A FAMILY OF INNOVATIVE
CEREBROVASCULAR MICROCATHETERS
COURIER Enzo
COURIER
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
2/8
Setting a New Standard
With its unique combination of deflectability and stability, COURIER Enzo sets a new standard
for microcatheters.
Dial-In Stability
Enzos active tip deflection allows better control of the desired stability to reduce kickbackduring embolization. This can help in challenging cases with acute turns and small or densely
packed aneurysms in which catheter access is tenuous.
Pack. REDIRECT. Pack.
The ability to deflect Enzos tip during the procedure can facilitate the redirection
of embolics, allowing more control over the positioning and packing of coils,
especially in large or multilobular aneurysms. This could eliminate the need toremove, reshape, and reposition the cathetersaving valuable procedure time.
The Enzo tip remained stable inside an
acutely angled 4 mm supraclinoid ICA
aneurysm throughout the procedure.
The Enzo tip was redirected to coil the upper and lower lobes progressively in a complex upper basilar aneurysm.
Upper lobe coiled Lower lobe coiledPre-coiling
Pre-coiling Post-coiling
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
3/8
90 cm Shaft Marker:Allows for
expedited microcatheter insertion
into a guiding catheter for reduced
fluoroscopic use.
Two Radiopaque Markers: Platinum
radiopaque markers, 3 cm apart, enhance
fluoroscopic visibility of the catheter tip.
Flexible and Stable Distal Shaft
Segment: Micrus proprietary
design and fabrication techniques
result in superior tip shaperetention and stability* to reduce
kickback.
Proximal Shaft: Multiple slender
stainless-steel ribbons crisscross
to form a dense proximal braided
section, providing better catheter
pushability and control.*
Shaft Construction: Multilayer
shaft construction creates smooth
transition zonesfrom a soft, low-
profile distal segment with enhanced
resistance to ovalization to a
supportive proximal end.
1.8 F Distal OD:
Helps navigate through
stent cells.
COURIER helped treat a giant 3 cm
pericallosal artery aneurysm. It held a
J-curve shape and was stable through
a high degree of tortuosity.
Exceptional Trackability.
Preferred Outcomes.
COURIER Microcatheters feature the most pushable proximal shaft*, a flexible distal
segment, and a patented hydrophilic coating that ensure excellent trackability to help
you get thereand provide excellent stability within the lesion to help you stay there.
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
4/8
Visionary Innovation. Unmatched Performance.
COURIER Enzo brings a whole new level of functionality to neurovascular microcatheters. The secret lies
in the unique actively deflectable tip that allows in vivocontrol of the tip shape via Enzos ergonomic hub.
COURIER Enzos tip can be deflected up to 90 degrees (from straight) in opposing directions. This permits
a greater level of control over catheter and embolic placement.
Ergonomic Deflection Knob:
Allows in vivocontrol of Enzos tip,
deflectable up to 90 degrees (from
straight) in opposing directions.
In this 4 mm posterior communicating artery aneurysm
case, notice how sharply Enzo deflected into the large
neck. It managed to steadily hold this tenuous access
point throughout the treatment. Later, Enzo aided coiling,
deflecting away from the dome.
The Revolutionary
COURIER Enzo Microcatheter
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
5/8
*Data on file, Micrus Endovascular Corporation.
COURIER shape retention provides
better shape stability inside the lesion.
Additional Shape Loss Over 3 Hours
30
0
Shape
Retention
(Degrees)
Time (Hours)
0.5 1 1.5 2 2.5 3
60
45
90
75
Product A Product CProduct BCOURIER 170
Product A Product BCOURIER 170
90
45
0
Product C
89
81
7064
InitialShape
(Degrees)
All microcatheters were shaped to 90 degrees. Starting shape
is shown after mandrel was removed.
Increasing Initial Shape Loss
25
19
8
COURIER Straight and
Preshaped Microcatheters
Shape It. Get There. Stay There.
The unique design of COURIER Microcatheters delivers the ideal balance of form and function. The result is a rich set of
features and an optimal blend of access and support that are particularly suited for distal accessbecause getting there
is only half the challenge.
Endurance Technology Beyond Just Shape Retention
COURIER features our exclusive Endurance Technology, integrating all layers of the microcatheter into a well-balanced
laminate. The result is amazing shapability and retention of the tip shape during even the most complex, lengthy procedures.
Shapability
COURIERs superior shapability* allows you to match the anatomy one to one, reducing the need to overshape.
Shape RetentionCOURIER retained over 90% of its initial tip shape after 3 hours of simulated use*.
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
6/8
Avenue des Baumettes 7
1020 Renens
Switzerland
T +41.21.631.3434
F +41.21.631.3444
821 Fox Lane
San Jose, CA 95131
United States
T 408.433.1400
F 408.433.1401
1st Floor, Unit 4
Stansted Courtyard
Takeley
Bishops Stortford
Essex
CM22 6PU
United Kingdom
T +44.800.612.6363
F +44.800.612.8484
CAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.
MICRUS, COURIER, and the M logo are registered trademarks of Micrus Endovascular Corporation. Enzo and Endurance Technology are trademarks of Micrus Endovascular Corporation.
Other product names or marks are the property of their respective owners.
