innovative waste combustion system with global patent air-curtain technology : cds incinerator
TRANSCRIPT
0
CDS COMBUSTION INCINERATOR & PLANT SYSTEM FOR MEDICAL WASTE
INNOVATIVE WASTE COMBUSTION TECHNOLOGY
Mr. EVAN RYU (Overseas Marketing) / +82 10 6357 1398 / [email protected] #1218 Rosedeil Office, 724 Suseo-dong Gangnam-gu Seoul, Republic of Korea
1
INTRODUCING OUR TECHNOLOGY
Innovative AIR-COUTAIN combustion system:
Over 40 years’ study on combustion system, Mr. Kim brothers invented innovative combustion system
which has more than 90% efficiency with our AIR-CURTIAN technology. This AIR-COURTAIN prevent
burning heat come out of chamber, and let the burning heat go around inside so the inside heat
temperature can go up to 2,000 degrees(C).
This technology makes many kinds of FIRE RETARDANT WASTE and MEDICAL WASTE burn out
almost complete combustion. (Over 90% energy efficiency)
< Concept features of our patent AIR-CURTAIN combustion system >
The air waved curtain let the burning heat circle around in the middle, making all the waste completely combusted.
< The CDS system in the whole waste Combustion & Energize process >
Over the whole waste(ex: for medical) combustion, our CDS system(A) will take the smallest install space
among all the other combustion chambers
In the section (B), you can install steam boiler system and electricity generator plant facility.
2
WHY OUR WASTE COMBUSTION SYSTEM EXCEED OTHERS?
Our patent air-curtain combustion system extremely exceeds
all the other conventional combustion systems like STOKER combustion.
No need for firebricks in the combustion system
No emission of noxious gases, smoke & odour
No large space to install the system
No clinker comes out after the burn
Over 90% burn-out of waste
< WORLDWIDE PATENT in waste combustion system >
The patents for our system is registered over 12 countries: Korea, USA, Canada, Japan, China,
German, France, Switzerland, Russia, Australia, New Zealand, Hong Kong
Some facts comparing with other combustion systems
This table is relative evaluation for combusting same amount and type of waste
For the Chamber size comparison: Supposing the size of CDS combustor is ‘1’
3
Medical Waste Incinerator & Energy Plant
BIO HAZARD & FIRE RETADANT WASTES
How to dispose Cost-efficiently & Environmental-friendly & Energy reuse
Our Medical Waste combustion system
5 tons for 10 Hours / Temperature up to 2,000 degrees Celsius or more
Volume of controlled burn medical wastes with a capacity of
5 tons per day for 10 hours to burn in the combustion (300kg per hour)
temperature range up to 2000 degrees Celsius or more
No need of FIREBRICKS due to our innovative air-curtain technology
Incinerator does not need the firebricks inside the burner because of air-curtain between the pillar of
fire and the wall of the burner.
Incinerator machine has a good efficiency up to 90%
Virtually smoke and odour free.
Rapid warm up to operating temperature and Easy-to-Operate system
The medical waste is burning by itself without oil and possible to see the inside by window on the
incinerator.
Our system can burn the wastes without oil during burning. Just supply the air contained oxygen into
the combustor by motor. But on the starting time, use just few oil for starting. In the future the thermal
energy from the combustion system can supply to any other place where need the steam energy like
house, factory, building, school, hospital or company. It needs to attach the turbine system. It can change
the electrical energy also. So the Medical wastes can change to energy. The turbine system attached
refer to the below picture.
4
< Possible Power Plant structure with our CDS combustion system >
The Combustor has been designed to have a good transfer oxygen system. The combustor can heat up to 2,000 degree Celsius. Due to the high temperature, the pollution gas emission is very little. Inside of combustor doesn’t need firebricks on the inside wall so it can make faster cooling and starting than other types.
Light ash residuals from the burning can be used to fill land. Fuel energy saving (without Oil or other Fuel during burning) and can make the Electronic
Power if connected the turbine system in the future. Enhance the quality of life for members of the community as a result of good health and safe from direct and indirect harms of waste.
< POSSIBLE SPECIFICATION OF POWER PLANT WITH CDS SYSTEM>
The actual specification and detail system requirements are depending on situation
NO 5 TON / DAY SPECIFICATION
1 Model(CDS-5000) 5 Tons per day(10 hours)
2 IN-PUT Capacity 25KVA,MAX.(25KW)
3 IN-PUT Voltage 380Vх3∅х4Cable
4 IN-PUT Current 35A,MAX.
5 Duty Cycle 100%
6 First Burning Chamber 0.95㎥(=125kg)
7 Second Burning Room
8 Third Burning & Cooling Room
9 Scattering Dust Cyclone
10 FD FAN 30HPх380Vх3Ø(50Hz)
11 Operating Controller Inverter-20kw
12 Temperature Sensor A'ssy 2000°C, MAX.
13 Burning System Base
14 Burning Capacity MAX 125kg / 1chamber
15 Burning Time Average 30min.
16 Operating Capacity 5,000kg/Day(10h)
17 Price To be discussed (Around 220,000 USD / Ex-Work)