESET switch. The timer may also be reset by pushing the small circular button on the timer face. The timer will display in minutes and seconds.

1 4 5 6 7

8

9

10 11

12

2 3

15

14

13

Page 10: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

2-2 SECTION 2 – OPERATING INSTRUCTIONS

Timer Switch (2)

The Timer Switch is used to start the timer. Recorder Switch (3)

The Recorder Switch is used to provide power to the recorder and to begin recording. If the Recorder Switch is ON but the recorder does not power-up, verify that the ON/OFF switch on the recorder is turned ON. If the Recorder Switch is turned ON and there is power to the recorder, but the recorder does not collect data, press the REC button on the recorder to begin recording. Coolant Switch (4)

The Coolant Switch is used to manually turn on the cooling water to the cylinder upon completion of a test. The cooling water to the magnetic drive is always ON and is not controlled by the coolant switch. If the automatic shutdown feature is ON, the cooling water to the cylinder will automatically be turned on when an alarm condition is present. Pump Switch (5)

The Pump Switch is used to apply pressure to the cylinder during a test. The Pump Switch is turned ON until the desired pressure is reached and then turned OFF again. Heater Switch (6)

The Heater Switch is used to provide power to the heaters and is used in conjunction with the temperature controller. However, no power is supplied to the heaters until the Heater Switch is placed in the ON position. Motor Switch (7)

The Motor Switch is used to turn the motor on after the slurry cup has been placed in the instrument. The motor rotates at a fixed speed of 150 rpm, so the Motor Switch simply turns it on or off. Master Power Switch and Circuit Breaker (8)

The Master Power Switch on the control panel of the unit controls the power to the control functions of the unit. The Master Power Switch is also a 3 Amp circuit breaker that can be reset by turning the OFF then ON again. Alarm Reset Switch (9)

The Alarm Reset Switch is used to clear the alarm when an alarm condition is no longer present. Recorder Controls (10)

The strip chart recorder is used to record slurry temperature and consistency. The chart speed is fixed at 60 millimeters per hour and is not influenced by power line frequency. Power to the strip chart recorder is controlled by a switch (3) on the instrument front panel.

Page 11: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 2 – OPERATING INSTRUCTIONS 2-3

Refer to the Yokogawa recorder manual for detailed instructions on the operation of this recorder. Model 7050 Temperature Controller (11)

The Model 7050 Temperature Controller controls the 2500-Watt heater inside the test cell. The sample temperature is measured using the centerline thermocouple. The controller may be programmed in a variety of ways to stimulate actual well conditions. For the heater to function the Heater Switch (6) must be turned ON and the temperature controller must be operating. If a heat-up cycle must be stopped, the heater can be turned OFF by turning the Heater Switch to the OFF position or pressing the run/hold button on the controller until the light goes off. The three modes of operation of the temperature controller are as follows: • Ramp and Soak Mode • Multi-Set point Mode • Manual Mode Please see the 7050 Temperature Controller Manual for further detailed instructions on the operation of the temperature controller. Consistency Display (12)

The Consistency Display shows the current consistency value of the slurry being tested. The consistency is displayed in Bearden Units (Bc). The consistency display is equipped with circuitry that is used to sound an alarm and stop the timer when a user specified consistency is achieved. If the automatic shutdown feature is enabled, the alarm will also stop the motor and heater and start the flow of cooling water to the cylinder. As the slurry cup rotates about the paddle as detailed in API Specification 10, the resulting torque induced on the paddle by the slurry is measured using a potentiometer mechanism and a torsion spring. The angular deflection of the spring determines the cement consistency. Pressure Release Valve (13)

The Pressure Release Valve is used to relieve pressure on the test cell. This valve vents the test cell back to the reservoir. It can be slowly cracked open during a test to relieve some pressure in the case of a pressure over-shoot condition, but this should be undertaken with extreme caution. Air Control Valve (14)

The Air Control Valve is a three-way valve used to FILL the test cell and prime the pump, or EXHAUST the air pressure on the cell in preparation for blowing down the test cell. The third position is the AIR OFF position. Air-To-Cylinder Valve

The Air-to-Cylinder Valve sends air pressure to the test cell to force the mineral oil back to the internal reservoir. This operation is known as “blowing down the test cell”.

Page 12: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

2-4 SECTION 2 – OPERATING INSTRUCTIONS

Auto-Shutdown Features

The Models 7716/7720 include circuitry that can automatically end a thickening time test when a user selectable consistency value is reached. The automatic shutdown feature may be enabled by moving the slide switch below the thermocouple connection, at the rear of the control console, to its left-most position. Enabling the shutdown feature causes the motor and heater to stop and the flow of cylinder cooling water to start when an alarm condition occurs. Additionally, the timer is stopped and the audible alarm is activated.

Preparing the Instrument for a Test Prior to running a test, the following steps must be performed. Configuring the Consistency Display

The instructions for setting the Bearden Unit Alarm Level are listed below. 1. Remove the lid from the instrument. Press down on the flat spring-loaded middle part of

the latch. The latch will fall forward. Press back on the top of latch and lift off lid. 2. Press the ON/OFF switch to the ON position on the main instrument panel. 3. Press the button on the left side of the consistency display’s front panel labeled HIGH

SET PT READ/RST. This will display the consistency alarm high set point. 3. While pressing the HIGH SET PT READ/RST button, adjust the small screw above the

HIGH SET PT READ/RST button labeled ADJ until the desired alarm set point is reached. Clockwise rotation of the screw increases the alarm value while counterclockwise rotation decreases the alarm value. The alarm value may be set anywhere between 0 and 150 Bc.

4. Release the HIGH SET PT READ/RST button when the desired alarm level has been reached. The consistency alarm is now set. Note that the LOW SET PT READ/RST button is not used with this instrument.

5. Once the alarm is triggered it may be reset, by toggling the automatic shutdown switch located on the rear of the control console.

Programming the Temperature Controller

Program the temperature controller to the desired set point. (Following is a brief procedure for programming the controller. For complete instructions, see the Model 7050/7051 Temperature Controller Manual.) 1. Turn the instrument ON and verify that the Thermocouple is plugged in on the backside

of the instrument. If the thermocouple is not attached to the instrument, the temperature controller will display S.Br (Signal Break).

2. Press (page) button until the ProG menu appears. Press (scroll) button until tGt is displayed.

3. Enter the target set point. This value may be less than the current temperature if a chiller is being used. Press (UP/DOWN) buttons to change the value. Wait for the value to flash one time.

4. Press (page) button until ProG menu appears. Press (scroll) button until dur (duration) appears. This is the time to reach the target set point. Press (UP/DOWN)

Page 13: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 2 – OPERATING INSTRUCTIONS 2-5

buttons to change the value. Wait for the value to flash one time. If a ramp rate is used, the controller will prompt for a rate value.

5. Press (page) button until the current process value is displayed. 6. Press the Auto/Man button to place the controller in the Auto mode. 7. Press the Run/Hold button to start the program. The OP1 light should begin flashing

indicating the control output to the heater. API Slurry Cup Preparation

For an accurate thickening time test to be performed, it is important for the slurry cup to be properly maintained and prepared. The following procedure should serve as a guideline for slurry cup preparations. While assembling the slurry cup, refer to drawing 07-0031 in the Drawings section of this manual. 1. Thoroughly clean all parts and verify that all parts are in good condition. 2. Lightly grease all interior surfaces of the slurry cup with white lithium grease or the

equivalent. 3. Install the diaphragm support ring, the diaphragm, and the diaphragm backup plate onto

the paddle assembly. The diaphragm should be oriented so that the larger brass piece is at the top.

4. Slide the shear pin assembly onto the paddle shaft. Place the potentiometer mechanism

on the paddle shaft until it seats. Using an Allen wrench, align the shear pin assembly into the bottom of the potentiometer mechanism and tighten the set screw to secure it in place. Remove the potentiometer mechanism from the paddle shaft.

