innovation, performance, and more ......by placing biocompatibility at the heart of its innovation...
TRANSCRIPT
INNOVATION, PERFORMANCE, AND MORE BIOCOMPATIBILITY!
JAN 2020
ISO 13485
Sources : • Genotoxicity and cytoxicity of 2-hydroxyethyl methacrylate - Elzbieta pawlowska et ol - Mutation Research 696 (2010) 122-129 • Cytoxicity of the dental composite component TEGDMA and selected metabolic by-products in human pulmonary cells - J Emler et ol• TEGDMA and Bisphenol-A : the same level of risk in dental medicine ? - Jean-Marc Meyer - Autredent, No 56, pages 81-86, 2010
By placing biocompatibility at the heart of its innovation strategy, the French laboratory ELSODENT stands out with new dental materials that are always more efficient and safer for patients.With a 25-years clinical experience, ELSODENT designs and manufactures, in France, improved biocompatibility dental products. More health-friendly for patients, the product range also present unique clinical and physico-chemical qualities to meet the requirements of dentists in terms of saving time and economy.
The origin of BIO+ ELSODENT range
Alarmed by the potential toxicity of dental products commonly used and sold on the market, the French laboratory ELSODENT wanted to address the major concerns of dentists but also those growing health-conscious patients, by developping more health-friendly dental products.
Scientific background of the BIO+ rangeThese questions about dental products go back decades. During the 90s, amalgams, more commonly known as «fillings», containing mercury, were already challenged by a part of the scientific community.
Replaced today by composites, these new materials are now getting contested because of their significant potential toxicity. With formula based on compounds like TEGDMA, HEMA & BisGMA, these dental products can, under specific conditions, release in the mouth toxic substances for our organism and carcinogenic, like Formaldehyde and Bisphenol A.
Dental revolution
Based on its advanced clinical, technical and scientific skills, our laboratory has developed a complete range of composites, resins, adhesives agents, cements,... formulated without addition of these potentially dangerous monomers such as TEGDMA, HEMA, or BisGMA and its derivatives.Our formulations now offer non-hydrolysable substitution monomers issued from our R&D programs.Innovative and performant, the BIO + range is ideally suited to the needs of both dentists and patients, since these products benefit from improved biocompatibility while maintaining exceptional clinical and physicochemical properties.They are easily identified by the BIO+ logo and are presented in recyclable and / or recycled packaging.
INNOVATION, PERFORMANCE & CLINICAL FEATURES
BIOCOMPATIBILITY Formulation without addition ofBisGMA, TEGDMA, HEMA
Monomers currently used in dentistry and asssociated risks*
BisGMA (Bis Phenol Glycidyl Metacrylate)
Basic resin for composites and others dental products, synthetized from Bisphenol A (BPA) and Glycidyl Methacrylate.Also contains free BPA, quickly released by the products in the mouth, and found in saliva a few hours after use. When hydrolyzed, the product releases Bisphenol A.
TEGDMA (Triethyleneglycoldimethacrylate)
Resin used to make BisGMA more flowable. Beyond its intrinsic toxicity, its lipophilic nature allows it to easily penetrate cell membranes and interact with DNA. Easily hydrolysed by salivary enzymes to produce Formaldehyde.
HEMA (Hydroxy Ethyl Metacrylate)
A short-chain of resin, which easily crosses cell walls and can,like TEGDMA, interact with DNA. Interfering in DNA repair, this can lead to mutations and cancers. Easily hydrolysed by salivary enzymes to produce Formaldehyde.
*Sources : Mol Biol Rep (2012) 39:1561–1574 | Dental Materials Journal 19 (2) 139-152, 2000 | Mutation Research 696 (2010) 122–129 | Dental Materials 24 ( 2008) 1670–1675
Innovative and performant dental products, made in France and formulated without the addition of potentially toxic resins such as HEMA, BisGMA, TEGDMA.
This is the core of ELSODENT BIO+ approach when designing dental consumables with improved biocompatibility to offer more health-friendly products.
