MK Elements Collection Electronic Dimmer Installation Guide Fitting and removing frontplate Locate top hooks on front plate to top edge of module. Lower front plate, locating hooks on sides and bottom edge. Carefully insert a 4mm screwdriver into the slots provided along the bottom edge of the frontplate. Carefully twist the screwdriver and lift the frontplate away disengaging the snap fits. Fitting the frontplate Removing the frontplate 2 2 1 1 Note: 1. A 2-Way switching installation may not work with a Mechanical 2-Way Switch, if incorporating an electric powered indicator (e.g. LED or neon) 2. Additional neutral wire is required on certain load types and 2-Way switching configurations. 3. The cable length between the two end point products must not exceed 40m, and the minimum cable size of 0.75mm². 4. When an Elements Electronic Dimmer is used as a 2-Way controlling device, both device must be of the same type. Do not mix different dimmer types i.e. leading edge and trailing edge. 5. Not applicable to K34499. Conventional 3-Wire 2-Way wiring 1 2 1 2 Common Common 2-way switches Dotted lines show alternative switch positions N L SW.L Lamp 2- Way installation with Elements 1 Gang Electronic Dimmer and 2-Way Mechanical Switch L N 1 R1 1 2 C Elements 1 Gang Electronic Dimmer Existing 3-wire 2-way wiring Refer to load type table for neutral requirement Load Live 2-Way Mechanical Switch L N 1 R1 1 2 C Elements 1 Gang Electronic Dimmer Refer to load type table for neutral requirement Load Live 2-Way Mechanical Switch Unused wire. Terminate both ends appropriately. 2-Way installation with any 2 Elements 1 Gang Electronic Products L N 1 R1 L N 1 R1 *Elements 1 Gang Electronic Dimmer/Switch Elements 1 Gang Electronic Dimmer Existing 3-wire 2-way wiring Neutral Load Live 2-Way installation with Elements 1 Gang Electronic Dimmer and 2-Way Mechanical Switch Conventional 2-Wire 2-Way wiring 1 2 1 2 Common Common 2-way switches Dotted lines show alternative switch positions N L Lamp 2-Way installation with any 2 Elements 2 Gang Electronic Products L N 1 R1 L N 1 2 2 R1 R2 R2 *Elements 2 Gang Electronic Dimmer/switch Elements 2 Gang Electronic Dimmer Existing 3-wire 2-way wiring 1. *Neutral is mandatory on the controlling electronic device. 2. If multi core cable is used, do not run R1 & R2 wires in the same multi core cable. 3. Refer to note 4 in this section for type of dimmer to be used. Important notes: Neutral Load 1 Load 2 Live 1 2 C L N 1 R1 Elements 1 Gang Electronic Dimmer Existing 2-wire 2-way wiring Refer to load type table for neutral requirement Load Live 2-Way Mechanical Switch 2-Way installation with any 2 Elements 1 Gang Electronic Products 2-Way installation with any 2 Elements 2 Gang Electronic Products L N 1 R1 L N 1 R1 Elements 1 Gang Electronic Dimmer Elements 1 Gang Electronic Dimmer/Switch Existing 2-wire 2-way wiring *Neutral Refer to load type table for neutral requirement Live Load L N 1 R1 L N 1 2 2 R1 R2 R2 Elements 2 Gang Electronic Dimmer Elements 2 Gang Electronic Dimmer/ Switch Existing 2-wire 2-way wiring *Neutral Live Load 2 Load 1 Important notes: 1. *Neutral is mandatory on the controlling electronic device. 2. If multi core cable is used, do not run R1 & R2 in the same multi core cable. 