installation manual - · pdf fileconcerning the use and cleaning of the unit according to the...
TRANSCRIPT
EnglishInstallation manualR410A Split series
Franais
Espaol
Manuel dinstallationSrie split R410A
Manual de instalacinSerie Split R410A
INSTALLATION MANUALR410A Split Series
ModelsRXS30LVJURXS36LVJURKS30LVJURKS36LVJU
00_CV_3P300674-3.indd 1 10/21/2011 1:32:11 PM
1English
Safety PrecautionsReadtheseSafetyPrecautionscarefullytoensurecorrectinstallation.ThismanualclassifiestheprecautionsintoDANGER,WARNINGandCAUTION.Besuretofollowalltheprecautionsbelow:theyareallimportantforensuringsafety.
DANGER ...... Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING .... Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION ..... Failure to follow any of CAUTION may in some cases result in grave consequences.
Thefollowingsafetysymbolsareusedthroughoutthismanual:
Besuretoobservethisinstruction. Besuretoestablishagroundconnection. Neverattempt.
Aftercompletinginstallation,testtheunittocheckforinstallationerrors.GivetheuseradequateinstructionsconcerningtheuseandcleaningoftheunitaccordingtotheOperationManual.
DANGERRefrigerantgasisheavierthanairandreplacesoxygen.Amassiveleakcouldleadtooxygendepletion,especiallyinbasements,andanasphyxiationhazardcouldoccurleadingtoseriousinjuryordeath.
Iftherefrigerantgasleaksduringinstallation,ventilatetheareaimmediately.Refrigerantgasmayproduceatoxicgasifitcomesincontactwithfiresuchasfromafanheater,stoveorcookingdevice.Exposuretothisgascouldcausesevereinjuryordeath.
Aftercompletingtheinstallationwork,checkthattherefrigerantgasdoesnotleak.Refrigerantgasmayproduceatoxicgasifitcomesincontactwithfiresuchasfromafanheater,stoveorcookingdevice.Exposuretothisgascouldcausesevereinjuryordeath.
Donotgroundunitstowaterpipes,telephonewiresorlightningrodsbecauseincompletegroundingcouldcauseasevereshockhazardresultinginsevereinjuryordeath,andtogaspipesbecauseagasleakcouldresultinanexplosionwhichcouldleadtosevereinjuryordeath.
Safelydisposeofthepackingmaterials.Packingmaterials,suchasnailsandothermetalorwoodenparts,maycausestabsorotherinjuries.Tearapartandthrowawayplasticpackagingbagssothatchildrenwillnotplaywiththem.Childrenplayingwithplasticbagsfacethedangerofdeathbysuffocation.
Donotinstallunitinanareawhereflammablematerialsarepresentduetoriskofexplosionresultinginseriousinjuryordeath.
Donotgroundunitstotelephonewiresorlightningrodsbecauselightningstrikescouldcauseasevereshockhazardresultinginsevereinjuryordeath,andtogaspipesbecauseagasleakcouldresultinanexplosionwhichcouldleadtosevereinjuryordeath.
WARNINGInstallationshallbelefttotheauthorizeddealeroranothertrainedprofessional.Improperinstallationmaycausewaterleakage,electricalshock,fire,orequipmentdamage.
Installtheairconditioneraccordingtotheinstructionsgiveninthismanual.Incompleteinstallationmaycausewaterleakage,electricalshock,fireorequipmentdamage.
Besuretousethesuppliedorexactspecifiedinstallationparts.Useofotherpartsmaycausetheunittocometofall,waterleakage,electricalshock,fireorequipmentdamage.
Installtheairconditioneronasolidbasethatislevelandcansupporttheweightoftheunit.Aninadequatebaseorincompleteinstallationmaycauseinjuryorequipmentdamageintheeventtheunitfallsoffthebaseorcomesloose.
Electricalworkshallbecarriedoutinaccordancewiththeinstallationmanualandthenational,stateandlocalelectricalwiringcodes.Insufficientcapacityorincompleteelectricalworkmaycauseelectricalshock,fireorequipmentdamage.
Besuretouseadedicatedpowercircuit.Neveruseapowersupplysharedbyanotherappliance.Followallappropriateelectricalcodes.
Forwiring,useawireorcablelongenoughtocovertheentiredistancewithnosplicesifpossible.Donotuseanextensioncord.Donotputotherloadsonthepowersupply.Useanonlyaseparatededicatedpowercircuit.(Failuretodosomaycauseabnormalheat,electricshock,fireorequipmentdamage.)
Usethespecifiedtypesofwiresforelectricalconnectionsbetweentheindoorandoutdoorunits.Followallstateandlocalelectricalcodes.Firmlyclamptheinter-unitwiresotheirterminalsreceivenoexternalstresses.Incompleteconnectionsorclampingmaycauseterminaloverheating,fireorequipmentdamage.
01_EN_3P300674-3.indd 1 10/13/2011 2:23:50 PM
2 English
Safety Precautions WARNING
Afterconnectingallwiresbesuretoshapethecablessothattheydonotputunduestressontheelectricalcovers,panelsorterminals.Installcoversoverthewires.Incompletecoverinstallationmaycauseterminaloverheating,electricalshock,fireorequipmentdamage.
Wheninstallingorrelocatingthesystem,besuretokeeptherefrigerantcircuitfreefromallsubstancesotherthanthespecifiedrefrigerant(R410A),suchasair.(Anypresenceofairorotherforeignsubstanceintherefrigerantcircuitcausesanabnormalpressurerisewhichmayresultinrupture,resultingininjury.)
