installation and wiring guide - salus controls

2
S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N N L N L N L L L N P1 UT P2 UT AV 1 2 3 4 5 GROUP2 HTRS230 GROUP THERMOSTAT 1 HTRP230 GROUP CONTROL THERMOSTAT 1 HTRS230 GROUP THERMOSTAT 2 HTRS230 GROUP THERMOSTAT 3 HTRP230 GROUP CONTROL THERMOSTAT 2 HTRS230 GROUP THERMOSTAT 1 GROUP1 STANDALONE HTR230 STANDALONE HTR230 SUPPLIED CABLES UNDERFLOOR HEATING MANIFOLD EXTERNAL CLOCK SUPPLY External power supply Optional boiler connection 0 Volt connection 1.5MM2 CABLE (INSTALLER SUPPLIED) OPTIONAL EXTERNAL CLOCK N S2 S1 NSB SL L THERMOSTA T A T1 S1 NSB SL L THERMOSTA T N S2 T 1 T 2 S1 NSB SL L N THERMOSTAT 3 N S2 T 2 T N S2 S1 NSB SL L N T 2 THERMOSTAT 1 KL08NSB Installation and Wiring Guide www.salus-controls.com Technical Helpline +44 (0) 1226 323 961 These instructions apply to the SALUS model stated above. Warning This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. For PDF Installation guide go to www.salus-controls.com Warning Always isolate the AC mains supply before installing or working on any components that require 230 V AC 50Hz supply. Warning The earth terminals on the KL08NSB are for earth parking only. These terminals provide no earth protection. Meets the following EC Directives Electro-Magntic Compatibility directive 2014/30/EU Low-voltage Directive 2014/35/EU Restriction of Hazardous Substances Directive 2011/65/EU Maintaining a policy of continued product development SALUS Controls plc reserves the right to change specification, design and materials of products listed on this installation guide without prior notice. Issue Date: October 2014 Document Number 00106

Upload: others

Post on 06-Feb-2022

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation and Wiring Guide - SALUS Controls

S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N S2 S1 NSB SL L N

N L

NL

NL

L

L N

P1 UT P2 UT

PÅ AV

1 2 3 4 5

GROUP2

HTRS230GROUP

THERMOSTAT 1

HTRP230GROUP CONTROL

THERMOSTAT 1

HTRS230GROUP

THERMOSTAT 2

HTRS230GROUP

THERMOSTAT 3

HTRP230GROUP CONTROL

THERMOSTAT 2

HTRS230GROUP

THERMOSTAT 1

GROUP1

STANDALONEHTR230

STANDALONEHTR230

SUPPLIED CABLES

UNDERFLOOR HEATING MANIFOLD

EXTERNAL CLOCK SUPPLY

External power supply

Optional boiler connection

0 Volt connection

1.5MM2 CABLE (INSTALLER SUPPLIED)

OPTIONAL EXTERNAL

CLOCK

N S2 S1 NSB SL L

THERMOSTATAT 1

S1 NSB SL L

THERMOSTAT

N S2

T 1 T

2 S1 NSB SL L N

THERMOSTAT 3

N S2

T 2 T

N S2 S1 NSB SL L N

T 2 THERMOSTAT 1

KL08NSB Installation and Wiring Guide

www.salus-controls.com Technical Helpline +44 (0) 1226 323 961

These instructions apply to the SALUS model stated above.

Warning This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution.

For PDF Installation guide go to www.salus-controls.com

Warning Always isolate the AC mains supply before installing or working on any components that require 230 V AC 50Hz supply.

Warning The earth terminals on the KL08NSB are for earth parking only. These terminals provide no earth protection.

Meets the following EC Directives• Electro-Magntic Compatibility directive 2014/30/EU• Low-voltage Directive 2014/35/EU• Restriction of Hazardous Substances Directive 2011/65/EU

Maintaining a policy of continued product development SALUS Controls plc reserves the right to change specification, design and materials of products listed on this installation guide without prior notice.

Issue Date: October 2014 Document Number 00106

Page 2: Installation and Wiring Guide - SALUS Controls

KL08NSB Installation and Wiring Guide

www.salus-controls.com Technical Helpline +44 (0) 1226 323 961

1 Remove the plastic cover. Open (and close) the four white screws with a quarter turn only. Note that screws on opposite sides turn in the opposite direction.

2 Remove the white terminal connection board.

3 Attach the back of the KL08NSB to the DIN rail or wall.

5 Clip all power and thermostat cables into their correct positions. The following shows the power, zone 1, and 2 thermostat cables in position:

6 Replace the white terminal connection board.

7 Bend over and push the power wires into the round power holes.

8 Bend over and push all thermostat wires into the round holes at the top of the KL08NSB.

9 Push the actuator wires into the round holes at the bottom of the KL08NSB. You can connect up to four actuators in each zone.

10 Make sure there is a fuse in thefuse holder.

11 Set the actuator and boiler delay jumpers at the top right of the KL08NSB.

12 Push in the wires for a pump and boiler (if applicable) at the bottom right of the KL08NSB.Pump and boiler switching is volt free.

13 Attach the red strain-relieving strip using the three screws to secure the pump and boiler wires to the bottom side of the KL08NSB.

14 Replace the plastic cover.

15 Switch on mains power supply to the unit. The red LED comes on.

LED indicationsName Colour Meaning

Power • KL08NSB is supplied with 230V powerZone 1 actuators • Demand from zone 1 thermostat: actuator openZone 2 actuators • Demand from zone 2 thermostat: actuator openZone 3 actuators • Demand from zone 3 thermostat: actuator openZone 4 actuators • Demand from zone 4 thermostat: actuator openZone 5 actuators • Demand from zone 5 thermostat: actuator openZone 6 actuators • Demand from zone 6 thermostat: actuator openZone 7 actuators • Demand from zone 7 thermostat: actuator openZone 8 actuators • Demand from zone 8 thermostat: actuator openPump • Pump onBoiler • Boiler on

Installing and Connectingthe KL08NSBUse the KL08NSB wiring centre to simply and safely connect thermostats and corresponding thermal actuators. It can have three different physical configurations:

• Two groups of V30 thermostats, each group having up to four thermostats.

• Three groups of V30 thermostats with a KL04NSB extension attached, each group having up to four thermostats.

• A VS30 master thermostat controlling up to seven VS35 slave thermostats. For this configuration, you must make a bridge between grey positions 1-4 and 5-8. If a KL04NSB extension is attached to the KL08NSB, this is not included in this configuration and another VS30 master thermostat will control the VS35 slaves connected to the KL04NSB on zones 9 to 12.

Install the KL08NSB only in dry and closed interior rooms. Relative air humidity in the room may not exceed 95%. Clean the KL08NSB only with a dry and soft cloth. Do not use solvents or aggressive cleaning agents.

4 Cut the power, thermostat anddevice cables to length.

Device

Power/Thermostat

50mm

110mm

10mm

10mm

Type of ActuatorThe default setting for the type of actuator is normally closed (NC). To change this setting to normally open (NO), carefully remove the jumper and re-insert it in the other position as shown below. Note that the actuator setting and thermostat setting must be the same.

Jumper Settings/Positions for Pump/Boiler On/Off DelayThe pump/boiler on delay and the pump off delay are fixed at three minutes. The default setting for the boiler off delay is also three minutes, but can be changed to 15 minutes. To do this, carefully remove the jumper and re-insert it in the other position as shown below:

Note: the red reset button to the right of the boiler delay jumpers. Using a suitable tool, press this button at any time to reset the KL08NSB back to factory default settings.