© 2018 Synopsys, Inc. 1 Philippe YoungProfessor University of Exeter/ R and D Director Synopsys [email protected] Sept 05 2018 SWANSEA From 3D Images to Models Image Based Modelling: New Tools for Design and Analysis

Upload: others

Post on 18-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 1

Philippe Young– Professor University of Exeter/ R and D Director Synopsys

[email protected]

Sept 05 2018 SWANSEA

From 3D Images to Models –

Image Based Modelling:

New Tools for Design and Analysis

Page 2: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 2

Synopsys / Simpleware Intro

Page 3: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 3

Synopsys Today

FY17 Revenue: ~$2.7B Employees: >12,590 Years: 30+

• #1 electronic design automation

tools & services

• Broadest IP portfolio and

#1 interface, analog, embedded

memories & physical IP

• ‘Leader’ in Gartner’s Magic Quadrant

for application security testing

* Note: FY2018 guidance midpoint provided May 23, 2018

Canada

Chile

Japan303

S. Korea

Russia

China1,101

India2,544

Armenia

Israel

Europe1,471

Southeast Asia

Taiwan

USA4,580

Page 4: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 4

Simpleware Product Group

• Developers of high-end 3D image processing software

• Dedicated sales, support and service teams

• Global presence

• Customer base in life sciences, materials and

manufacturing applications

Japan

USA Germany

Southeast Asia

India

Brazil

China

Russia

UK

Page 5: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 5

What Does Image Based Modelling Offer

Medical/Clinical Industry Example:

Cut down on intra-operative time and improve clinical outcomes

• Based on pre-operative scans (e.g. CT, MRI)

• Take pre-operative virtual measurements

• Carry out virtual planning, e.g. resect bone, virtually check fit of

implant or stent within artery

• 3D print: obtain a physical model of femur or aorta for pre-

surgical planning/training

Page 6: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 6

What Does Image Based Modelling Offer

Industrial Reverse Engineering Example:

Inspect and validate as-built parts and compare to designs

• Take scans of a manufactured part, e.g. casting, ALM,

injection moulding…

• Non destructive 3D visualisation, e.g. to quantify defects

• Carry out geometric metrology, measurements, compare to

original CAD

• Facilitate simulation on as built or damaged part to check

still fit for purpose

Page 7: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 7

What Does Image Based Modelling Offer

Materials Industry Example:

Understand or improve performance of a microstructure,

e.g. filter, foam, composite, textile, soil, asphalt…

• Visualise internal structure from scans or synthetic data

• Calculate porosity, surface area, pore/particle distribution,

fibre orientation…

• Analyse network structures, e.g. centrelines, shortest

routes…

• Obtain homogenised material properties, e.g. effective

permeability, Young’s Modulus…

Page 8: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 8

Life Sciences Manufacturing & Materials

Simpleware Product Group

Customer Applications

Page 9: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 9

Applications in Life Sciences / Product Integration

Implants

Wearable

Electronics

Shoes /

Clothing

Protective

Gear

3D

Printing

Pre-Surgical

Planning

Physiological

Flows

Beauty & Care

Products

Page 10: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 10

Applications in Materials & Manufacturing

ALM /

3D Printing

Part

Inspection,

NDE/NDT

Reverse

Engineering

Metals

Composites

Soils

Asphalt

Foams

Filters

Page 11: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 11

Simpleware Software Solutions

Page 12: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 12

Simpleware Software Solutions

GUI-based High-end 3D Image Processing

Platform which provides Comprehensive

Range of Tools for:

• Visualization including animations

• Filtering and segmentation

• Measurement and quantification

• CAD and image integration

• 3D print, CAD and FEA/CFD model export

Page 13: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 13

Simpleware Software Solutions

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

3D Image Import

& Visualization

Page 14: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 14

Simpleware Software Solutions

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

3D Image Import

& Visualization

Page 15: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 15

Simpleware Software Solutions

3D Image Import

& Visualization

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

Page 16: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 16

Simpleware Software Solutions

3D Image Import

& Visualization

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

Page 17: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 17

Simpleware Software Solutions

3D Image Import

& Visualization

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

Page 18: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 18

Simpleware Software Solutions

3D Image Import

& Visualization

Segmentation

& Processing

Measurements

& Analysis

CAD & Image

Integration

Model

Generation

Page 19: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 19

Simpleware Image-based modelling workflow

Page 20: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 20

CT Scan of Part

Exported SlicesNorth Star Imaging

(NSI) CT Scanner

Content Courtesy of

Page 21: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 21

Image-based modelling workflowImport volume image data

Page 22: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 22

Image-based modelling workflowVoxel Grid Formed

Page 23: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 23

Image-based modelling workflowSegmentation of regions of interest

Page 24: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 24

Image-based modelling workflowCreate surface mesh (STL)

Page 25: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 25

Image-based modelling workflowCreate volumetric FE/CFD mesh

Page 26: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 26

Image-based modelling workflowNURBS generation – (IGES / STEP)