Diaphragm Back-up Plate

Diaphragm Support Ring

Diaphragm

Page 14: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

2-6 SECTION 2 – OPERATING INSTRUCTIONS

5. Install the complete paddle assembly into the slurry cup. 6. Screw the diaphragm lock-down ring into the top of the slurry cup while checking to

make sure the paddle turns freely. 7. Invert the slurry cup into the slurry cup support. 8. Prepare a cement slurry in accordance with API Spec 10. Caution: According to API specs: The cement has to be under test (under pressure)

within 5 minutes of mixing. 9. Fill the cup with prepared cement slurry to the bottom of the threads. 10. Remove the plug (pivot) from the center of the bottom cap. 11. Replace the bottom cap without the plug. Slowly screw the cap into place and add

cement through the hole if required. 12. Grease the plug and replace. 13. Rinse the exterior surfaces of the slurry cup.

Running a Test 1. Remove the test cell plug, if it is not already removed from the previous test. 2. Attach the long bail through the holes on the top of the prepared slurry cup and insert it

into the test cell, rotating it until the bottom pins engage the cup drive table. Remove the bail.

3. After the slurry cup is loaded into the cell, the potentiometer mechanism (pot. mech.) is pushed onto the slurry cup paddle shaft and the test cell contact pins. Attach the short bail to the top of the potentiometer and lower the pot mech into the test cell. When properly engaged, the top of the paddle shaft will be flush with the top of the torque measurement potentiometer bearing. Remove the bail.

4. Check to be certain that the slurry cup and pot mech are properly engaged. Turn the Motor Switch to ON. No rubbing noise should be heard.

Shear Pin Assembly

Page 15: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 2 – OPERATING INSTRUCTIONS 2-7

5. Screw the test cell plug into the cylinder by hand. The last turn of the plug seats the O-Ring seal and will offer slight resistance.

Note: Do not over-tighten the test cell plug. Hand-tightening the plug is sufficient

for a complete seal. 6. Slide the thermocouple through the test cell plug into the slurry cup paddle shaft. Start

the threads of the sealing gland into the test cell plug, but do not tighten the thermocouple at this time. Verify that the thermocouple is plugged in at the rear of the instrument.

7. Next, fill the test cell with oil. To accomplish this, close the Pressure Release Valve, and turn the AIR/FILL Control Valve to the FILL position. When oil escapes from the top thermocouple high-pressure fitting, tighten the sealing gland with a 5/8” wrench.

8. Turn the Pump Switch to the ON position to apply the initial pressure to the test cell. When the pressure reaches the desired level, turn the Pump Switch to the OFF position. Adjust the pressure as required throughout the test by turning the Pump Switch ON to increase pressure or by slowly cracking open the Pressure Release Valve to relieve pressure. Use care to open the Pressure Release Valve slowly when attempting to bleed pressure.

9. To begin the test, press the buttons on the temperature controller to AUTO and RUN, turn the Heater Switch to the ON position, and start the timer. Once the desired set point has been reached the alarm will sound. Reset the alarm by pressing the Alarm Reset Button.

Note: Be certain to turn the heater switch on the front panel of the instrument to the

ON position. Turn the coolant control switch to ON if an external chiller is used.

Note: Once a program has been entered into the controller it may be reused by

pressing the Run/Hold button to run the program again.

After the Test is Complete 1. Stop the Temperature Controller by pressing HOLD on the RUN/HOLD button on the

controller, then turn the Heater Switch to the OFF position. 2. Press the Auto/Man button to place the controller in manual mode. 3. Use the Up/Down keys to change the output power percentage to 0.0%. 4. Turn the Timer switch on the front panel of the instrument to OFF. 5. Stop the motor by turning the Motor Switch to the OFF position. 6. Turn off the Pump switch. 7. Release the pressure. Verify that the Pump Switch is in the OFF position and OPEN the

Pressure Release Valve all the way. Warning: When the temperature of the sample is above 212°F, leave at least 500

psig on the sample during cool-down. 8. Start cooling the cylinder by placing the Coolant Switch to the ON position. 9. After the cell has cooled and all of the pressure has been relieved, the test cell must be

drained of oil. Turn the Air Control valve to the AIR/EXHAUST position and OPEN the

Page 16: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

2-8 SECTION 2 – OPERATING INSTRUCTIONS

Pressure Release valve. OPEN the Air-to-Cylinder valve. When air is heard exhausting from the vent, the cylinder is blown down.

10. Close the Air-to-Cylinder valve. Wait for the hissing to stop. 11. Close the Pressure Release valve and return the Air Control valve to the OFF position. 12. Turn off the Master switch. 13. Remove the sample thermocouple from the cell and remove the test cell plug. 14. Carefully lift the potentiometer mechanism and slurry cup out of the test cell using the

appropriate bails. The cup should be immersed immediately in a container of cold water, after which the slurry should be removed from the cup before hardening.

Page 17: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 3 – MAINTENANCE 3-1

Section 3 – Maintenance Warning: Remove power connections from the wall socket before opening the covers

or performing any service operations. The High Current 240 VAC or 120 VAC (120 VAC Option) within the unit is NOT switched by the MASTER POWER switch

Tools Required • Standard maintenance or mechanics tool set • Slurry Cup Drive Removal Tool (p/n 7750-0040) • Bearing Installation Tool (p/n 7750-0041)

Test Cell Plug Maintenance The Model 7716/7720 test cell plug uses an O-Ring with a metal back-up ring for sealing. Periodic replacement of the O-Ring will be necessary due to normal wear. The O-Ring will need to be replaced more frequently for high temperature / high pressure tests. The plug handles maybe unscrewed and replaced if necessary. 1. Remove the spiral retaining ring from the bottom of the plug. 2. Remove the O-Ring and check for wear. If the O-Ring is deformed, brittle, or has nicks

in it, it should be discarded. 3. Remove the metal back-up ring and clean the sealing surfaces. 4. Lightly grease the back-up ring with high temperature grease, then replace. 5. Replace the O-Ring. 6. Replace the spiral retaining ring.

Control Console Removal For any maintenance involving the magnetic drive, or for access to the oil reservoir, the control console must first be removed. 1. Remove the three screws holding the rear of the module to the top plate of the

consistometer. 2. Push the module forward and remove it from the top plate. Disconnect the cable between

the consistometer and the control module.

Magnetic Drive Removal The Model 7716 and 7720 Consistometer Magnetic drive contains rare earth magnets creating extremely strong magnetic forces.

Note: The rare earth magnets create strong magnetic forces. During removal of the

rotors take care not to pinch fingers, attract tools, etc. Remove any metallic debris from inside the rotor before replacing it onto the housing.

Page 18: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

3-2 SECTION 3 – MAINTENANCE

Magnetic Drive Assembly – NOTE: Previous versions of the 7716 and 7720 included a magnetic drive cooling jacket.

This jacket is no longer present.

1. Remove the motor drive belt. 2. Remove the magnetic drive-rotor retaining ring. 3. Carefully slide the magnetic drive rotor off of the housing. 4. Using a wrench, unscrew the magnetic drive housing from the cylinder. Disassembly of the Outer Rotor

Note: The magnet segments are bonded in-place inside the rotor. They are not removable except by the manufacturer.

1. Remove retaining clips from the ends of the rotor. 2. Remove the bearings from the rotor housing. Replace the bearings if necessary.

Rotor Retaining Ring

Water Connections

Mag Drive Cooling Jacket

Motor Drive Belt

Page 19: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 3 – MAINTENANCE 3-3

Disassembly of the Inner Rotor

Note: The magnet segments are bonded in place inside the rotor. They are not removable except by the manufacturer.

1. Remove the dog-point set screw from the spiral bevel gear. 2. Slide the spiral bevel gear and brass thrust ring off of the magnetic drive shaft. 3. Remove the knurled plug from the end of the magnetic drive housing. 4. Carefully remove the inner rotor assembly from the magnetic drive housing. 5. Remove the retaining clips from the ends of the inner rotor. 6. Remove the bearings from the ends of the rotor. Replace the bearings if necessary.

