installation instructions zip hydrotap g4€¦ · 02 stallat stts 803341u v1.04 nov 2017 - ip g4...

32
1 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK ZIP HYDROTAP G4 INSTALLATION INSTRUCTIONS MODEL : Tap range. Filtered boiling, chilled and sparkling drinking water systems. (See table of contents for specific models). ®

Upload: others

Post on 19-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

1INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

ZIP HYDROTAP G4

INSTALLATION INSTRUCTIONS

MODEL :

Tap range.

Filtered boiling, chilled and sparkling drinking water systems.

(See table of contents for specific models).

®

Page 2: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

02 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

TAP OPTIONS

The G4 series offers a range of interchangeable taps to suit the customer's needs.

Classic range

Arc / Cube range

Elite range

All-in-One range

Mixer range

These standalone taps offer instant boiling, chilled and sparkling water* and are directly compatible with the G4 Command-Centre.

The All-in-One tap may be used as alternatives to the above HydroTap and mixer tap combinations*.

The mixer tap range may be used in conjunction with any of the above to provide mixed hot and cold water for sanitary use*.

Celsius range

The Celsius range offer instant boiling, chilled and sparkling / boiling and chilled / boiling and ambient / chilled and sparkling / chilled or boiling* water together with the an integral mixer to provide mixed hot and cold water from the mains.

*Dependant upon model purchased.

Page 3: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

03INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

TABLE OF CONTENTS

Generic installation instructionsUsing these instructions ..................................................................................................................................4Min / Max water supply pressure requirements ..............................................................................................4Special tool requirements ...............................................................................................................................4Hole & tap positioning .....................................................................................................................................5Connections ....................................................................................................................................................5Clearance envelope ........................................................................................................................................5

Tap installation Section 1 - Classic and Elite HydroTap G4 installation ..................................................................................6Section 2 - Arc / Cube HydroTap G4 installation ............................................................................................8Section 3 - Vented Mixer tap installation ........................................................................................................11Section 4 - Mains Mixer tap installation ..........................................................................................................13Section 5 - All-in-One tap ‘Mains’ installation .................................................................................................15Section 6 - All-in-One tap ‘Vented’ installation ...............................................................................................18Section 7 - Celsius tap installation ..................................................................................................................21Section 8 - Celsius All-in-One Arc tap installation ..........................................................................................25

Product informationEnd of life disposal ..........................................................................................................................................30Warranty ..........................................................................................................................................................31Contact details ................................................................................................................................................32

Page 4: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

04 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

GENERIC INSTALLATION INSTRUCTIONS

Tap installation special tool requirementsIn addition to normal tools, the following (or equivalent equipment) will be required.For the HydroTap G4, Celsius and mixer taps (for Celsius All-in-One Arc see below).

• 35mm diameter sheet metal hole punch for sinks (not supplied).• 35mm diameter hole saw for worktops (not supplied).• Nut runner tube spanner (supplied for all but Celsius & mixer taps) for fixing the tap assembly.

For the All-in-One tap & Celsius All-in-One Arc.• 50mm diameter sheet metal hole punch for sinks (not supplied).• 50mm diameter hole saw for worktops (not supplied).

• Nut runner tube spanner (not supplied for Celsius All-in-One Arc) for fixing tap assembly.Font installation special tool requirements

• Hole saw or equivalent equipment to suit surface being cut. Ø140m for Arc / Cube and Ø108mm for Classic and Elite.

Arc / Cube Elite Classic Classicvented

All-in-Onemains OR

vented

Celsius mains

Mixer tapsHydroTaps

Min / Max water supply pressure requirementsHydroTaps and Mains All-in-One & Celsius taps sparkling models..................0.25 MPa (2.5 bar) - 0.5 MPa (5 bar)HydroTaps and Mains All-in-One & Celsius taps non-sparkling models...........0.17 MPa (1.7 bar) - 0.5 MPa (5 bar)Vented All-in-One sparkling models..................................................................0.25 MPa (2.5 bar) - 0.5 MPa (5 bar)Mixer taps and Vented All-in-One non-sparkling model taps............................0.20 MPa (2.0 bar) - 0.5 MPa (5 bar)

Using these instructionsThese instructions are provided primarily to demonstrate how to install HydroTap G4 taps and do not provide sufficient information to install and commission complete HydroTap G4 systems. Please refer to all safety and installation requirements detailed in the installation instructions provided with the Command-Centre prior to any change to the complete system.