3www.elsodent.com
PF SEAL
PUREFILL FLOW
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
REFERENCES & DESCRIPTION
PUR-F-4-* 2 x 1,2 ml (2g) syringes + 10 tips.VITA shades:A1/B1 - A2 - A3 - A3,5 - B2
IR-100 100 pink needle tips. Gauge 18.*Shade MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1
ADVANTAGESHigh flexural strength. Elongation at break > 5 mm
Very fluid. Reach the bottom of the thinnest fissures
Conversion rate > 60%
Hydrophobic High durability. No risk of detachment
Easy and fast use: etching, application then polymerization
Very resistant, less abrasion
Opaque white shade. Better contrast for a perfect surveillance application and a good survey.
INDICATIONSPits and fissures sealing
REFERENCES & DESCRIPTION
PFS-3,6 2 x 1,2 ml syringes + 10 tips. Opaque white shade
ETL 100 blue needle tips. Gauge 25MD : Class IIa certified by Tüv Rheinland (0197)
Pits and fissures sealantFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESVery resistant. Flexural strength > 100MPa
Conversion rate > 60%
Highly filles (65% weight)
Thixotropic. Remains in place without flowing
Time saving. No metallic matrix needed
Stable. Does not polymerize under the chair light
INDICATIONSRestoration of small classes III and classes V
Cavity liner in the ‘’Bond and Flow’’ technique
Fix splints after orthodontic treatments or in case of mobile teeth
Flowable nano-hybrid compositeFormulation without addition of HEMA, TEGDMA, BisGMA
4 www.elsodent.com
PUREFILL 2
PUREFILL2 Filtek Tetric Clearfil G-Aenial ElsodEnt Supreme Evoceram Majesty GC 3M ViVadEnt Kuraray
PUREFILL 2 Filtek Tetric Clearfil G-Aenial Grandio Z100 Supreme Evoceram Majesty GC Voco 3M 3M ViVadEnt Kuraray
20s 30mn 24h 48h
INDICATIONSPosterior restorations (class I, class II, MOD)
Anterior restorations (class III and class IV)
Class V cavities
Aesthetic corrections (diastema, hypoplasia, discoloration)
Nano-hybrid, antero-posterior compositeFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESLow shrinkage ~ 2 %Polymerization depth > 3mmHigh conversion rate ~ 70%Highly filled (80% weight)
Does not stick to instruments
Perfect consistency for easier use, anterior and posterior
Stable, does not polymerize under the chair light
Aesthetic. Excellent polishability
This is the first Elsodent composite developed from an innovative formulation without any addition of BisGMA, TEGDMA, HEMA, to get a low toxicity composite. Its higher biocompatibility, due to the non-hydrolysable monomers contained in the matrix of the product, leads to lower toxicity over time. It makes PureFill2 an essential product in our declaredapproach to public health.
REFERENCES & PRESENTATIONSPUR2-3-* 3g syringe. VITA shades
A1/B1 – A2 – A3 – A3,5 – B2 - C2 - Incisal - Bleach
PUR2-5* 20 x 0,25g compules. VITA shades A1/B1 - A2 - A3 - A3,5 - B2 - C2 - Incisal - Bleach
* Shade MD : Class IIa certified by Tüv Rheinland (0197)
COMPARATIVE PHYSICO-CHEMICAL TEST
* Tests conducted by G-Pharma. Volumetric shrinkage according ISO 17304. Flexural strength according to ISO 4049 - Zwick equipement. Conversion rate evaluated using a FTIR spectrometer with ATR mode. Polymerization by Elsodent curing light diam: 9mm - 600mW/cm² power at room temperature (20°C).
Conversion rate (%)*Flexural Strength (MPa)*
5www.elsodent.com
HEALBOND MPElsodEnt
HEALBOND MP
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
REFERENCES & PRESENTATIONSBMP-5 Adhesive - 5ml bottle
BMPA-5 Activator for dual-curing use - 5ml bottleMD : Class IIa certified by Tüv Rheinland (0197)
ALL-IN-ONE!