Slurry Cup Drive Removal and Service Refer to drawing 7750-0150 while performing the following steps. 1. Remove the magnetic drive assembly from the cylinder (see procedure above). 2. Remove the slurry cup centering pivot from the drive assembly. 3. Using Slurry Cup Drive Removal Tool, or a stiff wire with a hook on the end, reach into

the cylinder and hook the slurry cup drive assembly. The entire assembly will lift out of cylinder.

4. Loosen the two set screws in the table support housing and remove the drive table from the housing.

5. Remove the spiral retaining ring from the drive table. 6. Remove the bearing and bearing retaining ring. 7. Remove the drive shaft end support bearing from the table support housing if required

and press in a new bearing using the bearing installation tool. 8. To assemble, reverse the above steps. Tighten the housing set screws until slight

resistance is noticed while turning the cup table. These set screws do not need to be tight for the assembly to function properly.

9. Replace the slurry cup drive assembly into the cylinder. The U-shaped portion of the drive housing must be on the centerline of the magnetic drive shaft. Adjust the position of the housing by reaching through the magnetic drive mounting hole at the bottom of the cylinder wall.

10. Replace the magnetic drive assembly. The gear on the magnetic drive shaft will engage the gear on the slurry cup drive table as the drive shaft enters the shaft end support bearing.

Cylinder Clean-Out During normal usage of the consistometer, cement that may escape from the slurry cup due to the rapid pressure loss from the test cell will collect at the bottom of the cylinder below the Slurry Cup Drive assembly. Periodically, this cement should be cleaned-out. 1. Remove the magnetic drive following the procedure above. 2. Remove the slurry cup drive following the procedure above. 3. Remove the flush out plug at the bottom of the cylinder. 4. Flush the cylinder out thoroughly. 5. Replace the plug. 6. Replace the slurry cup drive.

Page 20: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

3-4 SECTION 3 – MAINTENANCE

7. Replace the magnetic drive.

High Pressure Filter The purpose of the high pressure filter is to protect the system from the abrasiveness of the cement that may escape from the slurry cup caused by a rapid release of pressure from the test cell. The filter is located at the left-front of the unit below the air regulator. A filter blocked or partially blocked with cement is evidenced by slow blowing-down of the cylinder. 1. Remove the front cover. 2. Remove the filter assembly from the unit. 3. Disassemble the filter and remove the filter element. 4. Clean the element in solvent or use an ultrasonic cleaner. If the filter element cannot be

cleaned, replace it (p/n P-1075). 5. Replace the reassembled filter assembly.

Low Pressure Filter (Strainer) The purpose of the low pressure filter is to protect the inlet check valve on the pump from any debris that may accumulate in the oil reservoir. The filter is a wire-mesh filter that may be cleaned in solvent. The low pressure filter is located below the pressure gauge at the front of the unit.

1. Remove the front cover. 2. Remove the filter assembly from the unit. 3. Disassemble the filter and remove the filter element. 4. Clean the element in solvent or use an ultrasonic cleaner. If the filter element cannot be

cleaned, replace it (p/n P-3557). 5. Replace the reassembled filter assembly.

Safety Head and Rupture Disc The safety head contains the rupture disc. The purpose of the rupture disc is to protect the system from over-pressurization. The rating of the rupture disc is above 20,000 psig. In the event of failure of the rupture disc, all system pressure is bled back to the oil reservoir. The safety head assembly is located above the pump at the front of the unit. 1. Remove the front cover. 2. Remove the safety head assembly from the unit. 3. Disassemble and inspect the rupture disc. Replace the disc if necessary. 4. Replace the reassembled safety head assembly.

Page 21: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 3 – MAINTENANCE 3-5

High Pressure Valves The consistometer uses two high pressure valves to control the test cell pressure. The valve seats in these valves can become worn due to abrasion or over-tightening of the valve stem. These valves are labeled PRESSURE RELEASE and AIR TO CYLINDER. 1. Remove the Control Console Assembly. See Control Console Removal. 2. Remove the valve handles, screws, and nuts supporting the valve bodies, the air control

valve, and top plate. 3. Remove the top plate from the unit. 4. Remove the high pressure valves. Replace the valve(s).

Air Pressure Regulator Adjustment The air pressure regulator is located at the left front of the consistometer, behind the front cover. The adjustment may be performed by hand. The adjustment is required if the pump will not pressurize the test cell to a desired pressure during a thickening time test. 1. Remove the front cover from the consistometer. 2. Turn the air pressure regulator knob clockwise to increase the discharge of air pressure.

Oil Reservoir Drain/Fill Procedure 1. Remove the front cover from the consistometer. 2. Attach a flexible hose from the oil reservoir drain valve to a convenient container used

for discarding the mineral oil. The reservoir holds approximately 2 quarts/liters of oil. 3. Open the oil reservoir drain valve. 4. Turn the AIR CONTROL valve to the AIR/FILL position and be ready to close the oil

reservoir drain valve when the reservoir is empty. 5. Remove the fill plug from the top of the oil reservoir. 6. Using a funnel, fill the reservoir with approximately 2 quarts/liters of clean mineral oil. 7. Replace the oil fill plug. 8. Replace the front cover.

Slurry Cup Potentiometer Service The slurry cup potentiometer (Pot. Mech.) is the resistive device that proportionally measures the torque on the API paddle during a thickening time test. The torque is measured with a wound resistor and a calibrated torsion spring. The torque is proportional to the deflection of the spring. The resistance is measured via the contact pins through the wall of the cylinder. Refer to drawing 07-0539 for assistance while completing the procedures below.

Page 22: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

3-6 SECTION 3 – MAINTENANCE

Resistor Replacement

1. Remove Shaft Bearing Retainer and Contact Arm. 2. Remove the old resistor using care to prevent damage to the slot. 3. Position the new resistor straight side down and with equal overlap beyond the contact

strips. 4. Seat the resistor firmly in the slot using a flat piece of wood. The top surface of the

resistor must be level. 5. Use a hardened rod (shank of drill bit) to rub the top surface of the resistor. This

burnishes the top of the resistor so that the contact arm will slide smoothly. 6. Rotate the contact arm by hand. Affirm that the arm makes contact with the resistor over

the full range of travel. If necessary, adjust the arm by bending it up or down. 7. Adjust the position of the Stop Arm, if necessary, to obtain full travel of the contact arm. 8. Replace the Shaft Bearing Retainer and check the potentiometer with the calibration

device. Torsion Spring Replacement

1. Remove Shaft Bearing Retainer and Contact Arm. 2. Remove the old Torsion Spring. 3. Install the new spring. Note that the spring winds tighter as the center shaft is turned

counterclockwise. 4. Replace the Contact Arm. 5. Loosen three screws on bottom of potentiometer. Do not remove. 6. Rotate Spring Adjuster until slack is taken out of spring and Contact Arm aligns with

first Contact Strip. Tighten screws. 7. Rotate the Contact Arm. Affirm that the spring does not bind or rub on the base below

the spring. 8. Replace the Shaft Bearing Retainer and check the potentiometer with the calibration

device. 9. To calibrate the potentiometer, see the Calibration Section of this manual. Potentiometer Bearing Service

1. Remove the Shaft Bearing Retainer and the Phillips Retaining Screw. 2. Remove the shaft bearing. 3. Loosen the set screws and slide the Stop Arm from the Spring Sleeve. 4. Remove the three set screws from the Frame. Remove the Spring Adjuster, the Spring

Adjuster Clamp, and the Spring Sleeve from the Frame. 5. Remove the two bearings and replace, if necessary. 6. Replace the Spring Sleeve and three set screws in the Spring Clamp. 7. Replace the Stop Arm and position it correctly before tightening the two set screws. 8. Replace the Shaft Bearing Retainer. 9. To calibrate the potentiometer see the Calibration Section of this manual.