Arcmains

Cubemains

Celsius All-in-One Arc

mains

NOTE It is recommended to use a water block device to minimise the potential for water leakage in the event of a system malfunction, please refer to the Command-Centre installation instructions for details.

Page 5: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

05INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

GENERIC INSTALLATION INSTRUCTIONS

Tap Recommended dispensing

distance (mm)Elite 116

HydroTap Classic 116HydroTap Arc/Cube 171 (-174 extended)

All-in-One 211Celsius All-in-One Arc 220

Celsius - Arc/Cube 220Mixer - Arc 220

Mixer - Classic 270Mixer - Cube 220

HydroTap G4 Classic

116

!Note Celsius, All-in-One and mixer taps have spouts that swivel. All images are for illustrative purposes, to aid understanding of the system configuration, and are not prescriptive of tap positioning. Ensure that the taps are mounted in a position that allows

the water to safely drain to waste throughout the effective positional range. Ensure that taps are positioned to minimise the risks of scalding by dispensing boiling water while using the mixer tap.

Hole positioningPosition the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory, (call Zip on 0345 6 005 005).Tap positioning

ConnectionsAll plastic pipes / silicon tubes must be trimmed to size. They must have a constant fall to the Command-Centre.The connection tubes supplied with the tap head assembly CANNOT be lengthened.

Clearance envelope(see adjacent diagram)A clearance envelope around all Command-Centres must be provided to allow adequate ventilation for the safe and effective use of the HydroTap G4 system, the tap must have adequate clearance to correctly dress tubes and hoses without kink or sagging, as well as allow space for the threaded boss and the connection pipes.

Clearance envelope

535m

m

min.

300m

m 3

35mm

125

225

with

exten

sion

Dimensions in mm

Page 6: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

06 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 1 CLASSIC & ELITE HYDROTAP G4 INSTALLATION

Apply a light smearing of silicon sealant on the underside of the spacer to ensure a watertight fit.

1.2 Cut the hole & fit the spacer

Cut a Ø35mm hole in the worktop / sink.

Note Make sure the tap location will allow the tap spout to drain into the sink.

Ø35mm

EliteClassic

1.1 Tap configuration

All thread rod

Stainless steelspacer

Spider clamp

Nut

Black plastic spacer

Blue chilled pipe (chilled models)

Red boiling pipe Clear vent pipe(boiling models)

Page 7: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

07INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 1 CLASSIC & ELITE HYDROTAP G4 INSTALLATION

Black plastic spacer

1.3 Mount the tap

Pass the tubes and USB cable through the Ø35mm hole.

1.4 Secure the tap

Ø35mm holeNote Feed each of the tubes and USB cable evenly in between the legs of the spider clamp during installation.

Fit the stainless steel washer, spider clamp, and secure with nut.

Nut

Spider clamp

Stainless steel washer

1.5 Connect the water supply (detail shown, disassembled and assembled)

Braided hose to Command

-Centre(supplied)

15mm compression to ½” male BSP (not

supplied)

Filter(supplied)

Isolation valve(not supplied)

Incoming mains ambient water supply

Male - Female adaptor

(supplied)

Connect together

!Note correct filter

orientation

Incoming mains ambient water supply

Braided hose to Command

-Centre

Page 8: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

08 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 2 ARC & CUBE HYDROTAP INSTALLATION

The HydroTap Arc/Cube has a spout that may be fixed in 1 of 6 angular positions (depending on theposition of the rotary control) and fixed in one of two height positions. The spout is fixed and does not swivel.

To reduce the risk of scalding, Position *A should not be selected with any of the boiling water models. (See section 2.3).

2.1 Tap configuration

• Remove the 2 x spout locating screws and lower the spout to expose the plastic spring clip.Note The plastic spring clip has two internal dimples that may be positioned in the 6 upper or 6 lower,pre drilled holes in the spout (see diagram below & sections 2.2 & 2.3).• To reposition the spout, gently spread the plastic spring clip to release the dimples from the spout holes. When released, slide the clip on the spout so that it ends up between the two rows of holes.• Rotate the plastic clip on the spout to orient the dimples, so they

are in line with the newly selected holes.Note When determining which of the 6 holes are required for the new spout height and orientation, check the new plastic clip position will clear the undercut and that the USB lead will not be pinched, when assembled.• Slide the plastic clip up/down to engage with the selected holes,

making sure the two dimples engage simultaneously with the two selected holes.

