industrail trainining in telecommunication
DESCRIPTION
This slide contains all the related information regarding Telecom and 3g BTS technologiesTRANSCRIPT
Presented BySUMIT SINGH
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Site Analyser 2500 EX
FRONT VIEW OF SITE ANALYSER
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Site Analyser 2500 EX
ON / OFF
NIGHT
VISION
LED
Sel
ecti
on
Bu
tto
ns
Function buttonsNumeric Keypad
Arr
ow
key
bu
tto
ns
FRONT VIEW OF SITE ANALYSER
CHRGPWR
CHRG
ON / OFF
NIGHT
VISION
LED
Use to select the
particular functions
adjacent to it.
SELECTION BUTTONS
Sel
ecti
on
Bu
tto
ns
Config : To select the freq. range in measure
match mode and Distance range in
fault location mode.
Mode : Use to select the mode.
Calibration : It use to set the internal loss
of site analyzer to zero.
Marker : Use to mark the exact position
on the graph.
FUNCTION BUTTONS
7 8 9
4
1
0
5
2
_
6
3
-/+ES
CEN
TR
It is used to insert the values during
the selection of frequency range and
distance range.
NUMERIC KEYPED
Up
Down
RightLeft
Using these four arrow keys we can shift the marker to
the desired position
( Up key for max. VSWR, Down key for min. VSWR,
Left/Right key to move the marker along with the trace)
Also we use Left/Right key during the selection of
freq. range & dist. Range.
ARROW KEY BUTTONS
DO NOT APPLY EXTERNAL
PWR TO IT
Charging Port
RS
232 P
ort
Printer Port
RF Antenna Port ½’’ F
TOP VIEW OF SITE ANALYSER
To measure the VSWR.
To measure the return loss.
To measure the cable loss.
To measure the insertion loss.
To measure the forward power.
To measure the reflected power.
USES
It gives graphical representation of the measurement.
It can measure the VSWR with respect to frequency.(780
MHz – 2500 MHz)
It can measure the VSWR with respect to distance.(0 – 500
meter)
It can give multiple reading (up to 6) simultaneously.
It can store the measured traces up to 500.
New measured trace can be compared with the older one.
The traces can be imported or exported from the analyzer to
laptop.
It doesn’t require the BTS for the measurement of VSWR,
return loss, cable loss and insertion loss.
ADVANTAGES
REQUIRMENT
Calibration kit
DPS Sensor
50W element (freq. band 9ooMhz)
5W element (freq. band 900Mhz)
D9 type Rs-232 serial straight cable
Jumper adaptor 7/8”M to ½”M
Adaptor ½”M to 7/8”F
MANUFACTURER
ANRITSU
BIRD ELECTRONICS
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Bird Electronics -Site Analyzer
Operating Frequency: 780 – 2500 MHz
Model No.:- 2500 Ex
Put on the site analyzer by
pressing the button
Site Analyser 2500 EX
There are three different modes in Site
Analyzer as listed below:-
1. Measure Match Mode
2. Fault Location Mode
3. Measure Power Mode
Suppose site analyzer is initially in fault location
mode. So change the mode to measure match mode
to measure VSWR.
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Fault Location Mode
Press thisbutton toselect themode of siteanalyzer
Save/Recall
Auto Scale
Hold VSW
RDistance(meter)
1.0
0
1.5
450
Select Mode
Measure match
Fault Location
Power mode
Site Analyser 2500 EX
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Select Mode
Press this button to select the measure
match modeMeasure match
Fault Location
Power mode
Measure Match Mode
Save/Recall
Auto Scale
Hold VSW
RFrequency(MHz)
1.0
780
1.5
250
Site Analyser 2500 EX
Here we have to change the Frequency Band because Antenna & BTS working on specific Frequency band.
Suppose they are working on GSM- 900 Band.So we have to change the frequency from 890 to 960 MHz.
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match ModeSave/Recall
Auto Scale
Hold VSW
RFrequency(MHz)
1.0
780
1.5
250Press this button to select the
desired frequency
band
Measure Match Mode
Frequency
Limit
Site Analyser 2500 EX
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
780
2500
VSWR
Start
Stop
MHz
MHz
Measure Match ModeFrequency
Limit
Press this buttonto changefrequency Site Analyser 2500 EX
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
780
2500
VSWR
Start
Stop
MHz
MHz
Press Left/Right button to
select start frequency
Press Left/Right button to select stop frequency
Then press Enter
Then press Esc
780890
2500960
Site Analyser 2500 EX
Now Screen Changes to…………………
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match ModeSave/Recall
Auto Scale
Hold
VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Off
Here Calibration goes offbecause of changes infrequency band
Site Analyser 2500 EX
Now we have to calibrate Site Analyzer by using Calibration Kit.In calibration process we set the Site Analyzer internal loss into Zero. It means VSWR of site analyzer goes to 1 at zero meter distance(at the port of site analyzer). We calibrate site analyzer by connecting Open, Short & Load port of calibration kit to RF Antenna port of SA one by one.
