installation manual preliminary installation frosti -plus
TRANSCRIPT
i
Installation Manual preliminary installation FROSTI®-PLUS | Fig. 574 11
2 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
ENUse The KEMPER FROSTI®-PLUS is used as a frost-proof outdoor tap. Do not use the product for other purposes than described above. Any other uses constitute misuse.
WarningsBe sure to read and follow the warn-ings in the manual. Failing to do so can lead to personal injury or material damage!
Important warnings:Warning! Highlights risks that may result in injury, material damage or contami-nation of drinking water.Note! Highlights risks that may result in damage to the plant or dysfunction.
Warning! The FROSTI must be installed in accordance to Water Regulations, schedule 2, paragraph 15. The level of protection must be appropriate to the fluid category.
Precautions for preliminary installation
Drinking water installationIn order to prevent stagnation and bacterial contamination in the supply, it is recommended to loop the tap in the drinking water system.
* For technical and hygienic reasons, it is necessary to install the last min. 100 mm and max. 10 x DN as a functional individual supply line.
** The tap must be installed at least 250 mm above the maximum fluid level.
InstallationRead the manual and follow the instructions before installation! Installation and maintenance must be carried out by qualified plumbers.
Keep the manual for future reference!
The place of installation may not be at risk of flooding.
Perform a leak test after installation and before commissioning!
Priority must be given to the national standards and provisions on sanitary installations and accident prevention.
All dimension specifications are given in mm.
Warranty No warranty in case of:- Non-compliance with the manual.- Damage due to incorrect installation.- Unauthorised modification of the product.
BS EN 1717
max.
min
. 250
**min
. 100
**
DN
3 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
!
EN Installation and Operating Manual Frost-proof outdoor tap
FROSTI® | Fig. 577 11
3x
3x
BS EN 1717BS EN 806
Fig. 574 11
150 - 415
+
+
14
11
12
13
i
Item Designation
11 valve plug
12 spindle
13 valve plug and spindle
14 mounting plate
Art.-No.
B81095740101500
L51055740000100
B810957411015KP
C21005740000100
4 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
max. 2 %
min
. 3
5
max. 2 %
min
. 3
5
max. 2 %
min
. 3
5
max. 2 %
min
. 3
5
a
b
i
1 2
5 / 10 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
6 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
3x3x
43
1.
2.1.
2.
7 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
3x ! >0 ̊ C<0 ̊ C
pag. 2
10
0
DN
65
1.
2.
1.
2.
8 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
++
Fig. 574 00 005
+
Fig. 574 00 006
+
9 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
+
+
Fig. 574 00 002
10 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
11 / 12 – K410057400011-00 / 04.2018 – © www.kemper-olpe.de
Kemper UK & Ireland Ltd.2 Ripple Court Brockeridge business parkTwyningTewkesburyGlos, GL20 6FG
Phone +44 16 84 - 85 49 30Fax +44 16 84 - 85 49 [email protected] iiK
410057400011-00 / 04.2018