Note The clip will not fit correctly if one dimple engagesbefore the other. Both dimples must engage at the same time.• With the clip fitted to the newly selected holes,carefully raise

the spout (ensure the USB lead is a neat fit in the undercut and is located between the open ends of the clip) until the clip locating holes are in line with the spout locating screws.

• Replace the 2 x locating screws.• If mounting on an uneven surface, apply a light smearing of

silicon sealant on the o-rings to ensure a watertight fit. (See section 2.4).

• Pass the assembly (ensuring upper o-ring, base ring and lower o-ring are in place) through the Ø35mm hole and position the tap so it discharges into the sink.

• Fit the lower rubber seal to the threaded extension.

• Secure the tap in position with the metal washer and nut.

Spout locatingscrews (2)

Undercutfor USBLower locating

positions

Plastic spring clip

Upper locating positions

Clip locating holes (2)

DimplesPlastic spring clip

!

Arc / Cube

Page 9: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

09INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 2 ARC & CUBE HYDROTAP INSTALLATION

2.2 Adjust the height (fixed position options)

50

Left hand control Right hand control

*AB

C *AB

C

2.3 Adjust the angle (fixed position options)

Cut a Ø35mm hole in the worktop / sink.Ø35mm

Upper o-ringBase ring

Lower o-ring (above worktop /sink)

Lower rubber washerMetal washer

Nut (below worktop / sink)

2.4 Cut the hole & mount the tap

Note Use the Tube kit fitting instructions supplied with the tap kit to connect the tap head assembly to the Command-Centre.

• Slide o-rings in place.• Mount tap in position on Ø35mm hole.• Slide lower rubber washer & metal washer over threaded boss, then tighten the tap nut to secure in place, do not

over tighten.

Dimensions in mm

Arc /

Cub

e 2

25 e

xtend

ed

Arc /

Cub

e 1

75 lo

were

d

Page 10: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

10 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 2 ARC & CUBE HYDROTAP INSTALLATION

2.5 Connect the water supply (detail shown, disassembled and assembled)

Braided hose to Command

-Centre(supplied)

15mm compression to ½” male BSP (not

supplied)

Filter(supplied)

Isolation valve(not supplied)

Incoming mains ambient water supply

Male - Female adaptor

(supplied)

Connect together

!Note correct filter

orientation

Incoming mains ambient water supply

Braided hose to Command

-Centre

Page 11: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

11INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 3 VENTED MIXER TAP INSTALLATION

3.1 Tap configuration

Braided hose x 3

3.2 Cut the hole & mount the tap, fit the braided hoses

Nut

Lower rubber washer

Upper rubber washer

Washer

Nut

Lower rubber washer

Upper rubber washer

Washer

White marking - Ambientmains supply

Blue marking - MIXER INon Command-Centre

Red marking - MIXER OUTon Command-Centre

Note Make sure the tap location will allow the tap spout to drain into the sink. NoteThe mixer tap requires a flow restrictor , supplied, to be fitted in the cold water supply line, from the isolation valve T-piece, to the mixer tap.(See the Command Centre Installation section of the Installation instructions for typical under-sink arrangements).• Slide upper rubber washer in place.• Mount tap in position on Ø35mm hole.• Slide lower rubber washer, metal washer then

tap nut over thread extension, then tighten the tap nut to secure in place, do not over tighten.

• Attach the braided hoses (ensure the seals on the end of the hoses are lubricated), do not over tighten.

Cut a Ø35mm hole in the worktop / sink.Ø35mm

Classic

Page 12: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

12 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 3 VENTED MIXER TAP INSTALLATION

Isolation valve(not supplied)

15mm compression to ½” male BSP (not

supplied)

White marked Braided hose to mixer tap

Braided hose to Command

-Centreinlet

Male - Female adaptor

(supplied)

T-piece(supplied)

Flow restrictor(supplied)

Male - Female adaptor

(supplied)

Filter(supplied)

Filter(supplied)

3.3 Connect the water supply (detail shown, disassembled)

Ensure flow restrictor is fitted in the mixer tap

direction

3.4 Connect the water supply (detail shown, assembled)

Incoming mains ambient water supply

Incoming mains ambient water supply

White marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Connect together

Note correct filter orientation!

