2 Initial Setup Contents 4 Installation Diagrams 6 Wiring Diagrams 13 Enrolling Door Controls Wi-Pin & Prox Wi-Pin Wi-Prox Other products from GSD Installation & User Manual V2.05 Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght, Dublin 24, Ireland, Phone: +353 (1) 524 2691, Email: [email protected] www.globalsecurity.ie YOUR SECURITY IS OUR PRIORITY

Upload: others

Post on 06-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

2Initial Setup

Contents

4Installation Diagrams

6Wiring Diagrams

13Enrolling Door Controls

Wi-Pin & ProxWi-PinWi-Prox

Other products from GSD

Installation & User Manual V2.05Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght,

Dublin 24, Ireland, Phone: +353 (1) 524 2691, Email: [email protected]

www.globalsecurity.ie

YOUR SECURITY IS OUR PRIORITY

Page 2: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

2 Initial Setup

Power Supply 12V DCCurrent consumption 70mACurrent consumption with load (max) 100mARelay Contact Rating 5 Amps /240V acOperating Temperature -20 C to +60 CMoisture Resistance IP 67Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm - Surface Mount W. 87mm D. 35mm H. 119mmNumber of Users 20000

Technical Specs

Initial InstallationThe Door Control should be Factory Defaulted after installation. This will restore alldefault settings to the Door Control and will unenrol it from any existing GSDController.The Door Control will then start to scan and enrol on a GSD controller.

Refer to the section ‘Enrolling Door Controls’ for instructions on how to configurethe GSD Windows Software.

Restoring Factory Settings - Wi-Pin&Prox, Wi-Pin

Code Description 55 Restore Factory Default Settings

Example: X key thenEngineer

Code + +Code = 55

Note: The Door Control can not be defaulted while enrolled onto a GSD networkcontroller. The Door Control must first be disabled using the GSD windowssoftware.

If the Door Control is enrolled onto the GSD Network Controller then theDefault Engineer code will be set by the GSD windows Software.

If Engineer Code is lost, Ensure the Door Control is disabled using the GSDwindows software , then remove the Security Caps (see page 5) andhold down the X key during power-up and enter the default EngineerCode ‘6666’ immediately.This will restore the factory settings.

3 Initial Setup

Restoring Factory Settings - Wi-Prox

Step Description

1 Present Programming Card 2 Times

2 Present Any Card Once

ProgrammingCard x 2

AnyCardx 1

Adding a Programming Card

Note: Add a programming card to the Wi-Prox Door Control. The DoorControl must be disabled first if it has been enrolled onto a GSD NetworkController.Follow the below method to add a programming card to the Door Control.

Adding a Programming Card

AnyCard x 2

Step Description

1 Remove security caps and power down unit.

Power up unit and Present Any Card 2 times 2 immediately. This card is now the Programming

Card for the unit. Refit security caps

Factory Default PIN codesThe following PIN codes are the Factory Default Settings:

- The Default Engineer code is ‘6666’

- User PIN ‘1111’

Note: The User PIN ’1111’ is deactivated when the Door Control is enrolledonto a GSD Network Controller.

Page 3: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

4 Installation Diagrams

When Surface Mounting the Door Controla Surface Mount Collar is required.

- Fix Surface Mount Collar towall, ensure arrow is

pointing upwards

After fixing Surface Mount Collar to wall(as above) and wiring is complete as perwiring diagrams on pages 6-11, the DoorControl may then be screwed toSurface Mount Collar usingsecurity screws provided.Both Security Caps arethen clipped onto the DoorControl.

To attach Security Caps: Simplyalign the tabs into holes and pushon until click is heard.

Surface Mounting

Security Caps

5Installation Diagrams

To release Security Caps push ascrewdriver into slots on the sideand pull forward.

Door Control is mounted to electrical pattress box using securityscrews provided. Both Security Caps arethen clipped onto Door Control.

Flush Mounting

To attach Security Caps: Simplyalign the tabs into holes and pushon until click is heard.

Page 4: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

6 Wiring Diagrams

Slave Reader connections

7Wiring Diagrams

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

Standard connections

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

12V

0V

ExternalReader

Data0/Data

Data1/Clock

Yellow & White

Red & Brown

DoorExit Button

DoorContact

0V

0V

DoorExit Button

DoorContact

0V

0V

Select the Slave Reader optionfrom the drop-down listfor IP3 on the PC applicationfor this Door Control.

12V

16VVaristor

DoorMagLock

Break GlassUnit

12V

16VVaristor

DoorMagLock

Break GlassUnit

0V0V

Page 5: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

8 Wiring Diagrams

Fire Alarm Override

9Wiring Diagrams

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

Alarm Panel connections

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

DoorExit Button

DoorContact

0V

0V

DoorExit Button

0V

DoorContact

0V

Arm Alarm Input

Arm Output (N/O)

Alarm PanelAlarm Panel Notes:Common OV from theIntruder Alarm Paneland the OV from theDoor Control to avoidany ground loop issues.

