indice mini-contattori / contents mini-contactors … mincontattori it-en.pdf · motori trifase...
TRANSCRIPT
1-471-471-471-47471-47
CONTROLLO MOTOREMOTOR CONTROL
1
IndiceContents
INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS
Criteri di scelta pag. 1- 48Product selection
Caratteristiche tecniche pag. 1- 51Tecnical data
MINI - CONTATTORIMINI CONTACTORS
1-48
1
0,19
0,16
Riferimento diordinazione
CONTATTORI TRIPOLARI circuito di comando c.a.THREE-POLE CONTACTORS a.c. control
CONTATTORI TRIPOLARI circuito di comando c.c.THREE-POLE CONTACTORS d.c. control
CONTATTORI TETRAPOLARI circuito di comando c.a.FOUR-POLE CONTACTORS a.c. control
CONTATTORI TETRAPOLARI circuito di comando c.c. (2)
FOUR-POLE CONTACTORS d.c. control (2)
Potenza nominalemotori trifase 50-60Hz3-phase motors50-60Hz rated power
AC-2, AC-3220V240V
380V440V
500V690V
kW kW kW
380V400V
A
CorrentenominaleRated currentAC-2, AC-3
CollegamentiConnections
ContattiausiliariAuxiliarycontactsNO NC
Cataloguenumber
Tensione dicomandoControlvoltage
PesoWeight
Kg
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
per circuito stampato
per circuito stampatofor printed circuit
per circuito stampatofor printed circuit
per circuito stampatofor printed circuit
3 4 4 9
4 5,5 5,5 12
3 4 4 9
4 5,5 5,5 12
A
20
20
CollegamentiConnections
ContattiausiliariAuxiliarycontacts
Riferimento diordinazioneCataloguenumber
Tensione dicomando Peso
WeightRated currentCorrente nominale
AC-1 690V
Kg
0,161 -- 1
1 -
1 -- 1
- 1
0,16GHMC.3.01
0,16GHMCP.3.100,16GHMCP.3.01
0,16GHMD.3.10GHMD.3.01
0,19GHMC.3.101 -- 1
1 -
1 -- 1
- 1
0,19GHMC.3.01
0,19GHMCP.3.100,19GHMCP.3.01
0,19GHMD.3.10GHMD.3.01
- -
- -
- -
- -
GHMC.4.00GHMD.4.00
GHMCP.4.00
GHMCP.4.00
0,16
0,16
0,19
0,19
(1) Completare il riferimento con la tensione e la frequenza della bobina di comando.Le tensioni normalizzate disponibili sono le seguenti:Complete catalogue number with details of voltage and frequency control circuit coil.Standard available control voltages are the following:
24V 50-60Hz 24V DC110V 50Hz e 120V 60Hz 48V DC220-230V 50Hz e 240V 60Hz 110V DC380-400V 50Hz e 440V 60Hz
(2) Sono disponibili su richiesta mini-contattori con poli principali 2NO+2NC (es. GHMC.22.00).Mini-contactors with 2NO+2NC main poles (ex. GHMC.22.00) are also available on request.
Criteri di sceltaProduct selection
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)
(1)
(1)
(1)
Controlvoltage
for printed circuit
GHMC.3.10
GHMC.4.00GHMD.4.00
1-491-491-491-49491-49
CONTROLLO MOTOREMOTOR CONTROL
1
Riferimento diordinazione
INVERTITORI TRIPOLARI circuito di comando c.a.THREE-POLE REVERSERS a.c. control
INVERTITORI TRIPOLARI circuito di comando c.c.THREE-POLE REVERSERS d.c. control
INVERTITORI TETRAPOLARI circuito di comando c.a.FOUR-POLE REVERSERS a.c. control
INVERTITORI TETRAPOLARI circuito di comando c.c.FOUR-POLE REVERSERS d.c. control
Potenza nominalemotori trifase 50-60Hz3-phase motors50-60Hz rated power
AC-2, AC-3220V240V
380V440V
500V690V
kW kW kW
380V400V
A
CorrentenominaleRated currentAC-2, AC-3
CollegamentiConnections
ContattiausiliariAuxiliarycontactsNO NC
Cataloguenumber
Tensione dicomandoControlvoltage
PesoWeight
Kg
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
vite-serrafiloscrew terminals
per circuito stampatofor printed circuit
per circuito stampatofor printed circuit
per circuito stampatofor printed circuit
per circuito stampatofor printed circuit
3 4 4 9
4 5,5 5,5 12
3 4 4 9