Page 23: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 3 – MAINTENANCE 3-7

Circuit Breaker And Fuses The Consistometer is protected with a combination of a Circuit Breaker and Fuses. The inlet 240 VAC or 120 VAC (120 VAC Option) is fused with a 2 AMP cartridge fuse. The 240 VAC voltage is stepped-down with a transformer to 120 VAC to operate all the instrumentation, solenoid valves, etc. in the Consistometer. The 120 VAC instrument power is fused with the MAIN POWER SWITCH on the Console panel. This power switch is also a Circuit Breaker. Reset the circuit breaker by turning off the switch, then on. The cause for failure for the fuses/circuit breaker must be corrected before attempting to operate the Consistometer again. The DC Motor Control Circuit also has two fuses that protect the motor circuit from overloading. The Line fuse is a BUSS ABC 6 and the Armature fuse is a BUSS MDA .50. The cause for failure of these fuses must be corrected before attempting to operate the motor again. The fuses are located at the rear of the instrument near the power cord. The instrument should be unplugged from the electrical outlet before attempting to change the fuses.

Motor Removal and Service Note: The DC motor uses brushes that must be checked every 600 hours by the user.

The brushes should be replaced when their length is less than ¼” (7 mm). 1. Remove the motor bracket mounting screws. 2. Remove the magnetic drive belt. 3. Remove the motor. Note the polarity of the DC power connections. 4. Remove the brushes from the motor and inspect for wear. Replace the brushes if

necessary. 5. Lubricate the gear head on the motor with oil. SAE #50 - Non-detergent oil is

recommended for use in this gear head. 6. Remove the oil plug and fill until oil is observed at the hole. Check the oil level every 4-5

months or every 600 hours of operation.

Motor Control Circuit Adjustments The motor control circuit does not require any service operations for normal use. The following information is presented if the control circuit is replaced and requires adjustments. There are three adjustment potentiometers on the control circuit. These adjustment points are labeled MIN, MAX, and REG. The adjustments are performed with the belt removed from the motor pulley. A digital voltmeter and a digital tachometer are necessary for these adjustments.

Note: The following adjustments involve high DC voltages. Only qualified personnel

should attempt these adjustments. In most cases, the factory adjustments are adequate on a new control circuit.

Page 24: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

3-8 SECTION 3 – MAINTENANCE

Warning: When measuring the motor speed, use caution to avoid the exposed electrical terminals, belt drives, and other potentially dangerous components within the unit.

1. Turn the MIN pot. fully counterclockwise, and turn the external speed adjustment pot. to

the minimum speed position. The motor should be stopped. 2. Turn the external speed adjustment pot. fully clockwise. 3. Using a digital voltmeter, adjust MAX and REG pots until the following voltages are

measured. Adjust MAX until 3.7 VDC is measured across terminals S1 & S2. Adjust REG until 112 VDC is measured across terminals A1 & A2.

4. Using a digital tachometer, adjust the external speed adjustment pot., until motor speed is 150 RPM (API Spec. 10).

High Pressure Pump Service The High Pressure Pump used in the consistometer is an air-driven pump that uses mineral oil as a pressurizing medium. The pressure of the input air supply to the pump controls the outlet pressure of the pump. An air regulator and an electric solenoid valve on the air supply line control the input air supply pressure. As the air pressure to the pump is increased, the outlet fluid pressure from the pump increases. Service to the pump consists of the installation of seal kits available from Chandler Engineering.

1. Remove the pump from the system. 2. All parts removed from the pump should be cleaned in a suitable degreasing agent. 3. Inspect all moving parts for scratches or wear. Damaged parts must be replaced. 4. Replace all O-Rings when the pump is re-assembled. Air Drive Section

1. Disassemble the Air Drive section of the pump. Note: Care should be taken to prevent the spring behind the air piston from

escaping. 2. Remove all O-Rings from the assembly and replace with O-Rings from kit. 3. The air piston, air barrel, cycling valve and sleeve should be re-lubricated on assembly

with silicon grease. 4. Torque the tie rod nuts evenly to 50 inch-pounds. Hydraulic Section

1. Disassemble the Hydraulic section of the pump. 2. Remove all O-Rings from the assembly and replace with O-Rings from kit. 3. Use the following torque values during reassembly:

Inlet Check Valve: 125 ft.lbs. Outlet Check Valve: 50 ft.lbs.

Page 25: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 3 – MAINTENANCE 3-9

Calibration Procedures Consistency Display Calibration

No calibration is required. Model 7050 Temperature Controller Calibration

No calibration is normally required. Refer to the Model 7050 Manual for detailed instructions for operating the temperature controller. The calibration of the temperature controller may be checked using a thermocouple calibrator available from Chandler Engineering (p/n C09216). Temperature Controller Thermocouple

The thermocouple cannot actually be calibrated. However, the calibration can be checked. If the thermocouple calibration check shows that the thermocouple is reading out of tolerance, it should be replaced. See API Specification 10 for thermocouple calibration requirements. The calibration of the thermocouple can be checked using a thermocouple calibrator available from Chandler Engineering (p/n C09216). Timer

The calibration of the timer can be checked using a certified stopwatch. See API Specification 10 for timer calibration requirements. Potentiometer Mechanism Calibration

If the resistor or torsion spring on the potentiometer is changed, the potentiometer will need to be calibrated. Refer to drawing 07-0539 for assistance while completing the steps below. 1. Connect the potentiometer calibration device to the connector on the rear of the control

console. 2. Load the potentiometer with 400 grams. Tap on the calibrator until full deflection of the

spring is achieved. The display should read 100 Bc. 3. If the display does not read 100 Bc, adjust the value by turning the calibration screw

labeled as RECORDER SPAN on the rear of the control console. 4. When the display has been adjusted to read 100 Bc, remove the weights from the

calibrator. 5. The hook of the calibrator weighs 50 grams and should provide a reading on the display

of 9 Bc. 6. If the display does not read 9 Bc, the potentiometer mechanism requires adjustment. To

adjust, perform the following steps: a. Loosen the 3 recessed screws on the bottom of the potentiometer mechanism. b. On the top of the potentiometer mechanism, slightly move part 07-0065, the

spring adjuster (see drawing). c. Tighten the screws on the bottom of the potentiometer mechanism.

7. Replace the potentiometer in the calibrator and repeat steps 2-6 until both the 100 Bc and 9 Bc values are reading correctly.

Page 26: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

3-10 SECTION 3 – MAINTENANCE

Maintenance Schedule

MAINTENANCE SCHEDULE CONSISTOMETER

COMPONENT EACH TEST MONTHLY 3 MONTHS 6 MONTHS ANNUALSlurry Cup Disassemble, Clean,

Inspect

Potentiometer Mechanism

Clean, Lube, Inspect

Mag Drive Disassemble, Clean, Inspect

Oil Replace

Low Press. Filter Replace

σ High Pressure Filter

Disassemble, Clean, Inspect

Replace

Cylinder Flush and thoroughly clean

Cylinder Press. Release Valve

Replace

Pump Maint. By Qualified Factory Service Technician

Pressure Gauge Calibration

Drive Motor Set Speed

Temp. Controller Thermocouple

Inspect Calibration Calibrate By Qualified Factory Service Technician

Timer Calibration

Heater Test By Qualified Factory Service Technician

Reservoir Clean-Out By Qualified Factory Service Technician

Rupture Disk Replace

This maintenance schedule applies to normal usage conditions of two tests per day. Detailed procedures for these operations are contained in your manual. Per API Spec Requirements σ Where Applicable

Page 27: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 4 – TROUBLESHOOTING GUIDE 4-1

Section 4 – Troubleshooting Guide

Problem Solution No Power

1. Check the fuses, replace if necessary. 2. Check the main breaker, reset if necessary.

Control System Components Inoperative

1. Check the fuses, replace if necessary.

Erratic / Incorrect Temperature Read-out

1. Check for defective thermocouple, replace if

necessary. 2. Check for broken or corroded terminals. 3. Check all thermocouple wiring, replace if

necessary.

Drive Motor Inoperative

1. Check fuses, replace if necessary. 2. Check motor and controller for defects. 3. Check wiring. 4. Check for a defective switch.

Heater System Inoperative

1. Check for defective switch. 2. Check heater circuit to insure that there is not an

open connection. 3. Check that the heater is not shorted to ground. 4. Check the SSR for defects and verify the signal

from the SSR to the controller. 5. Verify that the controller is functioning properly,

replace if defective.