Only the Manager Usercan activate/deactivatethe Alarm Panel. Whenthe Alarm Panel isactivated all other usersare locked out.

Select the Panel Alarm optionfrom the drop-down listfor IP3 on the PC applicationfor this Door Control.

Fire AlarmPanel

FireAlarm Panel Notes:Common OV from theFire Alarm Paneland the OV from theDoor Control to avoidany ground loop issues.

When the fire alarmis activated (0V removedfrom IP3) the door willbe opened.

Select the Fire Alarm Override optionfrom the drop-down listfor IP3 on the PC applicationfor this Door Control.

0V12V

16VVaristor

DoorMagLock

Break GlassUnit

12V

16VVaristor

DoorMagLock

Break GlassUnit

0V0V

Page 6: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

10 Wiring Diagrams

Sounder & Follow Relay

11Wiring Diagrams

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

Interlock connections

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

A BTA

MP

TAM

P

Interlock OP toInterlock IP on2nd Door

Interlock IP fromInterlock OPon 2nd Door

DoorContact

0V

0V

DoorExit Button

Select the Interlock Input optionfrom the drop-down listfor IP3 on the PC applicationfor this Door Control.

FollowRelay

- Fire Alarm Override- Lock Door- Card and Pin- Card or Pin

DoorExit Button

0V

DoorContact

0V

12V

Sounder

The Follow Relay option is enabledon OP1 when any of the followingoptions are selected on IP3 on thePC application for a Door Control:

- Fire Alarm Override- Lock Door- Card and Pin- Card or Pin

12V

16VVaristor

DoorMagLock

Break GlassUnit

12V

16VVaristor

DoorMagLock

Break GlassUnit

0V0V

Page 7: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

12 Wiring Diagrams 13Enrolling Door Controls

Wired 485 connections

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in thediagram are connected toOV of the Door Control.

0V

12V0VNOCOMNC

12 - 24 VAC

12 - 24 VAC

16VVaristor

12V0VNOCOMNC

IP3IP2IP1

OP1OP2

12V LinearPower supply

DoorContact

0V

0V

DoorExit Button

AB

0V

Note : Used ONLY forWired 485 Network Connections.

12V

16VVaristor

DoorMagLock

Break GlassUnit

Volt FreeTamper Contacts1 and 2

AB

0V

Note : Used ONLY forWired 485 Network Connections.

A BTA

MP

TAM

P

Adding Door Controls Overview

Step Description

1 Install and Wire each Door Control

2 Default each Door Control

3 On PC application - Doors TabClick on Add New Door to add a new door to the system

4 Enrolling On a New System Install:On PC application - Controller Tab - Wireless NetworkClick on Create New Network.Continue with Step 5

5 Enrolling On an Existing System:On PC application - Controller Tab - Wireless NetworkClick Allow Doors to Join.

6 Each new Door Control will beep the next available address on thesystem

7 Press a key or present a Fob to assign this address to any DoorControl. Continue with steps 6 & 7 until all new Door Controls areassigned an address on the system.

8 After all Door Controls are assigned an address:On PC application - Controller Tab - Wireless NetworkClick on Secure Network.This secures the wireless network.

9 On PC application - Doors Tab,Configure each Door Control with desired settings.

0V

Page 8: Initial Setup 2 Installation Diagrams 4 Wiring Diagrams 6 ...globalsecurity.ie/userfiles/files/Manual GSDn-WPP V2.05 WEB.pdf · Installation Diagrams 4 Wiring Diagrams 6 Enrolling

15

Assigning a Door Address on Wireless Network

Step Description

1 On the Controller screen: Click ‘Allow Doors to Join this Controller’

All Door Controls that don’t have an address start to beep out the next available address. The Keys will also illuminate to indicate the address. e.g. Keys 1 & 5 will be ON for address number 15.

2 Hit any key on the ‘beeping’ Door Control to assign this address. Present a Card on the ‘beeping’ Proximity unit to assign this address.

When a Door Control is assigned an address, all unassigned Door Controls will start to beep the next available address.

3 When all doors are assigned: Click ‘Secure Network’

Assigning a Door Address on a Wired 485 Network

Step Description

1 Right Click on the Controller Icon & select ‘Manually Assign Addresses’

Follow Step 2 above to complete the process.

Enrolling Door Controls14 Enrolling Door Controls

Adding Door Controls

Step Description

1 Click the Doors Icon on the left hand toolbar

2 Click ‘Add New Door’

3 The Door is added to the Controller.

4 Configure the required Door settings : Door Timers, Alarm Options,Door Options, Timed Actions, Inputs & Outputs.

5 Click ‘Save’ to transmit the changes to the GSD Controller.

1

2

5