Shear bond strength* (MPa)
COMPARATIVE PHYSICO-CHEMICAL TEST
Activator for dual-mode
MULTI-PURPOSE INDICATIONS
HEALBOND MPCASE
ADHESIVE ACTIVATOR
PUREFILL 2(see p. 7)
Light-cure direct restoration Class I to V antero-posterior restorations
CORE D(see p. 14)
Self/Light-cure direct restoration (core build-up)
Core build-up Root-canal post sealing
INNOCEM(see p. 30)
Self/Light-cure indirect restoration
Indirect restorations Inlays, ceramic or composite veneers, Maryland bridges
ADVANTAGESMULTI-PURPOSE Direct & Indirect restorations
UNIVERSAL Powerfull shear bond strength on all support : tooth structures, ceramic, metal and zirconia
High shear bond strength: 13,9 MPaDesensitizing and eliminates residual bacteria
IMPORTANT NOTICE !ELSODENT formulation of INNOCEM allow HEALBOND MP to become DUAL without using an activator!
Universal self-etching light-cure adhesive system Formulation without addition of HEMA, TEGDMA, BisGMA
6 www.elsodent.com
HEALBOND MAXElsodEnt
OptibondXTRKErr
HEALBOND MAX
Adhesives Shear Bond Strenght*
INDICATIONSDIRECT RESTORATION Light-cure, self-cure, dual-cure composites
*In conjunction with INNOCEMINDIRECT RESTORATION Inlays and Onlays ceramic, metal (précious or non precious), Zircone, compositeVeneers
ADVANTAGESMULTI-PURPOSE Direct & Indirect* restorations
UNIVERSAL Strong adhesion on all surfaces: dental structures, ceramic, metal and zirconia
Compatible with all resin-cements, composites and core build-up materials, photo, auto or dual-cure
EFFICIENT Exceptionnal bonding strength when used on dentin and enamel
DURABILITY Hydrophobic once polymerized, for a long-lasting action, with no water absorption .Excellent quality of the seal over time
REFERENCES & PRESENTATIONSBMX-10 HEALBOND MAX Self-etching, Universal
bonding system (2 x 5ml bottles, primer + adhesive)
MD : Class IIa certified by Tüv Rheinland (0197)
NEW
Unique bonding solution, whatever the clinical case and the technique used
CLINICAL PROCEDURE
On the surface of enamel and dentin previously prepared, cleaned and dried and making sure to use a different disposable applicator for each component:
Apply Healbond Max Primer for 20 s. Air dry for 5 s.
Apply Healbond Max Adhesive for 15 sec. Air dry for 5 s.
Light-cure 10 s, then apply the com-posite according to the manufacturer’s instructions.
Dentin with Etching
Dentin Self-Etching
Ceramic mordançée
Metal Zirconia
COMPARATIVE PHYSICO-CHEMICAL TEST
Two-components universal self-etching light-cure adhesive system Formulation without addition of HEMA, TEGDMA, BisGMA
7www.elsodent.com
HEALBOND
OPAQ
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
INDICATIONSLight-cure composites on tooth structures
To desensitise cervical regions and free dentin areas
Dual-cure mode (core build-up), when mixed with Healbond activator
Light-cure bonding agentFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESShear bond strength ~ 13,9 MPa
Desensitizing and eliminates residual bacteria
Good wetting properties to be used on slightly moist dentin surfaces (wet-bonding technique)
REFERENCES & PRESENTATIONSB-5 HEALBOND - 5ml bottle
BA-5 HEALBOND Activator for dual-curing - 5ml bottleMD : Class IIa certified by Tüv Rheinland (0197)
Activator for dual-cure mode
INDICATIONSTo hide exposed metal surfaces after fracture of the ceramic layer on bridges and crowns.
