High Energy Savings
The 2.5 to 5.0 kw models deliver a high COP of g.g8.
This makes these models particularly appropriate forsituations requiring long periods of operation.
Soph isticated Appearance
with Flat Panel
The series'simple and stylish flat panelwith any interior decor. The 2.5 and 3.5the latest sleek design.
$' See page 4.
design harmoniseskW models feature
iir' 5tt Pages 3 and 5'
auiet Operation
The series offers low sound levels for both indoor andoutdoor units. The 2.5 kW indoor unit operates at 28 dB (A).
rt* See page 5.
Cleanliness
All units offer a range of clean features, including Air-Purifying Filter with Photocatalytic Deodorising Functionand Wipe-Clean Flat Panel. !* see page 5.
2
Split Type G series
A Refreshingly Simple DesignThe stylish flat panel design creates a simplicity and sophistication that enhances any interior space. All models from
design, providing a smooth, unified finish in every room in a home'
'i!t;rl
:!iiiiiiiiifit?r;:J
f
FT25135G
F
ilffi,*_ffi4;:,.:1ffi*
,r,16::,,,ttl::J
rgSEHb- *r1''##*sR r
FHEESIgEHHis,€sE**Hsi
ffiHFr
R25/35Gtili:;i
w;
t
"G FT25GV1 G IR25GV1 G2.62 kW 8,900 Btu/h
FT35GV1 G IR35GV1 G3.70 kW 12,7A0 Btu/h
-l #!
FT50/60G
r+,w1Ti'
RsOG R6OG
FT5OGV1G IR5OGV1Gi;* b.g kw 18,ogo Btu/h
FT6OGV1G IR6OGV1G6.6 kW 22,530 Btu/h
3
2.5 to 6.0 kW feature the sleek flat panel
All Models Earn 3 TicksThe 2.5 to 5.0 kW models provide a high COP of3.38. All models have received Singapore's 3 TickEnergy Label, which is the highest energy-efficiencyrating for non-inverter type air conditioners.
FT25GV1G FT35GV1G FT5OGV1G FT6OGV1G
coP 3.38 3.38 3.38 3.25
What is COP?An air conditioner's COP (Coefficient of Performance) indicates how efficiently the unit
/ uses energy. A higher COP means greater energy efficiency, lt also means lower'-\r' electricity consumption, so you save money.
COP(WA/VI =
What Is Energy Labeling?This scheme was introduced by Singapore's Ministryfor the Environment and Water Resources. Underthe scheme, non-inverter type air conditionerswith a cooling capacity of less than 17.6 kW mustcarry labels to indicate their energy-saving rating.This allows households to select more energy-efficient models and so reduce their electricity bills.
Edvr{1 t:r{9!nlglltn lvrll }ri [rrffiffi
Crdlirlg CaFqciiyi 2.6d lW DAlKll-{Spli!|rpa{rFo-inef,rter}nir{rftditio{1er R?5SVlC
ffiCmli!)g Capacity: 5.lt hvt D.a,iKlN
Slllittypeinqn-iflrerler)air€onditioler RsocvlG
ffiffirffiCoofingcapacityi 3.74kltl DAIKI!{Split t/pe {norjnvert€r} air4oodilioner R35Gv1 G
Tre!D<, id *cdrdasc€ w{h lSQ 5151Atul e'Ergy co4sr${ioa m! !3ry lmm HI cau}E
,.i*: j.lTr$iffi .T;1i..",,;1u,,
rnffi$ffrsgruCoolirgcap{Nity; €.59kyv DillKlNSplittyFeiodlinsderlaiHorrditisler R6SSvlC
T6bd in accordance wi& iSO 51 51ActlElenelgf c@6un8&n &y var! frcfr Ht €ults
for rrw ldornFliqft e}{ tF Aofrularp nede*, It+t.ffiffi4gev{S'r+:","+;'i;.:iS id.:r +mtsq+.fsffqi+;1..:r;.'i"'.1",:;,'.'
