INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD
The National Institute for Nuclear Physics and High Energy Physics
Kruislaan 409 1098 SJ Amsterdam PO Box 418821009 DB AmsterdamThe Netherlands phone: +31 20 592 2000fax: +31 20 592 [email protected]
ELLIPTICAL HEAD
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 2
Before disconnecting the elliptical head,disconnect first one flange one the beam volume and then one flange on the detector volume.
VENTING USE: PURE NEON FOR THE BEAM VOLUME! AND NEON FOR THE DETECTOR VOLUME!
W A R N I N G AFTER VENTING FIRST OPEN VALVE SV421!
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 3
SWITCH OFF THE TURBO PUMPTP 301
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 4
DISCONNECT THE VENT VALVE CONNECTOR
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 5
TAKE OFF THE FRONT PART FROM THE PROTECTING COVER
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 6
CLOSE AIR PRESSURE VALVE ON VESSEL STAND
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 7
DISCONNECT 2 AIR PRESSURECONNECTIONSWITH WRENCH 14
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 8
DISCONNECT CONNECTORS VALVE SV421
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 9
DISCONNECT BELLOW
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 10
DISCONNECT ALL CABLES
220 V (3x) PT 100 (3x)
TP304
PI 301
PE301
AP411
DP411
OS 412 A & BOS 413 A & BOS 411 A & B
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 11
DISCONNECTWATER COOLING PLATE(L – key number 4)
DISCONNECTWATER COOLING
(Wrench 14)
DISCONNECTWATER COOLING
(Wrench 14)
DISCONNECTWATER COOLING PLATE(L – key number 4)
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 12Switch of water supply
Trolley under the valveDISCONNECT VALVE GV302
DISCONNECT CONNECTOR GV302
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 13
Disconnects 2 M6x12 hexagon socket head screw from the wake field suppressor at the spoke
in side of the vacuum vessel!
(Use L – key number 5)
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 14
DISCONNECTING THE ELLIPTICAL HEAD
M12 - WRENCH 18
LIFTING BRACKET
FLANGE SUPPORT
M12 - WRENCH 18
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 15
SLIDE THE ELLIPTCAL HEADINTO THE SLOTS AND COVER THE VACUUM SIDEWITH ALUMINUM FOIL
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 16
USED MATERIALS: Helicoflex ring
ALL HEXAGON HEAD SCREWS FOR UHV FLANGES:STAINLESS STEEL A4SPECIFICATION : LO-GE N° 507Partly threaded (b) Steel grade (ISO 3506) : A4 - 100 Traction resistance Rm : 1000N/mm2 Elastic limit Rp 0.2 : 940 N/mm2 Elongation at break A5 : 9%
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 17
ALARM NUMBERS
INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD 18
Delio DUARTE RAMOS from AT/VAChttp://consult.cern.ch/xwho/people/605500Tel:72465 (from outside: +41 22 76 72465 ) GSM: 165130 (from outside: +41 76 487 5130 ) Office: 112 1-010 Mailbox: M18800 E-mail: [email protected]: CERN
Adriana ROSSI from AT/VAChttp://consult.cern.ch/xwho/people/479442Tel:75978 (from outside: +41 22 76 75978 ) GSM: 163263 (from outside: +41 76 487 3263 ) Office: 30 1-010 Mailbox: M28810 E-mail: [email protected]: CERN
Luc JANSEN from PH/ULBhttp://consult.cern.ch/xwho/people/476681Tel:74024 (from outside: +41 22 76 74024) Office: 13 1-018 Mailbox: F26300 E-mail: [email protected] Experiment: LHCB Homeinstitute: NIKHEF
Martin DOETS from PH/ULBhttp://consult.cern.ch/xwho/people/513873Tel:77108 (from outside: +41 22 76 77108 ) Office: 22 1-006 Mailbox: E05300 E-mail: [email protected]: LHCB Homeinstitute: NIKHEF
Frans MUL from PH/ULBhttp://consult.cern.ch/xwho/people/583844Tel:76309 (from outside: +41 22 76 76309 ) Office: 13 1-026 Mailbox: F26200 E-mail: [email protected] Experiment: LHCB Homeinstitute: NIKHEF
Eddy JANS from PH/ULBhttp://consult.cern.ch/xwho/people/494203Tel:77108 (from outside: +41 22 76 77108 ) Office: 22 1-006 Mailbox: E05300 E-mail: [email protected]: LHCB Homeinstitute: NIKHEF