Page 27: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 27

Inspection workflows

Determining the “as-built” deviations from design

Page 28: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 28

Defect Quantification

Pore / Void / Particle analysis

Page 29: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 29

Automatic Reports

• Pre-set reports for pores and particles

• Customisable graphs

• Export to PDF, HTML or Clipboard

Page 30: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 30

Wall Thickness Analysis

• Analyse the thickness of any segmented mask or surface object

• Visualize results in 3D with a colour map to identify critical regions

• Probe the 3D model to inspect local results in more detail

• Statistics on the minimum, maximum and average thickness

Page 31: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 31

Shape Creation, Fitting and Analysis

• Tools for the creation and fitting of shapes, incl. planes, spheres, cylinders …

• Surface painting selection tools to easily and quickly identify regions of interest

• Obtain statistics and measurements for each shape or between shapes

Page 32: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 32

Snap Registration and Surface Deviation

• Snap registration offers an automatic alternative for registration of alike surfaces by landmarks

• Align scanned objects with the intended design part from STL/CAD

• Obtain visual feedback of differences and export many more statistics

CAD part

Scanned part

Page 33: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 33

Success stories

Inspection and simulation-based NDE

Page 34: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 34

Quality Control of ALM Aerospace Part

ELEMCA & CNES

Page 35: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 35

Highlights

• ALM part used for the TARANIS satellite was

analyzed to identify the location of porosities

within the material

• Simpleware software was used to generate

models for FEM to validate its structural

integration

• Results validated ALM method for comparing

CAD models and designed part, with space

mission applications

Quality Control of ALM Aerospace Part

ELEMCA, CNES

Page 36: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 36

Workflow

• X-ray CT data of aluminium part part used for

the TARANIS satellite were processed in

Simpleware ScanIP

Quality Control of ALM Aerospace Part

ELEMCA, CNES

Page 37: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 37

Workflow

• X-ray CT data of aluminium part part used for

the TARANIS satellite were processed in

Simpleware ScanIP

• The model was simulated in ANSYS to analyze

defects and compare scan data to previous

simulations based on idealized CAD data

Quality Control of ALM Aerospace Part

ELEMCA, CNES

Page 38: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 38

Workflow

• X-ray CT data of aluminium part part used for

the TARANIS satellite were processed in

Simpleware ScanIP

• The model was simulated in ANSYS to analyze

defects and compare scan data to previous

simulations based on idealized CAD data

• This workflow is useful for adding new levels of

quality control and analysis to AM processes

within the space industry. The part has been

successfully tested, and may now be

integrated into the space mission

Quality Control of ALM Aerospace Part

ELEMCA, CNES

Page 39: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 39

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 40: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 40

Highlights

• Total joint replacement can alleviate pain for

rheumatoid arthritis; surgery involves removing

the swollen joint tissue and replacing with an

off the shelf prosthetic

• For development of a patient-specific silicone

finger joint implant, Simpleware software was

used to segment CT scan data of the hand

• Workflow describes why and how to leverage

patient-specific anatomical data, non-linear

structural simulation, fatigue simulation and

shape optimization to enhance device design

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 41: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 41

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 42: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 42

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 43: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 43

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 44: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 44

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

• Implant design in CATIA into middle metacarpal and proximal phalange

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 45: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 45

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

• Implant design in CATIA into middle metacarpal and proximal phalange

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 46: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 46

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

• Implant design in CATIA into middle metacarpal and proximal phalange

• Non-linear finite element model created in Abaqus/CAE that included large deformation, contact and a 3rd order Ogden hyperelasticmaterial properties

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 47: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 47

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

• Implant design in CATIA into middle metacarpal and proximal phalange

• Non-linear finite element model created in Abaqus/CAE that included large deformation, contact and a 3rd order Ogden hyperelasticmaterial properties

• Durability analysis in fe-safe/Rubber to calculate maximal strain locations for 20°extension and 70° flexion

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 48: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 48

Workflow

• CT scan data of the right hand from the Visible Korean dataset used to segment bones from soft tissue in Simpleware ScanIP

• Implant design in CATIA into middle metacarpal and proximal phalange

• Non-linear finite element model created in Abaqus/CAE that included large deformation, contact and a 3rd order Ogden hyperelasticmaterial properties

• Durability analysis in fe-safe/Rubber to calculate maximal strain locations for 20°extension and 70° flexion

Giving Arthritis the Finger (Prosthetic Finger Joint)

Optimal Device, Endurica

Page 49: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 49

High-performance Computation

in Solid Oxide Fuel Cell Microstructures

Carnegie Mellon University

Page 50: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 50

Highlights

• High-performance methods using meshed 3D microstructures allows for quantification of local distributions of electrochemical properties from FIB-SEM data

• Simpleware software provides straightforward one-step conversion of microstructure data to meshes, speeding up previously time-consuming tasks for large meshes by using scripting

• Simulated local electrochemical performance throughout microstructure can provide insight into electrode degradation and failure behavior

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Carnegie Mellon University

Page 51: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 51

Workflow

• Electrode microstructures obtained using Xe-plasma FIB-SEM serial sectioning to capture length scales on the order of 100-200 μm

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Carnegie Mellon University

Page 52: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 52

Workflow

• Electrode microstructures obtained using Xe-plasma FIB-SEM serial sectioning to capture length scales on the order of 100-200 μm