R6OG
Function ListModels
Functions
Split TypeFT
25135GFT
50/60G
o€=EOOFtFL
5ao
Power-Airflow DualFlaps
lffi wide-Anste Louvers
Vertical Auto-Swing(up and down)
'"r, ,,0= i Horizontal Auto-
LWJ Swing (teft and right)
lL*d -5
I
ffij 3-DAirlow
fa_
b9Fstrtsss
.,., , Programme Dry, " Function'il'a,
itu' Auto Fan Speed
([)()(l)c
E.!u
EgII rL.-o
C)
iffi-i New Powerful
'@; Operation
i*Gr Indoor Unit On/Offi€-i switch
oo(l).Ec(tr(l)
o
ri: Air-Purifvinq FilterlM I with Phoioc?talvticiiej Deodorising Function
iffil Wipe-Ctean Ftat[lz+g31 Panel
oLoEtr
m 24-Hour On/Offt\Ifl/l Timer
@ Nisht set Mode
#:t{rl.j Auto-Restart afterE i@j Power FailureL
t ##] Setf-Diagnosis with
f ief-i{i Digitat Disptay
-O iEd,J;i Anticorrosion Treatment
= I,;-,;-.,, of Outdoor Heat,-:"::ii:""..'.-. Exchanggr Fins
ffi#i#,{fffii
4
Features
Eaqy to Coordinate and Wde Range
Easy to CoordinateDaikin has always focused on creating sleek,modern air conditioners that coordinate smoothlywith any type of interior decor. This concept hastaken a major step forward with the versatilegrilleless flat panel design.
Quiet Sound LevelsFT25G offers a low sound levelindoor unit operation and 47 dBunit operation.
lndoor unit FT25GV1G FT35GV1G
Sound levels (L) 28 31
Outdoor unit H25GV1G R35G1/1G
Sound levels 47 48
of 28 dB (A) for(A) for outdoor
Unit: dB (A)
FT5OGV1G FT6OGV1G
35 38
RsOGVlG R6OGV1G
54 54
28 dB (A) ls So Quiet You Can
lndoor unit
Rustling of leaves Library
Pendulum of a wall clock
Even Hear:H:::""*
ffi:,jffi*Normal office
Based on "Examples of Sound Levels", Ministry of the Environment, Japan,November 12,2OO2
Air filterCatches dust
il,)'l*t,,,,it,@
Air-Purifying Filter withPhotocatalytic Deodorising FunctionTraps microscopic particles and even removes bacteria.
1II
I
J
Air-Puri$ing Filter with Photocatalytic Deodorising Function
Air-Purifying Filter with Photocatalytic DeodorisingFunction is able to trap microscopic particles andeven remove bacteria. This filter features a largeactive surface area that effectively cleans the highvolumes of air required to air-condition living rooms.The filter delivers consistent performance forapproximately 3 years if periodic maintenance is
performed.
Air-purifyingfunction
Photocatalyticdeodorisingfunction
This filter is not a medical device. Benefits such as the adsorptionand decomposition of bacteria are only effective for substancesthat are collected on and in direct contact with the Air-PurifyingFilter with Photocatalytic Deodorising Function.
Bacteria removal testTesting method: Dropping methodTestingorganisation: Japan Spinners lnspecting Foundation
Result ceftificate: No. 012553-1 and 01 2553-2
5
of Aldow Functlons
ffi Power-Airflow Dual Flaps Wide-Angle Louvers
\Vide-Angle Louvers
Power-Airflow Dual Flaps and Wide-Angle Louverswork in tandem to precisely control both verticaland horizontal airflow for distribution of air.
Power-Airflow Dual Flaps
Cool air slides off to reach the corner of theroom.
From a cornerto the centre
KKWW
Covers evena spacious room
ffi Vertical Auto-Swing (up ancl clown)
g Horizontal Auto-Swing (left ancl right)!i@ ltl
Wj 3-D AirflowVertical Auto-Swing automatically moves theflaps up and down and Horizonlal Auto-Swingautomatically moves the louvers to the left andright. 3-D Airflow combines Vertical andHorizontal Auto-Swing to circulate air to everypart of a room for uniform cooling of even largespaces.Horizontal Auto-Swing and 3-D Airflow are available for FT50/60G.
New Powerful OperationNew Powerful Operation boosts airflow tomaximum volume for a 2}-minute period. Afterthis, the unit automatically returns to itsprevious settings. This function is activated bypushing the POWERFUL button on the remotecontroller. So, for example, now when youcome home on a hot day, a powerful airflowwill always be right at your fingertips.
6
Features
kllable Functlons
Indoor Unit On/Otr SwitchThe unit can be conveniently started manuallyin the event the wireless remote controller is
misplaced or the wireless remote controllerbatteries are not charged. FT25/35G appearance
Cross section of anticorrosion-treated fin
Hydrophilic filmo ' Aluminium
...,,*,, I Corrosion-resistant
Sil. u'TresinEtMalfunction codes are shown on the digitaldisplay panel of the wireless remote controller forfast and easy maintenance.
