installation · pdf fileinstallation manual installation manual ... heart disease, high or...
TRANSCRIPT
INSTALLATION MANUAL
INSTALLATION MANUAL
ARIEL WS-902A Steam Shower
Page 2
INSTALLATION MANUAL
Table of Contents
Specs & Packing List 3Included Parts 4-5Installation Diagram 6Installation Guidelines & Warnings 7-9Cleaning the Steam Generator 10-11Step-by-Step Installation 12-14Control Panel Operation 15-16Connection Diagram 17Electrical Diagram 18
Page 3
INSTALLATION MANUAL
• Voltage AC110V
• Frequency 60Hz
• Water Voltage 0.1~0.2 Mpa
• Power of Steam Generator 2.65KW
Electrical Specifications
WS-902ASpec & Packing List
Hardware Required
Box 1
2x Piece of Back Board
2x Pieces of Fixed Glass Door
2x Pieces of Sliding Glass door
4x Water Resist Strips
2x Pieces of Magnet Strips for Aluminum Columns
2x Pieces of Aluminum Column with U-shpaed Plastic Steal
Box 2
2x Tray
2x Roof
2x Ordinary Shower Holding Bar
4x Steam pipe with one black plastic pad
2x Up and down bended aluminum column
2x U-shaped plastic seal
Also Included: Hardware Kit
Page 4
INSTALLATION MANUAL
1. Control Panel2. Soap Rail3. Foot Massager4. Steam Out Port5. Decorative LED Lights6. Hand Held Shower Wand7. Temperature Sensor8. On/Off Valve9. Function Selector Valve10. Acupuncture Body Jets
35. Shampoo Rail36. Soap Box
WS-902AIncluded Parts
1
2
3
4
5
ADJUSTABLE SHOWER WAND RAIL
SHAMPOO RAIL
36
6
8
9
7
10
DOORS
34
33
32
32. Door Roller Hole33. Glass Door34. Fixed Glass
35
Page 5
INSTALLATION MANUAL
TOP
BOTTOM
11. Ceiling12. Screw Hole13. Exhaust Fan14. “UP” Top Railing15. Glass Guard
21. Overhead Light22. Overhead Rainfall Shower
WS-902AIncluded Parts
23
24
25
2627
28
16
17
18
19
20
11
12
1322
14
15
21
29
30
31
37
29. Lower Rail30. Foot Soaker31. Base Structure Frame
16. 6x25 Screws17. Lamp Board18. Right Panel Frame19. Right Back Panel20. 4x25 Self-Fixed Screws
23. Fixed Holder24. Control Panel25. Left Panel Frame26. Left Body27. Computer Relay Box28. Steam Generator
MIDDLE
37. Drain Assembly38. Steam Clean/Aromatherapy Port
Page 6
INSTALLATION MANUAL
WS-902AInstallation Diagram - Suggested Rough-In
70.9
” (1
800m
m)
17.7” (400mm)
29.7” (400mm)
49.2
” (1
250m
m)
*Water system L/R configuration may vary
*Rough-in measurements are only suggested and may be slightly altered.
Power/Telephone Socket
84.6
”(2
150m
m)
14.6
”(3
70m
m)
15.7” (400mm)
15.7” (400mm)
36.2
”
(920
mm
)36.2”
(920mm
)
INNER SIZE: 36.2” x 36.2” x 84.6”
920mm x 920mm x 2150mm
OUTER SIZE: 42.1” x 42.1” x 84.6”
1070mm x 1070mm x 2150mm
Hot Water Pipe*Cold Water Pipe*
Page 7
INSTALLATION MANUAL
WS-902AInstallation Guidelines & Warnings
1. WARNING: Read and follow all instructions.
2. DANGER: To reduce the risk of injury or death, do not permit children to use the unit unless they are closely supervised.
3. WARNING: Use this unit only for the intended purpose described in this manual; do not use attachments not recommended by the manufacturer.
