Page 1: Industrail Trainining in Telecommunication

Presented BySUMIT SINGH

Page 2: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Site Analyser 2500 EX

FRONT VIEW OF SITE ANALYSER

Page 3: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Site Analyser 2500 EX

ON / OFF

NIGHT

VISION

LED

Sel

ecti

on

Bu

tto

ns

Function buttonsNumeric Keypad

Arr

ow

key

bu

tto

ns

FRONT VIEW OF SITE ANALYSER

Page 4: Industrail Trainining in Telecommunication

CHRGPWR

CHRG

ON / OFF

NIGHT

VISION

LED

Page 5: Industrail Trainining in Telecommunication

Use to select the

particular functions

adjacent to it.

SELECTION BUTTONS

Sel

ecti

on

Bu

tto

ns

Page 6: Industrail Trainining in Telecommunication

Config : To select the freq. range in measure

match mode and Distance range in

fault location mode.

Mode : Use to select the mode.

Calibration : It use to set the internal loss

of site analyzer to zero.

Marker : Use to mark the exact position

on the graph.

FUNCTION BUTTONS

Page 7: Industrail Trainining in Telecommunication

7 8 9

4

1

0

5

2

_

6

3

-/+ES

CEN

TR

It is used to insert the values during

the selection of frequency range and

distance range.

NUMERIC KEYPED

Page 8: Industrail Trainining in Telecommunication

Up

Down

RightLeft

Using these four arrow keys we can shift the marker to

the desired position

( Up key for max. VSWR, Down key for min. VSWR,

Left/Right key to move the marker along with the trace)

Also we use Left/Right key during the selection of

freq. range & dist. Range.

ARROW KEY BUTTONS

Page 9: Industrail Trainining in Telecommunication

DO NOT APPLY EXTERNAL

PWR TO IT

Charging Port

RS

232 P

ort

Printer Port

RF Antenna Port ½’’ F

TOP VIEW OF SITE ANALYSER

Page 10: Industrail Trainining in Telecommunication

To measure the VSWR.

To measure the return loss.

To measure the cable loss.

To measure the insertion loss.

To measure the forward power.

To measure the reflected power.

USES

Page 11: Industrail Trainining in Telecommunication

It gives graphical representation of the measurement.

It can measure the VSWR with respect to frequency.(780

MHz – 2500 MHz)

It can measure the VSWR with respect to distance.(0 – 500

meter)

It can give multiple reading (up to 6) simultaneously.

It can store the measured traces up to 500.

New measured trace can be compared with the older one.

The traces can be imported or exported from the analyzer to

laptop.

It doesn’t require the BTS for the measurement of VSWR,

return loss, cable loss and insertion loss.

ADVANTAGES

Page 12: Industrail Trainining in Telecommunication

REQUIRMENT

Calibration kit

DPS Sensor

50W element (freq. band 9ooMhz)

5W element (freq. band 900Mhz)

D9 type Rs-232 serial straight cable

Jumper adaptor 7/8”M to ½”M

Adaptor ½”M to 7/8”F

Page 13: Industrail Trainining in Telecommunication

MANUFACTURER

ANRITSU

BIRD ELECTRONICS

Page 14: Industrail Trainining in Telecommunication
Page 15: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Bird Electronics -Site Analyzer

Operating Frequency: 780 – 2500 MHz

Model No.:- 2500 Ex

Put on the site analyzer by

pressing the button

Site Analyser 2500 EX

Page 16: Industrail Trainining in Telecommunication

There are three different modes in Site

Analyzer as listed below:-

1. Measure Match Mode

2. Fault Location Mode

3. Measure Power Mode

Suppose site analyzer is initially in fault location

mode. So change the mode to measure match mode

to measure VSWR.

Page 17: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Fault Location Mode

Press thisbutton toselect themode of siteanalyzer

Save/Recall

Auto Scale

Hold VSW

RDistance(meter)

1.0

0

1.5

450

Select Mode

Measure match

Fault Location

Power mode

Site Analyser 2500 EX

Page 18: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Select Mode

Press this button to select the measure

match modeMeasure match

Fault Location

Power mode

Measure Match Mode

Save/Recall

Auto Scale

Hold VSW

RFrequency(MHz)

1.0

780

1.5

250

Site Analyser 2500 EX

Page 19: Industrail Trainining in Telecommunication

Here we have to change the Frequency Band because Antenna & BTS working on specific Frequency band.