Long piping length for flexibleFT50/60G supporls a piping length of up to 30metres to give flexibility during unit installation.This allows the outdoor unit to be placed on abalcony or where it can not be seen. lndoor unitscan also be installed where they do notcompromise the decor of a room.
7
lndoor Unit On/Off Switch
ffiAnticorrosion Treatment of Outdoor Heat Exchanger FinsThe outdoor unit's heat exchanger fins areprocessed using a special anticorrosiontreatment. The surface is covered with a thinacrylic resin layer to enhance the fins'resistance to acid rain and salt corrosion.A hydrophilic film layer also prevents rustcaused by the run off of water droplets.
Self-Diagnosis with Digital Display
unit placement
Piping connections for the outdoor unit are covered tomake them less conspicuous.
Heat exchanger fin
Max, piping length Max, height dif{erence
FT25l35G 25m 15 m
FTs0/60G 30m 15 m
Easy-to-use wireless remote controller
Wireless remote controller for FT25/35G
Sets room temperature
On/Off switch
Selects mode: {W @ ffi--.--- VerticalAuto-Swing p7;1
cooling, dry, fan-6'riif opdiaiiori (up and down) [5('J
Cancels On/Off Timer
@ 24-Hour On Timer
24-Hour Off Timerand Night Set Mode
New Powerful Operation
u'",1 Selects fan speed
\/
@m
Wireless remote controller for FT50/60G
Sets clock
Sets timer
Sets clock
Sets timer
I
&TgMP
3
Cancels On/Off Timer
@ 24-Hour On Timer
24-Hour Off Timerand Night Set Mode@m
Functions Dictionary
Comfortable Airflow
Power-Airflow Dual FlapsPower-Airflow Dual Flaps can flatten out during coolingoperation to deliver cool air to the corners of a room.
) See page 6
Wide-Angle LouversThe smoothly curved Wide-Angle Louvers provide wide
airflow coverage for effective cooling operation no matterwhere the indoor unit is placed in a room.) See page 6
Vertical Auto-Swing (up and down)This function automatically moves the flaps up and downto distribute air across a room.) See page 6
Horizontal Auto-Swing (left and right)Horizontal Auto-Swing automatically moves the louvres tothe left and right to cover a room with cool air.) See page 6
3-D AirflowThis function combines Verlical and Horizontal Auto-
Swing to circulate a cloud of cool air right to the corners ofeven large spaces.) See page 6
Lifestyle Convenience
New Powerful OperationNew Powerful Operation boosts airflow to maximumvolume for a 20-minute period. After this, the unitautomatically returns to its previous settings.) See page 6
lndoor Unit On/Off SwitchThe unit can be conveniently started manually in the
event the wireless remote controller is misplaced or thewireless remote controller batteries are not charged.) See page 7
Cleanliness
Air-Purifying Filter with PhotocatalyticDeodorising FunctionThis filter traps microscopic particles and even removesbacteria. lt can be used for up to 3 years,) See page 5
Wipe-Glean Flat PanelThe flat panel models can be cleaned with only the singlepass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.
Comfort Gontrol+[{xili{[ir+rl[i
-r" , Programme Dry Function. ' ' i ;, This function automatically reduces the level of humidity.l.!,,-,,,... .....,1
.,,::,,:;,;ft I Auto Fan Speed
n'i'i". , The microprocessor automatically controls fan speed to' ; 'i'' l1''r adjust the room temperature to the set temperature.
Timers
24-Hour On/Off TimerThis timer can be preset to start and stop at any timewithin a 24-hour period. The air conditioner is started/stopped simply by pressing the On/Off timer button onthe wireless remote controller.
Night Set ModePressing the Off timer button automatically selects NightSet Mode. This function prevents excessive cooling foryour pleasant sleep. Room temperature is raised by0.5 'C after 60 minutes for cooling operation.
Worry Free
Auto-Restart after Power FailureThe air conditioner memorises the settings for mode,airflow, temperature, etc., and automatically returns tothem when power is restored after a power failure.
Self-Diagnosis with Digital DisplayMalfunction codes are shown on the digital display panelof the wireless remote controller for fast and easymaintenance.) See page 7
Anticorrosion Treatment of Outdoor HeatExchanger FinsThe outdoor unit's heat exchanger fins are processedusing a special anticorrosion treatment. The surface iscovered with a thin acrylic resin layer to enhance the fins'resistance to acid rain and salt corrosion.) See page 7
II
I
i,I
I1*
9
Refer to the Function List on page 4 to check the functions offered by individual models.