To cover the reactive dentin in deep class III, to avoid layers of composite
Light-cure opaquerFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESHigh hiding power
Versatile in use
REFERENCES & PRESENTATIONSOPA-2 1 x 1,2ml syringe + 10 applicator tips. A3 shade
LTL 100 black needle tips. Gauge 20MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
8 www.elsodent.com
CORE D
CORE D FLOW
REFERENCES & PRESENTATIONS
CDB-25 25ml cartridge + 20 mixing tips + 20 intra-oral tips - white shade
CDD-25 25ml cartridge + 20 mixing tips + 20 intra-oral tips - dentin shade
EJ-100 100 yellow mixing tips
IJ-100 100 yellow intra-oral tips
IV-50 50 green intra-oral tipsMD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
REFERENCES & PRESENTATIONS
CDF-5 2 x 2,5ml syringes + 10 mixing tips + 10 intra-oral tips - dentine
EMP-100 100 brown mixing tip
IMP-100 100 intra-oral tipsMD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Very thixotropicNo matrix needed !
INDICATIONSCore build-up on non-vital teeth
Sealing root canal posts associated with a dual-curing bonding type HEALBOND MP
Dual-cure core build-up material Formulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESVery thixotropic. Does not flow. No matrix needed. Improves operating field vision
Hardness equivalent to dentin. No different feeling while burring
Radio-opaqueHigh flexural strength > 140 MPaHigh compressive strength ~ 330 MPaHigh conversion rate
INDICATIONSCore build-up on non-vital teeth
Sealing root canal posts associated with a dual-curing bonding type HEALBOND MP
Dual-cure core build-up fluid material Formulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESFlowable, with thin tips, to allow injection in small and narrow cavities.
Hardness equivalent to dentin. No different feeling while burring
High conversion rate = 68% (1h)
High flexural strength = 136 MPaHigh compressive strength ~ 330 MPa
9www.elsodent.com
CORE D LC
CORE D SC
CORE D LCElsodEnt
Clearfill Photocore Kuraray
CORE D LCElsodEnt
Clearfill Photocore Kuraray
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATE
RIA
LTE
MPO
RARY
BR
IDG
ES &
CRO
WN
SCI
MEN
TS &
CA
VITY
LIN
EREQ
UIP
MEN
TRE
STO
RATI
ON
ACCE
SSO
RIES
NEW
INDICATIONSCore build-up on non-vital teeth
Sealing root canal posts associated with a dual-curing bonding type HEALBOND MP
Self-cure core build-up material Formulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESThixotropic. Does not flow. No need for a matrix. Improves operating field vision
Fast setting time = 55s
Self-curing for a minimal shrinkage of the material
High flexural strength = 140 MPaHigh compressive strength ~ 330 MPa
Radio-opaque
INDICATIONSCore build-up on non-vital teeth
Light-cure core build-up material Formulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESEasy set up, even in small and narrow cavities
Thixotropic. Set-up without matrix. Time saving and optimized operating field vision
Highly charged (70% weight)
Amazing polymerization depth ~ 6 mm after 40s
High flexural strength ~ 136 MPaHigh compressive strength ~ 360 MPa
REFERENCES & PRESENTATIONSCDLCB-6 2x 3ml syringe + 10 needle tips (white)
CDLCD-6 2x 3ml syringe + 10 needle tips (dentin)
IR-100 100 pink needle tips. Gauge 18.MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
REFERENCES & PRESENTATIONS
CDSCB-25 25ml cartridge + 20 mixing tips + 20 intra-oral tips - white
CDSCD-25 25ml cartridge + 20 mixing tips + 20 intra-oral tips - dentin
CDSCB-50 50ml cartridge + 20 mixing tips + 20 intra-oral tips - white
CDSCD-50 50ml cartridge + 20 mixing tips + 20 intra-oral tips - dentin
EJ-100 100 yellow mixing tips
IJ-100 100 yellow intra-oral tips
IV-50 50 green intra-oral tipsMD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
10 www.elsodent.com
DUROC
REFERENCES & PRESENTATIONSDU-50 50ml cartridge + 10 mixing tips
EJ-100 100 yellow mixing tipsMD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Resin-based bite registration material, implant transfer caps splintingFormulation whithout addition of HEMA, TEGDMA, BisGMA
ADVANTAGESThixotropic : does not flow between teeth
Fast setting time ~ 40 s
Blue for a strong contrast
Easy to trim excess
The most rigid bite registration materials available
High flexural strength
Negligible linear shrinkage
Burn with no residue
INDICATIONSIMPLANTOLOGY Fixing together implant transfer caps before final impression
Bite registrationTo quickly and perfectly fix the two parts of a bridge infrastructure