Suppose they are working on GSM- 900 Band.So we have to change the frequency from 890 to 960 MHz.

Page 20: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match ModeSave/Recall

Auto Scale

Hold VSW

RFrequency(MHz)

1.0

780

1.5

250Press this button to select the

desired frequency

band

Measure Match Mode

Frequency

Limit

Site Analyser 2500 EX

Page 21: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

780

2500

VSWR

Start

Stop

MHz

MHz

Measure Match ModeFrequency

Limit

Press this buttonto changefrequency Site Analyser 2500 EX

Page 22: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

780

2500

VSWR

Start

Stop

MHz

MHz

Press Left/Right button to

select start frequency

Press Left/Right button to select stop frequency

Then press Enter

Then press Esc

780890

2500960

Site Analyser 2500 EX

Page 23: Industrail Trainining in Telecommunication

Now Screen Changes to…………………

Page 24: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match ModeSave/Recall

Auto Scale

Hold

VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Off

Here Calibration goes offbecause of changes infrequency band

Site Analyser 2500 EX

Page 25: Industrail Trainining in Telecommunication

Now we have to calibrate Site Analyzer by using Calibration Kit.In calibration process we set the Site Analyzer internal loss into Zero. It means VSWR of site analyzer goes to 1 at zero meter distance(at the port of site analyzer). We calibrate site analyzer by connecting Open, Short & Load port of calibration kit to RF Antenna port of SA one by one.

Calibration Kit

Op

en

Sho

rt

Load

Page 26: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Press this button

Open

Short

Load

Calibration

Site Analyser 2500 EX

Page 27: Industrail Trainining in Telecommunication

Connect the Open port of Calkit with RF Antenna Port………….

Page 28: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Open

Short

Load

Calibration

Cal

ibra

tio

n K

it

Select this

buttona

Done

Site Analyser 2500 EX

Page 29: Industrail Trainining in Telecommunication

Now disconnect the open port & connect theShort port of Calkit with RF Antenna port of SiteAnalyzer………………..

Page 30: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Open

Short

Load

CalibrationSelect

this button Done

Done

Site Analyser 2500 EX

Page 31: Industrail Trainining in Telecommunication

Now disconnect the Short port & connect the

Load port of Calkit with RF Antenna port of

Site Analyzer………………..

Page 32: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Open

Short

Load

Calibration

Calibration Kit

Select this

button

Done

Done

Done

Site Analyser 2500 EX

Page 33: Industrail Trainining in Telecommunication

When Load Done then Screen changes to …….

Page 34: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match Mode

Save/Recall

Auto Scale

Hold VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Full

Now Calibration FullHere appeared on thescreen

Site Analyser 2500 EX

Page 35: Industrail Trainining in Telecommunication

Remove Calkit Now……

Page 36: Industrail Trainining in Telecommunication

Now Site Analyzer is Ready forMeasurement….

Now connect the Adapter with RFAntenna port of Site Analyzer & theconnect Jumper cable with thisAdapter…….

Page 37: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match ModeSave/Recall

Auto Scale

Hold

VSW

R

Frequency(MHz)

1.0

890

1.5

960

Calibration Full

Jum

pe

r C

able

Adp

Press auto scale

buttonMeasure Match Mode

Save/Recall

Auto Scale

Hold

VSW

R

Frequency(MHz)

1.0

890

1.5

960

Site Analyser 2500 EX

Page 38: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match ModeSave/Recall

Auto Scale

VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Full

Press thisbutton toActivate theMarker

Select Marker

Hold

M1

Activate

Site Analyser 2500 EX

Page 39: Industrail Trainining in Telecommunication

Here to get exact value of VSWR, we use

Marker to read exact value…..

So press Activate button to activate Marker

on Site Analyzer……………

Then Screen changes to……………….

