installation & operational guide_ver.2.9
DESCRIPTION
hiTRANSCRIPT
![Page 1: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/1.jpg)
www.gsinstrument.com
December 22, 2012
GS Instruments Co., Ltd.
Confidential and proprietary to GS Instruments Co., Ltd.
Copying, reproduction or distribution this information is strictly prohibited without prior written authorization from GS Ins truments Co., Ltd..
Installation & Operational Guide
Version 2.9
![Page 2: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/2.jpg)
LOGO
www.gsinstrument.com 2
INTRO
Before Installation TMB, Please check basic points.
1) O/S: Window XP, Window 7
2) Pre-testing of Remote Access: Between Local/Remote GUI and TMB-9100
3) Turn off BTS first before starting your works
4) Turn on TMB first after finishing your works
5) Calculate and consider the output power of BTS and Input signal level of TMB-9100
6) TMB-9100 is very high powered RF so that Be careful when you set TMB parameters.
7) Remote GUI: Click “MAIN" button (Refresh) after getting SMS from TMB-9100
8) Local GUI: Check “Refresh” for renewal information.
9) After turn on TMB, please wait 5- 10minutes for warming
![Page 3: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/3.jpg)
LOGO
www.gsinstrument.com 3
TMB-9100 Configuration
![Page 4: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/4.jpg)
LOGO
www.gsinstrument.com 4
Step 1. TMB Installation (Before)
* Preparation
Note Book (1) USB to RS-232C Cable (1) Molex 2pin to AC/DC Adaptor 6V 2A(1)
Connect each cable to MCU of TMB
![Page 5: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/5.jpg)
LOGO
www.gsinstrument.com 5
Step 1. TMB Installation (Before)
* Open “ Local GUI”
![Page 6: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/6.jpg)
LOGO
www.gsinstrument.com 6
Step 1. TMB Installation (Before)
• Check F/W version: 2.9 • Check Initial parameter setting
![Page 7: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/7.jpg)
LOGO
www.gsinstrument.com 7
Step 1. TMB Installation (Before)
* Set “Server Min No” through Local GUI (Mandatory)
![Page 8: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/8.jpg)
LOGO
www.gsinstrument.com 8
1) Enter Site Name 2) TMB SIM Card Number 2) Enter Alarm Reporting upto 4 number
Step 1. TMB Installation (Before)
![Page 9: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/9.jpg)
LOGO
www.gsinstrument.com 9
Step 1. TMB Installation (Before)
* Insert SIM Card to MCU of TMB
Please remember the number of SIM
![Page 10: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/10.jpg)
LOGO
www.gsinstrument.com 10
Step 2. TMB Installation
* Install TMB at right position
![Page 11: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/11.jpg)
LOGO
www.gsinstrument.com 11
Step 3. DC Cable Installation
1) Install DC cable from BTS room to the location of TMB 2) DC Power Supply Recommendation: +48V 40A 3) TMB Site: +48 +/- 15%, Total Electric Power: 1,300W
![Page 12: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/12.jpg)
LOGO
www.gsinstrument.com 12
Step 3. DC Cable Installation
4) Connect DC jack with DC cable
B: -48Volt, A: Ground
Local electrical code should be followed in connecting DC power to the MCPA 9100 system. In order
to connect DC Cable, connect cable to DC INPUT port, and then connect the other end to DC Power
Source. The DC input power cable is illustrated in Figure 1.
The DC cable from the base station is connected to the DC INPUT port as shown in Figure 1. Use
two AWG08 cable to the DC INPUT through bottom interface panel. The DC cable should be
protected with a 40-amp minimum circuit breaker.