Page 13: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

13INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 4 MAINS MIXER TAP INSTALLATION

Arc Cube

4.1 Tap configuration

Braided hose x 2Nut

Lower rubber washer

Upper rubber washer

Washer

4.2 Cut the hole & mount the tap, fit the braided hoses

Note Make sure the tap location will allow the tap spout to drain into the sink. • Slide upper rubber washer in place.• Mount tap in position on Ø35mm hole.• Slide lower rubber washer, metal washer then

tap nut over thread extension, then tighten the tap nut to secure in place, do not over tighten.

• Attach the braided hoses (ensure the seals on the end of the hoses are lubricated), do not over tighten.

Cut a Ø35mm hole in the worktop / sink.Ø35mm

Nut

Lower rubber washer

Upper rubber washer

Washer

Blue marking - Ambient mains supply

Red marking - Hot mains supply

Page 14: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

14 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 4 MAINS MIXER TAP INSTALLATION

4.3 Connect the water supply (detail shown, disassembled and assembled)

Incoming mains ambient water supply

Incoming mains hot

water supply

15mm compression to ½” male BSP (not

supplied)

Isolation valve(not supplied)

Blue marking - Braided hose

to tap

Red marking - Braided hose

to tap

Connect together

Incoming mains ambient water supply

Incoming mains hot

water supply

Blue marking - Braided hose

to tap

Red marking - Braided hose

to tap

Page 15: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

15INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 5 ALL-IN-ONE MAINS TAP INSTALLATION

O-ring

Base block spider

Base block nut

USB cable

Note Make sure the tap location will allow the tap spout to drain into the sink.

5.2 Cut the hole & mount the tap

5.1 Tap configuration

Cut a Ø50mm hole in the worktop / sink.Ø50mm

• Fit the o-ring to the underside of the AIO tap then pass tubes and cable through the Ø50mm hole.

• Feed each of the tubes and USB cable evenly in between the legs of the base block spider (see section 5.3).

• Fit the base block spider to the underside of the All-in-One tap.

• Clamp in position using the base block nut.

Note All silicon tubes must be cut to size. They must have a constant fall back to the Command-Centre.

All-in-Onemains

Page 16: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

16 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 5 ALL-IN-ONE MAINS TAP INSTALLATION

5.4 Connect the tap• Connect the red and clear silicone tubes & USB

cable to the Command-Centre as shown.• (Boiling,chilled and sparkling models). Connect

the blue and white plastic pipe (supplied) to the Y connector in place on the end of the blue silicone tube, then connect to the Command-Centre as shown.

• (Boiling and chilled models). Connect the blue silicone tube to the Command-Centre as shown.

• Working from inside the cupboard, attach the braided hoses to the tube extensions (ensure the seals on the end of the hoses are lubricated). Check the correct position for hot and ambient connections by matching the colours on the braided hoses with the coloured markings on the copper extension tubes. (See adjacent diagram).

• The braided hose with the blue markings must be connected to the ambient mains supply.

• The braided hose with the red markings must be connected to the hot mains supply.

• Do not over tighten the braided hoses.• Ensure that all tubes and hoses are firmly

secured.

Clear silicone tube - VENT on

Command-CentreRed silicone tube - BOILING OUT on Command-Centre

Braided hose with blue marking - ambient

mains supply.

Braided hose with red marking

- hot mains supply.

5.3 Position tubes, hoses & base block spider

Blue marking Red marking

USB cable

Blue silicone tubeRed silicone tube

Clear silicone tube

Braided hose with blue marking

Braided hose with red marking

(Boiling, chilled and sparkling

models)Blue silicone tube

Y connectorblue plastic pipe to-

STILL OUTwhite plastic pipe to- SPARKLING OUT

on the Command-Centre

(Boiling and chilled models)

Blue silicone tube to- CHILLED OUT

on the Command-Centre

(viewed from underneath)

Page 17: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

17INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 5 ALL-IN-ONE MAINS TAP INSTALLATION

Isolation valve(not supplied)

15mm compression to ½” male BSP(not supplied)

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Male - Female adaptor

(supplied)

T-piece(supplied)

Male - Male adaptor

(supplied)

5.5 Connect the water supply, disassembled

5.6 Connect the water supply, assembled

Incoming mains ambient water supply

Incoming mains ambient water supply

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Conn

ect

togeth

er

Incoming mains hot

water supply

Incoming mains hot

water supply

Red marked Braided hose to mixer tap

Red marked Braided hose to mixer tap

Male - Male adaptor

(supplied)

Filter(supplied)

Isolation valve(not supplied)

Note correct filter and male-male adaptor

orientation!