To elaborate inlays cores in direct method
CLINICAL PROCEDURE
DUROC, implant transfer caps splinting
1 Implant transfers in place before impression.
2 Setting of Duroc is finished, giving free access to screws
3 Fitting 4 Impression made with the implant transfers
5 Replicas are in place (not screwed yet)
CLINICAL PROCEDURE
DUROC bite registration
1. & 2. Bite registration
11www.elsodent.com
11
MPa
PHOENIX ExperTemp Structur3 Protemp4 ELSODENT ultradEnt Voco 3M
PHOENIX MD
PHOENIX
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
REFERENCES & PRESENTATIONSPHMD-50-A1 50ml cartridge + 10 mixing tips - shade A1
PHMD-50-A2 50ml cartridge + 10 mixing tips - shade A2
PHMD-50-A3 50ml cartridge + 10 mixing tips - shade A3
EJ-100 100 yellow mixing tips.MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Resin for temporary bridges and crownsFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESThixotropic. does not flow and can be injected directly into the mouth around the abutment tooth
High flexural strength and slight resilience
Very thin oxygen inhibition layer
A new layer can be applied on top of an existing one up to 2 or 3 days after max.
Setting time = 2min 45s
INDICATIONSINDIRECT METHOD Temporary crowns and long temporary bridges, with a pre-impression
INDIRECT METHOD Temporary crowns directly in mouth. A temporary crown can be made in mouth within 3 min max.
* Tests carried out with a Zwick equipment, according to ISO 11405
REFERENCES & PRESENTATIONSPH-50-A1 50ml cartridge + 10 mixing tips - shade A1
PH-50-A2 50ml cartridge + 10 mixing tips - shade A2
PH-50-A3 50ml cartridge + 10 mixing tips - shade A3
EB-100 100 blue mixing tips.MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Resin for temporary bridges and crownsFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESHigh flexural strength > 100 MPaExtremely reduced inhibition oxygen layer: the surface of the cured material is almost dry
Easy and fast to use
Aesthetic
INDICATIONSTemporary crowns
Small temporary bridges, with a pre-impression (indirect method)
Flexural strength*
12 www.elsodent.com
201006366_201905
G-PHARMA35, avenue du Gros ChêneB.P. 10279 HERBLAY95617 CERGY-PONTOISE Cedex [email protected]
TopBaseDate de révision : 02-2019
Depuis 12-2017
4a 4b
1
6
7
9
2a 2b
3
5
8
2. Rendre la surface légèrement rugueuse, avec du papier de verre, une fraise ou sabler l’intrados de la prothèse avec de l’oxyde d’alumine. [cf 1]
3. Nettoyer la surface avec de l’alcool puis sécher parfaitement avec un air sec exempt d’eau et d’huile.
Rebasage1. Positionner la plaque sur l’intrados de la prothèse en prenant soin de bien la centrer.
[cf 2a - 2b]2. A l'aide d'un pulseur à air chaud (température réglée à 250 °C) ou d’un sèche-
cheveux, chauffer la plaque en commençant par le centre, puis continuer sur les côtés afin de répartir la chaleur équitablement. [cf 3]
3. Une fois la plaque ramollie uniformément, elle devient transparente et adhère à l'intrados de la prothèse. [cf 4a - 4b]
4. Si nécessaire, avec vos gants légèrement humides, plaquer bien le produit sur l’intrados pour obtenir un meilleur contact et une excellente adhésion, tout en évitant d’emprisonner des bulles d’air. [cf 5]
5. Eliminer déjà, les excès de matériau sur les bords de la prothèse, avec les doigts bien humides. [cf 6-7]
6. Plonger le produit dans un bol d’eau chaude à 70°c [cf 8] avant la mise en bouche pour éviter que la plaque ne colle à la muqueuse en cas d’hyposialie et pour améliorer l’enregistrement des détails de la muqueuse.