Page 40: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Select MarkerM1

Activate

Press thisbutton toactivate M1

Off

Press Esc

Site Analyser 2500 EX

Page 41: Industrail Trainining in Telecommunication

When we press Escape the Screen changes

to……………

Page 42: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match Mode

Save/Recall

Auto Scale

Hold

VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Full

M1

M1 1.24

910

Site Analyser 2500 EX

Page 43: Industrail Trainining in Telecommunication

To move the marker at the peak value ofGraph press Top arrow button of the SiteAnalyzer. Then Screen changes to…………….

Page 44: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match Mode

Save/Recall

Auto Scale

Hold VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Full

M1

M1 1.38

930

M1

Press this buttonto shift marker onthe peak value

9101.24

Site Analyser 2500 EX

Page 45: Industrail Trainining in Telecommunication

Here the it is shown that VSWR of the Antenna

line is 1.38 which is beyond the acceptable limit

i.e. 1.30.

So we have to rectify this fault. To rectify the

fault We have to change the mode of site analyzer

from measure match to fault location mode.

Now change the mode to fault location then

press auto scale button…..

Page 46: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match ModeSave/Recall

Auto Scale

Hold

VSW

RFrequency(MHz)

1.0

890

1.5

960

Calibration Full

M1

M1 1.38

930Press thisbutton tochangethe mode

Select ModeMeasure match

Fault Location

Power mode

Site Analyser 2500 EX

Page 47: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Fault Location Mode

VSW

RDistance(meter)

1.0

0

1.5

450

Calibration Full

Press thisbutton toselect faultlocation mode

Measure matchSelect Mode

Save/Recall

Auto Scale

Hold

Fault Location

Power mode

Site Analyser 2500 EX

Page 48: Industrail Trainining in Telecommunication

Here we have to set the distance scale

as per the requirement i.e. the length of

transmission line intially it is 0 to 450.

To set the distance scale press config

button then screen changes to………….

Page 49: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Fault Location Mode

VSW

RDistance(meter)

1.0

890

1.5

960

Calibration Full

Save/Recall

Auto Scale

Hold

PressthisButton

Distance

Limit

Site Analyser 2500 EX

Page 50: Industrail Trainining in Telecommunication

Select Distance then Screen changes

to……….

Page 51: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match Mode

Distance

Limit

Press this button to

distance limit

0Start Distance

Stop Distance

Mix Distance

450

450

m

m

m

Site Analyser 2500 EX

Page 52: Industrail Trainining in Telecommunication

Select stop distance by pressing left/right

arrow button & enter distance by using

numeric key pad……………

Page 53: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Measure Match Mode

Distance

Limit

0Start Distance

Stop Distance

Mix Distance

450

450

m

m

m

Press thisbutton to selectstop distance

35

Press Esc

Press Enter

Site Analyser 2500 EX

Page 54: Industrail Trainining in Telecommunication

Now the screen changes to……………

Page 55: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Fault Location Mode

VSW

RDistance(meter)

1.0

0

1.5

35

Calibration Full

Save/Recall

Auto Scale

Hold

Site Analyser 2500 EX

Page 56: Industrail Trainining in Telecommunication

Now to measure exact distance where the

fault occur, we have to use marker. So

activate it first.

To activate marker press Marker button

then screen changes to…..

Page 57: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Select Marker

M1

Activate

Press thisbutton toactivate M1

Off

Press Esc

Press this button to

select marker

Site Analyser 2500 EX

Page 58: Industrail Trainining in Telecommunication

When we press Escape the Screen changes

to……………

Page 59: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Fault Location Mode

VSW

RDistance(meter)

1.0

0

1.5

35

Calibration Full

Save/Recall

Auto Scale

Hold

M1

M1 1.01

14

Site Analyser 2500 EX

Page 60: Industrail Trainining in Telecommunication

To move the marker at the peak value ofGraph press Top arrow button of the SiteAnalyzer. Then Screen changes to…………….