!T- piece connections must be sealed with

PTFE tape

Page 18: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

18 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 6 ALL-IN-ONE VENTED TAP INSTALLATION

6.1 Configure the tap

O-ring

Base block spider

Base block nut

USB cable

Note Make sure the tap location will allow the tap spout to drain into the sink.

6.2 Cut the hole & mount the tap

Cut a Ø50mm hole in the worktop / sink.Ø50mm

• Fit the o-ring to the underside of the AIO tap then pass tubes, hoses and cable through the Ø50mm hole.

• Feed each of the tubes and USB cable evenly in between the legs of the base block spider.

• Fit the base block spider to the underside of the All-in-One tap.

• Clamp in position using the base block nut.

Note All silicon tubes must be cut to size. They must have a constant fall back to the Command-Centre.

All-in-Onevented

Page 19: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

19INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 6 ALL-IN-ONE VENTED TAP INSTALLATION

6.4 Connect the tap• Connect the red and clear silicone tubes & USB

cable to the Command-Centre as shown.• (Boiling,chilled and sparkling models). Connect

the blue and white plastic pipe (supplied) to the Y connector in place on the end of the blue silicone tube, then connect to the Command-Centre as shown.

• (Boiling and chilled models). Connect the blue silicone tube to the Command-Centre as shown.

• Working from inside the cupboard, attach the braided hoses to the tube extensions (ensure the seals on the end of the hoses are lubricated). Check the correct position for mixer and ambient connections by matching the colours on the braided hoses with the coloured markings on the extension tubes. (See adjacent diagram).

• Connect the braided hose with the blue marking to the ‘MIXER IN’ on the Command-Centre.

• Connect the braided hose with the white marking to the flow restrictor (see section 6.5).

• Connect the braided hose with the red marking to the metal tube, with red marking then to the ‘MIXER OUT’ on the Command-Centre.

• Ensure that all tubes and hoses are firmly secured.

Braided hose connection to metal

tube - ‘MIXER OUT’ on Command-

Centre.

Braided hose with blue marking - to

MIXER IN’on Command-

Centre

Clear silicone tube - VENT on

Command-Centre

Braided hose with white marking - Flow restrictor on ambient

supply

Red silicone tube - BOILING OUT on Command-Centre

6.3 Position tubes, hoses & base block spider

White marking Blue marking

USB cable

Blue silicone tubeRed silicone tube

Clear silicone tube

Braided hose with white marking

Braided hose with blue markingBraided hose with red marking

(Boiling, chilled and sparkling

models)Blue silicone tube

Y connectorblue plastic pipe to-

STILL OUTwhite plastic pipe to- SPARKLING OUT

on the Command-Centre

(Boiling and chilled models)

Blue silicone tube to- CHILLED OUT

on the Command-Centre

Note* The All-in-One vented taps require a flow restrictor and T-piece, as supplied, to be fitted in the cold water supply line, from the isolation valve (not supplied), to the mixer tap.

(viewed from underneath)

Page 20: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

20 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 6 ALL-IN-ONE VENTED TAP INSTALLATION

6.5 Connect the water supply (detail shown, disassembled)

6.6 Connect the water supply (detail shown, assembled)

Isolation valve(not supplied)

15mm compression to ½” male BSP(not supplied)

T-piece(supplied)

Male - Female adaptor

(supplied)Filter

(supplied)

Incoming mains ambient water supply

Braided hose to Command -Centre inlet

Male - Male adaptor

(supplied)

Male - Male adaptor

(supplied)Filter

(supplied)

Flow restrictor(supplied)

Male - Female adaptor

(supplied)

White marked Braided hose to mixer tap

Conn

ect

togeth

er

Incoming mains ambient water supply

White marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Ensure flow restrictor is fitted in the mixer tap

direction

Note correct filter and male-male adaptor

orientation!

!T- piece connections must be sealed with

PTFE tape

Page 21: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

21INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 7 CELSIUS TAP INSTALLATION

220

330

251

Ø23

Ø49

22040

2

257

Ø23

Ø49

ArcCube

Celsius

7.1 Dimensions

• Slide upper rubber washer in place on underside of tap.• Mount tap in position on Ø35mm hole.• Slide lower rubber washer, metal washer then tap nut over the threaded boss, then tighten the tap nut to

secure in place, do not over tighten.• Match the colour markings on the braided hoses to those of the copper extension tubes. Attach the

braided hoses (ensure the seals on the end of the hoses are lubricated), do not over tighten.• Attach the braided hoses to the mains hot and ambient supply (see sections 7.5, 7.6). • Attach the USB connector to the corresponding connector from the Command-Centre.