Figure 1 DC Input Jack
![Page 13: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/13.jpg)
LOGO
www.gsinstrument.com 13
Step 3. DC Cable Installation
Step1: Preparation
Step2: Preparation
Step3: Top view
Step4: Insert AG8 wires & Contraction Tube
![Page 14: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/14.jpg)
LOGO
www.gsinstrument.com 14
Step 3. DC Cable Installation
Step5: Strip the wire
Step6: Pre-soldering (Cable & Hole)
Step7: Soldering fully
Step8: Apply heat to the contraction tube
![Page 15: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/15.jpg)
LOGO
www.gsinstrument.com 15
Step 3. DC Cable Installation
Step9: Apply heat to contraction tube
Step10: Combine connectors
Step11: Apply heat to the tube
![Page 16: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/16.jpg)
LOGO
www.gsinstrument.com 16
Step 4. Power Off BTS
1) Turn off the power amplifier (A Sector) of BTS
![Page 17: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/17.jpg)
LOGO
www.gsinstrument.com 17
Step 5. Cable Connection
1) Connect Jumper cable for each path 2) Shielding for water-proof at cable connector
BTS ANTENNA
Feeder
Feeder
Feeder
Feeder
Jumper
![Page 18: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/18.jpg)
LOGO
www.gsinstrument.com 18
3) Connect Jumper cables to each port
Step 5. Cable Connection
![Page 19: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/19.jpg)
LOGO
www.gsinstrument.com 19
Step 6. TMB Setting – Remote Access
Remote GUI
Caution: Please reinstall modem box and SIM card if responding is not good
1) Please disconnect and take out the SIM card and then plug in again 2) Please change your com port in your pc
Please wait 5-10mins after turn on the TMB while optimizing
This version is optimized with Window XP and Window 7.
![Page 20: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/20.jpg)
LOGO
www.gsinstrument.com 20
1) Execute TMB-9100_Remote GUI
2) Connect Modem Box to USB Port of your PC
Step 6. TMB Setting – Remote Access
![Page 21: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/21.jpg)
LOGO
www.gsinstrument.com 21
3) Check & Set Com Port - Check “Device manager Pin your PC
4) Click “Main” button
6) Click “Modem Check” button
5) Set “Sever Min No”
Step 6. TMB Setting – Remote Access
![Page 22: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/22.jpg)
LOGO
www.gsinstrument.com 22
7) Click “ Status Req”, “Info Req”, and “Control”
Step 6. TMB Setting – Remote Access
![Page 23: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/23.jpg)
LOGO
www.gsinstrument.com 23
8) Click “Refresh” or “Main” button.
If Alarm LEDs are not updated after receiving SMS from TMB, please click “Main” button
[Before]
[After]
Step 6. TMB Setting – Remote Access
![Page 24: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/24.jpg)
LOGO
www.gsinstrument.com 24
9) “Status Request” information
Step 6. TMB Setting – Remote Access
![Page 25: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/25.jpg)
LOGO
www.gsinstrument.com 25
10) “Info Request” information
Step 6. TMB Setting – Remote Access
![Page 26: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/26.jpg)
LOGO
www.gsinstrument.com 26
11) Control button – Set parameters
Step 6. TMB Setting – Remote Access
![Page 27: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/27.jpg)
LOGO
www.gsinstrument.com 27
Step 7. Turn on TMB
![Page 28: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/28.jpg)
LOGO
www.gsinstrument.com 28
Step 8. Turn on BTS
![Page 29: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/29.jpg)
LOGO
www.gsinstrument.com 29
Step 9. Input Signal Level Checking
1) Check Input Signal Level Caution: Please Consider and Calculate the input signal level and loss.
![Page 30: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/30.jpg)
LOGO
www.gsinstrument.com 30
2) Alarm Checking
ALARM CHECK
Step 9. Input Signal Level Checking
![Page 31: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/31.jpg)
LOGO
www.gsinstrument.com 31
Step 10. TMB Gain Setting
1) Check Output Power of GUI (TMB Gain 0)
* Generally you can see the total output power for Signaling channel on the top of the tower.
![Page 32: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/32.jpg)
LOGO
www.gsinstrument.com 32
2) TX Output Power setting (Reference)
TX output power setup table – Below table is for reference in input power variation +/-1dB
BTS Max Output Power Output Power
(TMB Gain 0dB) TMB9100 Gain Setting GUI Gain Control MCPA9100Output Power
2CH 80W 49.3dBm 43 8 12 51dBm
4CH 87W 49.4dBm 42 9 11 51dBm
8CH 80W 49.3dBm 41 10 10 51dBm
Step 10. TMB Gain Setting
* Max Output power was calculated according to Power Sharing of BTS
![Page 33: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/33.jpg)
LOGO
www.gsinstrument.com 33
- LNA Gain Setting * According to a site, it can be changed. It is basic setting of TMB-9100
1) TMB Output Power – Input signal power = TMB TX Gain or Check the GUI 2) RX & DIV Gain
NO TX GAIN RX GAIN DIV GAIN Remark
1 1 – 10dB 12dB 12dB
2 11 – 20dB 14dB 14dB
Step 11. TMB Gain Setting
![Page 34: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/34.jpg)
LOGO
www.gsinstrument.com 34
- Check TX / RX / DIV Gain (LNA Gain can be higher than TX Gain) - Check output power of TMB - Check Alarm LED
Gain setting
Alarm Checking
ALC Mode OFF
Output Power Check
Step 11. TMB Gain Setting
![Page 35: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/35.jpg)
LOGO
www.gsinstrument.com 35
Step 11. TMB Setting – Others
1) Enter Site Name 2) TMB SIM Card Number 2) Enter Alarm Reporting upto 4 number
![Page 36: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/36.jpg)
LOGO
www.gsinstrument.com 36
Step 12. Check output Power
1) Check output power of TMB with spectrum analyzer 2) connection with coupling port of TMB
TX Coupling port (-40 dB +/- 1dB) using a spectrum analyzer. And Add jumper cable loss. To protect the spectrum analyzer, use TX coupling port -20 dB fixed attenuator.
