institute of atomic and molecular sciences, academia sinica, taiwan national taiwan university,...
TRANSCRIPT
Institute of Atomic and Molecular Sciences, Academia Sinica, TaiwanNational Taiwan University, TaiwanNational Central University, Taiwan
National Chung Cheng University, Taiwan
Chih-Hao Pai, Li-Chung Ha, Yen-Mu Chen, Hsu-Hsin Chu, Jiunn-Yuan Lin, Jyhpyng Wang, Szu-yuan Chen
Production of intense ultrashort mid-infrared pulses from a laser-wakefield electron accelerator
Methods for the generation of sub-ps mid-infrared pulses
Laser-wakefield electron accelerator operated in the bubble regime
Experimental setup and tomographic measurement
Generation of intense ultrashort mid-infrared pulses in the bubble regime
Outline
Generation of sub-ps MIR pulses
Free-electron lasers:
facility tunable spectral range
pulse duration energy/pulse
Jefferson Lab (USA)
1 - 14 m 0.2 - 2 ps 100 - 300 J
Frequency conversion in nonlinear crystals or gas media:
method wavelength range pulse duration energy/pulse
4-wave mixing
in air [1]
2.5 m - 5.5 m (bandwidth)
~13 fs ~1.5 J
DFG in AgGaS2 crystal [2]
6 m - 12 m (tunable range)
< 1 ps ~4.5 J
[1] Fuji et al., Opt. Lett. 32, 3330 (2007) [2] Imahoko et al., Appl. Phys. B 87, 629 (2007)
This work:
method wavelength range pulse duration energy/pulse
spectral broadening in the bubble regime
2 m - 12 m (bandwidth)
< 600 fs >3 mJ
Laser-wakefield electron accelerator operated in the bubble regime
Pukov et al., Appl. Phys. B 74, 355 (2002)
Laser-wakefield electron accelerator operated in the bubble regime
Pukov et al., Appl. Phys. B 74, 355 (2002)
energy: 50 MeV±10 % , divergene: 4 mradduration: ~10 fs (PIC simualtion)
Phys. Rev. E 75, 036402 (2007)
monoenergetic electron beam
200 mJ, 42 fs4x1019 cm-3 plasma density
Laser-wakefield electron accelerator operated in the bubble regime
spectral broadening
Faure et al., Phys. Rev. Lett. 95, 205003 (2005)
SLM: spatial light modulatorOAP: off-axis parabolic mirror
Diagnostic tools
(a) LANEX imaging system for electron beam
(b) Interferometry for plasma density measurement
Experimental setup for production of electron beam
SLM: spatial light modulatorOAP: off-axis parabolic mirror
Diagnostic tools
(a) LANEX imaging system for electron beam (replaced by (c))
(b) Interferometry for plasma density measurement
(c) MIR grating spectrometer
Diagnoses for MIR pulse (1): spectrometer
SLM: spatial light modulatorOAP: off-axis parabolic mirror
Diagnostic tools
(a) LANEX imaging system for electron beam (replaced by (d))
(b) Interferometry for plasma density measurement
(c) MIR grating spectrometer
(d) Pyroelectric detector
Diagnoses for MIR pulse (2): energy & beam profile
SLM: spatial light modulatorOAP: off-axis parabolic mirror
Diagnostic tools
(a) LANEX imaging system for electron beam (replaced by (e))
(b) Interferometry for plasma density measurement
(c) MIR grating spectrometer
(d) Pyroelectric detector
(e) Ge-wafer photo-switch
Diagnoses for MIR pulse (3): temporal profile
1. The machining beam ionizes and heats up selected regions.
2. Plasma heating leads to hydrodynamic expansion.
3. Several nanoseconds later the ionized region is evacuated.
4. Characteristics of final products as functions of pump-pulse
positions in the gas jet can be measured.