Unable to Build Pressure in the System

1. Verify that the pressure bleed valve is closed. 2. Check the pressure bleed valve for leaks, replace if

necessary.

Page 28: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

4-2 SECTION 4 – TROUBLESHOOTING GUIDE

Problem Solution 3. Check for leaks around the cylinder plug. Remove

the plug if a leak is found and clean, lube and replace the seal.

4. Check the rupture disc and verify that it has not

blown. Replace if necessary. 5. Check air to the pump and verify that air is present. 6. Check the oil level, add oil if necessary. 7. Pump may be malfunctioning, contact Chandler

Engineering service department for a pump rebuild. Plug is Jammed in the Cylinder

1. Verify that pressure has been released from the

system. Cool down the plug and unscrew by striking with rubber mallet.

2. Clean and lubricate threads thoroughly before each

test to avoid this condition. Also, do not over-tighten cylinder.

Pressure Will Not Bleed Off

1. Cement or other material has been lodged in the

manual valve. Disassemble and clean or replace valve.

Erratic Pumping Action

1. An air lock could be present in the pump piston

cavity. Increase the air drive pressure gradually to slow down pumping cycle.

2. Have pump serviced by Chandler Engineering

service department. Erratic Bearden Unit Readings on Recorder

1. If the reading drops to 0, check the following:

a. Pot mech resistor defective. b. Pot mech has disengaged from the drive bar

and/or is no longer touching the contact pins. c. Pot mech bearings are contaminated with

cement. d. Set screw on pot mech drive shaft is loose. e. Shear pin has broken.

2. If the reading jumps to 10, the contact pins may be shorted to the cylinder.

Pump Will Not Cycle, Pump Bypasses Air

1. Check air pressure and verify that it is sufficient

(50-100 psi).

Page 29: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 4 – TROUBLESHOOTING GUIDE 4-3

Problem Solution 2. The air system may be contaminated. 3. Remove the sleeve and cycling spool (under upper

cap of muffler). Clean, inspect, and lubricate with silicone grease.

False Cycle, Leak from Pilot Exhaust (top center of cap)

1. Install new air drive section seal kit.

Pump Cycles without Pumping or Does Not Stall

1. Check to be sure that all valves are seating properly. 2. Check for a leak in the consistometer hydraulic

system. Pump Fluid Appears at Muffler

1. High pressure seal leakage, replace if necessary. 2. Install new hydraulic section seal kit.

Page 30: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 31: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 5 – REPLACEMENT PARTS 5-1

Section 5 - Replacement Parts Model Number 7716 / 7720

Part Number Description 273066 Alarm, Audible 7-1112 Frame, Potentiometer 7-1113 Spring Set, Potentiometer Contact 7750-0010 Heater, 2500 W, 240 VAC 7750-0014 Retaining Ring, Cup Table 7750-0015 Housing, Cup Table Support 7750-0016 Plate, Slurry Cup Drive 7750-0019 Reservoir, Oil 7750-0024 Spacer, Valve 7750-0026 Pivot, Slurry Cup Centering 7750-0027 Bracket, Modified Motor 7750-0029 Nut, Heater Ferrule 7750-0030 Cover, Heater Lead 7750-0031 Label, Valve ID 7750-0040 Tool, Slurry Cup Drive Removal 7750-0041 Tool, Mag Drive Shaft Bearing Install. 7750-0112 Seal, Plug 7750-0115 Handle, Cylinder Plug 7750-0116 Plug, Cylinder Bottom 7750-0120 Ring, Cylinder Mounting 7750-0122 Plug, Cylinder Sealing 7750-0228 Plate, Top 7750-0231 Plate, Bottom 7750-0310 Enclosure, Electronics Module 7750-0413 Adapter, Bearing Front 7750-0414 Adapter, Bearing Rear 7750-0416 Bearing, Mag. Drive 7750-0417 Gear, Spiral Bevel 7750-0420 Housing Assembly, Mag. Drive Outer 7750-0422 Cap, Mag. Drive Housing 7750-0425 Bearing, Shaft Support 7750-0426 Plug, Mag. Drive Housing 7750-0428 Retainer, Mag. Drive Outer Housing 7750-0429 Bearing, Gear Drive Thrust 7750-0435 Shaft, Inner 7750-0436 Shaft Assembly, Mag. Drive Inner 7750-0510 Cylinder, Pressure 8-0240 Tube, Magnet C07478 Timer, LCD C07684 Recorder, Strip Chart C07882 Power Supply, 15VDC C08023 Display, Torque

Page 32: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

5-2 SECTION 5 – REPLACEMENT PARTS

Part Number Description C08590 Rupture Disk, 22,500 psi (7720) C08974 Pump, High Pressure C09011 Belt, Vee C09012 Pulley, Vee Belt C09022 Kit, Pump Spares (7720) C09928 Ribbon, Chart Recorder C10832 Paper, Recorder C11293 Gauge, Pressure P-0001 Bearing, Shaft P-0007 Bearing, Frame P-0061 O-Ring, Diaphragm P-0104 Gasket, Plug P-0317 Valve, Solenoid P-0860 Pin, Paddle P-1075 Filter, 1/4 Line P-1350 Pulley, Calibrator P-1351 Weight Set, Calibrator P-1352 Hanger, Calibrator Weight P-1353 Clip, Alligator P-1417 Plug, Calibrator P-1418 Socket, Calibrator P-1500 Valve, Oil Reservoir P-1680 Transformer, 240/120 VAC P-1765 Mineral Oil P-2192 Valve, 30000 Psig P-2264 Fuse, 3AG, 15A P-2265 Fuse Holder, 3AG P-2298 Valve, Ball 3-Way P-2380 Jack, Thermocouple Panel P-2570 Grease, Molykote P-2859 Filter, 1/4 P-2881 Switch, Rocker P-2943 Thermocouple P-3217 Grease, White Lithium P-3250 Retaining Ring P-3251 Retaining Ring P-3252 Retaining Ring P-3253 Bearing P-3254 Bearing, Cup Table P-3255 Motor, DC P-3256 Controller, DC Motor P-3265 O-Ring P-3266 O-Ring, Mag. Drive/Cylinder P-3330 Relay, Heater Control P-3357 Strainer, 100 Mesh

Page 33: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 5 – REPLACEMENT PARTS 5-3

Part Number Description P-3358 Screen, 100 Mesh P-3359 Receptacle, 250 VAC, 20A, Flanged P-3360 Plug, 250 VAC, 20A P-3362 Potentiometer, Motor Speed Adjustment P-3363 O-Ring P-3364 Bearing, Mag. Drive Shaft End P-3365 Set Screw, Mag. Drive Spiral Gear P-3390 Switch, Master Power P-3395 Retaining Ring P-3431 Relay, Auto-Shutdown P-3492 Switch, Slide P-3535 Kit, Pump Seal Overhaul (7716) P-3536 Kit, Pump Hyd. Sect. Overhaul (7716) P-3562 Brush Kit, Motor P-3613 Rupture Disc, 20,000 Psig (7716) P-3629 O-Ring

To ensure correct part replacement, always specify model and serial number of instrument when ordering or corresponding.

Page 34: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 35: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

SECTION 6 – DRAWINGS AND SCHEMATICS 6-1

Section 6 - Drawings and Schematics

Drawing Number Description 07-0031 Slurry Cup Assembly 07-0505-01 Assembly, Potentiometer Calibrator 07-0539 Potentiometer Mechanism 7750-0518 Cylinder Assembly 7750-0525 Reservoir Assembly 7750-0527 Wiring Diagram 7750-0528 Piping Diagram

Page 36: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

 

Page 37: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

BREAK SHARP EDGES, DEBURR

TITLE BLOCK REV: 2.0

NC 07-0031

CUP,SLURRY ASSY

D

C

B

AA

B

C

D

12345678

8 7 6

. ...

5 4 3 2 1

THIS DOCUMENT TO THE OWNER ON DEMAND.

