ilca : in-line coagulation and adsorption for pre
TRANSCRIPT
![Page 1: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/1.jpg)
AMTA/AWWA © 1
ILCA®: In-line Coagulation and Adsorption for
Pre-treatment to Ceramic Microfiltration
R. Floris, H. Shorney-Darby, G. Galjaard, J. ZhengPWN Technologies, the Netherlands
![Page 2: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/2.jpg)
AMTA/AWWA © 2
Acknowledgements
• PWN Water Supply Company North-Holland, Netherlands
• Metawater, Japan
• RWB, Netherlands
• Het Waterlaboratorium, Netherlands
• Rob Kooijman PWNT, Netherlands
![Page 3: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/3.jpg)
AMTA/AWWA © 3
Background
![Page 4: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/4.jpg)
AMTA/AWWA © 4
Water source challenge
• most Provence below sea level
• Salty groundwater
• IJssel Lake only available
source
• dominantly fed by the river
Rhine
• under the influence of industry,
recreation, population
• high contamination level (delta
of Europe)
![Page 5: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/5.jpg)
AMTA/AWWA © 5
Water treatment line
Micro-sieves
IJssel Lake
Softening
Microstrainers
Ion Exchange
Ceramic Microfiltration
UV / H2O2
GAC
![Page 6: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/6.jpg)
AMTA/AWWA © 6
SIX® Suspended Ion Exchange
Micro-sieves
IJssel Lake
Softening
Microstrainers
SIX
Ceramic Microfiltration
UV / H2O2
GAC
• anion exchange resin (Lewatit S5218)
• concentration 18 ml/l
• contact time 30 minutes
• 30 g/l NaCl for regeneration
Performance evaluation SIX®-CeraMac® in comparison with
conventional pre-treatment techniques for surface water treatment
Galjaard, G., Martijn, B., Koreman, E., Bogosh, M., Malley, J.
DOI: 10.2166/wpt.2011.066
![Page 7: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/7.jpg)
AMTA/AWWA © 7
CeraMac® Ceramic Microfiltration
Micro-sieves
IJssel Lake
Softening
Microstrainers
SIX
Ceramic Microfiltration
UV / H2O2
GAC
Support layerSeparation
layer
2.5 mm
![Page 8: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/8.jpg)
AMTA/AWWA © 8
DOC removal
Micro-sieves
IJssel Lake
Softening
Microstrainers
Ion Exchange
Ceramic Microfiltration
UV / H2O2
GAC
![Page 9: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/9.jpg)
AMTA/AWWA © 9
Water quality changes
![Page 10: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/10.jpg)
AMTA/AWWA © 10
Additional step for fouling control
Micro-sieves
IJssel Lake
Softening
Microstrainers
Ion Exchange
Ceramic Microfiltration
UV / H2O2
GAC
Membrane pre-coating
Enhanced pre-coat engineering (EPCE) for micro- and ultrafiltration: The solution
for fouling?
Galjaard et al, Water Science and Technology: Water Supply 2001
• In-line coagulation
• Coagulant FeCl3• NaOH used for pH correction
• 6 ppm as Fe @ pH 8
![Page 11: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/11.jpg)
AMTA/AWWA © 11
Pre-coating mechanism model
![Page 12: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/12.jpg)
AMTA/AWWA © 12
Objectives
• Feasibility of pre-coating for additional fouling
control for ceramic microfiltration of surface water
• Comparison of conventional in-line coagulation
system with the ILCA®
![Page 13: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/13.jpg)
AMTA/AWWA © 13
In-line tank coagulation/flocculation
(TC)
• Volume 0.9 m3 (243 gal)
• Contact time 18 minutes
1. pH correction
2. coagulant dosing
3. flocculation(115 and 70 rpm)
1
23
coagulation tankSIX effluent
pH correction coagulant
Ceramic Microfiltration feed
![Page 14: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/14.jpg)
AMTA/AWWA © 14
In-Line Coagulation Adsorber
(ILCA®)
• Volume 0.18 m3 (48 gal)
• Contact time 3.6 minutes
• Plug-flow conditions
• Specifically designed
mixing inserts
Flow
[m3/h]
G-value
[s-1]
Contact
time [s]
GT value
[-]
3 65 223 14521
4 97 165 16005
5 135 132 17820
6 178 110 19580
6.5 200 102 20400
7 224 95 21280
![Page 15: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/15.jpg)
AMTA/AWWA © 15
Filtration conditions
• 1st phase: influence of filtration flux on membrane
operation at 90,150 and 200 l/m2/h (52.9, 88.2 and 118
g/ft2/d) [TC]
• 2nd phase: influence of filtration time @ 120 l/m2/h (70.6
g/ft2/d) [TC]
• 3rd phase: comparison of TC and ILCA systems @ 120
l/m2/h (70.6 g/ft2/d) and 60 minutes BW interval
![Page 16: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/16.jpg)
AMTA/AWWA © 16
Cleaning regime
• filtration load until backwash (BW)
– 50 l/m2 (1.23 g/ft2) 1st 2nd phase
– 120 l/m2 (2.95 g/ft2) 3rd phase
• chemically enhanced backwash (CEBW) after 19 BWs
– acidic CEBW with oxidant (pH 2.5, 100 mg/l H2O2)
– alkali CEBW (100 mg/l NaOCl)
![Page 17: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/17.jpg)
AMTA/AWWA © 17
Pre-coating influence on TMP
![Page 18: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/18.jpg)
AMTA/AWWA © 18
Filtration flux influence on TMP
![Page 19: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/19.jpg)
AMTA/AWWA © 19
Filtration time influence on TMP
120 l/m2/h (70.6 g/ft2/d)
![Page 20: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/20.jpg)
AMTA/AWWA © 20
TMP comparison
120 l/m2/h (70.6 g/ft2/d)
![Page 21: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/21.jpg)
AMTA/AWWA © 21
TMP comparison
120 l/m2/h (70.6 g/ft2/d)
![Page 22: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/22.jpg)
AMTA/AWWA © 22
TMP after CEBW
120 l/m2/h (70.6 g/ft2/d)
![Page 23: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/23.jpg)
AMTA/AWWA © 23
Month TMP development
120 l/m2/h (70.6 g/ft2/d)
![Page 24: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/24.jpg)
AMTA/AWWA © 24
DOC fractions
![Page 25: ILCA : In-line Coagulation and Adsorption for Pre](https://reader031.vdocuments.us/reader031/viewer/2022020705/61fc0cab6028cb156a21d237/html5/thumbnails/25.jpg)
AMTA/AWWA © 25
Conclusions
• Pre-coating is a good strategy for fouling control
by biopolymers during MF
• ILCA® is a good alternative to the conventional
TC systems
– It provides comparable ceramic MF operations
– Less footprint and shorter contact time
– Constant GT value independent of the flow
– Easy to scale-up
– No mechanical/moving parts (less maintenance)
– Can be combined with adsorbent