4 5,5 5,5 12
A
20
20
CollegamentiConnections
ContattiausiliariAuxiliarycontacts
Riferimento diordinazioneCataloguenumber
Tensione dicomandoControlvoltage
PesoWeight
Rated currentCorrente nominaleAC-1 690V
Kg
0,32GHMC.3.10/R1 -- 1
1 -
1 -- 1
- 1
0,32GHMC.3.01/R
0,32GHMCP.3.10/R0,32GHMCP.3.01/R
0,32GHMD.3.10/R0,32GHMD.3.01/R
0,38GHMC.3.10/R1 -- 1
1 -
1 -- 1
- 1
0,38GHMC.3.01/R
0,38GHMCP.3.10/R0,38GHMCP.3.01/R
0,38GHMD.3.10/R0,38GHMD.3.01/R
- -
- -
- -
- -
GHMC.4.00/R
GHMCP.4.00/R
GHMC.4.00/R
GHMCP.4.00/R
0,32
0,32
0,38
0,38
Criteri di sceltaProduct selection
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)(1)
(1)
(1)
(1)
(1)
(1) Completare il riferimento con la tensione e la frequenza della bobina di comando.Le tensioni normalizzate disponibili sono le seguenti:Complete catalogue number with details of voltage and frequency control circuit coil.Standard available control voltages are the following:
24V 50-60Hz 24V DC110V 50Hz e 120V 60Hz 48V DC220-230V 50Hz e 240V 60Hz 110V DC380-400V 50Hz e 440V 60Hz
MINI - CONTATTORIMINI CONTACTORS
1-50
1
Riferimento diordinazione
CONTATTORI AUSILIARI circuito di comando c.a.AUXILIARY CONTACTORS a.c. controlCorrentetermica Ith
Thermalcurrent Ith
A A
230V
A
CorrentenominaleRatedcurrentAC-15
CollegamentiConnections
ContattiContacts
NO NC
Cataloguenumber
Tensione dicomandoControlvoltage
PesoWeight
Kg
vite-serrafiloscrew terminals
10 3 2 0,16GHMR.404 -3 1 0,16GHMR.31
400V
0,16GHMR.22
vite-serrafiloscrew terminals10 3 2
0,19GHMR.404 -3 1 0,19GHMR.312 2 0,19GHMR.22
CONTATTORI AUSILIARI circuito di comando c.c.AUXILIARY CONTACTORS d.c. control
vite-serrafiloscrew terminals
10 3 20,04GHTR.111 1
- 2
2 2
0,04GHTR.02
0,04GHTR.224 - 0,04GHTR.40
BLOCCHETTI AGGIUNTIVI DI CONTATTI AUSILIARIADDITIONAL AUXILIARY CONTACT BLOCKS
(1) Completare il riferimento con la tensione e la frequenza della bobina di comando.Le tensioni normalizzate disponibili sono le seguenti:Complete catalogue number with details of voltage and frequency control circuit coil.Standard available control voltages are the following:
24V 50-60Hz 24V DC110V 50Hz e 120V 60Hz 48V DC220-230V 50Hz e 240V 60Hz 110V DC380-400V 50Hz e 440V 60Hz
(2) Da utilizzare nel caso di invertitore per il contattore sinistroTo use for the left contactor of the reverser
2 2
Criteri di sceltaProduct selection
0,04GHTR.11.V (2)1 1
(1)(1)(1)
(1)(1)(1)
1-511-511-511-51511-51
CONTROLLO MOTOREMOTOR CONTROL
1
(1) GHMC, MD, MR, GHTR Adatto a 690V per: sistemi con neutro a terra, categoria di sovratensioneda I a IV, grado di inquinamento 3 (industriale normale): Uimp = 8kV
GHMCP, MRP Adatto a 690V con grado di inquinamento 2, Uimp = 6kV
Grado di inquinamento 3: Ui = 690V con circuito stampato CTI≥ 600Ui = 500V con circuito stampato CTI≥ 400Ui = 400V con circuito stampato CTI≥ 100
(1) GHMC, MD, MR, GHTR Suitable at 690V for: earthed-neutral systems, overvoltagecategory I to IV, pollution degree 3 (standard-industry): Uimp
= 8kV. GHMCP, MRP Suitable at 690V for pollution degree 2, Uimp = 6kV
Pollution degree 3: Ui = 690V printed circuit CTI≥ 600Ui = 500V printed circuit CTI≥ 400Ui = 400V printed circuit CTI≥ 100
CARATTERISTICHE TECNICHE SECONDO LE NORME EN 60947-4-1DATA ACCORDING TO IEC 60947-4-1
Contatti di potenza Main contacts GHMCGHMCP
GHMD
Tensione di isolamentoPotere di chiusuraPotere di interruzionecos ϕ 0,65
Rated insulation voltageMaking capacityBreaking capacitycos ϕ 0,65
UiUe = 690V a.c.400V a.c.500V a.c.690V a.c.