E

F

E

F

SCALE:

SIZE

TITLE

SHEET:

REV.

NEXT ASSY

APPLICATION

USED ON

ENGR.:

CHECKED:

DRAWN:

APPROVALS DATE

UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN INCHES

2 PLACE

TOLERANCES:

3 PLACE

SURF. FINISH

0.030

ANGLES

0.0101 PLACE

0.005

AUTHORIZED BY THE OWNER IS FORBIDDEN. THE HOLDER AGREES TO RETURNREPRODUCTION OR DISSEMINATION IN ANY FORM EXCEPT AS EXPRESSLY

CHANDLER ENGINEERING

63

..

JBTCJJM

1/24/07

4/5/07

1/24/07 1 of 11:2

THIS DOCUMENT AND THE DRAWINGS AND TECHNICAL DATA CONTAINED HEREON ARE THE PROPERTY OF CHANDLER ENGINEERING COMPANY, LLC

1/2

DWG NO.

2

7

3. PACKAGE USING BOX C12549

NOTES:

(P-1454)

2. LUBRICATE ALL PARTS WITH WHITE LITHIUM GREASE.1. SHEAR PIN TO BE BENT UNDER DISC TO HOLD DISK AND BAR TOGETHER.

N

18

1610

14

2012

11

1

19

8

17

9

65

3

4

1

SLURRY CUP DIAPHRAGM 119 P-0860 PIN,ROLL,STL,.0625X.50 120 08-0087 COPPER GASKET 1

ITEM NO. PART NUMBER DESCRIPTION QTY.1 07-0043 CUP SHAFT 12 P-0844 PIN,SHEAR,BRS,0.035x0.50L 13 07-0046 DRIVE SHAFT BAR 14 07-0045 DRIVE SHAFT DISK 15 07-0036 CUP LOCK RING 16 07-0039 DIAPHRAGM SUPPORT 17 P-0061 ORING 28 07-0037 COLLAR 19 07-0537 HUB CAP 110 07-0042 PADDLE 111 07-0032 TAPERED SLURRY CUP 112 07-0033 SLURRY CUP BASE 114 07-0035 BASE PLUG PLUG 116 07-0538 HUB DIAPHRAGM 117 07-0536 PACKING RING 118 07-0038

REVISIONS

ZONE REV. DESCRIPTION DATE APPROVED

N ECN T1824; ADDED NOTE 3, CORRECTED ITEM NUMBERS 8/14/2008 TC

Page 38: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 39: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

26

26

SCREW,SKHSS,SS,8-32X0.250,CUP REF

WIRE,GROUNDING 1

25

P-202027REFSPRING,CONTACT07-110926REFSPRING,GROUND07-1110251COLLAR,SPRING,W/SCREWS07-0059241FRAME,MOUNTING,TEFLON,POT MECH07-111223

ITEM NO. PART NUMBER DESCRIPTION Default/QTY.1 07-0056 RETAINER,SHAFT BEARING 12 07-0058 ASSY,RESISTOR,POT MECH 13 07-0431 STOP,FRAME,POT MECH 14 07-0065 SPRING,ADJUSTER 15 07-0405 CLAMP,SPRING ADJUSTER 16 07-0216 INSULATOR 17 07-0064 SPRING,CALIBRATION 18 07-0055 SLEEVE SPRING 19 07-0060 ARM, CONTACT 1

10 07-0053 STOP,ARM 111 07-1113 SET, SPRING, CONTACT 112 P-2014 SCREW,PHMS,2-56X1/8 REF13 P-0001 BEARG,SGL ROW,.50X1.125X.25 114 P-0007 BEARING,INT,5MMX19MMX6MM 215 H-6045 SCREW,SHCS,BK,6-32X.625,ALN 316 P-2016 SCREW,PHSM,SS,4-40X0.500,PHIL 517 P-2017 SCREW,FHMS,SS,4-40X0.250,SLOT 118 P-2021 SCREW,SHCS,SS,10-32X0.500,AL 119 H-4119 SCREW,PHMS,SS,4-40X1.750,PHIL 420 H-4001 WASHER,LOCK,SS,#4 421 07-0638 STRIP,CONNECTING 222 07-1144

REVISIONS

ZONE REV. DESCRIPTION DATE APPROVED

Z ECN T1630, REMOVED P-2014 5/6/2008 JB/TC

AA ECN T1806; ADDED NOTE 5 8/14/2008 TC

AB ECN# T3972, REPLACE P-2019 W/H-6045 6/27/11 SS/TC

AC ECN# T4233, ADD NOTE 6 11/3/11 SS/TC

.

. .JJM 1/25/07

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

E

F

E

F

ITEM

ENGR.:

.

SCALE: 1:1 SHEET: 1 of 1

630.0050.0100.030

3 PLACE2 PLACE1 PLACE

ANGLESSURF. FINISH

TOLERANCES:DIMENSIONS IN INCHES

UNLESS OTHERWISE SPECIFIED

DATEAPPROVALS

DRAWN:

CHECKED:

USED ON

BREAK SHARP EDGES, DEBURR

NEXT ASSY

MATERIAL SPEC.DESCRIPTION-02 -01-04 -03

QTY. REQD.

PART NUMBER

PARTS LIST

CHANDLER ENGINEERING

1/2

1..

REV.DWG NO.

TITLE

SIZE

COPYRIGHT BY CHANDLER ENGINEERING COMPANY, LLC

TC 2/23/071/25/07JB

. .

APPLICATION

TITLE BLOCK REV: 2.0

D 07-0539 AC

.. .

THIS DOCUMENT AND THE DRAWINGS AND TECHNICAL DATA CONTAINED HEREON ARE THE PROPERTY OF CHANDLER ENGINEERING COMPANY, LLC REPRODUCTION OR DISSEMINATION IN ANY FORM EXCEPT AS EXPRESSLYAUTHORIZED BY THE OWNER IS FORBIDDEN. THE HOLDER AGREES TO RETURNTHIS DOCUMENT TO THE OWNER ON DEMAND.

POT,MECH,ASSY

3

2

ROTATION

27

4

WRAP ITEM 22AROUND SCREWAND TIGHTEN

1

ROTATION

A

SCALE 2 : 1DETAIL A

13

5

4

3

6

1

2

6

3

4

24

1

17

13

11

9

11

AA

8

2

23

19

18

16

10

14

20

7

5

622

LARGE DIAMETER HOLE OF ITEM 9 (07-0055) SLEEVE SPRING SHOULD BE ON TOP END TOWARDS ITEM 1 (07-0056). SMALL

PACKAGE USING C12546.

TOP OF ITEM 4 TO BE LEVEL WITH 07-1110. BEND EXCESS UNDER BOTTOM OF ASSEMBLY.

DIAMETER END SHOULD BE ON END WITH ITEM 2 (07-1112).

ONE OF THE P-2016 SCREWS NEEDS TO GO THRU THE 07-0638 CONNECTING STRIP, TO HOLD IT IN PLACE.

14

21

11

NOTES:

CONTACT ARM (ITEM 11) SHOULD ROTATE FROM FIRST WIRE WRAP AROUND TO LAST WIRE WRAP. ROTATION AS SHOWN.

ORIENT STOP ARM (ITEM 12) AS SHOWN, AGAINST (ITEM 21).

12

Page 40: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

REVISIONS

ZONE REV. DESCRIPTION DATE APPROVED

G ECN T1867; ADDED ITEMS 32 & 33 8/28/08 TC

JJM 8/28/08

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

E

F

E

F

ENGR.: SCALE: SHEET: 1 of 28/28/08

32

TC

CHANDLER ENGINEERING

1/20.0050.0100.030

3 PLACE2 PLACE1 PLACE

ANGLESSURF. FINISH

TOLERANCES:DIMENSIONS IN INCHES

UNLESS OTHERWISE SPECIFIED

DATEAPPROVALS

DRAWN:

CHECKED:

USED ON

BREAK SHARP EDGES, DEBURR

NEXT ASSY

REV.DWG NO.