7.2 Cut the hole & mount the tap (see sections 7.3, 7.4)Cut a Ø35mm hole in the worktop / sink.

Note Make sure the tap location will allow the tap spout to drain into the sink.

Ø35mm

Dimensions in mm

Page 22: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

22 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 7 CELSIUS TAP INSTALLATION

Fit the brass and rubber washers and secure with

brass nut.

Ø35mm hole

7.3 Connect the Chilled and sparkling + mixed hot & cold tap

Nut

Brass washer

Lower rubber washer

Upper rubber washer

USB lead

Chilled pipe

Sparkling pipe

Mains hot and cold braided hoses

Vent

Assembled Disassembled

Chilled sparkling models • Attach the blue plastic pipe (supplied) to the Y-connector (on the end of the blue silicone tube from the Celsius

tap), then attach to STLL OUT on the Command-Centre.• Attach the white plastic pipe (supplied) to the Y-connector (on the end of the blue silicone tube from the Celsius

tap), then attach to SPARKLING OUT on the Command-Centre.

Page 23: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

23INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 7 CELSIUS TAP INSTALLATION

7.4 Connect the Boiling + mixed hot & cold tap installation Chilled + mixed hot & cold tap installation

Nut

Brass washer

Lower rubber washer

Upper rubber washer

USB lead

Chilled (blue) or Boiling (red) pipe

depending on model

Vent (clear) pipe

(Boiling models)Mains hot and cold braided hoses

Vent

Fit the brass and rubber washers and secure with

brass nut.

Assembled Disassembled

Boiling models• Attach the red silicone tube to the BOILING OUT on the Command-Centre.• Attach the clear vent tube to the VENT outlet on the Command-Centre.Chilled models• Attach the blue silicone tube to CHILLED OUT on the Command-Centre.

Page 24: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

24 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 7 CELSIUS TAP INSTALLATION

Isolation valve(not supplied)

15mm compression to ½” male BSP(not supplied)

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Male - Female adaptor

(supplied)

T-piece(supplied)

Male - Male adaptor

(supplied)

7.5 Connect the water supply (detail shown, disassembled)

7.6 Connect the water supply (detail shown, assembled)

Incoming mains ambient water supply

Incoming mains cold

water supply

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Conn

ect

togeth

er

Incoming mains hot

water supply

Incoming mains hot

water supply Red marked Braided hose to mixer tap

Red marked Braided hose to mixer tap

Male - Male adaptor

(supplied)

Filter(supplied)

Isolation valve(not supplied)

Note correct filter and male-male adaptor

orientation!

!T- piece connections must be sealed with

PTFE tape

Page 25: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

25INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

SECTION 8 CELSIUS ALL-IN-ONE ARC MAINS TAP INSTALLATION

!Note Celsius All-in-One taps have spouts that swivel. All images are for illustrative

purposes, to aid understanding of the system configuration, and are not prescriptive of tap positioning. Ensure that the taps are mounted in a position that allows the water to safely drain to waste throughout the effective positional range. Ensure that taps are positioned to minimise the risks of scalding by dispensing boiling water while using the mixer tap.

Dimensions in mm

Hot & ColdWater Outlet

Chilled WaterOutlet

Boiling WaterOutlet

Steam VentOutlet

Chilled / Sparkling / Filtered

8.1 Dimensions and hole positioning

8.2 Outlet configuration

22043

9.525

825

5

Ø43

51

151

85

7373

Page 26: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

26 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

CELSIUS ALL-IN-ONE ARC MAINS TAP INSTALLATION

USB cable

Mixed water braided hoseHOT mains braided hose

AMBIENT mains braided hose

Brass nut

O-ring

Rubber washerMetal washer

Threaded boss

3 way silicone tube

Note Make sure the tap location will allow the tap spout to drain into the sink.

Cut a Ø50mm hole in the worktop / sink.Ø50mm

• Fit the o-ring to the underside of the AIO tap then pass tubes, cable and mixed water braided hose through the Ø50mm hole.

• Fit the large rubber and metal washers over the threaded boss (on the underside of the worktop).

• Clamp in position using the brass nut.

