implementation of structural health monitoring system for live monitoring of the cable forces at...
TRANSCRIPT
![Page 1: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/1.jpg)
ByRajesh Prasad
Executive Director (Metro)Rail Vikas Nigam Limited
Implementation of Structural Health Monitoring System for live Monitoring of the Cable Forces
at Barddhaman ROB
![Page 2: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/2.jpg)
Good Physique
Regular Check ups
Preventive Measures & Medicines
Proper & Timely Cure & Restoration
A KEY TO LONG HEALTH LIFE OF MAN/STRUCTURE
Good Construction
Regular Inspections
Preventive Measures & Materials
Proper & Timely Repairs & Restoration
![Page 3: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/3.jpg)
SCOPE
• Why Structural Health Monitoring (SHM) required?
• How Structural Health Monitoring (SHM) function in this case?
• Methodology and Monitoring
• Output and Report generation
![Page 4: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/4.jpg)
SHM Consists of :-
• Design, Installation, Commissioning of SHMS• Operation, Maintenance, Data Recording,
Analysing and Reporting • Sensors to measure environmental and
structural response factors (F&T).• Signal acquisition solution, signal verification
and temperature adjustment, conversion of signal to digital format etc.
![Page 5: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/5.jpg)
• LARSA 4D model for design• Wind tunnel test• Use of precast RCC slabs to avoid scaffolding on deck• Composite structures for easier construction• Monolithic Back Span• Durable painting by epoxy based paint of Akzonobel• Erection scheme • LUSAS model for Construction Stage Analysis • Geometry Control during execution.• ROBO Control (Monitoring System) by M/s Mageba
FEATURES
![Page 6: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/6.jpg)
• For monitoring of the structural health of the bridge during its service life, 6 nos. of sensors have been installed on the stay cables subjected to maximum loads.
• The structural monitoring system issues alarm notification based on measurements by the on-structure instrumentation when pre-defined threshold values of structural loads are passed. Alarm criteria can be configured based on the structural design of the bridge
MONITORING SYSTEM (ROBO-CONTROL)
![Page 7: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/7.jpg)
• Long term monitoring system.
• Measurement of forces on stay cables.
• Compact Monitoring System.
• System sustenance to extreme conditions.
• Graphical data output in web interface with redundant data storage.
MAJOR COMPONENTS OF THE MONITORING SYSTEM
![Page 8: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/8.jpg)
SENSOR SCHEME
6(six) Nos. of sensors have been provided on the central pylon and extreme cables to monitor the forces on these critical cables which are subjected to maximum load. (10% of the total Cables need to be instrumented)
![Page 9: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/9.jpg)
Sensors Used SENSOR SCHEME
Electromagnetic Sensors
![Page 10: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/10.jpg)
Login Window
![Page 11: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/11.jpg)
First screen after login
![Page 12: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/12.jpg)
Cockpit display
![Page 13: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/13.jpg)
Cable Force and Temperature variation
![Page 14: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/14.jpg)
Live Force on Cable 7001
![Page 15: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/15.jpg)
Month wise variation
![Page 16: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/16.jpg)
• Placed inside protected box
• Round the clock running
• Data redundancy• Internet connection
required• Uninterrupted power
supply required
SYSTEM INSIDE THE PYLON
![Page 17: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/17.jpg)
Sensor tied up on the required strand Sensor on strand inside the AV tube
INSTALLATION
Onsite calibration Cabling left inside for future connections
![Page 18: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/18.jpg)
LOAD TEST
Cable No.
Observed Value Reference rangeReading during load test on 30.08.2016 (KN)
Lower limit (KN)
Upper limit (KN)
7001 55.7 33.39 77.287002 89.4 72.22 112.957003 75.4 69.71 109.447016 99.8 84.97 117.017017 78.1 50.99 91.217018 75.8 41.70 82.26
![Page 19: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/19.jpg)
LIVE MONITORING
Cable No.
Observed Value Reference range
Reading on 04.01.2017 (KN)
Lower limit (KN)
Upper limit (KN)
7001 55.6 33.39 77.28
7002 84.8 72.22 112.95
7003 83.4 69.71 109.44
7016 96.8 84.97 117.01
7017 73.5 50.99 91.21
7018 67.8 41.70 82.26
![Page 20: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/20.jpg)
LOAD TEST AND LIVE MONITORING SAMPLE
Cable No.
Observed Value Reference range
Reading during load test on 30.08.2016 (KN)
Reading on 07.01.2017 (KN)
Lower limit (KN)
Upper limit (KN)
7001 55.7 55.4 33.39 77.28
7002 89.4 84.6 72.22 112.95
7003 75.4 83.1 69.71 109.44
7016 99.8 96.8 84.97 117.01
7017 78.1 73.3 50.99 91.21
7018 75.8 67.3 41.70 82.26
![Page 21: Implementation of Structural Health Monitoring System for live monitoring of the cable forces at Barddhaman ROB Presented in International Technical Seminar Mumbai on 13.01.2017](https://reader031.vdocuments.us/reader031/viewer/2022030207/58a7926c1a28ab5f6c8b5819/html5/thumbnails/21.jpg)
Main benefits of Structural Health Monitoring: • Design Confirmation.• Safety of the structure.• Understanding behaviour
of structures at certain environmental conditions.
• Load Validation• Generation of time
dependent record of structure’s behaviour for further studies/decision.
CONCLUSION