7. Une fois la prothèse, en bouche, demander au patient de serrer les dents pendant 2 minutes, afin que la plaque enregistre parfaitement tous les détails de la surface de la muqueuse. [cf 9]
8. Retirer de la bouche. Si une modification est nécessaire, il est possible de réchauffer TopBase à l’infini, et de réinsérer la prothèse en bouche, sans oublier au préalable de la retremper dans le bol d’eau chaude 15 secondes.
9. Eliminer les excès et polir avec une cupule ou un disque en caoutchouc. On peut aussi rechauffer les bords pour arrondir le produit.
ConseilLe contact et donc la tenue en bouche sera améliorée si la prothèse est préalablement mouillée avant la remise en bouche. Toujours tremper la prothèse dans le bol d’eau chaude avant chaque mise en bouche.Temps de priseLe temps de prise total jusqu’à complète réticulation est d’environ 3 minutes maximum.Stockage et durée de vieNe pas exposer aux rayons du soleil directs ou à des sources de chaleur. Conserver à une température inférieure ou égale à 32°C. Dans ces conditions, la durée de vie des plaques TopBase est de 36 mois.Présentation & référencesTPU - Kit de 2 plaques maxillaires TPD - Kit de 2 plaques mandibulairesTPK - Kit de 1 plaque maxillaire & 1 plaque mandibulaire TPCLU - Kit clinique de 10 plaques maxillaires TPCLD - Kit clinique de 10 plaques mandibulaires
Note importanteNe pas jeter la boite et la notice avant l’utilisation complète du produit. Une humidité élevée pourrait endommager les emballages comportant les informations importantes et légales. Un stockage à une température trop élevée peut faire vieillir prématurément le produit. Délégation de responsabilitéCe produit a été développé en vue d’une utilisation dans le domaine dentaire seulement et doit être mis en œuvre selon le mode d’emploi. Les dommages pouvant résulter du non-respect de ces prescriptions ou d’une utilisation à d’autres fins que celles indiquées n’engagent pas la responsabilité du fabricant. L’utilisateur est tenu de vérifier sous sa propre responsabilité l’appropriation du produit à l’utilisation prévue, et ce d’autant plus si celle-ci n’est pas citée dans le mode d’emploi.
TOPBASE
REFERENCES & PRESENTATIONS
TPU TOPBASE Kit of 2 maxillary plates
TPD TOPBASE Kit of 2 mandibular plates
TPCLU TOPBASE Clinical kit of 10 maxillary plates
TPCLD TOPBASE Clinical kit of 10 mandibular plates
TPK TOPBASE Set 1 maxillary plate + 1 mandibular plates
DM class IIa
Thermoplastic plate to reline denturesBIOCOMPATIBLE, BisGMA, TEGDMA, HEMA-FREE
ADVANTAGESVery easy and fast use
No mixing of products
A perfect relining in 10 to 15 minutes only
With a good air dryer, or a heat air gun
Sticks directly and strongly to any type of resins used for dentures
Very economicalAesthetic
Accurate recording of details of the mucosa
Can be re-shaped anytime by re-heating it as many time as needed
Biocompatible, no addition of BisGMA, TEGDMA, HEMA. No toxicity
INDICATIONSSemi-definitive, hard relining of dentures
Demo video
CLINICAL PROCEDURE
1. Clean the intrados of the prosthesis, Make the surface slightly rough, with sandpaper, a bur then rinse with alcohol and dry thoroughly.
2. Center the plate on the intrados of the prosthesis [cf 2a - 2b]3. Heat the plate from the centre to the sides to distribute the
heat evenly. [cf 3]4. Once the plate has softened uniformly, it’s translucent and
adheres directly to the intrados of the prosthesis. [cf 4a - 4b]5. Push the soften plate into the intrados (wet gloves) [cf 5]6. 7. Start immedialtely to remove material in excess, on the
edges of the prosthesis with your fingers wets. [cf 6-7].8. Immerse in hot water (70°C) [cf 8], before putting it in mouth,
to avoid any risk for the plate to sick to the mucosa, in case of hyposalia.