Calibration Kit
Op
en
Sho
rt
Load
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Press this button
Open
Short
Load
Calibration
Site Analyser 2500 EX
Connect the Open port of Calkit with RF Antenna Port………….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Open
Short
Load
Calibration
Cal
ibra
tio
n K
it
Select this
buttona
Done
Site Analyser 2500 EX
Now disconnect the open port & connect theShort port of Calkit with RF Antenna port of SiteAnalyzer………………..
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Open
Short
Load
CalibrationSelect
this button Done
Done
Site Analyser 2500 EX
Now disconnect the Short port & connect the
Load port of Calkit with RF Antenna port of
Site Analyzer………………..
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Open
Short
Load
Calibration
Calibration Kit
Select this
button
Done
Done
Done
Site Analyser 2500 EX
When Load Done then Screen changes to …….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match Mode
Save/Recall
Auto Scale
Hold VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Full
Now Calibration FullHere appeared on thescreen
Site Analyser 2500 EX
Remove Calkit Now……
Now Site Analyzer is Ready forMeasurement….
Now connect the Adapter with RFAntenna port of Site Analyzer & theconnect Jumper cable with thisAdapter…….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match ModeSave/Recall
Auto Scale
Hold
VSW
R
Frequency(MHz)
1.0
890
1.5
960
Calibration Full
Jum
pe
r C
able
Adp
Press auto scale
buttonMeasure Match Mode
Save/Recall
Auto Scale
Hold
VSW
R
Frequency(MHz)
1.0
890
1.5
960
Site Analyser 2500 EX
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match ModeSave/Recall
Auto Scale
VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Full
Press thisbutton toActivate theMarker
Select Marker
Hold
M1
Activate
Site Analyser 2500 EX
Here to get exact value of VSWR, we use
Marker to read exact value…..
So press Activate button to activate Marker
on Site Analyzer……………
Then Screen changes to……………….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Select MarkerM1
Activate
Press thisbutton toactivate M1
Off
Press Esc
Site Analyser 2500 EX
When we press Escape the Screen changes
to……………
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match Mode
Save/Recall
Auto Scale
Hold
VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Full
M1
M1 1.24
910
Site Analyser 2500 EX
To move the marker at the peak value ofGraph press Top arrow button of the SiteAnalyzer. Then Screen changes to…………….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match Mode
Save/Recall
Auto Scale
Hold VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Full
M1
M1 1.38
930
M1
Press this buttonto shift marker onthe peak value
9101.24
Site Analyser 2500 EX
Here the it is shown that VSWR of the Antenna
line is 1.38 which is beyond the acceptable limit
i.e. 1.30.
So we have to rectify this fault. To rectify the
fault We have to change the mode of site analyzer
from measure match to fault location mode.
Now change the mode to fault location then
press auto scale button…..
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match ModeSave/Recall
Auto Scale
Hold
VSW
RFrequency(MHz)
1.0
890
1.5
960
Calibration Full
M1
M1 1.38
930Press thisbutton tochangethe mode
Select ModeMeasure match
Fault Location
Power mode
Site Analyser 2500 EX
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Fault Location Mode
VSW
RDistance(meter)
1.0
0
1.5
450
Calibration Full
Press thisbutton toselect faultlocation mode
Measure matchSelect Mode
Save/Recall
Auto Scale
Hold
Fault Location
Power mode
Site Analyser 2500 EX
Here we have to set the distance scale
as per the requirement i.e. the length of
transmission line intially it is 0 to 450.
To set the distance scale press config
button then screen changes to………….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Fault Location Mode
VSW
RDistance(meter)
1.0
890
1.5
960
Calibration Full
Save/Recall
Auto Scale
Hold
PressthisButton
Distance
Limit
Site Analyser 2500 EX
Select Distance then Screen changes
to……….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match Mode
Distance
Limit
Press this button to
distance limit
0Start Distance
Stop Distance
Mix Distance
450
450
m
m
m
Site Analyser 2500 EX
Select stop distance by pressing left/right
arrow button & enter distance by using
numeric key pad……………
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Measure Match Mode
Distance
Limit
0Start Distance
Stop Distance
Mix Distance
450
450
m
m
m
Press thisbutton to selectstop distance
35
Press Esc
Press Enter
Site Analyser 2500 EX
Now the screen changes to……………
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Fault Location Mode
VSW
RDistance(meter)
1.0
0
1.5
35
Calibration Full
Save/Recall
Auto Scale
Hold
Site Analyser 2500 EX
Now to measure exact distance where the
fault occur, we have to use marker. So
activate it first.
