Under Cabinet LED Flexible Light Strip Kit NFLSK-x300X3-UC Instruction Sheet Part Number: Parts Included Important: Read all instructions prior to installation. Pre-test & Configure Remove strip from reel and make connections to power supply and dimmer (see “Method 1” diagram). Briefly turn on strip using dimmer power button to ensure proper operation of the strip, power supply, dimmer, and remote. Layout strip on counter below cabinets, hold strips up under cabinets to determine lengths of strip segments needed for your installation. See below for cutting instructions. Connect all strip segments using appropriate length connectors, see “Connecting Strips” section and “General Diagram” for guides. Connect strip. Connect strip assembly to power supply to ensure all segments are connected properly, then remove power. Ensure all installation surfaces are clean and dry. Begin to remove strip’s backing while adhering to bottom front edge of cabinets for optimal illumination. Press firmly to secure strips to surface. Route strip interconnectors under cabinet seams, windows, and other spaces between cabinets. Attach dimmer and power supply to desired location using included foam tape. Cutting Cut strips to appropiate length using scissors on lines indicated with scissor icon. Strip can only be cut on these lines, which are spaced every 3 LEDs. + - Light Strip Dimmer (MCBRF-15A) Pigtail CPS Power Adapter Cable (CPS-PT) Power Supply + - Light Strip Female Terminal Screw Adapter (CPS-F2ST) Power Supply + - (Method 2) Without Dimmer + - Light Strip CPS Adapter Cable Clamp (NFLS10-2CHCPS) Power Supply + - (Method 3) Without Dimmer Instructions (Method 1) With Dimmer Connecting Strips Note: Dimmer must be used between the light strip and power supply. + - + - + - + - + - + - Gently pull out locking tab on face of Flexible Light Strip Interconnect (NFLS10-2CSH) Insert strip firmly into Interconnect making sure the polarity is correct by lining up the + symbol on the strip with the white wire on the connector. Return the locking tab to the closed position on the Interconnect by pushing back in. 1. 2. 3. Troubleshooting Tips: If the light strip does not light up, check that the polairty is correct. + symbol connecting to + symbol on all segments. Make sure strips are fully inserted in clamp-on connectors. + - + - 1 - 16.5’ (5m) LED Flexible Light Strip (NFLS-x300X3-UC) 1 - Single Color LED Controller - Wireless RF Remote (MCBRF-15A) 1 - 12VDC 60W Desktop Power Supply (TPZ-1200500A2) 1 - Female Terminal Screw Adapter (CPS-F2ST) 1 - Pigtail CPS Power Adapter Cable (CPS-PT) 2 - CPS Adapter Cable Clamp-On (NFLS10-2CHCPS) 4 - Flexible Light Strip Interconnect (NFLS10-2CSH) 3 - Solderless Clamp-On Pigtail Adapter (NFLS10-2CPTH) 1 - LC2 Male Power Connector Pigtail (LC2M-PT) 1 - LC2 Female Power Connector Pigtal (LC2F-PT) 10 - 22-16 AWG Grey Wire Nuts (WN-2216) 1 - 8’ Length 24 AWG Two Conductor Power Wire (WP24-2) 8 - Double-Sided Foam Pads (3M-FTP) If your installation requires additional parts, visit superbrightleds.com and enter the part number above in the search box. 5 yr WARRANTY 4400 Earth City Expy St. Louis, MO 63045 + - + - + - + - OUTPUT INPUT + - + -

Upload: others

Post on 10-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Important: Read all instructions prior to installation ...Instruction Sheet Part Number: Parts Included Important: Read all instructions prior to installation. Pre-test & Confi gure

Under Cabinet LED Flexible Light Strip Kit

NFLSK-x300X3-UC

Instruction SheetPart Number:

Parts Included

Important: Read all instructions prior to installation.

Pre-test & Confi gureRemove strip from reel and make connections to power supply and dimmer (see “Method 1” diagram). Briefl y turn on strip using dimmer power button to ensure proper operation of the strip, power supply, dimmer, and remote.

Layout strip on counter below cabinets, hold strips up under cabinets to determine lengths of strip segments needed for your installation. See below for cutting instructions.

Connect all strip segments using appropriate length connectors, see “Connecting Strips” section and “General Diagram” for guides. Connect strip. Connect strip assembly to power supply to ensure all segments are connected properly, then remove power.

Ensure all installation surfaces are clean and dry.

Begin to remove strip’s backing while adhering to bottom front edge of cabinets for optimal illumination. Press fi rmly to secure strips to surface. Route strip interconnectors under cabinet seams, windows, and other spaces between cabinets. Attach dimmer and power supply to desired location using included foam tape.

CuttingCut strips to appropiate length using scissors on lines indicated with scissor icon. Strip can only be cut on these lines, which are spaced every 3 LEDs.