9. Once in mouth, ask the patient to bite firmly for 2 minutes, in order to accurately register all the details of the surface of the mucosa. [cf 9]. Remove from the mouth then eliminate excesses and polish with rubber cup or disc.
13www.elsodent.com
SEAL TEMP & SEAL TEMP S
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CAC
CESS
ORI
ESCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
Temporary resin-based cementsFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESPerio-friendlyThanks to the smooth cement texture, the gum completely heals within 2 to 3 days
Any procedure (impression, etc) can be performed withtout haemostatic problems
Suitable use on vital teeth
Time saving The cement sticks to the intrados of the temporary crowns: The prepared teeth always remain clean
Before putting the temporary crown back on the tooth:
SEAL TEMP : just apply a new layer of cement. If a supra-occlusion occurs, just trim the external surface of the temporary crown.SEAL TEMP S : remove the old layer of cement with tweezers, prior to applying a new one
2 complementary cements for all clinical cases
REFERENCES & PRESENTATION
ST-25 SEAL TEMP 2x 12,5g syringes (base + catalyst)
STD-16 SEAL TEMP 2x 5ml dual syringes + 20 mixing tips
STD-8 SEAL TEMP 1x 5ml dual syringe + 10 mixing tips
STS-25 SEAL TEMP S 2x12,5g syringes (base + catalyst).)
STDS-16 SEAL TEMP S 2x 5ml dual syringes + 20 mixing tips
STDS-8 SEAL TEMP S 1x 5ml dual syringes + 10 mixing tips
EM-100 100 brown mixing tips.MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
INDICATIONSSEAL TEMP - Strong retention strengthTemporary bridges and crowns on low abutment teeth.
Long-term temporary crowns (2-3 months).
Definitive cementation of crowns on implant, except prosthetics elements in Zirconia
SEAL TEMP S - Classic retention strengthTemporary bridges and crowns on normal abutment teeth and implants
Temporary cementation of definitive veneers to valid aesthetic
14 www.elsodent.com
INNOCEM Breeze Relix Panavia Cement SmartCem2 G-Cem MaxCem PEntron Unicem Kuraray Resin SE dEntsPly Gc Elite 3M cybErtEch KErr
20 s 6 mn 30 mn
INNOCEM Relyx Panavia Breeze Cement MaxCem G-Cem Unicem Kuraray PEntron Resin SE Elite Gc 3M cybErtEch KErr
INNOCEM Relyx Panavia SmartCem MaxCem Breeze G-Cem Unicem Kuraray 2 Elite PEntron Cement 3M dEntsPly KErr GC
Dentine Métal Zircone Céramique
INNOCEM
REFERENCES & PRESENTATIONSIC-10 -TA2 5ml syringe + 10 mixing tips + 10 regular intra-
oral tips. Translucent A2 shade
IC-10-OA2 5ml syringe + 10 mixing tips + 10 regular intraoral tips. Opaque A2 shade
IC-10-OA3 5ml syringe + 10 mixing tips + 10 regular intraoral tips. Opaque A3 shade
MD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Conversion rate*
Flexural strength*
Shear bond strength*
* Tests conducted by G-Pharma. Flexural Strength according to ISO 4049 and carried out with a Zwick equipment. Conversion rate using FTIR spectrometer (ATR). Shear bond strength according to ISO 11405 and carried out with a Zwick equipment
TESTS RESULTS & COMPARISON
Excellent adhesion to Etched ceramic: 23,9 MPa Dentin: 14,10 MPaZirconia: 19,3 MPa Metal: 23,81 MPa
INDICATIONSMetal, composite, etched (or silanisated ceramic) inlays, onlays, crowns and bridges
In conjunction with HEALBOND MP Maryland bridges of 2 to 3 elements Etched (or silanisated) ceramic veneers. Root canal posts (metallic or fiber posts)
Self-adhesive universal permanent resin cementFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESStrong adhesion to dentin, metal, Zirconia, composite and etched (or silanated) ceramic
Unsurpassed conversion rate = 58,40% (30 min.)