3. Refer to note 4 in this session for type of dimmer to be used. L N 1 R1 1 2 C Elements 1 Gang Electronic Dimmer/Switch Existing 2-wire 2-way wiring Refer to load type table for neutral requirement Load Live 2-Way mechanical Switch These wiring diagrams represent common 2-Way wiring options, for more visit www.mkelectric.com. For neutral connection to the Dimmer, refer to the specifications for load types that require a Neutral connection. If these loads are used without a Neutral connection, the dimmer and lamp may not operate correctly. For Mounting Boxes, the minimum depth required is 35mm. When using 2.5mm² cables the minimum box depth required is 40mm. Note: When carrying out insulation resistance testing, first disconnect the product. Failing to do this could damage the product and could also give spurious insulation readings. Note: Upon attaching new frontplate, the indication on the product may show erratic operation i.e. rapid flashing. This is normal as the product is adapting the new frontplate. This process may take up to 20 seconds. Note: In a single lamp installation it is recommended to connect neutral to the electronic dimmer. Installing the product Installation & safety instructions This product must be installed by a competent person (e.g. a qualified electrician) in accordance with these instructions and the appropriate current national wiring regulations. (e.g. the IEE Wiring Regulations BS 7671) While working on any appliance, turn off the mains supply to make sure that appliance is not live. Before changing a lamp or bulb ensure the electricity supply to the lamp holder or light fitting is off. Do not use electric screwdrivers or power tools to tighten the product. The mains supply to dimmer must be protected by a type ‘B’ or ‘C’ MCB with rating not higher than 10A. Before starting the appliance, make sure that all connections are as per the instructions, the cables are not stressed and the terminals are fully tightened. To prevent fire hazard, do not exceed the rated load specified for the appliance. Do not install the appliance in bathrooms, washrooms or any location subjected to splashes of water, condensation or dampness. How to install To ensure safe installation, you must read all the installation & safety instructions on page-1, and refer to the wiring diagrams on page-4. Installation 1. Ensure the depth of the back box is correct for the product and that it is fitted securely to the wall. 2. Install the cables in the normal way and, using the fixing screws supplied, mount the product, still minus its frontplate, to the wall. It is important the correct headed screws are used as any other may clash with the rear of the frontplate. 3. Do not over tighten the screws, so as to prevent damage or distortion to the product or support frame. Adjust so the frame or module sits squarely on the wall. 4. Fit the frontplate as shown on page-3. 1 2 Refer to these wiring diagrams for 1-Way and 2-Way switching installations. Elements Leading & Trailing Edge Dimmers can be controlled remotely by a 2-Way Mechanical Switch or an Elements Electronic Dimmer or Switch, if connected to its control port by the existing 2-Way wiring in the installation. Electronic Dimmer: 1-Way Switching Installation L N 1 R1 R2 2 Live Load 2 Neutral Load 1 Refer to load type table for neutral requirement Leading & Trailing Edge Dimmers Fluorescent Dimmer L N 1 + - Live Neutral connection is mandatory Neutral Lamp Analogue Dimmable Ballast L N + - Electronic Dimmer: 2-Way Switching Installation Wiring diagrams 4 5 6 7 8 Electronic Dimmer: 3-Wire 2-Way switching installation Electronic Dimmer: 2-Wire 2-Way switching installation 3 by Honeywell Unused wire. Terminate both ends appropriately.