• Simpleware software used to convert 3D scan data into microstructural, multi-domain and simulation-ready FE meshes. These models preserve the complex surface morphologies in three-phase SOFC electrodes

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Cathode

(3-phase)

Electrolyte

(1-phase)

Carnegie Mellon University

Page 53: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 53

Workflow

• Electrode microstructures obtained using Xe-plasma FIB-SEM serial sectioning to capture length scales on the order of 100-200 μm

• Simpleware software used to convert 3D scan data into microstructural, multi-domain and simulation-ready FE meshes. These models preserve the complex surface morphologies in three-phase SOFC electrodes

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Large-scale meshing:

30 x 30 x 10 [μm], 130 million mesh elements

Carnegie Mellon University

Page 54: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 54

Workflow

• Electrode microstructures obtained using Xe-plasma FIB-SEM serial sectioning to capture length scales on the order of 100-200 μm

• Simpleware software used to convert 3D scan data into microstructural, multi-domain and simulation-ready FE meshes. These models preserve the complex surface morphologies in three-phase SOFC electrodes

• High-performance simulations produced a collection of computed scalar or vector fields of electrochemical variables. Results showed promising insights into the distribution of local electrochemical parameters that can aid future research into SOFC performance

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Carnegie Mellon University

Page 55: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 55

Workflow

• Electrode microstructures obtained using Xe-plasma FIB-SEM serial sectioning to capture length scales on the order of 100-200 μm

• Simpleware software used to convert 3D scan data into microstructural, multi-domain and simulation-ready FE meshes. These models preserve the complex surface morphologies in three-phase SOFC electrodes

• High-performance simulations produced a collection of computed scalar or vector fields of electrochemical variables. Results showed promising insights into the distribution of local electrochemical parameters that can aid future research into SOFC performance

High-performance Computation

in Solid Oxide Fuel Cell Microstructure

Carnegie Mellon University

Page 56: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 56

Inspecting Deviation from Design

in Manufactured Part

North Star Imaging, Ansys, MOOG

Page 57: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 57

Highlights

• Optimizing the design of an internal test

manifold for a specific material and hydraulic

configuration

• Simpleware software 3D image processing

enabled visualization of defects, and

comparison of the as-built part from the original

CAD

• Simulation of maximum principal stress in

ANSYS. The workflow enabled MOOG to

quantify the fitness-for-purpose of the part and

evaluate performance uncertainty

Inspecting Deviation from Design in Manufactured Part

North Star Imaging, Ansys, MOOG

Page 58: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 58

Workflow

• CT scan data from NSI imported into

Simpleware software. Visualization of pores,

cracks and residual powder

Inspecting Deviation from Design in Manufactured Part

North Star Imaging, Ansys, MOOG

Page 59: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 59

Workflow

• CT scan data from NSI imported into

Simpleware software. Visualization of pores,

cracks and residual powder

• Simpleware software used to import original

CAD and compare with as-built part to identify

geometric deviations, for example in part

porosity

Inspecting Deviation from Design in Manufactured Part

North Star Imaging, Ansys, MOOG

Page 60: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 60

Workflow

• CT scan data from NSI imported into

Simpleware software. Visualization of pores,

cracks and residual powder

• Simpleware software used to import original

CAD and compare with as-built part to identify

geometric deviations, for example in part

porosity

• Simulation results in Ansys showed that

between the CAD and image-based model

there was a 23.18% increase in maximum

principal stress, likely due to cracks and pores

in the as-built geometry

Inspecting Deviation from Design in Manufactured Part

North Star Imaging, Ansys, MOOG

Page 61: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 61

Simpleware Human Body Models

Page 62: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 62

Simpleware Human Body Models

• To Design Better Products:

(e-wearables, shoes, sports clothing, helmets)

Currently designers and engineers of products that

interact with the human body make limited use of

anatomically correct CAD/CAE models to analyze

their performance in use.

• Provision of Off-the-shelf or Fully-customized

Models for:

– 3D printing / ALM (STL)

– CAD (NURBS)

– Simulation (FE and CFD meshes)

Page 63: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 63

Simpleware Human Body Models

Our Datasets:

• Large collection of anatomical datasets from high-resolution MRI and CT scans

• Models offer outstanding levels of detail and geometrical accuracy

• Select generic models or configure models to your requirements

• Models can be customized to combine CAD with image data

• Scans and models can also be commissioned

Page 64: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 64

Simpleware Services

Page 65: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

© 2018 Synopsys, Inc. 65

Simpleware Services

• Consultancy Services:

– Image processing, segmentation, analysis and animations

– Model and mesh generation

– Scanning and 3D printing facilities

• Customized Script, Plug-ins and Software Development:

– Get the best from the software’s functionalities and beyond

– Develop standalone personalized applications

• Software Training:

– Classroom training at local Synopsys offices or at your place of work

– Web-based training at your desk

Page 66: Image Based Modelling: New Tools for Design and Analysis€¦ · soft tissue in Simpleware ScanIP •Implant design in CATIA into middle metacarpal and proximal phalange •Non-linear

Thank You