4. WARNING: Never drop or insert any objects into any opening.
5. The unit is designed for indoor use ONLY.
6. The unit requires a licensed plumber for installation.
7. WARNING: The unit requires electrical power to operate and is required by code to be connected to a supply circuit that is protected by a GFCI (Ground Fault Circuit Interrupter) protected circuit by a licensed electrician. NEVER connect this unit to a circuit that is not GFCI protected. This GFCI should be provided by the installer and routinely tested (see GFCI manual for detailed instructions).
To test the GFCI:a. Push the “test” button. The GFCI should interrupt the power going
to the unit.b. Press the “reset” button and power should be restored.
If the GFCI fails to operate as described, the GFCI is defective and must be replaced. If the GFCI interrupts power to the unit without the test button being pushed, a ground fault has occurred. Discontinue use and contact your dealer or service provider.
8. WARNING: If you have a pre-existing health condition such as obesity, heart disease, high or low blood pressure, circulatory problems, diabetes, etc., consult with your physician before use. If you are pregnant or could be pregnant, do not use the unit
Page 8
INSTALLATION MANUAL
without consulting with your doctor.
9. WARNING: Observe reasonable time limits when using this product. Long exposures at high temperatures can cause high body temperatures. Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly lead to scalding or even drowning.
10. WARNING: Prolonged immersion in hot water or steam may induce hyperthermia. A description of the cause, symptoms and effects of hyperthermia are as follows:
a. Lack of awareness of impending hazard;b. Failure to perceive heat;c. Failure to recognize the need to exit the unit;d. Fetal damage in pregnant women;e. Unconsciousness and danger of drowning.
11. WARNING: The water jets produce a stream of water with relatively high pressure. Prolonged exposure of high-pressure water to a localized area of the body may cause bruising. The installation must allow for future service. The unit is designed to be modular (freestanding), meaning that the unit can be moved as a whole piece after assembly with flexible supply lines and a flexible drain. All electronic components and plumbing connections are typically located on the back wall of the unit, which in many cases is next to a service wall. In the event that service is required, a repair person will require access to these components.
12. If you are planning for a permanent installation, you must provide access to the back of the unit through some type of service panel. NOTE: Atlas International, Inc. is not responsible for and will not reimburse the cost to fix any damage or any repairs needed that are caused by the need to service the unit, even if the service
WS-902AInstallation Guidelines and Warnings
Page 9
INSTALLATION MANUAL
work required is under warranty.
13. CAUTION: A flexible drain kit is provided with the unit. The distance between the floor drain and the unit drain should not exceed 18 inches centerline to centerline.
14. CAUTION: The flexible drain should have a level or slight grade to allow free and easy flow to the floor drain. Failure to do so can cause possible leaks and flooding.
15. WARNING: It is recommended that the exhaust fan provided with the unit be vented to the outside to provide proper steam ventilation after use.
16. In order to avoid any unwanted movement, the unit should be installed on a properly supported flat and level non-slip surface.
Before starting the installation, please ensure that you have inspected all components of the unit and check for broken or damaged sections. If you find damage, please contact your dealer or the manufacturer.
These installation instructions assume you have already completed the following work:
• Rough plumbing for both the hot and cold supply lines.• Placing of the floor drain.
KL-824 Computer
System
Steam Generator
Ceiling Light
Exhaust Fan
Solenoid Valves
CPU Speaker
Rating Voltage
AC120V/60Hz DC12V DC12V DC12V
Rating Power
3000W 35W 3W 5W 10W
WS-902AInstallation Guidelines and Warnings
Page 10
INSTALLATION MANUAL
1. Power off. WARNING: Turn off the power first. For safety reasons, it is strictly prohibited to open the lid of the cleaning port during use. Otherwise, steam gas could be emitted and scald users. Please shut down all other functions before using the steam generator cleaning function.
2. Open the easy cleaning port after making sure all of the functions are turned off. Referencing the illustration on the right, locate the cleaning port and remove the lid.