Upload: others

Post on 08-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installing the product Wiring diagrams...on page-1, and refer to the wiring diagrams on page-4. Installation 1. Ensure the depth of the back box is correct for the product and that

MK Elements CollectionElectronic DimmerInstallation Guide

Fitting and removing frontplate

Locate top hooks on front plate to top edge of module.

Lower front plate, locating

hooks on sides and bottom

edge.

Carefully insert a 4mm screwdriver into the slots provided along the bottom edge of the frontplate.

Carefully twist the screwdriver and lift the frontplate away disengaging the snap �ts.

Fitting the frontplate Removing the frontplate

22

1 1

Note:1. A 2-Way switching installation may not work with a Mechanical 2-Way Switch, if incorporating an electric powered indicator (e.g. LED or neon)2. Additional neutral wire is required on certain load types and 2-Way switching con�gurations.3. The cable length between the two end point products must not exceed 40m, and the minimum cable size of 0.75mm².4. When an Elements Electronic Dimmer is used as a 2-Way controlling device, both device must be of the same type. Do not mix di�erent dimmer types i.e. leading edge and trailing edge.5. Not applicable to K34499.

Conventional 3-Wire 2-Way wiring

1 2 1 2

Common Common

2-way switches

Dotted lines show alternative switch positions

NL

SW.LLamp

2- Way installation with Elements 1 Gang Electronic Dimmer and 2-Way Mechanical Switch

L

N

1

R1

1

2

C

Elements 1 Gang Electronic Dimmer

Existing 3-wire 2-way wiring

Refer to load type table for neutral requirementLoad

Live

2-Way Mechanical Switch

L

N

1

R1

1

2

C

Elements 1 Gang Electronic Dimmer

Refer to load type table for neutral

requirement

Load

Live

2-Way Mechanical Switch

Unused wire. Terminate both ends appropriately.

2-Way installation with any 2 Elements 1 Gang Electronic Products

L

N

1

R1

L

N

1

R1

*Elements 1 Gang Electronic Dimmer/Switch

Elements 1 Gang Electronic Dimmer

Existing 3-wire 2-way wiring

Neutral

Load

Live 2-Way installation with Elements 1 Gang Electronic Dimmer and 2-Way Mechanical Switch

Conventional 2-Wire2-Way wiring

1 2 12

Common Common

2-way switches

Dotted lines show alternative switch positions

N

L

Lamp

2-Way installation with any 2 Elements 2 Gang Electronic Products

L

N

1

R1

L

N

1

22

R1

R2R2

*Elements 2 Gang Electronic Dimmer/switch

Elements 2 Gang Electronic Dimmer

Existing 3-wire 2-way wiring

1. *Neutral is mandatory on the controlling electronic device.2. If multi core cable is used, do not run R1 & R2 wires in the same multi core cable.3. Refer to note 4 in this section for type of dimmer to be used.

Important notes:

Neutral

Load 1Load 2

Live

1

2

C

L

N

1

R1

Elements 1 Gang Electronic Dimmer

Existing 2-wire 2-way wiring

Refer to loadtype tablefor neutral

requirement

Load

Live

2-Way Mechanical Switch

2-Way installation with any 2 Elements 1 Gang Electronic Products

2-Way installation with any 2 Elements 2 Gang Electronic Products

L

N

1

R1

L

N

1

R1

Elements 1 Gang Electronic Dimmer

Elements 1 Gang Electronic Dimmer/Switch

Existing 2-wire 2-way wiring

*NeutralRefer to load typetable for neutralrequirement

Live

Load

L

N

1

R1

L

N

1

22

R1

R2 R2

Elements 2 Gang Electronic Dimmer

Elements 2 Gang Electronic Dimmer/Switch

Existing 2-wire 2-way wiring

*Neutral

Live

Load 2Load 1

Important notes: 1. *Neutral is mandatory on the controlling electronic device.2. If multi core cable is used, do not run R1 & R2 in the same multi core cable.3. Refer to note 4 in this session for type of dimmer to be used.

L

N

1

R1

1

2

C

Elements 1 Gang Electronic Dimmer/Switch

Existing 2-wire 2-way wiring

Refer to load type table for neutral requirement

Load

Live

2-Way mechanical Switch

These wiring diagrams represent common 2-Way wiring options, for more visit www.mkelectric.com.

For neutral connection to the Dimmer, refer to the speci�cations for load types that require a Neutral connection. If these loads are used without a Neutral connection, the dimmer and lamp may not operate correctly.

For Mounting Boxes, the minimum depth required is 35mm. When using 2.5mm² cables the minimum box depth required is 40mm.

Note: When carrying out insulation resistance testing, �rst disconnect the product. Failing to do this could damage the product and could also give spurious insulation readings.

Note: Upon attaching new frontplate, the indication on the product may show erratic operation i.e. rapid �ashing. This is normal as the product is adapting the new frontplate. This process may take up to 20 seconds.

Note: In a single lamp installation it is recommended to connect neutral to the electronic dimmer.

Installing the product

Installation & safety instructions

This product must be installed by a competent person (e.g. a quali�ed electrician) in accordance with these instructions and the appropriate current national wiring regulations. (e.g. the IEE Wiring Regulations BS 7671)

While working on any appliance, turn o� the mains supply to make sure that appliance is not live. Before changing a lamp or bulb ensure the electricity supply to the lamp holder or light �tting is o�.