2007 Micrus Endovascular Corporation. All rights reserved. P/N 50885-01 REV A
170170
190
CATALOG NUMBER DESCRIPTION PROXIMAL/DISTAL ID TOTAL/ PROXIMAL OD/
USABLE LENGTH LOW-PROFILE DISTAL OD
MST170000-00 Straight .0170 / .0170 156 cm / 150 cm 2.3 F ( .76 mm) / 1.8 F ( .59 mm)
MPS170045-00 45 .0170 / .0170 156 cm / 150 cm 2.3 F ( .76 mm) / 1.8 F ( .59 mm)
MPS170090-00 90 .0170 / .0170 156 cm / 150 cm 2.3 F (.76 mm) / 1.8 F (.59 mm)
Compatible with embolics including Micrus 10, 14, and 18 System Microcoils*
Compatible with embolics including Micrus 14 and 18 System Microcoils*
170170
190
Minimum guiding catheter ID:
COURIER 170 Microcatheters: .035 / .889 mm
COURIER 190 Microcatheters: .042 / 1.067 mm
COURIER Enzo Microcatheters: .050 / 1.27 mm
Hydrophilic coated length (distal to proximal): 100 cm
Recommended guidewire diameter: .014
* Please refer to the appropriate Instructions for Use for compatibility information.
CATALOG NUMBER DESCRIPTION PROXIMAL/DISTAL ID TOTAL / PROXIMAL OD/
USABLE LENGTH LOW-PROFILE DISTAL OD
MSH170000-00 Deflectable .0170 / .0170 160 cm / 150 cm 3.0 F (1.0 mm) / 2.9 F (.97 mm)
CATALOG NUMBER DESCRIPTION PROXIMAL/DISTAL ID TOTAL/ PROXIMAL OD/
USABLE LENGTH LOW-PROFILE DISTAL OD
MSH190000-00 Deflectable .0190 / .0190 160 cm / 150 cm 3.1 F (1.03 mm) / 3.0 F (1.0 mm)
CATALOG NUMBER DESCRIPTION PROXIMAL/DISTAL ID TOTAL/ PROXIMAL OD/
USABLE LENGTH LOW-PROFILE DISTAL OD
MST190000-00 Straight .0190 / .0190 156 cm / 150 cm 2.4 F (.79 mm) / 1.9 F (.63 mm)
MPS190045-00 45 .0190 / .0190 156 cm / 150 cm 2.4 F (.79 mm) / 1.9 F (.63 mm)
MPS190090-00 90 .0190 / .0190 156 cm / 150 cm 2.4 F (.79 mm) / 1.9 F (.63 mm)
Compatible with embolics including Micrus 10, 14, and 18 System Microcoils*
Compatible with embolics including Micrus 14 and 18 System Microcoils*
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
7/8
Courier EnzoTM Increases
Packing Density
The Courier Enzo deflectable tip microcatheter can distribute coils within
an aneurysm to achieve improved packing density. 3 INRs evaluated its
performance in an in-vitro study under angiography. 10 silicone aneurysms,
each 10mm in diameter, were coiled using Courier Enzo and a conventional
competitive microcatheter (Product A). The end point was when the micro-
catheter was kicked out of the aneurysm.
Enzo showed a statistically significant 9% increase in packing density as
compared to Product A. Micrus Cerecyte Microcoils were used in both
arms. Enzo consistently demonstrated higher packing density.
* Study performed at Stanford University Medical Center. Data on file,
Micrus Endovascular Corporation
* Presidio, Helipaq, Ultipaq and Cashmere Microcoils were
used during the study
Courier Enzo allows better control of the microcatheter tip.
This helps direct the coils and find empty spaces within
the interstices of the coil mass, especially during the final
stages of coiling.*
Better stability provides
higher packing density
Redirecting Enzos tip
resists catheter kickback
The Courier Enzo is designed to deflect. It provides
stability by resisting being kicked out of the lesion.
This can provide consistently higher packing density.
* Please refer to IFU for proper handling instructions.
ENZO Product A
3O%
O%
1O%
4O%
5O%
2O%39.1%
0.9%
29.6%
7.4%
Packing density with Enzo and Product A
-
7/31/2019 Innovative, Micro Catheters - Unknown - Setting a New Standard
8/8
Packing Density Can Affect
Re-treatment Rates
P/N 51040 02 R A
www.micruscorp.com
CAUTION:Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.
MICRUS, the M logo, Courier and Cerecyte are registered trademarks of Micrus Endovascular Corporation.
Enzo is a registered trademark of Micrus Endovascular Corporation.
2008 Mi E d l C i All i h d
There is a significant correlation
between embolized volume and
stability of embolized aneurysms.
Embolized volume is a more objective
index than is subjectively angiographic
percentage occlusion.2
The CARAT study reported that the
degree of aneurysm occlusion after
the initial treatment is a strong predictor
of the risk of subsequent rupture in
patients presenting with subarachnoid
hemorrhage, which justifies attempts
to completely occlude aneurysms.1
Non-procedural re-rupture from the index aneurysm by degree of occlusion*
Coiling
* Based on Kaplan-Meier analysis and the log-rank test with censoring at time of rupture,
retreatment, or loss to follow-up.
Overall
Degree of Occlusion
Complete (100%)
Small residual neck
(91%-99%)
Residual neck
(70%-90%)
Partial (