Résistance à la flexion excellente = 90 MPa
Fast and easy to use - No pre-treatment required in most cases After 5 seconds of polymerisation, the excesses remain slightly rubbery to be easily removed
Strong hiding power (opaque versions). Perfect for cementation of aesthetic prosthetics elements on implant abutments, or on metallic elements such as inlay core and amalgams
Slight hydrophilia before polymerization for collagen fibers and phosphate ions complexation (vital teeth) and hydrophobia for a long-term and stable adhesion
IMPORTANT NOTICE !INNOCEM formula allows HEALBOND MP to become DUAL without addition of an activator.
15www.elsodent.com
NOTRE DAM
PROREZ
IMPR
ESSI
ON
IMPL
ANTO
LOG
YEN
DO
DO
NTI
CCO
RE B
UIL
D-U
P M
ATER
IAL
TEM
PORA
RY
BRID
GES
& C
ROW
NS
CIM
ENTS
&
CAVI
TY L
INER
EQU
IPM
ENT
REST
ORA
TIO
NAC
CESS
ORI
ES
REFERENCES & PRESENTATIONSPRZ-16 2 x 5ml dual syringes + 20 mixing tips + 20 intra-
oral tips
EMP-100 100 brown mixing tip
IMP-100 100 intra-oral tipsMD : Class IIa certified by Tüv Rheinland (0197), excl. tips, Class 1.
Dual-cure composite for temporary fillingFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESFast setting : 45 sec (self-curing mode)
Easy to place, even in small or narrow cavities, with the dual syringe and its intra-oral tip
ThixotropicWaterproofEasy to remove with a probe or a curette
Aesthetic A3 shade
Fluoride release
INDICATIONS Temporary filling for inlay and onlay preparations
Temporary filling for implant screw holes
Temporary filling for other cavities to be protected (after endodontic treatments...)
INDICATIONSRestorative dentistry To hold Teflon® film in place when luting aesthetic venners, or making a class II composite involving the contact point
Prosthodontic To fill up undercuts before impression, to avoid tearing off the material
Endodontic To insure a waterproof joint of the rubber dam around a tooth during an endodontic session.To build temporary tooth walls during endodontic sessions, to hold the irrigating liquid in place
Bleaching Protection of soft tissues during bleaching process
Multipurpose light-cure liquid damFormulation without addition of HEMA, TEGDMA, BisGMA
ADVANTAGESLow exothermic reaction to avoid harmful reaction of the mucosa
Excellent thixotropy for an easy setting
Versatile multi-purpose
Blue for a good contrast
REFERENCES & PRESENTATIONSND- 4 2 x 1,2ml syringes + 10 tipss
LTL 100 black needle tips. Gauge 20Dispositif médical de classe IIa certifié par Tüv Rheinland (0197) hors embouts, classe I
LABORATOIRE ELSODENT 35 av du Gros Chêne | BP50072 HERBLAY | 95612 CERGY-PONTOISE CEDEX Tél : +33 1 30 37 75 75 | Fax : +33 1 34 40 07 04 | Email : [email protected]
INFO & CONTACT
+33 (0) 1 30 37 75 75 [email protected]
www.elsodent.com
ISO
134
85
CTBIO-02 EN JAN-20
Den
tal
med
ical
dev
ices
for
den
tal
prof
essi
onna
ls o
nly,
not
ref
unde
d by
the
Hea
lth I
nsur
ance
. Ca
refu
lly r
ead
the
intr
uctio
ns o
n th
e pr
oduc
t pac
kagi
ng a
nd n
otic
es b
efor
e us
e. O
ur p
rodu
cts
are
man
ufac
ture
d by
G-P
harm
a ce
rtifi
ed b
y Tü
v Rh
einl
and
acco
rdin
g to
the
ISO
134
85 s
tand
ard.