Specifications and Options
Qrcmr*f,ffrm*$msruq# tr*d%*.%*.s s g%*fu&.fuA%Ps se#R
Model namelndoor unit FT25GV1G FT35GV1 G FT5OGV1 G FT6OGV1 G
Outdoor unit R25GV1G R35GV1G RSOGV1 G R6OGV1 G
CapacityKW 2.62 3.70 5.3 6.6
Btu/h 8.900 12.700 18.090 22.530Power supply 1 phase , 230 V, 50 HzRunninq current A 3.5 4.9 6.9 9.1Power consumption W 775 1 ,095 1.570 2.030coP wAru 3.38 3.25lndoor unit FT25GV1 G FT35GV1G FT5OGV1 G FT6OGV1 GFront panel colour White
Airflow rate (H)m3/min 9.6 9.9 18.0 18.5
cfm 339 350 635 653Fan speed 5 steps and automaticSound levels (H/L) dB (A) 36128 39/31 45135 48138Dimensions(HxWxD) mm 283 x 800 x 195 290x1,050x238Machine weiqht kq I 12Outdoor unit R25GV1G R35GV1G RsOGVl G R6OGV1 GCasino colour lvorV white
CompressorType Hermetically sealed rotary type
Motor output W 700 1 ,000 1,530 2,850Refriqerant charqe (R-22\ kq 0.82 1.22 1.85 2.0Sound levels dB (A) 47 48 54Dimensions(HxWxD) mm 550x765x285 735x825x300 770x900x320Machine weiqht kq 31 37 4B 62Operation range .CDB
19.4 to 46
Piping connectionsLiqu id
mms6.4
Gas s9.5 a12.7 a15.9Drain s1B.O
Max. piping lengthm
25 30Max. heiqht difference 15
\.9'
Measurement conditions1 . Cooling capacity is based on: indoor temp. 27 "CDB, 19 'CWB; outdoor temp. 35 'CDB; piping length 7.5 m.2. Sound levels are based on the temperature conditions in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual
operation as a result ol ambient conditions.
ffi *$S Bffi€*E eEF%. #tu#$J tRtu#ff Xh
g
lndoor'un',il
. Notes: *1 . A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
. j *2. The time clocks and other devices should be obtained locally.v *3. The air-purifying filter with photocatalytic deodorising lunction is a standard accessory. The filter should be replaced after approximately 3 years.
rlt:. I |a4.
5-room centralisedcontrollerKRC72
Air-purifying filter with photocatalyticdeodorising function without frameKAFg7O 444
lr'
i.
. .: " l::.:. j.$,-{:;s6,-.
Remote controller lossprevention with chainKKFg1 OA4
outdoof,uni,t
No. Item FT25|35G I rT50/60c1 5-room centralised controller KRC72
2 Wiring adaptor for time clocl</remote controller(Normal open pulse contacVnormal open contact)
KRP41 3AB1 S
3 Air-purifyinq filter with photocatalytic deodorisinq function without frame KAF970A44 I t< AF952A424 Remote controller loss prevention with chain KKFg1 OA4
Specifications are subject to change.
No. Kit name R25/35G R50/60G1 Air direction adiustment qrille KPW937A4 KPW945A42 Drain pluq KKP937A4
Note: *'1. One set includes 5 pieces for 5 units.
10
Warling o Daikin products are manufactured for export to numerous countries throughout the world. Prior topurchase, please confirm with your local authorised importer, distributor and/or retailer whether thisproduct conforms to the applicable standards, and is suitable for use, in lhe region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
o Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
lmproper installation can result in water or refrigeranl leakage, electrical shock, fire or explosion.
o Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
o Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
lf you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. lf the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. lf you need to installthe outdoor unit close to the sea shore, contact your local distributor.
0rganization:DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF
COMMERCIAL AIR CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT,
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT,
COMPRESSORS AN D VALVES.
ffiJQA-1452
0rganization:DAIKIN INDUSTRIES
(THATLAND) LTD.
Scope of Registration:THE DESI GN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR THEM
,,gGANlZAllpr,^\\.- 'r^
o$' ISO ou
a* 14001 2
-
zJAC$)sa^ *4w2, O'
" ryvdvf. ,,..rrri$'
EC99J2044
All of the Daikin Group's businessfacilities and subsidiaries in Japan
are certified under the lS0 14001
international standard forenvir0nment management.
Dealer E'AT'<T N I N DUST'R'ES, I:T D.Head Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg.,2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan
http ://www. dai ki n . com/g lobal_acl
@All rights reservedPrinted in Singapore 01l12l0)5 OX, P.C.
Specifications, designs and other content appearing in this brochure are current as ol January 2012 but subject to change without notice.