Note All silicon tubes must be cut to size. They must have a constant fall back to the Command-Centre.

8.3 Tap configuration

8.4 Cut the hole & mount the tap

Page 27: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

27INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

CELSIUS ALL-IN-ONE ARC MAINS TAP INSTALLATION

Brass nut

Braided hose for mixed water

3 ways multi channel

silicone tube

Boiling outlet

Chilledoutlet

Steamvent

BOTTOM END OF 3-WAY SILICONE TUBE

Connect tap to Command-Centre via 3 stainless steel tubes

TOP END OF 3-WAY SILICONE TUBE

Steamvent

Boiling outlet

Chilledoutlet

8.5 Connect the tap, boiling and chilled, boiling and ambient models

Braided hose with red

marking - hot mains supply.

Braided hose with blue

marking - cold mains supply.

USB plug, connect to Command-Centre

Push fit straight connector

(supplied), connect to mixed water braided hose.

Red silicone tube -To BOILING OUTLET on

Command-Centre

Blue silicone tube -To CHILLED or AMBIENT OUTLET on

Command-Centre

Clear silicone tube - To VENT on Command-

Centre

! Do not over tighten the braided hoses. Ensure that all tubes and hoses are firmly secured.

Fit braided hoses to tap connections in the orientation

shown.

3 way silicone tube from tap

Page 28: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

28 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

CELSIUS ALL-IN-ONE ARC MAINS TAP INSTALLATION

Brass nut

USB plug, connect to Command-Centre

Red silicone tube - To BOILING OUTLET on

Command-Centre

Push fit straight connector, connect

to mixed water braided hose.

Braided hose for mixed water

To CHILLED OUTLET on Command-Centre

Clear silicone tube -To VENT on Command-Centre

3 ways multi channel

silicone tube

Boiling outlet

Chilledoutlet

Steamvent

BOTTOM END OF 3-WAY SILICONE TUBE

TOP END OF 3-WAY SILICONE TUBE

Steamvent

Boiling outlet

Chilled/Sparklingoutlet

8.6 Connect the tap, Boiling chilled & sparkling models

To SPARKLING OUTLET on Command-Centre

Braided hose with blue

marking - cold mains supply.

! Do not over tighten the braided hoses. Ensure that all tubes and hoses are firmly secure.

Fit braided hoses to tap connections in the orientation

shown.

3 way silicone tube from tap

Connect tap to Command-Centre via 3 stainless steel tubes

Braided hose with red

marking - hot mains supply.

Page 29: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

29INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

CELSIUS ALL-IN-ONE ARC MAINS TAP INSTALLATION

Isolation valve(not supplied)

15mm compression to ½” male BSP(not supplied)

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Male - Female adaptor

(supplied)

T-piece(supplied)

Male - Male adaptor

(supplied)

8.7 Connect the water supply (detail shown, disassembled)

Incoming mains ambient water supply

Conn

ect

togeth

er

Incoming mains hot

water supplyRed marked Braided hose to mixer tap

Male - Male adaptor

(supplied)Filter (supplied)

Isolation valve(not supplied)

8.8 Connect the water supply (detail shown, assembled)

Incoming mains cold

water supply

Blue marked Braided hose to mixer tap

Braided hose to Command -Centre inlet

Incoming mains hot

water supply

Red marked Braided hose to mixer tap

Note correct filter and male-male adaptor

orientation!

!T- piece connections must be sealed with

PTFE tape

Page 30: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

30 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

END OF LIFE DISPOSAL

The use of this crossed out wheeled bin logo indicates that electrical and electronic products needs to be disposed of separately to any other household waste.Within each of the European Union member countries, provisions have been made for collection and recycling of unwanted electrical and electronic equipment. In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service on 0345 6 005 005 for advice.

Page 31: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

31INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

WARRANTY

Refer to the Command-Centre instructions for warranty information.

Page 32: INSTALLATION INSTRUCTIONS ZIP HYDROTAP G4€¦ · 02 STALLAT STTS 803341U V1.04 NOV 2017 - IP G4 TAP RANGE T ST TEL 0345 6 005 005 EMAIL SERVICE@IPINDUSTRIES .CO.U TAP OPTIONS The

32 INSTALLATION INSTRUCTIONS 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE

TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK WWW.ZIPWATER.CO.UK

Zip Water UK14 Bertie Ward Way, Dereham, Norfolk NR19 1TE

0345 6 005 005 [email protected]

www.zipwater.co.uk