Duringpump-down,stopthecompressorbeforeremovingtherefrigerantpiping.Ifthecompressorisstillrunningandthestopvalveisopenduringpump-down,airwillbesuckedinwhentherefrigerantpipingisremoved,causingabnormallyhighpressurewhichcouldleadtoequipmentdamageorandpersonalinjury.
Duringinstallation,attachtherefrigerantpipingsecurelybeforerunningthecompressor.Iftherefrigerantpipesarenotattachedandthestopvalveisopenduringpump-down,airwillbesuckedinwhenthecompressorisrun,causingabnormallyhighpressurewhichcouldleadtoequipmentdamageandpersonalinjury.
Besuretoinstallagroundfaultcircuitinterrupterbreaker.Failuretoinstallagroundfaultcircuitinterrupterbreakermayresultinelectricallyshocks,orfirepersonalinjury.
CAUTIONDonotinstalltheairconditionerwheregasleakagewouldbeexposedtoopenflames.Ifthegasleaksandbuildsuparoundtheunit,itmaycatchfire.
Establishdrainpipingaccordingtotheinstructionsofthismanual.Inadequatepipingmaycausewaterdamage.
Tightentheflarenutaccordingtothespecifiedtorque.Atorquewrenchshouldbeused.Iftheflarenutistightenedtoomuch,theflarenutmaycrackovertimeandcauserefrigerantleakage.
Donottouchtheheatexchangerfins.Improperhandlingmayresultininjury.
Beverycarefulaboutproducttransportation.SomeproductsusePPbandsforpackaging.DonotuseanyPPbandsforameansoftransportation.Itisdangerous.
Makesuretoprovideforadequatemeasuresinordertopreventthattheoutdoorunitbeusedasashelterbysmallanimals.Smallanimalsmakingcontactwithelectricalpartscancausemalfunctions,smokeorfire.Pleaseinstructthecustomertokeeptheareaaroundtheunitclean.
Thetemperatureofrefrigerantcircuitwillbehigh,pleasekeeptheinter-unitwireawayfromcopperpipesthatarenotthermallyinsulated.
ElectricalworkmustbeperformedinaccordancewiththeNEC/CECbyauthorizedpersonnelonly.
AccessoriesAccessoriessuppliedwiththeoutdoorunit:
Installationmanual 1 Drainsocketassembly
(Onlyheatpumpmodels)
1 Tube 2
Bindingband 2
AB
C
D
01_EN_3P300674-3.indd 2 10/13/2011 2:23:51 PM
3English
Precautions for Selecting the Location1) Chooseaplacesolidenoughtobeartheweightandvibrationoftheunit,wheretheoperationsoundswillnotbeamplified.2) Choosealocationwherethehotairdischargedfromtheunitortheoperationsoundswillnotdisturbtheneighborsoftheuser.3) Avoidinstallingnearbedroomssothatoperationsoundswillnotbeaproblem.4) Theremustbesufficientspacesforcarryingtheunitintoandoutofthesite.5) Theremustbesufficientspaceforairpassageandnoobstructionsaroundtheairinletandtheairoutlet.6) Thesitemustbefreefromthepossibilityofflammablegasleakageinanearbyplace.7) Installunits,powercordsandinter-unitwireatleast10ft(3m)awayfromtelevisionandradiosets.Thisistopreventinterference
toimagesandsounds.(Noisesmaybeheardeveniftheyaremorethan10ft(3m)awaydependingonradiowaveconditions.)8) Incoastalareasorotherplaceswithsaltyatmosphereofsulfategas,corrosionmayshortenthelifeoftheairconditioner.9) Sincedrainflowsoutoftheoutdoorunit,donotplaceanythingundertheunitwhichmustbekeptawayfrommoisture.
NOTECannotbeinstalledhangingfromceilingorstacked.
CAUTIONWhenoperatingtheairconditionerinalowoutdoorambienttemperature,besuretofollowtheinstructionsdescribedbelow.Topreventexposuretowind,installtheoutdoorunitwithitssuctionsidefacingthewall.
Neverinstalltheoutdoorunitatasitewherethesuctionsidemaybeexposeddirectlytowind.
Topreventexposuretowind,itisrecommendedtoinstallabaffleplateontheairdischargesideoftheoutdoorunit.
Inheavysnowfallareas,selectaninstallationsitewherethesnowwillnotaffecttheunit.
Construct a large canopy.Construct a pedestal.
Install the unit high enough off the ground to prevent burying in snow.
Precautions on InstallationCheckthestrengthandleveloftheinstallationgroundsothattheunitwillnotcauseanyoperatingvibrationornoiseafterinstalled.Inaccordancewiththefoundationdrawing,fixtheunitsecurelybymeansofthefoundationbolts.(Prepare4setsof1/2inch(M12)foundationbolts,nutsandwasherseachwhichareavailableonthemarket.)
Itisbesttoscrewinthefoundationboltsuntiltheirendsare3/4inch(20mm)fromthefoundationsurface.
3/4
inch
(2
0mm
)
01_EN_3P300674-3.indd 3 10/13/2011 2:23:51 PM
4 English
Outdoor Unit Installation Drawings
Max. allowable piping height
Min. allowable piping length
Max. allowable piping length 98.4ft (30m)
6.56ft (2m)
65.6ft (20m)
Liquid pipe
Gas pipe
O.D. 3/8 inch (9.5mm)
O.D. 5/8 inch (15.9mm)
0.54oz/ft (50g/m)
Additional refrigerant required for refrigerant pipe exceeding 32.8ft (10m) in length.
**
*
* Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance.
** The suggested shortest pipe length is 6.56ft (2m), in order to avoid noise from the outdoor unit and vibration. (Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
Wrap the insu