To activate marker press Marker button
then screen changes to…..
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Select Marker
M1
Activate
Press thisbutton toactivate M1
Off
Press Esc
Press this button to
select marker
Site Analyser 2500 EX
When we press Escape the Screen changes
to……………
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Fault Location Mode
VSW
RDistance(meter)
1.0
0
1.5
35
Calibration Full
Save/Recall
Auto Scale
Hold
M1
M1 1.01
14
Site Analyser 2500 EX
To move the marker at the peak value ofGraph press Top arrow button of the SiteAnalyzer. Then Screen changes to…………….
PWR
CHRG
Fault Location Mode
VSW
RDistance(meter)
1.0
0
1.5
35
Calibration Full
Save/Recall
Auto Scale
Hold
M1
M1 1.01
14 Press this buttonto shift marker onthe peak value
Fault Location Mode
VSW
RDistance(meter)
1.0
0
1.5
35
Save/Recall
Auto Scale
Hold
M1
M1 1.28
31
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Site Analyser 2500 EX
Here the fault is at 31m distance. Here we didn’t
consider the VSWR value whatever it is. value is
not used to measure VSWR. The achieved value of
VSWR means in Measure match mode.
According to the graph fault is at 31m distance
which may be at Antenna port or O/D Jumper
cable.
Rectify the fault & measure the VSWR in Measure
match. If still the VSWR value is high again repeat
& rectify fault.
Repeat this action till VSWR goes below
1.30(means 1.30 in measure match mode).
To save the reading press Save/Recall
selection button.
(Reading can be save either in Measure
match mode or Fault location mode. Site
master will save both the value at once).
The screen changes to……………….
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
VSW
RDistance(meter)
1.00
1.5
35
Calibration Full
Save/Recall
Auto Scale
Hold
M1
Fault Location Mode
M1
1.28
31
Save
Recall
Edit
Delete
Techvidhya -1M- 20/08/12
Press this button the
screen to save the value
Site Analyser 2500 EX
PWR
CHRG
Press this button to save the current trace
Save
Recall
Edit
Delete
Nokia -1M- 20/08/12
A F K P U Z ,,
B G L Q V [ ,
C H M R W ] Space
D I N S X = !
E J O T Y * #
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Site Analyser 2500 EX
Now give the name of the trace file that you
want to save as by using Alphabets,
characters appeared on the screen with the
help of selection buttons…..
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
A F K P U Z ,,
B G L Q V [ ,
C H M R W ] Space
D I N S X = !
E J O T Y *#
TECH VIDHYA # 8/20 / 12
Now PressEnter toSave file
Site Analyser 2500 EX
After giving the name when we press
Enter the will be saved & Screen close
now & return to the previous state
Measure match or Fault location mode.
Measure Power from Site Analyzer
Insert Sensor on in between BTS to Antenna connection by using Jumper Adaptor & Adaptor. Now connect this Sensor to RS232 port by using Serial straight cable.
Now to enter into measure power mode press mode button.
PWR
CHRG
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Bird Electronics -Site
Analyzer
Operating Frequency: 780 – 2500 MHz
Model No.:- 2500 Ex
Now Press this button to select the mode of site analyzer
Select ModeMeasure match
Fault Location
Power mode
BTS
An
ten
na
50 watt 5 watt
Sensor
RS232 port
Site Analyser 2500 EX
PWR
CHRG
Select ModeMeasure match
Warning
Do not apply external power to
RF Antenna port of site
analyzer
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Press thisbutton toselect themeasurePowermode
Fault Location
Power mode
Searching Sensor
Site Analyser 2500 EX
Here, a warning appear on the screen that “do not
apply external power to RF Antenna port of site
analyzer”. Because Site Analyzer may get damaged
due to high power entering into it.
--------------------------------
When the searching is complete. The screen
changes now to…………
PWR
CHRG
BTS
An
ten
na
50 watt 5 watt
Sensor
Measure Power
50
0FWD:REF :
Watt
__ dBm__ dBm
WattWatt
dBm
1 2 3
4
7
#
5
8
0
6
9
*/+
ESC
ENTR
Site Analyser 2500 EX
Press thisbutton to getvalue in watt