3. Put the cleaning solution in the cleaning port. Pour in you premade solution. Examples include diluted citric acid or a neutral compound cleaning liquid. IMPORTANT: If the cleaning material you are using is solid, first dissolve the material with water, otherwise you risk causing blockage. The use of any other acid or alkaline compounds is strictly prohibited for use in the cleaning port.
4. Cover the lid and fasten it on. After adding the cleaning fluid, replace the lid on the cleaning cup and turn it clockwise to fasten it. This will prevent steam from emitting and scalding users.
5. After replacing the lid, press to turn on the computer system, then the [steam button] to start the steam function. The steam box will start the cleaning process.
6. Turn off the power and drain out the waste water. After 5 to 10 minutes, press the to turn off the power. The waste water will automatically drain. It will take approximately 5 minutes to drain completely.
WS-902ACleaning the Steam Generator
Page 11
INSTALLATION MANUAL
1
3
2
4
WS-902ACleaning the Steam Generator
Page 12
INSTALLATION MANUAL
1. Tray Assembly Adjust the nail under the tray to maintain balance between the tray and the surface floor.
2. Shower Body Assembly Install the left and right side shower body panels as shown, fasten with self tapping screws.
3. Attach The Shower Body Onto The Tray Secure the shower body onto the tray with machine bolts.
WS-902AStep-by-Step Installation
Page 13
INSTALLATION MANUAL
4. Attach Fixed Glass Connect the left and right fixed glass panels into the aluminum track and secure with self tapping screws.
5. Sliding Doors Assembly Put the sliding doors into the aluminum track and fasten with self tapping screws to hold in place.
WS-902AStep-by-Step Installation
Page 14
INSTALLATION MANUAL
6. Install The 4-Piece Glass Panel Onto The Tray Affix the plastic pad onto the aluminum post of the glass door and screw into place with bolts.
7. Install the RoofPlace the roof over the top of the shower and fix tightly with self tapping screws.
WS-902AStep-by-Step Installation
Page 15
INSTALLATION MANUAL
°C °C
M ºC
1. Time Adjustment “Up”
2. Temperature Adjustment “Up”
3. Overhead / Back LEDs On/Off
4. Time Adjustment “Down”
5. Temperature Adjustment “Down”
6. Fan On/Off
7. Steam On/Off
8. System Power On/Off
1
2
3
4
5
6
8
7
WS-902AControl Panel
Page 16
INSTALLATION MANUAL
Power Key Press to switch on the steam room. Press again to switch it off. The steam room will shut down in 30 minutes
automatically.
Steam Key Press . The steam generator will start working. The temperature will be shown on the control display.
Time Adjusting After the steam function is turned on, press . This will
increase the time setting.
Temperature Adjusting Key After the steam function is turned on, press °C and the
temperature will increase.
NOTE: The temperature setting ranges between 20° C and 50° C (equivalent to 68° F and 122° F). The controlled temperature tolerance is +/-3° C. The default temperature is 40° C (equivalent
to 104° F).
Vent Key Press the to turn on the vent fan. Press again to turn
off the vent fan.
Overhead/ Back Light Key Press the to turn on the overhead and back LEDs. Press
again to turn it off
WS-902AShower Operation
Page 17
INSTALLATION MANUAL
WS-902AConnection Diagram
TOP SHOWER
WATER IN
CLEAN SYSTEM
STEAM GENERATOR
EARTH LINE
DRAINAGE
STEAM OUT
FOOT MASSAGE
ACUPUNCTURESPRAYER
TO HANDHELD
Page 18
INSTALLATION MANUAL
°C °C
M ºC
WS-902AElectrical Diagram
CLEAN SYSTEM
STEAM OUTLET
WATER INLET
WATER OUTLET
CONTROL PANEL
MAIN POWER
SUPPLY IN
FAN (DC12V)
LIGHT (DC12V)
COMPUTER RELAY BOX