infrared thermography (irt) -...

7
1 Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process S. Miotello 1 , C. Stelletta 2 , A. Simonetto 1 , R. Cecchinato 3 , F. Tagliapietra 1 and L. Bailoni 1 1 Animal Science Department, University of Padova, Italy 2 Veterinary Clinical Science, University of Padova, Italy 3 KWS Italia Spa, Italy Session 30 Abstract 4692 Infrared thermography (IRT) Innovative technique that detects infrared radiation and generates images based on the amount of heat emitted by any subject. It is a non-invasive technique, relatively cheap, rapid and easily obtained APPLICATIONS: Surveillance in security and defence Night vision Condition monitoring Volcanology Process control Chemical imaging Nondestructive testing Medical imaging Infrared Mammography Research Veterinary medicine

Upload: doandan

Post on 01-Feb-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

1

Infrared thermography as a suitable technique to evaluate the quality of corn

silage after the fermentation processS. Miotello1, C. Stelletta2, A. Simonetto1, R. Cecchinato3, F. Tagliapietra1 and L. Bailoni1

1Animal Science Department, University of Padova, Italy2Veterinary Clinical Science, University of Padova, Italy

3KWS Italia Spa, Italy

Session 30 Abstract 4692

Infrared thermography (IRT)Innovative technique that detects infrared radiation and generatesimages based on the amount of heat emitted by any subject.

It is a non-invasive technique, relatively cheap, rapid and easilyobtained

APPLICATIONS:� Surveillance in security and defence� Night vision� Condition monitoring� Volcanology� Process control� Chemical imaging� Nondestructive testing� Medical imaging� Infrared Mammography� Research

� Veterinary medicine

Page 2: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

2

18.4

39.7 °C

20

25

30

35

FLIR Systems

18.4

39.7 °C

20

25

30

35

FLIR Systems

18.4

39.7 °C

20

25

30

35

FLIR Systems

Ar1:max 34.8

20.0

35.0 °C

22

24

26

28

30

32

34

FL IR Sy stems

POSSIBLE USESPOSSIBLE USES

CENSUSCENSUS

CONTROLCONTROL

VITALITYVITALITY

QUALITYQUALITY

Few researches report its utilization in feed evaluation

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Aim

To verify the suitability of the Infrared Thermography to assess the quality of the corn silage after the fermentation process

Page 3: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

3

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Material and Methods/1Six different hybrids of corn were ensiled into mini-silos (3 x 2.5 x 6.2 m)

During feedout:�Bags buried were recovered andanalyzed for chemical composition (grosscomposition, fiber fraction, pH value, ammonianitrogen, buffer capacity, VFA, starch, sugars and

alcohols; AOAC, 2000) and DM and NDFdegradability (DAISYII)

� Nutritional value of different silagewere assessed (TDN, ENL, UFC, UFL; NRC,2001)

�IRT measurements of each silo weretaken

D1= 93 d D2= 100 dD3= 114 d

Use of the buried bag technique (Woolford, 1984) at three different depthes (D1�D3)

DD33DD22DD11

+

+

+

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Material and Methods/2 � Hand-held portable infrared

camera (ThermaCam P25, FlirSystem)

� Calibrated to environmentaltemperature, humidity andabsorptive condition

� Distance was fixed at 4 m

� The images were elaborated bya specific software (ThermaCamResearcher basic 2.08)

� Data were reported as averagetemperature

Page 4: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

4

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

8.6°C

16.5°C

10

12

14

16

8.6°C

16.5°C

10

12

14

16

8.6°C

16.5°C

10

12

14

16

8.6°C

16.5°C

10

12

14

16

8.6°C

16.5°C

10

12

14

16

8.6°C

16.5°C

10

12

14

16

Different color palettes available for highlight a temperature gradient

Material and Methods/3

Before silage removing

After silage removing

Passage ofMixer-wagon

Material and Methods/4

All data were subjected to statistical analysis

Page 5: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

5

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Results/1

ANOVA of hybrid and depth effects on post removing silage temperature (R2=0.98)

Effect D.F. TemperatureHybrid (H) 5 ***Depth (D) 2 ***H x D 10 ***Error 36 0.52

***=P<0.001

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Results/2

Effect of hybrids x depth interaction on temperature post removing silage

0

5

10

15

20

25

A B C D E F

D1D2D3

Hybrids

°C

0

5

10

15

20

25

A B C D E F

D1D2D3

Hybrids

°C

Page 6: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

6

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Results/3Correlations between T values and chemicalcharacteristics of the silage

DM % y = -0.4296x + 37.201

R2 = 0.2383

20

25

30

35

40

0 5 10 15 20 25

NDF % y = 0.5138x + 41.461

R2 = 0.2883

35

40

45

50

55

60

0 5 10 15 20 25

°C

°C

Lactic acid %VFAy = -1.153x + 77.978

R2 = 0.228

40

50

60

70

80

0 5 10 15 20 25

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Results/4Correlations between T values and fermentation products and nutritional

characteristics of the silage

DMd % y = -0.3957x + 73.19

R2 = 0.1833

55

60

65

70

75

80

0 5 10 15 20 25

°C

°C

Page 7: Infrared thermography (IRT) - EAAPold.eaap.org/Previous_Annual_Meetings/2009Barcelona/Papers/30... · 3 Miotello et al. , Infrared thermography as a suitable technique to evaluate

7

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

Conclusions

�These preliminary results show that IRT can be useful to evaluate thequality of silage after the fermentation process because goodcorrelations were found between temperature and some chemical andnutritional characteristics of silage

�Great potential of IRT in forage evaluation (i.e. evaluation of silage qualitywithout chemical analyses; monitoring the trend of fermentation processes; identifyarea with anomalous fermentations)

�Image elaboration could supply other information (i.e. temperature

classes distribution; hot/cold spots; thermal variability) to better evaluate thequality of forages

Miotello et al., Infrared thermography as a suitable technique to evaluate the quality of corn silage after the fermentation process

[email protected]