industrial-switch profi line modular microsens gmbh & co. kg

24
Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Upload: adam-parsons

Post on 17-Dec-2015

228 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial-SwitchProfi Line Modular

MICROSENS GmbH & Co. KG

Page 2: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Application Levels

Fiber to the Office Industrial Ethernet

Modular Access Platform

CWDM / DWDM Platform

Page 3: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Enviroment:

Harsh conditions

High level of EMI

Limited access

Long distances betwen locations

Telecomunication system:

Integration of different services

Redundancy, efficiency, reliability

Cost effective and easy upgrade

Future-proof concept

Advanced management

General requirements:

Industrial Ethernet

Page 4: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Redundant high performance Gigabit Ring for

Fault Tolerant Networks

Compliance to: IEC 61850-3 2002, IEEE 1613:2003, IEC 60870-2-2:1

Extended Temperature Range -40 °C to +75 °C

1x 10/100/1000Base-T

7x 10/100Base-TX

3 SFP uplinks

24 VDC input, redundant

Optional PoE IEEE802.3af (48 VDC)

10 Port Gigabit Ethernet Ring-Switch

Page 5: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Enable Ring functionality on all switches

Choose the same Ring no.

Define all swtiches as slaves

Choose Master

Physically close the Ring

Fault tolerant Ethernet Ring – how does it work?

Page 6: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Redundant ring coupling

Page 7: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Ring, Dual Ring, Redundat Ring Coupling

IGMP Snooping

IEEE 802.1p QoS

Authentication with IEEE 802.1x

VLAN with IEEE 802.1Q

CDP, LLDP

Port Access Control

Rapid Spanning Tree Telnet and web based management DHCP option 82

10 Port Gigabit Ethernet Ring-Switch

Page 8: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Application specific standards

Power Stations

IEC 61000-6-5, IEEE 1613, IEC 61850-3Immunity for power station and substation environments

Railways

EN 50121-4, EN 50125-3Emission and immunity of the signaling and telecommunications apparatus

Chemical/Mining Industry

EN 50020Electrical apparatus for potentially explosive atmospheres - Intrinsic safety "i"

Page 9: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial solutions

Compliance to IEC 61850 -3, IEEE 1613, EN50121-4:2006, EN50125-3:2003

Extreme compact chassis, IP20

High efficiency

Integrated over voltage protection

Snap-on mounting on 35 mm hat-rails

Parallel operation of up to 5 power supplies

24VDC and 48VDC versions

Optional DC/DC converter

DIN Rail Industrial Power Supplies

Page 10: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Physical protection of ring structures in case of power loss

Protection against failure of many devices

Seamless installation

Relaible operation

Fiber GUARD

Industrial solutions

Page 11: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Fiber GUARD

Industrial solutions

Normal operation Failure

Page 12: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Why New System?

New long-living hardware-platform

- efficient and powerful due to newest technology

- open by using standard CPU

Open software architecture

- flexible and future proof by using Linux OS

- dynamic and expandable by central data-model

Page 13: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular (basic module)

Hardware Features

Expansion Portfuture use

Serial PortTerminal

Combo Ports (4x)10/100/1000 Base-TXEnergy Efficient EthernetPoE+ (max. 30 W)Fiber Uplink

local Ports (8x)10/100/1000 Base-TXEnergy Efficient EthernetPoE/PoE+ (max. 30 W, PSE)

LED Display Switch/Port/

PoE Status/ Ring

Reset Button Reset/Factory Defaut

2xPower 24..57 VDC

redundant

local Port10/100/1000 Base-TX

Energy Efficient EthernetPoE/PoE+ (max. 30 W, PD)

SD-Card Slot access-protected

Expansion-Backbone

Page 14: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular (basic module)

Hardware Features

Alarm-Contact Ports (2) in

Din-Railunlock

Alarm-Contact Ports (2) out

Combo Uplink Ports SFP/fixed/RJ-45 (PD)

Mounting-Ports forexpansion-modules

Page 15: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular (expansion module)

4-Port expansion module

Din-Rail mounting

Combo Uplink Ports SFP/fixed/RJ-45 (PD)

Combo Ports (2x)10/100/1000 Base-TXEnergy Efficient EthernetPoE+ (max. 30 W)Fiber Uplink

local Ports (4x)10/100/1000 Base-TXEnergy Efficient EthernetPoE/PoE+ (max. 30 W, PSE)

Expansion-Backbone

Page 16: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular (expansion module)

8-Port expansion module

Din-Rail mounting

Combo Uplink Ports SFP/fixed/RJ-45 (PD)

Combo Ports (4x)10/100/1000 Base-TXEnergy Efficient EthernetPoE+ (max. 30 W)Fiber Uplink

local Ports (8x)10/100/1000 Base-TXEnergy Efficient EthernetPoE/PoE+ (max. 30 W, PSE)

Expansion-Backbone

Page 17: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular

Hardware-Platform

- Newest switch-Technology, Energy Efficient Ethernet

- Power-over-Ethernet+ (802.3at) on all copper-ports (max. 200W)

- microSD-Card for Firmware and configuration

- Solid metal housing, clear port layout

- DIN-Rail mounting

- Temp. Range -40..+70°C

- Red. power-supply

- Additional expansion modules (ports, services etc.) available

Page 18: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Profi Line Modular

Certificates

- EN 60950-1

- CE Marking

- EN 50121-4:2006 (railway applications - electromagnetic compatibility)

- EN 50125-3:2003 (railway applications - environmental conditions)

- IEC 61850-3 (electrical substation automation)

- IEEE 1613 (electric power substations)

- Other (e.g. ABB etc.)

Page 19: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Firmware Profi Line Modular

open architecture

Profi Line Modular

Page 20: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

GVRP

Traffic-Shaping

DHCP-Option 82

Ring-Protocols

MICROSENS

MRP

802.1X Port-based Access Control(MAC and IP)

Routing-Protocols (OSPF , RIP)

Profi Line modular - Firmware

High Performance-CPU 800 MHz ARM

Linux OS Standard Kernel

Switch Features IPv4/IPv6 Dual Stack

NMP Professional/Server

Webmanager (HTTP/HTTPS)

Telnet/SSH/CLI

SNMP v1/v2c/v3

Rapid Spanning Tree

LLDP/CDP/LLDP-MED

NTP

PTP (IEEE 1588)

Page 21: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Users of Industrial Solutions

Production Sensor and actor communication (robots, machines)

stable production environment

Security Video surveillance (CCTV)

Access control

Railway / transport Signalization, passenger information, ticketing

Plant data collection

Energy Measurement / Controlling / Regulation

Automation / Telecontrol

Defence Mobile control stations, monitoring systems

Mining Production, Control

21

Page 22: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial Ethernet

Railway certificate EN 50121-4:2006 (EMC, electromagnetic noise immunity), EN 50125-3:2003 (Temperature, climate- vibration- and schockresistance

Installation close to the tracks (until 1m)

Applications railway:

Video surveillance of railway stations

Control of passenger information systems

Connection of ticket machines and weather stations

Barrier control

Track control network; Power management

22

Certification for Railway Applications

Page 23: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Industrial Ethernet

Utility certification: European EN 61850-3and US-standard IEEE 1613 „Power Substations“

Highest requirements for noise immunity and system stability

Utilities, power plant operator, windfarms

Applications:

IP based automation and telecontrol

Measurement / control / regulations

Video surveillance (IP)

23

Certification for Power Substations

Page 24: Industrial-Switch Profi Line Modular MICROSENS GmbH & Co. KG

Thank you!

MICROSENS GmbH & Co. KG