Page 61: Industrail Trainining in Telecommunication

PWR

CHRG

Fault Location Mode

VSW

RDistance(meter)

1.0

0

1.5

35

Calibration Full

Save/Recall

Auto Scale

Hold

M1

M1 1.01

14 Press this buttonto shift marker onthe peak value

Fault Location Mode

VSW

RDistance(meter)

1.0

0

1.5

35

Save/Recall

Auto Scale

Hold

M1

M1 1.28

31

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Site Analyser 2500 EX

Page 62: Industrail Trainining in Telecommunication

Here the fault is at 31m distance. Here we didn’t

consider the VSWR value whatever it is. value is

not used to measure VSWR. The achieved value of

VSWR means in Measure match mode.

According to the graph fault is at 31m distance

which may be at Antenna port or O/D Jumper

cable.

Rectify the fault & measure the VSWR in Measure

match. If still the VSWR value is high again repeat

& rectify fault.

Repeat this action till VSWR goes below

1.30(means 1.30 in measure match mode).

Page 63: Industrail Trainining in Telecommunication

To save the reading press Save/Recall

selection button.

(Reading can be save either in Measure

match mode or Fault location mode. Site

master will save both the value at once).

The screen changes to……………….

Page 64: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

VSW

RDistance(meter)

1.00

1.5

35

Calibration Full

Save/Recall

Auto Scale

Hold

M1

Fault Location Mode

M1

1.28

31

Save

Recall

Edit

Delete

Techvidhya -1M- 20/08/12

Press this button the

screen to save the value

Site Analyser 2500 EX

Page 65: Industrail Trainining in Telecommunication

PWR

CHRG

Press this button to save the current trace

Save

Recall

Edit

Delete

Nokia -1M- 20/08/12

A F K P U Z ,,

B G L Q V [ ,

C H M R W ] Space

D I N S X = !

E J O T Y * #

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Site Analyser 2500 EX

Page 66: Industrail Trainining in Telecommunication

Now give the name of the trace file that you

want to save as by using Alphabets,

characters appeared on the screen with the

help of selection buttons…..

Page 67: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

A F K P U Z ,,

B G L Q V [ ,

C H M R W ] Space

D I N S X = !

E J O T Y *#

TECH VIDHYA # 8/20 / 12

Now PressEnter toSave file

Site Analyser 2500 EX

Page 68: Industrail Trainining in Telecommunication

After giving the name when we press

Enter the will be saved & Screen close

now & return to the previous state

Measure match or Fault location mode.

Page 69: Industrail Trainining in Telecommunication

Measure Power from Site Analyzer

Insert Sensor on in between BTS to Antenna connection by using Jumper Adaptor & Adaptor. Now connect this Sensor to RS232 port by using Serial straight cable.

Now to enter into measure power mode press mode button.

Page 70: Industrail Trainining in Telecommunication

PWR

CHRG

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Bird Electronics -Site

Analyzer

Operating Frequency: 780 – 2500 MHz

Model No.:- 2500 Ex

Now Press this button to select the mode of site analyzer

Select ModeMeasure match

Fault Location

Power mode

BTS

An

ten

na

50 watt 5 watt

Sensor

RS232 port

Site Analyser 2500 EX

Page 71: Industrail Trainining in Telecommunication

PWR

CHRG

Select ModeMeasure match

Warning

Do not apply external power to

RF Antenna port of site

analyzer

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Press thisbutton toselect themeasurePowermode

Fault Location

Power mode

Searching Sensor

Site Analyser 2500 EX

Page 72: Industrail Trainining in Telecommunication

Here, a warning appear on the screen that “do not

apply external power to RF Antenna port of site

analyzer”. Because Site Analyzer may get damaged

due to high power entering into it.

--------------------------------

When the searching is complete. The screen

changes now to…………

Page 73: Industrail Trainining in Telecommunication

PWR

CHRG

BTS

An

ten

na

50 watt 5 watt

Sensor

Measure Power

50

0FWD:REF :

Watt

__ dBm__ dBm

WattWatt

dBm

1 2 3

4

7

#

5

8

0

6

9

*/+

ESC

ENTR

Site Analyser 2500 EX

Press thisbutton to getvalue in watt

Page 74: Industrail Trainining in Telecommunication