+-

Light StripDimmer

(MCBRF-15A)

Pigtail CPS Power Adapter Cable(CPS-PT)

Power Supply

+-

Light Strip

Female Terminal Screw Adapter(CPS-F2ST)

Power Supply

+-

(Method 2) Without Dimmer

+-Light Strip

CPS Adapter Cable Clamp (NFLS10-2CHCPS)

Power Supply

+-

(Method 3) Without Dimmer

Instructions

(Method 1) With Dimmer

Connecting Strips

Note: Dimmer must be used between the light strip and power supply.

+

-

+

-

+

-

+

-

+

-

+

-

Gently pull out locking tab on face of Flexible Light Strip Interconnect (NFLS10-2CSH)

Insert strip fi rmly into Interconnect making sure the polarity is correct by lining up the + symbol on the strip with the white wire on the connector.

Return the locking tab to the closed position on the Interconnect by pushing back in.

1.

2.

3.

Troubleshooting Tips: If the light strip does not light up, check that the polairty is correct. + symbol connecting to + symbol on all segments. Make sure strips are fully inserted in clamp-on connectors.

+-

+-

1 - 16.5’ (5m) LED Flexible Light Strip (NFLS-x300X3-UC)

1 - Single Color LED Controller - Wireless RF Remote (MCBRF-15A)

1 - 12VDC 60W Desktop Power Supply (TPZ-1200500A2)

1 - Female Terminal Screw Adapter (CPS-F2ST)1 - Pigtail CPS Power Adapter Cable (CPS-PT)

2 - CPS Adapter Cable Clamp-On (NFLS10-2CHCPS)

4 - Flexible Light Strip Interconnect (NFLS10-2CSH)

3 - Solderless Clamp-On Pigtail Adapter (NFLS10-2CPTH)

1 - LC2 Male Power Connector Pigtail (LC2M-PT)

1 - LC2 Female Power Connector Pigtal (LC2F-PT)

10 - 22-16 AWG Grey Wire Nuts (WN-2216)

1 - 8’ Length 24 AWG Two Conductor Power Wire (WP24-2)

8 - Double-Sided Foam Pads (3M-FTP)If your installation requires additional parts, visit superbrightleds.com and enter the part number above in the search box.

5yrWARRANTY

4400 Earth City ExpySt. Louis, MO 63045

+

-

+-

+

-

+

-

OU

TPU

T

INPU

T+- +-

Page 2: Important: Read all instructions prior to installation ...Instruction Sheet Part Number: Parts Included Important: Read all instructions prior to installation. Pre-test & Confi gure

+

-

+

-

+

-

+

-

+

-

+

-

Light Strip (with stock female LC2 Connector)

Dimmer

Pigtail CPS Power Adapter Cable

+

-

+

-

+

-

Light Strip (with stock female LC2 Connector)

Power Supply

+ -

+ -

+ -+ -

+ -

+ -

+ -

+ -

Solderless Clamp On Pigtail Adapter

Ligh

t Stri

pLi

ght S

trip

Sold

erle

ss C

lam

p O

n Pi

gtai

l Ada

pter

Sold

erle

ss C

lam

p O

n Pi

gtai

l Ada

pter

Interconnect

8’ P

ower

Wire

(cut

to s

ize)

8’ Power Wire(cut to size)

+

-

+

-

+

-

+

-

+

-

+

-

Bottom View of Cabinet

Cabinet SeamsCabinet Lip Flat Bottom of Cabinet

Light Strip Light Strip

Interconnect

Note: This configuration is for over-the-stove microwave’s that have above cabinet storage with an existing outlet as a power source for the power supply. Wiring may vary based on cabinet configuration and outlet availability.

General Diagram

DO NOT connect LED strip directly to 120V AC power. This kit requires a 12V DC Adapter (included power supply) to be powered.DO NOT connect more than one 16.5’ section of light strips to the included power supply. Overloading the included power supply may cause overheating, shorting, and possibly fire.Be sure the power supply is not plugged into an outlet before connecting or disconnecting any of the kits components.DO NOT expose the light strip to direct or indirect moisture.Always observe proper polarity when connecting power and load.

Safety

866-590-3533 [email protected]

Note: If not using the Dimmer, see the front of this sheet for additional options for connecting to the power supply.

Female Terminal Screw Adapter (CPS-F2ST)

Flexible Light Strip Interconnect (NFLS10-2CSH)

LC2 Female Power Connector Pigtail (LC2F-PT)

CPS Adapter Cable Clamp (NFLS10-2CHCPS)

Solderless Clamp-On Pigtail Adapter(NFLS10-2CPTH)

Pigtail CPS Power Adapter Cable (CPS-PT)

LC2 Male Power Connector Pigtail (LC2M-PT)

+-

+ -

+-+-

OUTPUT

INPUT

+-+-