![Page 37: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/37.jpg)
LOGO
www.gsinstrument.com 37
Step 12. Check output Power
• According to traffics, the output power will be fluctuated. • Please check total power of TMB
![Page 38: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/38.jpg)
LOGO
www.gsinstrument.com 38
Appendix 1: TMB Operation
1. Auto Attenuation Function - TMB has automatic function to protect its circuit while output power is higher than 52dBM in traffic increasing time - The reduction of TX Gain will be reduced and the step is 0.5dB 2. ALC Mode - In high traffic sector, please set ALC Mode On and ALC Level. - Max ALC level range is from 40 to 51dB. - It will automatically optimize the TX Gain with 0.5dB step. 3. Auto Recovery Algorithm - TMB will alive automatically if TMB has Overpower alarm after 3minutes. 4. TMB Power Detection time - 100ms - It will provide real time measurement but the accuracy will be less than Spectrum Analyzer. 5. SMS delay or missing - While MCU is working with other job, it cannot update or report alarms and control command. - Try again to set or check TMB unit. - After setting TMB, it takes time to report new information. Tray again to get new information. - Responding time for Control command: 5sec to set (general environment) - Responding time for Request command: 10-20sec (general environment)
![Page 39: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/39.jpg)
LOGO
www.gsinstrument.com 39
Appendix 2: Remote GUI & Modem Box
1. Local GUI and Remote GUI are optimized for O/S of Window 7 and XP. Other version of O/S cannot be suitable for GUIs and Remote Access. 2. Modem Box cannot be compatible for USB port of your PC. Please use other USB Port or your PC if there are several Pop-up menu for disconnection. 3. If the communication between GUI and Modem box are disconnected, Pop up-menu can be generated. Please click “ok” and check Modem 4. If you order several message in case that you cannot receive replies from TMB or other purpose, this modem can handle every requests from you and TMB so that this message will be come. Please restart “Remote GUI” for solving the matter or turn off /on the modem box. 5. In few case, SIM card error will be happened. You connect and check everything is OK but if the communication between GUI and TMB is not proper, Please check SIM Card connection or SIM Card Error. 6. In Rare cases, the received SMS from TMB cannot be erased in Modem Box so that it can make unstable Remote Access. Please check “SMS Clean” button
Checking Points
![Page 40: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/40.jpg)
LOGO
www.gsinstrument.com 40
* Input Coupler: 1) TX/RX Signal Detect 2) GSM Modem Coupling
* By Pass Relay: 1) Main path bypass (TX/RX signal )
* By Pass Relay1: 1) DIV path bypass (RX1 signal )
* Cavity Filter: 1) TX/RX IN/OUT, 2) DIV IN/OUT
* Cavity Filter 2 1) TX/RX IN/OUT
* A Module 1) TX Variable Attenuation
* MCPA: 1) Multi carrier power amplifier 150W
* Main LNA: RX Low Noise Amplifier
* DIV LNA: Diversity Low Noise Amplifier
* Arrestor: 1) TX/RX path
* I/O Board: to control and manage Power Supply & Control Signal, Alarm Signal, and Detected information from/to all Modules except of MCPA
* DC Power Supply DC to DC Converter that outputs DC27V, DC12V, and DC9V
Appendix 1: TMB-9100 Modules
![Page 41: Installation & Operational Guide_Ver.2.9](https://reader033.vdocuments.us/reader033/viewer/2022051316/55cf8ddc550346703b8c09f8/html5/thumbnails/41.jpg)
LOGO
www.gsinstrument.com 41
- THE END -