improved iaq & hvac performance

4
The Leader in UV-C Disinfection and HVAC Efficiency Improved IAQ & HVAC Performance Airports Restaurants Health Clubs Places of Worship Healthcare Offices Hospitality Schools

Upload: others

Post on 09-Jan-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Improved IAQ & HVAC Performance

The Leader in UV-C Disinfection and HVAC Efficiency

Improved IAQ & HVAC Performance

AirportsRestaurants Health ClubsPlaces of Worship

Healthcare Offices Hospitality Schools

Page 2: Improved IAQ & HVAC Performance

The RLM Xtreme’s unique lamp-scissoring design maximizes 360-degree UV-C output to disinfect coils and inactivate mold, bacteria, viruses and other pathogens in demanding and

high-volume HVAC environments.Forget end-to-end fixture constraints and eliminate the cost to stock multiple fixtures and lamp lengths.

EASY-TO-INSTALL, UP TO TWICE AS POWERFUL, the market-leading RLM Xtreme™ fixtureless UV-C lamp system is one of the most effective germicidal HVAC solutions available today.

HIGHEST REDUCTION OF INFECTIOUS MICROBES

APPLICATION: DUCT MOUNTED AIRSTREAM DISINFECTION/IAQ

LOCATION: AHU’s, RTU’s and HVAC ducts

PURPOSE: Inactivate airborne viruses, mycoplasma, bacteria and fungi “on-the-fly” in air supply or return ductwork.

BENEFITS: • Destroy up to 99+% of pathogens • Inactivate microbes in <1 second • Neutralize microbial contaminants that

impede HVAC efficiency • Mitigate disease transmission • No VOCs, chemicals or Ozone

AIR HANDLER COIL EFFICIENCY AND/OR AIRSTREAM DISINFECTION

Air Handler, split systems, and packaged heating and air systems, fan coils, etc.

Destroy mold and microbial growth on HVAC coils, air filters, ducts and drain pans.

• Increase cooling capacity and airflow • Boost heat transfer efficiency up to 14.5% • Decrease HVAC energy use up to 20% • Inactivate up to 30% of airborne pathogens • No VOCs, chemicals or Ozone

UV vertical lamp supports(12" off coil)Cooling coil

x2 stacked

UV SafePrefilter

UV downstream of coil for coil maintenance

UV upstream of coil for airstream disinfection

Fans

Airflow

UV Lamp Placement Options

Page 3: Improved IAQ & HVAC Performance

BEST-IN-CLASS DESIGNMaximum Output 360-degree high-output lamp generates up to twice the UV-C energy as conventional fixtured lamp systems.

Quick & Easy Installation Flexible framing kits help speed installs and include all components needed to properly mount UV fixtures.

Unlimited Configurations Overlapping lamps increases germicidal energy levels and reduces the cost to stock multiple lamp lengths.

Certified Safe Independently tested and verified to meet UL-2998 zero-Ozone.

Everything In One Package Order the RLM Xtreme as an “All-in-One” package that ships with everything you need from a single source.

Shatterproof Lamps All RLM Xtreme Lamps are protected with EncapsuLamp™, a safety sleeve (FEP Coating) that guards against accidental lamp breakage and AHU downtime.

Remote Monitoring Lamp and power supply status can be observed via a CU2™ sensor at the fixture or connected to a building management system using the UVRepeat™.

RLM XTREME™ SERIES BY-THE-NUMBERS

200%more UV-C output than fixtured lamp systems

Industry’s easiest to install and maintain

Certified UL-2998 Zero-Ozone Emissions

from Air Cleaners

A

B

C

D

E

A

C

B

D

E

Page 4: Improved IAQ & HVAC Performance

RLM XTREME™ PRODUCT SPECIFICATIONSCONSTRUCTIONRLM XTREME fixtureless UV-C lamp systems are factory-assembled and tested. They consist of a power supply and housing, wiring, ultraviolet lamp(s) featuring an FEP/EncapsuLamp™ protective coating, lamp plug and lamp holder.

POWER SUPPLY HOUSINGS are NEMA 2/IP11 compliant, constructed of powder coated 20ga galvanized steel and designed to facilitate NEC style power supply installations outside of plenums.

POWER SUPPLIES are high-efficiency electronic types matched to the lamp and designed to maximize UV-C production, lamp/irradiance, energy efficiency and reliability. They are UL and CSA Listed, 120-277V, 50/60 Hz, type 1, high-power factor, electronic rapid-start types with overload and end-of-lamp-life circuit protection, and sound rating A.

LAMP PLUG & HOLDER are UL listed, 4-pin SE type capable of accommodating a single-ended lamp. The Holder is constructed of UV-resistant materials and designed to connect the Lamp to the Plug, Holder and Loom to protect against electrical shock, moisture and separation.

LAMP LOOM is protected within a stainless steel flexible metal conduit to prevent UV-C degradation.

LAMPS are T5 diameter with EncapsuLamp, high-output single-ended 4-pin types that produce broadband UV-C at 253.7 nm. Useful lamp life is 9,000 hours with no more than a 15% output loss.

LAMP HOLSTERS™ are dual type and permanently affixed within the irradiated cavity. They are constructed of UV-C-resistant materials and provide maximum flexibility in lamp positioning, removal and fastening strength, and support two lamps each.

INDEPENDENT TESTING — Fixtures have been independently tested to UL-ABQK (pending), and verified ozone-free and meet UL-2998 Ozone concentration limits of less than 0.005 ppm. Intertek 104351693CRT-001d.

PRODUCT RLM XTREME

Electrical For electrical, use only 120-277V 50/60Hz, 1P

UV-C Output >420 µW/cm² at 1 Meter

Lamps High Output T5 single-ended, 4-pin

Lamp Holder/Wiring Loom

UL listed LampHolder with stainless steel flexible conduit

Certifications UL-2998; ETL listed per UL-ABQK (pending)

Irradiance 360° distribution — highest UV-C fluence available

Warranty 5-year power supply

©2021 UV Resources 55000525-1 REV B 09/22/21

Box 800370 I Santa Clarita, CA 91380-0370 877.884.4822 I UVResources.com

The Leader in UV-C Disinfection and HVAC Efficiency

ASHRAE 185.1

Airstream

5017711

Conf. to UL Std.: 1598, UL-2998; UL-1598(ABQK)

Cert. To CSA Std.: C22.2#250.0