Do not use electric screwdrivers or power tools to tighten the product.

The mains supply to dimmer must be protected by a type ‘B’ or ‘C’ MCB with rating not higher than 10A.

Before starting the appliance, make sure that all connections are as per the instructions, the cables are not stressed and the terminals are fully tightened.

To prevent �re hazard, do not exceed the rated load speci�ed for the appliance.

Do not install the appliance in bathrooms, washrooms or any location subjected to splashes of water, condensation or dampness.

How to install

To ensure safe installation, you must read all the installation & safety instructions on page-1, and refer to the wiring diagrams on page-4.

Installation1. Ensure the depth of the back box is correct for the product and that it is �tted securely to the wall.

2. Install the cables in the normal way and, using the �xing screws supplied, mount the product, still minus its frontplate, to the wall. It is important the correct headed screws are used as any other may clash with the rear of the frontplate.

3. Do not over tighten the screws, so as to prevent damage or distortion to the product or support frame. Adjust so the frame or module sits squarely on the wall.

4. Fit the frontplate as shown on page-3.

1 2

Refer to these wiring diagrams for 1-Way and 2-Way switching installations.

Elements Leading & Trailing Edge Dimmers can be controlled remotely by a 2-Way Mechanical Switch or an Elements Electronic Dimmer or Switch, if connected to its control port by the existing 2-Way wiring in the installation.

Electronic Dimmer: 1-Way Switching Installation

L

N

1

R1

R2

2

Live

Load 2

Neutral

Load 1

Refer to load type table for neutral

requirement

Leading & Trailing Edge Dimmers

Fluorescent Dimmer

L

N

1

+

-

Live

Neutral connection

is mandatory

Neutral

Lamp

Analogue Dimmable Ballast

LN

+

-

Electronic Dimmer: 2-Way Switching Installation

Wiring diagrams

4 5 6 7 8

Electronic Dimmer: 3-Wire 2-Way switching installation

Electronic Dimmer: 2-Wire 2-Way switching installation

3

by Honeywell

Unused wire. Terminate both ends appropriately.

Page 2: Installing the product Wiring diagrams...on page-1, and refer to the wiring diagrams on page-4. Installation 1. Ensure the depth of the back box is correct for the product and that

Note: 1. Overload is indicated by the ring indicator �ashing once every 3 seconds.2. The Electronic Dimmer will resume normal operation once the overload is removed, by switching o� and on.

Soft start operation

When the Electronic Dimmer is switched on, light levels gradually reach the desired level over a period of 1 to 3 seconds, greatly extending life expectancy of lamps by avoiding initial power surge.

Overload protection

If the Electronic Dimmer is overloaded input to lamp(s) will be reduced (or switched o� if overload is severe) to protect the device and the installation.

Maintenance

Cleaning

Please clean the device with a dry and soft lint free cloth. Do not use water or any abrasive solvent based or aerosol cleaners as this may damage, discolor or a�ect the �nish and safety of the appliance.

Features Power failure recovery

In case of power failure, the dimmer will restore to its previous state upon power restoration.

Minimum brightness adjustment

The User can adjust the minimum brightness level to suit their environment and ensure optimum lamp performance. See User Guide for programming details.

9 10 11

Trailing Edge Dimmers K34103

GLS/ Tungsten �lament, Mains Tungsten Halogen 25 – 500W

ELV Tungsten Halogen with Dimmable Electronic Transformer 35 – 500VA

K34104 & K34105 (Per gang)

25 – 300W

35 – 300VA

Dimmable LED Driver *4-150W(Max 5 LED drivers only)

*4-120W(Max 5 LED drivers only)

Neutral connection is mandatory on 1-10V Dimmer. Suitable for use with dimmable �uorescent or LED lighting which is driven by separate 0/1-10V control gear.

Suitable for use with 0/1-10V analogue dimmable ballast operating in accordance with IEC60929 annex E.

Note: This product is only suitable for use with ballasts which are the source of the control voltage. It is not suitable for any other load type.