TITLE

8/28/08TC

1:2

SIZE

COPYRIGHT BY CHANDLER ENGINEERING COMPANY, LLC

. .

APPLICATION

TITLE BLOCK REV: 2.0

D 7750-0518 G

THIS DOCUMENT AND THE DRAWINGS AND TECHNICAL DATA CONTAINED HEREON ARE THE PROPERTY OF CHANDLER ENGINEERING COMPANY, LLC REPRODUCTION OR DISSEMINATION IN ANY FORM EXCEPT AS EXPRESSLYAUTHORIZED BY THE OWNER IS FORBIDDEN. THE HOLDER AGREES TO RETURNTHIS DOCUMENT TO THE OWNER ON DEMAND.

CYLINDER ASSEMBLY

17

PRESSURE TEST PER 7750-0508 PROCEDURE.1.2. SEE DRAWING 7750-0438 TO ASSEMBLE MAG DRIVE.

12

3

4

25

5

3X

6

7

30

13

29

28

15

32

31

20

27

21

24

11

23

16

22

NOTES:

12

A A

Page 41: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

ITEM NO. PART NUMBER DESCRIPTION QTY.0 07-1590 PROC,BUNKER TEST W/5270 DACS REF0 7750-0508 PROC,MOD 7720 CYL ASSY REF0 7750-0534 PROC, BUNKER TEST F/7720 CONST REF0 7750-0535 PROC, BUNKER TEST F/7716 CONST REF1 77-0069 TC SPECIAL TYPE J 12 7222-0011 PLUG,CYLINDER,7222&7720 13 7750-0115 HANDLE, PLUG, CYLINDER 24 7750-0112 PLUG,SEAL RING 15 P-3265 ORING,BUNA,AS343-70 16 P-3250 RING,RETAINING 17 07-0539 POT,MECH,ASSY REF89

1011 R-0125 COPPER, TBG, .25 OD 5012 80-0021 THERMOCOUPLE, UCA 113 7750-0010 HEATER ASSY,220V,2500W 11415 7750-0510 CYLINDER, 7716/7720 116 7750-0438 MAGNETIC DRIVE ASSEMBLY 117 7750-0116 SEAL PLUG ASSEMBLY 1181920 P-3364 BEARG,BRZ,3/8IDX1/2ODX1/2LG 121 7750-0016 TABLE, SLURRY CUP 122 P-3395 RING, RETAINING, EXTERNAL 123 P-3254 BEARG,1.500ODX1.0625ID 124 7750-0014 RING, RETAINING, BEARING 125 7750-0015 HOUSING, SUPPORT, CUP TABLE 12627 7750-0026 PIVOT, CENTERING, SLURRY CUP 128 7750-0125 LOWER HEATER SPREADER 129 07-0031 CUP,SLURRY ASSY REF30 07-1523 COLLAR, HEATER 131 7750-0042 PIN,CONTACT,ASSEMBLY 332 C09400 CLAMP,BAND,21 3/16 L,3/4 W 233 C08333 SCREW,SKHSS,SS,6-32X0.250,DOG 2

20

SECTION A-A SCALE 1 : 1

1 23

4

5

6

11

32

13

16

17

7

28

25

15

22

24

27

12

B

30

31

29

23

C

8/28/08

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

E

F

E

F

ITEM

ENGR.: SCALE: SHEET: 2 of 2

32

JJM

CHANDLER ENGINEERING

8/28/08

1/20.0050.0100.030

3 PLACE2 PLACE1 PLACE

ANGLESSURF. FINISH

TOLERANCES:DIMENSIONS IN INCHES

UNLESS OTHERWISE SPECIFIED

DATEAPPROVALS

DRAWN:

CHECKED:

USED ON

BREAK SHARP EDGES, DEBURR

NEXT ASSY

MATERIAL SPEC.DESCRIPTION-02 -01-04 -03

QTY. REQD.

PART NUMBER

PARTS LIST

REV.DWG NO.

TITLE

SIZE

TC8/28/08TC

COPYRIGHT BY CHANDLER ENGINEERING COMPANY, LLC

. .

APPLICATION

TITLE BLOCK REV: 2.0

D 7750-0518 G

. . . . 1

1:2

THIS DOCUMENT AND THE DRAWINGS AND TECHNICAL DATA CONTAINED HEREON ARE THE PROPERTY OF CHANDLER ENGINEERING COMPANY, LLC REPRODUCTION OR DISSEMINATION IN ANY FORM EXCEPT AS EXPRESSLYAUTHORIZED BY THE OWNER IS FORBIDDEN. THE HOLDER AGREES TO RETURNTHIS DOCUMENT TO THE OWNER ON DEMAND.

CYLINDER ASSEMBLY

DETAIL B SCALE 1 : 1

4

SCALE 1 : 1DETAIL C

5

6

Page 42: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

7

6

43

9

10

2

8

1

5

.

5/9/08 TITLE BLOCK REV: 2.0

CSCALE:1:4

SIZE DWG. NO. REV.

APPLICATION

.

.TITLE

7750-0525

.

BREAK SHARP EDGES, DEBURR

. .

.

.

.

.

.

.

A

USED ONNEXT ASSY SURF. FINISH

CHANDLER ENGINEERING

1/263

COPYRIGHT BY CHANDLER ENGINEERING COMPANY LLC SHEET 1 OF 1

ANGLES

ON DEMAND. JJMTC

0.005

APPROVALSTC

DIMENSIONS IN INCHES [mm]

5/9/08DATE

5/9/08

1234

1234

A

B

CC

B

A

CHECKED:

DRAWN:

ENGR:

...

.

.

.

TOLERANCES: 1. PLACE 0.030 2. PLACE 0.010 3. PLACE

THIS DOCUMENT AND THE DRAWINGS AND TECHNICAL DATA CONTAINED HEREON ARETHE PROPERTY OF CHANDLER ENGINEERING COMPANY LLC. REPRODUCTION ORDISSEMINATION IN ANY FORM EXCEPT AS EXPRESSLY AUTHORIZED BY THE OWNER ISFORBIDDEN. THE HOLDER AGREES TO RETURN THE DOCUMENT TO THE OWNER

UNLESS OTHERWISE SPECIFIED

RESERVOIR ASSEMBLY

REVISIONS

TC

2X

ZONE REV. DESCRIPTION

2X

C ECN T2353; ADDED ITEM 11, NOTE 2 6/10/2009

NOTES:USE TEFLON TAPE ON ALL FITTINGS. 1.

REMOVE BRASS FERRULE, REPLACE WITH ITEM 11.C

C

2

DATE APPROVED

B ECN T1633; ADDED ADDITIONAL VIEWS 5/9/08 TC

2

C

ITEM NO. PART NUMBER DESCRIPTION QTY.1 36-0040 ADAPTER, GAUGE 12 7750-0019 RESERVOIR,OIL,ASSEMBLY 13 7750-0023 TUBE, DIP, RESERVOIR 14 C02156 PLUG, STL, 1/8MP, HEX, VT 15 C07435 TUBING, LEXAN, .375 OD X .250 ID .536 P-1255 ELBOW,BRS,1/4MPX1/4T,SW 27 P-1496 ELBOW,BRS,ST,1/4FPX1/4MP 18 P-1500 VALVE,NDL BRS UN 1/4MP X 1/4MP 19 P-3552 PLUG,SS,3/8MP,CA 1

10 P-3561 ELBOW,BRS,CPRSN,1/4MPX3/8T 211 C12911 FERRULE, 1/4", NYLON 2

Page 43: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

CHANDLER ENGINEERING

Page 44: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 45: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

AEROSPACE & DEFENSE

2001 North Indianwood Avenue, Broken Arrow, OK 74012 Phone: 918-250-7200 Fax: 918-459-0165

© 2008, by AMETEK, Inc. All rights reserved. e-mail: [email protected] www.chandlereng.com

Model 7716HPHT CONSISTOMETERA Critical Tool for Oil Well Drilling and Cementing

The Model 7716 Bench-Top Consistometer enables mobile and remote cement testing laboratories with very limited space to perform the fundamentally necessary testing of cement thickening time. This instrument is capable of testing cement thickening behavior in accordance with most API Spec 10A testing schedules.