[V] a.c.[A][A][A][A]
690 (1)
1651009080
690 (1)
1651009080
Categoria di impiego AC-1comando di carichi resistiviMax. 40°C corrente nominale Ie (=Ith) a giornoPotenza max. carichi trifase resistivi
Utilization category AC-1switching of resistive loadsRated operational current Ie (=Ith) at 40°C, openRated operational power of three-phaseresistive loads 230V
240V400V415V
[kW][kW][kW][kW][A][kW][kW][kW][kW][mm2]
[A] 20 20
7,98,313,814,3166,36,711
11,52,5
7,98,313,814,3166,36,711
11,52,5
230V240V400V415V
Max. 60°C corrente nominale Ie (=Ithe ) in cassettaPotenza max. carichi trifase resistivi
Rated operational current Ie (=Ithe ) at 60°C, enclosedRated operational power ofthree-phase resistive loads
Sezione minima connessioni a Ie Minimum cross-section of conductor at Ie
Categoria di impiego AC-2, AC-3comando di motori elettrici trifaseCorrente nominale Ie
Utilization category AC-2, AC-3switching of three-phase motorsRated operational current Ie 220V
230V240V380 - 400V415 - 440V500V660 - 690V220 - 240V380 - 440V500 - 690V
[A][A][A][A][A][A][A][kW][kW][kW]
1514,51412119
6,54
5,55,5
1211,5119875344
Potenza nominale di motori trifase Rated operational power ofthree-phase motors
Categoria di impiego AC-4comando di motori a gabbia, frenaturain controcorrente, marcia ad impulsiCorrente nominale Ie
Utilization category AC-4switching of squirrel cage motors,plugging, inchingRated operational current Ie 220V
230V240V380 - 400V415 - 440V500V660 - 690V220 - 240V380 - 440V500 - 690V
[A][A][A][A][A][A][A][kW][kW][kW]
1514,51412119
6,54
5,55,5
1211,5119875344
Potenza nominale di motori trifase Rated operational power ofthree-phase motors
Categoria di impiego DC-1comando di carichi resistivi in c.c.Costante di tempo L / R ≤ 1msCorrente nominale Ie
Utilization category DC-1switching of d.c. resistive loadsTime costant L / R ≤ 1msRated operational current Ie
[A][A][A][A][A][A][A][A]
20205
0,620202016
20205
0,620202016
1 polo / 1 pole 24V60V
110V220V
3 poli in serie / 3 poles in series 24V60V
110V220V
Caratteristiche tecnicheTechnical data
MINI - CONTATTORIMINI CONTACTORS
1-52
1
(1) Vedi nota pag. 1-51 See note page 1-51
Contatti di potenza Main contacts GHMCGHMCP GHMD
Categoria di impiego DC-3 e DC-5comando di motori in c.c.Costante di tempo L / R ≤ 15 msCorrente nominale Ie
Utilization category DC-3 and DC-5switching of shunt and series d.c. motorsTime costant L / R ≤ 15 msRated operational current Ie
[A][A][A][A][A][A][A][A]
2051
0,152020202
2051
0,152020202
1 polo / 1 pole 24V60V
110V220V
3 poli in serie / 3 poles in series 24V60V
110V220V
Max. temperatura ambienteFunzionamento a giorno
in cassettaCon relè termico a giorno
in cassettaStoccaggio
Max. ambient temperatureOperation open
enclosedWith thermal o/l relay open
enclosedStorage
[°C][°C][°C][°C][°C]
-40 +60-40 +40-25 +60-25 +40-50 +90
-40 +60-40 +40-25 +60-25 +40-50 +90
Protezione contro il corto circuitoper contattore senza relè termico
coordinamento tipo 1secondo EN 60947-4-1
coordinamento tipo 2secondo EN 60947-4-1
Short circuit protectionfor contactor without thermal relay
coordination-type 1according to IEC 60947-4-1 gL (gG)
coordination-type 2according to IEC 60947-4-1 gL (gG)
[A] 4040
[A] 2525
Sezione delle connessionirigide o semirigideflessibiliflessibili con puntalino
Numero cavi per terminale
Cable cross-sectionssolid or strandedflexibleflexible with multicore cable end
Cables per terminal
[mm2][mm2][mm2]
0.5 - 2.50.5 - 2.50.5 - 1.5
2
0.5 - 2.50.5 - 2.50.5 - 1.5
2Max. frequenza di manovreContattore senza relè termico
Frequency of operations a vuoto / without loadContactor without relay AC-3 Ie
AC-4 IeDC-3 Ie
[op/h][op/h][op/h][op/h]
10000700150700
10000600120600
[A] 12096Corrente di breve durata Short time current 10s[W] 0.250.15Potenza dissipata per polo a: Power loss per pole at: max. Ie AC-3 400V[106 op][106 op]
515
515
Durata meccanica
Fissaggio
Mechanical endurance A.C.D.C.