Scanning the interaction length for tomographic measurement
inte
nsi
ty o
f th
e
ma
chin
ing
pu
lse
Phys. Plasmas 12, 070707 (2005)Phys. Rev. Lett. 96, 095001 (2006)
Setup of the machining beam for tomographic measurement
focal spot: 20 m1.3 mm
function of the knife-edge: setting the interaction length
machining pulse
variable positionknife-edge or SLM
pump pulse
gas jetcylindrical lens pair
Self-injection of the monoenergetic electron beam and rapid growth of the MIR pulse occurs in the same region.
Dependence of MIR energy on interaction length
pump pulse energy: 205 mJpump pulse duration: 42 fsplasma density: 4.1x1019 cm-3
self-injection regions of electrons
The spectral profile of the MIR pulse suggests that the MIR pulse is produced by the strong spectral broadening of the pump pulse in the bubble regime.
Dependence of MIR spectra on interaction length
pump pulse energy: 205 mJpump pulse duration: 42 fsplasma density: 4.1x1019 cm-3
position (mm) spectra
1.51.6 a peak at 7.9 m and then broadened
> 1.85 a continuous distribution extending from the short wavelength side
0
Dependence of MIR spectra on interaction length
The spectral profile of the MIR pulse suggests that the MIR pulse is produced by the strong spectral broadening of the pump pulse in the bubble regime.
The Raman satellite is related to the modulational instability of the pump pulse in the early stage of the bubble regime evolution.
0
The MIR pulse energy increases with plasma density faster than the emergence of the monoenergetic electron beam. This is consistent with the bubble-regime model as the strong spectral broadening and self-compression is the cause of bubble formation.
Dependence of MIR energy on plasma density
pump pulse energy: 205 mJpump pulse duration: 42 fs
The MIR pulse has a lower pump energy threshold than that of the monoenergetic electron beam. This is consistent with the bubble-regime model as the strong spectral broadening and self-compression is the cause of bubble formation.
plasma density: 4.1x1019 cm-3
Dependence of MIR energy on pump energy
The MIR pulse is linearly polarized with the same polarization as the pump pulse. This is consistent with the bubble-regime model since the spectral broadening by phase modulation should preserve the pump laser polarization.
Polarization of the MIR pulse
polarization axis of the pump pulse
(1) coherent transition radiation from the electron bunch passing the plasma-vacuum boundary
(2) Cherenkov-type emission fr
om the electron bunch or the plasma wave
Both are radially polarized.
The data rule out the possibility of other mechanisms
Ref: Leemans et al., Phys. Rev. Lett. 91, 074802 (2003)
The MIR pulse is a flattop distribution with its diameter determined by the clear aperture of the ZnSe vacuum window.
The angular divergence of the MIR pulse is larger than the collection angle (8°) and the total MIR pulse energy should be considerably larger than 3 mJ.
MIR pulse energy vs. iris radius
pump pulse energy: 205 mJpump pulse duration: 42 fsplasma density: 4.1x1019 cm-3
radius of the ZnSe vacuum window
Ge-wafer photo-switch
MIR pulse
excitation pulse
pinhole
Ge-wafer photo-switch
MIR pulse
excitation pulse
pinhole
Ge-wafer photo-switch
MIR pulse
excitation pulse
pinhole
Temporal profile of the MIR pulse
Ge-wafer photo-switch
pump pulse: 205 mJ/42 fsexcitation pulse: 500 J/38 fsplasma density: 4.1x1019 cm-3
temporal profile
pulse duration
X ps4.6 ps 9.8 ps
5-mm Ge window
5-mm Ge window
X < 0.6 ps
Experimental data suggest that the MIR pulse is produced by the strong spectral broadening of the pump pulse in a laser- wakefield electron accelerator operated in the bubble regime.
Production of an intense MIR pulse with at least 3-mJ pulse energy and ultrashort pulse duration from a laser-wakefield electron accelerator is demonstrated. The output energy is one order of magnitude larger than that of the most intense free electron lasers, and three order of magnitude larger than that of conventional wave mixing.
Summary
Thanks for your attention.
Picture of experimental chamber
Picture of experimental chamber
machining beam main beam
(1) MIR(2) electron
beam