Engineering Excellence for Long-term Performance

Chandler Engineering renowned manufacturing and field service experience is evident throughout the design of the Model 7716. This small, rugged instrument employs many of the design features of our full-sized consistometers in order to provide years of reliable service.

Operational Simplicity

The Model 7716 Bench-Top Consistometer is simple to operate with all of the operational controls conveniently located on the front panel alongside visible indications of thickening time, pressure and temperature. The slurry cup is designed so that closure, heating and pressurization can be achieved quickly.

The programmable temperature controller is equipped with proprietary Chandler Engineering firmware that accurately controls the rate of temperature rise of the slurry. Throughout the test, the built-in chart recorder tracks the temperature and cement consistency.

Once the user-set consistency is reached, an alarm will sound to alert the operator when the test is completed. The automatic shutdown feature of the instrument will turn off the motor, heater and timer as well as turn on the cooling water.

FEATURES3 Small, Transportable

Size for Field Locations, Mobile Labs and Offshore Platforms

3 Automatic Shutdown

3 Built-In Chart Recorder

3 Programmable Consistency Alarm

3 Magnetic Drive Coupling

3 Optional Pressure Controller

3 Optional Data Acquisition System

Page 46: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

Printed in the U.S.A. © 2008, by AMETEK, Inc. All rights reserved. XM808PDF (360000)

2001 North Indianwood Avenue, Broken Arrow, OK 74012 Tel: +1 918-250-7200 Fax: +1 918-459-0165e-mail: [email protected] www.chandlereng.com

Houston Sales and Services4903 W. Sam Houston Parkway, N., Suite A-400, Houston, TX 77041 Tel: +1 713-466-4900 Fax: +1 713-849-1924

Model 7716

SpecificationsMaximum Temperature

350ºF / 177ºC

Maximum Pressure

16,000 psi / 110 MPa

Slurry Cup Rotation Speed

150 rpm

Thickening Time Range

0 to 100 Bc (Bearden Units)

Consistency Resolution

1 Bc

Temperature Control

Programmable Controller

Pressure Control

Manual. Automatic pressure control is optional

Pressure Medium

White Mineral Oil

Data Acquisition

Two channel strip chart recorder (temp. & consistency) Chandler Engineering Model 5270 Data Acquisition and Control System for a stand-alone computer (optional)

Operating Temperature

32 to 120ºF / 0 to 50ºC

Compliance

API Spec 10A / ISO 10426-1

Utilities

Power Supply

220 VAC ±15% 50/60 Hz, 3kVA or 110 VAC ± 10% 50/60Hz, 3 kVA (optional)

Cooling Water

20-80 psi / 140 – 550 kPa

Compressed Air

50-100 psi / 345 – 690 kPa

Physical Dimensions

Dimensions (w x d x h):

26 in. x 14 in. x 21.5 in. / 66 x 36 x 55 cm

Weight:

220 lb / 100 kg

Shipping Information

Dimensions

39 in. x 19 in. x 29 in. / 91 x 54 x 74 cm

Weight

300 lb / 136 kg

Manufacturer’s specifications subject to change without notice

R0209.002

Operation can be further simplified by addition of the optional Model 5270 Data Acquisition and Control System which consists of interface electronics and custom software. To maximize system reliability, the software is purposefully designed to run on a stand-alone computer. The Model 5720 software can acquire test data as well as upload test protocols to multiple compatible Chandler Engineering instruments.

The usefulness of the Model 7716 Consistometer is not limited to the testing of cement thickening time. It can also be used to prepare slurries for other tests such as measuring free water content, testing for fluid loss or rheological properties and viscosity.

Page 47: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

AEROSPACE & DEFENSE

2001 North Indianwood Avenue, Broken Arrow, OK 74012 Phone: 918-250-7200 Fax: 918-459-0165

© 2008, by AMETEK, Inc. All rights reserved. e-mail: [email protected] www.chandlereng.com

FEATURES3 Small, Transportable

Size for Field Locations, Mobile Labs and Offshore Platforms

3 Automatic Shutdown

3 Built-In Chart Recorder

3 Programmable Consistency Alarm

3 Magnetic Drive Coupling

3 Optional Pressure Controller

3 Optional Data Acquisition System

Model 7720BENCH-TOP PRESSURIZED CONSISTOMETERA Critical Tool for Oil Well Cementing

The Model 7720 Bench-Top Consistometer enables mobile and remote cement testing laboratories with very limited space to perform the fundamentally necessary testing of cement thickening time. This instrument is capable of testing cement thickening behavior in accordance with most API Spec 10A testing schedules.

Engineering Excellence for Long-term Performance

Chandler Engineering’s renowned manufacturing and field service experience is evident throughout the design of the Model 7720. This small, rugged instrument employs many of the design features of our full-sized consistometers in order to provide years of reliable service.

A constant speed slurry cup drive rotates the cup at the required 150 rpm thereby improving testing accuracy and consistency. The drive’s reliability is maximized by use of a magnetic coupling system to connect the drive motor to the cup. The slurry cup is the same highly reliable design as is found in our other consistometers. The manual pressure control system is both simple to use and reliable. An automatic pressure control system is optional.

Operational Simplicity

The Model 7720 Bench-Top Consistometer is simple to operate with all of the operational controls conveniently located on the front panel alongside visible indications of thickening time, pressure and temperature. The slurry cup is designed so that closure, heating and pressurization can be achieved quickly.

The programmable temperature controller accurately controls the rate of

Page 48: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

Printed in the U.S.A. © 2008, by AMETEK, Inc. All rights reserved. XM808PDF (360000)

2001 North Indianwood Avenue, Broken Arrow, OK 74012 Tel: +1 918-250-7200 Fax: +1 918-459-0165e-mail: [email protected] www.chandlereng.com

Houston Sales and Services4903 W. Sam Houston Parkway, N., Suite A-400, Houston, TX 77041 Tel: +1 713-466-4900 Fax: +1 713-849-1924

Model 7720

SpecificationsMaximum Temperature

400ºF / 204ºC

Maximum Pressure

20,000 psi / 138 MPa

Slurry Cup Rotation Speed

150 rpm

Thickening Time Range

0 to 100 Bc (Bearden Units)

Consistency Resolution

1 Bc

Pressure Control

Manual. Automatic pressure control is optional

Pressure Medium

White Mineral Oil

Data Acquisition

Two channel strip chart recorder (temp. & consistency)

Chandler Engineering Model 5270 Data Acquisition and Control System for a stand-alone computer (optional)

Operating Temperature

32 to 120ºF / 0 to 50ºC

Compliance

API Spec 10A / ISO 10426-1

Utilities

Power Supply

220 VAC +/- 15% 50/60Hz, 3kVA or 110 VAC +/- 10% 50/60Hz, 3kVA (optional)

Cooling Water

20-80 psi / 140 – 550 kPa

Compressed Air

50-100 psi / 345 – 690 kPa

Physical Dimensions

Dimensions (W x D x H):

26 in. x 14 in. x 21.5 in. / 66 x 36 x 55 cm

Weight:

220 lb / 100 kg

Shipping Information

Dimensions

39 in. x 19 in. x 29 in. / 91 x 54 x 74 cm

Weight

300 lb / 136 kg

Manufacturer’s specifications subject to change without notice

R0209.002

temperature rise of the slurry. Throughout the test, the built-in chart recorder tracks the temperature and cement consistency.

Operation can be further simplified by addition of the optional Model 5270 Data Acquisition and Control System which consists of interface electronics and custom software.

The usefulness of the Model 7720 Consistometer is not limited to the testing of cement thickening time. It can also be used to condition slurries for other tests such as measuring free water content, testing for fluid loss or rheological properties and viscosity.

Page 49: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 50: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers

 

Page 51: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers
Page 52: INSTRUCTION MANUAL MODELS 7716 and 7720 Benchtop … · This instruction manual provides operation and maintenance instructions for the Models 7716 and 7720 Benchtop Consistometers