1-10V Dimmer K34499

Rated Load 6AX

Maximum number of ballasts 10

Standard compliances

The products in this range comply with IEC 60669-2-1 and the following EC:• Low Voltage Directive (73/23/EEC)• Electromagnetic Compatibility Directive (89/336/EEC)• Restricted of Hazardous Substances (2011/65/EC)

Warranty

• The Company undertakes to replace or repair, at its discretion, this product should it become defective within a period of 20 years after delivery (5 years for mains related electronic products), solely as a result of faulty materials and/or workmanship. Understandably, if the product has not been installed or maintained in accordance with the Company’s instructions, has not been used appropriately, or if any attempt has been made to rectify, dismantle or alter the product in any way, the warranty will be invalidated. This warranty states the company’s entire liability. It does not extend to cover consequential loss or damage or installation costs arising from the defective product. This warranty does not restrict or infringe the normal statutory rights of the consumer.

• MK Electric wishes to make it clear that it owns all original designs of the products which it manufactures (whether or not listed in this lea�et) and that it will take all necessary legal action in any part of the world against any party found to be manufacturing, distributing, selling or otherwise dealing with any article which infringes the company’s intellectual property rights in its products, or any other right of the company therein.

Disposal

Product and packaging should be disposed o� via standard refuse facilities at the end of its useful life. Where ever possible packaging and components should be recycled.

Technical Help

Tel: Fax: [email protected]

Technical Help

Tel: Fax: [email protected]

+44 (0)1268 563720+44 (0)1268 563064+44 (0)1268 563720+44 (0)1268 563064

Customer Service

Tel: +44 (0) 1268 563000Fax: +44 (0) 1268 563405Fax: +44 (0) 1268 563365 (International)

[email protected]

Customer Service

Tel: +44 (0) 1268 563000Fax: +44 (0) 1268 563405Fax: +44 (0) 1268 563365 (International)

[email protected]

MK ElectricThe Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA. UK

www.mkelectric.comAll marks in this document identi�ed with ® or ™ symbol adjacent to the mark are trademarks of MK Electric Ltd.©Honeywell International Inc.

50081614-001 Rev.A

MK ElectricThe Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA. UK

www.mkelectric.comAll marks in this document identi�ed with ® or ™ symbol adjacent to the mark are trademarks of MK Electric Ltd.©Honeywell International Inc.

50081614-001 Rev.A

Load rating & type

Leading Edge Dimmers K34100

GLS/ Tungsten �lament, Mains Tungsten Halogen 40 - 500W

Mains dimmable LED lamp for incandescent replacement

6 - 150WMax.12 lamps

ELV Tungsten Halogen with dimmable Ferro-magnetic transformer 35 - 400VA

K34101 & K34102 (Per gang)

40 – 300W

6 - 120WMax. 12 lamps

35 - 240VA

Product speci�cations

Nominal mains supply voltage 220 to 240V a.c.

Max. acceptable mains �uctuation 198 to 264V a.c.

Mains frequency 50/60Hz ± 3Hz

Ambient temperature range 0°C to 45°C

Other informationTroubleshooting

Unable to �t frontplates to modulePlease check if you are �tting the correct frontplate to the correct module. The frontplate must match the module exactly, e.g. 1 Gang Electronic Dimmer Frontplate will only �t a 1 Gang Electronic Dimmer Module. Please refer to the instructions for �tting and removing frontplates on page-3.

Connected Lamp does not turn ON or DIMFirstly check the lamps have not expired.

Check connections and wiring to the device to ensure it has been installed correctly.

Check the circuit, by inspecting other devices on the same circuit, to ensure there is power input to the device.

Ring indicator �ashes once every 3 secondsThis is indication of an overload. The Electronic Dimmer will resume normal operation once the overload is removed, by switching o� and on.If you are facing a problem not listed here, please contact the MK technical team. (Contact details are listed on the last page)

Notes:1. Do not use loads of di�erent types on the same circuit.2. Not suitable for use with any other load type.3. *Neutral connection is required. It is recommended to connect neutral whenever possible to extend the load handling capability of the dimmer.

12 13 14 15

(Not applicable to K34499)