Fixing
Contatti ausiliari Auxiliary contacts GHMRGHMRP GHTR
[V] a.c.[A][A]
690 (1)
106
690 (1)
106
Tensione di isolamentoCorrente termica Ith
Rated insulation voltage UiThermal current Ith max. 40°C
max. 60°C[W] 0.50.5Potenza dissipata per polo a Ith Power loss per pole at Ith
Categoria di impiego AC-15Corrente nominale Ie
Utilization category AC-15 220-240VRated operational current Ie 380-415V
440V500V660-690V
[A][A][A][A][A]
32
1,61,20,6
32
1,61,20,6
Categoria di impiego DC-13Corrente nominale Ie
Utilization category DC-13 60VRated operational current Ie 110V
220V
[A][A][A]
20,40,1
20,40,1
Max. temperatura ambienteFunzionamento a giorno
in cassettaStoccaggio
Max. ambient temperatureOperation open
enclosedStorage
[°C][°C][°C]
-40 +60-40 +40-40 +90
-40 +60-40 +40-40 +90
Protezione contro il corto circuitocorrente di corto circuito 1 kA
Short circuit protectionshort-circuit current 1 kA gG [A] 2020
Sezione delle connessionirigide o semirigideflessibiliflessibili con puntalino
Numero cavi per terminale
Cable cross-sectionssolid or strandedflexibleflexible with multicore cable end
Cables per terminal
[mm2][mm2][mm2]
0.75 - 2.50.75 - 2.50.5 - 1.5
2
0.75 - 2.50.75 - 2.50.5 - 1.5
2
viti/screw o/or DIN
Caratteristiche tecnicheTechnical data
1-531-531-531-53531-53
CONTROLLO MOTOREMOTOR CONTROL
1
Dati secondo UL Data according to UL
(1) Pollution degreeCTI - PWB
Ui
2≥ 100600V
3≥ 400480V
3100...400
240V
Circuito di comando Control circuit
Assorbimento bobinaCorrente alternata
Corrente continua
Power consumption of coilsA.C. operated
D.C. operated
254 - 51,22,52,5
[VA][VA][W][W][W]
Campo di funzionamento della bobinain multipli della tensione di comando Us
Tempo di funzionamentoa tensione di comando Us ± 10%Corrente alternata tempo di chiusura
tempo di rilasciodurata dell'arco
Corrente continua tempo di chiusuratempo di rilasciodurata dell'arco
Operation range of coilsin multiplies of control voltage Us
Switching timeat control voltage Us ± 10%A.C. operated
D.C. operated
0,85 - 1.10.8 - 1.1
[ms][ms][ms][ms][ms][ms]
spunto / inrushritenuta / sealed
spunto / inrushritenuta / sealed
make timerelease timearc durationmake timerelease timearc duration
15 - 258 - 25
10 - 1515 - 198 - 25
10 - 15
GHMC* GHMD* GHMR*
Corrente nominale "General Use"
Potenza max. motori trifase 60 Hz
Potenza max. motori monofase 60 Hz
FusibiliCorrente massima di c.c. presunta
Tensione nominale
Rated operational current "General Use"
Rated operational power ofthree-phase motors at 60 Hz
Rated operational power ofsingle-phase motors at 60 Hz
FusesMax. short circuit prospective current
Rated voltage
[HP][HP][HP][HP][HP][HP][HP][HP][A][A][V][V]
115V200V230V460V575V115V200V230V
15
1,5335
7,50,51
1,530
5000600600
[A] 20
233
7,510
0,751,52
305000600600
10
-----------
600
Contatti ausiliaricodice di designazione
Auxiliary contactsswitching capacity A600
Q600A600Q600
A600Q600
A.C.D.C.
Versioni omologate UL / UL listed types:Contattori / Contactors
GHMC.3.10GHMC.3.01GHMCP.3.10 (1)
GHMCP.3.01 (1)
GHMC.4.00GHMCP.4.00 (1)
GHMD.3.10GHMD.3.01GHMD.4.00
Invertitori / Reversers
GHMC.3.01/RGHMCP.3.01/R (1)
GHMD.3.10/R
Blocchi contatti ausiliariAuxiliary contact blocksGHTR11GHTR02GHTR40GHTR22
A.C.D.C.
A.C.
Caratteristiche tecnicheTechnical data
Contattori ausiliariAuxiliary contactorsGHMR.22GHMR.31GHMR.40
GHMRP.22GHMRP.31GHMRP.40
MINI - CONTATTORIMINI CONTACTORS
1-54
1